1.
Arch. argent. pediatr ; 121(5): e202202801, oct. 2023. tab, ilus
Article in English, Spanish | LILACS, BINACIS | ID: biblio-1509956

ABSTRACT

Las hemoglobinopatías son trastornos genéticos que afectan a la molécula de hemoglobina (Hb). Las mutaciones en las cadenas a o b que alteran el tetrámero de Hb pueden modificar la capacidad de la molécula para unirse al oxígeno. Las hemoglobinopatías con baja afinidad al oxígeno pueden presentarse con cianosis y una lectura alterada de la oximetría de pulso, lo que lleva a pruebas innecesarias y, a veces, invasivas para descartar afecciones cardiovasculares y respiratorias. En el siguiente reporte de caso, presentamos a una paciente pediátrica, asintomática, que se presentó a la consulta por detección de desaturación en oximetría de pulso. Las pruebas de laboratorio iniciales mostraron una anemia normocítica, normocrómica. Las muestras de gas venoso demostraron una p50 elevada. Después de extensas herramientas de diagnóstico, se diagnosticó una variante de Hb con baja afinidad al oxígeno, Hb Denver.


Hemoglobinopathies are genetic disorders that affect the hemoglobin (Hb) molecule. Mutations in the alpha or beta chains altering the Hb tetramer may modify the molecule's oxygen-binding capacity. Hemoglobinopathies with low oxygen affinity may occur with cyanosis and an altered pulse oximetry reading, leading to unnecessary and sometimes invasive tests to rule out cardiovascular and respiratory conditions. In the case report described here, we present an asymptomatic pediatric patient who consulted for desaturated pulse oximetry. Her initial laboratory tests showed normocytic, normochromic anemia. Venous blood gas samples showed an elevated p50. After using extensive diagnostic tools, a variant of Hb with low oxygen affinity was diagnosed: Hb Denver.


Subject(s)
Humans , Female , Child , Hemoglobins, Abnormal/analysis , Hemoglobins, Abnormal/genetics , Hemoglobins, Abnormal/chemistry , Hemoglobinopathies/diagnosis , Hemoglobinopathies/genetics , Anemia , Oxygen , Oximetry
2.
Arch Argent Pediatr ; 121(5): e202202801, 2023 10 01.
Article in English, Spanish | MEDLINE | ID: mdl-36857142

ABSTRACT

Hemoglobinopathies are genetic disorders that affect the hemoglobin (Hb) molecule. Mutations in the alpha or beta chains altering the Hb tetramer may modify the molecule's oxygen-binding capacity. Hemoglobinopathies with low oxygen affinity may occur with cyanosis and an altered pulse oximetry reading, leading to unnecessary and sometimes invasive tests to rule out cardiovascular and respiratory conditions. In the case report described here, we present an asymptomatic pediatric patient who consulted for desaturated pulse oximetry. Her initial laboratory tests showed normocytic, normochromic anemia. Venous blood gas samples showed an elevated p50. After using extensive diagnostic tools, a variant of Hb with low oxygen affinity was diagnosed: Hb Denver.


Las hemoglobinopatías son trastornos genéticos que afectan a la molécula de hemoglobina (Hb). Las mutaciones en las cadenas a o b que alteran el tetrámero de Hb pueden modificar la capacidad de la molécula para unirse al oxígeno. Las hemoglobinopatías con baja afinidad al oxígeno pueden presentarse con cianosis y una lectura alterada de la oximetría de pulso, lo que lleva a pruebas innecesarias y, a veces, invasivas para descartar afecciones cardiovasculares y respiratorias. En el siguiente reporte de caso, presentamos a una paciente pediátrica, asintomática, que se presentó a la consulta por detección de desaturación en oximetría de pulso. Las pruebas de laboratorio iniciales mostraron una anemia normocítica, normocrómica. Las muestras de gas venoso demostraron una p50 elevada. Después de extensas herramientas de diagnóstico, se diagnosticó una variante de Hb con baja afinidad al oxígeno, Hb Denver.


Subject(s)
Anemia , Hemoglobinopathies , Hemoglobins, Abnormal , Humans , Child , Female , Hemoglobins, Abnormal/genetics , Hemoglobins, Abnormal/analysis , Hemoglobins, Abnormal/chemistry , Oximetry , Hemoglobinopathies/diagnosis , Hemoglobinopathies/genetics , Oxygen
3.
Glob Pediatr Health ; 8: 2333794X211016790, 2021.
Article in English | MEDLINE | ID: mdl-34036124

ABSTRACT

Monitoring CO2 levels in intubated neonates is highly relevant in the face of complications associated with altered CO2 levels. Thus, this review aims to present the scientific evidence in the literature regarding the correlation between arterial carbon dioxide measured by non-invasive methods in newborns submitted to invasive mechanical ventilation. The search was carried out from January 2020 to January 2021, in the Scopus, Medline, The Cochrane Library, Web of Science, CINAHL and Embase databases. Also, a manual search of the references of included studies was performed. The main descriptors used were: "capnography," "premature infant," "blood gas analysis," and "mechanical ventilation." As a result, 221 articles were identified, and 18 were included in this review. A total of 789 newborns were evaluated, with gestational age between 22.8 and 42.2 weeks and birth weight between 332 and 4790 g. Capnometry was the most widely used non-invasive method. In general, the correlation and agreement between the methods evaluated in the studies were strong/high. The birth weight did not influence the results. The gestational age of fewer than 37 weeks implied, in its majority, a moderate correlation and agreement. Therefore, we can conclude that there was a predominance of a strong correlation between arterial blood gases and non-invasive methods, although there are variations found in the literature. Even so, the results were promising and may provide valuable data for future studies, which are necessary to consolidate non-invasive methods as a reliable and viable alternative to arterial blood gasometry.

4.
Rev. habanera cienc. méd ; 17(4): 555-566, jul.-ago. 2018. tab
Article in Spanish | LILACS, CUMED | ID: biblio-978551

ABSTRACT

Introducción: La cavidad abdominal y la caja torácica se encuentran separadas por el diafragma, por lo que las variaciones en las presiones dentro de una, repercuten sobre las presiones de la otra. La hipertensión intraabdominal es hoy una entidad frecuente en el paciente crítico en el que constituye un factor de riesgo importante de complicaciones y mortalidad, ya que influye sobre órganos y sistemas. Objetivo: Relacionar la presión intraabdominal con presiones de la ventilación artificial mecánica y parámetros de la función respiratoria, cardiovascular y renal. Material y Métodos: Se realizó un estudio descriptivo y prospectivo de la presión intraabdominal en pacientes sometidos a ventilación mecánica, con enfermedades clínicas y quirúrgicas, en las Unidades de Cuidados Intensivos del Hospital Clínico Quirúrgico Arnaldo Milán Castro, durante el período comprendido entre enero 2014 hasta diciembre 2015. Resultados: Los pacientes clínicos con presiones de la vía aérea elevadas mostraron valores más altos de presión intraabdominal, y aquellos pacientes postquirúrgicos que cursaron con niveles altos de presión dentro del abdomen también presentaron los valores más elevados de presión pico y media registradas en el ventilador mecánico. Conclusiones: La tensión arterial media, el ritmo diurético y la saturación periférica de oxígeno disminuyeron, mientras que la presión venosa central, la presión parcial de dióxido de carbono en sangre y la creatinina aumentó ante los aumentos de la presión dentro del abdomen(AU)


Introduction: The abdominal cavity and the thoracic cage are separated by the diaphragm; therefore, the variations in the pressures within one of them have an effect on the pressures of the other. At present, intra-abdominal hypertension is a frequent entity in the critically ill patient, which constitutes an important risk factor for complications and mortality since it influences on different organs and systems. Objective: To relate intra-abdominal pressure with mechanical artificial ventilation pressures and parameters of respiratory, cardiovascular and renal function. Material and Methods: A descriptive prospective study of intra-abdominal pressure was conducted in patients undergoing mechanical ventilation with clinical and surgical diseases in the Intensive Care Units of the Arnaldo Milán Castro Hospital, during the period between January 2014 until December 2015. Results: Clinical patients with high values of airway pressures showed higher values of intra-abdominal pressure, and those post-surgical patients who presented with high levels of pressure inside the abdomen indicated the highest values of peak and average pressure recorded in the mechanical ventilator. Conclusions: Mean arterial pressure, diuretic rate and peripheral oxygen saturation decreased, whereas the central venous pressure, the partial pressure of carbon dioxide in blood, and creatinine increased due to raises in pressure within the abdomen(AU)


Subject(s)
Humans , Male , Female , Respiration, Artificial/adverse effects , Intra-Abdominal Hypertension/complications , Intra-Abdominal Hypertension/etiology , Epidemiology, Descriptive , Prospective Studies , Critical Care/methods