Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Language
Publication year range
1.
Arq. bras. med. vet. zootec. (Online) ; 71(6): 1909-1916, Nov.-Dec. 2019. ilus
Article in English | LILACS, VETINDEX | ID: biblio-1055110

ABSTRACT

The study evaluated sonographic and serologic exams performed for early (20 to 30d) diagnosis of pregnancy. One hundred-twenty (n= 120) bovine recipients were synchronized (estrous=D0) and timed embryo transferred (TET, D7) with fresh in vitro produced embryos. In the first trial (n= 46), diagnosis of pregnancy was performed on day 20 (D20) by detecting CL blood flow (BF) and by Pregnancy-Associated Glycoproteins (PAGs) serology. In the second trial (n= 30), pregnancy diagnosis was performed on D25 by ultrasound visualization of uterine contents and by PAGs serology. In the last trial, PAG's serology was performed on D30. Ultrasonographic detection of the uterine contents and embryo viability performed on D30 (DG30) was considered the gold standard. The PROC FREQ procedure was used to test the agreement between diagnostic methods. On D20, the Doppler ultrasonography of the CL had showed high sensitivity (100%), but only moderate specificity (53.3%). On the same day, serologic diagnostic had no agreement (k= -0.08, P< 0.46) with the gold standard, with very low sensitivity (6.3%). However, the sensitivity of the serologic exam increased dramatically (from 6.3 to 100%) from D20 to D25, and it contributed to detect false negatives from the ultrasound diagnosis, improving the overall accuracy from 90% to 96.7%.(AU)


O estudo foi planejado para correlacionar exames ultrassonográficos e sorológicos realizados para o diagnóstico precoce (20 a 30d) de gestação. Cento e vinte (n= 120) receptoras bovinas foram sincronizadas (estro=D0), e embriões frescos produzidos in vitro foram transferidos em tempo fixo (TETF, D7). No experimento 1 (n= 46), o diagnóstico de gestação foi realizado no D20, pela detecção do fluxo sanguíneo do CL e pela sorologia de glicoproteínas associadas à gestação (PAGs). No experimento 2 (n= 30), a detecção da gestação foi realizada por meio da visualização do conteúdo do útero e também pela sorologia para PAGs. No experimento 3, a sorologia para PAGs foi realizada no D30. Em todos os experimentos, a visualização ultrassonográfica da vesícula e da viabilidade embrionária, realizada no D30, foi considerada padrão-ouro. O procedimento PROC FREQ testou o nível de concordância dos métodos diagnósticos. No D20, o diagnóstico baseado na vascularização do CL mostrou alta sensibilidade (100%) e apenas moderada especificidade (53,3%). Nesse mesmo dia, o diagnóstico sorológico não apresentou concordância (k=-0,08, P<0,46) com o padrão-ouro, além de baixa sensibilidade (6,3%). No entanto, a sensibilidade do exame sorológico aumentou drasticamente (6,3 para 100%) do D20 para o D25, contribuindo para detectar falsos negativos diagnosticados pela ultrassonografia, melhorando a acurácia (90 para 96,7%).(AU)


Subject(s)
Animals , Female , Pregnancy , Cattle , Pregnancy, Animal/blood , Serologic Tests/veterinary , Glycoproteins/analysis , Ultrasonography, Doppler, Color/veterinary , Embryo Transfer/veterinary
2.
Theriogenology ; 84(2): 237-41, 2015 Jul 15.
Article in English | MEDLINE | ID: mdl-25892341

ABSTRACT

The aim of the present study was to use blood flow evaluation of the CL at 14 days after embryo transfer to detect nonpregnant animals and optimize the management of bovine recipients. The estrous cycle was synchronized in 165 recipients, and the day of expected ovulation was considered to be Day 0. Embryo transfer was performed 7 days later, on Day 7. On Day 21, pregnancy was diagnosed on the basis of blood flow evaluation of the CL (DG21-predictive diagnostic). To validate this methodology, visual scores for blood flow were compared to objective data extracted from CL ultrasound images recorded in the Doppler mode. The size was also evaluated using recorded images of the CL in the B mode. Blood samples were also collected for further analysis of the progesterone (P4) concentration. The diagnosis of pregnancy was confirmed at 35 days after estrus (DG35-definitive diagnostic). The DG21 showed that 55.2% (90 of 163) of the animals were presumptively pregnant, and this value was higher (P < 0.04) than that obtained at DG35 (43.6%, 71 of 163). The predictive diagnostic achieved moderate specificity (79.3%) for the detection of pregnancy, but most importantly, high sensitivity (100%) for the detection of nonpregnant recipients. The overall accuracy of the diagnosis was 88.3%. The P4 concentrations were different (P < 0.02) and correlated with each visual score assigned for the CL size. Visual scores for CL blood flow were also efficient (P < 0.0001) to distinguish animals with different levels of P4; however, P4 concentrations were higher for scores 1 and 2 (high and regular blood flow, respectively) than those for score 3 (low blood flow). This technique showed high sensitivity and facilitated the early detection of nonpregnant animals. The DG21 would allow about 79.3% of nonpregnant animals to be resynchronized 9 to 14 days earlier, when compared to conventional management based on pregnancy diagnosis at Days 30 to 35.


Subject(s)
Cattle/physiology , Corpus Luteum/blood supply , Embryo Transfer/veterinary , Animals , Corpus Luteum/diagnostic imaging , Female , Gestational Age , Pregnancy , Pregnancy Tests/veterinary , Progesterone/blood , Sensitivity and Specificity , Ultrasonography
SELECTION OF CITATIONS
SEARCH DETAIL
...