Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Publication year range
1.
Arq. bras. oftalmol ; 80(5): 309-312, Sept.-Oct. 2017. tab
Article in English | LILACS | ID: biblio-888139

ABSTRACT

ABSTRACT Purpose: To evaluate the corneal biomechanical features and central corneal thickness in ankylosing spondylitis patients and to evaluate correlations of these parameters with disease activity. Methods: The study included 51 patients diagnosed with ankylosing spondylitis (mean age, 40.80 ± 13.15 years; range, 18-72 years) and 34 age- and sex-matched healthy controls (mean age, 42.00 ± 12.32 years; range, 18-60 years). All underwent a complete ophthalmological and physical examination, including visual acuity testing and biomicroscopic anterior and posterior segment examinations. Corneal hysteresis, corneal resistance factor, Goldmann-correlated intraocular pressure, and corneal compensated intraocular pressure were evaluated with an ocular response analyzer, and the central corneal thickness was measured with Sirius® corneal tomography. The Bath Ankylosing Spondylitis Disease Activity Index, Functional Index, and Metrology Index scores were recorded. Results: In the ankylosing spondylitis patients, the mean disease duration was 7.73 ± 6.05 (range, 1-30) years. There was no statistically significant difference between the patients and controls in the corneal biomechanical features. The Goldmann-correlated intraocular pressure and corneal compensated intraocular pressure both showed positive correlations with age (p=0.003 and p=0.001, res­pectively). There was a negative correlation between corneal hysteresis and disease duration (p=0.002), and between central corneal thickness and the Bath Ankylosing Spondylitis Metrology Index score (p=0.003). Conclusion: This study demonstrated a significant negative correlation between corneal hysteresis and disease duration in ankylosing spondylitis patients. Furthermore, the central corneal thickness value decreased with an increase in Bath Ankylosing Spondylitis Metrology Index score, which may result in an underestimate of intraocular pressure readings and thus an inaccurate risk assessment of glaucoma.


RESUMO Objetivo: Avaliar as características biomecânicas da córnea e espessura central da córnea em pacientes com espondilite anquilosante e analisar a correlação destes parâmetros no grupo de estudo com a atividade da doença. Métodos: Foram incluídos no estudo 51 pacientes com diagnóstico de espondilite anquilosante e 34 controles saudáveis com idade e sexo. Todos os sujeitos foram submetidos a um exame oftalmológico e físico completo, incluindo exames de acuidade visual, exames de segmento anterior e posterior biomicroscópicos. Foram avaliados o coeficiente de resistência da córnea, a pressão intraocular correlacionada com Goldmann e a pressão intraocular compensada da córnea com o analisador de resposta ocular, a espessura corneana central com a tomografia corneana pelo Sirius®. Se o índice de atividade da doença de espondilite anquilosante de banho, o índice funcional de espondilite anquilosante de banho, o índice de metrologia de espondilite anquilosante de banho. Resultados: Foram incluídos no estudo 51 pacientes com idade média de 40,80 ± 13,15 (intervalo: 18-72) anos e 34 casos de controle com idade média de 42,00 ± 12,32 (intervalo: 18-60) anos. No grupo espondilite anquilosante a duração média da doença foi de 7,73 ± 6,05 (1,00-30,00) anos. Não houve diferença estatisticamente significante entre dois grupos quanto às características biomecânicas da córnea. Na análise de correlação, no grupo de estudo; pressão intraocular correlacionada com Goldmann e pressão intraocular compensada da córnea estavam positivamente correlacionados com a idade (p=0,003, p=0,001, respectivamente). Houve uma correlação negativa entre a duração da doença e CH (p=0,002), e entre índice de metrologia de espondilite anquilosante de banho e espessura corneana central (p=0,003). Conclusão: Este estudo demonstrou correlação negativa significativa entre a duração da doença e a histerese corneal em pacientes com espondilite anquilosante. Além disso, com um aumento na pontuação de índice de metrologia de espondilite anquilosante de banho, o valor de espessura corneana central também estava di­minuindo o que pode causar uma diminuição nas leituras de pressão intraocular artificialmente e resultar em avaliação de risco imprecisa de glaucoma.


Subject(s)
Humans , Male , Female , Adolescent , Adult , Middle Aged , Aged , Young Adult , Spondylitis, Ankylosing/pathology , Cornea/pathology , Corneal Diseases/pathology , Spondylitis, Ankylosing/complications , Biomechanical Phenomena , Severity of Illness Index , Case-Control Studies , Cell Count , Glaucoma/etiology , Glaucoma/physiopathology , Risk Factors , Cornea/physiopathology , Corneal Diseases/complications , Corneal Diseases/physiopathology , Corneal Topography , Corneal Pachymetry , Intraocular Pressure
2.
Rev. bras. oftalmol ; 73(4): 220-224, Jul-Aug/2014. tab, graf
Article in Portuguese | LILACS | ID: lil-730578

ABSTRACT

Objetivo: Verificar índices tomográficos do pré-operatório de pacientes com ceratocone submetidos à crosslinking corneano (CXL) como fatores preditivos para a melhora na acuidade visual corrigidas (AVc) após um ano. Métodos: Estudo retrospectivo que incluiu 63 olhos de 53 pacientes com ceratocone progressivo submetidos à CXL segundo o protocolo de Dresden: deseptelização corneana, riboflavina 0,1% por 30 minutos e luz ultra-violeta A (UVA) a uma irradiância de 3mW/cm2 por 30 minutos. Foram avaliados exames de tomografia corneana com sistema de Scheimpflug rotacional (Pentacam, Oculus) antes do CXL e a acuidade visual corrigida antes e após a cirurgia. A análise estatística foi feita com o teste de Kolmorov-Smirnov, teste t de student e curvas de característica operador-receptor (ROC). Resultados: Houve diferença estatisticamente significante (p<0,05) entre os pacientes que obtiveram melhora de AVc em um ano e os que não experimentaram melhora na AVc nesse período nos índices tomográficos pré-operatórios relacionados com espessura e volume corneano. Entre os pacientes que obtiveram melhora na AVc todos possuíam volume corneano em 6,0mm maior que 14,55mm3 e 97,2% deles possuíam volume corneano em 6,5mm maior que 17,76mm3. Assim como, 94,29% desses pacientes apresentavam paquimetria média em 4,0mm maior que 487 μm e 82,86% paquimetria no ponto mais fino maior de 421 μm. Conclusão: Pacientes com ceratocone menos avançado (volume e espessura da córnea maiores) no período pré-operatório obtiveram mais chances de ter melhora da AVc um ano após CXL. Estudos prospectivos envolvendo outras variáveis relacionadas com a aberrometria total e o estudo biomecânico da córnea são relevantes para se aumentar a capacidade prognóstica do resultado após CXL. .


Purpose: To verify pre-operative tomographic indices as predictive parameters for the improvement in best corrected visual acuity (BCVA) in one year after corneal collagen crosslinking (CXL) procedure for keratoconus. Methods: Retrospective study that included 63 eyes of 53 patients with progressive keratoconus submitted to CXL following the Dresden’s protocol: topical anesthesia, 9.0 mm of epithelial abrasion, riboflavin 0.1% drops for 30 minutes and ultraviolet-light A (UVA) with an irradiance of 3mW/cm2 for 30 minutes. Corneal tomography taken by Scheimplug rotational system (Pentacam, Oculus) before CXL was evaluated along with pre and 1 year post-operative BCVA. Statistical analysis was accomplished with the Kolmogorov-Smirnov test, student’s t-test and Receiver Operating Characteristic (ROC) curve. Results: There were statistically significant differences (p<0.05) between patients who improved BCVA in one year after CXL and those who did not experienced improvement in BCVA in the same period of time in the pre-operative tomographic indices related to corneal volume and thickness. Among those who had its BCVA improved all of them had a corneal volume in 6.0mm grater then 14.55mm3 and 97.2% of them had corneal volume in 6.5mm grater then 17.76mm3. So with 94.29% of them hadthickness in 4.0mm grater then 487μm and 82.86% had thickness on the thinnest point grater then 421μm. Conclusion: Patients with less advanced keratoconus (grater corneal volume and thickness) in the pre-operative had more chances to improve its BCVA in one year after CXL. Prospective studies involving others variables related to total aberrometry and corneal biomechanics are relevant to increase the prognostic capability of CXL result. .


Subject(s)
Humans , Male , Female , Adolescent , Adult , Middle Aged , Prognosis , Riboflavin/therapeutic use , Ultraviolet Rays , Cross-Linking Reagents , Keratoconus/therapy , Preoperative Care , Retrospective Studies , Collagen/radiation effects , Collagen/metabolism , Photosensitizing Agents/therapeutic use , Cornea/drug effects , Cornea/radiation effects , Cornea/metabolism , Tomography, Optical Coherence , Keratoconus/physiopathology , Keratoconus/metabolism
SELECTION OF CITATIONS
SEARCH DETAIL
...