Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 20
Filter
1.
Adv Rheumatol ; 63(1): 48, 2023 10 06.
Article in English | MEDLINE | ID: mdl-37803481

ABSTRACT

BACKGROUND: Juvenile Dermatomyositis (JDM) is the most common idiopathic inflammatory myopathy in children. Imaging exams are useful for muscle assessment, with ultrasonography (US) being a promising tool in detecting disease activity and tissue damage. There are few studies about muscle elastography. OBJECTIVES: Our aim was to associate clinical, laboratory, and nailfold capillaroscopy (NC) assessments with US in JDM patients; and to compare the findings of US and Strain Elastography (SE) from patients and healthy controls. METHODS: An analytic cross-sectional study was performed with JDM patients and healthy controls. Patients underwent clinical exam to access muscle strength and completed questionnaires about global assessment of the disease and functional capacity. Patients were submitted to NC and measurement of muscle enzymes. All subjects underwent US assessment, using gray scale, Power Doppler (PD), and SE. RESULTS: Twenty-two JDM patients and fourteen controls, aged between 5 and 21 years, matched for age and sex were assessed. In qualitative and semi-quantitative gray scale, we observed a higher frequency of alterations in patients (p < 0.001), while in PD, there was a higher frequency of positivity in patients' deltoids and anterior tibialis (p < 0.001). Active disease was associated with an important change in the semi-quantitative gray scale in deltoids (p = 0.007), biceps brachii (p = 0.001) and quadriceps femoris (p = 0.005). The SE demonstrated a high negative predictive value of 87.2. CONCLUSION: US was able, through gray scale, to differentiate JDM patients from controls, while PD achieved such differentiation only for deltoids and anterior tibialis. The semi-quantitative gray scale showed disease activity in proximal muscles. SE was not able to differentiate patients from controls.


Subject(s)
Dermatomyositis , Elasticity Imaging Techniques , Child , Humans , Child, Preschool , Adolescent , Young Adult , Adult , Dermatomyositis/diagnosis , Microscopic Angioscopy , Cross-Sectional Studies , Muscle, Skeletal/diagnostic imaging
2.
Adv Rheumatol ; 63: 48, 2023. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1519966

ABSTRACT

Abstract Background Juvenile Dermatomyositis (JDM) is the most common idiopathic inflammatory myopathy in children. Imaging exams are useful for muscle assessment, with ultrasonography (US) being a promising tool in detecting disease activity and tissue damage. There are few studies about muscle elastography. Objectives Our aim was to associate clinical, laboratory, and nailfold capillaroscopy (NC) assessments with US in JDM patients; and to compare the findings of US and Strain Elastography (SE) from patients and healthy controls. Methods An analytic cross-sectional study was performed with JDM patients and healthy controls. Patients underwent clinical exam to access muscle strength and completed questionnaires about global assessment of the disease and functional capacity. Patients were submitted to NC and measurement of muscle enzymes. All subjects underwent US assessment, using gray scale, Power Doppler (PD), and SE. Results Twenty-two JDM patients and fourteen controls, aged between 5 and 21 years, matched for age and sex were assessed. In qualitative and semi-quantitative gray scale, we observed a higher frequency of alterations in patients (p < 0.001), while in PD, there was a higher frequency of positivity in patients' deltoids and anterior tibialis (p < 0.001). Active disease was associated with an important change in the semi-quantitative gray scale in deltoids (p = 0.007), biceps brachii (p = 0.001) and quadriceps femoris (p = 0.005). The SE demonstrated a high negative predictive value of 87.2. Conclusion US was able, through gray scale, to differentiate JDM patients from controls, while PD achieved such differentiation only for deltoids and anterior tibialis. The semi-quantitative gray scale showed disease activity in proximal muscles. SE was not able to differentiate patients from controls.

3.
Belo Horizonte; s.n; 2023. 69 p. ilus, tab.
Thesis in Portuguese | BBO - Dentistry | ID: biblio-1524945

ABSTRACT

O diagnóstico da Síndrome de Sjögren (SS) é baseado em achados clínicos, sorológicos e microscópicos. O exame de ultrassom (US) evidencia danos estruturais nas glândulas salivares maiores que podem contribuir no diagnóstico da SS. Assim, o objetivo deste estudo foi analisar as características ultrassonográficas dos pacientes com SS (grupo SS), e dos pacientes com secura bucal que não preencheram os critérios atuais do Colégio Americano e Liga Europeia de Reumatologia (ACR/EULAR), (grupo Sicca não-SS); e analisar a associação da imagens do US com parâmetros clínicos, sorológicos e microscópicos. Para isso, 40 pacientes pareados, dos grupos SS (n=20) e Sicca não-SS (n=20), foram recrutados e as parótidas e submandibulares examinadas no US com o método OMERACT nos modos B e color Doppler por examinador cego. As imagens obtidas foram classificadas como ausente, leve, moderada ou severa, correspondendo aos scores 0, 1, 2 ou 3, respectivamente. Para fins de estatística, os dados foram dicotomizados em ausente ou leve e moderada ou severa. Características tais como fluxo salivar não-estimulado (FSNE), xeroftalmia, focus score (FS), bem como sorologia para fator antígeno nuclear (FAN), fator reumatoide (FR), anticorpos anti-SSA/Ro e antiSSB/La foram obtidos dos prontuários ou coletados durante o estudo. Análises estatísticas comparativas da avaliação do US, bem como a relação desta avaliação com as diferentes características foram realizadas. No grupo Sicca não-SS houve maior prevalência de glândulas salivares sem alteração ou com alteração leve, quando comparados com o grupo SS, nos quais as alterações moderada ou severa foram mais prevalentes (p<0,05). No color Doppler a glândula parótida do grupo Sicca não-SS apresentou mais fluxo vascular normal ou com alteração leve, em comparação ao grupo SS (p<0,05). Presença de xeroftalmia, anti-SSA/Ro, FAN, FR e FS positivos foram mais frequentes no grupo SS e em pacientes com alterações moderada ou severa na análise do US no modo b (p<0,05). O FSNE não diferiu entre os grupos ou com o grau de alteração das glândulas (p<0,05). As características do US das parótidas e submandibulares utilizando o sistema OMERACT modo B permitiram uma distinção entre os grupos SS e Sicca não-SS. Os resultados corroboram para que o US seja incorporado como uma possibilidade de exame não invasivo complementar no Hospital das clinicas da Universidade Federal de Minas Gerais (HC/UFMG) e em outros centros de referência de tratamento da Doença, que ainda têm tido o uso do US pouco explorado.


The diagnosis of Sjögren's Syndrome (SS) is based on clinical, serological, and microscopic findings. Ultrasound (US) examination can reveal structural damage in major salivary glands, which can contribute to the diagnosis of SS. Therefore, the objective of this study was to analyze the ultrasonographic characteristics of patients with SS (SS group) and patients with dry mouth who did not meet the current criteria of the American College of Rheumatology and European League Against Rheumatism (ACR/EULAR) for SS (non-SS sicca group). Additionally, we aimed to analyze the association of US images with clinical, serological, and microscopic parameters. For this purpose, 40 matched patients from the SS group (n=20) and non-SS sicca group (n=20) were recruited, and the parotid and submandibular glands were examined using the OMERACT method in B and color Doppler modes by a blinded examiner. The obtained images were classified as absent, mild, moderate, or severe, corresponding to scores 0, 1, 2, or 3, respectively. For statistical purposes, the data were dichotomized as absent or mild and moderate or severe. Characteristics such as unstimulated whole saliva flow rate (UWS), xerophthalmia, focus score (FS), as well as serology for antinuclear antibody (ANA), rheumatoid factor (RF), anti-SSA/Ro, and anti-SSB/La were obtained from medical records or collected during the study. Comparative statistical analyses of the US evaluation, as well as the relationship of this evaluation with different characteristics, were performed. In the non-SS sicca group, there was a higher prevalence of salivary glands with no alteration or mild alteration when compared to the SS group, in which moderate or severe changes were more prevalent (p<0.05). In the color Doppler, the parotid gland in the non-SS sicca group showed more normal vascular flow or mild alteration compared to the SS group (p<0.05). The presence of xerophthalmia, positive anti-SSA/Ro, ANA, RF, and FS was more frequent in the SS group and in patients with moderate or severe changes in the B-mode US analysis (p<0.05). UWS did not differ between the groups or with the degree of gland alterations (p<0.05). The US characteristics of the parotid and submandibular glands using the OMERACT B-mode system allowed for differentiation between the SS and non-SS sicca groups. The results support the incorporation of US as a non-invasive complementary examination at the Hospital das Clínicas da Universidade Federal de Minas Gerais (HC/UFMG) and at other reference centers for the treatment of the disease, where the use of US has been underutilized.


Subject(s)
Salivary Glands , Autoimmune Diseases , Diagnostic Imaging , Sjogren's Syndrome , Ultrasonography
4.
Arq. bras. cardiol ; 116(3): 383-392, Mar. 2021. tab, graf
Article in English, Portuguese | LILACS | ID: biblio-1248857

ABSTRACT

Resumo Fundamento Existem informações conflitantes sobre se a ultrassonografia pulmonar avaliada por linhas B tem valor prognóstico em pacientes com insuficiência cardíaca (ICa). Objetivos Avaliar o valor prognóstico da ultrassonografia pulmonar avaliada por linhas B em pacientes com ICa. Métodos Quatro bases de dados (PubMed, EMBASE, Cochrane Library e Scopus) foram sistematicamente pesquisadas para identificar artigos relevantes. Reunimos a razão de risco (RR) e o intervalo de confiança de 95% (IC) de estudos elegíveis e realizamos análises de heterogeneidade, avaliação de qualidade e viés de publicação. Os dados foram agrupados usando um modelo de efeitos fixos ou de efeito aleatório. Um valor de p <0,05 foi considerado para indicar significância estatística. Resultados Nove estudos envolvendo 1.212 participantes foram incluídos na revisão sistemática. As linhas B > 15 e > 30 na alta hospitalar foram significativamente associadas ao aumento do risco de desfecho combinado de mortalidade por todas as causas ou hospitalização por ICa (RR, 3,37, IC de 95%, 1,52-7,47; p = 0,003; RR, 4,01, IC de 95%, 2,29-7,01; p <0,001, respectivamente). O ponto de corte da linha B > 30 na alta foi significativamente associado ao aumento do risco de hospitalização por ICa (RR, 9,01, IC de 95%, 2,80-28,93; p <0,001). Além disso, o ponto de corte da linha B > 3 aumentou significativamente o risco de desfecho combinado de mortalidade por todas as causas ou hospitalização por ICa em pacientes ambulatoriais com ICa (RR, 3,21, IC de 95%, 2,09-4,93; I2 = 10%; p <0,00001). Conclusão As linhas B podem predizer mortalidade por todas as causas e hospitalizações por ICa em pacientes com ICa. Outros grandes ensaios clínicos randomizados são necessários para explorar se lidar com as linhas B melhoraria o prognóstico nos ambientes clínicos. (Arq Bras Cardiol. 2020; [online].ahead print, PP.0-0)


Abstract Background There is conflicting information about whether lung ultrasound assessed by B-lines has prognostic value in patients with heart failure (HF). Objectives To evaluate the prognostic value of lung ultrasound assessed by B-lines in HF patients. Methods Four databases (PubMed, EMBASE, Cochrane Library, and Scopus) were systematically searched to identify relevant articles. We pooled the hazard ratio (HR) and 95% confidence interval (CI) from eligible studies and carried out heterogeneity, quality assessment, and publication bias analyses. Data were pooled using a fixed-effects or random-effect model. A p value < 0.05 was considered to indicate statistical significance. Results Nine studies involving 1,212 participants were included in the systematic review. B-lines > 15 and > 30 at discharge were significantly associated with increased risk of combined outcomes of all-cause mortality or HF hospitalization (HR, 3.37, 95% CI, 1.52-7.47; p = 0.003; HR, 4.01, 95% CI, 2.29-7.01; p < 0.001, respectively). A B-line > 30 cutoff at discharge was significantly associated with increased risk of HF hospitalization (HR, 9.01, 95% CI, 2.80-28.93; p < 0.001). Moreover, a B-line > 3 cutoff significantly increased the risk for combined outcomes of all-cause mortality or HF hospitalization in HF outpatients (HR, 3.21, 95% CI, 2.09-4.93; I2 = 10%; p < 0.00001). Conclusion B-lines could predict all-cause mortality and HF hospitalizations in patients with HF. Further large randomized controlled trials are needed to explore whether dealing with B-lines would improve the prognosis in clinical settings.


Subject(s)
Humans , Heart Failure/diagnostic imaging , Prognosis , Ultrasonography , Hospitalization , Lung
5.
Int. j. cardiovasc. sci. (Impr.) ; 33(3): 227-232, May-June 2020. tab, graf
Article in English | LILACS | ID: biblio-1134357

ABSTRACT

Abstract Background: Hepatic congestion is a frequent finding in patients with heart failure (HF). Physical examination has limitations in quantifying systemic congestion and requires correlation with echocardiographic and laboratory data (usually B-type natriuretic peptide, BNP, or N-terminal pro-B type natriuretic peptide, NT-proBNP). Hepatic elastography evaluates liver stiffness using a transducer that transmits low-frequency vibrations (50 Hz), and the speed of shear waves propagating through the tissues is measured by ultrasound. The faster the vibrations propagate in the hepatic parenchyma, the stiffer the liver, which, in case of HF, can be correlated with hepatic congestion. Objective: In this systematic review, case-controls, cohort studies, and randomized clinical trials were searched in MEDLINE, LILACS and Cochrane Database of Systematic Review, to evaluate the use of elastography in the detection of hepatic congestion in patients with HF. Methods: From the 49 articles retrieved, seven were selected for review, according to the inclusion and exclusion criteria. The most used methods for the diagnosis and evaluation of HF were echocardiography combined with BNP and NT-proBNP measurements. Results: Elastography performed at bedside was able to establish a significant correlation between increased liver stiffness and increased venous capillary pressure. In addition, liver elastography performed at hospital discharge was able to predict rehospitalization and mortality. Conclusion: Liver elastography is a non-invasive method that can be useful in predicting prognosis and mortality of individuals with HF, contributing to the clinical management of these patients.


Subject(s)
Elasticity Imaging Techniques/methods , Heart Failure/physiopathology , Heart Failure/diagnostic imaging , Prognosis , Cohort Studies , Natriuretic Peptides/blood , Heart Failure/mortality , Hospitalization , Liver Diseases/diagnostic imaging
6.
Rev. Col. Bras. Cir ; 47: e20202530, 2020. tab, graf
Article in English | LILACS | ID: biblio-1136531

ABSTRACT

ABSTRACT Introduction: simulation based teaching is a powerful tool in medical education, allowing hands on practice under a controlled environment and with repeated maneuvers. Central venous access venipuncture is one of the most frequent procedures carried out in the hospital setting, due to its various clinical indications and, when performed with the help of ultrasonography, the risk of adverse events is minimized. Aim: to develop, to describe and to test a porcine model that simulates the central venous access puncture aided by ultrasonography. Method: a low cost porcine model was developed to train medical students and residents on central venous access guided by ultrasonography. Both students and medical residents underwent a theoretical training regarding the model, followed by a hands-on training session. Afterwards, the participants assessed the model by answering a questionnaire. Results: there were 51 participants. The average score regarding the similarity between the model and the human anatomy was 9.15. When the characteristics were separately assessed, the mean scores regarding the similarity of the vessels, anatomic disposition and ultrasonographic characteristics as well as the venipuncture were, respectively, 9.27; 9.31; 9.54 and 8.86. Conclusion: The model was approved and considered appropriate for the training of central venous venipuncture by all the participants. Furthermore, it is a low cost, simple and reproducible model, that presents high similarity with the human anatomy. Therefore, it may be used as an aid to train people on ultrasonography guided central venous access.


RESUMO Introdução: o ensino baseado em simulação é poderosa ferramenta para o aprendizado na educação médica, permitindo a prática de procedimentos em ambientes controlados e por repetidas vezes. A realização de acesso venoso central é um dos procedimentos médicos mais realizados em ambiente hospitalar, tendo várias indicações e, quando realizada com o auxilio da ultrassonografia, os riscos das complicações do procedimento são minimizados. Objetivo: desenvolver, descrever e aplicar um modelo porcino para simulação de acesso venoso central guiado por ultrassonografia. Métodos: modelo porcino de baixo custo foi desenvolvido para treinamento de acesso venoso central guiado por ultrassonografia. Estudantes de medicina e médicos residentes receberam treinamento teórico em relação ao procedimento, seguido de treinamento prático no modelo. Posteriormente, os participantes avaliaram o modelo desenvolvido por meio de um questionário. Resultados: o estudo contou com 51 participantes. O escore médio de semelhança geral do modelo com a realidade foi 9,15. Quando separadas por características, as médias dos escores de semelhança da imagem dos vasos, da disposição anatômica das estruturas, das características ultrassonográficas e da punção foram, respectivamente, 9,27; 9,31; 9,54 e 8,86. Conclusão: o modelo foi aprovado e considerado útil para treinamento do procedimento por todos os participantes, além de ter baixo custo, ser simples, reprodutível e apresentar alta semelhança com a realidade, podendo ser utilizado como adjunto no treinamento de acesso venoso central guiado por ultrassonografia.


Subject(s)
Humans , Students, Medical/psychology , Ultrasonography, Interventional/methods , Education, Medical , Central Venous Catheters , Swine , Models, Animal , Simulation Training
7.
Arq. bras. cardiol ; 110(6): 577-584, June 2018. tab, graf
Article in English | LILACS | ID: biblio-950170

ABSTRACT

Abstract Pulmonary congestion is an important clinical finding in patients with heart failure (HF). Physical examination and chest X-ray have limited accuracy in detecting congestion. Pulmonary ultrasound (PU) has been incorporated into clinical practice in the evaluation of pulmonary congestion. This paper aimed to perform a systematic review of the use of PU in patients with HF, in different scenarios. A search was performed in the MEDLINE and LILACS databases in February 2017 involving articles published between 2006 and 2016. We found 26 articles in the present review, 11 of which in the emergency setting and 7 in the outpatient setting, with diagnostic and prognosis defined value and poorly studied therapeutic value. PU increased accuracy by 90% as compared to physical examination and chest X-ray for the diagnosis of congestion, being more sensitive and precocious. The skill of the PU performer did not interfere with diagnostic accuracy. The presence of B-lines ≥ 15 correlated with high BNP values (≥ 500) and E/e' ratio ≥ 15, with prognostic impact in IC patients at hospital discharge and those followed up on an outpatient basis. In conclusion, when assessing pulmonary congestion in HF, PU has an incremental value in the diagnostic and prognostic approach in all scenarios studied.


Resumo A congestão pulmonar é um achado clínico importante em paciente com insuficiência cardíaca (IC). Exame físico e radiografia do tórax têm acurácia limitada na detecção da congestão. A ultrassonografia pulmonar (UP) vem sendo incorporada à prática clínica na avaliação da congestão pulmonar. Este artigo teve como objetivo realizar revisão sistemática sobre a utilização da UP em pacientes com IC, nos diferentes cenários. Foi realizada uma pesquisa nas bases de dados MEDLINE e LILACS no mês de fevereiro de 2017 envolvendo artigos publicados entre 2006 e 2016. Foram encontrados 26 artigos na presente revisão, 11 deles no cenário da emergência e 7 em cenário ambulatorial, com valor diagnóstico e prognóstico definido e valor terapêutico pouco estudado. A UP aumentou a acurácia em 90% em relação ao exame físico e à radiografia do tórax para o diagnóstico da congestão, sendo mais sensível e precoce. A qualificação do executor da UP não interferiu na acurácia diagnóstica. O achado de linhas B ≥ 15 teve correlação com BNP elevado (≥ 500) e relação E/e' ≥ 15, com impacto prognóstico em pacientes com IC ambulatoriais e na alta hospitalar. Conclui-se que, na avaliação da congestão pulmonar na IC, a UP tem valor incremental na abordagem diagnóstica e prognóstica em todos os cenários encontrados.


Subject(s)
Humans , Pulmonary Edema/diagnostic imaging , Heart Failure/diagnostic imaging , Prognosis , Reproducibility of Results , Ultrasonography , Sensitivity and Specificity , Lung/diagnostic imaging
8.
Rev. bras. anestesiol ; 68(3): 280-284, May-June 2018. tab, graf
Article in English | LILACS | ID: biblio-958297

ABSTRACT

Abstract Study objective: The purpose of this study was to assess whether application of dorsal table tilt and body rotation to a parturient seated for neuraxial anesthesia increased the size of the paramedian target area for neuraxial needle insertion. Setting: Labor and Delivery Room. Patients: Thirty term pregnant women, ASA I-II, scheduled for an elective C-section delivery. Interventions: Lumbar ultrasonography was performed in four seated positions: (F) lumbar flexion; (FR) as in position F with right shoulder rotation; (FT) as in position F with dorsal table-tilt; (FTR) as in position F with dorsal table-tilt combined with right shoulder rotation. Measurements: For each position, the size of the 'target area', defined as the visible length of the posterior longitudinal ligament was measured at the L3-L4 interspace. Main results: The mean posterior longitudinal ligament was 18.4 ± 4 mm in position F, 18.9 ± 5.5 mm in FR, 19 ± 5.3 mm in FT, and 18 ± 5.2 mm in FTR. Mean posterior longitudinal ligament length was not significantly different in the four positions. Conclusions: These data show that the positions studied did not increase the target area as defined by the length of the posterior longitudinal ligament for the purpose of neuraxial needle insertion in obstetric patients. The maneuvers studied will have limited use in improving spinal needle access in pregnant women.


Resumo Objetivo do estudo: O objetivo deste estudo foi avaliar se a inclinação lateral da mesa cirúrgica e a rotação do corpo de uma parturiente sentada para anestesia neuraxial aumentou o tamanho da área-alvo paramediana para a inserção da agulha neuraxial. Ambiente: Sala de parto. Pacientes: Trinta grávidas a termo, ASA I-II, agendadas para cesárea eletiva. Intervenções: Ultrassonografia lombar foi feita em quatro posições sentadas: (F) flexão lombar; (FR) como na posição F com rotação do ombro direito; (FT) como na posição F com inclinação lateral da mesa cirúrgica; (FTR) como na posição F com inclinação lateral da mesa cirúrgica combinada com a rotação do ombro direito. Mensurações: Para cada posição, o tamanho da "área-alvo", definido como o comprimento visível do ligamento longitudinal posterior, foi medido no interespaço de L3-L4. Principais resultados: As médias do ligamento longitudinal posterior foram: 18,4 ± 4 mm na posição F; 18,9 ± 5,5 mm na posição FR; 19 ± 5,3 mm na posição FT e 18 ± 5,2 mm na posição FTR. O comprimento médio do ligamento longitudinal posterior não foi significativamente diferente nas quatro posições. Conclusões: Esses dados mostram que as posições avaliadas não aumentaram a área-alvo, conforme definido pelo comprimento do ligamento longitudinal posterior com o objetivo de inserção da agulha neuraxial em pacientes obstétricas. As manobras avaliadas terão um uso limitado na melhoria do acesso à agulha espinhal em mulheres grávidas.


Subject(s)
Humans , Female , Pregnancy , Cesarean Section/instrumentation , Longitudinal Ligaments , Anesthesia, Obstetrical/methods , Ultrasonography/methods
9.
Braz J Anesthesiol ; 68(3): 280-284, 2018.
Article in Portuguese | MEDLINE | ID: mdl-29631875

ABSTRACT

STUDY OBJECTIVE: The purpose of this study was to assess whether application of dorsal table tilt and body rotation to a parturient seated for neuraxial anesthesia increased the size of the paramedian target area for neuraxial needle insertion. SETTING: Labor and Delivery Room. PATIENTS: Thirty term pregnant women, ASA I-II, scheduled for an elective C-section delivery. INTERVENTIONS: Lumbar ultrasonography was performed in four seated positions: (F) lumbar flexion; (FR) as in position F with right shoulder rotation; (FT) as in position F with dorsal table-tilt; (FTR) as in position F with dorsal table-tilt combined with right shoulder rotation. MEASUREMENTS: For each position, the size of the 'target area', defined as the visible length of the posterior longitudinal ligament was measured at the L3-L4 interspace. MAIN RESULTS: The mean posterior longitudinal ligament was 18.4±4mm in position F, 18.9±5.5mm in FR, 19±5.3mm in FT, and 18±5.2mm in FTR. Mean posterior longitudinal ligament length was not significantly different in the four positions. CONCLUSIONS: These data show that the positions studied did not increase the target area as defined by the length of the posterior longitudinal ligament for the purpose of neuraxial needle insertion in obstetric patients. The maneuvers studied will have limited use in improving spinal needle access in pregnant women.

10.
Surg. cosmet. dermatol. (Impr.) ; 9(3): 252-254, jul.-set. 2017. ilus.
Article in English, Portuguese | LILACS | ID: biblio-880429

ABSTRACT

A presença de corpos estranhos localizados na pele, sua dimensão, constituição e exata localização muitas vezes não são perceptíveis ao exame clínico dermatológico. Apesar de seu caráter benigno, a existência de corpos estranhos à pele provocam alta morbidade. A ultrassonografia de alta frequência tem sido amplamente utilizada nas diferentes áreas da Dermatologia. O avanço tecnológico com a introdução de aparelhos de alta frequência e resolução torna esse método útil na identificação e orientação da remoção de corpos estranhos localizados na pele. Apresentamos caso em que a ultrassonografia de alta frequência foi utilizada na identificação e retirada de um ferrão de arraia.


The presence of foreign bodies located on the skin, their size, constitution and precise location are often not perceptible on dermatological clinical examination. Despite their benign nature, the presence of foreign bodies in the skin is associated to high morbidity. High frequency ultrasonography has been widely used in different areas of Dermatology. Technological development and the introduction of devices offering high frequency and high resolution makes this method useful in identifying and guiding the removal of foreign bodies located in the skin. The authors describe a case where high frequency ultrasonography was used to identify and remove a rayfish stinger.

11.
Rev. bras. mastologia ; 25(4): 141-145, out.-dez. 2015. ilus
Article in Portuguese | LILACS-Express | LILACS | ID: lil-781047

ABSTRACT

O câncer de mama em homens é uma patologia relativamente incomum. Atinge um homem para cada mil mulheres. Representa menos de 1% de todos os cânceres em homens e é responsável por 0,1% da mortalidade de câncer no sexo masculino. Apesar de ser incomum, alguns estudos vêm demonstrando um aumento na incidência destes tumores. Os fatores de risco incluem hiperestrogenismo, idade, ascendência judaica, história familiar e Síndrome de Klinefelter. Os dados sobre patologia mostram que 90% dos tumores são ductais invasivos, 80% apresentam receptores de estrógeno e 80 a 90% receptores de progesterona positivos. O tratamento é extrapolado dos estudos sobre câncer de mama feminina: cirurgia, hormonioterapia, quimioterapia e radioterapia, que são usados seguindo os guidelines femininos.


Breast cancer in men is a relatively an uncommon disease. Reaches one man for every thousand women. Represents less than 1% of all cancers in men and is responsible for 0.1% of cancer mortality in males. Although it is uncommon, some studies have demonstrated an incidence increase of these tumors. Risk factors include hyperestrogenism, age, Jewish ancestry, family history and Klinefelter Syndrome. The data on pathology showed that 90% of tumors are invasive ductal, 80% have estrogen receptors and 80 to 90% progesterone receptor positive. The treatment is extrapolated from female breast cancer studies: surgery, hormone therapy, chemotherapy and radiotherapy, wich are used following the guidelines female.

12.
Rev. bras. mastologia ; 25(2): 60-63, abr-jun 2015. ilus
Article in Portuguese | LILACS-Express | LILACS | ID: lil-782256

ABSTRACT

Relatamos um caso de uma paciente assintomática, cuja mamografia demonstrou nódulo contendo calcificações e ultrassonografia, imagem semelhante a agrupamento de pequenos cistos. Este achado é inespecífico, mas pode ser encontrado em vários transtornos proliferativos benignos ou fibrocísticos e também no carcinoma ductal in situ. Foi também obtida a tomossíntese e a ressonância magnética, que confirmaram os achados.


It was related a case of an asymptomatic patient, whose mammography presented a nodule with calcification and the ultrasound images showed a group of small cysts. This is a nonspecific finding, but can be found in several benign or fibrocystic proliferative diseases, and even in ductal carcinoma in situ. The findings confirmation was made by digital breast tomosynthesis and magnetic resonance.

13.
Eur J Obstet Gynecol Reprod Biol ; 190: 7-10, 2015 Jul.
Article in English | MEDLINE | ID: mdl-25917436

ABSTRACT

OBJECTIVE: To evaluate the reliability of fetal heart rate (FHR) parameters analyzed by computerized cardiotocography (cCTG) in predicting myocardial damage in pregnancies with placental insufficiency. STUDY DESIGN: We evaluated 38 patients with placental insufficiency detected before 34 weeks of gestation. All patients underwent 30 min of cCTG (Sonicaid Fetal Care, version 2.2) and Doppler of umbilical artery, middle cerebral artery, and ductus venosus. Umbilical vein blood samples were collected at birth to determine fetal cardiac Troponin T, and a ≥0.09ng/ml value was deemed a sign of myocardial damage. RESULTS: The fetuses with myocardial damage (39%) showed significantly increased values of umbilical artery pulsatility index z-score (P=0.003), ductus venosus pulsatility index z-score (P=0.007), basal FHR (P=0.033) and periods of low episodes (P=0.038). The number of small accelerations and the short-term variation (STV) were significantly reduced in the group with myocardial damage (P=0.013 and P=0.003, respectively). Logistic regression analysis identified STV and gestational age at delivery as independent predictors for fetal myocardial damage, with area under ROC curve of 0.91. CONCLUSIONS: Computerized cardiotocography parameters may be useful in the management of early onset placental insufficiency, and the association of STV with gestational age could play a role in detecting myocardial injury in pregnancies with placental insufficiency.


Subject(s)
Cardiotocography , Heart Rate, Fetal , Myocardium/pathology , Placental Insufficiency/physiopathology , Area Under Curve , Female , Fetal Blood/metabolism , Gestational Age , Humans , Middle Cerebral Artery/diagnostic imaging , Placental Insufficiency/diagnostic imaging , Predictive Value of Tests , Pregnancy , ROC Curve , Signal Processing, Computer-Assisted , Troponin T/blood , Ultrasonography, Doppler , Umbilical Arteries/diagnostic imaging , Umbilical Veins/diagnostic imaging
14.
Braz. j. vet. res. anim. sci ; 50(2): 105-113, 2013.
Article in English | LILACS | ID: lil-696352

ABSTRACT

Bones are believed to be an effective barrier to obtain sonographic images. In fact, the large difference between acoustic impedances of surfaces of the soft and bone tissues generates significant image artifacts. However, transmission of the ultrasound beam depends on bone thickness and structure. Therefore, the temporal bone has been used as an acoustic window to access the brain of adult patients with ultrasonography. The purpose of this study was to assess the brain of adult dogs using ultrasonography with and without bone interposition, compare the images, and correlate them with the brain anatomy. Ten mesaticephalic adult dogs were used, and the ultrasound examination was performed through the magnum orifice and on the temporal, lateral parietal, and frontal bones. A small craniotomy was performed in the frontal bone for examination without bone interposition. We were able to acquire images of the brain with bone interposition. However, resolution of these images was lower than the ones obtained by craniotomy. Important anatomical structures were identified. Regarding the correlation and the wide availability of ultrasound equipment, it was concluded that ultrasound can be used as a tool for monitoring expansive intracranial lesions or in intraoperative procedures.


Os ossos são tidos como uma barreira intransponível para obtenção de imagens sonográficas, pois a grande diferença entre as impedâncias acústicas das superfícies de tecidos moles e ósseos gera importantes artefatos de reflexão, contudo, a transmissão do feixe ultrassônico depende da espessura e da estrutura óssea e neste caso o osso temporal tem sido usado como uma janela acústica para o acesso, por ultrassonografia, do encéfalo de pacientes adultos. O presente trabalho examinou o encéfalo de cães adultos com o emprego da ultrassonografia com e sem a interposição do crânio, comparou as imagens obtidas e as correlacionou com a anatomia encefálica. Foram examinados dez cães adultos, mesaticefálicos. O exame ultrassonográfico foi realizado através do orifício magno e dos ossos temporal, parietal (porção lateral) e frontal. No exame sem a interposição óssea foi realizada uma pequena craniotomia no osso frontal. As imagens do encéfalo com a interposição óssea apresentaram resolução inferior as obtidas por craniotomia. Importantes estruturas anatômicas foram identificadas. Devido à correlação e a sua ampla disponibilidade, concluiu-seque o aparelho de ultrassom pode ser usado para o acompanhamento de lesões intracranianas expansivas, bem como em procedimentos intraoperatórios.


Subject(s)
Animals , Anatomy , Cerebrum/anatomy & histology , Skull/anatomy & histology , Ultrasonography , Dogs
15.
Rev. bras. cardiol. invasiva ; 20(2): 199-203, abr.-jun. 2012. ilus
Article in English, Portuguese | LILACS | ID: lil-649573

ABSTRACT

Introdução: O ultrassom intracoronário (USIC) é um método capaz de fornecer medida sensível e reprodutível das dimensões da artéria coronária, da placa aterosclerótica e do lúmen arterial. Avanços em sua tecnologia permitem agora a caracterização da composição e da morfologia das placasateroscleróticas. Embora estudos prévios tenham reportado dados utilizando USIC com análise de radiofrequência, o uso de uma nova modalidade (iMap®, Boston Scientific, Santa Clara, Estados Unidos) de caracterização da placa ateroscleróticaé muito pouco conhecida. Nosso objetivo será analisar as características morfológicas, teciduais e fenotípicas das placas ateroscleróticas consideradas angiograficamente “culpadas” e“não-culpadas” em pacientes submetidos a angiografia coronáriadecorrente de infarto agudo do miocárdio (IAM). Métodos: Estudo prospectivo, transversal, em único centro (Hospital São Paulo – Escola Paulista de Medicina – UniversidadeFederal de São Paulo/UNIFESP, São Paulo, SP, Brasil). Serão selecionados50 pacientes para análise ultrassonográfica, de acordo com os seguintes critérios de inclusão: idade < 75 anos, IAM sem supradesnivelamento do segmento ST ou IAM com supradesnivelamento do segmento ST recente, com ou sem uso de fibrinolítico prévio. Conclusões: O presente estudoobjetivará a caracterização morfológica, tecidual e fenotípica da placa aterosclerótica utilizando uma nova modalidade de imagem ainda pouco estudada em pacientes com IAM.


Subject(s)
Humans , Coronary Artery Disease/complications , Coronary Artery Disease/diagnosis , Acute Coronary Syndrome/complications , Acute Coronary Syndrome/diagnosis , Ultrasonography/methods , Ultrasonography , Prospective Studies , Cross-Sectional Studies
16.
Femina ; 39(2): 97-102, fev. 2011.
Article in Portuguese | LILACS | ID: lil-604887

ABSTRACT

A ultrassonografia de mama é largamente utilizada na pratica clínica em pacientes com alterações detectáveis ao exame físico ou à mamografia. Na presença de lesões mamográficas, a ultrassonografia auxilia não só a caracterização e a realização de biópsias, como também é capaz de identificar lesões adicionais em 14% das mulheres com mamas densas. Entretanto, o rastreamento de mulheres com exame físico e mamografia normal é uma questão controversa na literatura. Alguns autores sugerem que a ultrassonografia pode ser uma ferramenta útil, principalmente para as mulheres com mamas densas ou com alto risco de câncer de mama, por ser capaz de diagnosticar alguns tumores não identificados de outra forma. Entretanto, o rastreamento do câncer de mama com adição de ultrassonografia à mamografia eleva os custos e gera grande número de exames falsos positivos, levando a procedimentos desnecessários. Algumas técnicas aplicadas à ultrassonografia podem melhorar sua especificidade, diminuindo os casos falsos positivos. Essas ferramentas são o uso de harmônica, Doppler, agentes de contraste ultrassonográficos, ultrassonografia tridimensional, ultrassonografia automatizada e elastografia mamária.(AU)


Breast ultrasound is widely used in clinical practice in patients with abnormalities on physical examination or mammography. In the presence of mammographic lesions, ultrasonography helps not only in its characterization and as biopsy guidance, but also identifies additional lesions in 14% of women with dense breasts. However, screening of women with normal physical examination and mammography is a controversial issue in literature. Some authors suggest that ultrasonography might be a useful tool, especially for women with dense breasts or at high risk of breast cancer, making it possible to diagnose some tumors not otherwise identified. However, the addition of ultrasound to mammography for breast cancer screening increases costs and generates a large number of false positives, leading to unnecessary procedures. Some techniques applied to ultrasound may improve its specificity, reducing false-positive cases. These tools are the use of harmonic, Doppler, ultrasound contrast agents, three-dimensional ultrasound, automated ultrasound and breast elastography.(AU)


Subject(s)
Humans , Female , Breast Neoplasms/diagnostic imaging , Ultrasonography, Mammary/instrumentation , Ultrasonography, Mammary/methods , Ultrasonography, Mammary/statistics & numerical data , Ultrasonography, Doppler , Contrast Media , Imaging, Three-Dimensional , Elasticity Imaging Techniques
17.
Sci. med ; 20(2)abr.-jun. 2010. ilus
Article in Portuguese | LILACS | ID: lil-567146

ABSTRACT

Objetivos: revisar dados da literatura relacionados ao uso da ultrassonografia pulmonar como método diagnóstico na insuficiência cardíaca agudamente descompensada. Fonte de Dados: artigos pesquisados na base de dados PubMed e edições recentes de livros. Síntese dos Dados: a insuficiência cardíaca descompensada consiste em uma síndrome altamente prevalente nos serviços de emergência. Frequentemente, o diagnóstico diferencial com outras síndromes associadas à insuficiência respiratória aguda representa uma tarefa complexa para o médico da sala de emergência, visto que a análise clínica e a radiografia de tórax não apresentam suficiente especificidade. A ultrassonografia pulmonar vem sendo estudada como uma nova técnica para o diagnóstico de insuficiência cardíaca aguda. Conclusões: a ultrassonografia pulmonar possui boa sensibilidade e especificidade para edema pulmonar intersticial, além de ter baixo custo e ser de fácil aprendizado. Portanto, apresenta boa aplicabilidade para direcionamento diagnóstico, tanto para confirmação de edema intersticial, quanto para exclusão de outras morbidades.


Aims: To review literature data concerning the use of pulmonary ultrasonography as a diagnostic method in acute decompensated heart failure. Source of Data: Articles found in the PubMed database and recent editions of books. Summary of Findings: Acute decompensated heart failure is a highly prevalent condition in the emergency room. The differential diagnosis from other syndromes associated with acute respiratory failure often represents a complex task for the emergency room physician, since clinical examination and chest radiography do not have sufficient specificity. Pulmonary ultrasonography has been studied as a new technique for the diagnosis of acute heart failure. Conclusions: Pulmonary ultrasonography has good sensitivity and specificity for pulmonary interstitial edema, in addition to low cost and ease of learning. Hence it has a good applicability for targeting diagnosis, both for confirmation of interstitial edema and for excluding other illnesses.


Subject(s)
Humans , Female , Male , Diagnosis, Differential , Pulmonary Edema , Heart Failure/diagnosis , Emergency Medicine , Lung
18.
São Paulo; s.n; 2010. 97 p. ilus.
Thesis in Portuguese | LILACS | ID: lil-579248

ABSTRACT

INTRODUÇÃO: Não há, até o momento, método ideal de avaliação da função renal em fetos com dilatação de vias urinárias. A ultrassonografia é utilizada como um método não invasivo e alguns parâmetros, como o índice de líquido amniótico, foram descritos na predição de insuficiência renal. Entretanto, a sensibilidade é baixa e a detecção de alterações, muitas vezes, ocorre tardiamente na gestação. A avaliação bioquímica da urina ou sangue fetais acrescenta risco à gestação e, apesar de melhorar a detecção de insuficiência renal, tem sensibilidade e especificidade baixas. O Power Doppler tridimensional é um método capaz de quantificar fluxo em órgãos parenquimatosos e tem sido utilizado na quantificação de fluxo sanguíneo de órgãos fetais e placenta. Como fetos com obstrução de vias urinárias e insuficiência renal apresentam diminuição no número de glomérulos, a quantificação do fluxo renal ao Power Doppler tridimensional poderia aprimorar a avaliação da função renal desses fetos. OBJETIVOS: quantificar o fluxo renal ao Power Doppler tridimensional em fetos com suspeita de obstrução de vias urinárias e naqueles com morfologia renal normal, avaliar a influência da profundidade nos índices vasculares e comparar os índices nos fetos que evoluíram com e sem insuficiência renal no período pós-natal. MÉTODOS: fetos com hidronefrose bilateral e/ou dilatação vesical foram prospectivamente comparados com fetos sem malformações em relação à quantificação do fluxo renal ao Power Doppler tridimensional. Os parâmetros avaliados foram IV, IVF, IF e a profundidade. Após o nascimento, as crianças foram seguidas por uma equipe de nefrologia e urologia e, de acordo com a função renal, foram classificadas em 2 grupos: insuficiência renal e função renal normal. A vascularização renal foi avaliada em cada grupo e comparada ao grupo controle. RESULTADOS: vinte e três fetos com dilatação de vias urinárias e setenta e três com morfologia renal normal foram considerados...


INTRODUCTION: There is no ideal method for prenatal evaluation of renal function whether there is a urinary tract dilatation in the fetus. Although ultrasound is a noninvasive method and some parameters have been described to evaluate fetal renal function, as amniotic fluid index, there is a lack of sensitivity to renal failure when ultrasound is used alone. Furthermore, ultrasound changes may appear late in pregnancy. Biochemical evaluation of fetal urine or blood may expose the fetus to some risk, and still lack sensitivity and specificity for renal failure. Threedimensional Power Doppler evaluation has been used to quantify blood flow in fetal organs and placenta. As urinary tract obstruction lead to decrease in renal glomeurli and consequently to a decrease in parenchymal renal flow, three-dimensional quantification of renal flow may improve the evaluation of fetal renal function in fetuses with renal dilatation. OBJECTIVES: To evaluate the ability of threedimensional evaluation of renal vascularization to predict postnatal renal prognosis in fetuses with suspicion of urinary obstruction and to analyze depth influence in vascular indexes. METHODS: Fetuses with bilateral hydronephrosis and/or bladder dilatation had renal vascularization evaluated by three-dimensional ultrasound and VOCAL and were prospectively compared to healthy fetuses. Parameters evaluated were VI, VFI, FI and the distance between the probe and the renal cortex. Follow up by urologists and nephrologists allowed us to allocate these fetuses in two groups: renal impairment and normal renal function. Renal vascularization was evaluated in each group and compared to controls. RESULTS: Twenty-three fetuses with urinary dilatation and seventy-three fetuses with normal renal morphology where considered for statistical analysis. Five fetuses (21,7%) developed renal impairment. VI and VFI where significantly lower in fetuses that developed renal impairment than in those with normal renal...


Subject(s)
Humans , Fetus , Hydronephrosis , Renal Insufficiency , Ultrasonography
19.
Femina ; 37(5): 267-272, maio 2009.
Article in Portuguese | LILACS | ID: lil-539344

ABSTRACT

A gestação normal é caracterizada por redução da resistência vascular sistêmica, que pode ser mediada pelo óxido nítrico. O óxido nítrico, derivado do endotélio, tem sido considerado de importante papel na redução da resistência vascular periférica em gestações normais. Muitos autores concluem que a tensão de acisalhamento (shear stress) induzida por fluxo é um potente estímulo para a vasodilatação em artérias de mulheres gestantes, e que esse mecanismo poderia conduzir a uma queda na resistência vascular periférica em gestantes normais. Falha desse mecanismo induzido por fluxo pode contribuir para complicações da gestação. Apresenta-se aqui uma revisão da literatura atualizada a respeito da vasodilatação mediada por fluxo, endotélio-dependente e aspectos da gestação.


Normal pregnancy is characterized by reduced systemic vascular resistance, which may be mediated by nitric oxide (NO). Endothelium-derived nitric oxide is considered to play an important role in the lowering of peripheral vascular resistance in normal pregnancy. Many authors conclude that flow-induced shear stress is a potential stimulus to vasodilatation in pregnant women's arteries and that this mechanism may lead to a decrease in peripheral vascular resistance in normal pregnancy. Failure of this flow-induced dilatation may contribute to gestational complications. The authors present herein a review of the updated literature with regard to endothelial-dependent flow-mediated and pregnancy's aspects.


Subject(s)
Female , Pregnancy , Brachial Artery , Diagnostic Techniques, Cardiovascular , Endothelium, Vascular/physiopathology , Endothelium, Vascular , Nitric Oxide/therapeutic use , Pre-Eclampsia/etiology , Regional Blood Flow , Vascular Resistance , Vasodilation
20.
Rev. bras. oftalmol ; 66(6): 376-382, nov.-dez. 2007. tab
Article in Portuguese | LILACS | ID: lil-482112

ABSTRACT

OBJETIVOS: Enfocar os exames de ultra-sonografia (US), tomografia computadorizada (TC) e ressonância magnética (RM), levantando, revisando e discutindo as seguintes medidas na melhoria da eficiência destes procedimentos na órbita: 1- Defasagem dos honorários médicos; 2- Vantagens e desvantagens dos exames; 3- Diretrizes clínicas. MÉTODOS: No período de julho de 2002 a março de 2003, realizou-se um levantamento dos valores dos exames orbitários de US, TC e RM pagos pelo Sistema Único de Saúde - SUS, operadoras de planos e seguros de saúde e particulares cobrados em três clínicas oftalmológicas e três clínicas radiológicas referenciadas. Pesquisa bibliográfica e revisão na literatura dos referidos exames e suas diretrizes clínicas nas afecções orbitárias. RESULTADOS: 1- Valores dos exames em reais (R$): US: 9,05 - SUS / 81,77 - AMB 90 / 57,01 - AMB/CIEFAS 93 / 102,00 - AMB/LPM 99 / 158,33 - particular. TC: 86,76 - SUS / 193,70 - AMB 90 / 196,30 - AMB/CIEFAS 93 / 204,12 - AMB/LPM 99 / 255,33 - particular. RM: 268,75 - SUS / 475,80 - AMB 90 e AMB/CIEFAS 93 / 472,50 - AMB/LPM 99 / 563,33 - particular; 2- Vantagens e desvantagens dos exames descritos de acordo com a revisão da literatura; 3- As doenças da órbita não têm ainda listadas suas diretrizes. CONCLUSÃO: Estes exames são os mais utilizados e consagrados pela sua eficácia no estudo da órbita. Para uma maior eficiência, devemos considerar as seguintes recomendações administrativas: 1- Modernização e atualização das tabelas de honorários com índices mínimos e mais justos na remuneração dos exames com reembolso dos insumos utilizados como filmes radiológicos e contrastes: 2- Promover e estimular a educação médica continuada, evitando o excesso de exames desnecessários ou inapropriados: 3- Elaboração e implementação de diretrizes e protocolos clínicos baseados em evidências nas principais doenças orbitárias que possam ser utilizados como referência.


PURPOSES:This study focuses the orbital exams of ultrassononography (US), computed tomography (CT) and magnetic resonance imaging (MRI), and has the following purposes: Collecting the paid amounts by Sistema Único de Saúde (SUS), Associação Médica Brasileira (AMB) and private clinic tables. Reviewing the advantages and disadvantages of the referred diagnostic tests. Suggesting administrative efficiency measures related to these tests in the orbit. METHODS: The costs were achieved based on the amounts paid by SUS, brazilian medical insurance companies and private clinics in Rio de Janeiro City. Bibliographic research of the advantages and disadvantages of these tests. RESULTS: Amounts of these tests in reais (R$): US: 9,05 SUS / 81,77 AMB 90 / 57,01 AMB/CIEFAS 93 / 102,00 AMB/LPM 99 / 158,33 private clinics. CT 86,76 SUS / 193,70 AMB90 / 196,30 AMB/CIEFAS 93 / 204,12 AMB/LPM 99 / 255,33 private clinics MRI: 268,75 SUS / 475,80 AMB 90 and AMB/CIEFAS 93 / 472,50 AMB/LPM 99 / 563,33 private clinics. The advantages and disadvantages of these tests were described according to the literature review. CONCLUSION: Knowing the tests costs and its advantages and disadvantages are important strategies to improve efficiency in diagnostic imaging. It was also concluded the need of new clinical studies that includes economic evaluation of cost-effectiveness in US, CT and MRI exams in orbital diseases which allow the development of clinical practice guidelines or clinical protocols to be applied in medical and administrative decision making.


Subject(s)
Orbital Diseases/diagnosis , Efficiency, Organizational , Magnetic Resonance Imaging , Orbit , Practice Management, Medical , Tomography, X-Ray Computed , Cost-Effectiveness Analysis , Fees and Charges , Unnecessary Procedures
SELECTION OF CITATIONS
SEARCH DETAIL
...