Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 2.800
Filter
1.
Aging (Albany NY) ; 162024 Jun 29.
Article in English | MEDLINE | ID: mdl-38950328

ABSTRACT

The current study aims to develop a new technique for the precise identification of Escherichia coli strains, utilizing matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) combined with a long short-term memory (LSTM) neural network. A total of 48 Escherichia coli strains were isolated and cultured on tryptic soy agar medium for 24 hours for the generation of MALDI-TOF MS spectra. Eight hundred MALDI-TOF MS spectra were obtained per strain, resulting in a database of 38,400 spectra. Fifty percent of the data was utilized for LSTM neural network training, with fine-tuned parameters for strain-level identification. The other half served as the test set to assess model performance. Traditional PCA dimension reduction of MALDI-TOF MS spectra indicated 47 out of 48 strains to be unclassifiable. In contrast, the LSTM neural network demonstrated remarkable efficacy. After 20 training epochs, the model achieved a loss value of 0.0524, an accuracy of 0.999, a precision of 0.985, and a recall of 0.982. When tested on the unseen data, the model attained an overall accuracy of 92.24%. The integration of MALDI-TOF MS and LSTM neural network markedly enhances the identification of Escherichia coli strains. This innovative approach offers an effective and accurate tool for MALDI-TOF MS-based strain-level identification, thus expanding the analytical capabilities of microbial diagnostics.

2.
Se Pu ; 42(7): 711-720, 2024 Jul.
Article in Chinese | MEDLINE | ID: mdl-38966979

ABSTRACT

Protein citrullination is an irreversible post-translational modification process regulated by peptidylarginine deiminases (PADs) in the presence of Ca2+. This process is closely related to the occurrence and development of autoimmune diseases, cancers, neurological disorders, cardiovascular and cerebrovascular diseases, and other major diseases. The analysis of protein citrullination by biomass spectrometry confronts great challenges owing to its low abundance, lack of affinity tags, small mass-to-charge ratio change, and susceptibility to isotopic and deamidation interferences. The methods commonly used to study the protein citrullination mainly involve the chemical derivatization of the urea group of the guanine side chain of the peptide to increase the mass-to-charge ratio difference of the citrullinated peptide. Affinity-enriched labels are then introduced to effectively improve the sensitivity and accuracy of protein citrullination by mass spectrometry. 2,3-Butanedione or phenylglyoxal compounds are often used as derivatization reagents to increase the mass-to-charge ratio difference of the citrullinated peptide, and the resulting derivatives have been observed to contain α-dicarbonyl structures. To date, however, no relevant studies on the reactivity of dicarbonyl compounds with citrullinated peptides have been reported. In this study, we determined whether six α-dicarbonyl and two ß-dicarbonyl compounds undergo derivatization reactions with standard citrullinated peptides using matrix-assisted laser desorption ionization-time-of-flight mass spectrometry (MALDI-TOF MS). Among the α-dicarbonyl compounds, 2,3-butanedione and glyoxal reacted efficiently with several standard citrullinated peptides, but yielded a series of by-products. Phenylglyoxal, methylglyoxal, 1,2-cyclohexanedione, and 1,10-phenanthroline-5,6-dione also derivated efficiently with standard citrullinated peptides, generating a single derivative. Thus, a new derivatization method that could yield a single derivative was identified. Among the ß-dicarbonyl compounds, 1,3-cyclohexanedione and 2,4-pentanedione successfully reacted with the standard citrullinated peptides, and generated a single derivative. However, their reaction efficiency was very low, indicating that the ß-dicarbonyl compounds are unsuitable for the chemical derivatization of citrullinated peptides. The above results indicate that the α-dicarbonyl structure is necessary for realizing the efficient and specific chemical derivatization of citrullinated peptides. Moreover, the side chains of the α-dicarbonyl structure determine the structure of the derivatives, derivatization efficiency, and generation (or otherwise) of by-products. Therefore, the specific enrichment and precise identification of citrullinated peptides can be achieved by synthesizing α-dicarbonyl structured compounds containing affinity tags. The proposed method enables the identification of citrullinated proteins and their modified sites by MS, thereby providing a better understanding of the distribution of citrullinated proteins in different tissues. The findings will be beneficial for studies on the mechanism of action of citrullinated proteins in a variety of diseases.


Subject(s)
Citrullination , Peptides , Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization , Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization/methods , Peptides/chemistry
3.
Heliyon ; 10(11): e32115, 2024 Jun 15.
Article in English | MEDLINE | ID: mdl-38947468

ABSTRACT

Background and aims: Through a nested cohort study, we evaluated the diagnostic performance of breath-omics in differentiating between benign and malignant breast lesions, and assessed the diagnostic performance of a multi-omics approach that combines breath-omics, ultrasound radiomics, and clinic-omics in distinguishing between benign and malignant breast lesions. Materials and methods: We recruited 1,723 consecutive patients who underwent an automated breast volume scanner (ABVS) examination. Breath samples were collected and analyzed by high-pressure photon ionization time-of-flight mass spectrometry (HPPI-TOF-MS) to obtain breath-omics features. 238 of 1,723 enrolled participants have received pathological confirmation of breast nodules finally. The breast lesions of the 238 participants were contoured manually based on ABVS images for ultrasound radiomics feature calculation. Then, single- and multi-omics models were constructed and evaluated for breast nodules diagnosis via five-fold cross-validation. Results: The area under the curve (AUC) of the breath-omics model was 0.855. In comparison, the multi-omics model demonstrated superior diagnostic performance for breast cancer, with sensitivity, specificity, and AUC of 84.1 %, 89.9 %, and 0.946, respectively. The multi-omics performance was comparable to that of the Breast Imaging Reporting and Data System (BI-RADS) classification via senior ultrasound physician evaluation. Conclusion: The multi-omics approach combining metabolites in exhaled breath, ultrasound imaging, and basic clinical information exhibits superior diagnostic performance and promises to be a non-invasive and reliable tool for breast cancer diagnosis.

4.
Article in English | MEDLINE | ID: mdl-38943376

ABSTRACT

Most melanomas progress from radial to vertical growth phase before spreading locoregionally and distally. Much is still unknown about the metabolic changes in the tumor cells and their microenvironment during this metastatic progression. We aimed to gain new insight into the molecular characteristics of melanoma in regard to spatial lipidomics to deliver new knowledge regarding tumor metastatic progression. We included 10 fresh tumor samples from 10 patients including two in situ melanomas, two invasive primary melanomas, and six metastatic melanomas (four in-transit metastases and two distant metastases). In addition, we analyzed four healthy skin controls from the same patients. Time-of-flight imaging secondary ion mass spectrometry (ToF-SIMS) enabled detailed spatial-lipidomics that could be directly correlated with conventional histopathological analysis of consecutive H&E-stained tissue sections. Significant differences in the lipid profiles were found in primary compared to metastatic melanomas, notably an increase in phosphatidylethanolamine lipids relative to phosphatidylinositol lipids and an increase in GM3 gangliosides in the metastatic samples. Furthermore, analysis of the data from in transit versus distant metastases samples highlighted that specific phospholipids, and a difference in the long versus shorter chain GM3 gangliosides, discriminated the metastatic routes. Further studies are warranted to verify these preliminary findings. Lipidomic changes could serve as a novel biomarker for tumor progression and even serve as a target for novel treatments. Furthermore, analyzing the lipid profiles could help to differentiate between primary and metastatic melanomas in challenging cases.

5.
Eur J Med Genet ; 69: 104950, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38830573

ABSTRACT

Newborn screening (NBS) for congenital adrenal hyperplasia (CAH) based on hormonal testing is successfully implemented in many countries. However, this method cannot detect non-classic CAH and has high false positive rates. We have developed a novel MALDI-TOF MS assay that can identify common variants and deletions of CYP21A2 in the Chinese population. Thirty-seven clinical patients with CAH confirmed by Sanger sequencing and MLPA analysis were detected by MALDI-TOF MS assay. Two CYP21A2 variants were detected in 30 patients and one CYP21A2 variant was detected in 7 patients. The MALDI-TOF MS assay detected 67 mutant alleles in 37 patients with a detection rate of 90.5%. Sanger sequencing revealed that three variants in seven patients were not included in the designed panel. Eleven distinct CYP21A2 variants were identified, including five missense variants, two nonsense variants, two large gene deletions, one splice variant, and one frameshift variant. The most frequent variant was c.293-13C > G (37.84%), followed by c.518T > A (21.62%) and exon 1-7 deletion (17.57%). The high-throughput MALDI-TOF MS assay that can simultaneously detect common variants and deletions of CYP21A2. This assay can be used for population-based genetic screening and rapid detection of suspected patients, and is expected to be a valuable complement to biochemical-based testing for the detection of CAH.


Subject(s)
Adrenal Hyperplasia, Congenital , Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization , Steroid 21-Hydroxylase , Humans , Steroid 21-Hydroxylase/genetics , Adrenal Hyperplasia, Congenital/genetics , Adrenal Hyperplasia, Congenital/diagnosis , Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization/methods , Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization/standards , Female , Male , Infant, Newborn , Neonatal Screening/methods , Infant , Genetic Testing/methods , Genetic Testing/standards , Gene Deletion
6.
J Mass Spectrom ; 59(7): e5066, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38888354

ABSTRACT

Structural change of ions induced by collision with a neutral has been studied in a guided ion beam tandem mass spectrometer, using Time-Of-Flight measurements and SIMION simulation. The exothermic catalytic isomerization of HOC+ to HCO+ is used to explore the new methodology. Isomerization is catalyzed via a proton transport mechanism through the interplay of a neutral molecule, the catalyst. Four different potential catalysts, Ne, D2, CH4, and C18O, were studied at different collision energies. SIMION simulation of the ion path and collision in the instrument leads to the highlight of a specific signature related to the catalytic isomerization in the time-of-flight spectra. This signature is used to identify the experimental conditions where isomerization takes place. Only C18O, at low collision energies, gives a clear signature of catalytic isomerization, and a quantitative estimate of the catalyzed isomerization cross-section and rate constant is derived. This new methodology is sensitive to clear presence of catalyzed isomerization and can be used in instruments designed for cross-section measurements, provided low collision energy is used and ion bunching is available.

7.
Food Chem X ; 22: 101509, 2024 Jun 30.
Article in English | MEDLINE | ID: mdl-38883916

ABSTRACT

In this study, muscle exudates from five fishes belonging to the family Sciaenidae, in the order Perciformes, were analyzed as models for the discovery of biomarkers by matrix-assisted laser desorption/ionization-time of flight mass spectrometry (MALDI-TOF MS). MagSi-weak cation exchange magnetic beads (WCX-MBs) were utilized for the enrichment of proteins from fish exudate samples, allowing protein biomarkers to be identified and subsequently used for fish species differentiation. Buffers with pH ranging from 4.0 to 9.0 can provide an environment for proteins in fish muscle exudate to bind to the WCX-MBs. The optimal enrichment based on WCX-MBs can be achieved when the exudate samples are diluted 100folds. More species-specific biomarkers in mass spectra can be identified when using WCX-MBs. The number of ions that can be considered as peak markers and can differentiate the analyzed fishes increases from 38 to 121 when using WCX-MBs to isolate peptides/protein in fish muscle exudate. Particularly, eight peak markers in mass spectra were assigned to be specific to Nibea albiflora (NA), three peak markers specific to Larimichthys crocea (LC), two peak markers specific to Miichthys miiuy (MM), seven peak markers specific to Collichthys lucidus (CL), and six peak markers specific to Larimichthys polyactis (LP). Furthermore, five proteins were identified based on the characterization of tryptic peptides and their potential to be biomarkers, of which four proteins specific to CL and one specific to LC were identified. The single-blind samples analysis demonstrated that these species-specific peak markers and protein biomarkers can be successfully utilized for corresponding fish recognition. The utilization of WCX-MBs can improve the discovery of fish species-specific biomarkers in fish muscle exudate samples. The present protocol holds potential of being a rapid and accurate identification tool for recognition of fish species.

8.
Sensors (Basel) ; 24(11)2024 May 25.
Article in English | MEDLINE | ID: mdl-38894194

ABSTRACT

Measuring temperature inside chemical reactors is crucial to ensuring process control and safety. However, conventional methods face a number of limitations, such as the invasiveness and the restricted dynamic range. This paper presents a novel approach using ultrasound transducers to enable accurate temperature measurements. Our experiments, conducted within a temperature range of 28.8 to 83.8 °C, reveal a minimal temperature accuracy of 98.6% within the critical zone spanning between 70.5 and 75 °C, and an accuracy of over 99% outside this critical zone. The experiments focused on a homogeneous environment of distilled water within a stainless-steel tank. This approach will be extended in a future research in order to diversify the experimental media and non-uniform environments, while promising broader applications in chemical process monitoring and control.

9.
Sensors (Basel) ; 24(11)2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38894370

ABSTRACT

Bulk wave acoustic time-of-flight (ToF) measurements in pipes and closed containers can be hindered by guided waves with similar arrival times propagating in the container wall, especially when a low excitation frequency is used to mitigate sound attenuation from the material. Convolutional neural networks (CNNs) have emerged as a new paradigm for obtaining accurate ToF in non-destructive evaluation (NDE) and have been demonstrated for such complicated conditions. However, the generalizability of ToF-CNNs has not been investigated. In this work, we analyze the generalizability of the ToF-CNN for broader applications, given limited training data. We first investigate the CNN performance with respect to training dataset size and different training data and test data parameters (container dimensions and material properties). Furthermore, we perform a series of tests to understand the distribution of data parameters that need to be incorporated in training for enhanced model generalizability. This is investigated by training the model on a set of small- and large-container datasets regardless of the test data. We observe that the quantity of data partitioned for training must be of a good representation of the entire sets and sufficient to span through the input space. The result of the network also shows that the learning model with the training data on small containers delivers a sufficiently stable result on different feature interactions compared to the learning model with the training data on large containers. To check the robustness of the model, we tested the trained model to predict the ToF of different sound speed mediums, which shows excellent accuracy. Furthermore, to mimic real experimental scenarios, data are augmented by adding noise. We envision that the proposed approach will extend the applications of CNNs for ToF prediction in a broader range.

10.
J Chromatogr A ; 1730: 465093, 2024 Jun 14.
Article in English | MEDLINE | ID: mdl-38897109

ABSTRACT

Herein, two "orthogonal" characteristics of moisture damaged cacao beans (temporally dependent molding kinetics versus the time-independent geographical region of origin) are simultaneously analyzed in a comprehensive two-dimensional (2D) gas chromatography time-of-flight mass spectrometry (GC×GC-TOFMS) dataset using tile-based Fisher ratio (F-ratio) analysis. Cacao beans from six geographical regions were analyzed once a day for six days following the initiation of moisture damage to trigger the molding process. Thus, there are two "extremes" to the experimental sample class design: six time points for the molding kinetics versus the six geographical regions of origin, resulting in a 6 × 6 element signal array referred to as a composite chemical fingerprint (CCF) for each analyte. Usually, this study would involve initial generation of two separate hit lists using F-ratio analysis, one hit list from inputting the data with the six time point classes, then another hit list from inputting the dataset from the perspective of geographic region of origin. However, analysis of two separate hit lists with the intent to distill them down to one hit list is extremely time-consuming and fraught with shortcomings due to the challenges associated with attempting to match analytes across two hit lists. To address this challenge, tile-based F-ratio analysis is "orthogonally applied" to each analyte CCF to simultaneously determine two F-ratios at the chromatographic 2D location (F-ratiokinetic and F-ratioregion) for each hit, by ranking a single hit list using the higher of the two F-ratios resulting in the discovery of 591 analytes. Further, using a pseudo-null distribution approach, at the 99.9% threshold over 400 analytes were deemed suitable for PCA classification. Using a more stringent 99.999% threshold, over 100 analytes were explored more deeply using PARAFAC to provide a purified mass spectrum.

11.
Mass Spectrom (Tokyo) ; 13(1): A0146, 2024.
Article in English | MEDLINE | ID: mdl-38887471

ABSTRACT

The areoles and spines of cacti can be used to desorb ions of ionic liquids (ILs) by the mere action of an electric field into the atmospheric pressure (AP) interface of a mass spectrometer. The small cactus species Opuntia microdasys bears numerous very fine hairs on its areoles and tiny sharp spines that appeared suited to serve as needle electrodes sharp enough for field desorption of ions to occur. In fact, positive and negative ions of four ILs could be desorbed by a process analogous to AP field desorption (APFD). In contrast to APFD where activated field emitters are employed, the ILs were deposited onto one or two adjacent areoles by applying 1-3 µL of a dilute solution in methanol. After evaporation of the solvent, the cactus was positioned next to the spray shield electrode of a trapped ion mobility-quadrupole-time-of-flight instrument. Desorption of IL cations and IL anions, respectively, did occur as soon as the electrode was set to potentials in the order of ±4.5 kV, while the cactus at ground potential was manually positioned in front of the entrance electrode to bring the areole covered with a film of the sample into the right position. Neither did mixing of ILs occur between neighboring areoles nor did the cactus suffer any damage upon its use as a botanical field emitter.

12.
Talanta ; 278: 126448, 2024 Jun 18.
Article in English | MEDLINE | ID: mdl-38905962

ABSTRACT

The analysis of pesticide residues and mycotoxins in baby food demands exceptionally low limits of quantitation, necessitating the use of highly sensitive instruments capable of conducting trace analyses. High-resolution instruments typically fail to detect such low levels. However, the latest advancements in liquid time-of-flight technology, when coupled with ion trapping, enable ion enrichment, thereby improving detection levels. This allows for the analysis of these substances at low concentration levels, benefiting from enhanced mass accuracy. Additionally, the use of mass accuracy data helped eliminate matrix interferences, thereby enabling high-confidence identification. We developed a multi-residue method to analyse 219 pesticide residues and 9 mycotoxin residues in baby food matrices. Utilizing a QuEChERS-based extraction method, the samples were then analysed using an LC-Zeno® trap QTOF with mass window screening acquisition. For pesticides, the limit of quantitation was 0.001-0.003 mg/kg for 81 % of the evaluated compounds, 0.005 mg/kg for 13 %, 0.010 mg/kg for 4 % and 0.020-0.030 for 2 %; good linearities were obtained at these levels. Apparent recoveries were evaluated at 0.003, 0.005, and 0.010 mg/kg. At the lowest recovery level, 93 % of compounds showed recoveries between 70 and 120 %. The rest of the compounds were in the range of 63-129 %, with relative standard deviation values below 20 %. For mycotoxins, the limits of quantitation ranged from 0.0001 to 0.100 mg/kg, with matrix-matched concentrations assessed within this range. Recoveries were evaluated at low concentration range (0.001-0.003 mg/kg) and high range (0.020-0.050) with apparent recoveries values between 92 and 140 %. Finally, a total of 31 commercial baby food samples were analysed using this method. The results indicated that 16 samples contained pesticide residues, while two samples were found to have mycotoxins.

13.
Se Pu ; 42(6): 564-571, 2024 Jun.
Article in Chinese | MEDLINE | ID: mdl-38845517

ABSTRACT

Protein phosphorylation plays an important role in cellular signaling and disease development. Advances in mass spectrometry-based proteomics have enabled qualitative and quantitative phosphorylation studies as well as in-depth biological explorations for biomarker discovery and signaling pathway analysis. However, the dynamic changes that occur during phosphorylation and the low abundance of target analytes render direct analysis difficult because mass spectral detection offers no selectivity, unlike immunoassays such as Western blot and enzyme-linked immunosorbent assay (ELISA). The present study aimed to solve one of the key problems in the specific and efficient isolation of phosphorylated peptides. A method based on a magnetic carbon nitride composite coupled with matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS) was developed for the enrichment and analysis of phosphopeptides with low abundance in complex samples. Magnetic carbon nitride composite was synthesized and characterized by electron microscopy, infrared spectroscopy, and X-ray diffractometry. The composite showed a well-distributed two-dimensional layered structure and functional groups with excellent paramagnetic performance. Two classical phosphoproteins, namely, α- and ß-caseins, were selected as model phosphorylated samples to assess the performance of the proposed enrichment technique. The magnetic carbon nitride composite exhibited high selectivity and sensitivity for phosphopeptide enrichment. The limit of detection was determined by MALDI-TOF-MS analysis to be 0.1 fmol. The selectivity of the method was investigated using the digest mixtures of α-casein, ß-casein, and bovine serum albumin (BSA) with different mass ratios (1∶1∶1000, 1∶1∶2000, and 1∶1∶5000). Direct analysis of the samples revealed the dominance of spectral signals from the abundant peptides in BSA. After enrichment with the magnetic carbon nitride composite, the high concentration of background proteins was washed away and only the signals of the phosphopeptides were captured. The signals from the casein proteins were clearly observed with little background noise, indicating the high selectivity of the composite material. The robustness of the method was tested by assessing the reusability of the same batch of magnetic carbon nitride materials over 20 cycles of enrichment. The composite showed nearly the same enrichment ability even after several cycles of reuse, demonstrating its potential applicability for a large number of clinical samples. Finally, the method was applied to the analysis of phosphopeptides from several commonly used phosphoprotein-containing samples, including skimmed milk digest, human serum, and human saliva; these samples are significant in the analysis of food quality, disease biomarkers, and liquid biopsies for cancer. Without enrichment, no phosphopeptide was detected because of the high abundance of nonphosphopeptide materials dominating the spectral signals obtained. After pretreatment with the developed magnetic carbon nitride composite, most of the phosphosites were identified with high selectivity and sensitivity via MALDI-TOF-MS. These results revealed the practicality of the developed approach for clinical applications. In addition, our method may potentially be employed for phosphoproteomics with real complex biological samples.


Subject(s)
Nitriles , Phosphopeptides , Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization , Phosphopeptides/analysis , Phosphopeptides/chemistry , Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization/methods , Nitriles/chemistry , Caseins/chemistry , Caseins/analysis , Phosphorylation , Proteomics/methods , Magnetics
14.
Magn Reson Med ; 2024 Jun 24.
Article in English | MEDLINE | ID: mdl-38923628

ABSTRACT

PURPOSE: Non-contrast-enhanced time of flight (TOF) is a standard method for magnetic resonance angiography used to depict vessel morphology. TOF is commonly performed with a 3D steady-state acquisition, employing a short repetition time to support high resolution imaging. At 7 T, TOF exhibits substantial increase in SNR and contrast, improving its clinical value. However, one of the remaining challenges, exacerbated at 7 T, is the presence of artifacts due to pulsatile blood flow, especially near major blood vessels. In this study we examine a method to significantly reduce these artifacts. METHODS: We recently introduced a new "local-scrambling" approach that semi-randomizes the acquisition order of the phase encodes, to achieve a controllable cutoff frequency above which the artifacts are drastically reduced. With this approach, artifacts resulting from fast local fluctuations such as cardiac pulsation are significantly reduced. In this study, we explore the ability of this local-scrambling approach to reduce pulsatile blood flow artifacts in a 3D TOF acquisition. Cartesian line-by-line and center-out ordering, with and without local-scrambling, were compared in simulations and in human brain imaging at 3 and 7 T scanners. RESULTS: In the simulations the artifact intensity showed a 10-fold reduction using local-scrambling compared to line-by-line and 4-fold compared to center-out ordering. In vivo results show that artifacts are much more pronounced at 7 T compared to 3 T, and in both cases they are effectively reduced by local-scrambling. CONCLUSION: Local-scrambling improves image quality for both line-by-line and center-out ordering. This approach can easily be implemented in the scanner without any changes to the reconstruction.

15.
Sensors (Basel) ; 24(12)2024 Jun 07.
Article in English | MEDLINE | ID: mdl-38931494

ABSTRACT

Due to limitations in current motion tracking technologies and increasing interest in alternative sensors for motion tracking both inside and outside the MRI system, in this study we share our preliminary experience with three alternative sensors utilizing diverse technologies and interactions with tissue to monitor motion of the body surface, respiratory-related motion of major organs, and non-respiratory motion of deep-seated organs. These consist of (1) a Pilot-Tone RF transmitter combined with deep learning algorithms for tracking liver motion, (2) a single-channel ultrasound transducer with deep learning for monitoring bladder motion, and (3) a 3D Time-of-Flight camera for observing the motion of the anterior torso surface. Additionally, we demonstrate the capability of these sensors to simultaneously capture motion data outside the MRI environment, which is particularly relevant for procedures like radiation therapy, where motion status could be related to previously characterized cyclical anatomical data. Our findings indicate that the ultrasound sensor can track motion in deep-seated organs (bladder) as well as respiratory-related motion. The Time-of-Flight camera offers ease of interpretation and performs well in detecting surface motion (respiration). The Pilot-Tone demonstrates efficacy in tracking bulk respiratory motion and motion of major organs (liver). Simultaneous use of all three sensors could provide complementary motion information outside the MRI bore, providing potential value for motion tracking during position-sensitive treatments such as radiation therapy.


Subject(s)
Magnetic Resonance Imaging , Humans , Magnetic Resonance Imaging/methods , Respiration , Liver/diagnostic imaging , Liver/physiology , Movement/physiology , Urinary Bladder/diagnostic imaging , Urinary Bladder/physiology , Algorithms , Deep Learning , Motion , Ultrasonography/methods
16.
Igaku Butsuri ; 44(2): 29-35, 2024.
Article in Japanese | MEDLINE | ID: mdl-38945880

ABSTRACT

This is an explanatory paper on Sun Il Kwon et al., Nat. Photon. 15: 914-918, 2021 and some parts of this manuscript are translated from the paper. Medical imaging modalities such as X-ray computed tomography, Magnetic resonance imaging, positron emission tomography (PET), and single photon emission computed tomography, require image reconstruction processes, consequently constraining them to form cylindrical shapes. However, among them, only PET can use additional information, so called time of flight, on an event-by-event basis. If coincidence time resolution (CTR) of PET detectors improved to 30 ps, which corresponds to spatial resolution of 4.5 mm, directly localizing electron-positron annihilation point is possible, allowing us to circumvent image reconstruction processes and free us from the geometric constraint. We call this concept direct positron emission imaging (dPEI). We have developed ultrafast radiation detectors by focusing on Cherenkov photon detection. Furthermore, the CTR of 32 ps being equivalent to 4.8 mm spatial resolution is achieved by combining deep learning-based signal processing with the detectors. In this article, we explain how we developed the detectors and demonstrated the first dPEI using different types of phantoms, how we will tackle limitations to be addressed to make the dPEI more practical, and how dPEI will emerge as an imaging modality in nuclear medicine.


Subject(s)
Image Processing, Computer-Assisted , Positron-Emission Tomography , Image Processing, Computer-Assisted/methods , Phantoms, Imaging , Photons , Positron-Emission Tomography/instrumentation , Positron-Emission Tomography/methods , Time Factors
17.
J Pharm Biomed Anal ; 247: 116257, 2024 Sep 01.
Article in English | MEDLINE | ID: mdl-38815520

ABSTRACT

Zhi-Ke-Bao pills (ZKB), a traditional Chinese medicine preparation composed of 13 herbs, is generally used to treat cough caused by external wind cold, phlegm, etc in clinical applications, and it plays a core role in relieving cough caused by COVID-19 and influenza in China. Till now, the understanding of its chemical constituents was dramatically limited due to its chemical complexity, restricting its clinical application or development. In this work, a developed ultra-high performance liquid chromatography coupled to quadrupole time-of-flight mass spectrometry (UPLC-Q/TOF MS) method, a targeted and non-targeted strategy and network pharmacology were used to comprehensively characterize the chemical compositions in ZKB and predict its mechanism against cough. A total of 164 compounds (148 targeted compounds and 16 non-targeted ones) were identified or tentatively characterized in ZKB, including 65 flavonoids, 25 alkaloids, 19 organic acids, 41 saponins, 9 coumarins, 2 phenylpropanoids, 2 anthraquinones, and 1 other types. Among them, 37 compounds were unambiguously identified by comparison to reference standards. Meanwhile, the fragmentation behaviors of five main chemical structure types were also summarized. 309 targets and two core signaling pathways of ZKB against cough were predicted by network pharmacology, including MAPK and PI3K-Akt signaling pathways. It was the first time to characterize the chemical compounds of ZKB and reveal its potential mechanism against cough, providing the material basis for further quality control or pharmacodynamic evaluation of ZKB.


Subject(s)
Cough , Drugs, Chinese Herbal , Network Pharmacology , Drugs, Chinese Herbal/chemistry , Drugs, Chinese Herbal/pharmacology , Drugs, Chinese Herbal/analysis , Chromatography, High Pressure Liquid/methods , Cough/drug therapy , Humans , Mass Spectrometry/methods , Medicine, Chinese Traditional/methods , Antitussive Agents/pharmacology , Antitussive Agents/chemistry , Antitussive Agents/analysis , COVID-19 Drug Treatment , Alkaloids/analysis , Alkaloids/chemistry , Alkaloids/pharmacology
18.
Saudi Med J ; 45(5): 458-467, 2024 May.
Article in English | MEDLINE | ID: mdl-38734425

ABSTRACT

The aim of this study was to go through the molecular methods used for typing of carbapenem-resistant Acientobacter baumannii (CRAB) isolates for investigating the molecular epidemiology all over the world. Multiple typing techniques are required to understand the source and nature of outbreaks caused by Acientobacter baumannii (A. baumannii) and acquired resistance to antimicrobials. Nowadays, there is gradual shift from traditional typing methods to modern molecular methods to study molecular epidemiology and infection control. Molecular typing of A. baumannii strains has been revolutionized significantly in the last 2 decades. A few sequencing-based techniques have been proven as a breakthrough and opened new prospects, which have not been achieved by the traditional methods. In this review, discussed different pre-existing and recently used typing methods to explore the molecular epidemiology of A. baumannii pertaining in context with human infections.


Subject(s)
Acinetobacter Infections , Acinetobacter baumannii , Molecular Epidemiology , Molecular Typing , Acinetobacter baumannii/genetics , Acinetobacter baumannii/isolation & purification , Humans , Molecular Epidemiology/methods , Acinetobacter Infections/epidemiology , Acinetobacter Infections/microbiology , Molecular Typing/methods , Bacterial Typing Techniques/methods
19.
Quant Imaging Med Surg ; 14(5): 3417-3431, 2024 May 01.
Article in English | MEDLINE | ID: mdl-38720837

ABSTRACT

Background: Computed tomography angiography (CTA) and digital subtraction angiography (DSA) usually raise the risk of potential malignancies with cumulative radiation doses. Current time-of-flight magnetic resonance angiography (TOF-MRA) (dubbed as cTOF), which is based on Cartesian sampling mode, may show limited diagnostic conspicuity at sinuous or branching regions. It is also prone to relatively high false positive diagnoses and undesirable display of distal intracranial vessels. This study aimed to use spiral TOF-MRA (sTOF) as a noninvasive alternative to explore possible improvement, such that the application of magnetic resonance angiography (MRA) can be extended to facilitate clinical examination or cerebrovascular disease diagnosis and follow-up studies. Methods: Initially, 37 patients with symptoms of dizziness or transient ischemic attack were consecutively recruited for suspected intracranial vascular disease examination from Zhongshan Hospital of Xiamen University between July 2020 and April 2021 in this cross-sectional prospective study. After excluding 1 patient with severe scanning artifacts, 1 patient whose scanning scope did not meet the requirement, and 1 patient with confounding tumor lesions, a total of 34 participants were included according to the inclusion and exclusion criteria. Each participant underwent intracranial vascular imaging with both sTOF and cTOF sequences on a 3.0 T MR scanner with a conventional head-neck coil of 16 channels. Contrast CTA or DSA was also performed for 15 patients showing pathology. Qualitative comparisons in terms of image quality and diagnostic efficacy ratings, quantitative comparisons in terms of signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), vessel length, and sharpness were evaluated. Pair-wise Wilcoxon test was performed to evaluate the imaging quality derived from cTOF and sTOF acquisitions and weighted Cohen's Kappa was conducted to assess the rating consistency between different physicians. Results: Compared to cTOF, sTOF showed better performance with fewer artifacts. It can effectively alleviate false positives of normal vessels being misdiagnosed as aneurysm or stenosis. Improved conspicuity was observed in cerebral distal regions with more clearly identifiable vasculature at finer scales. Quantitative comparisons in selected regions revealed significant improvement of sTOF in SNR (P<0.01 or P<0.001), CNR (P<0.001), vessel length (P<0.001), and sharpness (P<0.001) as compared to cTOF. Besides, sTOF can depict details of M1 and M2 segments of middle cerebral artery (MCA) at metallic implant region, showing its resistance to magnetic susceptibility. Conclusions: The sTOF shows higher imaging quality and lesion detectability with reduced artifacts and false positives, representing a potentially feasible surrogate in intracranial vascular imaging for future clinic routines.

20.
Talanta ; 277: 126327, 2024 May 25.
Article in English | MEDLINE | ID: mdl-38805944

ABSTRACT

Single photon ionization time-of-flight mass spectrometry (SPI-TOF-MS) is a powerful analytical technique for real-time detection of trace VOCs. However, efficient ion transmission within the ionization chamber has always been a challenging issue in SPI-TOF-MS. In this study, a novel ion guide termed the Segmented Focus Quadrupole Ion Guide (SFQ-IG) was introduced for SPI-TOF-MS. The SFQ-IG device consists of 12 printed circuit boards (PCB), each containing four quarter-ring electrodes with inner diameters progressively decreasing from 26 to 4 mm. The simulation results demonstrated that SFQ-IG exhibited superior ion transmission efficiency than both ion funnel (IF) field and direct current-only (DC-only) field. By integrating into a SPI-TOF-MS, this ion guide was optimized in terms of the ionization source pressure, direct current gradient, and radio frequency amplitude. Further comparative experiments demonstrated that the SPI-TOF-MS with the SFQ-IG exhibited higher sensitivity than both the IF field (1.3-7.4 times) and DC-only field (3.5-8.8 times) for the test VOCs. The improvements in limit of detection (LOD) with the SFQ-IG ranged from 1.6 to 5.3 times compared to the DC-only field for the test VOCs. Fabricated using PCB technology, the SFQ-IG is characterized by its cost-effectiveness, compact size, and high transmission efficiency, facilitating its integration into other mass spectrometers.

SELECTION OF CITATIONS
SEARCH DETAIL
...