Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 127
Filter
1.
Rom J Ophthalmol ; 68(2): 158-165, 2024.
Article in English | MEDLINE | ID: mdl-39006323

ABSTRACT

Background and objectives: The study aimed to establish the efficiency of combining the Posiforlid heated eye mask with intense pulsed light therapy (IPL), as a treatment strategy for evaporative dry eye disease. Materials and methods: This study included 110 patients, respectively 220 eyes, diagnosed with evaporative dry eye disease, patients between 18 and 86 years old, divided into two study groups. The first one, the control group, consisted of 73 patients treated with IPL therapy, and the second of 37 patients, who underwent IPL therapy associated with Posiforlid heated eye mask. Subjective evolution was assessed using an eye fitness test (EFT) regarding symptomatology. Objective assessment of the ocular surface was performed by tear film stability evaluation (TFSE), non-invasive first break-up time (NIFBUT), non-invasive average breakup time (NIABUT), ocular surface inflammatory evaluation (OSIE), measuring of the central tear meniscus height (CTMH) and thinnest tear meniscus height (TTMH). The assessment was performed at the beginning of the IPL treatment, during the IPL sessions, at the end of the IPL treatment, and afterward, at 3, 6, and 12 months. Results: Tear film stability has increased in both study cases, but no statistically significant difference was observed between the two groups studied. For the control group, tear film stability evaluation (TFSE) started from 310.56 ± 389.54 at baseline (time 1 presentation) to 114.40 ± 122.90 after 12 months, and for the heated mask group, from 391.11 ± 456.45 (time 1 presentation) to 97.38 ± 105.98 after 12 months. NIABUT increased from 10.72 ± 4.90 seconds to 14.79 ± 3.72 seconds in the control group, and from 11.11 ± 5.08 seconds to 15.84 ± 2.26 seconds in the second group. OSIE decreased, as expected, from 7.18 ± 7.93 percent in the control group to 2.24 ± 2.38 percent after 12 months and from 7.42 ± 7.77 percent to 2.47 ± 2.50 percent in the Posiforlid group. Although significantly lower, there was no significant difference between the two studied groups. No statistically significant changes were registered in the studied quantitative parameters. Using the EFT test, great improvements were registered regarding symptomatology, with a score increasing from 29.99 ± 8.60 to 39.10 ± 5.08 in the control group and from 27.35 ± 9.24 to 38.35 ± 4.62 in the other group. Again, the same statistical result was registered on this variable. Conclusions: The improvement of tear film stability, ocular surface inflammatory condition, and subjective symptoms during IPL therapy sessions and the first year of observation after the completion of the treatment was not necessarily increased by the additional use of a heated eye mask. Abbreviations: IPL = intense pulsed light therapy, EFT = eye fitness test, NIFBUT = non-invasive first break-up time, NIABUT = non-invasive average break-up time, OSIE = ocular surface inflammatory evaluation, TFSE = tear film stability evaluation, CTMH = central tear meniscus height, TTMH = thinnest tear meniscus height, DED = dry eye disease, MGD = meibomian gland dysfunction, SD = standard deviation.


Subject(s)
Dry Eye Syndromes , Intense Pulsed Light Therapy , Tears , Humans , Dry Eye Syndromes/therapy , Dry Eye Syndromes/diagnosis , Dry Eye Syndromes/physiopathology , Female , Middle Aged , Male , Aged , Adult , Intense Pulsed Light Therapy/methods , Tears/metabolism , Treatment Outcome , Young Adult , Aged, 80 and over , Adolescent , Follow-Up Studies
2.
Vet Ophthalmol ; 2024 Jul 16.
Article in English | MEDLINE | ID: mdl-39013802

ABSTRACT

OBJECTIVE: To compare ocular surface parameters in dogs with different cephalic conformations and evaluate correlations among tests. ANIMALS STUDIED: Sixty-eight privately owned dogs. PROCEDURES: The study categorized canine eyes into three groups based on the craniofacial ratio (CFR): brachycephaly (≤0.52), mesocephaly (>0.52 to <0.67), and dolichocephaly (≥0.67). All eyes were examined using an ocular surface analyzer (OSA-VET) to determine lipid layer thickness (LLT) of the tear film, tear meniscus height (TMH), non-invasive tear breakup time (NIBUT), and meibomian gland loss rate of the lower eyelids (MGLRL). Schirmer tear test 1 (STT-1) and tear film breakup time (TBUT) were also performed. Statistical analyses involved one-way ANOVA, Kruskal-Wallis H test, post hoc Holm-Sidak test, and Pearson correlation coefficient. RESULTS: While STT-1 showed no significant difference among dog groups, brachycephalic dogs had significantly lower values in TBUT, NIBUT, and LLT, and a higher TMH, compared to mesocephalic and dolichocephalic dogs. Additionally, brachycephalic dogs exhibited a significantly higher MGLRL than dolichocephalic dogs. Correlations among tests were generally weak to moderate (r < .6) except for a strong correlation between CFR and LLT (r = .641, p < .001), and between TBUT and NIBUT (r = .899, p < .001). CONCLUSIONS: Brachycephalic morphology predisposes dogs to a significantly thinner lipid layer and diminished tear film stability, likely due to factors such as impaired meibomian gland function and increased ocular exposure compared to other cephalic conformations, thereby increasing their risk of keratoconjunctivitis sicca (KCS). OSA-VET shows a valuable tool to provide more comprehensive and precise diagnosis for canine ocular surface disorders.

3.
Ophthalmol Sci ; 4(5): 100546, 2024.
Article in English | MEDLINE | ID: mdl-39051043

ABSTRACT

Purpose: This study aims to develop and assess an infrastructure using Python-based deep learning code for future diagnostic and management purposes related to dry eye disease (DED) utilizing smartphone images. Design: Cross-sectional study using data which was gathered in Vision Health Research Clinic. Participants: One thousand twenty-one eye images from 734 patients were included in this article that categorizes into 70% females and 30% males, with no sex and age limit. Methods: One specialist captured eye images using Samsung A71 (601 images) and iPhone 11 (420 images) cell phones with the flashlight on and direct gaze to the camera. These images include the area of only 1 eye (left/right). Main Outcome Measures: First, our specialist did 3 different segmentations for every eye image separately for 80% of the training data. This part contains eye, lower eyelid, and iris segmentation. In 20% of test data after automated cropping of the lower eyelid margin and upscaling by 8×, the appropriate tear meniscus height segmentation will be chosen and measured using a deep learning algorithm. Results: The model was trained on 80% of the data and 20% of the data used for validation from both phones with different resolutions. The dice coefficient of the trained model for validation data is 98.68%, and the accuracy of the overall model is 95.39%. Conclusions: It appears that this algorithm holds the potential to herald an evolution in the future of diagnosis and management of DED by homecare devices solely through smartphones. Financial Disclosures: The author(s) have no proprietary or commercial interest in any materials discussed in this article.

4.
Eur J Ophthalmol ; : 11206721241266008, 2024 Jul 26.
Article in English | MEDLINE | ID: mdl-39056135

ABSTRACT

PURPOSE: Study the effect on the tear film in blepharospasm (BEB), facial hemispasm (FH), or aberrant regeneration (AR) treated with Botulinum Toxin (BTX-A). METHODS: A prospective study was used to evaluate the tear film in patients with BEB, FH, or AR treated with BTX-A. Schirmer tests, break-up time (BUT), optical coherence tomography (OCT) meniscus measurement, the Ocular Surface Disease Index (OSDI) questionnaire, and Oxford scale were documented before; 1 month after; and 3 months after BTX-A treatment. Comparisons were made with the Friedman test and Wilcoxon matched-pairs signed rank test was used. A p-value <0.05 was considered statistically significant. RESULTS: A total of 35 eyes from 27 patients were included. The mean patient age was 66.81 ± 12.94 years and 18 (66.7%) were female. Ten (37%) patients had BEB, six (22.2%) had FH, and 11 (40.74%) had AR. BTX-A improved the lid spasms. One month after BTX-A, Schirmer tests showed slight increments (Schirmer 1 p = 0.009; Schirmer 2 p = 0.05) and at 3 months they became similar to pre-treatment (p = 0.5). The BUT test was not significantly different at 1 month (p = 0.450) or at 3 months. On OCT 1 month after BTX-A, there was an increase in tear meniscus area (p = 0.004), height (p = 0.007), and depth (p = 0.004), and at 3 months the measurements also became similar to the pre-BTX-A values. No significant changes in the OSDI (p = 0.717) and Oxford scale (p = 0.255). CONCLUSION: OCT is a good tool to detect the increase in tear meniscus after periocular BTX-A in BEB, FH, and AR.

5.
BMC Ophthalmol ; 24(1): 241, 2024 Jun 10.
Article in English | MEDLINE | ID: mdl-38853245

ABSTRACT

BACKGROUND: To compare the effects of a 3D head-up system and microscope eyepiece-assisted simulated vitrectomy intraocular illumination on the ocular surface of an operator. METHODS: This was a prospective randomized controlled study. According to the application system, thirty ophthalmic operators (60 eyes) were randomly divided into 3D and eyepiece groups. Under different intensities of intraocular illumination, operators in both groups viewed the fundus model through a 3D display screen or microscopic eyepiece for 2 h. Objective examinations and a subjective symptom questionnaire were used immediately after the test to evaluate the ocular surface of the operators. Objective examinations included nonintrusion tear meniscus height (NIKTMH), nonintrusion break-up time (NIKBUT), and bulbar redness and strip meniscometry tube (SMTube) measurements. Statistical analyses were performed by using SPSS 26.0 software. RESULTS: After the test, the NIKTMH, NIKBUT and SMTube measurements decreased; however, the degree of change varied among the groups of different systems. The differences between the 3D group and the eyepiece group in NIKTMH measurements, SMTube measurements, subjective symptom scores (eye dryness, difficulty focusing, and cervical pain), and light intensity reaching the ocular surface of the operators were statistically significant (P < 0.05). All of the objective and subjective tests showed that the 3D group had fewer effects on the NIKTMH and SMTube measurements, and the subjective comfort of the 3D group was greater. CONCLUSION: For both 3D screens and eyepieces, simulated vitrectomy with intraocular illumination for two hours can lead to discomfort and abnormalities in the operator's ocular surface; however, these abnormalities are less severe in the 3D group. TRIAL REGISTRATION: This trial was registered on December 22, 2022, at the Chinese Clinical Trials Registry with NO. ChiCTR2200066989.


Subject(s)
Imaging, Three-Dimensional , Vitrectomy , Humans , Vitrectomy/methods , Vitrectomy/instrumentation , Prospective Studies , Male , Female , Adult , Lighting/instrumentation , Tears , Microscopy/methods , Dry Eye Syndromes
6.
Open Vet J ; 14(3): 846-851, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38682139

ABSTRACT

Background: Healthy vision in humans and animals requires a stable tear film. The environmental factor could affect the status of the tear film. Therefore, assessing the tear film in animals is essential to avoid visual system disturbance. Aim: The current research used a noninvasive device to evaluate the tear meniscus height (TMH) and lipid layer pattern (LLP) in domestic cats. In addition, the scores were compared with those of humans with healthy eyes. Methods: Fifty-four domestic cats (28 males and 26 females; mean ± SD = 13.9 ± 18.2 months) were randomly selected and included in the study. The cats were healthy, without any ocular disorders or diseases. Fifty-four healthy eye subjects (27 males and 27 females; mean ± SD = 25.6 ± 5.1 years) were randomly recruited and took part in the study for comparison. EASYTEAR View+ was used, for the first time, to assess the tear film parameters on the right eye of each subject. The examiner allowed a 5-minute gap between the tests. Each test was performed by the same examiner three times, followed by calculating the mean scores. Results: Significant differences (Mann-Whitney U test) were found in the median scores of LLP (p = 0.009) between cats and subjects with healthy eyes. The median TMH score was higher in cats (0.18 mm) than in humans (0.14). However, no significant difference (Mann-Whitney U Test, p = 0.210) exists in the TMH scores between cats and humans. The LLP analysis indicated that a dense white-blue lipid layer (grade 4 or D; lipid layer thickness, LLT, = approximately 80 nm) was predominant in both cats (N = 24, 44.4%) and humans (N = 29, 53.7%). In comparison, variable colors lipid layer (grade 5 or E; LLT = 90-140 nm) was a minority in cats (N = 5, 9.3%) and common in humans (N = 16, 29.6%). The statistical analysis indicated medium correlations between cats' TMH and LLP scores (r = 0.431, p < 0.01) and between age and TMH scores in humans (r = 0.440, p < 0.01). In addition, it indicated a weak correlation (r = 0.291, p < 0.05) between the LLP scores in cats and humans. Conclusion: Assessing animals' tear film is essential to avoid any ocular disorders. EASYTEAR View+ is efficiently used to evaluate domestic cats' TMH and LLP. Cats have thicker lipid layers and longer TMH comparable to those reported for humans with healthy eyes.


Subject(s)
Tears , Animals , Cats/physiology , Tears/physiology , Male , Female , Lipids/analysis , Humans
7.
Int J Ophthalmol ; 17(4): 659-664, 2024.
Article in English | MEDLINE | ID: mdl-38638253

ABSTRACT

AIM: To investigate the short-term effects of commercially available eyelid-cleaning wipes on film parameters. METHODS: This study enrolled 48 healthy participants aged 20-35y (both males and females). Clinical assessment included the Ocular Surface Disease Index (OSDI) questionnaire, non-invasive tear break-up time (NITBUT), tear meniscus height (TMH), and lipid layer pattern (LLP). Based on these initial results, participants were categorized as either non-dry eye or dry eye. Participants in each group were randomly allocated to either Blephaclean® or Systane® treatments. Changes in NITBUT, TMH, and LLP levels before and after lid wipe treatment were assessed. RESULTS: The dry eye group exhibited significantly higher OSDI scores and lower NITBUT and TMH levels than in the non-dry eye group (P<0.001). Following the application of eyelid wipes (Systane® wipes), dry eye subjects experienced a significant improvement in NITBUT levels (P=0.0014) compared to the non-dry eye individuals. Although the remaining participants showed a marginal increase in TMH and NITBUT levels, these changes did not achieve statistical significance (P>0.05). Similarly, the LLP levels were significantly improved with Systane® (P<0.001) post-treatment compared to individuals in the non-dry eye group. However, the dry eye subjects showed higher post-treatment LLP levels than the untreated group (P<0.02). CONCLUSION: The short-term effects of Systane® eyelid wipes on tear film parameters suggest their effectiveness in dry eye disease. Nonetheless, further exploration of their long-term impact is essential to justify their cost effectiveness and efficacy in treating both aqueous deficiency and evaporative dryness.

8.
Clin Exp Optom ; : 1-7, 2024 Apr 16.
Article in English | MEDLINE | ID: mdl-38627017

ABSTRACT

CLINICAL RELEVANCE: Tear meniscus height (TMH) is an important clinical marker in dry eye diagnosis and management. PURPOSE: To evaluate the reproducibility and agreement of TMH measurements in non-clinical participants using the Oculus Keratograph 5 M, Medmont Meridia, and Spectral-domain optical coherence tomography (Spectralis SD-OCT). METHODS: Fifty-six participants (mean 43.8 ± 22.4 years) were recruited for this cross-sectional study. Image acquisitions were performed on the three devices, sequentially and randomized. The repeatability and reproducibility of inter-observer and inter-device analysis were performed. Repeated measures ANOVA and Bland-Altman Plots were used to evaluate the agreement between devices. RESULTS: The mean TMH with the Oculus Keratograph 5 M, Medmont Meridia and Spectralis SD-OCT were 0.29 ± 0.16 mm, 0.24 ± 0.09 mm and 0.27 ± 0.16 mm, respectively. There were no significant inter-observer differences (paired t-tests, p < 0.001). All the devices exhibited good inter-observer reliability (ICC ≥ 0.877), and good repeatability (CV ≤ 16.53%). Inter-device reliability is moderate (ICC = 0.621, p < 0.001). Repeated measures ANOVA revealed that TMH measurements given by the Spectralis SD-OCT are not significantly different from the Oculus Keratograph 5 M (p = 0.19) and the Medmont Meridia (p = 0.38). TMH measurements from Oculus Keratograph 5 M were significantly higher than those from Medmont Meridia (p = 0.02). Correlations between the mean TMH and the difference in the TMH measurements were positive for Oculus Keratograph 5 M and Medmont Meridia (r2 = 0.62, p < 0.001), negative for Medmont Meridia and Spectralis SD-OCT (r2 = -0.59, p < 0.001), and not significant for Oculus Keratograph 5 M and Spectralis SD-OCT (r2 = 0.05, p = 0.74). A strong correlation was found for TMH measured with all devices (r2 = 0.55 to 0.81, p < 0.001). CONCLUSIONS: The Oculus Keratograph 5 M, Medmont Meridia, and Spectralis SD-OCT provide reliable and reproducible inter-observer TMH measurements. Inter-device reliability is moderate, with a close correlation between Spectralis SD-OCT and the Oculus Keratograph 5 M. Oculus Keratograph 5 M and Medmont Meridia are repeatable devices appropriate for the measurement of TMH, but they are not interchangeable in clinical practice.

9.
Int Ophthalmol ; 44(1): 193, 2024 Apr 24.
Article in English | MEDLINE | ID: mdl-38653918

ABSTRACT

PURPOSE: This study evaluated the tear film stability in patients with symptoms of dry eye after installation of dual polymer hydroxypropyl guar/sodium hyaluronate (DPHG/SH) vs single polymer SH. METHODS: Patients with recently diagnosed mild to moderate dry eye disease (OSDI score 23-32 points) were included. For each patient, the right eye was randomized to receive DPHG/SH or 0.15% SH. Just after the administration of the drop to the right eye, the fellow eye received the other eye drop. The first non-invasive Keratograph first break-up time (NIKBUT), average NIKBUT and tear meniscus height (TMH) were measured before administration of the eye drops, at 1-min, 15 min, 30 min, 60 min, 90 min, and 120 min after instillation. RESULTS: A total of 29 patients aged 22.8 ± 2.2 years participated in the study (21 women). No differences between the eye receiving DPHG/SH and single polymer SH were observed for the first NIKBUT (p = 0.45) and average NIKBUT (p = 0.24) variables at any time point. Both DPHG/SH and single polymer SH increased the TMH (p of time effect < 0.001), but with no difference between groups (p = 0.95). CONCLUSION: Both DPHG/SH and single polymer SH solutions provide lubrication of the eye surface, however, with no difference in NIKBUT and TMH evaluations for up to two hours following administration.


Subject(s)
Dry Eye Syndromes , Hyaluronic Acid , Ophthalmic Solutions , Tears , Humans , Dry Eye Syndromes/drug therapy , Dry Eye Syndromes/diagnosis , Female , Hyaluronic Acid/administration & dosage , Male , Ophthalmic Solutions/administration & dosage , Young Adult , Adult , Polysaccharides/administration & dosage , Polymers , Viscosupplements/administration & dosage , Prospective Studies
10.
Jpn J Ophthalmol ; 68(2): 139-145, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38499913

ABSTRACT

PURPOSE: To compare endonasal dacryocystorhinostomy (EN-DCR) with sheath-guided dacryoendoscopic probing and bicanalicular intubation (SG-BCI) by evaluating tear meniscus area (TMA) and total high-order aberrations (HOAs) for primary acquired nasolacrimal duct obstruction (PANDO). METHOD: We retrospectively reviewed 56 eyes of 42 patients (7 men, 35 women; age, 72.7±13.1 years) who underwent EN-DCR or SG-BCI for PANDO in Toyama University Hospital from February 2020 to June 2022. In the EN-DCR and SG-BCI groups, we measured the patency of the lacrimal passage, preoperative and postoperative TMA, and HOAs of the central 4 mm of the cornea using optical coherence tomography (AS-OCT), six months postoperatively. RESULTS: There was a positive correlation between preoperative TMA and preoperative HOAs in all cases. Postoperative patency of lacrimal passage was 100% in the EN-DCR and 80.8% in the SG-BCI group. There was a significant difference in the number of passages between the two groups (p = 0.01). Preoperative TMA and HOAs showed a significant postoperative decrease in both groups (EN-DCR group: p<0.01, p<0.01, SG-BCI group: p<0.01, p=0.03, respectively). We then calculated the rate of change of preoperative and postoperative TMA and HOAs and compared them between the two groups. The rate of change was significantly higher in the EN-DCR group than that in the SG-BCI group (TMA, p=0.03; HOAs, p=0.02). CONCLUSION: Although both EN-DCR and SG-BCI are effective for PANDO, our results suggest that EN-DCR is more effective in improving TMA and HOAs.


Subject(s)
Dacryocystorhinostomy , Lacrimal Duct Obstruction , Meniscus , Nasolacrimal Duct , Male , Humans , Female , Middle Aged , Aged , Aged, 80 and over , Lacrimal Duct Obstruction/diagnosis , Lacrimal Duct Obstruction/therapy , Nasolacrimal Duct/surgery , Retrospective Studies , Dacryocystorhinostomy/methods , Treatment Outcome
11.
Ophthalmic Physiol Opt ; 44(4): 704-717, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38546401

ABSTRACT

PURPOSE: To investigate differences in key clinical parameters between asymptomatic and highly symptomatic soft contact lens (CL) wearers after 14 h of wear. METHODS: In this pilot investigation, Phase 1 identified asymptomatic (CLDEQ-8 score ≤ 7) and highly symptomatic (CLDEQ-8 score ≥ 20) subjects after fitting with nelfilcon A CLs. Phase 2 investigated the following over a single nelfilcon A CL-wearing day (14 ± 2 h): blinking characteristics, tear meniscus height (TMH), non-invasive tear break-up time (NIBUT), tear film osmolarity and eyelid margin staining. Parameters for the two groups were compared using linear mixed models and post-hoc testing. The relationship between comfort scores and the clinical parameters was also investigated. RESULTS: Overall, 161 and 42 subjects were enrolled into Phase 1 and 2, respectively. Twenty-five asymptomatic and 17 symptomatic subjects completed Phase 2. Lower eyelid TMH was decreased after 14 h in symptomatic compared with asymptomatic subjects (least square mean [LSM] difference -0.04 mm, 95% CI: -0.07, -0.01). Osmolarity was lower in symptomatic than in asymptomatic subjects at fitting (LSM difference -9.89, 95% CI: -18.91, -0.86). Upper eyelid margin staining was greater after 14 h in symptomatic than in asymptomatic subjects (LSM difference 0.53, 95% CI: 0.01, 1.05) and greater after 14 h than baseline in the symptomatic group (LSM difference 0.61, 95% CI: 0.16, 1.07). There was a significant relationship between comfort and upper eyelid margin staining (r = -0.40, 95% CI: -0.63, -0.11) and blink rate (r = -0.31, 95% CI: -0.57, -0.003). CONCLUSION: The potential parameters most effective in differentiating asymptomatic from symptomatic wearers were upper eyelid margin staining and lower TMH. The parameter with the strongest relationship to comfort was upper eyelid margin staining, where higher comfort scores were associated with lower levels of staining.


Subject(s)
Blinking , Contact Lenses, Hydrophilic , Tears , Humans , Contact Lenses, Hydrophilic/adverse effects , Male , Female , Adult , Tears/metabolism , Tears/physiology , Pilot Projects , Blinking/physiology , Young Adult , Osmolar Concentration , Dry Eye Syndromes/diagnosis , Dry Eye Syndromes/etiology , Dry Eye Syndromes/physiopathology , Eyelids
12.
Int Ophthalmol ; 44(1): 14, 2024 Feb 06.
Article in English | MEDLINE | ID: mdl-38321290

ABSTRACT

PURPOSE: To evaluate the association of tear meniscus height (TMH) with clinical outcomes of patients who underwent endonasal dacryocystorhinostomy. METHODS: We recruited 304 patients from two institutes. The TMH was measured using anterior segment optical coherence tomography before surgery. All patients underwent endoscopic DCR with lacrimal intubation stent insertion. The lacrimal stent was removed 2 months after surgery. The TMH was measured at 2 months and 12 months after surgery. Improvements in epiphora were assessed using a visual analogue scale (range, 0-2). Recurrence was determined based on lacrimal irrigation and endoscopic evaluation results. RESULTS: All patients experienced improvements in subjective symptoms 2 months after surgery. The mean TMH also decreased significantly compared with that before surgery. During the follow-up period, four patients experienced recurrence. The mean TMH 12 months after surgery was significantly lower than that before surgery. The rate of change in the TMH was significantly associated with the use of a dacryoendoscope during sheath-guided lacrimal stent intubation at all time points. Of the 251 patients who were followed up at 12 months after surgery, three reported recurrences, and 17 reported mild improvement of epiphora. The rate of change in the TMH was significantly associated with epiphora improvement. Height was also associated with epiphora improvement. CONCLUSIONS: Endoscopic DCR is an acceptable surgical procedure for managing nasolacrimal duct obstruction. Sheath-guided lacrimal stent intubation using a dacryoendoscope resulted in a greater reduction in postoperative TMH compared to the blind insertion technique, which may lead to favorable clinical outcomes.


Subject(s)
Dacryocystorhinostomy , Lacrimal Duct Obstruction , Meniscus , Nasolacrimal Duct , Humans , Dacryocystorhinostomy/methods , Nasolacrimal Duct/surgery , Endoscopy/methods , Treatment Outcome
13.
Int Ophthalmol ; 44(1): 105, 2024 Feb 21.
Article in English | MEDLINE | ID: mdl-38378968

ABSTRACT

PURPOSE: This study aims to investigate the effects of external dacryocystorhinostomy (DCR) surgery on tear meniscus parameters and assess its relationship with improvements in quality of life (QoL) in patients with nasolacrimal duct obstruction (NLDO). METHODS: This prospective study included 30 patients diagnosed with NLDO who underwent external DCR surgery. Tear meniscus (TM) parameters, including height, depth and area, were measured using anterior segment optical coherence tomography. Lacrimal symptom questionnaire (LacQ), Munk scores and Glasgow benefit inventories (GBI) were collected. Statistical analysis was performed to evaluate the correlation between tear meniscus changes and improvements in QoL. RESULTS: TM height, depth and area decreased from preoperative median measurements (0.09 mm2, 0.37 mm, 0.56 mm) to postoperative median measurements (0.03 mm2, 0.21 mm, 0.30 mm) (p < 0.001). Lacrimal symptom scores and Munk scores showed a significant improvement at 3-month postoperatively (p < 0.001). The GBI scores also demonstrated a significant improvement, indicating a positive impact on the patients' QoL. (p < 0.001). A statistically significant correlation was found between the change in TM parameters and LacQ lacrimal symptom scores. CONCLUSION: External DCR surgery leads to significant improvements in tear meniscus parameters and quality of life outcomes in patients with NLDO. The decreased in TM height and TM area indicates improved tear film dynamics and decreased tear volume, which positively impact the patients' ocular comfort and overall well-being. This study highlights the importance of tear meniscus evaluation as a potential market for assessing the success of DCR surgery and its impact on patients' QoL.


Subject(s)
Dacryocystorhinostomy , Lacrimal Duct Obstruction , Meniscus , Nasolacrimal Duct , Humans , Dacryocystorhinostomy/methods , Lacrimal Duct Obstruction/diagnosis , Quality of Life , Nasolacrimal Duct/surgery , Prospective Studies
14.
J Clin Med ; 13(3)2024 Jan 23.
Article in English | MEDLINE | ID: mdl-38337353

ABSTRACT

(1) Background: Dry eye disease (DED) is a chronic ocular surface condition that requires precise diagnostic tools. The present study aimed to investigate the diagnostic potential of the absolute inter-eye difference (|OD-OS|) in tear meniscus height (TMH) for the detection of the presence of aqueous deficient dry eye (ADDE). (2) Methods: A sample of 260 participants with dry eye complaints underwent ocular surface examinations thorough diagnostic assessments based on the Tear Film and Ocular Surface Society guidelines (TFOS DEWS II). Participants were subsequently categorized as No ADDE and ADDE based on TMH. Statistical analyses to determine the optimal TMH|OD-OS| cut-off value in a randomly selected study group (200 participants) were performed, while a separate validation analysis of the cut-off value obtained in a random cross-validation group (60 participants) was also performed. (3) Results: The significant diagnostic capability of TMH|OD-OS| (area under the curve = 0.719 ± 0.036, p < 0.001) was found. The identified cut-off value of 0.033 mm demonstrated reliable specificity (77.6%) and moderate sensitivity (59.1%). Cross-validation confirmed the cut-off value's association with the TFOS DEWS II diagnostic criterion (Cramer's V = 0.354, p = 0.006). (4) Conclusions: The present study provides evidence for the diagnostic potential of TMH|OD-OS| in identifying ADDE. The identified cut-off value enhances the specificity and offers moderate sensitivity, providing an objective tool for clinical decision making.

15.
Diagnostics (Basel) ; 14(3)2024 Feb 01.
Article in English | MEDLINE | ID: mdl-38337832

ABSTRACT

PURPOSE: We aimed to evaluate the feasibility of using a novel device, the Smart Eye Camera (SEC), for assessing tear meniscus height (TMH) after fluorescein staining and the agreement of the results with measurements obtained using standard slit lamp examination. METHODS: TMH was assessed using both SEC and conventional slit lamp examination. The images were analyzed using the software ImageJ 1.53t (National Institutes of Health, Bethesda, MD, USA). A common measurement unit scale was established based on a paper strip, which was used as a calibration marker to convert pixels into metric scale. A color threshold was applied using uniform parameters for brightness, saturation, and hue. The images were then binarized to black and white to enhance the representation of the tear menisci. A 2 mm area around the upper and lower meniscus in the central eye lid zone was selected and magnified 3200 times to facilitate manual measurement. The values obtained using SEC were compared with those obtained with a slit lamp. RESULTS: The upper and lower TMH values measured using the SEC were not statistically different from those obtained with a slit lamp (0.209 ± 0.073 mm vs. 0.235 ± 0.085, p = 0.073, and 0.297 ± 0.168 vs. 0.260 ± 0.173, p = 0.275, respectively). The results of Bland-Altman analysis demonstrated strong agreement between the two instruments, with a mean bias of -0.016 mm (agreement limits: -0.117 to 0.145 mm) for upper TMH and 0.031 mm (agreement limits: -0.306 to 0.368 mm) for lower TMH. CONCLUSIONS: The SEC demonstrated sufficient validity and reliability for assessing TMH in healthy eyes in a clinical setting, demonstrating concordance with the conventional slit lamp examination.

16.
Vet Ophthalmol ; 27(3): 214-227, 2024 May.
Article in English | MEDLINE | ID: mdl-38140703

ABSTRACT

OBJECTIVES: The objective of the study was to evaluate whether a twice-daily instillation of 0.45% preservative-free ketorolac tromethamine (FKT) or 0.4% benzalkonium chloride-preserved ketorolac tromethamine (BACKT), every 12 h for 30 days may affect tear film parameters and the meibography in healthy dogs. Additionally, we assessed whether the same treatments irritated the ocular surface, affected goblet cell density (GCD), and the levels of oxidative stress biomarkers (OSB) in the conjunctiva of the same dogs. PROCEDURES: Experimental and masked comparison study. In 11 healthy dogs baseline values of the lipid layer thickness, tear meniscus height, non-invasive tear breakup time (NI-TFBT), and the meibomian gland (MG) loss were assessed by OSAvet®. For each dog, one eye received 40 µL of BACKT, while the other received 40 µL FKT, every 12 h for 30 consecutive days. Tear parameters and meibography were repeated 15, 30, and 60 days post-treatments. Conjunctival hyperemia and blepharospasm were monitored at the same time points. At baseline and Day 30, a conjunctival biopsy was collected for GCD and OSB determination. RESULTS: Conjunctival hyperemia and blepharospasm were not observed. At Day 15, the MG loss increased only in FKT-treated eyes (p < .001). On Day 30, both treatment groups showed increased MG loss, shortened NI-TFBT, and reduced GCD and catalase (p < .05). At Day 30, BACKT-treated eyes showed lower levels of superoxide dismutase (SOD) (p = .006) and higher levels of malondialdehyde (MDA) (p = .02). Differences between treatments were not observed for any parameter at any time point (p > .05). 60 days after treatment, OSAvet® parameters tended to return to values assessed at baseline; however, significant differences remained for MG loss (p < .05). CONCLUSIONS: Twice-daily instillation of KT, containing or not BAC, for 30 consecutive days shortened NI-TFBT, decreased GCD, and increased the MG loss in healthy dogs. KT should be used with caution when prescribed for long periods, particularly in patients with tear film abnormalities. However, future controlled studies using KT, BAC, and other topical NSAIDs are indicated to further support this finding.


Subject(s)
Conjunctiva , Goblet Cells , Ketorolac Tromethamine , Oxidative Stress , Tears , Animals , Dogs , Oxidative Stress/drug effects , Goblet Cells/drug effects , Tears/drug effects , Conjunctiva/drug effects , Female , Male , Ketorolac Tromethamine/administration & dosage , Ketorolac Tromethamine/pharmacology , Anti-Inflammatory Agents, Non-Steroidal/administration & dosage , Anti-Inflammatory Agents, Non-Steroidal/pharmacology , Meibomian Glands/drug effects , Meibomian Glands/metabolism , Ophthalmic Solutions
17.
Vet Med Sci ; 10(1): e1334, 2024 01.
Article in English | MEDLINE | ID: mdl-38100149

ABSTRACT

OBJECTIVE: The tear clearance rate (TCR), determined using anterior segment optical coherence tomography (AS-OCT) images, and its correlation with ocular surface parameters, including blink rate, Schirmer tear test-1 (STT-1) and tear film breakup time (TFBUT), were evaluated. ANIMALS STUDIED: Left eyes of 20 client-owned dogs with no ocular disease symptoms. PROCEDURES: The tear meniscus height (TMH) was evaluated using AS-OCT images before the instillation of 5 µL saline (TMHbase ), immediately post-instillation (TMH0 ), 30-s post-instillation (TMH0.5 ) and at 1 min intervals for 5 min post-instillation (TMH1 , TMH2 , TMH3 , TMH4 and TMH5 ). The TCR was calculated using the formula [(TMH0  - TMH0.5 )/TMH0 ]×100 (%). The eyes were classified into two groups with the median: 'High TMHbase ' (n = 10) and 'Low TMHbase ' (n = 10). Eyes with STT-1 values ≥15 mm/min and TFBUT ≥ 12 s were assigned to the 'Satisfied' subgroup, whereas eyes not satisfying these criteria were assigned to the 'Not satisfied' subgroup. RESULTS: TMH0 was higher than TMH0.5 (p = 0.02), wherein TMH0.5 to TMH5 did not differ significantly. The TCR and blink rate were negatively correlated (p = 0.02). The 'Not satisfied' subgroup in the low TMHbase group had a lower TCR (p = 0.02) and higher blink rate (p = 0.04) than the 'Satisfied' subgroup. CONCLUSIONS: TCR can be evaluated using AS-OCT in dogs. Eyes with a lower TCR blink more frequently. TMH merits studying to understand ocular surface health.


Subject(s)
Dog Diseases , Dry Eye Syndromes , Humans , Dogs , Animals , Tomography, Optical Coherence/veterinary , Tomography, Optical Coherence/methods , Dry Eye Syndromes/diagnosis , Dry Eye Syndromes/veterinary , Tears , Receptors, Antigen, T-Cell
18.
Diagnostics (Basel) ; 13(24)2023 Dec 12.
Article in English | MEDLINE | ID: mdl-38132226

ABSTRACT

The pre-lens tear film (PLTF) over (i) delefilcon A silicone hydrogel water gradient (WG; 33-80% from core to surface) contact lenses (CLs) (SHWG-CLs) and (ii) subjects' own non-WG soft CLs (SCLs) (SO-SCLs) was studied in 30 eyes of 30 subjects to assess the hypothesized PLTF stabilization over SHWG-CLs. In both eyes, delefilcon A SHWG-CLs (DAILIES TOTAL1®; Alcon, Fort Worth, TX, USA) or SO-SCLs were worn. After 15 min of wearing each lens, the tear meniscus radius (TMR, mm), lipid-layer interference grade (IG) and spread grade (SG), and non-invasive breakup time (NIBUT, seconds) were evaluated and compared between the SHWG-CLs and the SO-SCLs. The comparison between the SHWG-CL and SO-SCL groups (SHWG-CL and SO-SCL, mean ± SD) revealed that TMRs temporarily decreased and reached a plateau value after 15 min (0.21 ± 0.06; 0.21 ± 0.06) compared to the value prior to CL insertion (0.24 ± 0.08; 0.25 ± 0.08), with no significant difference between the two groups. The NIBUT, IG, and SG values after 15 min of wearing the CLs were (9.7 ± 3.7; 4.7 ± 4.2), (1.0 ± 0.2; 1.8 ± 1.0), and (1.1 ± 0.4; 1.9 ± 1.5), respectively, and all values were significantly better in the SHWG-CL group (p < 0.0001, p = 0.0039, and p < 0.0001, respectively). We found that compared to the SO-SCLs, the maintenance of the PLTF on the SHWG-CLs was supported by the thicker and more stable PLTF.

19.
Int J Ophthalmol ; 16(12): 1911-1918, 2023.
Article in English | MEDLINE | ID: mdl-38111923

ABSTRACT

AIM: To investigate the relationship between dynamic tear meniscus parameters and dry eye using an automated tear meniscus segmentation method. METHODS: The analysis of tear meniscus videos captured within 5s after a complete blink includes data from 38 participates. By processing video data, several key parameters including the average height of the tear meniscus at different lengths, the curvature of the tear meniscus's upper boundary, and the total area of the tear meniscus in each frame were calculated. The effective values of these dynamic parameters were then linearly fitted to explore the relationship between their changing trends and dry eye disease. RESULTS: In 94.74% of the samples, the average height of central tear meniscus increased over time. Moreover, 97.37% of the samples exhibited an increase in the overall tear meniscus height (TMH) and area from the nasal to temporal side. Notably, the central TMH increased at a faster rate compared to the nasal side with the temporal side showing the slowest ascent. Statistical analysis indicates that the upper boundary curvature of the whole tear meniscus as well as the tear meniscus of the nasal side (2, 3, and 4 mm) aid in identifying the presence of dry eye and assessing its severity. CONCLUSION: This study contributes to the understanding of tear meniscus dynamics as potential markers for dry eye, utilizing an automated and non-invasive approach that has implications for clinical assessment.

20.
Clin Case Rep ; 11(11): e8175, 2023 Nov.
Article in English | MEDLINE | ID: mdl-38028090

ABSTRACT

Key Clinical Message: Asymptomatic lacrimal canaliculus stones causing many stones without symptoms are rare. The patient recovered well within a week after dacryolith removal. This diagnosis is prevalent in this age group. However, asymptomatic nasolacrimal obstruction should be considered. Abstract: Dacryoliths, also known as symptomatic stones, are frequently observed in the lacrimal drainage system. These stones manifest through symptoms such as conjunctivitis, discharge, and epiphora. Nevertheless, the occurrence of numerous stones in the lacrimal canaliculus, in the absence of apparent symptoms, is uncommon. In this study, we present a case with the presence of several stones within the inferior lacrimal canaliculus. A female patient, aged 74, appeared with bilateral senile cataracts and was scheduled for cataract surgery. During a standard ocular examination, it was observed that the tear meniscus height in the left eye had a greater magnitude compared with the right eye. Canaliculitis with dacryolith was verified using a series of diagnostic procedures, including physical inspection, fluorescent dye disappearance test, palpation, 50 Mhz ultrasound biomicroscope scan, and irrigation of the lacrimal canaliculi. Upon surgical investigation, the canaliculus obstruction was confirmed, characterized by the existence of many tiny dacryolith formations inside the inferior canalicular system. Following the surgical excision of the dacryoliths, the patient experienced a full remission within a week. While it is common for individuals in this age range to receive this diagnosis, it is important to consider silent nasolacrimal blockage as a potential alternative diagnosis. It is important to note that the presence of dacryoliths in the lacrimal drainage system might manifest independently of conjunctivitis. No discernible risk indicators were found in relation to the aforementioned patient.

SELECTION OF CITATIONS
SEARCH DETAIL
...