Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 61
Filter
1.
BMC Surg ; 24(1): 125, 2024 Apr 25.
Article in English | MEDLINE | ID: mdl-38664803

ABSTRACT

BACKGROUND: The ideal treatment of terrble triad injuries and whether fixation of coronoid process fractures is needed or not are still debated. Therefore, we aimed to investigate if terrible triad injuries necessitate coronoid fracture fixation and evaluate if non-fixation treatments have similar efficacies and outcomes as fixation-treatments in cases of terrible triad injuries. METHODS: From August 2011 to July 2020, 23 patients with acute terrible triad injuries without involvement of the anteromedial facet of the coronoid process were included to evaluate the postoperative clinical and radiological outcomes (minimum follow-up of 20 months). According to the preoperative height loss evaluation of the coronoid process and an intraoperative elbow stability test, seven patients underwent coronoid fracture fixation, and the other eight patients were treated conservatively. The elbow range of motion (ROM), Mayo Elbow Performance Score (MEPS), and modified Broberg-Morrey score were evaluated at the last follow-up. In addition, plain radiographs were reviewed to evaluate joint congruency, fracture union, heterotopic ossification, and the development of arthritic changes. RESULTS: At the last follow-up, the mean arcs of flexion-extension and supination-pronation values were 118.2° and 146.8° in the fixation group and 122.5° and 151.3° in the non-fixation group, respectively. The mean MEPSs were 96.4 in the fixation group (excellent, nine cases; good, tow cases) and 96.7 in the non-fixation group (excellent, ten cases; good, two cases). The mean modified Broberg-Morrey scores were 94.0 in the fixation group (excellent, sevev cases; good, four cases) and 94.0 in the non-fixation group (excellent, ten cases; good, tow cases). No statistically significant differences in clinical scores and ROM were identified between the two groups. However, the non-fixation group showed a significantly lower height loss of the coronoid process than the fixation group (36.3% versus 54.5%). CONCLUSIONS: There were no significant differences in clinical outcomes between the fixation and non-fixation groups in terrible triad injuries.


Subject(s)
Elbow Injuries , Elbow Joint , Fracture Fixation, Internal , Range of Motion, Articular , Ulna Fractures , Humans , Male , Adult , Female , Ulna Fractures/surgery , Ulna Fractures/diagnostic imaging , Middle Aged , Fracture Fixation, Internal/methods , Range of Motion, Articular/physiology , Elbow Joint/diagnostic imaging , Elbow Joint/physiopathology , Elbow Joint/surgery , Retrospective Studies , Young Adult , Treatment Outcome , Follow-Up Studies
2.
Sci Rep ; 14(1): 9821, 2024 Apr 29.
Article in English | MEDLINE | ID: mdl-38684728

ABSTRACT

Dimensionally stable anodes of titanium (Ti) metal coated with mixed metal oxides (MMO) are widely used in several electrochemical applications, especially chloro-alkali electrolysis. Herein, we deposited MMO coatings on Ti substrates in different compositions, namely, (60%RuO2-40%TiO2), (60%RuO2-30%TiO2-10%IrO2), and (60%RuO2-20%TiO2-15%IrO2-5%Ta2O5), where RuO2 has the same percentage ratio in all coatings. The aim was to use these electrodes for chlorine evolution reaction (CER) and oxygen evolution reaction (OER) applications. Electrochemical characterization of the coated samples was performed to identify the best Ti/MMO electrodes with the highest efficiencies among the various prepared combinations. The role of IrO2 and Ta2O5 in enhancing corrosion resistance and electrochemical efficacy was up for debate. Scanning electron microscope (SEM), energy dispersive spectroscopy (EDS), X-ray diffraction (XRD), and X-ray photoelectron spectroscopy (XPS) analyses were exploited to determine the surface morphology, chemical composition, crystallinity, surface composition, and chemical states of the acquired coatings. The differential scanning calorimetry (DSC) method was used to evaluate the apparent activation energy ( E a ) of the deposited MMO. Additionally, the electrochemical performance of our designed coatings was scrutinized by cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), a current on-off test, a CV stability test (ST), and an accelerated stability test (AST). Furthermore, linear sweep voltammetry (LSV) was incorporated to assess the catalytic efficacy of the prepared anodes toward the CER in a brine solution of pH 2 and the OER in 1 M H2SO4. It became clear that the CER and OER incurred almost the same potential value (1.1 V) on both Ti/RuO2-TiO2 and Ti/RuO2-TiO2-IrO2 electrodes. However, on the Ti/RuO2-TiO2-IrO2-Ta2O5 anode, there was a 0.2 V potential difference between the CER occurring at 1.1 V and the OER happening at 1.3 V.

3.
Chem Pharm Bull (Tokyo) ; 72(2): 190-199, 2024.
Article in English | MEDLINE | ID: mdl-38369345

ABSTRACT

A co-amorphous model drug was prepared by the spray-drying (SD) of probucol (PC) and atorvastatin calcium trihydrate salt (ATO) as low water solubility and co-former components, respectively. The physicochemical properties of the prepared samples were characterized by powder X-ray diffraction (PXRD) analysis, thermal analysis, Fourier transform infrared spectroscopy (FTIR), and dissolution tests. Stability tests were also conducted under a stress environment of 40 °C and 75% relative humidity. The results of PXRD measurements and thermal analysis suggested that PC and ATO form a co-amorphous system by SD. Thermal analysis also indicated an endothermic peak that followed an exotherm in amorphous PC and a physical mixture (PM) of amorphous PC and ATO; however, no endothermic peak was detected in the co-amorphous system. The dissolution profiles for PC in the co-amorphous sample composed of PC and ATO were improved compared to those for raw PC crystals or the PM. Stability tests indicated that the co-amorphous material formed by PC and ATO can be stored for 35 d without crystallization, whereas amorphous PC became crystallized within a day. Therefore, co-amorphization of PC and ATO prepared by SD is considered to be a useful method to improve the solubility of PC in water.


Subject(s)
Probucol , Water , Atorvastatin , Probucol/chemistry , Drug Stability , Crystallography, X-Ray , X-Ray Diffraction , Water/chemistry , Solubility , Spectroscopy, Fourier Transform Infrared , Calorimetry, Differential Scanning
4.
Foods ; 12(19)2023 Sep 27.
Article in English | MEDLINE | ID: mdl-37835236

ABSTRACT

Rapeseed oil is an important source of edible oil in the human diet and is also highly susceptible to oxidative deterioration. It has been demonstrated that rosemary extract (RE) can increase the oxidative stability of oils. In this work, the antioxidant capacity of rapeseed oil after the addition of RE during storage and the optimum addition of RE in rapeseed oil were investigated. Oxidative stability evaluation results demonstrate that the shelf life of rapeseed oil with the incorporation of 100 mg/kg of RE was equivalent to that with the addition of 50 mg/kg of tert-butyl hydroxyquinone (TBHQ). Storage test analysis results show that RE remarkably delayed the oxidation of rapeseed oil when the storage container was unsealed. The optimum amount of RE as an addition was 50-200 mg/kg under room temperature storage, while it was 150 mg/kg under Schaal oven storage. The antioxidant capacity of rapeseed oil with 50 mg/kg of RE added was remarkably higher than that with 50 mg/kg of TBHQ added after 20 d of storage, according to the Schaal oven test. Additionally, the addition of RE delayed the degradation of endogenous α-tocopherol in rapeseed oil. This study comprehensively evaluated the antioxidant properties of rapeseed oil when RE was added and it provides a new strategy for establishing healthy, nutritious, and safe oil preservation measures.

5.
Int J Sports Phys Ther ; 18(5): 1166-1175, 2023.
Article in English | MEDLINE | ID: mdl-37795324

ABSTRACT

Background: While there have been reliability studies conducted on several upper extremity functional performance tests (UEFPT), there are several complicating factors that inhibit the ability to draw definitive consensus about the reliability of the tests in both females and males. Having reliability estimates for UEFPT in the same cohort facilitates direct comparison of their relative and absolute reliability. Purpose: To establish the test-retest reliability of the closed kinetic chain upper extremity stability test (CKCUEST), seated medicine ball chest pass test (SMBCPT) and hands-release push-up test (HRPUT) in a cohort of males and females with a history of non-overhead sport participation. A secondary purpose was to examine the associations between the three UEFPT. Study Design: Test-retest reliability, single cohort study. Methods: Forty adults (20 females, 20 males) with a history of non-overhead sport participation completed three UEFPT during two data collection sessions three to seven days apart. Measures of systematic bias, absolute reliability and relative reliability were computed between the sessions. Additionally, correlational analyses were conducted between the three UEFPT. Results: Only the UECKCST (both sexes) demonstrated significant (p≤ 0.003) second session performance improvements. All three tests exhibited excellent relative reliability (intraclass correlational coefficients ≥ 0.823) and except for the HRPUT in males, coefficients of variation were all below 8.8%. Except for a significant relationship (r=.691, p=0.001) between the UECKCST and SMBCPT for the females there were no other associations between the three UEFPT. Conclusion: All three UEFPT demonstrated sufficient reliability. Thus, all three assessments can be used for serial assessments to progress a patient through rehabilitation as well as contribute to the criteria used in making return to sport decisions. Level of Evidence: 3.

6.
Exp Gerontol ; 182: 112302, 2023 Oct 15.
Article in English | MEDLINE | ID: mdl-37776986

ABSTRACT

BACKGROUND: Cognitive decline in older adults may affect balance function, but the relationship between the two is not fully understood, especially in the early stages of cognitive impairment. Mild to moderate cognitive impairment can be assessed with the Montreal Cognitive Assessment (MOCA). AIM: This study quantitatively analyzed balance function in older adults with mild to moderate cognitive impairment using computerized dynamic posturography (CDP) testing. METHODS: 248 older patients were divided into a cognitive impaired group (MOCA <26, n = 126) and a normal group (MOCA ≥26, n = 122) based on the Montreal Cognitive Assessment (MOCA) Beijing Version. Patients underwent CDP testing, which included the sensory organization test (SOT) and the limits of stability test (LOS). RESULTS: The cognitive impaired group had significantly lower SOT composite and visual scores, as well as reaction time (RT), movement velocity (MVL), endpoint excursion (EPE), maximum excursion (MXE), and directional control (DCL) of the LOS test. Binary logistic regression analysis revealed that RT and MXE were independent factors significantly associated with MOCA, even after adjustment for age and sex. CONCLUSIONS: Older patients with mild to moderate cognitive impairment may have reduced sensory integration and balance stability limits, mainly manifested as prolonged motor reaction time and shortened maximum movement distance.

7.
J Clin Med ; 12(15)2023 Aug 02.
Article in English | MEDLINE | ID: mdl-37568490

ABSTRACT

The aim of this prospective study is to investigate implant stability and the reliability of different measuring devices according to implant placement site and duration in patients aged over 65 years. The study evaluated 60 implants (diameter: 3.5/4.0/4.5/5.0 mm and length: 8.5/10.0/11.5 mm) in 60 patients aged ≥ 65 years. The implant placement sites were divided into six evenly distributed sections (n = 10), i.e., maxillary right-posterior, A; maxillary anterior, B; maxillary left-posterior, C; mandibular right-posterior, D; mandibular anterior, E; mandibular left-posterior, F. Participants visited the hospital six times: implant surgery, 1V; stitch removal, 2V; 1-month follow-up, 3V; 2-month follow-up, 4V; before final restoration delivery, 5V; and after final restoration delivery, 6V. The implant stability was evaluated with the Osstell Mentor (ISQ), Periotest M (PTV), and Anycheck (IST). The mean values of ISQ, PTV, and IST were analyzed (α = 0.05). ISQ, PTV, and IST results of 4V and 5V were significantly higher than those of 1V (p < 0.05). The lowest ISQ results occurred in the E location at 4V and 5V (p < 0.05). In all mandibular locations, IST results of 6V were significantly higher than those of 1V, 2V, 3V, and 4V (p < 0.05). ISQ results were negatively correlated with PTV and positively correlated with IST, and PTV was negatively correlated with IST. By considering various factors affecting the stability of the implant, it is necessary to determine the appropriate implant load application time. This could help increase the implant success rate in elderly patients. And as a diagnostic device for implant stability and the evaluation of osseointegration in elderly patients, Anycheck was also able to prove its relative reliability compared to Osstell ISQ Mentor and Periotest M.

8.
J Orthop Surg Res ; 18(1): 489, 2023 Jul 10.
Article in English | MEDLINE | ID: mdl-37424003

ABSTRACT

OBJECTIVE: Despite the studies that have investigated the reliability of Upper Extremity Functional Tests(UEFTs), the reliability of Closed Kinetic Chain Upper Extremity Stability(CKCUES), Seated Medicine Ball Throw(SMBT), push-up(PU) and Unilateral Seated Shot Put(USSP) tests in overhead athletes has yet to be assessed. The objective of this study was to determine both the relative and absolute test-retest reliability of the four UEFTs in female overhead athletes. METHODS: Twenty-nine female overhead athletes (age: 26.6 ± 5.29 years) underwent the four UEFTs twice within a three- day interval. The upper limb stability was assessed through PU and CKCUES tests, while the power was assessed though SMBT and USSP tests. The Intraclass Correlation of Coefficient (ICC) was applied to assess the relative reliability. Absolute reliability was determined by calculating the Standard Error of Measurement (SEM) and the Minimal Detectable Change (MDC). Furthermore, Bland-Altman plots were used to detect the agreements between the two measurements. RESULTS: The relative reliability of PU, CKCUES, SMBT, and non-dominant arm USSP tests was excellent (ICC = 0.83, 0.80, 0.91, and 0.83, respectively). SEM was within a range of 1.69 to 1.72 for stability tests and a range of 13.61 to 52.12 for power (based on a 95% confidence interval). The MDC was 4.68 for PU and 4.75 for CKCUES test. At least four repetitions are needed to be considered a real improvement on PU and CKCUES tests. This value was 144.04, in SMBT and 59.03, 37.62 cm (dominant and non-dominant arm, respectively) in USSP tests, which represents the minimum change that must occur to be considered an athlete's progression. CONCLUSION: This study revealed that both the upper limb stability and power tests have acceptable relative and absolute intra-rater reliability in female overhead athletes. These can be considered as reliable tools in research and clinical settings.


Subject(s)
Muscle Strength , Upper Extremity , Humans , Female , Young Adult , Adult , Reproducibility of Results , Athletes , Physical Functional Performance
9.
Micromachines (Basel) ; 14(7)2023 Jun 30.
Article in English | MEDLINE | ID: mdl-37512657

ABSTRACT

Pulmonary drug transport has numerous benefits. Large surface areas for absorption and limited drug degradation of the gastrointestinal system are provided through the respiratory tract. The administration is painless and easy for the patient. Due to their better stability when compared to liquid formulations, powders have gained popularity among pulmonary formulations. In the pharmaceutical sector, quality assurance and product stability have drawn a lot of attention. Due to this, it was decided to perform a long-term stability study on a previously developed, nanosized dry powder inhaler (DPI) formulation that contained meloxicam. Wet milling was implemented to reduce the particle size, and nano spray-drying was used to produce the extra-fine inhalable particles. The particle diameter was determined using dynamic light scattering and laser diffraction. Scanning electron microscopy was utilized to describe the morphology. X-ray powder diffraction and differential scanning calorimetry were applied to determine the crystallinity. In an artificial lung medium, the in vitro dissolution was studied. The Andersen Cascade Impactor was used to investigate the in vitro aerodynamic characteristics. The stability test results demonstrated that the DPI formulation maintained its essential qualities after 6 and 12 months of storage. Consequently, the product might be promising for further studies and development.

10.
J Exerc Sci Fit ; 21(2): 210-217, 2023 Apr.
Article in English | MEDLINE | ID: mdl-36923209

ABSTRACT

Background: Upper limb balance is one of the important physical fitness parameters for all populations, especially overhead athletes like swimmers. Upper extremity star excursion balance test (UESEBT) is a comprehensive dynamic balance assessment, this study aims to explore the reliability and validity of UESEBT among adolescent swimmers. Methods: This cross-sectional study recruited 70 adolescent swimmers. All participants were required to complete UESEBT, upper quarter Y-balance test (UQYBT), maximal isometric strength (MIS) tests in upper limb, closed kinetic chain upper extremity stability test (CKCUEST), trunk flexor endurance test (TFET) and lateral trunk endurance test (LTET). The intra- and inter-operator reliability and the correlation of UESEBT with other physical performances were conducted. Results: For reliability, the intra- and inter-operator reliability of all directions and composite score were high-to-excellent (ICC = 0.706-1.000) among all participants. For validity, the UESEBT has a moderate-to-strong correlation with UQYBT (r = 0.42-0.72, p < 0.001), and a weak-to moderate one with CKCUEST (r = 0.25-0.42, p < 0.05). Furthermore, the UESEBT performance showed weak-to-moderate correlations with MIS (r = 0.24-0.44, p < 0.05). UESEBT was correlated to LTET (r = 0.24-0.33, p < 0.05) whereas no relationship was found with TFET. Conclusions: UESEBT was a reliable and valid tool to screen upper extremity dynamic balance among adolescent swimmers. UESEBT provides more detailed information in eight directions to assess the upper limb sport performance. Further study should explore the prediction ability of UESEBT for injury.

11.
ACS Appl Mater Interfaces ; 15(6): 8305-8318, 2023 Feb 15.
Article in English | MEDLINE | ID: mdl-36735879

ABSTRACT

Novel phase Q-carbon thin films exhibit some intriguing features and have been explored for various potential applications. Herein, we report the growth of different Q-carbon structures (i.e., filaments, clusters, and microdots) by varying the laser energy density from 0.5 to 1.0 J/cm2 during pulsed laser annealing of amorphous diamond-like carbon films with different sp3-sp2 carbon compositions. These unique nano- and microstructures of Q-carbon demonstrate exceptionally stable electrochemical performance by cyclic voltammetry, galvanostatic charging-discharging, and electrochemical impedance spectroscopy for energy applications. The temperature-dependent magnetic studies (magnetization vs magnetic field and temperature) reveal the ferromagnetic nature of the Q-carbon microdots. The saturation magnetization and coercive field values decrease from 132 to 14 emu/cc and 155 to 92 Oe by increasing the temperature from 2 to 300 K, respectively. The electrochemical performances of Q-carbon filament, cluster, and microdot thin-film supercapacitors were investigated by two-electrode configurations, and the highest areal specific capacitance of ∼156 mF/cm2 was observed at a current density of 0.15 mA/cm2 in the Q-carbon microdot thin film. The Q-carbon microdot electrodes demonstrate an exceptional capacitance retention performance of ∼97.2% and Coulombic efficiency of ∼96.5% after 3000 cycles due to their expectational reversibility in the charging-discharging process. The kinetic feature of the ion diffusion associated with the charge storage property is also investigated, and small changes in equivalent series resistance of ∼9.5% and contact resistance of ∼9.1% confirm outstanding stability with active charge kinetics during the stability test. A high areal power density of ∼5.84 W/cm2 was obtained at an areal energy density of ∼0.058 W h/cm2 for the Q-carbon microdot structure. The theoretical quantum capacitance was obtained at ∼400 mF/cm2 by density functional theory calculation, which gives an idea about the overall capacitance value. The obtained areal specific capacitance, power density, and impressive long-term cyclic stability of Q-carbon thin-film microdot electrodes endorse substantial promise in high-performance supercapacitor applications.

12.
Braz. J. Pharm. Sci. (Online) ; 59: e22505, 2023. tab, graf
Article in English | LILACS | ID: biblio-1439507

ABSTRACT

Abstract Natural products are considered an important source of the therapeutic arsenal currently available. Among these alternatives are the seeds of Ambrosia peruviana (altamisa), whose extract has shown an anti-inflammatory effect. The main objective of this work was to perform a preformulation study of Ambrosia peruviana seeds ethanolic extract, where the main factors that affect the physical, chemical, and pharmacological stability of the extract were evaluated, as well as a compatibility study by differential scanning calorimetry (DSC) analysis against different excipients. A dry extract was obtained by rotary evaporation of the seeds macerated with 96% ethanol. The anti-inflammatory activity was determined by measuring its effect on NO production in RAW 264.7 macrophages, stimulated with LPS. The results showed that the dry extract maintained its stability over time when stored at a temperature of 4 and 25ºC, demonstrating its biological activity, the content of phenolic compounds, and its physicochemical parameters remain practically invariable. However, when exposed to high temperatures (60 ºC) it was affected. The thermal analysis revelated that the behavior of most of the selected excipients and the dry extract was maintained, which indicates that it did not present incompatibilities, therefore they can be candidates for formulating a microemulsion.


Subject(s)
Seeds/metabolism , Asteraceae/classification , Ambrosia/adverse effects , Biological Products , Calorimetry, Differential Scanning/methods , Excipients/administration & dosage
13.
Brain Spine ; 2: 101668, 2022.
Article in English | MEDLINE | ID: mdl-36506288

ABSTRACT

Introduction: Motion preserving atlas ring osteosynthesis (C1-RO) for unstable Jefferson burst fractures (JBF) with insufficiency of the transverse atlantal ligament (TAL) is under debate. There is controversy about when to apply C1-RO and when further stabilization is needed. Research question: Is intraoperative stability testing after C1-RO with restoration of secondary stabilizers feasible, and what are mid-to long-term results of posterior C1-RO vs. C1-C2 ORIF in unstable Jefferson burst fractures with Dickman type I or II transverse atlantal ligament lesions based on intraoperative decision using this stability testing? Material and methods: Five consecutive patients with unstable JBF were treated with posterior C1-RO or C1-C2 ORIF based on the findings after intraoperative reduction and posterior C1-RO and stability testing. This newly developed intraoperative stability test based on the findings of biomechanical studies is a fluoroscopically controlled manual C1-C2 test with a force of approximately 50 â€‹N posterior-anterior stress and a tilting maneuver after C1-RO with repositioning. Clinical and radiological results of the cases with C1-RO were analyzed 3.5-21 months postoperatively. Results: Posterior C1-RO was performed in four patients. One case required C1-C2 fixation due to significant instability. In cases of C1-RO, stable bony fusions of the atlas ring were observed within a year. In flexion-extension views, the anterior atlanto-dental interval (AADI) did not increase until the latest follow-up. No complications were observed. Discussion and conclusion: The described intraoperative stability test after posterior C1-RO in unstable JBF enables the determination if C1-RO is sufficient or C1-C2 ORIF is necessary for treatment.

14.
BMC Oral Health ; 22(1): 286, 2022 07 14.
Article in English | MEDLINE | ID: mdl-35836169

ABSTRACT

BACKGROUND: Several devices have been developed to measure implant-bone stability as an indicator of successful implant treatment; these include Osstell®, which measures the implant stability quotient (ISQ), and the more recent AnyCheck®, which relies on percussion for the implant stability test (IST). These devices make it possible to measure implant stability. However, no studies have compared the performance of AnyCheck® and Osstell® (i.e., IST and ISQ values) in clinical practice. Therefore, this study aimed to determine the correlation between primary and secondary implant stability using the Osstell® and AnyCheck® devices. METHODS: Ten patients (7 women; age [mean ± standard deviation]: 49.1 ± 13.3 years) with partially edentulous jaws who received a total of 15 implants were included. IST (AnyCheck®) and ISQ (Osstell®) values were measured immediately after implantation and at 1, 2, 3, 4, and 6 weeks post-implantation. Each measurement was performed three times, and the average value was used as the result. The correlation between measurements obtained using the two devices was determined using Spearman's rank correlation coefficient. RESULTS: The IST values ranged from 79.1 ± 2.87 to 82.4 ± 2.65. The ISQ values ranged from 76.0 ± 2.8 to 80.2 ± 2.35. Spearman's rank correlation coefficient was r = 0.64 immediately after implantation, r = 0.29 at 1 week, r = 0.68 at 2 weeks, r = 0.53 at 3 weeks, r = 0.68 at 4 weeks, and r = 0.56 at 6 weeks. A positive correlation was found in all cases, except at week 1 when the correlation was weak; the IST and ISQ values decreased the most during the first postoperative week and increased during the second week. The IST values were also slightly higher at all measurement points. CONCLUSION: The ability to assess implant stability without removing the abutment during healing is essential for determining the timing of loading without the risk of bone resorption. The results of this study suggest that AnyCheck® is useful for determining primary and secondary implant stability.


Subject(s)
Dental Implants , Dental Prosthesis Retention , Adult , Bone and Bones , Dental Implantation, Endosseous/methods , Female , Humans , Middle Aged , Osseointegration , Percussion , Vibration
15.
Eur J Med Chem ; 235: 114295, 2022 May 05.
Article in English | MEDLINE | ID: mdl-35344901

ABSTRACT

Niclosamide, a widely-used anthelmintic drug, inhibits SARS-CoV-2 virus entry through TMEM16F inhibition and replication through autophagy induction, but the relatively high cytotoxicity and poor oral bioavailability limited its application. We synthesized 22 niclosamide analogues of which compound 5 was found to exhibit the best anti-SARS-CoV-2 efficacy (IC50 = 0.057 µ M) and compounds 6, 10, and 11 (IC50 = 0.39, 0.38, and 0.49 µ M, respectively) showed comparable efficacy to niclosamide. On the other hand, compounds 5, 6, 11 contained higher stability in human plasma and liver S9 enzymes assay than niclosamide, which could improve bioavailability and half-life when administered orally. Fluorescence microscopy revealed that compound 5 exhibited better activity in the reduction of phosphatidylserine externalization compared to niclosamide, which was related to TMEM16F inhibition. The AI-predicted protein structure of human TMEM16F protein was applied for molecular docking, revealing that 4'-NO2 of 5 formed hydrogen bonding with Arg809, which was blocked by 2'-Cl in the case of niclosamide.


Subject(s)
COVID-19 Drug Treatment , SARS-CoV-2 , Antiviral Agents/pharmacology , Antiviral Agents/therapeutic use , Humans , Molecular Docking Simulation , Niclosamide/pharmacology
16.
Nanomaterials (Basel) ; 12(3)2022 Jan 23.
Article in English | MEDLINE | ID: mdl-35159704

ABSTRACT

The development of active and stable photocatalysts for the degradation of volatile organic compounds under visible light is important for efficient light utilization and environmental protection. Titanium dioxide doped with nitrogen is known to have a high activity but it exhibits a relatively low stability due to a gradual degradation of nitrogen species under highly powerful radiation. In this paper, we show that the combination of N-doped TiO2 with bismuth tungstate prevents its degradation during the photocatalytic process and results in a very stable composite photocatalyst. The synthesis of Bi2WO6-TiO2-N composites is preformed through the hydrothermal treatment of an aqueous medium containing nanocrystalline N-doped TiO2, as well as bismuth (III) nitrate and sodium tungstate followed by drying in air. The effect of the molar ratio between the components on their characteristics and photocatalytic activity is discussed. In addition to an enhanced stability, the composite photocatalysts with a low content of Bi2WO6 also exhibit an enhanced activity that is substantially higher than the activity of individual TiO2-N and Bi2WO6 materials. Thus, the Bi2WO6-TiO2-N composite has the potential as an active and stable photocatalyst for efficient purification of air.

17.
Polymers (Basel) ; 14(1)2022 Jan 03.
Article in English | MEDLINE | ID: mdl-35012200

ABSTRACT

Carboxymethyl chitosan (CMCH) from native chitosan of high molecular weight (H, 310-375 kDa) was synthesized for improving water solubility. The water solubility of high-molecular-weight carboxymethyl chitosan (H-CMCH) was higher than that of native chitosan by 89%. The application of H-CMCH as enhancing the moisturizer in mangosteen extract deodorant cream was evaluated. Different concentrations of H-CMCH (0.5-2.5%) were investigated in physicochemical characteristics of creams, including appearance, phase separation, pH, and viscosity, by an accelerated stability test. The different degrees of skin moisturizing (DM) on pig skin after applying H-CMCH solution, compared with untreated skin, water, and propylene glycol for 15 and 30 min using a Corneometer®, were investigated. The results showed that the 0.5% H-CMCH provided the best DM after applying the solution on pig skin for 30 min. Trans-2-nonenal, as an unsatisfied odor component, was also evaluated against components of the mangosteen extract deodorant cream, which were compared to the standard, epigallocatechin gallate (EGCG). In addition, DPPH and ABTS radical scavenging activity, ferric reducing antioxidant power (FRAP), and antibacterial activities were examined for the mangosteen extract deodorant cream using 0.5% H-CMCH. Results indicated that the mangosteen extract synergized with H-CMCH, which had a good potential as an effective skin moisturizing agent enhancer, deodorizing activity on trans-2-nonenal odor, antioxidant properties, and antibacterial properties.

18.
J Sport Rehabil ; 31(4): 385-390, 2022 05 01.
Article in English | MEDLINE | ID: mdl-34969011

ABSTRACT

CONTEXT: Core stability is important for preventing injury and improving performance. Although various tests for evaluating core stability have been reported to date, information on their relationship and the effect of gender differences is limited. This study aimed to (1) identify correlations among the 3 core stability tests and to examine the validity of each test and (2) identify gender differences in the test relationship and determine whether gender influenced test selection. DESIGN: Cross-sectional study. METHODS: Fifty-one healthy volunteers (27 men and 24 women) participated in the study. The participants underwent the following 3 tests: Sahrmann Core Stability Test (SCST), the lumbar spine motor control tests battery (MCBT), and Y Balance Test (YBT). Each parameter was analyzed according to all parameters and gender using the Spearman rank correlation coefficient. RESULTS: Overall, there was a strong positive correlation between SCST and MCBT and moderate positive correlations between SCST and YBT and between MCBT and YBT. Conversely, gender-specific analyses revealed no significant correlations between YBT and SCST and between YBT and MCBT in women, although significantly strong correlations were found among all tests in men. CONCLUSION: Although these 3 tests evaluated interrelated functions and may be valid as core stability tests, the results should be carefully interpreted when performing YBT in women.


Subject(s)
Core Stability , Health Status , Cross-Sectional Studies , Female , Humans , Male , Postural Balance , Sex Factors , Young Adult
19.
Article in English | WPRIM (Western Pacific) | ID: wpr-977481

ABSTRACT

Aims@#The microbial pigment can be the best promising alternative to replace synthetic colorant. However, due to the high cost of synthetic medium for microbial pigment production, there is a need to develop a new low-cost medium of bacterial pigment production. This study aims to investigate the potential of banana and papaya peels as alternative lowcost substrates for a carotenoid-producing bacterium, B12 strain (bacteria strain isolated from Holothuria (Lessonothuria) pardalis).@*Methodology and results@#B12 strain identified as an aerobic bacterium with non-motile, diplobacilli shaped and Grampositive bacteria. The fermentation was optimized with different parameters included the effect of temperature, time, concentrations, pHs, carbon and nitrogen sources to find the optimum relative pigment concentration produced by B12. The results showed that the B12 strain produced the highest relative pigment concentration measured at 450 nm when the strain was cultivated at 37 °C and pH 7 in the culture medium incorporated with the combination of dried papaya peels and banana peels (100% v/v with ratio 1:1) at 72 h of incubation. Lactose, peptone and yeast were observed as the best carbon and nitrogen sources to increase the pigment concentration of B12 strain. Stability of the pigment was studied at different physiochemical stress, and it showed the pigment obtained from dried papaya and banana substrates can tolerate and stable under stress condition.@*Conclusion, significance and impact of study@#This can be concluded that the combination of dried papaya and banana peels worked well as substrate and can be utilized as a fermentation medium to replace the synthetic medium which is more expensive and uneconomical for industry application. Besides, it also helps in managing waste and solving the pollution problem due to the increasing of biochemical oxygen demand (BOD) and chemical oxygen demand (COD).


Subject(s)
Gram-Positive Bacterial Infections , Holothuria , Carica , Musa
20.
Acta Pharmaceutica Sinica ; (12): 2503-2511, 2022.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-937042

ABSTRACT

In order to meet the clinical needs of long-acting sustained-release thienorphine, injectable thienorphine loaded microspheres were developed, and the accelerated stability study was carried out to explore the suitable storage and transportation conditions of the microspheres. Using poly(lactic-co-glycolic acid) (PLGA) as carrier material, 3 batches of microspheres were prepared in pilot scale with emulsion solvent evaporation method. By investigating the in vitro release of thienorphine loaded microspheres at 37, 45, 52, and 60 ℃, and applying the Arrhenius equation, the linear relationship between the release rate constant (lgk) and the temperature (1/T) was established to obtain the equation: lgk = -8.073/T + 24.35 (R2 = 0.985 3), which showed that the release of microspheres at high temperature can be used to predict the release in vitro at 37 ℃, and 52.0 ± 0.5 ℃ was selected as the accelerated release condition in vitro. The quality research methods were established to investigate the changes of critical quality attributes such as microsphere morphology, drug loading, particle size and distribution, polymer molecular weight, and the related substances under accelerated conditions. The difference factor f1 and similarity factor f2 were used to assess the similarity of release behavior under accelerated conditions. The results showed that under the accelerated experimental conditions of 25 ± 2 ℃ and relative humidity (RH) 60% ± 5%, the critical quality attributes of injectable thienorphine loaded microspheres had no significant change in 6 months, suggesting that the long-term storage condition could be 5 ± 3 ℃.

SELECTION OF CITATIONS
SEARCH DETAIL
...