Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters










Language
Publication year range
1.
Braz. j. oral sci ; 9(1): 11-15, Jan.-Mar. 2010. ilus, tab, graf
Article in English | LILACS, BBO - Dentistry | ID: lil-578039

ABSTRACT

Aim: To evaluate the occurrence of microstrain around morse taper implants in straight configuration under axial load in a cast monoblock framework. Methods: Three implants were inserted in a polyurethane block and microunit abutments were installed on the implants with 20 Ncm torque. Plastic and machined copings were adapted on the preset waxing to fabricate the framework (n=5). Four strain gauges were attached on the upper surface of the block and then each framework was tightened on the abutments and a vertical load of 30 kg was applied to five points of the framework. Results: The data obtained in the strain gauge analysis were subjected to twoway ANOVA and Tukey’s test (=0.05). There was statistically significant difference (p=0.0222) for the factor application point and the mean microstrain values were: application point B 402,04µ, point A 401.21µ, point E 390.44µ, point D 341.76µand point C 309.19 µ. Conclusions: There was no microstrain difference between plastic and machined copings during axial loading. Difference in the application point was observed, but remained within bone physiological limits.


Subject(s)
Dental Implants , Dental Prosthesis, Implant-Supported , Dental Stress Analysis , Denture, Partial, Fixed , Analysis of Variance , Dental Abutments , Materials Testing , Stress, Mechanical
SELECTION OF CITATIONS
SEARCH DETAIL
...