Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 1.657
Filter
1.
Wideochir Inne Tech Maloinwazyjne ; 19(1): 100-106, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38974762

ABSTRACT

Introduction: Endovascular aortic repair (EVAR) is nowadays a widespread method of managing abdominal aortic aneurysm (AAA). Low-profile stent grafts (LPSGs) enable treatment of patients with complex and anatomically challenging aneurysms, and facilitate a percutaneous and thus less invasive procedure. Aim: To assess the outcomes of EVAR with low-profile versus standard-profile stent grafts (SPSGs). Material and methods: Thirty-one patients with abdominal aortic aneurysms (AAA) were treated by endovascular aortic repair (EVAR) using LPSGs. The control group of patients treated with SPSGs was matched with MedCalc software. The clinical records and the preoperative and follow-up computed tomography angiography of patients who underwent endovascular treatment of AAA were included in this study. Results: Patients in the LPSG group had significantly more often low access vessel diameter (< 6 mm) compared to the SPSG group (38.7% vs. 6.7%, p = 0.003). In 1-year follow-up, there was no rupture, no infection, no conversion to open repair and no aneurysm-related death. Five secondary interventions were necessary in the SPSG group and only 1 in the LPSG group (p = 0.09). Type of stent graft was not a risk factor of perioperative complications, presence of endoleak or reintervention (p > 0.05). Risk factors for perioperative complications were COPD and conical neck (OR = 6.3, 95% CI: 1.5-25, p = 0.01 and OR = 6.2, 95% CI: 1-39.76, p = 0.04). The risk factor for endoleak was lower maximal aneurysm diameter. The risk factor for reintervention was proximal neck diameter (OR = 0.77, 95% CI: 0.-0.97, p = 0.03). Conclusions: Our study showed that use of LPSGs is a safe and viable method for patients with narrow access vessels who are not eligible for standard-profile systems.

2.
Cardiovasc Diagn Ther ; 14(3): 367-376, 2024 Jun 30.
Article in English | MEDLINE | ID: mdl-38975006

ABSTRACT

Background: Single-branched stent grafts and the chimney technique are widely used in the treatment of type B aortic dissection (TBAD). The main objective of this study was to compare the outcomes of single-branched stent grafts and the chimney technique in the treatment of TBAD. Methods: From January 2019 to December 2021, the retrospective cohort study contained a cohort of 91 patients with TBAD undergoing thoracic endovascular aortic repair (TEVAR) using single-branched stent grafts and the chimney technique. Group A included 55 patients treated with single-branched covered stents, and Group B included 36 patients treated with the chimney technique. We compared the effects of the procedures on peri-/post-operative outcomes between the two groups. The primary endpoint is clinical death, and the secondary endpoints include the patency of branch stents, the incidence of cerebral infarction, false lumen thrombosis, and the proportion of paraplegia. Results: For the baseline data, the two groups of patients show no differences in terms of age, gender, and associated symptoms. All procedures were successfully performed in both groups. The median follow-up period was 17.6 months (range, 10-34 months). During TEVAR, 5 (9.1%) type I endoleaks occurred in group A, and 11 (30.6%) occurred in group B (P<0.05). During follow-up, there were 2 cases (3.6%) of paraplegia and 1 case (1.8%) of cerebral infarction in Group A, while Group B had 1 case (2.8%) of paraplegia. Three patients in group B reported retrograde type A aortic dissection (RTAD), and 1 of them died (2.8%); however, there were no RTAD cases in group A. Complete thrombosis of the false lumen in the thoracic aorta was observed in 45.5% (25/55) of patients in group A and in 41.7% (15/36) in group B (P=0.72). No significant difference in the thrombosis-volume ratio in the whole false lumen was found during follow-up between group A (81.0%±2.9%) and group B (81.8%±2.6%; P=0.23). Conclusions: Branched stent grafts can be used in cases with insufficient proximal landing zones and reduce the occurrence of type 1 endoleak compared to the chimney technique. This may help to prevent RTAD. Further research, including more cases and longer follow-up periods, is needed to substantiate these results.

3.
CVIR Endovasc ; 7(1): 53, 2024 Jul 08.
Article in English | MEDLINE | ID: mdl-38976091

ABSTRACT

BACKGROUND: The Viabahn endoprosthesis has become a vital option for endovascular therapy, yet there is limited long-term data on its effectiveness for peripheral aneurysm repair. This study aimed to evaluate the safety, technical and clinical success, and long-term patency of the Viabahn endoprosthesis for treating femoropopliteal aneurysms. METHODS: This retrospective tertiary single-center study analyzed patients who underwent a Viabahn endoprosthesis procedure for femoropopliteal aneurysm repair from 2010 to 2020. Intraoperative complications, technical and clinical success rates, and major adverse events (MAE, including acute thrombotic occlusion, major amputation, myocardial infarction, and device- or procedure-related death) at 30 days were assessed. Incidence of clinically-driven target lesion revascularisation (cdTLR) was noted. Patency rates were evaluated by Kaplan-Meier analysis. RESULTS: Among 19 patients (mean age, 72 ± 12 years; 18 male, 1 female) who underwent aneurysm repair using the Viabahn endoprosthesis, there were no intraoperative adverse events, with 100% technical and clinical success rates. At the 30-day mark, all patients (19/19, 100%) were free of MAE. The median follow-up duration was 1,009 days [IQR, 462-1,466]. Popliteal stent graft occlusion occurred in 2/19 patients (10.5%) after 27 and 45 months, respectively. Consequently, the primary patency rates were 100%, 90%, 74% at 12, 24, and 36-72 months, respectively. Endovascular cdTLR was successful in both cases, resulting in sustained secondary patency at 100%. CONCLUSION: The use of Viabahn endoprostheses for femoropopliteal aneurysm repair demonstrated technical and clinical success rates of 100%, a 0% 30-day MAE rate, and excellent long-term patency.

4.
Article in English | MEDLINE | ID: mdl-38955816

ABSTRACT

PURPOSE: To evaluate the safety and performance of Wrapsody™, a cell-impermeable endoprosthesis (CIE), for treating hemodialysis vascular access outflow stenosis. MATERIALS AND METHODS: Investigators retrospectively analyzed 113 hemodialysis patients treated with a CIE (11/2021-12/2022) across four centers in Brazil. De novo or restenotic lesions were treated. The primary efficacy outcome measure was target lesion primary patency (TLPP) at 1, 3, 6, and 12 months; the primary safety outcome measure was the absence of serious local or systemic adverse events within the first 30 days post-procedure. Secondary outcome measures included technical and procedural success, access circuit primary patency (ACPP), and secondary patency at 1, 3, 6, and 12 months post-procedure. RESULTS: Thirty-nine patients (34.5%) had thrombosed access at the initial presentation, and 38 patients (33.6%) presented with recurrent stenosis. TLPP rates at 1, 3, 6, and 12 months were 100%, 96.4%, 86.4%, and 69.7%, respectively. ACPP rates were 100% at 1 month, 89.2% at 3 months, 70.9% at 6 months, and 56.0% at 12 months. The target lesion secondary patency rates at 1, 3, 6, and 12 months were 100%, 97.3%, 93.6%, and 91.7%, respectively. In the adjusted multivariate Cox regression analysis, male sex and endoprosthesis with diameters of 10, 12, 14, and 16 mm were associated with improved primary patency rates. No localized or systemic serious adverse event was observed through the first 30 days post-procedure. CONCLUSION: The CIE evaluated in this study is safe and effective for treating peripheral and central outflow stenoses in hemodialysis vascular access. LEVEL OF EVIDENCE: Level 2b, cohort study.

5.
Article in English | MEDLINE | ID: mdl-38876370

ABSTRACT

OBJECTIVE: To compare and evaluate early and midterm outcomes of a "no cross" novel approach with short tip vs. standard tip introducer systems for all distal components to prevent target vessel bridging stent kink or collapse during fenestrated endovascular aortic repair (FEVAR). METHODS: A retrospective analysis was conducted on all patients who underwent FEVAR at a tertiary referral centre between October 2016 and July 2022. The inclusion criterion was the use of renal artery fenestrations. Patients who had chronic dissections were included. Endpoints were analysed in two groups comprising the "no cross" group and the standard group, with all cases being consecutive in their respective groups. Cone beam computed tomography was used intra-operatively in all cases, and post-operative compute tomography angiograms and re-interventions were reviewed. Primary endpoints included technical success, intra-operative adjunctive procedures, adverse events related to the fenestration, and re-interventions, while secondary endpoints were secondary interventions and overall mortality. RESULTS: A total of 70 patients (35 in each group) were enrolled in the study, with 64 (91%) having juxta-renal aneurysms. There were no differences in demographics, cardiovascular risk factors, or aneurysm characteristics between the two groups. The "no cross" group demonstrated a significantly higher technical success rate (100% in all cases) compared with the standard group (29 cases, 83%; p = .010). Additionally, there were statistically significantly fewer intra-operative adjunctive procedures required in the "no cross" group (1.5% of fenestrations) compared with the standard group (8.2% of fenestrations) (p = .013). Overall median follow up was 32 months (interquartile range 22, 62 months). CONCLUSION: Implementation of a novel "no cross" concept during FEVAR, utilising a short dilator introducer tip on the distal bifurcated component and iliac extensions, significantly reduces intra-operative fenestration related adverse events and enhances technical success. Further studies with larger patient populations and longer follow up are needed to confirm these findings.

6.
JTCVS Tech ; 25: 8-18, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38899088

ABSTRACT

Objective: This study aims to assess the feasibility and effectiveness of physician-modified fenestrated stent grafts (PMEGs) in treating type 1a endoleak after conventional thoracic endovascular aortic repair (TEVAR) in aortic arch pathologies. Methods: Patients who developed a type 1a endoleak after conventional TEVAR were included in the study. They underwent treatment with fenestrated PMEGs, which involved single or double fenestration for the supra-aortic trunks. Results: Twenty patients were treated with PMEGs between October 2018 and November 2023. Among them, 25% received single fenestrated PMEGs and 75% received double fenestrated PMEGs. The technical success rate was 100% for both types. Eighty percent of the PMEGs had a landing zone in zone 0, whereas 20% had a landing zone in zone 2. There were no in-hospital deaths. After 30 days, 1 patient died as the result of an aortic-related cause (retrograde dissection). The mean follow-up time was 16.5 months (range, 0-60 months). No major adverse events such as stroke or spinal ischemia were reported. No type 1 or type 3 endoleaks were observed, and one type 2 endoleaks required peripheral endovascular reintervention. Conclusions: The treatment of type 1a endoleaks using fenestrated PMEGs after conventional TEVAR for aortic arch pathologies is a viable option. It is associated with acceptable rates of early and midterm major morbidity and mortality.

7.
Comput Biol Med ; 178: 108745, 2024 Jun 19.
Article in English | MEDLINE | ID: mdl-38901185

ABSTRACT

Thoracic endovascular aortic repair (TEVAR) is a minimally invasive procedure involving the placement of an endograft inside the dissection or an aneurysm to direct blood flow and prevent rupture. A significant challenge in endovascular surgery is the geometrical mismatch between the endograft and the artery, which can lead to endoleak formation, a condition where blood leaks between the endograft and the vessel wall. This study uses computational modeling to investigate the effects of artery curvature and endograft oversizing, the selection of an endograft with a larger diameter than the artery, on endoleak creation. Finite element analysis is employed to simulate the deployment of endografts in arteries with varying curvature and diameter. Numerical simulations are conducted to assess the seal zone and to quantify the potential endoleak volume as a function of curvature and oversizing. A theoretical framework is developed to explain the mechanisms of endoleak formation along with proof-of-concept experiments. Two main mechanisms of endoleak creation are identified: local buckling due to diameter mismatch and global buckling due to centerline curvature mismatch. Local buckling, characterized by excess graft material buckling and wrinkle formation, increases with higher levels of oversizing, leading to a larger potential endoleak volume. Global buckling, where the endograft bends or deforms to conform to the centerline curvature of the artery, is observed to require a certain degree of oversizing to bridge the curvature mismatch. This study highlights the importance of considering both curvature and diameter mismatch in the design and clinical use of endografts. Understanding the mechanisms of endoleak formation can provide valuable insights for optimizing endograft design and surgical planning, leading to improved clinical outcomes in endovascular aortic procedures.

8.
Front Cardiovasc Med ; 11: 1370908, 2024.
Article in English | MEDLINE | ID: mdl-38873267

ABSTRACT

Background: The left subclavian artery (LSA) can be intentionally covered by a stent graft to acquire adequate landing zones for a proximal entry tear near the LSA during thoracic endovascular aortic repair (TEVAR). The Castor single-branched stent graft is designed to treat type B aortic dissection (TBAD) to retain the LSA during TEVAR. This study investigates clinical outcomes, aortic remodeling, and abdominal aortic perfusion patterns after TEVAR with the novel Castor device. Methods: From November 2020 to June 2023, 29 patients with TBAD involving the LSA were treated with the Castor single-branched stent graft. In-hospital clinical outcome and aortic computed tomography angiography (CTA) data were analyzed. CTA was performed preoperatively and at follow-up to observe stent morphology; branch patency; endoleak; change in true lumen (TL), false lumen (FL), and transaortic diameters; and abdominal aortic branch perfusion pattern. Results: The technical success rate was 96.6%. One failure was that the branch section did not completely enter the LSA and the main body migrated distally. No in-hospital mortality, paraplegia, or stroke occurred. During follow-up, one type Ib endoleak, four distal new entry tears, and one recurrent type A dissection arose from a new entry tear at the ascending aorta, no stent migration was observed, and the branch patency rate was 100%. At the thoracic aorta, TL diameters significantly increased, FL diameters markedly decreased, and FL was partially or completely thrombosed in most patients at follow-up. At the abdominal aorta, we observed 33.3% of TL growth and 66.7% of TL stabilization or shrinkage. The initial TL ratio at iliac bifurcation negatively predicted abdominal TL growth after TEVAR with a cutoff of 21.0%. Of the 102 abdominal aortic branches, 94.1% of the branches showed no change in perfusion pattern, 3.9% of the branches had an increased TL perfusion, and 2.0% of the branches had an increased FL contribution. Conclusion: The Castor unibody single-branched stent graft offers an efficient endovascular treatment for TBAD involving the LSA. TEVAR with the Castor device effectively induced thoracic FL thrombosis and thoracic TL enlargement and resulted in abdominal TL growth when the initial TL ratio at iliac bifurcation is less than 21.0%. Abdominal aortic branch perfusion patterns remain relatively stable after TEVAR with the Castor stent graft.

9.
J Endovasc Ther ; : 15266028241258401, 2024 Jun 19.
Article in English | MEDLINE | ID: mdl-38898697

ABSTRACT

INTRODUCTION: The treatment of acute type B aortic dissection (ATBAD) is currently a challenge for vascular surgeons, because of the early morbidity and mortality rates and the high risk of late aortic events up to 50% at 5 years. This study presents the initial outcomes of ATBAD treatment using optimal medical therapy alone or combined with proximal entry tear stent-graft coverage. Additionally, it provides an analysis of the evolution of the aortic diameter and its clinical consequences during the chronic phase in each group. MATERIALS AND METHODS: Conducted as a retrospective, single-center study, we enrolled all consecutive ATBAD patients (n=130) treated between 2008 and 2020. The primary analysis studies the entire patient cohort based on their initial management approach, namely, medical treatment alone for uncomplicated ATBAD (n=67) or combined with stent-graft entry tear coverage (n=63). We also conducted a subgroup analysis to investigate factors associated with disease progression in the medical management group. RESULTS: Median follow-up was 29.5 months. During this time aneurysmal evolution was observed in: 42.4% of cases in the medical group compared with 21.8% in the stent-graft group, primarily affecting the thoracic aorta. The stent-graft group exhibited significant aortic remodeling, with a decrease in false lumen (FL) and thoracic aortic diameters. Initial aortic diameter ≥40 mm and FL ≥22 mm were independent risk factors for aneurysmal degeneration. Five-year survival was consistent at 76.1% in both groups. CONCLUSION: This study confirms the safety and efficacy of stent-graft entry tear coverage for ATBAD. Initial thoracic endovascular aortic repair (TEVAR) appears to reduce late aortic events by promoting aortic remodeling. Considering TEVAR's safety and potential to prevent late aortic complications, it may be considered for uncomplicated ATBAD patients with an initial aortic diameter ≥40 mm or an FL ≥22 mm. CLINICAL IMPACT: This study validates the efficacy and safety of using endovascular stent grafts to seal the proximal entry tear in cases of acute type B aortic dissections, compared to optimal medical therapy. Aortic remodelling significantly benefits from endovascular stent graft coverage of the proximal entry tear. Given the heightened risk of late aortic events observed in the medical therapy cohort, there appears to be a necessity for including endovascular interventions in the management of uncomplicated acute type B aortic dissections, particularly when aortic diameter is ≥40 mm and false lumen diameter is ≥22 mm.

10.
J Endovasc Ther ; : 15266028241258659, 2024 Jun 16.
Article in English | MEDLINE | ID: mdl-38880997

ABSTRACT

PURPOSE: The aim of this study was to present the covered endovascular reconstruction of the iliac artery bifurcation (CERIB) technique as a revascularization option for aorto-iliac occlusive disease (AIOD) involving the iliac artery bifurcation. METHODS: This was a retrospective single-center study including all patients undergoing a CERIB procedure from January 2021 until December 2022. Covered endovascular reconstruction of the iliac artery bifurcation procedures were performed percutaneously with bilateral femoral access, excepting cases where simultaneous open femoral artery reconstruction was required due to the extension of peripheral arterial occlusive disease. Standard patient, procedural, and follow-up (FU) data including survival and arterial reinterventions were gathered and analyzed. RESULTS: A total of 13 patients were included (11/13 male, median age=70 [60-76] years). Additional open and/or endovascular procedures included endarterectomy of the femoral bifurcation (n=6), rotational atherectomy (n=2), and 1 axillary artery cutdown for upper limb access (n=1). Median operating time was 2.9 hours (1.5-4.9 hours); median radiation duration and dose were 28.4 (14.3-63.3 minutes) and 4090.6 (384.4-9430.1 cGray/cm2), respectively. The stent grafts used for CERIB were BeGraft peripheral n=31, BeGraft Aortic n=4 and BeGraft peripheral plus n=1 (Bentley InnoMed GmbH, Hechingen, Germany). In 2 patients with prior stenting of the common iliac artery (CIA), only the internal and external iliac arteries (IIA and EIA) were treated in this study, and in 2 cases, additional uncovered stents were required for relining. Technical success was 100%. During a midterm FU (median 18 [4-31] months), 2 patients died from cardiovascular reasons and 1 patient with prior iliac stenting required reinterventions for recurring occlusion. CONCLUSION: Covered endovascular reconstruction of the iliac artery bifurcation is a straightforward option for treating AIOD involving the iliac artery bifurcation that allows preservation of internal iliac artery perfusion and shows good early and midterm results. Prior iliac artery stenting may be a risk factor for early occlusion after CERIB. CLINICAL IMPACT: Aorto-iliac occlusive disease with involvement of the internal iliac artery is encountered regularly in vascular surgical practice, but the internal iliac artery is often not included in the revascularization strategy. The present article will increase the awareness for the relevance of including the internal iliac artery in revascularization strategies and presents CERIB as another method to be added to the armamentarium of (endo-)vascular surgeons and interventionalists.

11.
J Endovasc Ther ; : 15266028241261661, 2024 Jun 16.
Article in English | MEDLINE | ID: mdl-38881034

ABSTRACT

PURPOSE: The iliac veins are the least frequent location for venous aneurysms, with only a few cases described globally. The etiology and clinical presentation of this extremely rare entity is diverse and unclear and no treatment consensus has been reached yet. Our purpose is to present an interesting iliac vein aneurysm (IVA) case that we treated in our department, with a brief review of the literature. CASE REPORT: We report a case of a 74-year-old male patient with a giant, 55 mm in diameter, asymptomatic, right common IVA, with concurrent aplasia of the left common iliac vein and an extensive network of venous collaterals. The patient was treated, under general anesthesia, with total endovascular iliocaval reconstruction through implantation of a 32 × 100 mm thoracic aortic tubular Ankura stent graft. The computed tomography venography at first-month follow-up showed the complete exclusion of the IVA, without any endoleak and the patient remains up to date free of symptoms and thromboembolic events. CONCLUSION: Twelve cases of endovascular treatment of IVA have been reported so far, and our case is the first with implantation of a thoracic aortic stent graft. Our results suggest that this technique is safe, effective, and may be considered for appropriately selected patients. CLINICAL IMPACT: This is the first case with total endovascular repair of an iliac vein aneurysm with contralateral iliac vein aplasia through endovenous implantation of a thoracic aortic stent-graft. Our results suggest that this technique is safe and effective and thus, may be considered for appropriately selected cases.

12.
J Neuroendovasc Ther ; 18(4): 126-129, 2024.
Article in English | MEDLINE | ID: mdl-38721620

ABSTRACT

Objective: Infection after carotid artery stenting (CAS) is rare. We report two dialysis cases of delayed stent infection associated with a carotid dual-layer stent (DLS), which occurred several months after deployment of the stent. Case Presentations: Case 1: A 74-year-old man receiving dialysis underwent CAS with DLS. Three months after CAS, the patient developed a high fever, neck pain, and neck swelling. Neck CT and carotid ultrasonography (CUS) indicated an abscess around the inserted DLS. The patient was treated with antibiotic agents and fully recovered. Case 2: A 73-year-old man receiving dialysis underwent CAS with DLS. Two months after CAS, this patient also developed a high fever, neck pain, and neck swelling. Contrast-enhanced neck CT indicated inflammatory effusion with an abscess and a giant infectious pseudoaneurysm. Endovascular stent graft reconstruction was employed urgently under antibiotic therapy to prevent its rupture. However, intracranial hemorrhage occurred postoperatively and left hemiparesis remained. Conclusion: Delayed carotid stent infection is a rare but severe complication. The use of a DLS might be avoided during CAS for dialysis cases.

13.
J Endovasc Ther ; : 15266028241249571, 2024 May 09.
Article in English | MEDLINE | ID: mdl-38721860

ABSTRACT

PURPOSE: This study aims to explore the feasibility and effectiveness of a unilateral transfemoral access endovascular salvage technique for complex abdominal aortic aneurysms with concurrent type Ia and Ib endoleaks following previous endovascular repair. CASE REPORT: A 69-year-old female with multiple comorbidities presented with an extent IV thoracoabdominal aortic aneurysm complicated by type Ia and Ib endoleaks and chronically occluded left iliac endoprosthesis after prior endovascular repair. Given the patient's medical complexities, open explant repair was deemed high risk. The case was successfully managed using a physician-modified fenestrated/branched endograft (PM-F/BEVAR) and an iliac branch device (IBD) deployed through a single percutaneous transfemoral access. CONCLUSION: The presented case demonstrates the safety and efficacy of PM-F/BEVAR with concomitant IBD deployment via unilateral transfemoral access. This innovative approach allows endovascular salvage in cases with restricted iliofemoral access and avoids the complexities associated with upper extremity or aortic arch manipulation. While acknowledging the technical challenges, this technique offers a viable alternative for salvaging failed endovascular repairs, emphasizing the importance of real-time modifications in achieving successful outcomes. Further studies and long-term follow-up are warranted to validate the broader applicability and durability of this approach in the management of complex abdominal aortic aneurysms with multiple endoleaks. CLINICAL IMPACT: Although not the conventional approach, unilateral transfemoral access can be utilized to implant either a physician-modified fenestrated aortic endograft or an iliac branch device. Such an approach avoids complicating issues related to upper extremity access. This innovative technique may be necessary when there is a failed prior EVAR in the setting of significant contralateral iliofemoral occlusive disease. Doing both procedures in the same setting to resolve a type Ia and Ib endoleak is feasible as demonstrated in this case report. Expanding the endovascular armamentarium to address EVAR failure will be increasingly useful in the future, especially given the morbidity profile of EVAR explantation.

16.
Article in English | MEDLINE | ID: mdl-38777715

ABSTRACT

Thoracic endovascular aneurysm repair (TEVAR) has replaced open surgical repair as the treatment of choice for several aortic conditions. Despite its lower morbidity and mortality, several TEVAR-related complications can occur and some of which may necessitate surgical or endovascular re-intervention. The current article reviews common and rare complications of TEVAR procedure with emphasis on complications identifiable on cross-sectional imaging and potential pitfalls of pre-procedural planning.

17.
J Clin Med ; 13(10)2024 May 09.
Article in English | MEDLINE | ID: mdl-38792344

ABSTRACT

OBJECTIVE: In treatment of aneurysms (SAAs) and pseudoaneurysms (SAPs) of the splenic artery, endovascular coil embolization is the approach most commonly used as it is minimally invasive and safe. However, it carries a significant rate of primary failure (up to 30%) and might be complicated by splenic infarction. The use of stent grafts might represent a valuable alternative when specific anatomical criteria are respected. We report a comprehensive review on technical and clinical outcomes achieved in this setting. Methods: We performed a comprehensive review of the literature through the MedLine and Cochrane databases (from January 2000 to December 2023) on reported cases of stenting for SAAs and SAPs. Outcomes of interest were clinical and technical success and related complications. The durability of the procedure in the long-term was also investigated. Results: Eighteen papers were included in the analysis, totalling 41 patients (n = 20 male 48.8%, mean age 55.5, range 32-82 years; n = 31, 75.6% SAAs). Mean aneurysm diameter in non-ruptured cases was 35 mm (range 20-67 mm), and most lesions were detected at the proximal third of the splenic artery. Stent grafting was performed in an emergent setting in n = 10 (24.3%) cases, achieving immediate clinical and technical success rate in 90.2% (n = 37) of patients regardless of the type of stent-graft used. There were no procedure-related deaths, but one patient died in-hospital from septic shock and n = 2 (4.9%) patients experienced splenic infarction. At the last available follow-up, the complete exclusion of the aneurysm was confirmed in 87.8% of cases (n = 36/41), while no cases of aneurysm growing nor endoleak were reported. None of the patients required re-intervention during follow-up. Conclusions: When specific anatomical criteria are respected, endovascular repair of SAAs and SAAPs using stent grafts appears to be safe and effective, and seems to display a potential advantage in respect to simple coil embolization, preserving the patient from the risk of end-organ ischemia.

18.
J Vasc Surg ; 2024 May 13.
Article in English | MEDLINE | ID: mdl-38750942

ABSTRACT

OBJECTIVE: Prevention of late type Ia endoleaks is the main concern in thoracic endovascular aortic aneurysm repair (TEVAR) for thoracic aortic aneurysm. Since 2017, we have performed zone 0 TEVAR with proximal fixation augmentation using a Najuta thoracic fenestrated stent graft in addition to zone 2 TEVAR for distal arch aneurysms. We report the early and midterm outcomes of TEVAR performed using this strategy. METHODS: This single-center retrospective study enrolled 386 cases of TEVAR for thoracic aortic disease between January 2013 and December 2020. Patients with thoracic aortic aneurysm treated by TEVAR landing at zone 2 was referred to as the standard group, whereas those treated by TEVAR landing at zone 0 using a Najuta fenestrated stent graft in addition to zone 2 TEVAR was referred to as the augmentation group. We retrospectively compared the clinical outcomes between the two groups. The primary end point was secondary intervention for postoperative type Ia endoleaks. Secondary end points were technical success, aneurysm-related death, and major adverse events (MAEs), including stroke, paraplegia, endoleaks, and secondary interventions. RESULTS: We performed TEVAR in 41 and 30 cases in the standard and augmentation groups, respectively. The mean aneurysm sizes in the standard and augmentation groups were 54.5 and 57.3 mm (P = .23), and the proximal neck lengths were 16.8 and 17.4 mm (P = .65), respectively. The anatomical characteristics seemed to be similar in both groups. The technical success rate in both groups was 100%. Three cases in the standard group had MAEs, including two stroke and one brachial artery pseudoaneurysm; whereas two cases had MAEs in the augmentation group, including one stroke and one paraplegia. There was no 30-day mortality or retrograde type A dissection in both groups. The mean observation periods in the standard and augmentation groups were 46 months (range, 1-123 months) and 35 months (range, 1-73 months), respectively. At 36 and 60 months after the procedure, the freedom from aneurysm-related death was 97.6% and 97.6% in the standard group, 100.0% and 100.0% in the augmentation group (P = .39); and the freedom from reintervention for type Ia endoleaks was 79.2% and 65.2% in the standard group, 100.0% and 100.0% in the augmentation group (P = .0087). A statistically significant decrease in reinterventions for type Ia endoleaks was observed in the augmentation group. CONCLUSIONS: Proximal fixation augmentation using the Najuta fenestrated stent graft during TEVAR for distal arch aneurysm is effective in preventing the postoperative late type Ia endoleaks.

19.
Cureus ; 16(4): e57707, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38711730

ABSTRACT

We discuss a rare case of Stanford type A aortic dissection (TAAD) occurring several months after endovascular aneurysm repair (EVAR) of the abdominal aortic and the common iliac artery (CIA) aneurysms. The patient underwent urgent surgery for TAAD treatment but died on the table due to intractable bleeding. We conclude that TAAD was likely unrelated to the initial EVAR procedure but rather to atherosclerosis, hypertension, and prior aortic valve replacement. Only a few cases in the literature report TAAD and total collapse of the abdominal aortic stent graft.

20.
J Endovasc Ther ; : 15266028241251985, 2024 May 06.
Article in English | MEDLINE | ID: mdl-38708984

ABSTRACT

PURPOSE: The treatment of thoracoabdominal aortic aneurysms (TAAAs) using branched endovascular aortic repair (BEVAR) is safe and effective. During deployment, the superior mesenteric artery (SMA) branch can unintentionally open into the celiac trunk (CT) ostium and switched catheterization of the SMA from the CT branch and the CT from the SMA branch can be used as an alternative technique in these cases. This study aimed to investigate the outcome of exchanging the intended target vessels (TVs) for the CT and SMA branches during BEVAR. MATERIALS AND METHODS: A single-center retrospective analysis of patients with TAAAs who underwent BEVAR, using off-the-shelf or custom-made devices (CMDs), with an unintended exchange of TVs for the CT and SMA branches was performed. RESULTS: Between 2014 and 2023, 397 patients were treated with BEVAR for TAAA. Eighteen (4.5%) of those patients were treated with an exchange of TVs for the CT and SMA branches. T-branch was used in 9 cases (50%) and the remaining patients were treated with CMDs. Twelve patients were treated electively, 3 were symptomatic and 3 presented with rupture. Of 36 mesenteric TVs in those 18 patients, 34 (94%) were catheterized successfully, including all 18 SMAs and 16 of the 18 CTs. No branch stenosis or occlusion of the switched mesenteric TVs was detected during follow-up. During 30-day follow-up, 3 patients died and during a median follow-up of 3 (interquartile range [IQR]: 1-15) months 3 more patients died. None of the deaths or the 2 unintended reinterventions was induced by the mesenteric TV exchange. The median hospital stay was 14 (IQR: 9-22) days with a median of 4 (IQR: 2-11) days at the intensive care unit. CONCLUSION: The exchange of the mesenteric TVs for the CT and SMA branches during BEVAR with off-the-shelf and CMD endografts is feasible with good TV patency and freedom from TV-related reinterventions. This alternative technique should be considered in selected cases when direct catheterization via the intended branch is deemed more time-consuming or not feasible. CLINICAL IMPACT: This is the first description of using an exchange of target vessels for the celiac trunk and the superior mesenteric artery branches in patients with thoracoabdominal aortic aneurysms undergoing BEVAR, using off-the-shelf or custom-made devices. The high success rate as well as the good clinical results without any branch stenosis or occlusion during follow-up highlight the feasibility of this alternative technique. It could help in challenging cases when catheterization of the intended target vessels is not possible or too time consuming, resulting in higher success rates of BEVAR and better clinical results.

SELECTION OF CITATIONS
SEARCH DETAIL
...