Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 40
Filter
1.
Am J Sports Med ; 52(6): 1439-1448, 2024 May.
Article in English | MEDLINE | ID: mdl-38551128

ABSTRACT

BACKGROUND: Even though arthroscopic rotator cuff repair is recognized as a standard treatment option, the risk of postoperative retear is a major concern. PURPOSE: To evaluate the effect of porcine-derived absorbable patch-type atelocollagen during arthroscopic rotator cuff repair. STUDY DESIGN: Randomized controlled trial; Level of evidence, 1. METHODS: A total of 64 patients with rotator cuff tears diagnosed on magnetic resonance imaging (MRI) were enrolled prospectively from November 2020 to December 2021. Both groups had repairs using the suture bridge technique. For the atelocollagen group, before securing the lateral anchors, we inserted porcine-derived absorbable patch-type atelocollagen between the footprint and the tendon. On postoperative day 2, the patients underwent MRI to confirm containment of the patch-type atelocollagen. At 6 months and 1 year postoperatively, the signal intensity of the repaired tendon was assessed using MRI. Patients were evaluated using the Constant score as the primary outcome, along with the visual analog scale for pain; range of motion; American Shoulder and Elbow Surgeons score; University of California, Los Angeles, score; and Korean Shoulder Score preoperatively and at 2, 3, 6, and 12 months postoperatively. RESULTS: No significant changes in the Constant score as primary outcome, pain or other functional scores, and range of motion were observed between the groups at 1 year postoperatively. The patch-type atelocollagen was confirmed to be contained by the time-zero MRI scan taken 2 days postoperatively. Among the 55 patients included in final analysis, 12 retear cases were recorded (21.8% retear rate). A significantly lower retear rate was found in the atelocollagen group, as 3 cases were observed in this group (10.3%) and 9 cases were observed in the conventional repair group (34.6%) (P = .048). CONCLUSION: The Constant score was not different between the groups. The retear rate after rotator cuff repair was significantly lower in the group that received porcine-derived absorbable patch-type atelocollagen compared with in the conventional group. REGISTRATION: KCT0005184 (Clinical Research Information Service [CRIS]; https://cris.nih.go.kr).


Subject(s)
Absorbable Implants , Arthroscopy , Collagen , Rotator Cuff Injuries , Humans , Arthroscopy/methods , Male , Middle Aged , Rotator Cuff Injuries/surgery , Rotator Cuff Injuries/diagnostic imaging , Female , Prospective Studies , Collagen/therapeutic use , Animals , Aged , Magnetic Resonance Imaging , Range of Motion, Articular , Swine , Recurrence
2.
Cureus ; 16(1): e52568, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38249650

ABSTRACT

Autologous chondrocyte implantation (ACI) has been covered by insurance in Japan since April 2013, expanding the range of treatments for extensive knee cartilage damage. Initially, the periosteum was used for the fixation of cultured cartilage, but since February 2019, the introduction of collagen membranes has shortened surgery time and simplified the procedure. We report a case where we used the knotless suture bridge technique for a more straightforward and secure fixation with a collagen membrane. The patient was a 61-year-old male who experienced right knee pain a year earlier when stepping downstairs. Conservative treatment at a local hospital was ineffective, and he was referred to our department. At the initial examination, the right knee had an extension of -5° and a flexion of 130°. A simple X-ray of the right knee showed osteosclerosis with a translucent bone image at the medial femoral condyle. Weight-bearing full-length X-ray of the lower limb showed a femorotibial angle (FTA) of 186°, a hip-knee-ankle (HKA) angle of 12.5° varus, a percentage of mechanical axis (%MA) of 15%, and a medial proximal tibial angle (MPTA) of 78°, indicating a significant varus deformity. CT and MRI revealed a cartilage defect of 36 mm in length and 16 mm in width and a bone defect with a maximum depth of 15 mm at the medial femoral condyle. The patient underwent surgery for a traumatic cartilage defect of the medial femoral condyle. For the bone defect, autologous bone grafting was performed, and for the cartilage defect, ACI was done. The ACI involved fixation with a collagen membrane using 1.3 mm suture tape and BC PushLock anchor (Arthrex, Naples, Florida, United States) in a knotless suture bridge technique. Additionally, hybrid closed-wedge high tibial osteotomy (HCWHTO) was performed for alignment correction. At eight months post surgery, MRI proton density sagittal images confirmed the joint surface by the cartilage layer, and the Modified Outerbridge Cartilage Repair Assessment (MOCART) score was 80. At 12 months post surgery, the Japanese version of the Knee Injury and Osteoarthritis Outcome Score (J-KOOS) improved from 46.43 to 82.14 for symptoms, 58.33 to 83.33 for pain, 95.59 to 100 for activities of daily living (ADL), 45 to 75 for sports, and 68.75 to 87.50 for quality of life (QOL). X-rays showed an FTA of 173°, an HKA of 0°, and a %MA of 58%, indicating a favorable course. The knotless suture bridge technique for collagen membrane fixation during ACI is considered a convenient and time-saving method.

3.
Am J Sports Med ; 51(9): 2411-2421, 2023 07.
Article in English | MEDLINE | ID: mdl-37345285

ABSTRACT

BACKGROUND: Previous studies have demonstrated several prognostic factors for retear after arthroscopic rotator cuff repair (ARCR). However, studies that histologically evaluate the quality of the torn rotator cuff (RC) tendon and its association with postoperative outcomes are limited. PURPOSE: To investigate factors associated with retear after ARCR using the suture bridge (SB) technique, including the degree of histological degeneration of the RC tendon edge. STUDY DESIGN: Case-control study; Level of evidence, 3. METHODS: The authors retrospectively evaluated 187 patients who underwent ARCR for full-thickness tears using the SB technique; intraoperative biopsy samples were taken to assess the degree of histological degeneration using the Bonar score. The cohort was divided into healed (n = 165) and retear (n = 22) groups according to magnetic resonance imaging results obtained ≥6 months postoperatively. The evaluation included preoperative patient data (age, sex, symptom duration, trauma history, history of heavy manual work, smoking habit, hypertension, diabetes mellitus, and hyperlipidemia) and radiological data (Hamada classification, Patte classification, Goutallier classification, and global fatty degeneration index [GFDI]). Additionally, intraoperative data (anteroposterior tear size, Lafosse classification for concomitant subscapularis tendon tear, and long head of biceps injury) and preoperative and postoperative clinical findings (active range of motion, University of California, Los Angeles [UCLA], score) were evaluated. RESULTS: The retear rate was 11.8%. The retear group had a higher percentage of men (P = .031), higher Bonar score (P < .001), higher mean GFDI value (P = .002), higher rate of tear retraction degree (P = .010), and larger anteroposterior tear size (P = .020) than the healed group. The retear group had lower postoperative internal rotation (P = .031) and lower UCLA score (P < .001). Multivariate logistic regression analysis with a stepwise variable selection revealed anteroposterior tear size (odds ratio [OR], 2.4; 95% CI, 1.3-4.5; P = .004) and Bonar score (OR, 1.7; 95% CI, 1.3-2.4; P < .001) as independent predictors for a retear. CONCLUSION: The results indicate that end-stage severe tendon degeneration might affect retear. Therefore, further investigation on the progression mechanisms of tendon degeneration and development of methods to assess degenerative tissue might improve clinical outcomes after ARCR.


Subject(s)
Lacerations , Rotator Cuff Injuries , Male , Humans , Rotator Cuff/surgery , Rotator Cuff Injuries/diagnostic imaging , Rotator Cuff Injuries/surgery , Retrospective Studies , Case-Control Studies , Rupture/surgery , Arthroscopy/methods , Magnetic Resonance Imaging , Tendons , Treatment Outcome , Range of Motion, Articular , Sutures
4.
J Orthop Sci ; 2023 May 24.
Article in English | MEDLINE | ID: mdl-37236874

ABSTRACT

BACKGROUND: The Fosbury flop tear (FFT) has recently been described as a rotator cuff tear that has flipped upon itself and adhered medially. FFT is known to have a high retear rate after arthroscopic rotator cuff repair. The cause of the high postoperative retear rate after arthroscopic rotator cuff repair is believed to be due to the inability to achieve anatomical reduction because of difficulties in reducing the torn tendon stump. Arthroscopic rotator cuff repairs using the triple-row technique may allow better anatomical reduction of the cuff tear when compared with the suture-bridge technique. We compared the clinical outcomes and cuff integrity of the triple-row and suture-bridge techniques in arthroscopic rotator cuff repair for FFT. METHODS: Patients with small-to-medium sized cuff tears of the supraspinatus tendon alone who were diagnosed with FFT, underwent arthroscopic rotator cuff repair, and had 2 or more years of follow-up were included. A total of 34 shoulders underwent the triple-row technique and 22 shoulders underwent the suture-bridge technique. The following were compared between the two techniques: patient background, operation time, number of anchors used during the operation, Japanese Orthopedic Association (JOA) score, active range of motion, and retear rate. RESULTS: No significant difference in patient background was found between the two techniques. Although active range of motion was significantly improved compared with preoperative scores, no significant difference was observed between techniques. The triple-row technique demonstrated a significantly higher 24-month postoperative JOA score, significantly shorter surgery time, significantly lower retear rate, and significantly larger number of anchors used during the operation. CONCLUSIONS: The triple-row technique was an effective method compared with the suture-bridge technique in cases with FFT.

5.
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi ; 37(3): 264-271, 2023 Mar 15.
Article in Chinese | MEDLINE | ID: mdl-36940982

ABSTRACT

Objective: To compare the early effectiveness of arthroscopic repair of moderate rotator cuff tears with single-row modified Mason-Allen technique and double-row suture bridge technique. Methods: The clinical data of 40 patients with moderate rotator cuff tears who met the selection criteria between January 2021 and May 2022 were retrospectively analyzed. Among them, 20 cases were repaired with single-row modified Mason-Allen suture technique (single-row group) and 20 cases with double-row suture bridge technique (double-row group). There was no significant difference in gender, age, disease duration, rotator cuff tear size, and preoperative visual analogue scale (VAS) score, Constant-Murley score, and T2* value between the two groups ( P>0.05). The VAS score, Constant-Murley score (including subjective influence, pain, flexion, internal rotation, external rotation, abduction, and muscle strength score) were compared between the two groups before operation and at 6 weeks, 3, 6, and 12 months after operation. Functional MRI and ultrashort-echo-time (UTE)-T2* technique were performed to calculate T2* value and quantitatively evaluate the healing of rotator cuff tissue; and the healing of rotator cuff was evaluated by Sugaya classification at 12 months after operation. Results: Patients in both groups were followed up 1 year. There was no complication such as muscle atrophy, joint stiffness, or postoperative rotator cuff tear. The intra-group comparison showed that the scores of pain, subjective influence, flexion, abduction, and muscle strength in Constant-Murley scores at each time point after operation in the two groups were significantly higher than those before operation, while VAS scores were significantly lower than those before operation ( P<0.05). Internal rotation, external rotation, and total score of Constant-Murley score in the two groups were lower at 6 weeks due to abduction immobilization within 6 weeks after operation, and gradually increased at 6 months after operation, with significant differences at 3, 6, and 12 months after operation when compared with those before operation and at 6 weeks after operation ( P<0.05). The T2* values of the two groups showed a downward trend over time, and there were significant differences between the two groups at other time points ( P<0.05), except that there was no significant difference between at 6 and 12 months after operation in the single-row group and between at 3, 6, and 12 months after operation in the double-row group ( P>0.05). The comparison between groups showed that the VAS score and T2* values of the double-row group were significantly lower than those of the single-row group at 6 weeks, 3 months, 6 months, and 12 months after operation ( P<0.05). The scores of subjective influence, flexion, abduction, and internal rotation in the double-row group were significantly better than those in the single-row group at 6 weeks and 3 months after operation ( P<0.05), and the external rotation score and total score in the double-row group were significantly better than those in the single-row group at 3 months after operation ( P<0.05), but there was no significant difference at 6 and 12 months after operation ( P>0.05). There was no significant difference in muscle strength and pain scores between the two groups at 6 weeks, 3 months, 6 months, and 12 months after operation ( P>0.05). There was no significant difference in the results of Sugaya classification between the two groups at 12 months after operation ( Z=1.060, P=0.289). Conclusion: The effectiveness of arthroscopic repair of moderate rotator cuff tears with modified Mason-Allen technique and double-row suture bridge technique is satisfactory, but suture bridge technique is helpful to the early rehabilitation training of shoulder joint and the recovery of motor function of patients.


Subject(s)
Rotator Cuff Injuries , Humans , Rotator Cuff Injuries/surgery , Retrospective Studies , Arthroscopy/methods , Magnetic Resonance Imaging , Suture Techniques , Pain/surgery , Treatment Outcome
6.
J Shoulder Elbow Surg ; 32(5): 909-916, 2023 May.
Article in English | MEDLINE | ID: mdl-36796716

ABSTRACT

BACKGROUND: The purpose of this study was to investigate the efficacy of bone marrow stimulation (BMS) on the repair integrity of the rotator cuff insertion treated with arthroscopic knotless suture bridge (K-SB) rotator cuff repair. We hypothesized that BMS during K-SB repair can improve the healing of the rotator cuff insertion. METHODS: Sixty patients who underwent arthroscopic K-SB repair of full-thickness rotator cuff tears were randomly allocated to 2 treatment groups. Patients in the BMS group underwent K-SB repair augmented with BMS at the footprint. Patients in the control group underwent K-SB repair without BMS. Cuff integrity and retear patterns were evaluated by postoperative magnetic resonance imaging. The clinical outcomes included the Japanese Orthopaedic Association score, University of California at Los Angeles score, Constant-Murley score, and Simple Shoulder Test. RESULTS: Clinical and radiological evaluations were completed in 60 patients at 6 months postoperatively, in 58 patients at 1 year postoperatively, and in 50 patients at 2 years postoperatively. Both treatment groups showed significant improvements in the clinical outcome from baseline to the 2-year follow-up, but no significant differences were found between the 2 groups. At 6 months postoperatively, the retear rate at the tendon insertion was 0.0% (0 of 30) in the BMS group and 3.3% (1 of 30) in the control group (P = .313). The retear rate at the musculotendinous junction was 26.7% (8 of 30) in the BMS group and 13.3% (4 of 30) in the control group (P = .197). All retears in the BMS group occurred at the musculotendinous junction, and the tendon insertion was preserved. There was no significant difference in the overall retear rate or retear patterns between the 2 treatment groups during the study period. CONCLUSIONS: No significant differences were detected in the structural integrity or retear patterns regardless of the use of BMS. The efficacy of BMS for arthroscopic K-SB rotator cuff repair was not proven in this randomized controlled trial.


Subject(s)
Rotator Cuff Injuries , Rotator Cuff , Humans , Rotator Cuff/surgery , Prospective Studies , Bone Marrow , Treatment Outcome , Suture Techniques , Range of Motion, Articular , Rotator Cuff Injuries/surgery , Arthroscopy/methods , Magnetic Resonance Imaging , Sutures
7.
Orthop J Sports Med ; 11(1): 23259671221142242, 2023 Jan.
Article in English | MEDLINE | ID: mdl-36636031

ABSTRACT

Background: Single-row (SR) and double-row repair techniques have been described to treat rotator cuff tears. We present a novel surgical strategy of arthroscopic-assisted mini-open repair in which a locking-loop suture bridge (LLSB) is used. Purpose: To compare the functional outcomes and repair integrity of LLSB technique to the SR technique for arthroscopic-assisted mini-open repair of small to medium rotator cuff tears. Study Design: Cohort study; Level of evidence, 3. Methods: Included were 39 patients who underwent LLSB repair (LLSB group) and 44 patients who underwent SR suture anchor repair (SR group) from 2015 to 2018. We evaluated all patients preoperatively and at 3, 6, 12, and 24 months postoperatively using the visual analog scale (VAS) for pain, Oxford Shoulder Score (OSS), and American Shoulder and Elbow Surgeons (ASES) score. Also, shoulder sonography was performed at 12 months postoperatively to evaluate repair integrity using the Sugaya classification system. The independent-sample t test was used to analyze functional outcomes (VAS, OSS, and ASES scores), and the Fisher exact test was used to analyze postoperative sonography results. Results: Patients in both the LLSB and SR groups saw a significant improvement on all 3 outcome measures from preoperatively to 24 months postoperatively (P < .001 for all). However, when comparing scores between groups, only the scores at 3 months postoperatively differed significantly (VAS: P = .002; OSS: P < .001; ASES: P = .005). Shoulder sonography at 12 months postoperatively revealed no significant difference in repair integrity between the LLSB and SR groups (retear rate: 10.26% and 6.82%, respectively; P = .892). Conclusion: Better outcome scores were seen at 3-month follow-up in the LLSB group, with no difference in retear rates compared with the SR group at 12 months postoperatively. The LLSB technique was found to be a reliable technique for rotator cuff repair of small- to medium-sized tears.

8.
Am J Sports Med ; 50(8): 2219-2226, 2022 07.
Article in English | MEDLINE | ID: mdl-35604076

ABSTRACT

BACKGROUND: Because the articular layer is more prone to retraction than the bursal layer of the supraspinatus tendon, it is important to restore each layer anatomically while repairing delaminated rotator cuff tears (RCTs). PURPOSE: To compare clinical outcomes and tendon integrity between knotless layer-by-layer and conventional en masse repair techniques for delaminated RCTs. STUDY DESIGN: Cohort study; Level of evidence, 3. METHODS: We retrospectively reviewed data from 174 consecutive patients with delaminated RCTs treated by arthroscopic suture bridge repair. Only 115 patients with medium to large supraspinatus tears with delamination were included. The 33 patients treated using the knotless layer-by-layer technique (group 2) were matched 1:1 with patients treated using en masse repair with the suture bridge technique (group 1) based on propensity scores. Tendon thickness was measured on magnetic resonance imaging (MRI). Signal changes in the bursal, articular, and intratendinous layers were assessed using T2-weighted MRI. RESULTS: Postoperatively, statistically significant improvements were seen in both groups compared with preoperatively functional scores. At the final follow-up, there was a statistically significant difference in the Constant score, which was higher in group 2 than in group 1 (91.4 ± 6.0 and 84.3 ± 16.4, respectively; P = .005). There was 1 case of a retear in each group, representing a 3% retear rate. Group 2 had thicker tendons than group 1 (6.9 ± 1.1 and 6.0 ± 1.2 mm, respectively; P = .017). On T2-weighted MRI, a low signal intensity in the articular layer was more common in group 2 (P = .046). CONCLUSION: En masse repair using the suture bridge technique and the knotless layer-by-layer technique were both effective. Regarding tendon healing, no significant differences were seen in retear rates. However, superior results in terms of the Constant score, tendon thickness, and signal intensity in the articular layer were observed using the knotless layer-by-layer technique.


Subject(s)
Rotator Cuff Injuries , Arthroscopy/methods , Humans , Magnetic Resonance Imaging , Propensity Score , Rotator Cuff Injuries/diagnostic imaging , Rotator Cuff Injuries/surgery , Suture Techniques , Sutures , Treatment Outcome
9.
J Foot Ankle Surg ; 61(4): 689-694, 2022.
Article in English | MEDLINE | ID: mdl-35120804

ABSTRACT

There are several studies about arthroscopic repair techniques for the lesion of the anterior talofibular ligament. However, the research concentrating on the avulsion of the talar insertion of the anterior talofibular ligament is very rare. Among 122 patients who suffered from recurrent ankle sprain and underwent arthroscopic anterior talofibular ligament repair from October 2016 to January 2019 in our hospital, 11 patients with an avulsion of the talar insertion of this ligament were diagnosed and then treated with the arthroscopic suture-bridge repair technique in the present study. The clinical outcomes were assessed using the Karlsson-Peterson score, Ankle and hindfoot score by American Orthopedic of Foot and Ankle Society, Sefton articular stability scale and Visual Analogue Scale. The complications were recorded at the time of observation. The median value of the follow-up time was 30 (range 18-36) months. At the final follow-up, the median value of the Karlsson-Peterson score, American Orthopedic of Foot and Ankle Society ankle-hindfoot score, and Visual Analogue Scale score was 90, 90, 1, respectively. Based on the Sefton stability scale, 10 cases were in the excellent or good category. No wound infections and no neurovascular injuries were encountered, also no case required revision surgery. Only 1 patient complained about mild local irritation at the knotless anchor site. The arthroscopic suture-bridge technique could be suitable for treatment of an avulsion of the talar insertion of the anterior talofibular ligament due to satisfactory activity recovery and few complications.


Subject(s)
Joint Instability , Lateral Ligament, Ankle , Ankle Joint/diagnostic imaging , Ankle Joint/surgery , Arthroscopy/methods , Humans , Joint Instability/surgery , Lateral Ligament, Ankle/diagnostic imaging , Lateral Ligament, Ankle/injuries , Lateral Ligament, Ankle/surgery , Ligaments , Sutures
10.
Arch Orthop Trauma Surg ; 142(1): 25-31, 2022 Jan.
Article in English | MEDLINE | ID: mdl-32844306

ABSTRACT

To date two main techniques are used in arthroscopic full-thickness rotator cuff tears, the conventional knot-tying suture bridge technique and the knotless technique. We evaluated whether there is a difference in clinical outcome using both techniques. Our patients underwent arthroscopic treatment of full-thickness rotator cuff tears, and we retrospectively evaluated clinical function, strength and surgery time. Eighty-three shoulders operated between September 2012 and December 2013 were included in the study. We had nineteen patients in the knotless group, and sixty-four in the knot-tying group. In addition, we performed preoperatively radiological (magnetic resonance imaging-MRI) conformation of full-thickness rotator cuff tear in our patients. For clinical evaluation, we used Quick Disabilities of the Arm, Shoulder and Hand score (q-DASH) and the Shoulder Pain and Disability (SPADI) score, and we measured the strength of a range of motion postoperatively using a conventional dynamometer. The patients were evaluated preoperatively, and at 6, 9, and 12 months postoperatively. The follow-up period was 12 months. The scores in both treatment groups improved at twelve months follow-up, but there was no statistical difference between both groups at twelve months after surgery; q-DASH score between groups (p = 0.092) and SPADI score (p = 0.700). Similarly, there was no statistical difference between the groups in regard to strength, surgery time, and range of motion at the twelve months follow-up. Our data confirm that both techniques may be used successfully to repair full-thickness rotator cuff tears with very good functional outcome.Level of evidence IV.


Subject(s)
Rotator Cuff Injuries , Rotator Cuff , Arthroscopy , Humans , Magnetic Resonance Imaging , Retrospective Studies , Rotator Cuff/diagnostic imaging , Rotator Cuff/surgery , Rotator Cuff Injuries/diagnostic imaging , Rotator Cuff Injuries/surgery , Suture Techniques , Treatment Outcome
11.
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi ; 35(7): 829-835, 2021 Jul 15.
Article in Chinese | MEDLINE | ID: mdl-34308589

ABSTRACT

OBJECTIVE: To compare the early effectiveness of arthroscopic suture bridge technique and conventional double tunnel suture technique in the treatment of avulsion fracture of posterior cruciate ligament (PCL) insertion. METHODS: Between June 2013 and December 2018, 62 patients with tibial avulsion fracture of PCL insertion that met the criteria were selected and randomly divided into trial group (using arthroscopic suture bridge technique) and control group (using conventional double tunnel suture technique), 31 cases in each group. There was no significant difference in gender, age, injured side, cause of injury, time from injury to operation, Meyers & McKeever classification, Kellgren-Lawrence classification, and preoperative knee range of motion, difference of posterior relaxation of bilateral knee joints, International Knee Documentation Committee (IKDC) score, and Lysholm score between the two groups ( P>0.05). The operation time and IKDC score, Lysholm score, knee range of motion, the difference of posterior relaxation of bilateral knee joints (measured by KT-2000 under knee flexion of 90° and 30 lbs) were recorded and compared between the two groups before operation and at 3 and 12 months after operation. RESULTS: Both groups successfully completed the operation, and the operation time of the trial group and the control group were (61.81±6.83) minutes and (80.42±4.22) minutes respectively, showing significant difference between the two groups ( t=12.911, P=0.000). All the incisions healed by first intention, and there was no wound infection and other early postoperative related complications. All patients were followed up 13-18 months (mean, 14.6 months). The fractures in both groups healed at 3 months after operation. No knee pain, limited movement, or other complications occurred. At 3 and 12 months after operation, the IKDC score, Lysholm score, knee range of motion, and the difference of posterior relaxation of bilateral knee joints in both groups were significantly improved when compared with preoperative ones, and further improved at 12 months after operation when compared with at 3 months after operation ( P<0.05). At each time point after operation, the above indexes and the grade of the difference of posterior relaxation of bilateral knee joints in the trial group were significantly better than those in the control group ( P<0.05). CONCLUSION: Arthroscopic suture bridge technique in the treatment avulsion fracture of PCL insertion is simple and reliable, which can significantly improve the function and stability of the knee joint and obtain satisfactory early effectiveness.


Subject(s)
Fractures, Avulsion , Posterior Cruciate Ligament , Tibial Fractures , Arthroscopy , Humans , Knee Joint/surgery , Posterior Cruciate Ligament/surgery , Suture Techniques , Sutures , Tibial Fractures/surgery , Treatment Outcome
12.
Orthop J Sports Med ; 9(4): 23259671211002482, 2021 Apr.
Article in English | MEDLINE | ID: mdl-33954223

ABSTRACT

BACKGROUND: Knot-tying suture-bridge (SB) rotator cuff repair may compromise the vascularity of the repaired tendon, causing tendon strangulation and medial repair failure. The knotless SB repair technique has been proposed to overcome this possibility and decrease retear rates. PURPOSE: To compare clinical and structural outcomes and retear patterns between the knot-tying and knotless SB techniques. We hypothesized that the knotless technique would result in lower retear rates owing to the preservation of intratendinous vascularity. STUDY DESIGN: Randomized controlled trial; Level of evidence, 1. METHODS: A total of 104 patients with full-thickness rotator cuff tears were randomly and prospectively allocated to undergo knot-tying (group 1) or knotless (group 2) SB repair. Clinical outcome measures included range of motion, the visual analog scale (VAS) for pain, and the Constant score for function. Repair integrity was evaluated on magnetic resonance imaging scans using the Sugaya classification. Retears were also classified according to their pattern as type 1 (lateral) or type 2 (medial). RESULTS: Overall, 88 patients (group 1: n = 42 [mean ± SD age, 54.3 ± 9.8 years]; group 2: n = 46 [mean ± SD age, 55.8 ± 8.2 years]) were included in the final analysis. The mean ± SD follow-up period was 25.4 ± 8.3 and 23.3 ± 7.2 months for groups 1 and 2, respectively. From preoperatively to postoperatively, the mean VAS pain score improved significantly in both groups (group 1: from 7.4 ± 1.7 to 1.0 ± 1.7; group 2: from 7.1 ± 1.9 to 1.3 ± 2.0; P < .0001 for both), as did the mean ± SD Constant score (group 1: from 51.7 ± 13.4 to 86.0 ± 11.5; group 2: from 49.4 ± 18.4 to 87.2 ± 14.8; P < .0001 for both). There was no significant difference between the groups for the postoperative VAS or Constant score. The retear rate was not significantly different between the groups (19.0% [8/42] in group 1 and 28.3% [13/46] in group 2; P > .05). There was a significant difference in the type 2 failure rate (75.0% [6/8] in group 1 and 23.1% [3/13] in group 2; P = .03). CONCLUSION: Both techniques showed excellent improvement and comparable clinical outcomes, and there was no significant difference in retear rates. Consistent with previously published data, the type 2 failure rate was significantly higher with the knot-tying technique. REGISTRATION: NCT03982108 (ClinicalTrials.gov identifier).

13.
Ann Transl Med ; 9(6): 450, 2021 Mar.
Article in English | MEDLINE | ID: mdl-33850847

ABSTRACT

BACKGROUND: The suture-tendon interface turned out to be the weak point of a repaired rotator cuff. A double rip-stop (DRS) technique was developed to enhance the strength of the suture-tendon interface. The first aim of this study was to compare the suture-tendon interface strength between mesh suture and the No. 2 FiberWire (FW), which is commonly used in the clinic. The second aim was to compare the biomechanical properties of rotator cuff repair between mesh suture and No. 2 FiberWire using a typical suture-bridge (SB) and DRS techniques. METHODS: Eighteen porcine subscapularis tendon (SST) was randomly assigned to the Mesh-tendon group and FiberWire-tendon group. A single suture loop was passed through the SST with a Mesh suture or FiberWire. Thirty-two infraspinatus tendons (ISTs) were randomly assigned to four groups: SB-Mesh group: SB technique with Mesh suture, SB-FW group: SB technique with FiberWire, DRS-Mesh group: DRS technique with Mesh suture, and DRS-FW group: DRS technique with FiberWire. All repaired specimens were underwent failure testing. Failure modes, load to create a 3-mm gap, failure load, and stiffness were compared. RESULTS: There were no significant differences between the Mesh-tendon group and FiberWire-tendon group regarding the failure load, stiffness, and ultimate stress. When the same technique was used, the rotator cuff repaired with a mesh suture had the similar load to create a 3-mm gap, failure load, and stiffness compared with FiberWire. When the same suture was used, the DRS technique had a significantly higher load to create a 3-mm gap formation and failure load compared with the SB technique. CONCLUSIONS: The repair failure strength and stiffness using the mesh suture were similar to the FiberWire suture regardless of the repair techniques. However, the repair strength in the DRS technique was significantly stronger than the SB technique when the same suture material was used.

15.
Acta Radiol ; 62(8): 1025-1034, 2021 Aug.
Article in English | MEDLINE | ID: mdl-32799556

ABSTRACT

BACKGROUND: The relationship between the imaging parameters on postoperative ultrasound (US) other than repaired tendon integrity with clinical outcome such as postoperative residual pain has not been well defined. PURPOSE: To investigate whether the repaired tendon thickness and subdeltoid fluid collection after rotator cuff repair are correlated with early postoperative clinical outcome. MATERIAL AND METHODS: This retrospective study included 54 patients who underwent repair of the arthroscopic rotator cuff either by suture-bridge or single-row technique and postoperative US. We assessed the relationship between the sonographic parameters, including repaired supraspinatus tendon thickness and subdeltoid fluid collection, with the clinical outcome represented by the Korean Shoulder Scoring system (KSS) score using correlation coefficients (R). Also, the subgroup analysis was done to assess the differences by surgical technique and patients' age. RESULTS: There was a significant inverse relationship between the amount of subdeltoid fluid collection and degree of self-assessed pain improvement of the patients (P < 0.05), although every KSS category showed statistically insignificant tendency of inverse relationship with the fluid thickness. However, there was no statistically significant relationship between the thickness of repaired supraspinatus tendon and KSS scores. In patients aged >60 years, a statistically significant inverse relationship between thickness of subdeltoid fluid collection and difference value of the KSS scores in category of function was observed with both interpreters (P = 0.015 and P = 0.04, respectively). CONCLUSION: Subdeltoid fluid collection measured on US after repair of the arthroscopic rotator cuff in the early postoperative period has significant association with the patients' subjective clinical outcome.


Subject(s)
Rotator Cuff/diagnostic imaging , Ultrasonography , Age Factors , Aged , Arthroscopy/methods , Female , Humans , Male , Middle Aged , Pain, Postoperative/diagnostic imaging , Pain, Postoperative/etiology , Retrospective Studies , Rotator Cuff/pathology , Rotator Cuff/surgery , Shoulder Pain/diagnostic imaging , Shoulder Pain/etiology , Treatment Outcome , Ultrasonography/methods
16.
JSES Int ; 4(2): 352-356, 2020 Jun.
Article in English | MEDLINE | ID: mdl-32490425

ABSTRACT

BACKGROUND: The diagnosis and treatment of partial-thickness rotator cuff tears remain controversial, and only a few studies have carried out clinical evaluation and comparison based on different types of tears. The aim of this study was to compare the clinical outcomes of arthroscopic cuff repairs using the suture bridge technique in patients with articular partial-thickness rotator cuff tears (APRCTs) vs. those with bursal partial-thickness rotator cuff tears (BPRCTs). METHODS: We retrospectively evaluated 29 patients with APRCTs and 22 patients with BPRCTs who underwent arthroscopic cuff repair using the suture bridge technique with a minimum 2-year follow-up. Clinical outcomes were evaluated preoperatively and postoperatively using the visual analog scale score, Japanese Orthopaedic Association (JOA) score, Constant score (CS), active range of motion (ROM) of shoulder flexion and abduction, improvement rate for each score, and retear rate. RESULTS: The APRCT group had more women, fewer cases of subacromial decompression, and more patients whose condition changed intraoperatively and transitioned into a complete tear. Preoperatively, the JOA score, CS, ROM of shoulder flexion, ROM of shoulder abduction, and external shoulder rotation strength were lower in the APRCT group. Postoperatively, all scores improved significantly in both groups, and the JOA score, CS, and external shoulder rotation strength remained significantly lower in the APRCT group. Improvement and retear rates were not significantly different between the groups. CONCLUSIONS: The suture bridge technique significantly improved the clinical outcomes of patients with APRCTs and BPRCTs. Preoperative and postoperative functional parameters were worse in APRCT patients.

17.
Am J Sports Med ; 48(7): 1575-1582, 2020 06.
Article in English | MEDLINE | ID: mdl-32368926

ABSTRACT

BACKGROUND: Dog-ear and bird-beak deformities are common after transosseous-equivalent repair (suture bridge technique). The natural course of deformities after rotator cuff (RC) repair using the suture bridge technique is unclear. The remodeling potential of these deformities has not been investigated. PURPOSE: To evaluate remodeling and retear rates associated with deformities after RC repair. STUDY DESIGN: Cohort study; Level of evidence, 3. METHODS: Between November 2011 and February 2012, we studied 99 consecutive shoulders. All patients underwent arthroscopic RC repair via the suture bridge technique with or without additional sutures. Two groups were formed: no deformity (n= 46) and deformity (n = 53). Deformity was defined as marginal detachment and protrusion of the RC after repair, involving inappropriate compression of the suture limbs from the anchors. Tendon height was measured from the highest point of the most protruding portion of the cuff to the cortex on semi-coronal magnetic resonance imaging (MRI) scan. Change in tendon height was evaluated on MRI scan at 1 week and 6 months postoperatively. Clinical assessment at every patient visit included the American Shoulder and Elbow Surgeons (ASES) score, Constant shoulder score, and visual analog scale for pain (pVAS) score. RESULTS: No significant differences were found in age, sex, symptom duration, tear size, and preoperative ASES, Constant, and pVAS scores (P > .05) between the 2 groups. The initial tendon height was 7.4 ± 1.5 mm in the no-deformity group and 9.3 ± 2.0 mm in the deformity group. Follow-up height was 6.3 ± 2.1 mm in the no-deformity group and 6.4 ± 1.6 mm in the deformity group. Mean postoperative tendon heights were 90.1% ± 23.8% of the initial height in the no-deformity group and 73.2% ± 15.1% in the deformity group. Clinical scores (ASES, Constant, and pVAS) were not significantly different between the groups at 6 months. There were 4 shoulders in each group that experienced retearing (types 4 and 5 according to the Sugaya classification) at 6 months postoperatively. There was no difference in retear rate (P > .999). CONCLUSION: Most deformities after RC repair were remodeled with no effect on retears. Clinical outcomes were not affected by deformities.


Subject(s)
Rotator Cuff Injuries , Rotator Cuff/pathology , Suture Techniques , Arthroscopy , Cohort Studies , Humans , Magnetic Resonance Imaging , Retrospective Studies , Rotator Cuff/surgery , Rotator Cuff Injuries/diagnostic imaging , Rotator Cuff Injuries/surgery , Treatment Outcome
18.
Clin Biomech (Bristol, Avon) ; 69: 191-196, 2019 10.
Article in English | MEDLINE | ID: mdl-31374486

ABSTRACT

BACKGROUND: Rotator cuff tendon rupture after suture bridge repair occasionally occurs at the medial row, with remnant tendon tissue remaining at the footprint. While concentrated medial row stress is suspected to be involved in such tears, the optimal suture bridge technique remains controversial. METHODS: This study aimed to investigate the construct strength provided by suture bridge techniques having four different medial row configurations using artificial materials (n = 10 per group): Group 1, four-hole (two stitches per hole) knotless suture bridge; Group 2, eight-hole (one stitch per hole) parallel knotless suture bridge; Group 3, eight-hole non-parallel knotless suture bridge; and Group 4, eight-hole knot-tying suture bridge. Each construct underwent cyclic loading from 5 to 30 N for 20 cycles, followed by tensile testing to failure. The ultimate failure load and linear stiffness were measured. FINDINGS: Group 2 had the highest ultimate failure load (mean 160.54 N, SD 6.40) [Group 4 (mean 150.21 N, SD 9.76, p = 0.0138), Group 3 (mean 138.80 N, SD 7.18, p < 0.0001), and Group 1 (mean 129.35 N, SD 4.25, p < 0.0001)]. The linear stiffness of Group 2 (mean 9.32 N/mm, SD 0.25) and Group 4 (mean 9.72 N/mm, SD 0.40) was significantly higher (p = 0.0032) than that of Group 1 (mean 8.44 N/mm, SD 0.29) and Group 3 (mean 8.61 N/mm, SD 0.31). INTERPRETATION: In conclusion, increasing the number of suture-passed holes, arranging the holes in parallel, and a knotless technique improved the failure load following suture bridge repair.


Subject(s)
Arthroplasty/methods , Rotator Cuff Injuries/surgery , Rotator Cuff/surgery , Suture Techniques , Sutures , Biomechanical Phenomena , Biophysics , Humans , Humerus/diagnostic imaging , Imaging, Three-Dimensional , Male , Printing, Three-Dimensional , Rotator Cuff/diagnostic imaging , Stress, Mechanical , Tendons/surgery
19.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-734181

ABSTRACT

Objective To evaluate the efficacy of bone marrow fenestration technique used for ro-tator cuff repair at the foot-print zone of rotator cuff under arthroscopy. Methods A total of 30 patients with full-thickness rotator cuff tear ( from 3 cm to 5 cm) were enrolled for this retrospective study who had been treated at Department of Orthopaedics, The People's Hospital of North Jiangsu from January 2015 to December 2016. Of them, 15 were treated under arthroscopy with simple suture bridge technique ( SB group ) and the other 15 under arthroscopy with bone marrow fenestration and suture bridge techniques ( BMSB group ) . The 2 groups were compared in terms of visual analogue scale ( VAS ) , American Shoulder and Elbow Surgeons ( ASES ) scale, Constant scores,range of motion of the affected shoulder and rate of retear after surgery. Results All the patients received follow-up for 11 to 14 months. Significant improvements were achieved in both groups in VAS scores at 3 months ( 1.9 ± 0.6 and 0.9 ± 0.6 ) , ASES scores ( 90.7 ± 3.6 and 92.3 ± 4.2 ) and Constant scores ( 88.9 ± 2.5 and 87.4 ± 3.4 ) at the last follow-up, compared with the preoperative values ( 4.7 ± 1.1 and 4.3 ± 1.5, 58.2 ± 7.2 and 55.6 ± 4.4, and 57.3 ± 6.7 and 55.9 ± 10.3, respectively) ( P <0.05), but there were no significant differences between the 2 groups in ASES scores, Constant scores or range of motion of the affected shoulder at the last follow-up ( P> 0.05). The VAS scores at 3 months for the BMSB group (0.9 ± 0.6) were significantly lower than that for the SB group (1.9 ± 0.6) ( P <0.05). There was no significant difference either between the 2 groups in the retear rate [ 20.0% ( 3/15 ) for SB group versus 26.7% ( 4/15 ) for BMSB group ] ( P > 0.05 ) . Conclusion Application of bone marrow fenestration technique in addition to suture bridge technique can obviously relieve pain after rotator cuff repair, though it shows no advantage in functional recovery of the shoulder joint.

20.
Int Orthop ; 41(6): 1257-1263, 2017 06.
Article in English | MEDLINE | ID: mdl-28401278

ABSTRACT

PURPOSE: The aim of this study was to evaluate the early clinical outcomes of arthroscopic treatment of avulsion or comminuted fractures of the greater tuberosity (GT) using a modified suture-bridge technique. METHODS: Between February 2013 and November 2015, 14 patients with displaced or comminuted fractures of GT were arthroscopically treated using a modified suturebridge technique. Displacement of the GT fragments was > 3 mm in any plane. An analysis of follow-up results including the University of California, Los Angeles (UCLA) shoulder scale; the shoulder index of the American Shoulder and Elbow Surgeons (ASES); the simple shoulder test (SST); and shoulder range of motion (ROM), is presented. RESULTS: Mean duration of follow up is 18.9 months (range, 6-30). Mean age of patients was 62.9 years (range, 49-74). Postoperatively, the outcomes were rated as excellent, good and fair in two, 11 and one patient, respectively based on the UCLA score. At the most recent follow-up, the average UCLA score increased to 32 points, the ASES score increased to 97.5 points, and the SST score increased to 11 points. Average forward flexion was 153.6°, average abduction was 158.6°, average external rotation in the neutral position was 38.6°, and internal rotation increased to the 12th thoracic vertebral level. CONCLUSION: Early follow-up outcomes of the arthroscopic modified suture-bridge technique used for avulsion or comminuted GT fractures are promising. The technique can be used as one of the therapeutic modalities for GT fractures.


Subject(s)
Arthroscopy/methods , Fracture Fixation/methods , Fractures, Comminuted/surgery , Shoulder Fractures/surgery , Suture Techniques/adverse effects , Aged , Female , Follow-Up Studies , Humans , Male , Middle Aged , Range of Motion, Articular , Recovery of Function , Shoulder Joint/surgery , Sutures , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...