Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 23
Filter
1.
Medicina (Kaunas) ; 59(1)2023 Jan 13.
Article in English | MEDLINE | ID: mdl-36676786

ABSTRACT

Introduction: a primary goal in revision total knee arthroplasty is to recreate and restore near-normal knee biomechanics by reapproximating the native anatomy. Tibial bone loss poses a challenge for surgeons. Bone cement, bone allograft, screws-in-cement, metaphyseal sleeves or cones, and metallic augments are some options for addressing bony deficiency, with endoprosthetic proximal tibia replacement a consideration for the most severe cases. Case Description: we present a case for the novel use of threaded Steinmann pins augmented with cement to reconstruct a massive tibial metaphyseal cortical defect during revision knee arthroplasty. A 76-year-old male presented with an infected primary total knee arthroplasty using MSIS (Musculoskeletal Infection Society) criteria and underwent a standard two-stage revision total knee arthroplasty once the knee was confirmed sterile. Intraoperatively, significant posteromedial and metaphyseal tibial bone loss was identified. In order to avoid proximal tibial replacement and the extensor mechanism complications seen with these, coupled with obligate gastrocnemius flap, a metaphyseal cone was utilized in the proximal tibia with four vertical threaded Steinmann pins spaced approximately 1 cm apart at its periphery, subsequently cut flush with the level of the cone after cementation to recreate the tibial cortex. The patient's function and range of motion continue to improve with no evidence of structural complication at 2.5 years of follow-up. Discussion: the implementation of threaded Steinmann pins was utilized in this case to stabilize a cemented metaphyseal cone in the revision of an infected total knee with significant tibial bone loss. The threaded property may help prevent migration of these pins in comparison to smooth pins. Creation of a stable platform in a revision total knee arthroplasty poses a substantial challenge in the context of significant bone loss, and our case depicts a good short-term outcome and another option for surgeons to consider before moving toward endoprostheses.


Subject(s)
Arthroplasty, Replacement, Knee , Knee Prosthesis , Male , Humans , Aged , Tibia/surgery , Bone Cements/therapeutic use , Prosthesis Design , Reoperation , Knee Joint/surgery , Bone Nails
2.
Injury ; 52 Suppl 3: S33-S37, 2021 Jul.
Article in English | MEDLINE | ID: mdl-34088470

ABSTRACT

INTRODUCTION: Forearm shaft fracture is common in young adult patients and associated with soft tissue and organ injuries. In open fractures in polytrauma patients, damage control orthopaedics (DCO) is well indicated. The aim of this study is to describe intramedullary Steinmann pin fixation of the ulna as a DCO procedure for the forearm and present a case series. DESCRIPTION OF THE TECHNIQUE: A 3.0 mm Steinmann pin is inserted retrograde in the ulna proximal fragment through the fracture site using the open wound as the approach. With direct visualization of the reduction, the pin is advanced into the distal fragment. The reduction of the longitudinal axis and shortening is thus achieved. PATIENTS AND METHODS: This method was used for all open fractures of forearm both-bone fractures in polytrauma patients undergoing DCO from 2014 to 2019. The alignment and length of the ulna were evaluated radiographically after pin fixation and before and after definitive fixation. Differences in the need for secondary procedures and infection rate between DCO and definitive fixation were also evaluated. RESULTS: There were 30 males (85.7%) with an average age of 32.9 ± 12.0 years and a mean ISS (Injury Severity Score) of 29.4 (range, 18.0-41.0). The most common associated injuries were thoracic trauma (62.8%) and head trauma (45.7%). In the radius and ulna, 51.4% and 60.0% of fractures, respectively, were multifragmentary (types B and C). Gustilo type IIIA represented 77.1% of the injuries. Pin fixation achieved good alignment and length in all cases. The mean time between DCO and definitive fixation was 12.0 days, and no secondary procedure was needed, nor any case developed either superficial or deep infection. The conversion from DCO to definitive fixation was considered easy in all cases. CONCLUSION: Intramedullary Steinmann pin fixation of the ulna is a viable option for DCO for forearm both-bone fractures in open fractures in polytrauma patients.


Subject(s)
Forearm Injuries , Fracture Fixation, Intramedullary , Fractures, Open , Orthopedics , Radius Fractures , Ulna Fractures , Adult , Forearm , Forearm Injuries/diagnostic imaging , Forearm Injuries/surgery , Fractures, Open/diagnostic imaging , Fractures, Open/surgery , Humans , Male , Radius Fractures/diagnostic imaging , Radius Fractures/surgery , Retrospective Studies , Treatment Outcome , Ulna/diagnostic imaging , Ulna/surgery , Ulna Fractures/diagnostic imaging , Ulna Fractures/surgery , Young Adult
3.
J Orthop Surg Res ; 16(1): 409, 2021 Jun 26.
Article in English | MEDLINE | ID: mdl-34174925

ABSTRACT

BACKGROUND: Percutaneous pinning fixation (PCP) has been used for the treatment of distal radius fractures for decades, especially in the elderly with fragile soft tissue. However, achieving and maintaining a sound anatomic reduction before PCP is difficult if we use the manipulative reduction method alone. Our study innovatively applied the Steinmann pin retractor for closed reduction combined with PCP, to provide a new protocol for the treatment of distal radius fractures. METHODS: From March 2017 to July 2018, 49 patients out of 57 that met the inclusion criteria but not the exclusion criteria were included in our retrospective cohort study. Sixteen patients were treated with Steinmann pin retractor-assisted closed reduction combined with PCP (S-PCP), and 19 patients were treated with the manipulative reduction combined with PCP (M-PCP), and 14 patients were treated with the manipulative reduction combined with cast splint (M-C). All these patients received a positive postoperative radiological and clinical evaluation. RESULTS: All the patients were followed up for a minimum of 2 years. The radiological parameters in each group improved significantly postoperative (posttreatment). In the S-PCP group, the values of radial height (postoperative, 13.33±1.74 mm; the first follow-up, 13.27±1.81mm; last follow-up, 13.16±1.76mm) and ulnar variance (postoperative, -0.10±1.29mm; the first follow-up, -0.05±1.27mm; last follow-up, -0.12±1.09mm) significantly improved as compared to the M-PCP and M-C groups. While the patients in the M-C group experienced significant re-displacement at the first and last follow-ups, in the S-PCP group, the range of wrist motion including extension (89.94±5.21%), radial deviation (90.69±6.01%), and supination (90.25±5.87%); ulnar deviation (89.81±5.82%) and QuickDASH score (2.70±3.64); and grip strength (92.50±5.59%), pronation (90.50±6.04%), and modified Mayo wrist score (90.94±4.17, the excellent rate reached up to 75%) also improved as compared to the M-PCP group, M-C group, or both groups at the last follow-up. CONCLUSION: S-PCP improves fracture reduction and wrist function and can serve as an effective method for A2(AO/OTA) and A3 type of distal radius fractures in the elderly with limited dorsal comminution, including intra-articular fractures with displacement less than 2mm.


Subject(s)
Bone Nails , Closed Fracture Reduction/instrumentation , Fracture Fixation, Intramedullary/instrumentation , Intra-Articular Fractures/surgery , Radius Fractures/surgery , Aged , Aged, 80 and over , Closed Fracture Reduction/methods , Female , Fracture Fixation, Intramedullary/methods , Fracture Healing , Humans , Intra-Articular Fractures/diagnostic imaging , Intra-Articular Fractures/physiopathology , Male , Middle Aged , Radiography , Radius/diagnostic imaging , Radius/physiopathology , Radius Fractures/diagnostic imaging , Radius Fractures/physiopathology , Retrospective Studies , Splints , Treatment Outcome
4.
World J Clin Cases ; 9(6): 1379-1385, 2021 Feb 26.
Article in English | MEDLINE | ID: mdl-33644205

ABSTRACT

BACKGROUND: Pigmented villonodular synovitis (PVNS) is an uncommon disease that usually occurs in large joints, and involvement of the subtalar joint is rare. The lack of comprehensive knowledge of subtalar joint PVNS could lead to misdiagnosis. CASE SUMMARY: We present a 64-year-old woman who, at her first visit, complained of discomfort in the right ankle when she walked. Based on the physical signs and X-ray report, the physician failed to make the suspected diagnosis of PVNS. Eighteen months later, the patient returned with a complaint of a mass in her right lateral malleolus with intermittent blunt pain. The X-ray presented an osteophyte formation and soft tissue calcification at the margin of the subtalar joint. The laboratory tests were normal, whereas magnetic resonance imaging (MRI) showed a low-intensity area on both T1- and T2-weighted images. A suspected diagnosis of PVNS was made and later confirmed by postoperative pathology. Subsequently, the patient received radiotherapy with 32 Gy in 16 fractions. At 6 mo postoperatively, the patient only complained of discomfort after walking three blocks. The American Orthopedic Foot and Ankle Society Ankle-Hindfoot score was 97. CONCLUSION: MRI is necessary for the diagnosis of PVNS. Early soft tissue calcification and painless joint swelling should be of concern.

5.
Knee Surg Sports Traumatol Arthrosc ; 29(1): 223-229, 2021 Jan.
Article in English | MEDLINE | ID: mdl-32232537

ABSTRACT

PURPOSE: To evaluate the incidence of intraoperative anchor pullout during arthroscopic rotator cuff repair, to compare the outcomes of different methods of managing anchor pullout, and to introduce a new technique for anchor pullout. METHODS: 1076 patients who underwent arthroscopic rotator cuff repair using a single-row repair technique were included. In 483 patients, rotator cuff repair was performed using a screw-in type anchor, and in 593 patients, soft anchors were used. When intraoperative anchor pullout occurred, it was managed by buddy screwing, anchor insertion in a different location, cement augmentation, or by bar anchoring using a threaded Steinmann pin. Plain radiography and sonography were used to check anchor locations and healing. RESULTS: Fifty-two patients experienced anchor pullout intra- or postoperatively (48 and four patients, respectively). Anchor pullouts were more frequently observed for larger tears, women, older patients, and in patients with preoperative stiffness (limitations of both active and passive movements of the affected shoulder joint). For screw-in type anchors, pullout during surgery occurred in 16 patients (3.3%, 16/483), and all were managed using the buddy screwing technique. For soft anchor cases, pullout occurred in 32 patients (5.4%, 32/593) and was managed by anchor insertion in a different location (17 patients), cement augmentation (two patients), or bar anchoring using a threaded Steinmann pin (13 patients). Three patients managed by buddy screwing and two patients managed by anchor insertion in a different location had anchor failure after repair. Tendon healing at 6 months was observed in 12/16 patients treated by buddy screwing, 11/17 treated by anchor insertion in a different location, 2/2 treated by cement augmentation, and 12/13 treated by bar anchoring with a threaded Steinmann pin. CONCLUSION: Intraoperative anchor pullout during arthroscopic rotator cuff repair is an uncommon but cumbersome complication. There are some techniques already introduced to deal with this complication. In comparison, not one technique is overwhelmingly superior to others; however, our new technique which is bar anchoring with a threaded Steinmann pin could be another solution, since it could utilize primary anchor sites and results appear to be acceptable. Level of evidence III.


Subject(s)
Arthroscopy/methods , Rotator Cuff Injuries/surgery , Suture Anchors , Aged , Arthroscopy/adverse effects , Arthroscopy/instrumentation , Bone Cements , Female , Humans , Intraoperative Complications/surgery , Male , Middle Aged , Radiography , Rotator Cuff/diagnostic imaging , Rotator Cuff/surgery , Rotator Cuff Injuries/diagnostic imaging , Suture Techniques , Ultrasonography
6.
Clin Orthop Surg ; 12(3): 396-403, 2020 Sep.
Article in English | MEDLINE | ID: mdl-32904052

ABSTRACT

BACKGROUD: Controversy exists about the optimal treatment of midshaft clavicle fractures in the presence of significant displacement, comminution, or shortening of the fracture in adolescents. The purpose of this study was to compare the clinical and radiological outcomes of 4 different treatments for midshaft clavicle fractures in adolescents: conservative treatment with a figure-of-8 (FO8) brace, open reduction and internal fixation with a plate (OPL), minimally invasive plate osteosynthesis (MIPO), and intramedullary nail fixation with a threaded Steinmann pin (TSP). METHODS: A total of 94 teenagers with midshaft clavicle fractures were divided into the FO8, OPL, MIPO, and TSP groups (n = 24, 33, 16, and 21, respectively). We analyzed clinical and radiological outcomes and complications in each group and compared the results among the groups. RESULTS: All groups showed satisfactory clinical and radiological outcomes, but each group showed different results for the assessment items. The Constant-Murley scores were higher in the operated groups than in the FO8 group. Recovery of joint motion was faster in the operated groups. The TSP group had the highest cosmetic satisfaction with respect to the satisfaction score and measured scar length. Fracture union was achieved in all patients. At the final follow-up, the bone length was closer to normal in the OPL and TSP groups than in the FO8 and MIPO groups, and angulation was less in the OPL and TSP groups than in the MIPO and FO8 groups. The TSP and MIPO groups obtained faster bone healing than the OPL and FO8 groups. In the operated groups, 9 patients had metal-induced irritating symptoms; 1, supraclavicular nerve injury symptoms; and 4, refractures after plate removal. CONCLUSIONS: The nonoperatively treated group had no iatrogenic complications. The operated groups complained of various disadvantages induced by surgery; however, these groups achieved faster functional recovery and slightly better radiological and functional results than the nonoperative group.


Subject(s)
Braces , Clavicle/injuries , Fracture Fixation, Internal , Fractures, Bone/therapy , Open Fracture Reduction , Adolescent , Bone Plates , Child , Clavicle/diagnostic imaging , Disability Evaluation , Female , Fractures, Bone/diagnostic imaging , Humans , Male , Retrospective Studies
7.
J Orthop Surg Res ; 14(1): 363, 2019 Nov 14.
Article in English | MEDLINE | ID: mdl-31727172

ABSTRACT

BACKGROUND: Sinus tarsi approach and mini-calc plate have been used for intra-articular calcaneal fractures. However, the sinus tarsi approach has limited exposure to the lateral wall, which makes it challenging to obtain an excellent anatomic reduction of the calcaneal body. What is more! To restore the width of the calcaneal body entirely and prevent the heel varus simultaneously with mini-calc plate was tough as well. Aimed to solve the aforementioned problems, our study focused on using the Steinmann pin retractor for reduction and the circle plate for fixation via the sinus tarsi approach. METHODS: From March 2017 to January 2019, 15 patients with closed calcaneal fractures were treated with the method of Steinmann pin retractor-assisted reduction and circle plate fixation via the sinus tarsi approach. All these patients received a positive postoperative clinical and radiological evaluation. RESULTS: A postoperative follow-up was done for each of the 15 patients, and the following scores and parameters were observed: value of visual analogue scale (VAS) was 1.44 ± 0.63, and The American Orthopaedic Foot and Ankle Score (AOFAS) Ankle-Hindfoot score was 84.31 ± 5.03 at the last follow-up. The Böhler angle (30.81 ± 3.56°), width (37.83 ± 4.87 mm), length (87.4 ± 3.33 mm), and height (86.23 ± 5.36 mm) of the calcaneus were improved significantly in comparison with preoperative values (- 0.94 ± 10.06°, 45.67 ± 5.68 mm, 82.72 ± 5.54 mm, 76.32 ± 7.98 mm), and these parameters were maintained excellently after 6-19 months' follow-up. CONCLUSION: Our present study suggested that Steinmann pin retractor-assisted reduction with circle plate fixation via the sinus tarsi approach may serve as a safe and effective method for Sanders type II and type III calcaneus fractures. The Böhler angle, height, length, and body of the calcaneus were excellently restored postoperatively and maintained at last follow-up and rare postoperative complications. TRIAL REGISTRATION: This study has been registered. The unique identifying number is research registry 5092.


Subject(s)
Calcaneus/injuries , Fracture Fixation, Internal/methods , Fractures, Closed/surgery , Adult , Aged , Aged, 80 and over , Calcaneus/diagnostic imaging , Fracture Fixation, Internal/instrumentation , Fractures, Closed/diagnostic imaging , Humans , Male , Middle Aged , Retrospective Studies
8.
World Neurosurg ; 108: 560-565, 2017 Dec.
Article in English | MEDLINE | ID: mdl-28927912

ABSTRACT

OBJECTIVE: The authors describe a modified technique for placement of the C1 lateral mass screw using a Steinmann pin as a guide. This technique minimizes dissection and provides atlantoaxial stabilization during arthrodesis. METHODS: In our technique, a nonthreaded 1.6-mm spade-tip Steinmann pin is placed into the lateral mass of C1 to serve as a guide over which a powered drill is used for screw insertion. Perioperative data were collected for consecutive patients who underwent a C1-2 arthrodesis that involved the modified technique between March 2010 and July 2016. Data included blood loss, operative times, and C2 nerve root injury. RESULTS: The data for 93 patients were reviewed. Most (91.4%) patients presented with a fracture from an acute trauma. A mean of 1.97 levels was fused in these patients, with a mean blood loss of 76 mL and a mean operative time of 144 minutes. The overall morbidity and mortality rate was 10.7%. The morbidity rate of 7.5% included 30-day postoperative complications of respiratory failure and dysphasia. There were no postoperative vertebral artery injuries, hardware failures, or instances of occipital neuralgia. CONCLUSIONS: The use of Steinmann pins to guide the placement of C1 lateral mass screws is safe and effective in C1-2 arthrodesis. Limiting dissection minimizes blood loss and injury, maintains efficient operative time, and assists in accurate placement of the screws. Furthermore, with less manipulation and retraction of the C2 nerve root, postoperative occipital neuralgia and the need for C2 root transection are avoided.


Subject(s)
Atlanto-Axial Joint/surgery , Bone Screws , Cervical Atlas/surgery , Spinal Fusion , Adolescent , Adult , Aged , Aged, 80 and over , Atlanto-Axial Joint/diagnostic imaging , Blood Loss, Surgical , Cervical Atlas/diagnostic imaging , Female , Follow-Up Studies , Humans , Joint Instability/diagnostic imaging , Joint Instability/mortality , Joint Instability/surgery , Male , Middle Aged , Operative Time , Postoperative Complications/epidemiology , Retrospective Studies , Spinal Fractures/diagnostic imaging , Spinal Fractures/mortality , Spinal Fractures/surgery , Spinal Nerve Roots/diagnostic imaging , Spinal Nerve Roots/injuries , Treatment Outcome , Young Adult
9.
Foot (Edinb) ; 32: 35-38, 2017 Aug.
Article in English | MEDLINE | ID: mdl-28672133

ABSTRACT

INTRODUCTION: Because of poor skin conditions and comorbidity, open reduction and internal fixation in ankle fractures is frequently contra-indicated in the elderly. This study reports the results of two temporary fixation types in fragility fractures in the older patient: transarticular Steinmann pin fixation and external fixation. METHODS: Patients aged over 60 treated with a Steinmann pin or external fixation were retrospectively included. Patient, fracture and treatment characteristics were collected. RESULTS: Fifteen patients were included. Nine were managed using a Steinmann pin and six by external fixation. All reached fracture consolidation. Patients treated with a Steinmann pin underwent a median of 2 operations and the pin was left in situ for 80 days. Three patients suffered from superficial wound infection. X-ray showed malreduction in 67% and only two patients returned to pre-injury mobility. A median of 2 operations with 32 fixation days was reported in the external fixation group. This group showed one deep infection. In 50% there was malreduction, one patient experienced disability in ambulation at the end of treatment. CONCLUSION: Both techniques show few complications, but have, as expected, poor results in fracture reduction and functional outcome. External fixation and subsequent internal fixation could result in better functional outcome.


Subject(s)
Ankle Injuries/surgery , Bone Nails , External Fixators , Fracture Fixation, Internal/instrumentation , Age Factors , Aged , Aged, 80 and over , Ankle Injuries/diagnostic imaging , Chi-Square Distribution , Cohort Studies , Female , Fracture Fixation, Internal/methods , Fracture Healing/physiology , Frail Elderly , Geriatric Assessment , Humans , Male , Middle Aged , Recovery of Function , Retrospective Studies , Risk Assessment , Statistics, Nonparametric
10.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-607185

ABSTRACT

Objective To analyze the indications and evaluate the efficacy of the needle to 'double reverse' traction reset,inside and outside double column locking plate internal fixation with MiPPO for tibial plateau fractures.Methods From August 2015 to March 2017,a total of 31 patients with tibial plateau fractures in our hospital were divided into treatment group and control group.The treatment group with 12 cases were treated with the needle to be 'double reverse' traction reset,inside and outside double column locking plate MiPPO fixation.The control group with 19 cases received open reduction and internal fixation with locking plate.Results In treatment group,the operation time was (51.3±6.5)minutes,the intraoperative bleeding was (60±8.7)mL.In the control group,the operation time was (68.5±6.6)minutes,the intraoperative bleeding was (230±7.8)mL.The operation time and blood loss of treatment group were less than those of control group,the differences were statistically significant(P<0.05).The postoperative X ray film of fracture showed that the bone plate and screw position were ideal compared with those before operation,no complication occurred.Conclusion The needle 'double inverse' traction and locking plate MiPPO fixation treatment have good clinical effect for patients of Schatzker Ⅴ,Ⅵ tibia platform fracture,with less complication.

11.
J Orthop Traumatol ; 17(3): 249-54, 2016 Sep.
Article in English | MEDLINE | ID: mdl-26883439

ABSTRACT

BACKGROUND: Aggressive bone neoplasms, such as giant cell tumors, often affect the proximal tibia warranting bony resection via curettage leaving behind massive defects that require extensive reconstruction. Reconstruction is usually accomplished with poly(methyl methacrylate) (PMMA) packing supplemented with an internal fixation construct. The purpose of this study is to compare Steinmann pin augmentation to locking plate constructs to determine which offers the stiffer reconstruction option. MATERIALS AND METHODS: Large defects were created below the lateral condyle of fresh frozen tibias. The defects extended for an average of 35 mm beneath the lateral plateau in the frontal plane, and from the anterior to posterior cortex in the sagittal plane. Distally the defect extended for an average of 35 mm to the metadiaphyseal junction. In the Pin group, the tibias were reconstructed with three 4-mm diameter Steinmann pins placed in the medullary canal and PMMA packing. In the Plate group, the tibias were reconstructed with a 6-hole 3.5-mm LCP Proximal locking plate fixed to the proximal-lateral tibia utilizing seven 3.5-mm screws and PMMA packing. The tibias were tested for stiffness on a MTS machine by applying up to 400 N to the tibial plateau in force control at 5 N/s. Fatigue properties were tested by applying a haversine loading waveform between 200 N and 1,200 N at 3 Hz simulating walking upstairs/downstairs. RESULTS: Locking plate constructs (801.8 ± 78 N/mm) had greater (p = 0.041) stiffness than tibial constructs fixed with Steinmann pins (646.5 ± 206.3 N/mm). CONCLUSIONS: Permanent deformation was similar between the Pin and Plate group; however, two tibia from the Pin group exhibited displacements >5 mm which we considered failure. LEVEL OF EVIDENCE: n/a.


Subject(s)
Bone Nails , Bone Plates , Fracture Fixation, Internal/methods , Fractures, Bone/surgery , Tibia/pathology , Tibia/surgery , Cadaver , Female , Humans , In Vitro Techniques , Male , Middle Aged , Polymethyl Methacrylate , Treatment Outcome
12.
J Arthroplasty ; 31(7): 1555-60, 2016 07.
Article in English | MEDLINE | ID: mdl-26872586

ABSTRACT

BACKGROUND: Surgical management of advanced periacetabular lesions is challenging because of extensive bone loss, particularly for Modified American Academy of Orthopaedic Surgeons Classification defects type IV (pelvic discontinuity with posterior column involvement). Multiple methods for rebuilding the acetabulum have been described; all involve passing Steinmann pins in a retrograde or an antegrade fashion from the anterior iliac wing or iliac crest around the acetabulum in an attempt to recreate the normal bony anatomy. However, these techniques fail to engage the ischium in its entirety. The ischial contribution to the posterior column is a critical element in a stable acetabular construct. METHODS: After curettage of the acetabular lesion, Steinmann pins are passed through the ischial tuberosity and posterior column into the sciatic buttress in a retrograde manner. The number of pins depends on the size of the defect and involvement of the posterior column. PATIENTS AND METHODS: Medical records of 11 patients with a Modified American Academy of Orthopaedic Surgeons Classification defect type IV treated with retrograde ischioacetabular Steinmann pin reconstruction at our institution between 2007 and 2012 were reviewed. European Quality of Life-5 dimensions and Lower Extremity Functional Scale questionnaires were used to assess patient functional outcomes. RESULTS: The 6 patients (4 females and 2 males; age range, 56-81 years) surviving 12 months postoperatively reported improved mobility and good quality-of-life scores. CONCLUSION: We described a new method for posterior acetabular column reconstruction that uses the ischial tuberosity and body as additional points of stabilization during the reconstruction of the posterior column.


Subject(s)
Acetabulum/surgery , Arthroplasty, Replacement, Hip/methods , Bone Cements , Bone Nails , Bone Neoplasms/surgery , Carcinoma/surgery , Adult , Aged , Aged, 80 and over , Female , Hip/surgery , Humans , Male , Middle Aged , Neoplasm Metastasis , Pelvis/surgery , Prosthesis Design , Quality of Life , Surveys and Questionnaires
13.
Article in Korean | WPRIM (Western Pacific) | ID: wpr-67729

ABSTRACT

PURPOSE: To report the radiographic and clinical results of 6.5 mm cancellous full threaded buttress screw or Steinmann pin fixation to maintain a reduction of calcaneal posterior facet depression fracture. MATERIALS AND METHODS: From June 2009 to June 2012, 50 consecutive cases with calcaneal joint depression fracture that underwent open reduction and screw or pin fixation were enrolled in this study. A 6.5 mm cancellous full threaded screw was inserted from the posteroinferior aspect of the calcaneal tuberosity to the posterior facet (group A) or Steinman pin was inserted from the posterosuperior aspect of the calcaneal tuberosity to the calcaneocuboidal joint (group B). Both preoperative and postoperative Bohler and Gissane angles were measured radiographically, and American Orthopaedic Foot and Ankle Society (AOFAS) ankle-hindfoot scale on the final follow-up were assessed. RESULTS: The mean age of patients was 44.1 years, and the mean follow-up period was 27.2 months. According to the Sanders classification, 28 cases were type II and 22 cases were type III. In Sanders type II, Bohler and Gissane angles improved significantly from 10.1degrees and 126.2degrees preoperatively to 27.2degrees and 117.1degrees, respectively, in the immediate postoperative radiograph, and at the final follow-up, 26.6degrees and 118.6degrees, respectively. In Sanders type III, Bohler and Gissane angles improved significantly from 5.0degrees and 129.8degrees to 29.9degrees and 119.3degrees, respectively, in the immediate postoperative radiograph, and 26.9degrees and 120.2degrees at the final follow-up. All cases achieved bony union, and the average period until complete union was 13.3 weeks. AOFAS ankle-hindfoot scale was 82.6 in Sanders type II and 77.3 in Sanders type III at the final follow-up. CONCLUSION: A 6.5 mm cancellous full threaded buttress screw or Steinman pin fixation is a noninvasive treatment method with a merit of being able to maintain the bearing capacity of the posterior facet comparable to plate fixation.


Subject(s)
Humans , Ankle , Calcaneus , Classification , Depression , Follow-Up Studies , Foot , Intra-Articular Fractures , Joints
14.
Article in Korean | WPRIM (Western Pacific) | ID: wpr-192978

ABSTRACT

PURPOSE: Nail insertion is the treatment of choice for subtrochanteric femoral fracture, but displacement of proximal bone fragment makes it difficult to find an ideal entry point. Therefore, in this study we aimed to determine the usefulness of treatment of subtrochanteric femoral fracture using Steinmann pin assisted reduction, internal fixation, and insertion of intramedullary nails. MATERIALS AND METHODS: We evaluated 33 patients who were followed-up more than a year with a displaced subtrochanteric femoral fracture treated with closed reduction and intramedullary nail fixation between January 2008 and March 2013. In addition, we studied postoperative bone union time, postoperative reduction status, change of the femur neck shaft angle, evaluation of hip joint function, return to daily life, and complications. RESULTS: All fractures with Steinmann pin assisted reduction were united but they included three cases of delayed union. In Fogagnolo classification, all cases were up to acceptable states and the varus change of femur neck shaft angle was 0.94degrees+/-3.1degrees; no significant difference in Harris hip score was observed between preoperative and last follow-up (p>0.05). CONCLUSION: There were satisfactory results in bone union and reduction state with Steinmann pin assisted reduction. Therefore, Steinmann pin assisted reduction is a useful surgical technique for subtrochanteric femoral fracture.


Subject(s)
Humans , Classification , Femoral Fractures , Femur Neck , Follow-Up Studies , Hip , Hip Joint
15.
J Foot Ankle Surg ; 52(6): 724-7, 2013.
Article in English | MEDLINE | ID: mdl-24021265

ABSTRACT

During the past 15 years, tibiotalocalcaneal nail arthrodesis has become an established procedure for the treatment of specific disorders of the hindfoot and ankle. However, controversy exists regarding the proper starting point for obtaining and maintaining the correct hindfoot position to allow successful fusion. One of the challenges with this procedure is aligning the tibial canal with the central talus and calcaneus for placement of the intramedullary nail. We performed a cadaver study to evaluate the radiographic and anatomic position of the tibial canal and the central talus as it relates to placement of a retrograde tibiotalocalcaneal nail. In our subjects, guide wires directed in an antegrade fashion down the tibial canal were more likely to enter lateral to the midline of the talus and miss the calcaneal body medially. These data have revealed a mismatch among the central axis of the tibia, talus, and calcaneus. Surgeons must pay careful attention to wire placement across these 3 bone segments during retrograde tibiotalocalcaneal nailing.


Subject(s)
Arthrodesis/methods , Calcaneus/surgery , Foot Diseases/surgery , Talus/surgery , Tibia/surgery , Ankle Joint/surgery , Bone Nails , Bone Wires , Cadaver , Fracture Fixation, Intramedullary , Humans
16.
J Clin Orthop Trauma ; 4(3): 139-42, 2013 Sep.
Article in English | MEDLINE | ID: mdl-26403554

ABSTRACT

A plethora of complications have been reported after insertion of a Steinmann pin amongst which the commonest ones are infection and pin loosening. We present a literature review on pathological fractures arising out of cortical defects left behind by pin insertion and report a unique case where a Steinmann pin insertion in proximal tibia has given rise to a fracture as late as 3 years after insertion.

17.
Indian J Orthop ; 45(2): 178-80, 2011 Mar.
Article in English | MEDLINE | ID: mdl-21430875

ABSTRACT

An anterior tibial artery pseudoaneurysm is a rare and unexpected complication of Steinmann pin insertion. We describe the case of an 18-year-old boy, who sustained such an injury to the anterior tibial artery during this procedure. Diagnosis was confirmed on a magnetic resonance (MR) angiogram. Aneurysmal sac excision with lateral repair of the vessel wall was performed. Postoperatively, a good flow was documented on a follow-up MR angiogram. This case highlights a major and unexpected complication of a so-called minor procedure. Too posterior a pin placement in the proximal tibia should be avoided to prevent such injuries.

18.
Article in Korean | WPRIM (Western Pacific) | ID: wpr-200956

ABSTRACT

PURPOSE: To evaluate the usefulness of internal fixation with modified Steinmann pins and tension band wiring technique in comminuted proximal humeral fracture with osteoporosis and the correlations among bone mineral density, age, Neer's score and period of union. MATERIALS AND METHODS: Twelve cases of comminuted proximal humeral fracture with osteoporosis were surgically treated with modified Steinmann pins and tension band technique, and followed up for an average 20.8 months (range, 6~39 months). Average age was 73.6 years old (range, 59~85 years old). Results were assessed using Neer's evaluation criteria. RESULTS: Excellent results were noted in eight cases and satisfactory results in four cases. Radiological union was obtained in all cases. Two cases showed impingement syndrome of the proximal portions of Steinmann pins, which were managed by early removal of the metal. One case developed operative wound infection, which were managed by antibiotics therapy, irrigation and secondary closure. CONCLUSION: Internal fixation using modified Steinmann pins and tension band wiring technique for proximal humeral fracture, with osteoporosis, makes complete union of fracture, minimizes risk of complications, and enables early rehabilitation by rendering relatively rigid fixation.


Subject(s)
Anti-Bacterial Agents , Bone Density , Fractures, Comminuted , Osteoporosis , Rehabilitation , Shoulder Fractures , Wound Infection
19.
Article in Korean | WPRIM (Western Pacific) | ID: wpr-36066

ABSTRACT

PURPOSE: To evaluate the results between open reduction and internal fixation with the plate and percutaneous reduction by towel clip and intramedullary fixation with Steinmann pin for clavicle shaft fractures in adult. MATERIALS AND METHODS: We have studied the results in 33 cases with the plate, 35 cases with the Steinmann pin among total 68 cases of clavicle shaft fracture. The patients were followed up over a period of at least 12 months. The final postoperative outcome was analyzed with the clinical outcomes using Kang's criteria, radiological union time and operation time. RESULTS: The clinical outcome that was good or excellent according to the Kang's criteria showed a distribution of 88% in the group using the plate with 29 cases out of total 33 cases, 91% in the group using the Steinmann pin with 32 cases out of total 35 cases. The mean radiological union time was 8.9 weeks in the group using the plate, 9.1 weeks in the group using Steinmann pin. The mean operation time was 72 minutes in the group using the plate, whereas was 18 minutes in the group using Steinmann pin. CONCLUSION: In the treatment of adult clavicle shaft fracture, two groups did not show a significant statistical difference in clinical and radiological outcomes. However, the operation time and postoperative functional recovery was significantly shorter and faster in the group using Steinmann pin. Additionally economic and cosmetic aspect was more satisfactory in the group using Steinmann pin.


Subject(s)
Adult , Humans , Clavicle
20.
Article in Korean | WPRIM (Western Pacific) | ID: wpr-226089

ABSTRACT

PURPOSE: To evaluate the clinical and radiological results of the treatment of mid-shaft clavicular nonunions using intramedullary fixation with threaded Steinmann pin and bone grafting. MATERIAL AND METHODS: In 16 patients treated with intramedullary fixation of threaded Steinmann pin and autogenous iliac bone grafting for the mid-shaft clavicular nonunions, 10 patients with follow-up over 1 year were investigated. All patients (10 clavicle fractures) underwent conservative treatment initially. The average age of patients was 56 years old (range, 18~70 years old). Eight cases were atrophic nonunions, two hypertrophic. A clinical assessment was evaluated postoperatively after 5 months according to the evaluation method of Kona et al. RESULTS: According to the evaluation method of Kona et al, four cases achieved excellent results, five cases good, and one case achieved a fair result. The average period until bony union was 9 weeks (range, 7~12.5 weeks) without infection, pin migration or breakage. One case showed skin irritation by lateral margin of Steinmann pin, which was subsided by pin removal after bony union. CONCLUSION: We obtained satisfactory results and have concluded that intramedullary fixation with threaded Steinmann pin and bone grafting could appropriately treat nonunions of the mid-clavicular fracture occurred after conservative treatment, because it minimizes soft tissue injury, gets relatively stable fixation and early ROM, predicts early bone union, facilitates pin removal under local anesthesia.


Subject(s)
Humans , Middle Aged , Anesthesia, Local , Bone Transplantation , Clavicle , Follow-Up Studies , Skin , Soft Tissue Injuries
SELECTION OF CITATIONS
SEARCH DETAIL
...