1.
Int. braz. j. urol ; 48(3): 456-467, May-June 2022. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1385115

ABSTRACT

ABSTRACT Flexible ureteroscopy is a well-established method for treatment of urinary stones but flexible ureteroscopes are expensive and fragile devices with a very limited lifetime. Since 2006 with the advent of digital flexible ureteroscopes a great evolution has occurred. The first single-use flexible ureteroscope was launched in 2011 and new models are coming to the market. The aim of this article is to review the characteristics of these devices, compare their results with the reusable devices and evaluate the cost-benefits of adopting single-use flexible ureteroscopes in developing countries. Materials and Methods: an extensive review of articles listed at PubMed and published between 2000 and 2021 was performed. Results: Single-use flexible ureteroscopes have a shaft with 65 to 68cm length and weight between 119 and 277g. Their deflection goes up to 300 degrees. Their stone-free rates vary between 60 and 95% which is comparable to reusable scopes and operative times ranges from 54 to 86 minutes which are lower when compared to reusable flexible scopes. Their costs vary between 800 and 3180 US dollars. Conclusion: single-use flexible ureteroscopes are lighter and have superior quality of image when compared to fiberoptic ones. There are no definite data showing a higher stone-free rate or less complications with the use of single-use flexible ureteroscopes. Each institution must perform a cost-benefit analysis before making the decision of adopting or not such devices depending on the local circumstances.

2.
Int Braz J Urol ; 48(3): 456-467, 2022.
Article in English | MEDLINE | ID: mdl-34786927

ABSTRACT

Flexible ureteroscopy is a well-established method for treatment of urinary stones but flexible ureteroscopes are expensive and fragile devices with a very limited lifetime. Since 2006 with the advent of digital flexible ureteroscopes a great evolution has occurred. The first single-use flexible ureteroscope was launched in 2011 and new models are coming to the market. The aim of this article is to review the characteristics of these devices, compare their results with the reusable devices and evaluate the cost-benefits of adopting single-use flexible ureteroscopes in developing countries. MATERIALS AND METHODS: an extensive review of articles listed at PubMed and published between 2000 and 2021 was performed. RESULTS: Single-use flexible ureteroscopes have a shaft with 65 to 68cm length and weight between 119 and 277g. Their deflection goes up to 300 degrees. Their stone-free rates vary between 60 and 95% which is comparable to reusable scopes and operative times ranges from 54 to 86 minutes which are lower when compared to reusable flexible scopes. Their costs vary between 800 and 3180 US dollars. CONCLUSION: single-use flexible ureteroscopes are lighter and have superior quality of image when compared to fiberoptic ones. There are no definite data showing a higher stone-free rate or less complications with the use of single-use flexible ureteroscopes. Each institution must perform a cost-benefit analysis before making the decision of adopting or not such devices depending on the local circumstances.


Subject(s)
Ureteroscopes , Urolithiasis , Developing Countries , Equipment Design , Humans , Ureteroscopy/methods
3.
Cent European J Urol ; 74(3): 459-463, 2021.
Article in English | MEDLINE | ID: mdl-34729238

ABSTRACT

INTRODUCTION: Given the fragility of reusable ureterorenoscopes, many single use instruments have appeared on the market. Unfortunately, reuse of these scopes occurs in undeveloped countries in order to cut costs. This raises safety concerns for the patient.The aim of this article was to macroscopically evaluate the changes that single use flexible ureterorenoscopes (su-fURS) suffer after a retrograde intrarenal surgery (RIRS), and to compare them to reusable fURS. MATERIAL AND METHODS: Pre and post-operative images of the instruments used in 23 RIRS were obtained. All the cases had renal calculi of the inferior calix between 10-15 mm, and all of them were treated with Holmium laser. The ureterorenoscopes used were: Storz® Flex X2, Storz® Flex XC, Pusen® 3022, OTU® Wiscope, AnQIng® Innovex and Boston Scientific® LithoVue. Qualitative comparisons of these were made. RESULTS: After su-fURS usage, significant damage was observed, especially on the distal tip. Deflection was not compromised. Reusable fURS did not sustain any damage after their use. CONCLUSIONS: fURS are delicate equipment, especially if they are of single use. The considerable damage sustained by single use scopes could mean that reuse of these instruments is dangerous and should be avoided.

4.
Int. braz. j. urol ; 41(4): 683-689, July-Aug. 2015. tab, graf
Article in English | LILACS | ID: lil-763067

ABSTRACT

ABSTRACTPurpose:To evaluate the clinical efficacy of flexible ureteroscope (F-URS) combined with holmium laser lithotripter in treating renal calculi in horseshoe kidney.Materials and Methods:From November 2010 to December 2013, the medical history and charts of sixteen patients (mean age 42.9±11.6 years, range 26-66 years), including 13 males and 3 females were analyzed retrospectively. Mean stone burden was 29±8 mm (range 17-42 mm2). Mean stone digitized surface area (DSA) was 321±94 mm2 (range 180-538 mm2). Under spinal anesthesia in a modified lithotomy position with the head down, rigid ureteroscope was placed firstly into the ureter to reach the level of the pelvis, a zebra guide wire was inserted and following the removal of the rigid ureteroscope, an ureteral access sheath was positioned along the guide wire, then passed the URF P-5 flexible ureteroscope into the renal cavities over the guidewire. After locating the stones, holmium laser lithotripsy was performed.Results:The average operative time was 92±16 minutes (range 74-127 min.). No major complications were encountered. Ten patients obtained stone-free status with one session, four obtained stone-free status after two sessions. Single session stone-free rate was 62.5%, overall stone-free rate was 87.5%. Two patients have small residual stones in the lower pole.Conclusions:F-URS combined with holmium laser lithotripter and nitinol basket, is safe and effective in dealing with moderate stone diameter (<30 mm) in HSKs with high clearance rates and low complication rates.


Subject(s)
Adult , Aged , Female , Humans , Male , Middle Aged , Fused Kidney/complications , Kidney Calculi/therapy , Ureteroscopy/instrumentation , Disease Management , Kidney Calculi/complications , Lasers, Solid-State/therapeutic use , Lithotripsy, Laser/classification , Lithotripsy, Laser , Operative Time , Retrospective Studies , Tomography, X-Ray Computed , Treatment Outcome , Ureteroscopes