Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 65.769
Filter
1.
Article in English | MEDLINE | ID: mdl-38694539

ABSTRACT

Objective: This study aimed to investigate the usefulness of endoscopic ultrasound-guided tissue acquisition (EUS-TA) for diagnosing focal liver lesions in patients with a history of multiple primary malignant neoplasms. Methods: Among patients who underwent EUS-TA for focal liver lesions between 2016 and 2022, those with a history of multiple malignant neoplasms were included. A histologically confirmed malignant tumor within the past 5 years before EUS-TA was defined as a history of malignant neoplasm. The primary outcomes were diagnostic ability and adverse events of EUS-TA. Results: This study included 16 patients (median age, 73 [33-90] years), the median tumor size was 32 (6-51) mm, 14 had a history of double malignant neoplasms, whereas two had triple malignant neoplasms. Malignant neoplasms were detected histologically or cytologically in all cases. Immunohistochemistry was performed in 75% (12/16), and the final diagnosis of EUS-TA was metastatic liver tumor in 12 patients, and primary malignant liver tumor in four patients. The primary site could be identified in 11 of 12 metastatic tumor cases. The diagnostic yield of EUS-TA was 100% (16/16) for differentiating benign and malignant tumors and 94% (15/16) for confirming the histological type including the primary site of metastatic lesions. No adverse events were associated with the procedure. Conclusion: EUS-TA is a useful diagnostic modality for focal liver lesions in patients with a history of multiple malignant neoplasms, allowing for the differential diagnosis of primary and metastatic tumors and identification of the primary site of metastatic lesions.

2.
Article in English | MEDLINE | ID: mdl-38817688

ABSTRACT

Gossypiboma is an extremely rare adverse event occurring post-surgery, where surgical gauze is left within the body. If aseptically retained, it can lead to the formation of granulation tissue through chronic inflammation and adhesion with surrounding tissues, potentially persisting asymptomatically for many years. While diagnosis of this condition has been reported through various imaging modalities such as abdominal ultrasound and computed tomography, cases not presenting with typical findings are difficult for preoperative diagnosis, and instances where it is discovered postoperatively exist. Particularly when in contact with the gastrointestinal tract within the abdominal cavity, differentiation from submucosal tumors of the digestive tract becomes problematic. This report describes the imaging characteristics of endoscopic ultrasound and the usefulness of endoscopic ultrasound-fine-needle-aspiration for tissue diagnosis in the preoperative diagnosis of intra-abdominal gossypiboma.

3.
Article in English | MEDLINE | ID: mdl-38715895

ABSTRACT

Objectives: To identify and classify submucosal tumors by building and validating a radiomics model with gastrointestinal endoscopic ultrasonography (EUS) images. Methods: A total of 144 patients diagnosed with submucosal tumors through gastrointestinal EUS were collected between January 2019 and October 2020. There are 1952 radiomic features extracted from each patient's EUS images. The statistical test and the customized least absolute shrinkage and selection operator regression were used for feature selection. Subsequently, an extremely randomized trees algorithm was utilized to construct a robust radiomics classification model specifically tailored for gastrointestinal EUS images. The performance of the model was measured by evaluating the area under the receiver operating characteristic curve. Results: The radiomics model comprised 30 selected features that showed good discrimination performance in the validation cohorts. During validation, the area under the receiver operating characteristic curve was calculated as 0.9203 and the mean value after 10-fold cross-validation was 0.9260, indicating excellent stability and calibration. These results confirm the clinical utility of the model. Conclusions: Utilizing the dataset provided curated from gastrointestinal EUS examinations at our collaborating hospital, we have developed a well-performing radiomics model. It can be used for personalized and non-invasive prediction of the type of submucosal tumors, providing physicians with aid for early treatment and management of tumor progression.

4.
Front Neurosci ; 18: 1420255, 2024.
Article in English | MEDLINE | ID: mdl-38962179

ABSTRACT

Unmatched by other non-invasive brain stimulation techniques, transcranial ultrasound (TUS) offers highly focal stimulation not only on the cortical surface but also in deep brain structures. These unique attributes are invaluable in both basic and clinical research and might open new avenues for treating neurological and psychiatric diseases. Here, we provide a concise overview of the expanding volume of clinical investigations in recent years and upcoming research initiatives concerning focused ultrasound neuromodulation. Currently, clinical TUS research addresses a variety of neuropsychiatric conditions, such as pain, dementia, movement disorders, psychiatric conditions, epilepsy, disorders of consciousness, and developmental disorders. As demonstrated in sham-controlled randomized studies, TUS neuromodulation improved cognitive functions and mood, and alleviated symptoms in schizophrenia and autism. Further, preliminary uncontrolled evidence suggests relieved anxiety, enhanced motor functions in movement disorders, reduced epileptic seizure frequency, improved responsiveness in patients with minimally conscious state, as well as pain reduction after neuromodulatory TUS. While constrained by the relatively modest number of investigations, primarily consisting of uncontrolled feasibility trials with small sample sizes, TUS holds encouraging prospects for treating neuropsychiatric disorders. Larger sham-controlled randomized trials, alongside further basic research into the mechanisms of action and optimal sonication parameters, are inevitably needed to unfold the full potential of TUS neuromodulation.

5.
Front Oncol ; 14: 1288041, 2024.
Article in English | MEDLINE | ID: mdl-38962263

ABSTRACT

Background: Small Bowel Adenocarcinoma (SBA) is rare, occult and life-threatening malignancy in digestive system. Given low incidence and nonspecific symptoms, SBA is frequently detected in later stages. Double contrast enhanced ultrasound (DCEUS) is an innovative imaging technique applied to visualize the gastrointestinal tract, merging intravenous contrast-enhanced ultrasound with oral contrast-enhanced ultrasound. In this case, DCEUS was utilized and successfully detected an SBA of the jejunum. Case presentation: A Chinese woman, aged 64, sought consultation in the gastroenterology department at our hospital, reporting symptoms of abdominal pain. Three months before entering the hospital, she underwent gastroscopy and colonoscopy which suggested chronic gastritis, and she was treated with oral drugs. However, her symptoms were not relieved, and even worsened. To further investigate, DCEUS was performed. The oral contrast agent dilated the luminal space of the upper gastrointestinal tract, resolving the hindrance caused by gas in the gastrointestinal tract and creating an acoustic window for scanning. Through this acoustic window, oral agent contrast-enhanced ultrasound (OA-CEUS) revealed a localized thickening of jejunal intestinal wall measuring 4x3 cm. Following intravenous injection of ultrasound contrast agent, the jejunal lesion exhibited faster enhancement and heterogeneous hyper-enhancement. Finally, the patient underwent jejunal tumor resection. Pathological examination revealed a jejunal adenocarcinoma. Conclusion: The timely diagnosis of SBA can be challenging. DCEUS may have the potential to contribute to diagnosis and detailed evaluation of SBA, particularly in cases involving jejunum. Further researches are needed to fully explore the benefits of DCEUS in the standard diagnostic approach for small bowel diseases.

6.
Front Mol Biosci ; 11: 1408767, 2024.
Article in English | MEDLINE | ID: mdl-38962281

ABSTRACT

Targeted delivery of medication has the promise of increasing the effectiveness and safety of current systemic drug treatments. Focused ultrasound is emerging as noninvasive and practical energy for targeted drug release. However, it has yet to be determined which nanocarriers and ultrasound parameters can provide both effective and safe release. Perfluorocarbon nanodroplets have the potential to achieve these goals, but current approaches have either been effective or safe, but not both. We found that nanocarriers with highly stable perfluorocarbon cores mediate effective drug release so long as they are activated by ultrasound of sufficiently low frequency. We demonstrate a favorable safety profile of this formulation in a non-human primate. To facilitate translation of this approach into humans, we provide an optimized method for manufacturing the nanocarriers. This study provides a recipe and release parameters for effective and safe drug release from nanoparticle carriers in the body part specified by focused ultrasonic waves.

7.
Nagoya J Med Sci ; 86(2): 189-200, 2024 May.
Article in English | MEDLINE | ID: mdl-38962413

ABSTRACT

Patients with acute coronary syndrome (ACS), frequently caused by plaque rupture (PR), often have vulnerable plaques in residual lesions as well as in culprit lesions. However, whether this occurs in patients with plaque erosion (PE) as well is unknown. We retrospectively analyzed the data of 88 patients with ACS who underwent both optimal coherence tomography (OCT) and intravascular ultrasound (IVUS). Based on plaque morphology of the culprit lesions identified using OCT, patients were classified into PE (n=23) and PR (n=35) groups. The tissue characteristics of residual lesions evaluated using integrated backscatter IVUS were compared between both groups after percutaneous coronary intervention. The PE group had a significantly lower percent lipid volume and a higher percent fibrous volume than the PR group (35.0±17.8% vs 49.2±13.4%, p<0.001; 63.2±17.1% vs 50.3±13.1%, p=0.002, respectively). Receiver operating characteristic curve analysis revealed that percent lipid volume in the residual lesions was a significant discriminant factor in estimating the plaque morphology of the culprit lesion (optimal cut-off value, <43.5%; sensitivity and specificity values were 73.9% and 68.6%, respectively). In conclusion, patients with PE had a significantly lower percent lipid volume and a significantly higher percent fibrous volume in the residual lesions than those with PR, suggesting that the nature of coronary plaques in patients with PE is different from that of those with PR.


Subject(s)
Acute Coronary Syndrome , Plaque, Atherosclerotic , Tomography, Optical Coherence , Ultrasonography, Interventional , Humans , Acute Coronary Syndrome/diagnostic imaging , Acute Coronary Syndrome/pathology , Retrospective Studies , Male , Female , Plaque, Atherosclerotic/diagnostic imaging , Plaque, Atherosclerotic/pathology , Middle Aged , Aged , Ultrasonography, Interventional/methods , Tomography, Optical Coherence/methods , Percutaneous Coronary Intervention , Rupture, Spontaneous , ROC Curve , Coronary Vessels/diagnostic imaging , Coronary Vessels/pathology
8.
Cureus ; 16(6): e61606, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38962619

ABSTRACT

We present the case of a 56-year-old female with a significant medical history of cholelithiasis and recurrent choledocholithiasis. Following an elective cholecystectomy, an obstructing gallstone in the common bile duct led to a series of interventions, including endoscopic retrograde cholangiopancreatography and stent placement. The patient was scheduled for a robot-assisted laparoscopic common bile duct exploration. Due to severe adhesions, the procedure was converted to open with a large right upper quadrant incision. Intraoperative continuous external oblique block and catheter placement were performed at the end of surgery in the OR. Peripheral nerve blocks have become an integral part of multimodal pain management strategies. This case report describes the successful implementation of an ultrasound-guided right external oblique intercostal block and catheter placement for postoperative pain control and minimization of opioids. This case highlights the efficacy and safety of ultrasound-guided peripheral nerve blocks for postoperative pain management. Successful pain control contributed to the patient's overall postoperative recovery.

9.
Cureus ; 16(6): e61596, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38962628

ABSTRACT

Pain management is often difficult in the setting of multi-site trauma such as that caused by motor vehicle accidents (MVA), which is especially compounded in the setting of polysubstance abuse. This often results in patients with poor pain tolerance requiring escalating doses of opioid therapy, which creates a vicious cycle. The use of peripheral nerve blocks (PNB) has been shown to decrease overall opioid consumption and can be used effectively to manage postoperative pain in this patient population. Our case report aims to highlight the importance of PNBs as part of a multimodal approach to pain management in patients with polytrauma in the setting of polysubstance abuse.

10.
J Med Internet Res ; 26: e51397, 2024 Jul 04.
Article in English | MEDLINE | ID: mdl-38963923

ABSTRACT

BACKGROUND: Machine learning (ML) models can yield faster and more accurate medical diagnoses; however, developing ML models is limited by a lack of high-quality labeled training data. Crowdsourced labeling is a potential solution but can be constrained by concerns about label quality. OBJECTIVE: This study aims to examine whether a gamified crowdsourcing platform with continuous performance assessment, user feedback, and performance-based incentives could produce expert-quality labels on medical imaging data. METHODS: In this diagnostic comparison study, 2384 lung ultrasound clips were retrospectively collected from 203 emergency department patients. A total of 6 lung ultrasound experts classified 393 of these clips as having no B-lines, one or more discrete B-lines, or confluent B-lines to create 2 sets of reference standard data sets (195 training clips and 198 test clips). Sets were respectively used to (1) train users on a gamified crowdsourcing platform and (2) compare the concordance of the resulting crowd labels to the concordance of individual experts to reference standards. Crowd opinions were sourced from DiagnosUs (Centaur Labs) iOS app users over 8 days, filtered based on past performance, aggregated using majority rule, and analyzed for label concordance compared with a hold-out test set of expert-labeled clips. The primary outcome was comparing the labeling concordance of collated crowd opinions to trained experts in classifying B-lines on lung ultrasound clips. RESULTS: Our clinical data set included patients with a mean age of 60.0 (SD 19.0) years; 105 (51.7%) patients were female and 114 (56.1%) patients were White. Over the 195 training clips, the expert-consensus label distribution was 114 (58%) no B-lines, 56 (29%) discrete B-lines, and 25 (13%) confluent B-lines. Over the 198 test clips, expert-consensus label distribution was 138 (70%) no B-lines, 36 (18%) discrete B-lines, and 24 (12%) confluent B-lines. In total, 99,238 opinions were collected from 426 unique users. On a test set of 198 clips, the mean labeling concordance of individual experts relative to the reference standard was 85.0% (SE 2.0), compared with 87.9% crowdsourced label concordance (P=.15). When individual experts' opinions were compared with reference standard labels created by majority vote excluding their own opinion, crowd concordance was higher than the mean concordance of individual experts to reference standards (87.4% vs 80.8%, SE 1.6 for expert concordance; P<.001). Clips with discrete B-lines had the most disagreement from both the crowd consensus and individual experts with the expert consensus. Using randomly sampled subsets of crowd opinions, 7 quality-filtered opinions were sufficient to achieve near the maximum crowd concordance. CONCLUSIONS: Crowdsourced labels for B-line classification on lung ultrasound clips via a gamified approach achieved expert-level accuracy. This suggests a strategic role for gamified crowdsourcing in efficiently generating labeled image data sets for training ML systems.


Subject(s)
Crowdsourcing , Lung , Ultrasonography , Crowdsourcing/methods , Humans , Ultrasonography/methods , Ultrasonography/standards , Lung/diagnostic imaging , Prospective Studies , Female , Male , Machine Learning , Adult , Middle Aged , Retrospective Studies
11.
Braz J Phys Ther ; 28(4): 101092, 2024 Jun 16.
Article in English | MEDLINE | ID: mdl-38964202

ABSTRACT

BACKGROUND: Technological running shoes have become increasingly popular, leading to improvements in performance. However, their long-term effects on foot musculature and joint mobility have not been thoroughly studied. OBJECTIVE: To compare the activation of the intrinsic foot muscles between runners wearing technological footwear and barefoot runners. Secondary objectives included assessing ankle dorsiflexion (DF) range of motion (ROM) and dynamic postural control in both groups. METHODS: A cross-sectional study was conducted involving 22 technological footwear runners and 22 barefoot runners. Ultrasonography was used to measure the thickness of the plantar fascia (PF) and the quadratus plantae (QP), abductor digiti minimus (ADM), abductor hallucis (AH), and flexor hallucis longus (FHL) muscles. Ankle mobility and dynamic postural control were also recorded. RESULTS: Ultrasonography measurements showed statistically significant differences for PF thickness (mean difference [MD]: -0.10 cm; 95% CI: -0.13, -0.05 cm), QP cross-sectional area (CSA) (MD: -0.45 cm2; 95% CI: -0.77, -0.12 cm2), ADM CSA (MD: -0.49 cm2; 95% CI: -0.70, -0.17 cm2), and FHL thickness (MD: 0.82 cm; 95% CI: 0.53, 1.09 cm), with all measurements being lower in the group wearing technological footwear compared to the barefoot runners. Ankle DF ROM was also significantly greater for the barefoot runners (MD: -5.1°; 95% CI: -8.6, -1.7°). CONCLUSIONS: These findings suggest potential implications for the foot musculature and ankle mobility in runners using technological footwear.

12.
Hum Reprod ; 2024 Jul 04.
Article in English | MEDLINE | ID: mdl-38964365

ABSTRACT

STUDY QUESTION: What is the prevalence of congenital and acquired anomalies of the uterus in women with recurrent pregnancy loss (RPL) of unknown etiology examined using 3D transvaginal ultrasound (US)? SUMMARY ANSWER: Depending on the adopted diagnostic criteria, the prevalence of partial septate uterus varies between 7% and 14% and a T-shaped uterus is 3% or 4%, while adenomyosis is 23%, at least one of type 0, type 1 or type 2 myoma is 4%, and at least one endometrial polyp is 4%. WHAT IS KNOWN ALREADY: ESHRE and the Royal College of Obstetricians and Gynaecologists guidelines on RPL recommend the adoption of the 3D transvaginal US to evaluate the 'uterine factor'. Nevertheless, there are no published studies reporting the prevalence of both congenital and acquired uterine anomalies as assessed by 3D transvaginal US and diagnosed according to the criteria proposed by the most authoritative panels of experts in a cohort of women with RPL. STUDY DESIGN, SIZE, DURATION: This was a retrospective cohort study including 442 women with at least two previous first-trimester spontaneous pregnancy losses (i.e. non-viable intrauterine pregnancies), who referred to the obstetrics and gynecology unit of two university hospitals between July 2020 and July 2023. PARTICIPANTS/MATERIALS, SETTING, METHODS: Records of eligible women were reviewed. Women could be included in the study if: they were between 25 and 42 years old; they had no relevant comorbidities; they were not affected by infertility, and they had never undergone ART; they and their partner tested negative to a comprehensive RPL diagnostic work-up; and they had never undergone metroplasty, myomectomy, minimally invasive treatments for uterine fibroids or adenomyomectomy. Expert sonographers independently re-analyzed the stored 2- and 3D transvaginal US images of all included patients. Congenital uterine anomalies (CUAs) were reported according to the American Society for Reproductive Medicine (ASRM) 2021, the ESHRE/European Society for Gynaecological Endoscopy (ESGE) and the Congenital Uterine Malformation by Experts (CUME) criteria. Acquired uterine anomalies were reported according to the International Federation of Gynecology and Obstetrics (FIGO) and the Morphological Uterus Sonographic Assessment (MUSA) criteria. MAIN RESULTS AND THE ROLE OF CHANCE: The partial septate uterus was diagnosed in 60 (14%; 95% CI: 11-17%), 29 (7%; 95% CI: 5-9%), and 47 (11%; 95% CI: 8-14%) subjects, according to the ESHRE/ESGE, the ASRM 2021, and the CUME criteria, respectively. The T-shaped uterus was diagnosed in 19 women (4%; 95% CI: 3-7%) according to the ESHRE/ESGE criteria and in 13 women (3%; 95% CI: 2-5%) according to the CUME criteria. The borderline T-shaped uterus (diagnosed when two out of three CUME criteria for T-shaped uterus were met) was observed in 16 women (4%; 95% CI: 2-6%). At least one of FIGO type 0, type 1, or type 2 myoma was detected in 4% of included subjects (95% CI: 3-6%). Adenomyosis was detected in 100 women (23%; 95% CI: 19-27%) and was significantly more prevalent in women with primary RPL and in those with three or more pregnancy losses. At least one endometrial polyp was detected in 4% of enrolled women (95% CI: 3-7%). LIMITATIONS, REASONS FOR CAUTION: The absence of a control group prevented us from investigating the presence of an association between both congenital and acquired uterine anomalies and RPL. Second, the presence as well as the absence of both congenital and acquired uterine anomalies detected by 3D US was not confirmed by hysteroscopy. Finally, the results of the present study inevitably suffer from the intrinsic limitations of the adopted classification systems. WIDER IMPLICATIONS OF THE FINDINGS: The prevalence of CUAs in women with RPL varies depending on the classification system used. For reasons of clarity, the US reports should always state the name of the uterine anomaly as well as the adopted classification and diagnostic criteria. Adenomyosis seems to be associated with more severe forms of RPL. The prevalence rates estimated by our study as well as the replicability of the adopted diagnostic criteria provide a basis for the design and sample size calculation of prospective studies. STUDY FUNDING/COMPETING INTEREST(S): No specific funding was used. The authors have no conflicts of interest to declare. TRIAL REGISTRATION NUMBER: N/A.

13.
Ann Vasc Surg ; 2024 Jul 02.
Article in English | MEDLINE | ID: mdl-38964443

ABSTRACT

OBJECTIVE: To present the value of intravascular ultrasound (IVUS) in diagnosis and treatment of complicated type B aortic dissection (TBD) with malperfusion (MP). Especially the value of IVUS regarding the treatment strategy, reoperation rate, acute kidney injury (AKI) and false lumen thrombosis (FLT) was investigated. METHODS: Retrospective analysis of 25 TBD cases with MP treated with endovascular therapy from April 2019 to August 2022. In 17 cases angiography & IVUS were applied during the operation (IVUS group) and in 8 cases angiography was used without IVUS (control group) for final intraoperative control. IVUS was used to assess the true lumen collapse and to decide if additional bare stenting was necessary or not. Details from patients' charts and documentation from surgeries were analyzed. The endovascular technique included thoracic endovascular aortic repair (TEVAR) with primary entry sealing and -if needed- bare stenting of the true lumen distal of the entry tears using the PETTICOAT (Provisional Extension To Induce Complete Attachment) technique. RESULTS: All patients presented with pain localized mostly (48%) in thorax and abdomen. In all patients the proximal entry tear of the dissection was covered using TEVAR. The PETTICOAT technique was applied in 13 cases (52%), whereas most combined procedures were applied in the IVUS group (12 compared to 1; p=0,02). A total of 3 patients (1 in the control group; 12,5% and 2 in the IVUS group; 11,8%) underwent a bowel resection. Totally 8 patients (32%) underwent a reoperation in aorta (3 during the hospital stay). There were no statistical differences between IVUS and control group regarding the preoperative findings, the reoperation rates and the postoperative complications. 5 patients died (4 during the hospital stay), 1 in control and 4 in IVUS group; p=0,53. The follow up included a clinical and a computed tomography angiography (CTA) examination. No statistically significant difference regarding occurrence and extension of FLT was observed between the two groups. CONCLUSIONS: The IVUS and control groups showed no difference in survival rates. The use of IVUS extended the indication for PETTICOAT technique with statistically significant difference. A milder form of AKI presented in the IVUS group compared to the control group. In addition, a stronger correlation between IVUS and the avoidance of an aorta reoperation was observed, though it did not reach statistical significance.

14.
Clin Exp Ophthalmol ; 2024 Jul 04.
Article in English | MEDLINE | ID: mdl-38964827

ABSTRACT

BACKGROUND: A high-frequency point-of-care (POC) ultrasound instrument was used to evaluate the microstructural and biomechanical properties of the anterior sclera in vivo using parameters computed from quantitative ultrasound (QUS) methods. METHODS: In this cross-sectional study, both eyes of 85 enrolled patients were scanned with the POC instrument and ultrasound data were processed to obtain QUS parameters. Pearson correlation and multi-linear regression were used to identify relationships between QUS parameters and refractive error (RE) or axial length. After categorising eyes based on RE, binary support vector machine (SVM) classifiers were trained using the QUS or ophthalmic parameters (anterior chamber depth, central corneal thickness, corneal power, and intraocular pressure) to classify each eye. Classifier performance was evaluated by computing the area under the receiver-operating characteristic curve (AUC). RESULTS: Individual QUS parameters correlated with RE and axial length (p < 0.05). Multi-linear regression revealed significant correlation between the set of QUS parameters and both RE (R = 0.49, p < 0.001) and axial length (R = 0.46, p = 0.001). Classifiers trained with QUS parameters achieved higher AUC (𝑝 = 0.06) for identifying myopic eyes (AUC = 0.71) compared to classifiers trained with ophthalmic parameters (AUC = 0.63). QUS-based classifiers attained the highest AUC when identifying highly myopic eyes (AUC = 0.77). CONCLUSIONS: QUS parameters correlate with progressing myopia and may be indicative of myopia-induced microstructural and biomechanical changes in the anterior sclera. These methods may provide critical clinical information complementary to standard ophthalmic measurements for predicting myopia progression and risk assessment for posterior staphyloma formation.

15.
Hemodial Int ; 2024 Jul 04.
Article in English | MEDLINE | ID: mdl-38965069

ABSTRACT

INTRODUCTION: Optimization of ultrafiltration during hemodialysis is a critical parameter in achieving therapeutic efficacy and ensuring hemodynamic stability. While various modalities such as blood volume monitoring, inferior vena cava diameter assessment, natriuretic peptide levels, bioimpedance assay, and lung ultrasound have been widely explored in the context of maintenance hemodialysis, the concept of volume-guided ultrafiltration in dialysis patients with acute kidney injury remains unexplored. METHODS: Adult patients with acute kidney injury requiring dialysis, who were hemodynamically stable and not on ventilator support, without underlying lung pathology or cardiac failure, were randomized into two groups. All patients underwent 28-zone lung ultrasound before dialysis. The ultrafiltration was decided based on the treating physician's clinical judgment in controls. In the intervention group, the ultrafiltration orders prescribed by the treating physician were modified, based on the Kerley B line scores obtained by lung ultrasound. The rest of the dialysis prescriptions were similar. A postdialysis lung ultrasound was done in both groups to assess the postdialysis volume status 30 min after the dialysis session. RESULTS: A total of 74 patients undergoing hemodialysis for acute kidney injury were randomized. The baseline characteristics were comparable except for higher baseline B line score scores in the intervention arm. All patients received similar dialysis prescriptions. The lung ultrasound-guided ultrafiltration arm had a higher change in B line scores (BLS) from baseline (4 [0-9.5] vs. 0 [0-4]; p value 0.004) during the first dialysis session. The predialysis BLS indexed to ultrafiltration (mL/kbw/h) were significantly lower in controls, reflecting a relatively higher rate of ultrafiltration in controls compared with intervention (p = 0.006). The total number of dialysis sessions done in the control and intervention arm were 61 and 59, respectively. Among controls, 23/61 sessions (37.7%) had intradialytic adverse events, whereas, in the intervention arm, only 4/59 sessions (6.7) had any adverse intradialytic events (p < 0.01). CONCLUSION: Lung ultrasound-guided ultrafiltration was associated with a better safety profile, as demonstrated by reduced intradialytic events.

16.
Obes Surg ; 2024 Jul 04.
Article in English | MEDLINE | ID: mdl-38965187

ABSTRACT

Obesity is a complex disease process, which often requires multifactorial, patient-tailored strategies for effective management. Treatment options include lifestyle optimization, pharmacotherapy, endobariatrics, and bariatric metabolic endoscopy. Obesity-based interventions can be challenging in patient populations with severe obesity, particularly post-gastric bypass. We report the case of a non-surgical patient with a failed remote open gastric bypass, who underwent an endoscopic small bowel diversion procedure, resulting in partial caloric diversion, via the creation of an EUS-guided jejunocolostomy (EUS-JC). The procedure is an extension of prior reported EUS-guided and magnet-based small bowel bypass procedures, in this case, for the purposes of weight loss (Kahaleh et al., 1; Jonica et al. Gastrointest Endosc. 97(5):927-933, 2; Machytka et al. Gastrointest Endosc. 86(5):904-912, 3;). The procedure was performed without peri-procedural complications, with effective weight loss during follow-up. Endoscopic bariatric interventions that target the small bowel, such as EUS-JC, offer promising tools for obesity management and should be studied further. Numerous factors including lifestyle, psychosocial, genetic, behavioral, and secondary disease processes contribute to obesity. Severe obesity (defined as a BMI > 50 kg/m2) is associated with increased morbidity and mortality with a significantly reduced response to treatment (Flegal et al. JAMA. 309(1):71-82, 4;). Weight regain can be noted in up to 50% of patients post-RYGB. In populations with severe obesity, there is an associated 5-year surgical failure rate of 18% (Magro et al. Obesity Surg. 18(6):648-51, 5;). These patients may not be surgical candidates for revision or can develop post-revision chronic protein-caloric malnutrition (Shin et al. Obes Surg. 29(3):811-818, 6;). Lifestyle, modification, pharmacotherapy, or endoscopic transoral reduction (TORe) can be effective generally; however, in patients with severe obesity, the total desired excess body weight loss may not likely be accomplished solely by these strategies. An endoscopic small bowel intervention that diverts a portion of caloric intake from small bowel absorption can potentially promote weight loss similar to a surgical lengthening of the Roux limb (Shah et al. Obes Surg. 33(1):293-302, 7; Hamed et al. Annal Surg. 274(2):271-280, 8;), in the sense that there is a reduction in the total small bowel surface area for absorption. Roux limb distalization can be effective for weight regain for post bypass patients. The EUS-JC technique aims to work similarly by reducing the total small bowel surface area utilized for absorption. Since this patient was deemed a non-surgical candidate, an EUS-guided jejunocolostomy was offered. Prior to the procedure, the patient established longitudinal care with our bariatric nutritionist and obesity medicine services. Extensive pre-bariatric labs were screened to rule out confounders for recurrent severe obesity. Intra-procedure, the patient received one dose of 500 mg intravenous levofloxacin. Post-procedure, loperamide was prescribed every 8 h as needed for post-procedure diarrhea. Within 2 weeks, the patient was no longer taking anti-diarrheals. The post-procedure diet consisted of a liquid diet for 2 days before advancement to a low-residue diet for 1 month, and then a regular diet.

17.
Anat Histol Embryol ; 53(4): e13086, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38965883

ABSTRACT

Medical imaging techniques such as digital radiography and ultrasonography are non-invasive and provide precise results for examining internal organs and structures within fish. Their effectiveness can be further enhanced by using body parts like scales as markers for the organs beneath them. This study utilized the number of scales as landmarks in digital radiography and ultrasonography to non-invasively evaluate the muscles, bones, and images of internal and reproductive organs of common carp (Cyprinus carpio). Digital radiography was performed in the dorsoventral and lateral views of the fish, whereas ultrasonography was conducted in longitudinal and transverse views on sequence scale numbers with brightness and colour Doppler-modes. Digital radiography of the common carp revealed the whole-body morphology, including the bony parts from the head, pectoral fins, dorsal fins, pelvic fins, anal fins, and vertebrae to the tail that appeared radiopaque. Internal organs were also observed, with the swim bladder and heart appeared radiolucent, while the intestines, liver, testes, and ovaries appeared radiopaque. Ultrasonography in brightness mode displayed the digestive organs, reproductive organs, and muscle thickness. Additionally, colour Doppler mode demonstrated blood flow within the heart's ventricle.


Subject(s)
Carps , Animals , Carps/anatomy & histology , Female , Male , Ultrasonography/veterinary , Ultrasonography/methods , Radiographic Image Enhancement/methods , Animal Scales/anatomy & histology , Animal Scales/diagnostic imaging , Ultrasonography, Doppler, Color/veterinary , Ultrasonography, Doppler, Color/methods , Anatomic Landmarks/diagnostic imaging , Anatomic Landmarks/anatomy & histology , Liver/diagnostic imaging , Liver/anatomy & histology , Bone and Bones/diagnostic imaging , Bone and Bones/anatomy & histology
19.
J Robot Surg ; 18(1): 279, 2024 Jul 05.
Article in English | MEDLINE | ID: mdl-38967695

ABSTRACT

The role and risks of pre-operative endoscopic procedures, such as endoscopic retrograde cholangiopancreatography (ERCP) and endoscopic ultrasound with fine needle aspiration (EUS/FNA), in patients undergoing robotic pancreaticoduodenectomy are not well-defined despite a broad consensus on the utility of these interventions for diagnostic and therapeutic purposes prior to major pancreatic operations. This study investigates the impact of such preoperative endoscopic interventions on perioperative outcomes in robotic pancreaticoduodenectomy. With Institutional Review Board (IRB) approval we retrospectively analyzed 772 patients who underwent robotic pancreatectomies between 2012 and 2023. Specifically, 430 of these patients underwent a robotic pancreaticoduodenectomy were prospectively evaluated: 93 (22%) patients underwent ERCP with EUS and FNA, 45 (10%) ERCP only, and 31 (7%) EUS and FNA, while 261 (61%) did not. Statistical analyses were performed using chi-square tests and Student's t-tests to compare perioperative outcomes between the two cohorts. Statistically significant differences were observed in patients who underwent a pre-operative endoscopic intervention and were more likely to have converted to an open operation (p = 0.04). The average number of harvested lymph nodes for patients who underwent preoperative endoscopic intervention was statistically significant compared to those who did not (p = 0.0001). All other perioperative variables were consistent across all cohorts. Patients who underwent endoscopic intervention before robotic pancreaticoduodenectomy were more likely to have an unplanned open operation. This study demonstrates the increased operative difficulties introduced by preoperative endoscopic interventions. Although there was no impact on overall patient outcomes, surgeons' experience can minimize the associated risks.


Subject(s)
Cholangiopancreatography, Endoscopic Retrograde , Pancreaticoduodenectomy , Preoperative Care , Robotic Surgical Procedures , Humans , Pancreaticoduodenectomy/methods , Robotic Surgical Procedures/methods , Male , Female , Middle Aged , Aged , Retrospective Studies , Treatment Outcome , Preoperative Care/methods , Cholangiopancreatography, Endoscopic Retrograde/methods , Endoscopic Ultrasound-Guided Fine Needle Aspiration/methods , Pancreatic Neoplasms/surgery
20.
Sci Rep ; 14(1): 15343, 2024 07 03.
Article in English | MEDLINE | ID: mdl-38961222

ABSTRACT

This study aimed to construct a non-invasive diagnostic nomogram based on high-frequency ultrasound and magnetic resonance imaging results for early liver cirrhosis patients with chronic hepatitis B (CHB) which cannot be detected by conventional non-invasive examination methods but can only be diagnosed through invasive liver puncture for pathological examination. 72 patients with CHB were enrolled in this prospective study, and divided into S4 stage of liver cirrhosis and S0-S3 stage of non-liver cirrhosis according to pathological findings. Binary logistic regression analysis was performed to identify independent predictors, and a diagnostic nomogram was constructed for CHB-related early cirrhosis. It was validated and calibrated by bootstrap self-extraction. Binary logistic regression analysis showed that age (OR 1.14, 95% CI (1.04-1.27)), right hepatic vein diameter (OR 0.43, 95% CI 0.23-0.82), presence or absence of nodules (OR 31.98, 95% CI 3.84-266.08), and hepatic parenchymal echogenicity grading (OR 12.82, 95% CI 2.12-77.51) were identified as independent predictive indicators. The nomogram based on the 4 factors above showed good performance, with a sensitivity and specificity of 90.70% and 89.66%, respectively. The area under the curve (AUC) of the prediction model was 0.96, and the predictive model showed better predictive performance than APRI score (AUC 0.57), FIB-4 score (AUC 0.64), INPR score (AUC 0.63), and LSM score (AUC 0.67). The calibration curve of the prediction model fit well with the ideal curve, and the decision curve analysis showed that the net benefit of the model was significant. The nomogram in this study can detect liver cirrhosis in most CHB patients without liver biopsy, providing a direct, fast, and accurate practical diagnostic tool for clinical doctors.


Subject(s)
Hepatitis B, Chronic , Liver Cirrhosis , Nomograms , Ultrasonography , Humans , Liver Cirrhosis/diagnosis , Liver Cirrhosis/diagnostic imaging , Liver Cirrhosis/pathology , Liver Cirrhosis/complications , Male , Female , Middle Aged , Prospective Studies , Hepatitis B, Chronic/complications , Hepatitis B, Chronic/pathology , Adult , Magnetic Resonance Imaging/methods , Liver/pathology , Liver/diagnostic imaging
SELECTION OF CITATIONS
SEARCH DETAIL
...