Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 758
Filter
1.
J Cardiovasc Imaging ; 32(1): 2, 2024 Jun 12.
Article in English | MEDLINE | ID: mdl-38907302

ABSTRACT

BACKGROUND: Mitral annulus (MA) area is derived during transthoracic echocardiography (TTE) assuming of a circular shape using the MA diameter from the apical 4 chamber (A4c) view. Since the MA is not a circular structure, we hypothesized that an elliptical model using parasternal long-axis (PLAX) and apical 2 chamber (A2c) view measured MA diameters would have better agreement with 3-dimensional transesophageal echocardiography (3D TEE) measured MA in degenerative mitral valve disease (DMVD). METHODS: Seventy-six patients with moderate-to-severe DMVD had 2D TTE and 3D TEE performed. MA area was measured retrospectively using semi-automatic modeling of 3D data (3D TEEsa) and considered as the reference method. MA diameters were measured using different 2D TTE views. MA area was calculated using assumptions of a circular or an elliptical shape. 2D TTE derived and 3D TEEsa. MA areas were compared using linear regression and Bland-Altman analysis. RESULTS: The median MA area measured at 3D TEEsa was 1,386 (1,293-1,673) mm2. With 2D TTE, the circular model using A4c view diameter resulted in a small systematic underestimation of MA area (6%), while the elliptical model using PLAX and A2c diameters resulted in 25% systematic underestimation. The standard deviations of the distributions of inter-method differences were wide for all 2D TTE methods (265-289 mm2) when compared to 3D TEEsa, indicating imprecision. CONCLUSIONS: When compared with 3D TEEsa modeling of the MA as the reference, the assumption of a circular shape using A4c TTE view diameter was the method with the least systematic error to assess MA area in DMVD and moderate to severe regurgitation.

2.
Article in English | MEDLINE | ID: mdl-38890085

ABSTRACT

This article is the eighth in an annual series reviewing the research highlights of the year pertaining to the subspecialty of perioperative echocardiography for the Journal of Cardiothoracic and Vascular Anesthesia. The authors thank the editor-in-chief, Dr Kaplan, and the editorial board for the opportunity to continue this series. In most cases, these will be research articles targeted at the perioperative echocardiographic diagnosis and treatment of patients after cardiothoracic surgery; but in some cases, the articles will target the use of perioperative echocardiography in general.

3.
Echocardiography ; 41(6): e15861, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38853674

ABSTRACT

BACKGROUND: Transesophageal echocardiography (TEE) is primarily used to guide transcatheter structural heart interventions, such as tricuspid transcatheter edge-to-edge repair (TEER). Although TEE has a good safety profile, it is still an invasive imaging technique that may be associated with complications, especially when performed during long transcatheter procedures or on frail patients. The aim of this study was to assess TEE-related complications during tricuspid TEER. METHODS: This is a prospective study enrolling 53 patients who underwent tricuspid TEER for severe tricuspid regurgitation (TR). TEE-related complications were assessed clinically and divided into major (life-threatening, major bleeding requiring transfusions or surgery, organ perforation, and persistent dysphagia) and minor (perioral hypesthesia, < 24 h dysphagia/odynophagia, minor intraoral bleeding and hematemesis not requiring transfusion) RESULTS: The median age of the patient population was 79 years; 43.4% had severe, 39.6% massive, and 17.6% torrential TR. 62.3% of patients suffered from upper gastrointestinal disorders. Acute procedural success (APS) was achieved in 88.7% in a median device time of 36 min. A negative association was shown between APS and lead-induced etiology (r = -.284, p = .040), baseline TR grade (r = -.410, p = .002), suboptimal TEE view (r = -.349, p = .012), device time (r = -.234, p = .043), and leaflet detachment (r = -.496, p < .0001). We did not observe any clinical manifest major or minor TEE-related complications during the hospitalization. CONCLUSIONS: Our study reinforces the good safety profile and efficacy of TEE guidance during tricuspid TEER. Adequate preoperative management and intraprocedural precautions are mandatory in order to avoid serious complications. Furthermore, suboptimal intraprocedural TEE views are associated with lower TR reduction rates. HIGHLIGHTS: Transesophageal echocardiography is a crucial and safe technique for guiding transcatheter structural heart interventions. A mix of mid/deep esophageal and trans gastric views, as well as real-time 3D imaging is generally used to guide the procedure. Adequate preoperative management and intraprocedural precautions are mandatory in order to avoid serious problems. A shorter device time is associated with more rarely probe-related complications. Suboptimal intraprocedural TEE views are associated with lower TR reduction rates.


Subject(s)
Echocardiography, Transesophageal , Tricuspid Valve Insufficiency , Tricuspid Valve , Humans , Echocardiography, Transesophageal/methods , Female , Male , Prospective Studies , Tricuspid Valve Insufficiency/surgery , Aged , Tricuspid Valve/diagnostic imaging , Tricuspid Valve/surgery , Cardiac Catheterization/methods , Cardiac Catheterization/adverse effects , Treatment Outcome , Aged, 80 and over
4.
Ann Pediatr Cardiol ; 17(1): 67-69, 2024.
Article in English | MEDLINE | ID: mdl-38933054

ABSTRACT

We describe a unique report of percutaneous closure of multiple secundum atrial septal defects in a child utilizing three Occlutech Figulla septal occluders deployed sequentially. The procedure was performed under live three-dimensional transesophageal echocardiography guidance.

5.
Front Med ; 2024 May 18.
Article in English | MEDLINE | ID: mdl-38761357

ABSTRACT

Current guidelines encourage large studies in a diverse population to establish normal reference ranges for three-dimensional (3D) echocardiography for different ethnic groups. This study was designed to establish the normal values of 3D-left ventricular (LV) and left atrial (LA) volume and function in a nationwide, population-based cohort of healthy Han Chinese adults. A total of 1117 healthy volunteers aged 18-89 years were enrolled from 28 collaborating laboratories in China. Two sets of 3D echocardiographic instruments were used, and full-volume echocardiographic images were recorded and transmitted to a core laboratory for image analysis with a vendor-independent off-line workstation. Finally, 866 volunteers (mean age of 48.4 years, 402 men) were qualified for final analysis. Most parameters exhibited substantial differences between different sex and age groups, even after indexation by body surface area. The normal ranges of 3D-LV and 3D-LA volume and function differed from those recommended by the American Society of Echocardiography and the European Association of Cardiovascular Imaging guidelines, presented by the World Alliance Societies of Echocardiography (WASE) study, and from the 2D values in the EMINCA study. The normal reference values of 3D echocardiography-derived LV and LA volume and function were established for the first time in healthy Han Chinese adults. Normal ranges of 3D-LV and 3D-LA echocardiographic measurements stratified with sex, age, and race should be recommended for clinical applications.

6.
J Clin Ultrasound ; 2024 May 28.
Article in English | MEDLINE | ID: mdl-38804714

ABSTRACT

BACKGROUND: Recent studies have shown that right atrial (RA) function are important predictors of cardiovascular morbidity and mortality. However, the study data about RA phasic function in obstructive sleep apnea syndrome (OSAS) patients are scarce, especially based on the left ventricular geometry. So, we aimed to assess the influence of left ventricular geometry on RA phasic function in OSAS patients via a multimodal echocardiographic approach. METHODS: Total of 235 OSAS patients were enrolled in this cross-section study and underwent complete clinical, polysomnography, and echocardiography examinations. The OSAS patients were divided into four groups based on left ventricular mass index (LVMI) and relative wall thickness (RWT): normal geometry (NG), concentric remodeling (CR), concentric hypertrophy (CH), and eccentric hypertrophy (EH). RA phasic function was evaluated via multimodal echocardiography approach (two-dimensional echocardiography biplane method [2DE]; two-dimensional speckle-tracking echocardiography [2D-STE]; and three-dimensional echocardiography [3DE]). The multiple linear regression analysis was used to determine the relationship between left ventricular geometry and RA phasic function. RESULTS: The RA volume and indices increased from NG to CR to EH to CH. RA total emptying fraction and RA strain during systole decreased from NG to CR to EH to CH. RA passive emptying fraction and RA strain during early diastole similarly decreased. RA active emptying fraction and RA strain during late diastole also gradually increased similarly. In analyses that adjusted for gender, age, body mass index, systolic blood pressure, apnea-hypopnea index, LVMI, systolic pulmonary artery pressure, and right ventricular free wall thickness, CH was associated with RA reservoir and conduit function via 2DE area-length method, whereas CH and EH were associated with RA reservoir and conduit function via 2D-STE and 3DE method. Further, CH was associated with RA booster pump function via 2DE area-length method, 2D-STE, and 3DE method. CONCLUSION: The RA volumes and phasic function varied with left ventricular geometry via multimodal echocardiography approach. CH had the apparent negative effect on RA phasic function.

7.
Article in English | MEDLINE | ID: mdl-38754748

ABSTRACT

BACKGROUND: The accuracy of right ventricular (RV) quantification by three-dimensional echocardiography (3DE) has been reported mainly in patients with a normal right ventricle (RV). However, there are no data regarding the accuracy of 3DE in patients with a dilated RV, as in shunt diseases. In this study, we evaluated the accuracy of 3DE and that of volumetric (Vol) cardiac magnetic resonance (CMR) for assessment of RV and left ventricular (LV) stroke volume (SV) and the pulmonary (Qp)/systemic (Qs) blood flow ratio in patients with an atrial septal defect (ASD) using the two-dimensional phase contrast (2DPC) method as the gold standard. METHODS: We retrospectively investigated 83 patients with ASD who underwent transcatheter closure and clinically indicated CMR and 3DE examinations. The ratio Qp/Qs was calculated using RV and LV SV measured by full-volume volumetric 3DE (Vol-3DE) and CMR (Vol-CMR) and by two-dimensional pulsed Doppler quantification (2D-Dop); the parameters were compared using 2DPC-CMR as the gold standard. RESULTS: There was no significant difference in the Qp/Qs value between 2DPC-CMR and Vol-3DE (2.29 ± 0.70 vs 2.21 ± 0.63, P = .79) and 2D-Dop (vs 2.21 ± 0.65, P = 1.00); however, a significant difference was found between 2DPC-CMR and Vol-CMR (P < .001). The Qp/Qs value obtained using Vol-3DE showed the best correlation with 2DPC-CMR (r = 0.93, P < .001). The RV and LV SV values obtained by Vol-3DE showed the best correlation with 2DPC-CMR (RV SV, r = 0.82, P < .001; LV SV, r = 0.73, P < .001), although the absolute values were underestimated. CONCLUSION: Qp/Qs was more accurately evaluated by Vol-3DE than by Vol-CMR or 2D-Dop. Three-dimensional echocardiography assessment was feasible and reproducible even in a dilated RV.

8.
Cardiooncology ; 10(1): 24, 2024 Apr 15.
Article in English | MEDLINE | ID: mdl-38616279

ABSTRACT

BACKGROUND: Anthracyclines can cause left ventricular (LV) dysfunction. There is little data about right ventricular (RV) damage during chemotherapy. AIM: This study aimed to investigate the toxic effects of chemotherapy, analyzing its impact on right ventricular function. MATERIAL AND METHODS: A prospective study was conducted, enrolling 83 female patients (55 ± 11 years old) affected by breast cancer treated with anthracyclines. Cardiological evaluation, HFA risk score assessment and comprehensive echocardiogram, including speckle tracking analysis and 3D analysis, were performed before starting chemotherapy (T0) and at 3 (T1), 6 (T2) and 12 months (T3) after beginning treatment. RV function was assessed with tricuspid annular plane excursion (TAPSE), S' wave of the tricuspid annulus, fractional area change (FAC), RV global longitudinal strain (RV-GLS), free wall strain (RV-FWLS) and RV 3D ejection fraction (RV-3DEF). Subclinical LV CTRCD was defined as a reduction of GLS > 15% compared to baseline. Subclinical RV cardiotoxicity was defined as the co-presence of a relative decrease of 10% from baseline in RV-3DEF and a relative reduction of 15% from baseline RV-FWLS. RESULTS: After chemotherapy, we found a significant reduction in 2D-LVEF (p = < 0.001) and 3D-LVEF (p = < 0.001), in LV-GLS and RVLS (p = < 0.001), in FAC and TAPSE, also RV-3DEF reduced significantly (p = 0.002). 39% of patients developed LV subclinical CTRCD; 28% of patients developed RV subclinical cardiotoxicity. LV and RV changes occurred concomitantly, and no RV echocardiographic parameters were found to predict the development of LV CTRCD and vice-versa. CONCLUSION: After anthracyclines-based chemotherapy, LV and RV subclinical damage occurs, and it can be detected early by speckle-tracking and 3D echocardiography.

9.
J Clin Med ; 13(5)2024 Feb 28.
Article in English | MEDLINE | ID: mdl-38592247

ABSTRACT

(1) Introduction and Aims: Right ventricular (RV) remodeling significantly impacts the prognosis of dilated cardiomyopathy (DCM) patients, and right atrial (RA) size and function are still often neglected in DCM patients. Accordingly, our aims were to (i) evaluate right heart subclinical changes and (ii) the prognostic value of RA compared to left atrial (LA) size and function in patients with DCM by advanced echocardiography. (2) Materials and Methods: Sixty-eight patients with DCM (with a mean age of 60 years; 35 men) were evaluated by comprehensive transthoracic echocardiography, compared to 62 age- and sex-matched healthy controls (with a mean age of 61 years; 32 men), and followed up for 12.4 ± 5 months. (3) Results: DCM patients have RV and RA global longitudinal dysfunction by 2DSTE, higher RA minimum volumes and tricuspid annulus areas despite having normal RV volumes, ejection fractions, and RA maximum volumes by 3DE compared to the controls. The RA strain and RV strain are correlated with each other. The RA reservoir strain (with an AUC = 0.769) has an increased value for outcome prediction compared to that of the LA strain. (4) Conclusion: Patients with DCM have RV longitudinal dysfunction and decreased RA function, in the absence of clinical RV involvement or atrial arrhythmias, and the RA strain is associated with an increased risk of hospitalization and cardiac death.

11.
Echocardiography ; 41(5): e15823, 2024 May.
Article in English | MEDLINE | ID: mdl-38678585

ABSTRACT

The morphologic features of the multiple atrial septal defects assessed by TTE-based 3D imaging were similar to those by 3D-TEE. TTE-based 3D model had excellent visibility, allowing observation of 3D structure of the rims of the defects. It may be useful method for assessment of the multiple atrial septal defects.


Subject(s)
Echocardiography, Three-Dimensional , Heart Septal Defects, Atrial , Vena Cava, Inferior , Humans , Heart Septal Defects, Atrial/diagnostic imaging , Echocardiography, Three-Dimensional/methods , Vena Cava, Inferior/diagnostic imaging , Female , Male , Adult
12.
Front Cardiovasc Med ; 11: 1301116, 2024.
Article in English | MEDLINE | ID: mdl-38650919

ABSTRACT

Advances in pediatric cardiac surgery have resulted in a recent growing epidemic of children and young adults with congenital heart diseases (CHDs). In these patients, congenital defects themselves, surgical operations and remaining lesions may alter cardiac anatomy and impact the mechanical performance of both ventricles. Cardiac function significantly influences outcomes in CHDs, necessitating regular patient follow-up to detect clinical changes and relevant risk factors. Echocardiography remains the primary imaging method for CHDs, but clinicians must understand patients' unique anatomies as different CHDs exhibit distinct anatomical characteristics affecting cardiac mechanics. Additionally, the use of myocardial deformation imaging and 3D echocardiography has gained popularity for enhanced assessment of cardiac function and anatomy. This paper discusses the role of echocardiography in evaluating cardiac mechanics in most significant CHDs, particularly its ability to accommodate and interpret the inherent anatomical substrate in these conditions.

13.
Echocardiography ; 41(3): e15802, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38527007

ABSTRACT

The right sinus of the Valsalva aneurysm (SVA) rupturing into the right atrium (RA) and dissecting into the interventricular septum (IVS) is rare. The disease can be definitively diagnosed using two-dimensional (2D) echocardiography and color Doppler ultrasonography. Real-time biplane imaging and three-dimensional (3D) echocardiography offer new perspectives for viewing and diagnosing this disease.


Subject(s)
Aneurysm, Ruptured , Aortic Aneurysm , Aortic Dissection , Aortic Rupture , Sinus of Valsalva , Ventricular Septum , Humans , Aortic Aneurysm/complications , Aortic Aneurysm/diagnostic imaging , Sinus of Valsalva/diagnostic imaging , Heart Atria/diagnostic imaging
14.
J Am Soc Echocardiogr ; 37(6): 634-640, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38467312

ABSTRACT

Accurate knowledge of right ventricular (RV) volumes and ejection fraction is fundamental to providing optimal care for pediatric patients with congenital and acquired heart disease, as well as pulmonary hypertension. Traditionally, these volumes have been measured using cardiac magnetic resonance because of its accuracy, reproducibility, and freedom from geometric assumptions. More recently, an increasing number of studies have described the measurement of RV volumes using three-dimensional (3D) echocardiography. In addition, volumes by 3D echocardiography have also been used for outcome research studies in congenital heart surgery. Importantly, 3D echocardiographic acquisitions can be obtained over a small number of cardiac cycles, do not require general anesthesia, and are less costly than CMR. The ease and safety of the 3D echocardiographic acquisitions allow serial studies in the same patient. Moreover, the studies can be performed in various locations, including the intensive care unit, catheterization laboratory, and general clinic. Because of these advantages, 3D echocardiography is ideal for serial evaluation of the same patient. Despite these potential advantages, 3D echocardiography has not become a standard practice in children with congenital and acquired heart conditions. In this report, the authors review the literature on the feasibility, reproducibility, and accuracy of 3D echocardiography in pediatric patients. In addition, the authors investigate the advantages and limitations of 3D echocardiography in RV quantification and offer a pathway for its potential to become a standard practice in the assessment, planning, and follow-up of congenital and acquired heart disease.


Subject(s)
Echocardiography, Three-Dimensional , Humans , Echocardiography, Three-Dimensional/methods , Child , Heart Ventricles/diagnostic imaging , Heart Ventricles/physiopathology , Reproducibility of Results , Ventricular Dysfunction, Right/diagnostic imaging , Ventricular Dysfunction, Right/physiopathology , Stroke Volume/physiology , Heart Defects, Congenital/diagnostic imaging , Heart Defects, Congenital/physiopathology , Child, Preschool , Infant , Sensitivity and Specificity , Heart Diseases/diagnostic imaging , Heart Diseases/physiopathology , Heart Diseases/diagnosis
15.
BMC Med Imaging ; 24(1): 61, 2024 Mar 13.
Article in English | MEDLINE | ID: mdl-38481130

ABSTRACT

OBJECTIVE: The paper aimed to improve the accuracy limitations of traditional two-dimensional ultrasound and surgical procedures in the diagnosis and management of congenital heart disease (chd), and to improve the diagnostic and therapeutic level of chd. METHOD: This article first collected patient data through real-time imaging and body surface probes, and then diagnosed 150 patients using three-dimensional echocardiography. In order to verify the effectiveness of the combination therapy, 60 confirmed patients were divided into a control group and an experimental group. The control group received conventional two-dimensional ultrasound and surgical treatment, while the experimental group received three-dimensional ultrasound and image guided surgical treatment. RESULT: In the second diagnosis, the diagnostic accuracy of type 1, type 2, and type 3 in the control group was 84.21%, 84.02%, and 83.38%, respectively. The diagnostic accuracy rates of type 1, type 2, and type 3 in the experimental group were 92.73%, 92.82%, and 92.83%, respectively. In the control group, 2 males and 1 female experienced heart failure after surgery. However, in the experimental group, 0 males and 0 females experienced heart failure after surgery. CONCLUSION: The combination of three-dimensional echocardiography and image guided surgery can improve diagnostic accuracy and surgical treatment effectiveness, thereby reducing risks and complications, and improving surgical success rate.


Subject(s)
Echocardiography, Three-Dimensional , Heart Defects, Congenital , Heart Failure , Surgery, Computer-Assisted , Male , Humans , Female , Heart Defects, Congenital/diagnostic imaging , Heart Defects, Congenital/surgery , Echocardiography, Three-Dimensional/methods , Ultrasonography
16.
Int J Cardiovasc Imaging ; 40(5): 1105-1114, 2024 May.
Article in English | MEDLINE | ID: mdl-38507153

ABSTRACT

We aimed to evaluate clinical and prognostic significance of myocardial work parameters of the systemic right ventricle (SRV). Thirty-eight patients with the SRV underwent echocardiographic assessment of the SRV systolic function including 3D-echocardiography derived ejection fraction, 2D longitudinal strain and myocardial work analysis. The study endpoint was the combination of all-cause mortality and heart transplantation. Global constructive work (GCW) and global work index (GWI) demonstrated moderate correlation with the 3DE-derived SRV ejection fraction (EF) (Rho 0.64, p < 0.0001 and Rho 0.63, p < 0.0001, respectively). GCW showed the strongest correlation with the BNP level (Rho - 0.77, p < 0.0001), closely followed by GWI, 4-chamber longitudinal strain and 3DE EF (all Rho - 0.73, p < 0.0001). GCW and GWI were significantly lower in patients with moderate or severe tricuspid regurgitation compared with less than moderate regurgitation (1226 ± 439 vs 1509 ± 264 mmHg%, p = 0.02, and 984 ± 348 vs 1259 ± 278 mmHg%, p = 0.01, respectively). During a follow-up of 3.5 (2.8-3.9) years, seven patients (18%) died and one received transplantation (3%). They had significantly lower GCW and GWI compared with patients who did not reach the study endpoint (908 ± 255 vs 1433 ± %, p < 0.001 and 721 ± 210 vs 1173 ± 315 mmHg%, p < 0.001, respectively). In Cox regression analysis, GCW, GWI, 3DE SRV volumes and EF were the best-fit models based on the Akaike Information Criterion, outperforming longitudinal strain parameters. GWI and GCW, novel echocardiographic parameters of myocardial work, provided reliable quantification of the SRV systolic function. GWI, GCW and 3DE-derived SRV parameters were closely associated with all-cause mortality and heart transplantation in patients with the SRV.


Subject(s)
Echocardiography, Three-Dimensional , Heart Transplantation , Predictive Value of Tests , Stroke Volume , Ventricular Function, Right , Humans , Male , Female , Middle Aged , Time Factors , Risk Factors , Adult , Prognosis , Ventricular Dysfunction, Right/physiopathology , Ventricular Dysfunction, Right/diagnostic imaging , Ventricular Dysfunction, Right/etiology , Ventricular Dysfunction, Right/mortality , Aged , Myocardial Contraction , Tricuspid Valve Insufficiency/physiopathology , Tricuspid Valve Insufficiency/diagnostic imaging , Tricuspid Valve Insufficiency/surgery , Tricuspid Valve Insufficiency/mortality , Severity of Illness Index , Heart Ventricles/diagnostic imaging , Heart Ventricles/physiopathology , Retrospective Studies
17.
Biomedicines ; 12(2)2024 Jan 28.
Article in English | MEDLINE | ID: mdl-38397904

ABSTRACT

Atrioventricular coupling has recently emerged as an outcome predictor. Our aim was to assess, through three-dimensional (3D) echocardiography, the role of the left atrioventricular coupling index (LACI), right atrioventricular coupling index (RACI) and a novel combined atrioventricular coupling index (CACI) in a cohort of patients with dilated cardiomyopathy (DCM). One hundred twenty-one consecutive patients with DCM underwent comprehensive 3D echocardiographic acquisitions. LACI was defined as the ratio between left atrial and left ventricular 3D end-diastolic volumes. RACI was defined as the ratio between right atrial and right ventricular 3D end-diastolic volumes. CACI was defined as the sum of LACI and RACI. Patients were prospectively followed for death, heart transplant, nonfatal cardiac arrest and hospitalization for heart failure. Fifty-five patients reached the endpoint. All three coupling indices were significantly more impaired in patients with events, with CACI showing the highest area under the curve (AUC = 0.66, p = 0.003). All three indices were independent outcome predictors when tested in multivariable Cox regression (HR = 2.62, p = 0.01 for LACI; HR = 2.58, p = 0.004 for RACI; HR = 2.37, p = 0.01 for CACI), but only CACI showed an incremental prognostic power over traditional risk factors such as age, left ventricular strain, right ventricular strain and mitral regurgitation severity (likelihood ratio χ2 test = 28.2, p = 0.03). CACI assessed through 3D echocardiography, reflecting both left and right atrioventricular coupling, is an independent predictor of adverse events in DCM, yielding an incremental prognostic power over traditional risk factors.

18.
Arch Cardiovasc Dis ; 117(2): 134-142, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38290892

ABSTRACT

BACKGROUND: Left atrial (LA) strain is a simple marker of LA function. The aim of the study was to evaluate the determinants of atrial cardiomyopathy in AF. METHODS: In this pilot study, we prospectively evaluated clinical, biological, metabolomic and echocardiographic parameters for 85 consecutive patients hospitalized for atrial fibrillation (AF) with restoration of sinus rhythm at 6 months. Eighty-one patients with an analysable LA strain at 6 months were divided into groups according to median reservoir strain:<23.3% (n=40) versus≥23.3% (n=41). RESULTS: Compared to patients with the highest LA strain, patients with lowest LA strain had multiple differences at admission: clinical (older age; more frequent history of AF; more patterns of persistent AF); biological (higher fasting blood glucose levels, glycated haemoglobin, high-sensitivity C-reactive protein, and urea; lower glomerular filtration rate); metabolomic (higher levels of kynurenine, kynurenine/tryptophan, and urea/creatinine; lower levels of arginine and methionine/methionine sulfoxide); and echocardiographic (higher two-dimensional end-systolic LA volume [LAV] indexes; higher three-dimensional end-systolic and end-diastolic LAV and right atrial volume indexes; lower LA and right atrial emptying fractions and three-dimensional right ventricular ejection fraction) (all P<0.05). Area under the receiver operating characteristic curve to predict LA strain alteration at 6 months was highest for a combined score including clinical, biological, metabolomic and echocardiographic variables at admission (area under the receiver operating characteristic curve 0.871; P<0.0001). CONCLUSIONS: LA reservoir strain could be a memory of initial atrial myocardial stress in AF. It can be predicted using a combination of clinical, biological, metabolomic and echocardiographic admission variables.


Subject(s)
Atrial Fibrillation , Humans , Atrial Fibrillation/diagnostic imaging , Stroke Volume , Kynurenine , Pilot Projects , Ventricular Function, Right , Heart Atria/diagnostic imaging , Urea
19.
J Am Soc Echocardiogr ; 37(2): 259-267, 2024 Feb.
Article in English | MEDLINE | ID: mdl-37995938

ABSTRACT

BACKGROUND: The dynamic shape of the normal adult mitral annulus has been shown to be important to mitral valve function. However, annular dynamics of the healthy mitral valve in children have yet to be explored. The aim of this study was to model and quantify the shape and major modes of variation of pediatric mitral valve annuli in four phases of the cardiac cycle using transthoracic echocardiography. METHODS: The mitral valve annuli of 100 children and young adults with normal findings on three-dimensional echocardiography were modeled in four different cardiac phases using the SlicerHeart extension for 3D Slicer. Annular metrics were quantified using SlicerHeart, and optimal normalization to body surface area was explored. Mean annular shapes and the principal components of variation were computed using custom code implemented in a new SlicerHeart module (Annulus Shape Analyzer). Shape was regressed over metrics of age and body surface area, and mean shapes for five age-stratified groups were generated. RESULTS: The ratio of annular height to commissural width of the mitral valve ("saddle shape") changed significantly throughout age for systolic phases (P < .001) but within a narrow range (median range, 0.20-0.25). Annular metrics changed statistically significantly between the diastolic and systolic phases of the cardiac cycle. Visually, the annular shape was maintained with respect to age and body surface area. Principal-component analysis revealed that the pediatric mitral annulus varies primarily in size (mode 1), ratio of annular height to commissural width (mode 2), and sphericity (mode 3). CONCLUSIONS: The saddle-shaped mitral annulus is maintained throughout childhood but varies significantly throughout the cardiac cycle. The major modes of variation in the pediatric mitral annulus are due to size, ratio of annular height to commissural width, and sphericity. The generation of age- and size-specific mitral annular shapes may inform the development of appropriately scaled absorbable or expandable mitral annuloplasty rings for children.


Subject(s)
Echocardiography, Three-Dimensional , Heart Valve Prosthesis , Mitral Valve Insufficiency , Young Adult , Humans , Child , Mitral Valve/surgery , Echocardiography , Echocardiography, Three-Dimensional/methods
20.
Echocardiography ; 41(1): e15717, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37990989

ABSTRACT

OBJECTIVES: Right ventricular (RV)-pulmonary arterial (PA) coupling is important in various cardiac diseases. Recently, several echocardiographic surrogates for RV-PA coupling have been proposed and reported to be useful in predicting outcomes. However, it remains unclear which surrogate is the most clinically relevant. This study aimed to comprehensively compare the prognostic value of different echocardiographic RV-PA coupling surrogates. METHODS: We retrospectively reviewed 242 patients with various cardiac conditions who underwent comprehensive transthoracic echocardiography with three-dimensional RV data. In addition to conventional parameters including tricuspid annular plane systolic excursion (TAPSE), fractional area change (FAC), and PA systolic pressure (PASP), we analyzed RV free wall and global longitudinal strain (FWLS and GLS). We also obtained RV ejection fraction (RVEF), stroke volume (SV), and end-systolic volume (ESV) using three-dimensional RV analysis. RV-PA coupling surrogates were calculated as TAPSE/PASP, FAC/PASP, FWLS/PASP, GLS/PASP, RVEF/PASP, and SV/ESV. The study endpoint was a composite outcome of all-cause death or cardiovascular hospitalization within 1 year. RESULTS: In multivariable analysis, all the RV-PA coupling surrogates were independent predictors of the outcome. Among the surrogates, the model with TAPSE/PASP showed the lowest prognostic value in model fit and discrimination ability, whereas the model with RVEF/PASP exhibited the highest prognostic value. The partial likelihood ratio test indicated that the model with RVEF/PASP was significantly better than the model with TAPSE/PASP (p < .024). CONCLUSION: All the RV-PA coupling surrogates were independent predictors of the outcome. Notably, RVEF/PASP had the highest prognostic value among the surrogates.


Subject(s)
Echocardiography, Three-Dimensional , Hypertension, Pulmonary , Ventricular Dysfunction, Right , Humans , Prognosis , Retrospective Studies , Echocardiography , Echocardiography, Three-Dimensional/methods , Stroke Volume , Ventricular Function, Right
SELECTION OF CITATIONS
SEARCH DETAIL
...