ABSTRACT
ABSTRACT Purpose To characterize the most common presentation and clinical risk factors for artificial urinary sphincter (AUS) cuff erosion to distinguish the relative frequency of symptoms that should trigger further evaluation in these patients. Materials and Methods We retrospectively reviewed our tertiary center database to identify men who presented with AUS cuff erosion between 2007 - 2020. A similar cohort of men who underwent AUS placement without erosion were randomly selected from the same database for symptom comparison. Risk factors for cuff erosion - pelvic radiation, androgen deprivation therapy (ADT), high-grade prostate cancer (Gleason score ≥ 8) - were recorded for each patient. Presenting signs and symptoms of cuff erosion were grouped into three categories: obstructive symptoms, worsening incontinence, and localized scrotal inflammation (SI). Results Of 893 men who underwent AUS placement during the study interval, 61 (6.8%) sustained cuff erosion. Most erosion patients (40/61, 66%) presented with scrotal inflammatory changes including tenderness, erythema, and swelling. Fewer men reported obstructive symptoms (26/61, 43%) and worsening incontinence (21/61, 34%). Men with SI or obstructive symptoms presented significantly earlier than those with worsening incontinence (SI 14 ± 18 vs. obstructive symptoms 15 ± 16 vs. incontinence 37 ± 48 months after AUS insertion, p<0.01). Relative to the non-erosion control group (n=61), men who suffered erosion had a higher prevalence of pelvic radiation (71 vs. 49%, p=0.02). Conclusion AUS cuff erosion most commonly presents as SI symptoms. Obstructive voiding symptoms and worsening incontinence are also common. Any of these symptoms should prompt further investigation of cuff erosion.
ABSTRACT
PURPOSE: To characterize the most common presentation and clinical risk factors for artificial urinary sphincter (AUS) cuff erosion to distinguish the relative frequency of symptoms that should trigger further evaluation in these patients. MATERIALS AND METHODS: We retrospectively reviewed our tertiary center database to identify men who presented with AUS cuff erosion between 2007 - 2020. A similar cohort of men who underwent AUS placement without erosion were randomly selected from the same database for symptom comparison. Risk factors for cuff erosion - pelvic radiation, androgen deprivation therapy (ADT), high-grade prostate cancer (Gleason score ≥ 8) - were recorded for each patient. Presenting signs and symptoms of cuff erosion were grouped into three categories: obstructive symptoms, worsening incontinence, and localized scrotal inflammation (SI). RESULTS: Of 893 men who underwent AUS placement during the study interval, 61 (6.8%) sustained cuff erosion. Most erosion patients (40/61, 66%) presented with scrotal inflammatory changes including tenderness, erythema, and swelling. Fewer men reported obstructive symptoms (26/61, 43%) and worsening incontinence (21/61, 34%). Men with SI or obstructive symptoms presented significantly earlier than those with worsening incontinence (SI 14 ± 18 vs. obstructive symptoms 15 ± 16 vs. incontinence 37 ± 48 months after AUS insertion, p<0.01). Relative to the non-erosion control group (n=61), men who suffered erosion had a higher prevalence of pelvic radiation (71 vs. 49%, p=0.02). CONCLUSION: AUS cuff erosion most commonly presents as SI symptoms. Obstructive voiding symptoms and worsening incontinence are also common. Any of these symptoms should prompt further investigation of cuff erosion.
Subject(s)
Prostatic Neoplasms , Urinary Incontinence, Stress , Urinary Sphincter, Artificial , Androgen Antagonists , Humans , Male , Prostatic Neoplasms/etiology , Prostatic Neoplasms/radiotherapy , Retrospective Studies , Urinary Incontinence, Stress/etiology , Urinary Sphincter, Artificial/adverse effectsABSTRACT
INTRODUCTION: Bladder and urinary sphincter malfunctioning that results from some change in the central and/or peripheral nervous system is defined as neurogenic bladder. The urinary tract symptoms that can be related to its filling, emptying, or both have a significant impact on the quality of life of individuals. The present review was based on the document prepared for the public health system in Brazil as a treatment guidelines proposal. MATERIAL AND METHODS: Survey questions were structured as per PICO (Population, Intervention, Control, and Outcome). Search strategies were defined and performed in the MEDLINE/Pubmed, Embase, Epistemonikos and Google Scholar databases. The selection of articles followed the evidence hierarchy concept; evidence body was identified, and the quantitative study data were extracted. The quality of evidence and grade of recommendation were qualitatively assessed according to GRADE (Grading of Recommendations, Assessment, Development and Evaluations). RESULTS: A total of 2.707 articles were identified, with 49 of them being selected to compose the basis for this review. Neurogenic bladder treatments were classified according to their focus on filling or emptying symptoms and sub- classified in pharmacological and surgical treatments. CONCLUSION: Treatment guidelines are important tools for the public health system to promote the best practice when treating neurogenic bladder patients.
Subject(s)
Urinary Bladder, Neurogenic , Urinary Tract , Humans , Quality of Life , Surveys and Questionnaires , Urinary Bladder , Urinary Bladder, Neurogenic/therapyABSTRACT
ABSTRACT Purpose: Patient-reported history of pads per day (PPD) is widely recognized as a fundamental element of decision-making for anti-incontinence procedures. We hypothesize that SUI severity is often underestimated among men with moderate SUI. We sought to compare patient history of incontinence severity versus objective in-office physical examination findings. Materials and Methods: We retrospectively reviewed our single-surgeon male SUI surgical database from 2007-2019. We excluded patients with incomplete preoperative or postoperative data and those who reported either mild or severe SUI, thus having more straightforward surgical counseling. For men reported to have moderate SUI, we determined the frequency of upgrading SUI severity by recording the results of an in-office standing cough test (SCT) using the Male Stress Incontinence Grading Scale (MSIGS). The correlation of MSIGS with sling success rate was calculated. Failure was defined as >1 PPD usage or need for additional incontinence procedure. Results: Among 233 patients with reported moderate SUI (2-3 PPD), 89 (38%) had MSIGS 3-4 on SCT, indicating severe SUI. Among patients with 2-3 PPD preoperatively, sling success rates were significantly higher for patients with MSIGS 0-2 (76/116, 64%) compared to MSIGS 3-4 (6/18, 33%) (p <0.01). Conclusions: Many men with self-reported history of moderate SUI actually present severe SUI observed on SCT. The SCT is a useful tool to stratify moderate SUI patients to more accurately predict sling success.
Subject(s)
Humans , Male , Urinary Incontinence, Stress/surgery , Urinary Incontinence, Stress/diagnosis , Suburethral Slings , Prostatectomy , Retrospective Studies , Treatment Outcome , CoughABSTRACT
PURPOSE: Patient-reported history of pads per day (PPD) is widely recognized as a fundamental element of decision-making for anti-incontinence procedures. We hypothesize that SUI severity is often underestimated among men with moderate SUI. We sought to compare patient history of incontinence severity versus objective in-office physical examination findings. MATERIALS AND METHODS: We retrospectively reviewed our single-surgeon male SUI surgical database from 2007-2019. We excluded patients with incomplete preoperative or postoperative data and those who reported either mild or severe SUI, thus having more straightforward surgical counseling. For men reported to have moderate SUI, we determined the frequency of upgrading SUI severity by recording the results of an in-office standing cough test (SCT) using the Male Stress Incontinence Grading Scale (MSIGS). The correlation of MSIGS with sling success rate was calculated. Failure was defined as >1 PPD usage or need for additional incontinence procedure. RESULTS: Among 233 patients with reported moderate SUI (2-3 PPD), 89 (38%) had MSIGS 3-4 on SCT, indicating severe SUI. Among patients with 2-3 PPD preoperatively, sling success rates were significantly higher for patients with MSIGS 0-2 (76/116, 64%) compared to MSIGS 3-4 (6/18, 33%) (p <0.01). CONCLUSIONS: Many men with self-reported history of moderate SUI actually present severe SUI observed on SCT. The SCT is a useful tool to stratify moderate SUI patients to more accurately predict sling success.
Subject(s)
Suburethral Slings , Urinary Incontinence, Stress , Cough , Humans , Male , Prostatectomy , Retrospective Studies , Treatment Outcome , Urinary Incontinence, Stress/diagnosis , Urinary Incontinence, Stress/surgeryABSTRACT
OBJECTIVE: To investigate the effect of perioperative complications involving artificial urinary sphincter (AUS) implantation on rates of explantation and continence as well as health-related quality of life (HRQOL). MATERIALS AND METHODS: Inclusion criteria encompassed non-neurogenic, moderate-to-severe stress urinary incontinence (SUI) post radical prostatectomy and primary implantation of an AUS performed by a high-volume surgeon (>100 previous implantations). Reporting complications followed the validated Clavien-Dindo scale and Martin criteria. HRQOL was assessed by the validated IQOL score, continence by the validated ICIQ-SF score. Statistical analysis included Chi (2) test, Mann-Whitney-U test, and multivariate regression models (p<0.05). RESULTS: 105 patients from 5 centers met the inclusion criteria. After a median follow-up of 38 months, explantation rates were 27.6% with a continence rate of 48.4%. In the age-adjusted multivariate analysis, perioperative urinary tract infection was confirmed as an independent predictor of postoperative explantation rates [OR 24.28, 95% CI 2.81-209.77, p=0.004). Salvage implantation (OR 0.114, 95% CI 0.02-0.67, p=0.016) and non-prostatectomy related incontinence (OR 0.104, 95% CI 0.02-0.74, p=0.023) were independent predictors for worse continence outcomes. Low visual analogue scale scores (OR 9.999, 95% CI 1,42-70.25, p=0.021) and ICIQ-SF scores, respectively (OR 0.674, 95% CI 0.51-0.88, p=0.004) were independent predictors for increased HRQOL outcomes. Perioperative complications did not significantly impact on continence and HRQOL outcomes. CONCLUSION: Findings show postoperative infections adversely affect device survival after AUS implantation. However, if explantation can be avoided, the comparative long-term functional results and HRQOL outcomes are similar between patients with or without perioperative complications.
Subject(s)
Urinary Incontinence, Stress , Urinary Sphincter, Artificial , Aged , Humans , Male , Middle Aged , Prostatectomy/adverse effects , Quality of Life , Treatment Outcome , Urinary Incontinence, Stress/etiology , Urinary Incontinence, Stress/surgeryABSTRACT
ABSTRACT Objective To investigate the effect of perioperative complications involving artificial urinary sphincter (AUS) implantation on rates of explantation and continence as well as health-related quality of life (HRQOL). Materials and methods Inclusion criteria encompassed non-neurogenic, moderate-to-severe stress urinary incontinence (SUI) post radical prostatectomy and primary implantation of an AUS performed by a high-volume surgeon (>100 previous implantations). Reporting complications followed the validated Clavien-Dindo scale and Martin criteria. HRQOL was assessed by the validated IQOL score, continence by the validated ICIQ-SF score. Statistical analysis included Chi (2) test, Mann-Whitney-U test, and multivariate regression models (p <0.05). Results 105 patients from 5 centers met the inclusion criteria. After a median follow-up of 38 months, explantation rates were 27.6% with a continence rate of 48.4%. In the age-adjusted multivariate analysis, perioperative urinary tract infection was confirmed as an independent predictor of postoperative explantation rates [OR 24.28, 95% CI 2.81-209.77, p=0.004). Salvage implantation (OR 0.114, 95% CI 0.02-0.67, p=0.016) and non-prostatectomy related incontinence (OR 0.104, 95% CI 0.02-0.74, p=0.023) were independent predictors for worse continence outcomes. Low visual analogue scale scores (OR 9.999, 95% CI 1,42-70.25, p=0.021) and ICIQ-SF scores, respectively (OR 0.674, 95% CI 0.51-0.88, p=0.004) were independent predictors for increased HRQOL outcomes. Perioperative complications did not significantly impact on continence and HRQOL outcomes. Conclusion Findings show postoperative infections adversely affect device survival after AUS implantation. However, if explantation can be avoided, the comparative long-term functional results and HRQOL outcomes are similar between patients with or without perioperative complications.
Subject(s)
Humans , Male , Aged , Urinary Incontinence, Stress/surgery , Urinary Incontinence, Stress/etiology , Urinary Sphincter, Artificial , Prostatectomy/adverse effects , Quality of Life , Treatment Outcome , Middle AgedABSTRACT
OBJECTIVE: To evaluate the subjective and objective outcomes of MacroplastiqueR (MPQ) in women with stress urinary incontinence (SUI) secondary to intrinsic sphincter deficiency (ISD). MATERIALS AND METHODS: Following Institutional Review Board (IRB) approval, charts of non-neurogenic women with SUI secondary to ISD who underwent MPQ injection and had 6 months minimum follow-up were reviewed from a prospectively maintained database. Patients were divided into 3 groups: Naive (Group I), Prior Anti-Incontinence Surgery (Group II), and combined Prior Bulking Agent and Anti-Incontinence Surgery (Group III). Data collected included SUI self-report, Urogenital Distress Inventory (UDI-6) Question 3, and VAS Quality of Life (QoL) Questionnaire scores at baseline and in follow-up. Three-dimensional ultrasound (3DUS) evaluated volume/confi guration of MPQ. Success was defi ned after the last MPQ injection as a UDI-6 Question 3 score of 0 (dry) or 1, and no reoperation for SUI. RESULTS: From 2011-2017, 106 of 142 women met study criteria. At a median follow-up of 20 months (mean=26 months; range: 6-71), success rate was 41% for Group I, 40% for Group II, and 65% for Group III (p = 0.22). QoL scores were signifi cantly improved over baseline in all groups. There was no signifi cant difference in clinical outcome between the asymmetrical and symmetrical group on 3DUS. The completely dry rate was highest in Group III at 29%, compared to 4% for Group I and 15% for Group II (p = 0.05). CONCLUSION: MacroplastiqueR improved subjective and objective outcome measures for SUI secondary to ISD as both a primary and secondary treatment option in women.
Subject(s)
Dimethylpolysiloxanes/therapeutic use , Urethral Diseases/complications , Urinary Incontinence, Stress/etiology , Urinary Incontinence, Stress/surgery , Adult , Aged , Aged, 80 and over , Collagen/therapeutic use , Female , Humans , Injections , Middle Aged , Prospective Studies , Quality of Life , Reoperation , Reproducibility of Results , Surveys and Questionnaires , Time Factors , Treatment OutcomeABSTRACT
ABSTRACT Objective To evaluate the subjective and objective outcomes of Macroplastique® (MPQ) in women with stress urinary incontinence (SUI) secondary to intrinsic sphincter deficiency (ISD). Materials and Methods Following Institutional Review Board (IRB) approval, charts of non-neurogenic women with SUI secondary to ISD who underwent MPQ injection and had 6 months minimum follow-up were reviewed from a prospectively maintained database. Patients were divided into 3 groups: Naïve (Group I), Prior Anti-Incontinence Surgery (Group II), and combined Prior Bulking Agent and Anti-Incontinence Surgery (Group III). Data collected included SUI self-report, Urogenital Distress Inventory (UDI-6) Question 3, and VAS Quality of Life (QoL) Questionnaire scores at baseline and in follow-up. Three-dimensional ultrasound (3DUS) evaluated volume/configuration of MPQ. Success was defined after the last MPQ injection as a UDI-6 Question 3 score of 0 (dry) or 1, and no reoperation for SUI. Results From 2011-2017, 106 of 142 women met study criteria. At a median follow-up of 20 months (mean=26 months; range: 6-71), success rate was 41% for Group I, 40% for Group II, and 65% for Group III (p = 0.22). QoL scores were significantly improved over baseline in all groups. There was no significant difference in clinical outcome between the asymmetrical and symmetrical group on 3DUS. The completely dry rate was highest in Group III at 29%, compared to 4% for Group I and 15% for Group II (p = 0.05). Conclusion Macroplastique® improved subjective and objective outcome measures for SUI secondary to ISD as both a primary and secondary treatment option in women.
Subject(s)
Humans , Female , Adult , Aged , Aged, 80 and over , Urethral Diseases/complications , Urinary Incontinence, Stress/surgery , Urinary Incontinence, Stress/etiology , Dimethylpolysiloxanes/therapeutic use , Quality of Life , Reoperation , Time Factors , Prospective Studies , Surveys and Questionnaires , Reproducibility of Results , Collagen/therapeutic use , Treatment Outcome , Injections , Middle AgedABSTRACT
PURPOSE: The objective of the present study is to test the efficiency and practicality of a new artificial sphincter "BR - SL - AS - 904" in the control of urinary incontinence in post - PR patients and to evaluate their complications. PATIENTS AND METHODS: Fifteen patients with incontinence after one year of radical prostatectomy were included prospectively. All patients underwent artificial urethral sphincter (AUS) implant "BR - SL - AS - 904" according to established technique. Independent variables such as free urinary flow, PAD weight test, ICIQ - SF score and urinary symptoms through the IPSS score were compared in different follow-up moments. RESULTS: Patients submitted to AUS implantation did not present trans - operative or post - operative complications related to the surgical act such as: infection, hematoma, erosion or urinary retention. Device was inert to the body during the follow-up, showing an excellent adaptation of the patients, besides the easy handling. The mean age was 68.20 years 40% of the patients had systemic arterial hypertension, 6.7% diabetes mellitus, 6.7% were hypertensive and diabetic, 13.4% were hypertensive, had diabetes and hypercholesterolemia and 26.7% patients had no comorbidities. It was evidenced that the urinary flow peak during the follow-up remained stable. Decreased averages and median PAD weight test were 135.19 to 75.72 and 106.00 to 23.50, respectively. The IPSS score decreased and the quality of life increased (12.33 to 3.40 and 2.50 to 3.20 respectively). The ICQF - SF questionnaire score also showed a decrease, ranging from 16, 71 to 7.33. CONCLUSION: The artificial sphincter implant "BR - SL - AS 904" was reproducible, safe and effective in the control of urinary incontinence in post - PR patients.
Subject(s)
Prostatectomy/adverse effects , Prosthesis Implantation/methods , Urinary Incontinence/surgery , Urinary Sphincter, Artificial , Aged , Case-Control Studies , Humans , Male , Prospective Studies , Quality of Life , Treatment Outcome , Urinary Incontinence/etiologyABSTRACT
ABSTRACT Purpose We present a novel AUS implantation technique using a single perineal incision for single device placement or in combination with an inflatable penile prosthesis (IPP). Urinary and sexual dysfunction following the management of prostate cancer has a significant impact on the quality of life of our patients. While there are marginal changes in the prosthetic devices, we strive to reduce post-operative morbidity while maximizing efficacy. Materials and Methods We retrospectively reviewed the outcomes of 6 patients who underwent single perineal incision placement of a virgin AUS in 2014, 3 with simultaneous IPP placement. In all cases, the pressure regulating balloons (PRB) were placed in a high sub-muscular ectopic position and the pumps were placed into a sub-dartos pouch through the perineal incision, which was also validated using a cadaveric model. Results The mean patient age was 61 (SD, 7.5 years) with mean body mass index of 31 (SD, 5.9). The average pre-operative pad usage was 7.7 (SD 1.63) pads per day. The mean follow-up was 13.9 months (SD 9.45). Four out of the six patients reported utilizing ≤1 pad daily at follow-up. The one patient who was not initially dry required downsizing of his cuff to 3.5cm; the remaining patient was lost to follow-up. There were no identifiable perioperative or post-operative complications. Conclusions We present our initial report of using a single perineal incision for AUS implantation with a validated sub-dartos pump location, which is safe and effective for implantation of an AUS as a single or double implantation in well-selected patients.
Subject(s)
Humans , Male , Urinary Incontinence, Stress/surgery , Urinary Sphincter, Artificial , Prosthesis Implantation/methods , Cadaver , Feasibility Studies , Retrospective Studies , Follow-Up Studies , Treatment Outcome , Penile Implantation/methods , Middle AgedABSTRACT
Case Hypothesis: Surgical removal is the standard treatment for artificial sphincter extrusion. However in some specific situations is possible to maintain the prosthesis with good results. CASE REPORT: We report a 60 years old patient presenting sphincter pump extrusion one month after artificial urinary sphincter (AUS) AMS 800™ placement for treating post-radical prostatectomy urinary incontinence (PRPUI). He also had a penile prosthesis implant one year before that was replaced in the same surgery the sphincter was implanted. As patient refused sphincter removal and there were no signals of active infection he was treated by extensive surgical washing with antibiotics and antiseptics. Pump was repositioned in the opposite side of the scrotum. Patient had good evolution with sphincter activation 50 days later. After 10 months of follow up, patient is socially continent and having regular sexual intercourse. Savage surgery may be an option in select cases of artificial sphincter extrusion. Promising future implications: Like in some patients with penile prosthesis some patients with artificial sphincter extrusion can be treated without removing the device. This may be a line of research about conservative treatment of artificial sphincter complications.
Subject(s)
Postoperative Complications/surgery , Prosthesis Failure , Salvage Therapy/methods , Urinary Sphincter, Artificial/adverse effects , Humans , Male , Middle Aged , Reproducibility of Results , Treatment Outcome , Urinary Incontinence/surgeryABSTRACT
OBJECTIVES: Report the long-term outcomes of the AMS 800 artificial sphincer (AS) for the treatment post-prostatectomy incontinence (PPI) in a single center in Brazil. MATERIALS AND METHODS: Clinical data from patients who underwent the procedure were retrieved from the medical records of individuals with more than 1 year of follow-up from May 2001 to January 2016. Continence status (number of pads that was used), complications (erosion or extrusion, urethral atrophy, and infection), malfunctions, and need for secondary implantation were evaluated. The relationship between complications and prior or subsequent radiation therapy (RT) was also examined. RESULTS: From May 2001 to January 2016, 121 consecutive patients underwent AS implantation for PPI at an oncological referral center in Brazil. At the last visit, the AS remained implanted in 106 patients (87.6%), who reported adequate continence status (maximum of 1 pad/day). Eight-two subjects (67.8%) claimed not to be using pads on a regular basis at the final visit (completely dry). Revision occurred in 24 patients (19.8%).Radiation therapy (RT) for prostate cancer following radical prostatectomy was used in 47 patients before or after AS placement. Twelve patients with a history of RT had urethral erosion compared with 3 men without RT (p=0.004). CONCLUSION: Considering our outcomes, we conclude that AS implantation yields satisfactory results for the treatment of PPI and should remain the standard procedure for these patients. Radiation therapy is a risk factor for complication.
Subject(s)
Postoperative Complications/therapy , Prostatectomy/adverse effects , Prosthesis Implantation/methods , Urinary Incontinence/therapy , Urinary Sphincter, Artificial , Brazil , Humans , Male , Postoperative Complications/etiology , Radiotherapy Dosage , Retrospective Studies , Risk Factors , Urethra/surgery , Urinary Incontinence/etiology , UrodynamicsABSTRACT
PURPOSE: We present a novel AUS implantation technique using a single perineal incision for single device placement or in combination with an inflatable penile prosthesis (IPP). Urinary and sexual dysfunction following the management of prostate cancer has a significant impact on the quality of life of our patients. While there are marginal changes in the prosthetic devices, we strive to reduce post-operative morbidity while maximizing efficacy. MATERIALS AND METHODS: We retrospectively reviewed the outcomes of 6 patients who underwent single perineal incision placement of a virgin AUS in 2014, 3 with simultaneous IPP placement. In all cases, the pressure regulating balloons (PRB) were placed in a high sub-muscular ectopic position and the pumps were placed into a sub-dartos pouch through the perineal incision, which was also validated using a cadaveric model. RESULTS: The mean patient age was 61 (SD, 7.5 years) with mean body mass index of 31 (SD, 5.9). The average pre-operative pad usage was 7.7 (SD 1.63) pads per day. The mean follow-up was 13.9 months (SD 9.45). Four out of the six patients reported utilizing ≤1 pad daily at follow-up. The one patient who was not initially dry required downsizing of his cuff to 3.5cm; the remaining patient was lost to follow-up. There were no identifiable perioperative or post-operative complications. CONCLUSIONS: We present our initial report of using a single perineal incision for AUS implantation with a validated sub-dartos pump location, which is safe and effective for implantation of an AUS as a single or double implantation in well-selected patients.
Subject(s)
Prosthesis Implantation/methods , Urinary Incontinence, Stress/surgery , Urinary Sphincter, Artificial , Cadaver , Feasibility Studies , Follow-Up Studies , Humans , Male , Middle Aged , Penile Implantation/methods , Retrospective Studies , Treatment OutcomeABSTRACT
ABSTRACT Objective To compare outcomes for single urethral cuff downsizing versus tandem cuff placement during artificial urinary sphincter (AUS) revision for urethral atrophy. Materials and Methods We identified 1778 AUS surgeries performed at our institution from 1990-2014. Of these, 406 were first AUS revisions, including 69 revisions for urethral atrophy. Multiple clinical and surgical variables were evaluated for potential association with device outcomes following revision, including surgical revision strategy (downsizing a single urethral cuff versus placing tandem urethral cuffs). Results Of the 69 revision surgeries for urethral atrophy at our institution, 56 (82%) were tandem cuff placements, 12 (18%) were single cuff downsizings and one was relocation of a single cuff. When comparing tandem cuff placements and single cuff downsizings, the cohorts were similar with regard to age (p=0.98), body-mass index (p=0.95), prior pelvic radiation exposure (p=0.73) and length of follow-up (p=0.12). Notably, there was no difference in 3-year overall device survival compared between single cuff and tandem cuff revisions (60% versus 76%, p=0.94). Likewise, no significant difference was identified for tandem cuff placement (ref. single cuff) when evaluating the risk of any tertiary surgery (HR 0.95, 95% CI 0.32-4.12, p=0.94) or urethral erosion/device infection following revision (HR 0.79, 95% CI 0.20-5.22, p=0.77). Conclusions There was no significant difference in overall device survival in patients undergoing single cuff downsizing or tandem cuff placement during AUS revision for urethral atrophy.
Subject(s)
Humans , Male , Female , Aged , Aged, 80 and over , Reoperation/methods , Urethra/pathology , Urinary Incontinence, Stress/surgery , Urinary Sphincter, Artificial , Prosthesis Implantation/methods , Prosthesis Design , Atrophy , Time Factors , Urethra/surgery , Prosthesis Failure , Retrospective Studies , Risk Factors , Follow-Up Studies , Treatment Outcome , Statistics, NonparametricABSTRACT
This study aimed to retrospectively evaluate a cohort of patients with prostate cancer and persistent urinary incontinence after radical prostatectomy. From January 2004 to December 2015, eighty-six individuals were identified to have received an AUS implant, provided by a private nonprofit HMO operating in Belo Horizonte, Brazil. On total, there were 91 AUS implants, with a median interval between radical prostatectomy and AUS implant of 3.6 years (IQR 1.9 to 5.5). The rate of AUS cumulative survival, after a median follow-up of 4.1 years (IQR 1.7-7.2 years), was 44% (n=40). The median survival of AUS implants was 2.9 years (IQR 0.5-7.9 years). Thirty-seven AUS implants (40.7%) resulted in grade III surgical complications. There were 5 deaths at 2.1, 4.7, 5.7, 5.7 and 6.5 years of follow-up, but none due to causes directly associated to the AUS implant. Persistent severe incontinence was documented in 14 (15.3%) additional patients. From the 51 AUS implants which resulted in grade III surgical complications or persistent severe incontinence, 24 (47.1%) underwent surgical revisions. Explantation of the sphincter or its components was observed in 6 cases (25.0%). Mechanical failure, described as fluid loss and/or inability to recycle the AUS device, was observed in 4 devices (16.7%). In conclusion, although AUS implants are recommended as the gold-standard treatment of severe urinary incontinence after prostatectomy, the observed high rates of malfunction and grade III adverse events are a matter of concern warranting further assessment on the safety and efficacy of these devices.
Subject(s)
Prostatectomy/adverse effects , Prostatectomy/methods , Prostatic Neoplasms/surgery , Urinary Incontinence/etiology , Urinary Incontinence/surgery , Urinary Sphincter, Artificial , Aged , Aged, 80 and over , Humans , Male , Middle Aged , Postoperative Complications , Prosthesis Failure , Prosthesis Implantation/adverse effects , Prosthesis Implantation/methods , Reproducibility of Results , Retrospective Studies , Time Factors , Treatment Outcome , Urinary Sphincter, Artificial/economicsABSTRACT
OBJECTIVE: To compare outcomes for single urethral cuff downsizing versus tandem cuff placement during artificial urinary sphincter (AUS) revision for urethral atrophy. MATERIALS AND METHODS: We identified 1778 AUS surgeries performed at our institution from 1990-2014. Of these, 406 were first AUS revisions, including 69 revisions for urethral atrophy. Multiple clinical and surgical variables were evaluated for potential association with device outcomes following revision, including surgical revision strategy (downsizing a single urethral cuff versus placing tandem urethral cuffs). RESULTS: Of the 69 revision surgeries for urethral atrophy at our institution, 56 (82%) were tandem cuff placements, 12 (18%) were single cuff downsizings and one was relocation of a single cuff. When comparing tandem cuff placements and single cuff downsizings, the cohorts were similar with regard to age (p=0.98), body-mass index (p=0.95), prior pelvic radiation exposure (p=0.73) and length of follow-up (p=0.12). Notably, there was no difference in 3-year overall device survival compared between single cuff and tandem cuff revisions (60% versus 76%, p=0.94). Likewise, no significant difference was identified for tandem cuff placement (ref. single cuff) when evaluating the risk of any tertiary surgery (HR 0.95, 95% CI 0.32-4.12, p=0.94) or urethral erosion/device infection following revision (HR 0.79, 95% CI 0.20-5.22, p=0.77). CONCLUSIONS: There was no significant difference in overall device survival in patients undergoing single cuff downsizing or tandem cuff placement during AUS revision for urethral atrophy.
Subject(s)
Prosthesis Implantation/methods , Reoperation/methods , Urethra/pathology , Urinary Incontinence, Stress/surgery , Urinary Sphincter, Artificial , Aged , Aged, 80 and over , Atrophy , Female , Follow-Up Studies , Humans , Male , Prosthesis Design , Prosthesis Failure , Retrospective Studies , Risk Factors , Statistics, Nonparametric , Time Factors , Treatment Outcome , Urethra/surgeryABSTRACT
OBJECTIVE: To evaluate the effect of neuronal nitric oxide synthase on the striated urethral sphincter and the urinary bladder. MATERIALS AND METHODS: A coaxial catheter was implanted in the proximal urethra and another one in the bladder of female rats, which were anesthetized with subcutaneous injection of urethane. The urethral pressure with saline continuous infusion and bladder isovolumetric pressure were simultaneously recorded. Two groups of rats were formed. In group I, an intrathecal catheter was implanted on the day of the experiment at the L6-S1 level of the spinal cord; in group II, an intracerebroventricular cannula was placed 5-6 days before the experiment. RESULTS: It was verified that the group treated with S-methyl-L-thio-citrulline, via intrathecal pathway, showed complete or partial inhibition of the urethral sphincter relaxation and total inhibition of the micturition reflexes. The urethral sphincter and the detrusor functions were recovered after L-Arginine administration. When S-methyl-Lthio-citrulline was administered via intracerebroventricular injection, there was a significant increase of urethral sphincter tonus while preserving the sphincter relaxation and the detrusor contractions, at similar levels as before the use of the drugs. Nevertheless there was normalization of the urethral tonus when L-Arginine was applied. CONCLUSIONS: The results indicate that, in female rats anaesthetized with urethane, the nNOS inhibitor administrated through the intrathecal route inhibits urethral sphincter relaxation, while intracerebroventricular injection increases the sphincter tonus, without changing bladder function. These changes were reverted by L-Arginine administration. These findings suggest that the urethral sphincter and detrusor muscle function is modulated by nitric oxide.
Subject(s)
Citrulline/analogs & derivatives , Enzyme Inhibitors/pharmacology , Nitric Oxide Synthase Type I/pharmacology , Thiourea/analogs & derivatives , Urethra/drug effects , Urinary Bladder/drug effects , Urination/drug effects , Anesthetics, Intravenous , Animals , Arginine/pharmacology , Citrulline/pharmacology , Female , Injections, Spinal , Muscle Contraction/drug effects , Muscle Contraction/physiology , Pressure , Rats, Wistar , Reference Values , Thiourea/pharmacology , Time Factors , Urethane/pharmacology , Urethra/physiology , Urinary Bladder/physiology , Urination/physiologyABSTRACT
Purpose: To evaluate the long term outcomes of permanent Memotherm urethral stent in the treatment of recurrent bulbar urethral stricture. Materials and Methods: Twenty patients who underwent permanent Memotherm urethral stent implantation due to recurrent bulbar urethral stricture following previous unsuccessful surgical procedure from 1996 to 2002 were included in the study. Long-term outcomes of the patients were evaluated. Results: The overall success rate was 87.5% at the end of the tenth year. There was discomfort in implantation area in eight patients about 1 month following the procedure. These patients were treated with alpha-blocker and anti-inflammatory drugs. Stone formation was observed at the urethral stent implantation area in two patients. Post-void dripping has been observed in 15 patients up to the postoperative 3rd month. Stress urinary incontinence was observed in a patient with a 1-year follow-up. Partial stent migration was observed in two patients. None of the patients experienced pain during erection. Conclusion: Memotherm urethral stent is a minimal invasive surgical procedure which can be safely and effectively used in patients with recurrent urethral stricture. .