Neuroimage ; 297: 120738, 2024 Jul 14.
Article in English | MEDLINE | ID: mdl-39009248

ABSTRACT

Ultrasound imaging stands as the predominant modality for neonatal health assessment, with recent advancements in ultrafast Doppler (µDoppler) technology offering significant promise in fields such as neonatal brain imaging. Combining µDoppler with high-frequency ultrasound (HF-µDoppler) presents a potential efficient avenue to enhance in vivo microvascular imaging in small animals, notably newborn rats, a crucial preclinical animal model for neonatal disease and development research. It is necessary to verify the imaging performance of HF-µDoppler in preclinical trials. This study investigates the microvascular imaging capabilities of HF-µDoppler using a 30 MHz high-frequency linear array probe in newborn rats. Results demonstrate the clarity of cerebral microvascular imaging in rats aged 1 to 7 postnatal days, extending to whole-body microvascular imaging, encompassing the central nervous system, including the brain and spinal cord. In conclusion, HF-µDoppler technology emerges as a reliable imaging tool, offering a new perspective for preclinical investigations into neonatal diseases and development.

2.
Heliyon ; 10(11): e31742, 2024 Jun 15.
Article in English | MEDLINE | ID: mdl-38845994

ABSTRACT

This review aims to explore the current application of Cranial Ultrasound Screening (CUS) in the diagnosis and treatment of brain diseases in extremely preterm infants. It also discusses the potential role of emerging ultrasound-derived technologies such as Super Microvascular Structure Imaging (SMI), Shear Wave Elastography (SWE), Ultrafast Doppler Ultrasound (UfD), and 3D ventricular volume assessment and automated segmentation techniques in clinical practice. A systematic search of medical databases was conducted using the keywords "(preterm OR extremely preterm OR extremely low birth weight) AND (ultrasound OR ultrasound imaging) AND (neurodevelopment OR brain development OR brain diseases OR brain injury OR neuro*)" to identify relevant literature. The titles, abstracts, and full texts of the identified articles were carefully reviewed to determine their relevance to the research topic. CUS offers unique advantages in early screening and monitoring of brain diseases in extremely preterm infants, as it can be performed at the bedside without the need for anesthesia or special monitoring. This technique facilitates early detection and intervention of conditions such as intraventricular hemorrhage, white matter injury, hydrocephalus, and hypoxic-ischemic injury in critically ill preterm infants. Continuous refinement of the screening and follow-up processes provides reliable clinical decision-making support for healthcare professionals and parents. Emerging ultrasound technologies, such as SWE, SMI, and UfD, are being explored to provide more accurate and in-depth understanding of brain diseases in extremely preterm infants. SWE has demonstrated its effectiveness in assessing the elasticity of neonatal brain tissue, aiding in the localization and quantification of potential brain injuries. SMI can successfully identify microvascular structures in the brain, offering a new perspective on neurologic diseases. UfD provides a high-sensitivity and quantitative imaging method for the prevention and treatment of neonatal brain diseases by detecting subtle changes in red blood cell movement and accurately assessing the status and progression of brain diseases. CUS and its emerging technologies have significant applications in the diagnosis and treatment of brain diseases in extremely preterm infants. Future research aims to address current technical challenges, optimize and enhance the clinical decision-making capabilities related to brain development, and improve the prevention and treatment outcomes of brain diseases in extremely preterm infants.

3.
Ultrasonics ; 140: 107307, 2024 May.
Article in English | MEDLINE | ID: mdl-38579486

ABSTRACT

BACKGROUND AND OBJECTIVE: With the development of advanced clutter-filtering techniques by singular value decomposition (SVD) and leveraging favorable acquisition settings such as open-chest imaging by a linear high-frequency probe and plane waves, several studies have shown the feasibility of cardiac flow measurements during the entire cardiac cycle, ranging from coronary flow to myocardial perfusion. When applying these techniques in a routine clinical setting, using transthoracic ultrasound imaging, new challenges emerge. Firstly, a smaller aperture is needed that can fit between ribs. Consequently, diverging waves are employed instead of plane waves to achieve an adequate field of view. Secondly, to ensure imaging at a larger depth, the maximum pulse repetition frequency has to be reduced. Lastly, in comparison to the open-chest scenario, tissue motion induced by the heartbeat is significantly stronger. The latter complicates substantially the distinction between clutter and blood signals. METHODS: This study investigates a strategy to overcome these challenges by diverging wave imaging with an optimal number of tilt angles, in combination with dedicated clutter-filtering techniques. In particular, a novel, adaptive, higher-order SVD (HOSVD) clutter filter, which utilizes spatial, temporal, and angular information of the received ultrasound signals, is proposed to enhance clutter and blood separation. RESULTS: When non-negligible tissue motion is present, using fewer tilt angles not only reduces the decorrelation between the received waveforms but also allows for collecting more temporal samples at a given ensemble duration, contributing to improved Doppler performance. The addition of a third angular dimension enables the application of HOSVD, providing greater flexibility in selecting blood separation thresholds from a 3-D tensor. This differs from the conventional threshold selection method in a 2-D spatiotemporal space using SVD. Exhaustive threshold search has shown a significant improvement in Contrast and Contrast-to-Noise ratio for Power Doppler images filtered with HOSVD compared to the SVD-based clutter filter. CONCLUSION: With the improved settings, the obtained Power Doppler images show the feasibility of measuring coronary flow under the influence of non-negligible tissue motion in both in vitro and ex vivo.


Subject(s)
Coronary Circulation , Coronary Circulation/physiology , Phantoms, Imaging , Animals , Humans , Algorithms , Echocardiography, Doppler/methods , Image Processing, Computer-Assisted/methods , Blood Flow Velocity/physiology , Swine
4.
J Cereb Blood Flow Metab ; : 271678X241232197, 2024 Feb 10.
Article in English | MEDLINE | ID: mdl-38340789

ABSTRACT

Preterm birth is associated with cerebrovascular development disruption and can induce white matter injuries (WMI). Transfontanellar ultrasound Doppler is the most widely used clinical imaging technique to monitor neonatal cerebral vascularisation and haemodynamics based on vascular indexes such as the resistivity index (RI); however, it has poor predictive value for brain damage. Indeed, these RI measurements are currently limited to large vessels, leading to a very limited probing of the brain's vascularisation, which may hinder prognosis. Here we show that ultrafast Doppler imaging (UfD) enables simultaneous quantification, in the whole field of view, of the local RI and vessel diameter, even in small vessels. Combining both pieces of information, we defined two new comprehensive resistivity parameters of the vascular trees. First, we showed that our technique is more sensitive in the early characterisation of the RI modifications between term and preterm neonates and for the first time we could show that the RI depends both on the vessel diameter and vascular territory. We then showed that our parameters can be used for early prediction of WMI. Our results demonstrate the potential of UfD to provide new biomarkers and pave the way for continuous monitoring of neonatal brain resistivity.

5.
Ultrasound Med Biol ; 50(4): 484-493, 2024 04.
Article in English | MEDLINE | ID: mdl-38242743

ABSTRACT

OBJECTIVE: Current medical ultrasound systems possess limited sensitivity in detecting slow and weak blood flow during the early stages of rheumatoid arthritis (RA), leading to potential misdiagnosis. Ultrafast Doppler is capable of detecting slow and weak flow. This study was aimed at evaluating the diagnostic value of ultrafast Doppler for RA. METHODS: Thirty-three RA patients (19 established, 14 early stage) and 15 healthy participants were enrolled. A programmable imaging platform with ultrafast Doppler capability was used. The benchmark was a clinical system with conventional Doppler imaging. Standardized dorsal long-axis scanning of both wrists was performed. Both ultrafast and conventional power Doppler (PD) images were quantitatively analyzed with computer assistance and semiquantitatively scored with the Outcome Measures in Rheumatology (OMERACT) scoring system. RESULTS: Ultrafast PD revealed more blood area than conventional PD in both RA wrists and healthy wrists. Ultrafast PD OMERACT was positive in 65 of 66 RA wrists and 26 of 30 healthy wrists (sensitivity [SEN] = 0.985, accuracy [ACC] = 0.719), while conventional PD OMERACT was positive in 28 of 66 RA wrists and 0 of 30 healthy wrists (SEN = 0.424, ACC = 0.604). Ultrafast PD revealed a higher synovial PD area, dilated vessels and PD brightness in RA wrists. Peak synovial PD brightness had the best diagnostic value for RA (area under the receiver operating characteristic curve = 0.802, SEN = 0.909, ACC = 0.813). For early-stage RA patients, ultrafast peak synovial PD brightness had higher sensitivity and accuracy than conventional PD indexes. CONCLUSION: Ultrafast PD had an increase of 0.561 in sensitivity and 0.209 in accuracy when compared with conventional PD. With its high sensitivity, ultrafast PD can detect early synovitis and identify RA patients during the early phase.


Subject(s)
Arthritis, Rheumatoid , Synovitis , Humans , Arthritis, Rheumatoid/complications , Arthritis, Rheumatoid/diagnostic imaging , Ultrasonography, Doppler/methods , Synovitis/complications , Synovitis/diagnostic imaging , Ultrasonography/methods , ROC Curve
6.
Cardiovasc Eng Technol ; 15(1): 65-76, 2024 02.
Article in English | MEDLINE | ID: mdl-37962814

ABSTRACT

PURPOSE: Wall shear stress (WSS) is a critically important physical factor contributing to atherosclerosis. Mapping the spatial distribution of local, oscillatory WSS can identify important mechanisms underlying the progression of coronary artery disease. METHODS: In this study, blood flow velocity and time-varying WSS were estimated in the left anterior descending (LAD) coronary artery of an ex vivo beating porcine heart using ultrasound with an 18 MHz linear array transducer aligned with the LAD in a forward-viewing orientation. A pulsatile heart loop with physiologically-accurate flow was created using a pulsatile pump. The coronary artery wall motion was compensated using a local block matching technique. Next, 2D and 3D velocity magnitude and WSS maps in the LAD coronary artery were estimated at different time points in the cardiac cycle using an ultrafast Doppler approach. The blood flow velocity estimated using the presented approach was compared with a commercially-available, calibrated single element blood flow velocity measurement system. RESULTS: The resulting root mean square error (RMSE) of 2D velocity magnitude acquired from a high frequency, linear array transducer was less than 8% of the maximum velocity estimated by the commercial system. CONCLUSION: When implemented in a forward-viewing intravascular ultrasound device, the presented approach will enable dynamic estimation of WSS, an indicator of plaque vulnerability in coronary arteries.


Subject(s)
Coronary Artery Disease , Plaque, Atherosclerotic , Animals , Swine , Blood Flow Velocity , Heart/physiology , Coronary Vessels , Coronary Artery Disease/diagnostic imaging , Stress, Mechanical
7.
J Clin Anesth ; 92: 111312, 2024 02.
Article in English | MEDLINE | ID: mdl-37926064

ABSTRACT

BACKGROUND: Ultrafast cerebral Doppler ultrasound enables simultaneous quantification and visualization of cerebral blood flow velocity. The aim of this study is to compare the use of conventional and ultrafast spectral Doppler during anesthesia and their potential to show the effect of anesthesiologic procedures on cerebral blood flow velocities, in relation to blood pressure and cerebral oxygenation in infants undergoing inguinal hernia repair. METHODS: A single-center prospective observational cohort study in infants up to six months of age. We evaluated conventional and ultrafast spectral Doppler cerebral ultrasound measurements in terms of number of successful measurements during the induction of anesthesia, after sevoflurane induction, administration of caudal analgesia, a fluid bolus and emergence of anesthesia. Cerebral blood flow velocity was quantified in pial arteries using conventional spectral Doppler and in the cerebral cortex using ultrafast Doppler by peak systolic velocity, end diastolic velocity and resistivity index. RESULTS: Twenty infants were included with useable conventional spectral Doppler images in 72/100 measurements and ultrafast Doppler images in 51/100 measurements. Intraoperatively, the success rates were 53/60 (88.3%) and 41/60 (68.3%), respectively. Cerebral blood flow velocity increased after emergence for both conventional (end diastolic velocity, from 2.01 to 2.75 cm/s, p < 0.001) and ultrafast spectral Doppler (end diastolic velocity, from 0.59 to 0.94 cm/s), whereas cerebral oxygenation showed a reverse pattern with a decrease after the emergence of the infant (85% to 68%, p < 0.001). CONCLUSION: It is possible to quantify cortical blood flow velocity during general anesthesia using conventional and ultrafast spectral Doppler cerebral ultrasound. Cerebral blood flow velocity and blood pressure decreased, while regional cerebral oxygenation increased during general anesthesia. Ultrafast spectral Doppler ultrasound offers novel insights into perfusion within the cerebral cortex, unattainable through conventional spectral ultrasound. Yet, ultrafast Doppler is curtailed by a lower success rate and a more rigorous learning curve compared to conventional method.


Subject(s)
Hernia, Inguinal , Ultrasonography, Doppler, Transcranial , Infant , Humans , Prospective Studies , Hernia, Inguinal/surgery , Ultrasonography, Doppler , Blood Flow Velocity , Cerebrovascular Circulation/physiology
8.
Adv Sci (Weinh) ; 10(36): e2303966, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37847902

ABSTRACT

To combat the irreversible decline in renal function associated with kidney disease, it is essential to establish non-invasive biomarkers for assessing renal microcirculation. However, the limited resolution and/or vascular sensitivity of existing diagnostic imaging techniques hinders the visualization of complex cortical vessels. Here, a 3D renal ultrafast Doppler (UFD) imaging system that uses a high ultrasound frequency (18 MHz) and ultrahigh frame rate (1 KHz per slice) to scan the entire volume of a rat's kidney in vivo is demonstrated. The system, which can visualize the full 3D renal vascular branching pyramid at a resolution of 167 µm without any contrast agent, is used to chronically and noninvasively monitor kidneys with acute kidney injury (AKI, 3 days) and diabetic kidney disease (DKD, 8 weeks). Multiparametric UFD analyses (e.g., vessel volume occupancy (VVO), fractional moving blood volume (FMBV), vessel number density (VND), and vessel tortuosity (VT)) describe rapid vascular rarefaction from AKI and long-term vascular degeneration from DKD, while the renal pathogeneses are validated by in vitro blood serum testing and stained histopathology. This work demonstrates the potential of 3D renal UFD to offer valuable insights into assessing kidney perfusion levels for future research in diabetes and kidney transplantation.


Subject(s)
Acute Kidney Injury , Diabetes Mellitus , Diabetic Nephropathies , Rats , Animals , Diabetic Nephropathies/diagnostic imaging , Contrast Media , Kidney/diagnostic imaging , Ultrasonography, Doppler/methods , Acute Kidney Injury/diagnostic imaging
9.
Herz ; 48(5): 339-351, 2023 Oct.
Article in German | MEDLINE | ID: mdl-37530782

ABSTRACT

Continuous developments in cardiovascular imaging, software and hardware have led to technological advancements that open new ways for assessing myocardial mechanics, hemodynamics, and function. Through new scan modalities, echocardiographic scanners can nowadays achieve very high frame rates up to 5000 frames s-1 which enables a wide variety of new applications, including shear wave elastography, ultrafast speckle tracking, the visualization of intracardiac blood flow and myocardial perfusion imaging. This review provides an overview of these advances and demonstrates possible applications and their potential added value in the clinical practice.

10.
World Neurosurg ; 177: 3-4, 2023 May 28.
Article in English | MEDLINE | ID: mdl-37253407

ABSTRACT

Ultrafast ultrasound Doppler imaging offers a new and advantageous intraoperative method for brain lesions. Compared to the conventional color Doppler ultrasound system, the ultrafast Doppler allows us to image hemodynamics in small vasculature in an unprecedented high spatio-temporal resolution without using contrast agent. This report presents an intraoperative ultrafast ultrasound Doppler image of a 53-year-old male with a language eloquent area brain arteriovenous malformation. The advanced ultrafast Doppler method provides the nidus vasculature hemodynamics with a spatial resolution of 300 µm at thousands of framerates per second. The image also demonstrates that no abnormal vessels infiltrated the eloquent gyrus as the piamatral small vessels outlined the intact boundary. Successful removal of the nidus with full language function preservation highlights the potentials of ultrafast Doppler imaging to improve diagnostic capabilities and surgical outcomes for patients with intracranial lesions.

11.
J Cereb Blood Flow Metab ; 43(9): 1557-1570, 2023 09.
Article in English | MEDLINE | ID: mdl-37070356

ABSTRACT

Quantification of vascularization volume can provide valuable information for diagnosis and prognosis in vascular pathologies. It can be adapted to inform the surgical management of gliomas, aggressive brain tumors characterized by exuberant sprouting of new blood vessels (neoangiogenesis). Filtered ultrafast Doppler data can provide two main parameters: vascularization index (VI) and fractional moving blood volume (FMBV) that clinically reflect tumor micro vascularization. Current protocols lack robust, automatic, and repeatable filtering methods. We present a filtrating method called Multi-layered Adaptive Neoangiogenesis Intra-Operative Quantification (MANIOQ). First, an adaptive clutter filtering is implemented, based on singular value decomposition (SVD) and hierarchical clustering. Second a method for noise equalization is applied, based on the subtraction of a weighted noise profile. Finally, an in vivo analysis of the periphery of the B-mode hyper signal area allows to measure the vascular infiltration extent of the brain tumors. Ninety ultrasound acquisitions were processed from 23 patients. Compared to reference methods in the literature, MANIOQ provides a more robust tissue filtering, and noise equalization allows for the first time to keep axial and lateral gain compensation (TGC and LGC). MANIOQ opens the way to an intra-operative clinical analysis of gliomas micro vascularization.


Subject(s)
Brain Neoplasms , Ultrasonography, Doppler , Humans , Blood Flow Velocity/physiology , Phantoms, Imaging , Ultrasonography, Doppler/methods , Ultrasonography , Neovascularization, Pathologic/diagnostic imaging , Brain Neoplasms/diagnostic imaging , Brain Neoplasms/surgery , Image Processing, Computer-Assisted/methods
12.
Front Neurosci ; 16: 1015843, 2022.
Article in English | MEDLINE | ID: mdl-36466181

ABSTRACT

The dynamic vascular responses during cortical spreading depolarization (CSD) are causally related to pathophysiological consequences in numerous neurovascular conditions, including ischemia, traumatic brain injury, cerebral hemorrhage, and migraine. Monitoring of the hemodynamic responses of cerebral penetrating vessels during CSD is motivated to understand the mechanism of CSD and related neurological disorders. Six SD rats were used, and craniotomy surgery was performed before imaging. CSDs were induced by topical KCl application. Ultrasound dynamic ultrafast Doppler was used to access hemodynamic changes, including cerebral blood volume (CBV) and flow velocity during CSD, and further analyzed those in a single penetrating arteriole or venule. The CSD-induced hemodynamic changes with typical duration and propagation speed were detected by ultrafast Doppler in the cerebral cortex ipsilateral to the induction site. The hemodynamics typically showed triphasic changes, including initial hypoperfusion and prominent hyperperfusion peak, followed by a long-period depression in CBV. Moreover, different hemodynamics between individual penetrating arterioles and venules were proposed by quantification of CBV and flow velocity. The negative correlation between the basal CBV and CSD-induced change was also reported in penetrating vessels. These results indicate specific vascular dynamics of cerebral penetrating vessels and possibly different contributions of penetrating arterioles and venules to the CSD-related pathological vascular consequences. We proposed using ultrasound dynamic ultrafast Doppler imaging to investigate CSD-induced cerebral vascular responses. With this imaging platform, it has the potential to monitor the hemodynamics of cortical penetrating vessels during brain injuries to understand the mechanism of CSD in advance.

13.
Ultrasound Med Biol ; 45(5): 1284-1296, 2019 05.
Article in English | MEDLINE | ID: mdl-30799125

ABSTRACT

Angiogenesis, the formation of new vessels, is one of the key mechanisms in tumor development and an appealing target for therapy. Non-invasive, high-resolution, high-sensitivity, quantitative 3-D imaging techniques are required to correctly depict tumor heterogeneous vasculature over time. Ultrafast Doppler was recently introduced and provides an unprecedented combination of resolution, penetration depth and sensitivity without requiring any contrast agents. The technique was further extended to three dimensions with ultrafast Doppler tomography (UFD-T). In this work, UFD-T was applied to the monitoring of tumor angiogenesis in vivo, providing structural and functional information at different stages of development. UFD-T volume renderings revealed that our murine model's vasculature stems from pre-existing vessels and sprouts to perfuse the whole volume as the tumor grows until a critical size is reached. Then, as the network becomes insufficient, the tumor core is no longer irrigated because the vasculature is concentrated mainly in the periphery. In addition to spatial distribution and growth patterns, UFD-T allowed a quantitative analysis of vessel size and length, revealing that the diameter distribution of vessels remained relatively constant throughout tumor growth. The network is dominated by small vessels at all stages of tumor development, with more than 74% of the vessels less than 200 µm in diameter. This study also found that cumulative vessel length is more closely related to tumor radius than volume, indicating that the vascularization becomes insufficient when a critical mass is reached. UFD-T was also compared with dynamic contrast-enhanced ultrasound and found to provide complementary information regarding the link between structure and perfusion. In conclusion, UFD-T is capable of in vivo quantitative assessment of the development of tumor vasculature (vessels with blood speed >1 mm/s [sensitivity limit] assessed with a resolution limit of 80 µm) in 3 dimensions. The technique has very interesting potential as a tool for treatment monitoring, response assessment and treatment planning for optimal drug efficiency.


Subject(s)
Imaging, Three-Dimensional/methods , Neoplasms/blood supply , Neoplasms/diagnostic imaging , Neovascularization, Pathologic/diagnostic imaging , Tomography, X-Ray Computed/methods , Ultrasonography, Doppler/methods , Animals , Disease Models, Animal , Mice , Multimodal Imaging/methods
14.
Neuroimage ; 183: 469-477, 2018 12.
Article in English | MEDLINE | ID: mdl-30118869

ABSTRACT

Recent advances in ultrasound Doppler imaging have facilitated the technique of functional ultrasound (fUS) which enables visualization of brain-activity due to neurovascular coupling. As of yet, this technique has been applied to rodents as well as to human subjects during awake craniotomy surgery and human newborns. Here we demonstrate the first successful fUS studies on awake pigeons subjected to auditory and visual stimulation. To allow successful fUS on pigeons we improved the temporal resolution of fUS up to 20,000 frames per second with real-time visualization and continuous recording. We show that this gain in temporal resolution significantly increases the sensitivity for detecting small fluctuations in cerebral blood flow and volume which may reflect increased local neural activity. Through this increased sensitivity we were able to capture the elaborate 3D neural activity pattern evoked by a complex stimulation pattern, such as a moving light source. By pushing the limits of fUS further, we have reaffirmed the enormous potential of this technique as a new standard in functional brain imaging with the capacity to unravel unknown, stimulus related hemodynamics with excellent spatiotemporal resolution with a wide field of view.


Subject(s)
Auditory Perception/physiology , Brain/physiology , Columbidae/physiology , Functional Neuroimaging/methods , Imaging, Three-Dimensional/methods , Neurovascular Coupling/physiology , Ultrasonography, Doppler/methods , Visual Perception/physiology , Animals , Brain/diagnostic imaging , Female , Image Processing, Computer-Assisted/methods , Male
15.
Neuroimage ; 127: 472-483, 2016 Feb 15.
Article in English | MEDLINE | ID: mdl-26555279

ABSTRACT

4D ultrasound microvascular imaging was demonstrated by applying ultrafast Doppler tomography (UFD-T) to the imaging of brain hemodynamics in rodents. In vivo real-time imaging of the rat brain was performed using ultrasonic plane wave transmissions at very high frame rates (18,000 frames per second). Such ultrafast frame rates allow for highly sensitive and wide-field-of-view 2D Doppler imaging of blood vessels far beyond conventional ultrasonography. Voxel anisotropy (100 µm × 100 µm × 500 µm) was corrected for by using a tomographic approach, which consisted of ultrafast acquisitions repeated for different imaging plane orientations over multiple cardiac cycles. UFT-D allows for 4D dynamic microvascular imaging of deep-seated vasculature (up to 20 mm) with a very high 4D resolution (respectively 100 µm × 100 µm × 100 µm and 10 ms) and high sensitivity to flow in small vessels (>1 mm/s) for a whole-brain imaging technique without requiring any contrast agent. 4D ultrasound microvascular imaging in vivo could become a valuable tool for the study of brain hemodynamics, such as cerebral flow autoregulation or vascular remodeling after ischemic stroke recovery, and, more generally, tumor vasculature response to therapeutic treatment.


Subject(s)
Brain/blood supply , Neuroimaging/methods , Ultrasonography, Doppler/methods , Animals , Image Processing, Computer-Assisted , Imaging, Three-Dimensional/methods , Rats , Rats, Sprague-Dawley , Tomography, X-Ray Computed
16.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-497951

ABSTRACT

Objective To analyze the accuracy,repeatability and feasibility of Ultrafast Doppler for renal artery ultrasonography.Methods One hundred and one cases were selected that were suspected to have renal artery disease and were successful of conventional and Ultrafast Doppler for renal artery ultrasonography,and 101 cases were grouped by age (≤40 years old,41-60 years old,≥61 years old),body mass index (BMI) (normal 18.5-23.9 kg/m2,overweight 24.0-27.9 kg/m2,obesity ≥28.0kg/m2) and whether there were the presence of renal artery stenosis (no significant renal artery stenosis and renal artery stenosis >60%).Each case was respectively examined by conventional and Ultrafast Doppler for renal artery ultrasonography in a random order.The consistency of Doppler parameters was tested.The duration of each Doppler study was compared and the feasibility of Ultrafast Doppler for renal artery ultrasonography was explored.The Doppler parameters included:renal artery peak systolic velocity (PSV),resistance index (RI),renal segmental artery acceleration time (T) and time consuming (△T).The concordence and △T of two Doppler method were compared.Results ① Ultrafast Doppler had good reproducibility,intraclass correlation coefficient (ICC) values were > 0.6.② For renal artery ultrasonography,the successful number of cases examined by Ultrafast Doppler were more than those examined by conventional Doppler,but the difference was not statistically significant (P >0.05).③The Doppler parameters from all subjects and different groups showed a strong positive correlation between the two Doppler studies (P <0.05).④ UltraFast Doppler required a shorter time than conventional Doppler (P <0.05).⑤The △T of cases with different ages and with or without renal artery stenosis showed no statistically significant (P >0.05),however,their △T were increased with body mass index increasing (P<0.05).Conclusions Ultrafast Doppler for renal artery ultrasonography has a high success rate,a good repeatability and consistency,and a shorter time consuming and simple operation than conventional Doppler.