Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 315
Filter
1.
Nurs Open ; 11(7): e2177, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38967938

ABSTRACT

AIM: To develop and psychometrically test an instrument to assess nurses' evidence-based knowledge and self-efficacy regarding insertion and management of venous access devices (short peripheral catheter (SPC), long peripheral catheter/midline (LPC) and PICC) and the management of totally implantable central venous catheter (Port) in adult patients. DESIGN: Multicenter cross-sectional observational study with questionnaire development and psychometric testing (validity and reliability). METHODS: An evidence-based instrument was developed including a 34-item knowledge section and an 81-item self-efficacy section including four device-specific parts. Nineteen experts evaluated content validity. A pilot study was conducted with 86 nurses. Difficulty and discrimination indices were calculated for knowledge items. Confirmatory factor analyses tested the dimensionality of the self-efficacy section according to the development model. Construct validity was tested through known group validity. Reliability was evaluated through Cronbach's alpha coefficient for unidimensional scales and omega coefficients for multidimensional scales. RESULTS: Content validity indices and results from the pilot study were excellent with all the item-content validity indices >0.78 and scale-content validity index ranging from 0.96 to 0.99. The survey was completed by 425 nurses. Difficulty and discrimination indices for knowledge items were acceptable with most items (58.8%) showing desirable difficulty and most items (58.8%) with excellent (35.3%) or good (23.5%) discrimination power, and appropriate to the content. The dimensionality of the model posited for self-efficacy was confirmed with adequate fit indices (e.g., comparative fit index range 0.984-0.996, root mean square error of approximation range 0.054-0.073). Construct validity was determined and reliability was excellent with alpha values ranging from 0.843 to 0.946 and omega coefficients ranging from 0.833 to 0.933. Therefore, a valid and reliable tool based on updated guidelines is made available to evaluate nurses' competencies for venous access insertion and management.


Subject(s)
Psychometrics , Self Efficacy , Humans , Surveys and Questionnaires , Cross-Sectional Studies , Female , Adult , Male , Reproducibility of Results , Psychometrics/instrumentation , Psychometrics/standards , Pilot Projects , Clinical Competence/standards , Nurses/psychology , Health Knowledge, Attitudes, Practice , Middle Aged , Catheterization, Central Venous/nursing , Catheterization, Central Venous/standards , Vascular Access Devices
2.
J Pediatr Nurs ; 78: 112-117, 2024 Jun 24.
Article in English | MEDLINE | ID: mdl-38917612

ABSTRACT

BACKGROUND: The PiccPed® health application was developed to support clinical decision-making in peripherally inserted central catheter (PICC) management. We aimed to evaluate its impact on nurses' knowledge regarding the prevention of PICC-associated adverse events in pediatrics and neonatology. METHODS: A quasi-experimental, pre-post intervention study, was conducted with a dependent/paired sample of pediatric and neonatal nurses from two tertiary hospitals in South Brazil. Data were collected from October 2022 to January 2023 across three phases: pre-, intervention (use of the PiccPed®) and post-test. Study outcomes were a knowledge test (15 questions) of evidence-based PICC maintenance procedures, and PiccPed® app time spent and screens used. RESULTS: A total of 56 nurses completed the study. The post-test mean score was significantly higher (12/15; standard deviation (SD) 1.9) in comparison with the pre-test (mean 9/15; SD 2.2). The change in scores was significantly higher for nurses without postgraduate qualifications, in comparison to those with (Mean Difference 1.26; p = 0.039). Each minute using the app resulted in a significant increase of 0.04 points (95% confidence interval 0.01-0.08; p = 0.014) on the mean post-test score (10.94 points). CONCLUSION: The research demonstrated that PiccPed® enhances nurses' learning regarding the prevention of adverse events associated with PICC maintenance in pediatrics and neonatology. APPLICATION TO PRACTICE: The app can be safely and effectively used for training and continuing education of nurses who care for children and neonates with PICCs.

3.
Am J Infect Control ; 2024 Jun 04.
Article in English | MEDLINE | ID: mdl-38844143

ABSTRACT

BACKGROUND: Peripheral intravenous catheters (PIVs) are the most frequently used invasive device in hospitalized patients. These devices are not benign and are associated with complications. However, clinician awareness of them is variable and poorly understood. METHODS: We conducted a prospective, multicenter, observational point prevalence study to assess awareness of PIV presence among clinicians caring for hospitalized patients in 4 hospitals between May 2018 and February 2019 located in Michigan, USA. We first assessed patients for the presence of a PIV then interviewed their providers. Differences in awareness by provider type were assessed via χ² tests; P < .05 was considered statistically significant. Analyses were performed on Stata MP v16. RESULTS: A total of 1,385 patients and 4,003 providers were interviewed. Nurses had the greatest awareness of overall PIV presence, 98.6%, while attendings were correct 88.1% of the time. Nurses were more likely to correctly assess PIV presence and exact location than physicians (67.7% vs <30% for all others). Awareness of PIV presence did not significantly vary in patients on contact precautions or those receiving infusions. CONCLUSIONS: Given the ubiquity of PIVs and known complications, methods to increase awareness to ensure appropriate care and removal are necessary.

4.
Neonatology ; : 1-6, 2024 Jun 21.
Article in English | MEDLINE | ID: mdl-38934171

ABSTRACT

INTRODUCTION: The umbilical venous catheter is a vital access device in neonatal intensive care units for preterm and critically ill infants. Correct positioning is crucial, as malpositioning can lead to severe complications. According to international guidelines, the position of the umbilical venous catheter tip must be assessed in real time; traditionally, the catheter is visualized with a thoracoabdominal X-ray, but one of the most effective and safest methods is therefore real-time ultrasound. METHODS: This study compares real-time ultrasound and traditional X-ray methods for assessing umbilical venous catheter tip location in 461 cases. The rate of tip malposition was analyzed retrospectively. The secondary aim was to assess indwelling time of umbilical venous catheters and reasons of removal. RESULTS: Real-time ultrasound tip location, found to be more reliable and efficient, demonstrated a significantly lower incidence of primary malpositioning compared to X-ray assessments (9.6 vs. 75.9%). The study also highlighted the association of real-time ultrasound with reduced catheter manipulation, fewer radiographs, and higher indwelling times of umbilical venous catheter. The multiple logistic regression showed a high probability of the central safe position of the umbilical venous catheter tip using real-time ultrasound tip location (odds ratio 29.5, 95% confidence interval: 17.4-49.4). CONCLUSION: The findings support the adoption of real-time ultrasound in clinical settings to enhance umbilical venous catheter placement accuracy and minimize associated risks. A minimal training investment is needed to attain the proficiency to visualize the umbilical venous catheters, offering a substantial advantage in terms of both cost-effectiveness for the procedure and enhanced patient safety.

5.
SAGE Open Med Case Rep ; 12: 2050313X241255014, 2024.
Article in English | MEDLINE | ID: mdl-38773988

ABSTRACT

Radial artery is mostly used for arterial cannulation because of its location, collateral circulation, and less complications. Dorsalis pedis artery can be an alternative for arterial cannulation in difficult radial or brachial arteries cannulation situations as it is mostly overlooked. We present a case of a 45-year-old female planned for supratentorial craniotomy for excision of meningioma. After induction of anesthesia, the invasive access couldn't be attained after multiple attempts under ultrasound guidance by five senior anesthesiologists. The surgery was abandoned, and the patient awakened. The case was rescheduled after 2 days. The new anesthesia team attained the arterial access in the right dorsalis pedis artery and the central venous access in the right internal jugular vein in the first attempt. No complications were noted post-operatively. The dorsalis pedis artery can be safely used for arterial cannulation when radial artery cannulation is not possible.

6.
J Vasc Access ; : 11297298241254633, 2024 May 27.
Article in English | MEDLINE | ID: mdl-38800992

ABSTRACT

BACKGROUND: Ultrasound guidance can reduce the number of attempts to gain peripheral IV access while improving the success rate and satisfaction in patients with difficult IV access. Education and simulation are effective tools for improving the skills and knowledge related to ultrasound-guided peripheral IV access. Ultrasound phantom models allow for skill development without the risk of patient harm. METHODS: Twenty-nine registered nurses and nurse practitioners were recruited for education and simulation regarding ultrasound-guided peripheral IV (USGPIV) placement. Participants completed a survey evaluating the efficacy of the phantom models in addition to pre- and post-intervention confidence, perceived competence, knowledge surveys, and a Directly Observed Procedural Skills Evaluation (DOPSE). The intervention included an educational PowerPoint and open practice session using the phantom models. RESULTS: Statistically significant improvements were found in participants' confidence (p < 0.001; 95% CI: 5.287, 9.499; d = 1.31), perceived competence (p < 0.001; 95% CI: 1.231, 2.742; d = 1.20), knowledge (p < 0.001; 95% CI: 1.079, 2.163; d = 1.47), and skills (p < 0.001; 95% CI: 2.499; 5.501; d = 1.29). Participants improved in maintaining needle visualization (p < 0.001; 95% CI: 0.272, 0.9; d = 0.79) and decreasing their cannulation attempts (0.045; 95% CI: 0.013, 1.022; d = 0.48). Participants with no and novice experience saw statistically significant improvement across all categories (p < 0.02) compared to those with intermediate, advanced, or expert experience with ultrasound. 96.5% of participants could perform ultrasound-guided peripheral IV cannulation independently or with indirect supervision following the intervention. CONCLUSIONS: At $36.52 per model, the self-assembled ultrasound phantom models provided a cost-effective and sustainable solution to teaching ultrasound-guided peripheral IV cannulations. Education and simulation for ultrasound-guided peripheral vascular access may benefit individuals with no or novice ultrasound experience.

7.
J Adv Nurs ; 2024 May 02.
Article in English | MEDLINE | ID: mdl-38698552

ABSTRACT

BACKGROUND: Optimal selection of vascular access devices is based on multiple factors and is the first strategy to reduce vascular access device-related complications. This process is dependent on behavioural and human factors. The COM-B (Capability, Opportunity, Motivation, Behaviour) model was used as a theoretical framework to organize the findings of this systematic review. METHODS/AIMS: To synthesize the evidence on determinants shaping the optimal selection of vascular access devices, using the COM-B behavioural model as the theoretical framework. DESIGN: Systematic review of studies which explore decision-making at the time of selecting vascular access devices. DATA SOURCES: The Medline, Web of Science, Scopus and EbscoHost databases were interrogated to extract manuscripts published up to 31 December 2021, in English or Spanish. RESULTS: Among 16 studies included in the review, 8/16 (50%) focused on physical capability, 8/16 (50%) psychological capability, 15/16 (94%) physical opportunity, 12/16 (75%) social opportunity, 1/16 (6%) reflective motivation and 0/16 (0%) automatic motivation. This distribution represents a large gap in terms of interpersonal and motivational influences and cultural and social environments. Specialist teams (teams created for the insertion or maintenance of vascular access devices) are core for the optimal selection of vascular access devices (75% physical capability, 62% psychological capability, 80% physical opportunity and 100% social opportunity). CONCLUSION: Specialist teams predominantly lead all actions undertaken towards the optimal selection of vascular access devices. These actions primarily centre on assessing opportunity and capability, often overlooking motivational influences and social environments. IMPLICATIONS FOR THE PROFESSION AND/OR PATIENT CARE: A more implementation-focused professional approach could decrease inequity among patients and complications associated with vascular access devices. IMPACT: Optimal selection of vascular access devices is the primary strategy in mitigating complications associated with these devices. There is a significant disparity between interpersonal and motivational influences and the cultural and social environments. Furthermore, specialized teams play a pivotal role in facilitating the optimal selection of vascular access devices. The study can benefit institutions concerned about vascular access devices and their complications. REPORTING METHOD: This review followed the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. PATIENT OR PUBLIC CONTRIBUTION: No Patient or Public Contribution. WHAT DOES THIS ARTICLE CONTRIBUTE TO THE WIDER GLOBAL CLINICAL COMMUNITY?: Optimal selection of vascular devices remains a growing yet unresolved issue with costly clinical and patient experience impact. Interventions to improve the optimal selection of vascular devices have focused on training, education, algorithms and implementation of specialist vascular teams; alas, these approaches do not seem to have substantially addressed the problem. Specialist vascular teams should evolve and pivot towards leading the implementation of quality improvement interventions, optimizing resource use and enhancing their role.

8.
Front Public Health ; 12: 1375431, 2024.
Article in English | MEDLINE | ID: mdl-38694974

ABSTRACT

Introduction: The Spanish Emergency Medical Services, according to the model we know today, were formed during the 80s and 90s of the 20th century. The Health Emergency Service (EMS), 061 La Rioja, began to assist the population of La Rioja in November 1999. An essential part of the mission of the SES is the provision of care and the transfer of critical patients using advanced life support unit (ALSU) techniques. In daily practice, out-of-hospital emergency services are faced with situations in which they must deal with the care of serious or critically ill patients, in which the possibility of being able to channel peripheral vascular access as part of ALSU quickly may be difficult or impossible. In these cases, cannulation of intraosseous (IO) vascular access may be the key to early and adequate care. Aim: This study aimed to determine the incidence and epidemiology use of IO vascular access in SES 061 La Rioja during the year 2022. Matherial and methods: We performed observational retrospective cross-sectional studies conducted in 2022. It included a population of 4.364 possible patients as a total of interventions in the community of La Rioja in that year. Results: A total of 0.66% of patients showed a clinical situation that required the establishment of IO vascular access to enable out-of-hospital stabilization; this objective was achieved in 41.3%. A total of 26.1% of patients who presented with cardiorespiratory arrest (CA) were stabilized, while 100% presented with shock and severe trauma. Discussion: IO vascular access provides a suitable route for out-of-hospital stabilization of critically ill patients when peripheral vascular access is difficult or impossible.


Subject(s)
Infusions, Intraosseous , Humans , Cross-Sectional Studies , Retrospective Studies , Female , Male , Middle Aged , Aged , Infusions, Intraosseous/statistics & numerical data , Spain , Adult , Emergency Medical Services/statistics & numerical data , Emergency Service, Hospital/statistics & numerical data , Aged, 80 and over , Critical Illness
9.
Interv Neuroradiol ; : 15910199241245601, 2024 Apr 09.
Article in English | MEDLINE | ID: mdl-38592015

ABSTRACT

BACKGROUND: Endovascular treatment devices require compatible guide catheters to navigate complex vessels and anatomy. The Fubuki XF Long Sheath guide catheter (Fubuki XF) was developed with a 0.090-inch internal diameter with hydrophilic coating, an atraumatic rounded tip, and enhanced trackability and support with gradual shaft transition zones. METHODS: We retrospectively analyzed a prospectively maintained database of neuroendovascular patients treated using Fubuki XF at our center (July 2022─May 2023). Baseline/procedural characteristics were collected. Outcomes of interest included technical success (procedure completion with Fubuki XF without alternative guide catheter use) and peri-procedural complications. RESULTS: This study included 60 patients (43.3% [26/60] female; mean age: 69.6 ± 9.7) presenting with stenosis (45.0% [27/60]), unruptured aneurysms (31.7% [19/60]), ruptured aneurysm (1.7% [1/60]), arteriovenous fistula (5.0% [3/60]), arteriovenous malformation (3.3% [2/60]), chronic subdural hematoma (3.3% [2/60]), stroke/emboli (6.7% [4/60]), vasospasm (1.7% [1/60]), or carotid web (5.0% [1/60]). Fubuki XF was used to deliver endovascular treatment devices for stenting (43.3% [26/60]), flow diversion (23.3% [14/60]), embolization (11.7% [7/60]), coiling (10.0% [6/60]), balloon angioplasty (10.0% [6/60]), and mechanical thrombectomy (1.7% [1/60]). The Fubuki XF tip was placed in the internal carotid artery in 38.3% (23/60) of cases. Technical success was achieved in all cases. One V1 non-flow-limiting dissection (not related to Fubuki XF) and one failed closure occurred (1.7% [1/60] each). No iatrogenic strokes or intraprocedural ruptures occurred. CONCLUSION: We used Fubuki XF to safely and effectively deliver a variety of compatible neuroendovascular devices. Fubuki XF was stable in all cases and locations, and there were no device-related complications or dissections.

10.
J Vasc Access ; : 11297298241246092, 2024 Apr 24.
Article in English | MEDLINE | ID: mdl-38655780

ABSTRACT

The main objective of this umbrella review is to synthesise available evidence from systematic reviews on the effectiveness of interventions for the management of occlusions in central venous access devices. CVADS have been extensively utilised among the critically ill since the 1950s however have also been linked to an increase in catheter complications. CVAD occlusion can occur in 14%-36% of patients within 1-2 years of catheter placement and is a longstanding complication. Umbrella methodology was applied to review five healthcare databases. Databases were searched for publications from 2009 and 2022 and electronic keywords searches were conducted. The authors searched for reviews that reported on any intervention to prevent, maintain or manage patency of the central venous access devices within an acute care setting. Of the 278 articles identified from the initial search a total of 11 articles were identified. This umbrella review concluded that education enhances patient outcomes and decreases occlusion rates. Further studies are required to explore occlusion reduction strategies in relation to flushing and locking.

11.
Res Pract Thromb Haemost ; 8(3): 102391, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38660454

ABSTRACT

Background: Managing central venous catheters in patients with neoplasms is challenging, and peripherally inserted central catheter PORT (PICC-PORT) has emerged as a promising option for safety and efficacy. However, understanding the clinical progression of catheter-related thrombosis (CRT) in cancer patients with central venous catheters remains limited, especially in certain neoplasm types associated with a higher risk of venous thrombosis. Objectives: This study aims to assess the effectiveness of ultrasound-guided management in detecting and treating asymptomatic CRT in cancer patients with PICC. Methods: In this prospective cohort study of 120 patients with solid neoplasms receiving chemotherapy, we investigated the incidence of isolated upper-extremity superficial vein thrombosis, upper-extremity deep vein thrombosis, and fibrin sheath formation through ultrasound follow-up at 30 and 90 days after catheter insertion. We analyzed risk factors associated with CRT and compared incidence rates between PICC-PORT and traditional PICC. Results: Among the cohort, 69 patients (57.5%) had high-risk thromboembolic neoplasm, and 31 cases (25.8%) of CRT were observed, mostly within 30 days, with only 7 cases (22.6%) showing symptoms. Traditional PICC use (odds ratio, 5.86; 95% CI, 1.14-30) and high-risk thromboembolic neoplasm (odds ratio, 4.46; 95% CI, 1.26-15.81) were identified as independent risk factors for CRT. Conclusion: The majority of CRT present asymptomatically within the first 30 days of venous catheter insertion in patients with solid neoplasms. Ultrasound follow-up is valuable for detecting asymptomatic CRT. The risk of CRT was lower with PICC-PORT than with PICC. Additionally, the risk of CRT was found to be higher in patients with high-risk thromboembolic neoplasms. It is crucial for larger studies to confirm the utility of treating asymptomatic thromboses and isolated superficial thrombosis.

12.
J Vasc Access ; : 11297298241236405, 2024 Mar 20.
Article in English | MEDLINE | ID: mdl-38506816

ABSTRACT

BACKGROUND: Peripheral arterial catheters (PACs), and their associated complications, are common in the pediatric intensive care unit (PICU). Accidental catheter displacement and non-functional PACs are the most common complications, and this may be related to inadequate catheter securement. There is mixed guidance on the best way to secure PACs to prevent complications. The authors hypothesized that sutures would not be associated with a decreased risk of malfunction or accidental removal. METHODS: This was a single center retrospective cohort study at a quaternary-care PICU. PICU patients with a peripheral arterial catheter placed in the PICU from 7/2020 to 1/2023 were included. The primary outcome was unplanned PAC removal. A univariate and multivariate Cox proportional hazards regression analysis was performed, using patient weight, sedation, paralytic, and role of the proceduralist as covariates. The secondary outcome was survival probability. A log-rank test was used to compare survival curves. RESULTS: Of 761 PACs that met inclusion criteria in 437 unique patients, 599 were sutured (78.7%) and 162 were un-sutured (21.3%). In 257 cases (33.8%), the PAC had an unplanned removal. Among all PACs, the median duration of PAC placement was 5.3 days (IQR 2.1-10.5 days). There was an unplanned removal rate of 42.2% (68) in the un-sutured group and 31.4% (188) in the sutured group (p < 0.001). In multivariable analysis, sutured PACs were also associated with a lower rate of unplanned removal (hazard ratio, 0.59; 95% CI, 0.44-0.78). Use of continuous sedation was also associated with an increased risk of unplanned removal of PACs (hazard ratio, 1.54; 95% CI, 1.10-2.16). There was a 50% survival probability at 13.3 days for un-sutured PACs and 23.7 days for sutured PACs. CONCLUSIONS: Suturing is associated with fewer unplanned removals and longer catheter survival, compared to un-sutured PACs in pediatric patients.

13.
Cureus ; 16(1): e52385, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38361669

ABSTRACT

INTRODUCTION: Venous access for hemodialysis (HD) makes patients more susceptible to transient bacteremia, predisposing them to the development of infective endocarditis (IE). Among the risk factors observed in this population are temporary access to HD, hypoalbuminemia, diabetes mellitus, female gender, anemia, and colonization by methicillin-resistant Staphylococcus aureus (MRSA). METHODOLOGY: A retrospective case-control study with a one-to-two ratio was carried out on patients with chronic kidney disease (CKD) undergoing renal replacement therapy with at least one vascular access for HD at Complejo Hospitalario Dr. Arnulfo Arias Madrid (CHDrAAM) from 2010 to 2020. Sociodemographic variables, past medical history, and data on current HD were studied. The odds ratio (OR) and adjusted odds ratio (aOR) were calculated for the collected variables. RESULTS: No statistically significant differences between the groups were observed in sociodemographic variables. In terms of past medical history, the cases showed a predominance of coronary disease (47.6% vs 4.8%; OR: 37.27), valvular disease (23.8% vs 0%), and heart failure (33.3% vs 4.8%; OR: 10). In the cases, the use of a temporary catheter was more prevalent (61.9% vs 33.3%; OR: 3.25), and subclavian access was more frequently recorded (28.6% vs 2.4%; OR: 14.4). A short duration of venous access (<30 days) was found in a greater proportion of cases (23.8% vs 4.8%; OR: 6.25). The main pathogen isolated was S. aureus (33.3%), and the most affected valve was the aortic valve (59.1%). Fever was found in 100% of the reported cases, and up to 47.6% presented with a recent murmur. DISCUSSION: Similar to previous studies conducted in other countries, we identified a history of pre-existing valve disease, the use of a temporary catheter, and recent venous access as risk factors. Contrary to what has been reported in the literature, this study did not find female sex, diabetes mellitus, and hypoalbuminemia as risks. CONCLUSION: Factors such as a history of coronary artery disease, heart failure, preexisting valvular disease, the use of a temporary catheter, subclavian venous access, and short duration of venous access (<30 days) were identified as risk factors for the development of IE in patients with CKD on HD.

14.
Cureus ; 16(1): e52231, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38352095

ABSTRACT

PURPOSE: The central venous port (CVP) is widely used for intravenous chemotherapy (IVC) in adult patients because of its lower infection rates and easier management than that of a central venous catheter. However, the feasibility and safety of the CVP for IVC in infants remain unknown. This study evaluated the usefulness of CVP for IVC in infants with retinoblastoma. METHODS: The usefulness of CVP was retrospectively evaluated using technical success rates, the safety of CVP placement, and postoperative procedure-related complications in 18 infants with retinoblastoma. This study was conducted at the National Cancer Center Hospital, Chuo-Ku, Tokyo, Japan. RESULTS: The technical success rate was 100% (18/18) without any procedure-related complications. The sum duration of CVP implantation was 12,836 days (mean: 713 ± 453 days, range: 10-1,639 days). Postoperative complications were observed in two cases; one was a port reversal after 20 days, which was reversed by incisional surgery, and another was a catheter-related bloodstream infection after eight days, resulting in CVP removal. The total incidence of CVP-related infections was 5.6% (1/18) and 0.08/1000 catheter days. No other CVP-related complications were noted. CONCLUSION: The use of the CVP for IVC in infants with retinoblastoma was feasible with few complications.

15.
J Vasc Access ; : 11297298241230109, 2024 Feb 19.
Article in English | MEDLINE | ID: mdl-38372249

ABSTRACT

INTRODUCTION: Ultrasound-guided peripheral IV catheter (USGIV) insertion is as an effective procedure to establish access in patients with difficult intravenous access (DIVA), a condition frequently encountered in the Emergency Department (ED). This study describes a DIVA quality improvement program focusing on rapid identification of DIVA patients and emergency nurse USGIV training and evaluates its impact on overall frequency of USGIV use and process measures related to quality of patient care. METHODS: This is a retrospective cohort study of patients over 18 years of age, presenting to a single, tertiary care hospital between September 1, 2018 and September 30, 2020. Difference-in-difference analysis was used to compare ED process measures pre- and post-implementation of the DIVA Program, and multivariate logistic regression was used to identify associations between patient characteristics and difficult IV access. RESULTS: The frequency of ED encounters associated with USGIV placement more than doubled post-implementation of the DIVA Program, rising from 606 to 1323. There were improved covariate-adjusted time estimates of core ED process measures for encounters associated with USGIV placement post-implementation, including decreases in time to CT with contrast from 4.8 h (95% CI = 4.4-5.2) to 4.1 h (95% CI = 3.8-4.4), pain medications from 2.4 h (95% CI = 2.1-2.6) to 1.8 h (95% CI = 1.6-2.0), IV antibiotics from 3.0 h (95% CI = 2.4-3.7) to 2.1 h (95% CI = 1.5-2.6), and ED length of stay from 6.4 h (95% CI = 6.2-6.6) to 6.0 h (95% CI = 5.9-6.2). CONCLUSION: A nurse-focused quality improvement program focused on teaching and promoting USGIV as a modality for managing difficult IV access was associated with increases in USGIV placement and improvements in core process measures related to quality of patient care.

16.
Radiol Case Rep ; 19(5): 1692-1696, 2024 May.
Article in English | MEDLINE | ID: mdl-38384698

ABSTRACT

It is impossible to predict underlying anomalies in acute large vessel occlusion and it could be a problem when performing mechanical thrombectomy (MT). We report a case of MT for occlusion of the fenestrated middle cerebral artery (MCA) M1 segment. A 49-year-old woman presented to our hospital with dysarthria and left hemiparesis. Acute ischemic stroke due to right occluded MCA was diagnosed. During performing emergent MT, a part of the M1 segment was revealed to be slit-shaped by digital subtraction angiography, suggesting a fenestrated MCA. The aspiration catheter could not be advanced through the narrow limb of the fenestration, and the distal thrombus was retrieved using a stent retriever, additionally. Postoperatively, the patient's symptoms improved without complications. When occlusion of the fenestrated MCA is suspected, it is necessary to consider converting the strategy from an aspiration catheter alone to the combined use of a stent retriever.

17.
Metas enferm ; 27(1): 61-67, Febr. 2024. tab
Article in Spanish | IBECS | ID: ibc-230208

ABSTRACT

Objetivo: describir la evolución del modelo de atención del acceso vascular por un equipo de terapia infusional enfermero referente (ETI) y sus resultados en la seguridad vinculados al acceso vascular central de inserción periférica (PICC) en pacientes oncohematológicos. Métodos: estudio observacional en una cohorte retrospectiva de 3.423 pacientes oncohematológicos a los cuales se les indicó un PICC ambulatoriamente durante 2012-2021. Variables: modelo de atención, motivo de la indicación, método de comprobación de la colocación del acceso, complicaciones del acceso vascular. Recogida de información mediante datos primarios del registro de acceso vascular y registro clínico de la historia informatizada ESPOQ2©. Análisis descriptivo paquete estadístico IBM SPSS® V.23.0 . Resultados: la creación de un equipo referente de terapia infusional incrementó la capacidad de colocación de catéteres, pasando de 98 (2013) a 768 (2021). La indicación del PICC pasó del 45,80% por instauración de quimioterapia mediante bomba de infusión domiciliaria (2016) al 93,70% por indicación por fármaco irritante o vesicante (2021) (p< 0,001). La introducción de la técnica ecoguiada y método electro-intracavitario de control de punta disminuyeron las complicaciones por flebitis mecánicas y la radiación por comprobación de catéter (p< 0,001). Conclusiones: los modelos de atención con equipos de terapia infusional referentes consolidados incrementan la seguridad del paciente oncológico portador de acceso vascular PICC.(AU)


Objective: to describe the evolution of the vascular access care model led by a nurse infusion therapy (ETI) team and its safety results associated with peripherally inserted central vascular access (PICC) in oncohematology patients. Methods: descriptive observational study in a retrospective cohort in 3,423 oncohaematological patients who were indicated for a PICC on an outpatient basis during 2012 to 2021. Variables: Care model, reason for the indication, access placement verification method, vascular access complications. Data collection using primary data from the vascular access registry and clinical registry of the ESPOQ2© computerized history. Descriptive analysis using IBM® SPSS® Statistics V.23.0. Results: infusional teams' reference increased the capacity to place catheters, going from 98 (2013) to 768 (2021). The indication for the PICC went from 45.80% due to initiation of chemotherapy home infusion (2016) to 93.70% due to an indication for an irritant or vesicant drug (2021) (p< 0.001). The introduction of the ultrasound-guided technique and electro-intracavitary method of tip control decreased complications due to mechanical phlebitis and radiation due to catheter verification (p< 0.001). Conclusions: care models with consolidated reference infusion therapy teams increase the safety of cancer patients with PICC vascular access.(AU)


Subject(s)
Humans , Vascular Access Devices , Medical Oncology , Hematology , Quality of Health Care , Patient Safety
18.
J Vasc Access ; : 11297298231222052, 2024 Jan 05.
Article in English | MEDLINE | ID: mdl-38183179

ABSTRACT

BACKGROUND: A major contributor to peripheral intravenous catheter (PIVC) failure may be related to PIVC movement within the vein which is associated with vein wall damage. The magnitude of PIVC movement against the vein wall has not previously been quantified. This study aimed to examine PIVC movement within the vein when minor forces were applied to the PIVC. METHODS: This was a prospective, pilot trial including healthy volunteers in an outpatient research laboratory. The primary objective was to examine the in movement (millimeters) of the PIVC using ultrasound with external pull forces (4, 5, and 6 lbs; 1.8, 2.3, and 2.7 kg, respectively) applied to the PIVC in random order. RESULTS: Participants (N = 11) were aged 40.36 ± 16.10 years with 54.55% being Male. Mean ± SD PIVC movement for 4, 5, and 6 lbs of force was 4.65 ± 1.88, 3.88 ± 2.28, and 5.25 ± 2.06 mm, respectively. There was substantial PIVC movement when a force was applied to the PIVC, but no statistically significant difference between 4, 5, and 6 lb forces (p > 0.05). CONCLUSION: When external pull forces were applied to the PIVC, substantial PIVC movement within the vein occurred in a healthy population. Strategies that reduce PIVC movement and/or remove or limit external pull forces from the PIVC are needed. Future studies on hospitalized patients are warranted to quantify vein wall injury and PIVC failure due to PIVC movement from various pull forces.

19.
Crit Care Nurs Clin North Am ; 36(1): 111-118, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38296369

ABSTRACT

Neonates admitted to the neonatal intensive care unit (NICU) are a unique population who most often begin life acutely or critically ill. Venous access is required by most acutely/critically ill neonates, especially those born preterm. Access is required for implementing management strategies such as stabilization, medications, fluids, nutrition, and transfusion of blood products. However, achieving and maintaining venous access in these neonates can be difficult, especially in preterm infants due to a myriad of contributing factors. Peripheral intravenous (PIV) catheters and peripherally inserted central catheters (PICC) are 2 common vascular access approaches used in the NICU and have traditionally been the most studied in the neonatal literature. Both options offer advantages and disadvantages. An alternative to PIVs and PICCs is the midline peripheral catheter (MPC), which in the literature may also be referred to as extended dwell peripheral intravenous catheters. Depending on the intended use, the MPC offers a venous access approach between a PIV and PICC. Usage of MPCs in the NICU is slowly increasing with the limited published evidence suggesting they are viable option when considering the need for vascular access. The purpose of this article is to present the advantages and disadvantages of MPCs as an alternative approach for venous access in neonates when appropriate.


Subject(s)
Catheter-Related Infections , Catheterization, Central Venous , Infant , Infant, Newborn , Humans , Intensive Care Units, Neonatal , Infant, Premature , Catheterization, Central Venous/adverse effects , Critical Illness , Catheter-Related Infections/epidemiology , Retrospective Studies , Catheters
20.
Br J Nurs ; 33(2): S34-S41, 2024 Jan 25.
Article in English | MEDLINE | ID: mdl-38271041

ABSTRACT

HIGHLIGHTS: What we know about the topic: Recommendations for the use of vascular access care bundles to reduce infection are followed for different devices. The risk of arterial catheter-related infection is comparable with short-term, non-cuffed central venous catheters. There are practice concerns for clinicians inserting and caring for peripheral arterial catheters. What this paper adds: The selected studies had a theme of decreased infection after using bundled strategies for all devices. Few studies addressed use of bundles for care of peripheral arterial catheters. High-quality research should be performed about using care bundles for insertion and care of arterial catheters. INTRODUCTION: A scoping review of the literature was performed. AIMS/OBJECTIVES: To find information on the use of care bundles for care of arterial, central, and peripherally inserted venous catheters. METHODS: Data was extracted by 2 independent researchers using standardized methodology. RESULTS: Results of 84 studies included 2 (2.4%) randomized controlled trials, 38 (45.2%) observational studies, 29 (34.5%) quality projects, and 15 (17.9%) reviews. Populations had more adults than pediatric patients. All studies had the most prominent theme of decreased infection in all devices after using bundle strategies. DISCUSSION AND CONCLUSIONS: The mapping of available evidence strongly supports the use of care bundles to reduce infection in the care of all intravascular devices. However, deficiencies regarding practice concerns about insertion and care of arterial catheters highlight areas for future research with the aim to eliminate the gap in the evidence of studies of care bundles for peripheral arterial catheters.


Subject(s)
Catheter-Related Infections , Catheterization, Central Venous , Catheterization, Peripheral , Central Venous Catheters , Patient Care Bundles , Vascular Access Devices , Adult , Humans , Child , Catheters, Indwelling , Catheter-Related Infections/prevention & control
SELECTION OF CITATIONS
SEARCH DETAIL
...