Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 374
Filter
3.
Article in English | MEDLINE | ID: mdl-39015194

ABSTRACT

Bidirectional ventricular tachycardia (BVT) is a rare form of malignant ventricular arrhythmia characterized by beat-to-beat alternation in the QRS axis. BVT is a hallmark of digitalis toxicity, but digoxin-induced BVT secondary to digoxin-diuretic interaction in cardiac surgery patients is not widely reported. We present the case of a 62-year-old woman undergoing mitral valve replacement with tricuspid annuloplasty who developed postoperative congestive heart failure and vasoplegic syndrome requiring norepinephrine, vasopressin, and loop diuretics. During postoperative care, she presented atrial fibrillation with rapid ventricular response, achieving rate control with digoxin, but later displayed hemodynamically stable BVT associated with digitalis toxicity. The case highlights the importance of physicians monitoring digoxin toxicity when prescribing digoxin to patients with a diuretic regimen, particularly loop diuretics. During digoxin-induced-BVT, supportive treatment, including discontinuing digitalis coupled with potassium and magnesium supplements, can be considered as long as digoxin-specific antibodies are unavailable, and the patient is hemodynamically stable.


La taquicardia ventricular bidireccional (TVB) es una arritmia rara caracterizada por alternancia latido a latido en el eje QRS. La TVB es característica de intoxicación digitálica; sin embargo, la TVB secundaria a interacción digoxina-diurético en pacientes posoperados de cirugía cardíaca no se ha reportado ampliamente. Presentamos el caso de una mujer de 62 años sometida a cirugía cardiaca que desarrolló falla cardiaca congestiva y síndrome vasopléjico en el posoperatorio por lo que requirió noradrenalina, vasopresina y diurético de asa. Durante la hospitalización presentó fibrilación auricular con respuesta ventricular rápida; se logró control con digoxina, pero posteriormente presentó TVB asociada a intoxicación digitálica. Este caso resalta la importancia de detectar intoxicación digitálica durante la prescripción de digoxina a pacientes con un régimen diurético, especialmente diuréticos de asa. Durante la TVB inducida por digoxina, el tratamiento de soporte se puede considerar cuando no haya disponible anticuerpos específicos para digoxina y el paciente este hemodinámicamente estable.

4.
Circ Arrhythm Electrophysiol ; : e012663, 2024 Jul 25.
Article in English | MEDLINE | ID: mdl-39051111

ABSTRACT

BACKGROUND: Differentiating wide complex tachycardias (WCTs) into ventricular tachycardia (VT) and supraventricular wide tachycardia via 12-lead ECG interpretation is a crucial but difficult task. Automated algorithms show promise as alternatives to manual ECG interpretation, but direct comparison of their diagnostic performance has not been undertaken. METHODS: Two electrophysiologists applied 3 manual WCT differentiation approaches (ie, Brugada, Vereckei aVR, and VT score). Simultaneously, computerized data from paired WCT and baseline ECGs were processed by 5 automated WCT differentiation algorithms (WCT Formula, WCT Formula II, VT Prediction Model, Solo Model, and Paired Model). The diagnostic performance of automated algorithms was compared with manual ECG interpretation approaches. RESULTS: A total of 212 WCTs (111 VT and 101 supraventricular wide tachycardia) from 104 patients were analyzed. WCT Formula demonstrated superior accuracy (85.8%) and specificity (87.1%) compared with Brugada (75.2% and 57.4%, respectively) and Vereckei aVR (65.3% and 36.4%, respectively). WCT Formula II achieved higher accuracy (89.6%) and specificity (85.1%) against Brugada and Vereckei aVR. Performance metrics of the WCT Formula (accuracy 85.8%, sensitivity 84.7%, and specificity 87.1%) and WCT Formula II (accuracy 89.8%, sensitivity 89.6%, and specificity 85.1%) were similar to the VT score (accuracy 84.4%, sensitivity 93.8%, and specificity 74.2%). Paired Model was superior to Brugada in accuracy (89.6% versus 75.2%), specificity (97.0% versus 57.4%), and F1 score (0.89 versus 0.80). Paired Model surpassed Vereckei aVR in accuracy (89.6% versus 65.3%), specificity (97.0% versus 75.2%), and F1 score (0.89 versus 0.74). Paired Model demonstrated similar accuracy (89.6% versus 84.4%), inferior sensitivity (79.3% versus 93.8%), but superior specificity (97.0% versus 74.2%) to the VT score. Solo Model and VT Prediction Model accuracy (82.5% and 77.4%, respectively) was superior to the Vereckei aVR (65.3%) but similar to Brugada (75.2%) and the VT score (84.4%). CONCLUSIONS: Automated WCT differentiation algorithms demonstrated favorable diagnostic performance compared with traditional manual ECG interpretation approaches.

5.
Circ Arrhythm Electrophysiol ; : e012814, 2024 Jul 25.
Article in English | MEDLINE | ID: mdl-39051118

ABSTRACT

BACKGROUND: During pulsed field ablation (PFA), relationships between ablation parameters (contact force [CF], number of burst pulses, impedance decrease, and electrode temperature) and lesion size in beating hearts have not been well validated. METHODS: A 7F-catheter with a 3.5-mm ablation electrode and CF sensor (ThermoCool SmartTouch SF-Dual-Energy, Biosense Webster, Inc, Irwindale, CA) was connected to a PFA system (TRUPULSE2, Biosense Webster, Inc). In 11 closed-chest swine, biphasic PFA current was delivered between the ablation electrode and the skin patch at 219 sites in left ventricle and right ventricle using 12, 18, and 24 burst pulses with 4 different levels of CF: (1) low (n=57; CF, 4-15g; median, 10g); (2) moderate (n=60; CF, 16-30g; median, 22.5g); (3) high (n=68; CF, 32-65g; median, 40g); and (4) no electrode contact (n=34), 2 mm away from the endocardium. Swine were euthanized 2 hours after ablation, and lesion size was measured using triphenyl tetrazolium chloride staining. RESULTS: All PFA lesions with electrode-myocardium contact were well demarcated with triphenyl tetrazolium chloride staining, demonstrating (1) pale central zone (contraction band necrosis with minimal coagulation necrosis), (2) dark brown zone (contraction band necrosis with hemorrhage), and (3) hyperstained red zone by triphenyl tetrazolium chloride (unaffected normal myocardium with preserved mitochondrial activity, consistent with reversible zone). Lesion depth increased significantly with increasing CF and the number of PFA burst pulses. An exponential/logarithmic formula combined with CF and the number of PFA burst pulses correlated lesion depth with high accuracy: R=0.809, P<0.0001, ±1.0-mm accuracy in 128 of 163 (79%) lesions, and ±1.5-mm accuracy in 153 of 163 (94%) lesions. Impedance decrease and electrode temperature were poor predictors of lesion size. There were no detectable lesions resulting from ablation without electrode contact. CONCLUSIONS: Acute PFA ventricular lesions demonstrate irreversible and reversible lesion boundaries. Electrode-tissue contact is required for effective lesion formation. Lesion depth increases significantly with increasing CF and PFA burst pulses. A new exponential/logarithmic formula combined with CF and the number of PFA burst pulses correlates lesion depth with high accuracy.

10.
Circ Arrhythm Electrophysiol ; 17(6): e012523, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38690665

ABSTRACT

BACKGROUND: In the PARTITA trial (Does Timing of Ventricular Tachycardia Ablation Affect Prognosis in Patients With an Implantable Cardioverter Defibrillator?), antitachycardia pacing (ATP) predicted the occurrence of implantable cardioverter defibrillator (ICD) shocks. Catheter ablation of ventricular tachycardia after the first shock reduced the risk of death or worsening heart failure. A threshold of ATPs that might warrant an ablation procedure before ICD shocks is unknown. Our aim was to identify a threshold of ATPs and clinical features that predict the occurrence of shocks and cardiovascular events. METHODS: We analyzed data from 517 patients in phase A of the PARTITA study. We used classification and regression tree analysis to develop and test a risk stratification model based on arrhythmia patterns and clinical data to predict ICD shocks. Secondary end points were worsening heart failure and cardiovascular hospitalization. RESULTS: Classification and regression tree classified patients into 6 leaves by increasing shock probability. Patients treated with ≥5 ATPs in 6 months (active arrhythmia pattern) had the highest risk of ICD shocks (93% and 86%, training and testing samples, respectively). Patients without ATPs had the lowest (1% and 2%). Other predictors included left ventricle ejection fraction<35%, age of <60 years, and obesity. Survival analysis revealed a higher risk of worsening heart failure (hazard ratio, 5.45 [95% CI, 1.62-18.4]; P=0.006) and cardiovascular hospitalization (hazard ratio, 7.29 [95% CI, 3.66-14.5]; P<0.001) for patients with an active arrhythmia pattern compared with those without ATPs. CONCLUSIONS: Patients with an active arrhythmia pattern (≥5 ATPs in 6 months) are associated with an increased risk of ICD shocks, as well as heart failure hospitalization and cardiovascular hospitalization. These data suggest that additional treatments may be helpful to this high-risk group as a preventive strategy to reduce the incidence of major events. Further prospective randomized trials are needed to confirm the benefits of early ventricular tachycardia ablation in this setting.


Subject(s)
Defibrillators, Implantable , Electric Countershock , Heart Failure , Tachycardia, Ventricular , Humans , Female , Male , Tachycardia, Ventricular/physiopathology , Tachycardia, Ventricular/diagnosis , Tachycardia, Ventricular/therapy , Tachycardia, Ventricular/mortality , Middle Aged , Aged , Risk Factors , Risk Assessment , Electric Countershock/instrumentation , Electric Countershock/adverse effects , Heart Failure/physiopathology , Heart Failure/therapy , Heart Failure/diagnosis , Heart Failure/mortality , Catheter Ablation/adverse effects , Time Factors , Treatment Outcome , Cardiac Pacing, Artificial/adverse effects
12.
Circ Arrhythm Electrophysiol ; 17(6): e012734, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38753535

ABSTRACT

BACKGROUND: Endocardial catheter-based pulsed field ablation (PFA) of the ventricular myocardium is promising. However, little is known about PFA's ability to target intracavitary structures, epicardium, and ways to achieve transmural lesions across thick ventricular tissue. METHODS: A lattice-tip catheter was used to deliver biphasic monopolar PFA to swine ventricles under general anesthesia, with electroanatomical mapping, fluoroscopy and intracardiac echocardiography guidance. We conducted experiments to assess the feasibility and safety of repetitive monopolar PFA applications to ablate (1) intracavitary papillary muscles and moderator bands, (2) epicardial targets, and (3) bipolar PFA for midmyocardial targets in the interventricular septum and left ventricular free wall. RESULTS: (1) Papillary muscles (n=13) were successfully ablated and then evaluated at 2, 7, and 21 days. Nine lesions with stable contact measured 18.3±2.4 mm long, 15.3±1.5 mm wide, and 5.8±1.0 mm deep at 2 days. Chronic lesions demonstrated preserved chordae without mitral regurgitation. Two targeted moderator bands were transmurally ablated without structural disruption. (2) Transatrial saline/carbon dioxide assisted epicardial access was obtained successfully and epicardial monopolar lesions had a mean length, width, and depth of 30.4±4.2, 23.5±4.1, and 9.1±1.9 mm, respectively. (3) Bipolar PFA lesions were delivered across the septum (n=11) and the left ventricular free wall (n=7). Twelve completed bipolar lesions had a mean length, width, and depth of 29.6±5.5, 21.0±7.3, and 14.3±4.7 mm, respectively. Chronically, these lesions demonstrated uniform fibrotic changes without tissue disruption. Bipolar lesions were significantly deeper than the monopolar epicardial lesions. CONCLUSIONS: This in vivo evaluation demonstrates that PFA can successfully ablate intracavitary structures and create deep epicardial lesions and transmural left ventricular lesions.


Subject(s)
Catheter Ablation , Heart Ventricles , Ventricular Septum , Animals , Ventricular Septum/physiopathology , Ventricular Septum/diagnostic imaging , Ventricular Septum/surgery , Catheter Ablation/methods , Catheter Ablation/instrumentation , Swine , Heart Ventricles/physiopathology , Heart Ventricles/diagnostic imaging , Heart Ventricles/surgery , Feasibility Studies , Papillary Muscles/physiopathology , Papillary Muscles/surgery , Papillary Muscles/diagnostic imaging , Time Factors , Pericardium/surgery , Pericardium/physiopathology , Cardiac Catheters , Ultrasonography, Interventional , Electrophysiologic Techniques, Cardiac , Equipment Design , Female
14.
Circ Res ; 134(8): e52-e71, 2024 Apr 12.
Article in English | MEDLINE | ID: mdl-38497220

ABSTRACT

BACKGROUND: Andersen-Tawil syndrome type 1 is a rare heritable disease caused by mutations in the gene coding the strong inwardly rectifying K+ channel Kir2.1. The extracellular Cys (cysteine)122-to-Cys154 disulfide bond in the channel structure is crucial for proper folding but has not been associated with correct channel function at the membrane. We evaluated whether a human mutation at the Cys122-to-Cys154 disulfide bridge leads to Kir2.1 channel dysfunction and arrhythmias by reorganizing the overall Kir2.1 channel structure and destabilizing its open state. METHODS: We identified a Kir2.1 loss-of-function mutation (c.366 A>T; p.Cys122Tyr) in an ATS1 family. To investigate its pathophysiological implications, we generated an AAV9-mediated cardiac-specific mouse model expressing the Kir2.1C122Y variant. We employed a multidisciplinary approach, integrating patch clamping and intracardiac stimulation, molecular biology techniques, molecular dynamics, and bioluminescence resonance energy transfer experiments. RESULTS: Kir2.1C122Y mice recapitulated the ECG features of ATS1 independently of sex, including corrected QT prolongation, conduction defects, and increased arrhythmia susceptibility. Isolated Kir2.1C122Y cardiomyocytes showed significantly reduced inwardly rectifier K+ (IK1) and inward Na+ (INa) current densities independently of normal trafficking. Molecular dynamics predicted that the C122Y mutation provoked a conformational change over the 2000-ns simulation, characterized by a greater loss of hydrogen bonds between Kir2.1 and phosphatidylinositol 4,5-bisphosphate than wild type (WT). Therefore, the phosphatidylinositol 4,5-bisphosphate-binding pocket was destabilized, resulting in a lower conductance state compared with WT. Accordingly, on inside-out patch clamping, the C122Y mutation significantly blunted Kir2.1 sensitivity to increasing phosphatidylinositol 4,5-bisphosphate concentrations. In addition, the Kir2.1C122Y mutation resulted in channelosome degradation, demonstrating temporal instability of both Kir2.1 and NaV1.5 proteins. CONCLUSIONS: The extracellular Cys122-to-Cys154 disulfide bond in the tridimensional Kir2.1 channel structure is essential for the channel function. We demonstrate that breaking disulfide bonds in the extracellular domain disrupts phosphatidylinositol 4,5-bisphosphate-dependent regulation, leading to channel dysfunction and defects in Kir2.1 energetic stability. The mutation also alters functional expression of the NaV1.5 channel and ultimately leads to conduction disturbances and life-threatening arrhythmia characteristic of Andersen-Tawil syndrome type 1.


Subject(s)
Andersen Syndrome , Humans , Mice , Animals , Andersen Syndrome/genetics , Andersen Syndrome/metabolism , Mutation , Myocytes, Cardiac/metabolism , Cardiac Conduction System Disease , Disulfides , Phosphatidylinositols/metabolism
16.
Ann Noninvasive Electrocardiol ; 29(2): e13112, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38491719

ABSTRACT

BACKGROUND: To develop a new algorithm to differentiate ventricular tachycardia (VT) from preexcited tachycardia (pre-ET) according to left bundle branch block (LBBB) and right bundle branch block (RBBB) patterns. METHODS: This study included 67 electrocardiograms (ECGs) with VT and 63 ECGs with pre-ET, collected from our hospital and through PubMed. Of those, 64 were allocated to the derivation cohort and the rest to the validation cohort. The diagnoses of the ECGs were confirmed using an electrophysiological study. Parameters and classifiers from prior algorithms along with the propagation speeds in the early portion of the QRS complex (initial deflection index) in leads V1, V6, aVR, II, and III were manually measured. The performance of the new algorithm was compared with that of prior algorithms. RESULTS: The initial deflection index in lead III was the strongest predictor of pre-ET in LBBB-pattern wide-QRS tachycardia (p = 0.003, AUC 0.805). The initial deflection index in lead V1 was the most powerful predictor of pre-ET in RBBB-pattern wide-QRS tachycardia (p = 0.001, AUC 0.848). Compared to earlier algorithms, those using the initial deflection indexes: lead III in LBBB patterns (cutoff value >0.3) and lead V1 in RBBB patterns (cutoff value ≤0.48), demonstrated superior performance in screening VT, with AUC values of 0.828. The initial deflection indexes proved effective as discriminators between VT and pre-ET in the validation cohort. CONCLUSIONS: In LBBB-pattern wide-QRS tachycardia, the early propagation speed of pre-ET was faster than that in VT. Conversely, in RBBB-pattern wide-QRS tachycardia, it was slower.


Subject(s)
Electrocardiography , Tachycardia, Ventricular , Humans , Tachycardia, Ventricular/diagnosis , Bundle-Branch Block/complications , Bundle-Branch Block/diagnosis , Diagnosis, Differential , Algorithms
18.
Open Heart ; 11(1)2024 Mar 08.
Article in English | MEDLINE | ID: mdl-38458770

ABSTRACT

The wearable cardioverter defibrillator (WCD) is becoming a more and more widely used instrument for the prevention of sudden cardiac death of patients either with a secondary prevention implantable cardioverter defibrillator indication or with a transient high risk of sudden cardiac death. Although clinical practice has demonstrated a benefit of protecting patients for a period as long as 3-6 months with such devices, the current European guidelines concerning ventricular arrhythmias and sudden cardiac death are still extremely restrictive in the patient selection in part because of the costs derived from such a prevention device, in part because of the lack of robust randomised trials.To illustrate expanded use cases for the WCD, four real-life clinical cases are presented where patients received the device slightly outside the established guidelines. These cases demonstrate the broader utility of WCDs in situations involving acute myocarditis, thyrotoxicosis, pre-excited atrial fibrillation and awaiting staging/prognosis of a lung tumour. The findings prompt expansion of the existing guidelines for WCD use to efficiently protect more patients whose risk of arrhythmic cardiac death is transient or uncertain. This could be achieved by establishing a European register of the patients who receive a WCD for further analysis.


Subject(s)
Atrial Fibrillation , Defibrillators, Implantable , Wearable Electronic Devices , Humans , Electric Countershock/adverse effects , Death, Sudden, Cardiac/etiology , Death, Sudden, Cardiac/prevention & control , Atrial Fibrillation/complications
20.
Heart ; 110(5): 313-322, 2024 Feb 12.
Article in English | MEDLINE | ID: mdl-37487695

ABSTRACT

The National Institute for Health and Care Excellence (NICE) guidelines present a synopsis of extensive internal evidence and technology reviews, with a particular focus on clinical efficacy and cost-effectiveness within the NHS in England. This approach has delivered a novel perspective on arrhythmia management, with important distinctions from other policymakers' recommendations. For example, when compared with the European Society of Cardiology (ESC) and the American Heart Association (AHA)/Heart Rhythm Society (HRS)/American College of Cardiology (ACC) guidelines on atrial fibrillation (AF), NICE advocates unique strategies regarding arrhythmia detection, stroke and bleeding risk stratification, and rhythm control (NICE CG 196). Likewise, for patients at risk of sudden cardiac death, NICE TA314 not only recommends device therapy based on New York Heart Association class and ECG findings, but also incorporates quality-adjusted life year data from analysis of key randomised controlled trials.This review examines the NICE guidelines, together with those from the AHA/HRS/ACC and ESC, on the management of AF and ventricular arrhythmias and highlights the key common features and discrepancies between these important documents.


Subject(s)
Atrial Fibrillation , Cardiology , Stroke , Humans , United States , Atrial Fibrillation/diagnosis , Atrial Fibrillation/therapy , Death, Sudden, Cardiac/etiology , Death, Sudden, Cardiac/prevention & control , England
SELECTION OF CITATIONS
SEARCH DETAIL
...