Adv Funct Mater ; 34(7)2024 Feb.
Article in English | MEDLINE | ID: mdl-39257639

ABSTRACT

The availability of grafts to replace small-diameter arteries remains an unmet clinical need. Here, the validated methodology is reported for a novel hybrid tissue-engineered vascular graft that aims to match the natural structure of small-size arteries. The blood vessel mimic (BVM) comprises an internal conduit of co-electrospun gelatin and polycaprolactone (PCL) nanofibers (corresponding to the tunica intima of an artery), reinforced by an additional layer of PCL aligned fibers (the internal elastic membrane). Endothelial cells are deposited onto the luminal surface using a rotative bioreactor. A bioprinting system extrudes two concentric cell-laden hydrogel layers containing respectively vascular smooth muscle cells and pericytes to create the tunica media and adventitia. The semi-automated cellularization process reduces the production and maturation time to 6 days. After the evaluation of mechanical properties, cellular viability, hemocompatibility, and suturability, the BVM is successfully implanted in the left pulmonary artery of swine. Here, the BVM showed good hemostatic properties, capability to withstand blood pressure, and patency at 5 weeks post-implantation. These promising data open a new avenue to developing an artery-like product for reconstructing small-diameter blood vessels.

3.
Biomater Adv ; 165: 214018, 2024 Dec.
Article in English | MEDLINE | ID: mdl-39226677

ABSTRACT

A high vascular patency was realized in the bulk or surface heparinized small-diameter in situ tissue-engineered vascular grafts (TEVGs) via a rabbit carotid artery replacement model in our previous studies. Those surface heparinized TEVGs could reduce the occurrence of aneurysms, but with a low level of the remodeled elastin, whereas those bulk heparinized TEVGs displayed a faster degradation and an increasing occurrence of aneurysms, but with a high level of the regenerated elastin. To combine the advantages of the bulk and surface graft heparinization to boost the remodeling of elastin and defer the occurrence of aneurysms, a coaxial electro-spinning technique was used to fabricate a kind of small-diameter core/shell fibrous structural in situ TEVGs with a faster degradable poly(lactic-co-glycolic acid) (PLGA) as a core layer and a relatively lower degradable poly(ε-caprolactone) (PCL) as a shell layer followed by the surface heparinization. The in vitro mechanical performance and enzymatic degradation tests revealed the resulting PLGA@PCL-Hep in situ TEVGs possessing not only a faster degradation rate, but also the mechanical properties comparable to those of human saphenous veins. After implanted in the rat abdominal aorta for 12 months, the good endothelialization, low inflammation, and no calcification were evidenced. Furthermore, the neointima layer of regenerated new blood vessels was basically constructed with a well-organized arrangement of elastin and collagen proteins. The results showed the great potential of these in situ TEVGs to be used as a novel type of long-term small-diameter vascular grafts.


Subject(s)
Blood Vessel Prosthesis , Tissue Engineering , Animals , Rats , Tissue Engineering/methods , Polylactic Acid-Polyglycolic Acid Copolymer/chemistry , Polyesters/chemistry , Aorta, Abdominal/pathology , Blood Vessel Prosthesis Implantation/methods , Elastin/metabolism , Male , Tissue Scaffolds/chemistry , Rats, Sprague-Dawley , Humans , Rabbits , Materials Testing
4.
Bioact Mater ; 41: 127-136, 2024 Nov.
Article in English | MEDLINE | ID: mdl-39131628

ABSTRACT

Current gold standard for the replacement of small-diameter blood vessel (ID < 4 mm) is still to utilize the autologous vessels of patients due to the limitations of small-diameter vascular grafts (SDVG) on weak endothelialization, intimal hyperplasia and low patency. Herein, we create the SDVG with the tailored endothelialization by applying the engineered endothelial cell vesicles to camouflaging vascular grafts for the enhancement of vascular remodeling. The engineered endothelial cell vesicles were modified with azide groups (ECVs-N3) through metabolic glycoengineering to precisely link the vascular graft made of PCL-DBCO via click chemistry, and thus fabricating ECVG (ECVs-N3 modified SDVG), which assists inhibition of platelet adhesion and activation, promotion of ECs adhesion and enhancement of anti-inflammation. Furthermore, In vivo single-cell transcriptome analysis revealed that the proportion of ECs in the cell composition of ECVG surpassed that of PCL, and the tailored endothelialization enabled to convert endothelial cells (ECs) into some specific ECs clusters. One of the specific cluster, Endo_C5 cluster, was only detected in ECVG. Consequently, our study integrates the engineered membrane vesicles of ECVs-N3 from native ECs for tailored endothelialization on SDVG by circumventing the limitations of living cells, and paves a new way to construct the alternative endothelialization in vessel remodeling following injury.

5.
Bioengineering (Basel) ; 11(7)2024 Jul 10.
Article in English | MEDLINE | ID: mdl-39061783

ABSTRACT

Small-diameter vascular grafts (SDVGs) are severely lacking in clinical settings. Therefore, our study investigates a new source of biological vessels-bovine and porcine decellularized intercostal arteries (DIAs)-as potential SDVGs. We utilized a combination of SDS and Triton X-100 to perfuse the DIAs, establishing two different time protocols. The results show that perfusing with 1% concentrations of each decellularizing agent for 48 h yields DIAs with excellent biocompatibility and mechanical properties. The porcine decellularized intercostal arteries (PDIAs) we obtained had a length of approximately 14 cm and a diameter of about 1.5 mm, while the bovine decellularized intercostal arteries (BDIAs) were about 29 cm long with a diameter of approximately 2.2 mm. Although the lengths and diameters of both the PDIAs and BDIAs are suited for coronary artery bypass grafting (CABG), as the typical diameter of autologous arteries used in CABG is about 2 mm and the grafts required are at least 10 cm long, our research indicates that BDIAs possess more ideal mechanical characteristics for CABG than PDIAs, showing significant potential. Further enhancements may be necessary to address their limited hemocompatibility.

6.
ACS Appl Mater Interfaces ; 16(31): 40515-40530, 2024 Aug 07.
Article in English | MEDLINE | ID: mdl-39044622

ABSTRACT

Sensitive biomaterials subjected to surface modification require delicate methods to preserve their structures and key properties. These include collagen-sealed polyester vascular prostheses. For their functionalization, coating with polycatecholamines (PCAs) can be used. PCAs change some important biological properties of biomaterials, e.g., hydrophilicity, bioactivity, antibacterial activity, and drug binding. The coating process can be stimulated by oxidants, organic solvents, or process conditions. However, these factors may change the properties of the PCA layer and the matrix itself. In this work, collagen-sealed vascular grafts were functionalized with a poly(l-DOPA) (PLD) layer using novel seawater-inspired ion combination as an accelerator, compared to the sodium periodate, Cu2+/H2O2 mixture, and accelerator-free reference methods. Then, poly(l-DOPA) was used as the interface for antibiotic binding. The coated prostheses were characterized (SEM, FIB-SEM, FTIR, UV/vis), and their important functional parameters (mechanical, antioxidant, hemolytic, and prothrombotic properties, bioactivity, stability in human blood and simulated body fluid (SBF), antibiotic binding, release, and antibacterial activity) were compared. It was found that although sodium periodate increased the strength and drug-binding capacity of the prosthesis, it also increased the blood hemolysis risk. Cu2+/H2O2 destabilized the mechanical properties of the coating and the graft. The seawater-inspired ion-accelerated method was efficient, stable, and matrix- and human blood-friendly, and it stimulated hydroxyapatite formation on the prosthesis surface. The results lead to the conclusion that selection of the PCA formation accelerator should be based on a careful analysis of the biological properties of medical devices. They also suggest that the ion-accelerated method of PLD coating on medical devices may be highly effective and safer than the oxidant-accelerated coating method.


Subject(s)
Anti-Bacterial Agents , Blood Vessel Prosthesis , Coated Materials, Biocompatible , Collagen , Copper , Hydrogen Peroxide , Copper/chemistry , Copper/pharmacology , Coated Materials, Biocompatible/chemistry , Coated Materials, Biocompatible/pharmacology , Humans , Hydrogen Peroxide/chemistry , Anti-Bacterial Agents/chemistry , Anti-Bacterial Agents/pharmacology , Collagen/chemistry
7.
ACS Appl Mater Interfaces ; 16(31): 40787-40804, 2024 Aug 07.
Article in English | MEDLINE | ID: mdl-39072379

ABSTRACT

Vascular defects caused by trauma or vascular diseases can significantly impact normal blood circulation, resulting in serious health complications. Vascular grafts have evolved as a popular approach for vascular reconstruction with promising outcomes. However, four of the greatest challenges for successful application of small-diameter vascular grafts are (1) postoperative anti-infection, (2) preventing thrombosis formation, (3) utilizing the inflammatory response to the graft to induce tissue regeneration and repair, and (4) noninvasive monitoring of the scaffold and integration. The present study demonstrated a basic fibroblast growth factor (bFGF) and oleic acid dispersed Ag@Fe3O4 core-shell nanowires (OA-Ag@Fe3O4 CSNWs) codecorated poly(lactic acid) (PLA)/gelatin (Gel) multifunctional electrospun vascular grafts (bAPG). The Ag@Fe3O4 CSNWs have sustained Ag+ release and exceptional photothermal capabilities to effectively suppress bacterial infections both in vitro and in vivo, noninvasive magnetic resonance imaging (MRI) modality to monitor the position of the graft, and antiplatelet adhesion properties to promise long-term patency. The gradually released bFGF from the bAPG scaffold promotes the M2 macrophage polarization and enhances the recruitment of macrophages, endothelial cells (ECs) and fibroblast cells. This significant regulation of diverse cell behavior has been proven to be beneficial to vascular repair and regeneration both in vitro and in vivo. Therefore, this study supplies a method to prepare multifunctional vascular-repair materials and is expected to represent a significant guidance and reference to the development of biomaterials for vascular tissue engineering.


Subject(s)
Fibroblast Growth Factor 2 , Gelatin , Nanofibers , Nanowires , Polyesters , Silver , Tissue Scaffolds , Polyesters/chemistry , Gelatin/chemistry , Fibroblast Growth Factor 2/chemistry , Fibroblast Growth Factor 2/pharmacology , Animals , Silver/chemistry , Nanofibers/chemistry , Nanowires/chemistry , Tissue Scaffolds/chemistry , Humans , Blood Vessel Prosthesis , Mice , Human Umbilical Vein Endothelial Cells
8.
J Cardiothorac Surg ; 19(1): 470, 2024 Jul 27.
Article in English | MEDLINE | ID: mdl-39068409

ABSTRACT

Non-iatrogenic trauma of the iliac artery is rarely reported but is always life-threatening. In this report, we describe the case of a child with complete transection and partial disappearance of the iliac artery caused by bicycle handlebar impalement. He experienced catastrophic hemorrhage, malignant arrhythmia, and difficulty in exploring transected vessel stumps. Aggressive infusion, blood transfusion in time, and pediatric vascular characteristics help delay the deterioration during anesthesia induction. Eventually he was successfully rescued by performing interventional balloon occlusion and open revascularization after more than 7 h post-trauma. A series of interventions and precautionary methods may benefit such severely injured patients; thus, these methods should be highlighted.


Subject(s)
Iliac Artery , Humans , Iliac Artery/surgery , Iliac Artery/injuries , Male , Child , Bicycling/injuries , Balloon Occlusion/methods , Vascular System Injuries/surgery , Vascular System Injuries/etiology , Vascular Surgical Procedures/methods , Wounds, Nonpenetrating/surgery
9.
Front Bioeng Biotechnol ; 12: 1411680, 2024.
Article in English | MEDLINE | ID: mdl-38988863

ABSTRACT

Introduction: The development of next-generation tissue-engineered medical devices such as tissue-engineered vascular grafts (TEVGs) is a leading trend in translational medicine. Microscopic examination is an indispensable part of animal experimentation, and histopathological analysis of regenerated tissue is crucial for assessing the outcomes of implanted medical devices. However, the objective quantification of regenerated tissues can be challenging due to their unusual and complex architecture. To address these challenges, research and development of advanced ML-driven tools for performing adequate histological analysis appears to be an extremely promising direction. Methods: We compiled a dataset of 104 representative whole slide images (WSIs) of TEVGs which were collected after a 6-month implantation into the sheep carotid artery. The histological examination aimed to analyze the patterns of vascular tissue regeneration in TEVGs in situ. Having performed an automated slicing of these WSIs by the Entropy Masker algorithm, we filtered and then manually annotated 1,401 patches to identify 9 histological features: arteriole lumen, arteriole media, arteriole adventitia, venule lumen, venule wall, capillary lumen, capillary wall, immune cells, and nerve trunks. To segment and quantify these features, we rigorously tuned and evaluated the performance of six deep learning models (U-Net, LinkNet, FPN, PSPNet, DeepLabV3, and MA-Net). Results: After rigorous hyperparameter optimization, all six deep learning models achieved mean Dice Similarity Coefficients (DSC) exceeding 0.823. Notably, FPN and PSPNet exhibited the fastest convergence rates. MA-Net stood out with the highest mean DSC of 0.875, demonstrating superior performance in arteriole segmentation. DeepLabV3 performed well in segmenting venous and capillary structures, while FPN exhibited proficiency in identifying immune cells and nerve trunks. An ensemble of these three models attained an average DSC of 0.889, surpassing their individual performances. Conclusion: This study showcases the potential of ML-driven segmentation in the analysis of histological images of tissue-engineered vascular grafts. Through the creation of a unique dataset and the optimization of deep neural network hyperparameters, we developed and validated an ensemble model, establishing an effective tool for detecting key histological features essential for understanding vascular tissue regeneration. These advances herald a significant improvement in ML-assisted workflows for tissue engineering research and development.

10.
Artif Organs ; 48(8): 821-830, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38975726

ABSTRACT

Pediatric heart transplantation is hampered by a chronic shortage of donor organs. This problem is further confounded by graft rejection. Identification of earlier indicators of pediatric graft rejection and development of subsequent strategies to counteract these effects will increase the longevity of transplanted pediatric hearts. Heart transplant reject is due to a complex series of events, resulting in CAV, which is thought to be mediated through a host immune response. However, the earlier events leading to CAV are not very well known. We hypothesize that early events related to ischemia reperfusion injury during pediatric heart transplantation are responsible for CAV and subsequent graft rejection. Identification of the molecular markers of ischemia reperfusion injury and development of subsequent therapies to block these pathways can potentially lead to a therapeutic strategy to reduce CAV and increase the longevity of the transplanted heart. To accomplish this goal, we have developed a perfusable vascular graft model populated with endothelial cells and demonstrated the feasibility of this model to understand the early events of ischemia reperfusion injury.


Subject(s)
Heart Defects, Congenital , Heart Transplantation , Heart Transplantation/methods , Heart Transplantation/adverse effects , Humans , Heart Defects, Congenital/surgery , Myocardial Reperfusion Injury/etiology , Endothelial Cells , Graft Rejection , Animals
11.
Front Bioeng Biotechnol ; 12: 1410863, 2024.
Article in English | MEDLINE | ID: mdl-38903186

ABSTRACT

Tissue-engineered vascular grafts (TEVGs) poised for regenerative applications are central to effective vascular repair, with their efficacy being significantly influenced by scaffold architecture and the strategic distribution of bioactive molecules either embedded within the scaffold or elicited from responsive tissues. Despite substantial advancements over recent decades, a thorough understanding of the critical cellular dynamics for clinical success remains to be fully elucidated. Graft failure, often ascribed to thrombogenesis, intimal hyperplasia, or calcification, is predominantly linked to improperly modulated inflammatory reactions. The orchestrated behavior of repopulating cells is crucial for both initial endothelialization and the subsequent differentiation of vascular wall stem cells into functional phenotypes. This necessitates the TEVG to provide an optimal milieu wherein immune cells can promote early angiogenesis and cell recruitment, all while averting persistent inflammation. In this study, we present an innovative TEVG designed to enhance cellular responses by integrating a physicochemical gradient through a multilayered structure utilizing synthetic (poly (ester urethane urea), PEUU) and natural polymers (Gelatin B), thereby modulating inflammatory reactions. The luminal surface is functionalized with a four-arm polyethylene glycol (P4A) to mitigate thrombogenesis, while the incorporation of adhesive peptides (RGD/SV) fosters the adhesion and maturation of functional endothelial cells. The resultant multilayered TEVG, with a diameter of 3.0 cm and a length of 11 cm, exhibits differential porosity along its layers and mechanical properties commensurate with those of native porcine carotid arteries. Analyses indicate high biocompatibility and low thrombogenicity while enabling luminal endothelialization and functional phenotypic behavior, thus limiting inflammation in in-vitro models. The vascular wall demonstrated low immunogenicity with an initial acute inflammatory phase, transitioning towards a pro-regenerative M2 macrophage-predominant phase. These findings underscore the potential of the designed TEVG in inducing favorable immunomodulatory and pro-regenerative environments, thus holding promise for future clinical applications in vascular tissue engineering.

12.
Adv Healthc Mater ; : e2400335, 2024 Jun 27.
Article in English | MEDLINE | ID: mdl-38935920

ABSTRACT

Cardiovascular diseases (CVDs) are the leading cause of mortality worldwide and represent a pressing clinical need. Vascular occlusions are the predominant cause of CVD and necessitate surgical interventions such as bypass graft surgery to replace the damaged or obstructed blood vessel with a synthetic conduit. Synthetic small-diameter vascular grafts (sSDVGs) are desired to bypass blood vessels with an inner diameter <6 mm yet have limited use due to unacceptable patency rates. The incorporation of biophysical cues such as topography onto the sSDVG biointerface can be used to mimic the cellular microenvironment and improve outcomes. In this review, the utility of surface topography in sSDVG design is discussed. First, the primary challenges that sSDVGs face and the rationale for utilizing biomimetic topography are introduced. The current literature surrounding the effects of topographical cues on vascular cell behavior in vitro is reviewed, providing insight into which features are optimal for application in sSDVGs. The results of studies that have utilized topographically-enhanced sSDVGs in vivo are evaluated. Current challenges and barriers to clinical translation are discussed. Based on the wealth of evidence detailed here, substrate topography offers enormous potential to improve the outcome of sSDVGs and provide therapeutic solutions for CVDs.

13.
Adv Healthc Mater ; 13(23): e2400855, 2024 Sep.
Article in English | MEDLINE | ID: mdl-38780418

ABSTRACT

Synthetic vascular grafts are used to bypass significant arterial blockage when native blood vessels are unsuitable, yet their propensity to fail due to poor blood compatibility and progressive graft stenosis remains an intractable challenge. Perlecan is the major heparan sulfate (HS) proteoglycan in the blood vessel wall with an inherent ability to regulate vascular cell activities associated with these major graft failure modes. Here the ability of the engineered form of perlecan domain V (rDV) to bind angiogenic growth factors is tuned and endothelial cell proliferation via the composition of its glycosaminoglycan (GAG) chain is supported. It is shown that the HS on rDV supports angiogenic growth factor signaling, including fibroblast growth factor (FGF) 2 and vascular endothelial growth factor (VEGF)165, while both HS and chondroitin sulfate on rDV are involved in VEGF189 signaling. It is also shown that physisorption of rDV on emerging electrospun silk fibroin vascular grafts promotes endothelialization and patency in a murine arterial interposition model, compared to the silk grafts alone. Together, this study demonstrates the potential of rDV as a tunable, angiogenic biomaterial coating that both potentiates growth factors and regulates endothelial cells.


Subject(s)
Blood Vessel Prosthesis , Heparan Sulfate Proteoglycans , Heparan Sulfate Proteoglycans/chemistry , Heparan Sulfate Proteoglycans/metabolism , Animals , Humans , Mice , Vascular Endothelial Growth Factor A/metabolism , Vascular Endothelial Growth Factor A/pharmacology , Vascular Endothelial Growth Factor A/chemistry , Human Umbilical Vein Endothelial Cells/metabolism , Neovascularization, Physiologic/drug effects , Silk/chemistry , Cell Proliferation/drug effects , Recombinant Proteins/pharmacology , Recombinant Proteins/chemistry , Endothelial Cells/metabolism , Endothelial Cells/drug effects , Endothelial Cells/cytology , Protein Domains , Fibroblast Growth Factor 2/pharmacology , Fibroblast Growth Factor 2/chemistry , Fibroblast Growth Factor 2/metabolism
14.
JTCVS Open ; 18: 209-220, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38690440

ABSTRACT

Objectives: The complexity of aortic arch reconstruction due to diverse 3-dimensional geometrical abnormalities is a major challenge. This study introduces 3-dimensional printed tissue-engineered vascular grafts, which can fit patient-specific dimensions, optimize hemodynamics, exhibit antithrombotic and anti-infective properties, and accommodate growth. Methods: We procured cardiac magnetic resonance imaging with 4-dimensional flow for native porcine anatomy (n = 10), from which we designed tissue-engineered vascular grafts for the distal aortic arch, 4 weeks before surgery. An optimal shape of the curved vascular graft was designed using computer-aided design informed by computational fluid dynamics analysis. Grafts were manufactured and implanted into the distal aortic arch of porcine models, and postoperative cardiac magnetic resonance imaging data were collected. Pre- and postimplant hemodynamic data and histology were analyzed. Results: Postoperative magnetic resonance imaging of all pigs with 1:1 ratio of polycaprolactone and poly-L-lactide-co-ε-caprolactone demonstrated no specific dilatation or stenosis of the graft, revealing a positive growth trend in the graft area from the day after surgery to 3 months later, with maintaining a similar shape. The peak wall shear stress of the polycaprolactone/poly-L-lactide-co-ε-caprolactone graft portion did not change significantly between the day after surgery and 3 months later. Immunohistochemistry showed endothelization and smooth muscle layer formation without calcification of the polycaprolactone/poly-L-lactide-co-ε-caprolactone graft. Conclusions: Our patient-specific polycaprolactone/poly-L-lactide-co-ε-caprolactone tissue-engineered vascular grafts demonstrated optimal anatomical fit maintaining ideal hemodynamics and neotissue formation in a porcine model. This study provides a proof of concept of patient-specific tissue-engineered vascular grafts for aortic arch reconstruction.

15.
J Clin Med ; 13(10)2024 May 16.
Article in English | MEDLINE | ID: mdl-38792466

ABSTRACT

Background: Treatment of established portal vein narrowing after living donor hepatectomy is challenging. We aimed to present a new approach termed the "elbow patch reconstruction technique" to correct the narrowed remnant portal vein just or late after right lobe living donor hepatectomy. Methods: Demographic and clinical data of 12 living liver donors with narrowed remnant portal veins and treated with the "elbow patch reconstruction technique" were prospectively collected and retrospectively evaluated. Anatomic variation of the portal vein was defined in accordance with the Nakamura classification; six of the living liver donors had type A, three had type B, and the remaining three had type C. In eight of the living liver donors with a narrowed remnant portal vein, diagnosis was detected by intraoperative Doppler ultrasonography and visual inspection by experienced transplant surgeons in the living donor hepatectomy procedure. In the remaining four living liver donors, diagnosis was performed postoperatively when elevation of liver enzymes was noticed during the routine liver function test and Doppler US. The diagnosis was confirmed by multidetector computed tomography. Results: Data from nine males and three females aged 18 to 54 years were analyzed. All of the living liver donors were followed up for a median of 1710 days (min-max: 1178-4447 days; IQR: 1516 days), and none of the living liver donors had any structural or functional complications in the portal vein. Conclusions: Narrowing remnant portal veins are rare, but they are a life-threatening complication in living liver donors, and this condition requires urgent management. Image guided interventions and narrowed segment resection with end-to-end anastomosis using a vascular graft carried a potential risk for thrombosis and restenosis. To avoid these complications, we shared a technique named "elbow patch reconstruction technique". This technique can be very effective in relieving the narrowing of the remnant portal vein after right lobe living donor hepatectomy.

16.
ACS Biomater Sci Eng ; 10(6): 3631-3654, 2024 06 10.
Article in English | MEDLINE | ID: mdl-38815169

ABSTRACT

The transplantation of vascular grafts has emerged as a prevailing approach to address vascular disorders. However, the development of small-diameter vascular grafts is still in progress, as they serve in a more complicated mechanical environment than their counterparts with larger diameters. The biocompatibility and functional characteristics of small-diameter vascular grafts have been well developed; however, mismatch in mechanical properties between the vascular grafts and native arteries has not been accomplished, which might facilitate the long-term patency of small-diameter vascular grafts. From a point of view in mechanics, mimicking the nonlinear elastic mechanical behavior exhibited by natural blood vessels might be the state-of-the-art in designing vascular grafts. This review centers on elucidating the nonlinear elastic behavior of natural blood vessels and vascular grafts. The biological functionality and limitations associated with as-reported vascular grafts are meticulously reviewed and the future trajectory for fabricating biomimetic small-diameter grafts is discussed. This review might provide a different insight from the traditional design and fabrication of artificial vascular grafts.


Subject(s)
Blood Vessel Prosthesis , Blood Vessels , Elasticity , Humans , Blood Vessels/physiology , Animals , Biocompatible Materials/chemistry
17.
Adv Healthc Mater ; 13(19): e2400426, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38607966

ABSTRACT

Melt Electrowriting (MEW) is a continuously growing manufacturing platform. Its advantage is the consistent production of micro- to nanometer fibers, that stack intricately, forming complex geometrical shapes. MEW allows tuning of the mechanical properties of constructs via the geometry of deposited fibers. Due to this, MEW can create complex mechanics only seen in multi-material compounds and serve as guiding structures for cellular alignment. The advantage of MEW is also shown in combination with other biotechnological manufacturing methods to create multilayered constructs that increase mechanical approximation to native tissues, biocompatibility, and cellular response. These features make MEW constructs a perfect candidate for small-diameter vascular graft structures. Recently, studies have presented fascinating results in this regard, but is this truly the direction that tubular MEW will follow or are there also other options on the horizon? This perspective will explore the origins and developments of tubular MEW and present its growing importance in the field of artificial small-diameter vascular grafts with mechanical modulation and improved biomimicry and the impact of it in convergence with other manufacturing methods and how future technologies like AI may influence its progress.


Subject(s)
Blood Vessel Prosthesis , Tissue Engineering , Humans , Tissue Engineering/methods , Blood Vessels/physiology , Biocompatible Materials/chemistry , Animals , Tissue Scaffolds/chemistry
18.
J Mech Behav Biomed Mater ; 154: 106531, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38588633

ABSTRACT

Despite polyester vascular grafts being routinely used in life-saving aortic aneurysm surgeries, they are less compliant than the healthy, native human aorta. This mismatch in mechanical behaviour has been associated with disruption of haemodynamics contributing to several long-term cardiovascular complications. Moreover, current fabrication approaches mean that opportunities to personalise grafts to the individual anatomical features are limited. Various modifications to graft design have been investigated to overcome such limitations; yet optimal graft functionality remains to be achieved. This study reports on the development and characterisation of an alternative vascular graft material. An alginate:PEGDA (AL:PE) interpenetrating polymer network (IPN) hydrogel has been produced with uniaxial tensile tests revealing similar strength and stiffness (0.39 ± 0.05 MPa and 1.61 ± 0.19 MPa, respectively) to the human aorta. Moreover, AL:PE tubular conduits of similar geometrical dimensions to segments of the aorta were produced, either via conventional moulding methods or stereolithography (SLA) 3D-printing. While both fabrication methods successfully demonstrated AL:PE hydrogel production, SLA 3D-printing was more easily adaptable to the fabrication of complex structures without the need of specific moulds or further post-processing. Additionally, most 3D-printed AL:PE hydrogel tubular conduits sustained, without failure, compression up to 50% their outer diameter and returned to their original shape upon load removal, thereby exhibiting promising behaviour that could withstand pulsatile pressure in vivo. Overall, these results suggest that this AL:PE IPN hydrogel formulation in combination with 3D-printing, has great potential for accelerating progress towards personalised and mechanically-matched aortic grafts.


Subject(s)
Aortic Aneurysm , Printing, Three-Dimensional , Humans , Blood Vessel Prosthesis , Aorta , Hydrogels
19.
Regen Biomater ; 11: rbae029, 2024.
Article in English | MEDLINE | ID: mdl-38638701

ABSTRACT

Arteriovenous grafts (AVGs) have emerged as the preferred option for constructing hemodialysis access in numerous patients. Clinical trials have demonstrated that decellularized vascular graft exhibits superior patency and excellent biocompatibility compared to polymer materials; however, it still faces challenges such as intimal hyperplasia and luminal dilation. The absence of suitable animal models hinders our ability to describe and explain the pathological phenomena above and in vivo adaptation process of decellularized vascular graft at the molecular level. In this study, we first collected clinical samples from patients who underwent the construction of dialysis access using allogeneic decellularized vascular graft, and evaluated their histological features and immune cell infiltration status 5 years post-transplantation. Prior to the surgery, we assessed the patency and intimal hyperplasia of the decellularized vascular graft using non-invasive ultrasound. Subsequently, in order to investigate the in vivo adaptation of decellularized vascular grafts in an animal model, we attempted to construct an AVG model using decellularized vascular grafts in a small animal model. We employed a physical-chemical-biological approach to decellularize the rat carotid artery, and histological evaluation demonstrated the successful removal of cellular and antigenic components while preserving extracellular matrix constituents such as elastic fibers and collagen fibers. Based on these results, we designed and constructed the first allogeneic decellularized rat carotid artery AVG model, which exhibited excellent patency and closely resembled clinical characteristics. Using this animal model, we provided a preliminary description of the histological features and partial immune cell infiltration in decellularized vascular grafts at various time points, including Day 7, Day 21, Day 42, and up to one-year post-implantation. These findings establish a foundation for further investigation into the in vivo adaptation process of decellularized vascular grafts in small animal model.

20.
Biomed Mater ; 19(3)2024 Mar 22.
Article in English | MEDLINE | ID: mdl-38430567

ABSTRACT

In our previous study, the pristine bilayer small-diameterin situtissue engineered vascular grafts (pTEVGs) were electrospun from a heparinized polycaprolactone (PCL45k) as an inner layer and a non-heparinized PCL80k as an outer layer in the thickness of about 131 µm and 202 µm, respectively. However, the hydrophilic enhancement of inner layer stemmed from the heparinization accelerated the degradation of grafts leading to the early formation of arterial aneurysms in a period of 3 months, severely hindering the perennial observation of the neo-tissue regeneration, host cell infiltration and graft remodeling in those implanted pTEVGs. Herein to address this drawback, the thickness of the outer layers was increased with PCL80k to around 268 µm, while the inner layer remained unchangeable. The thickened TEVGs named as tTEVGs were evaluated in six rabbits via a carotid artery interpositional model for a period of 9 months. All the animals kept alive and the grafts remained patent until explantation except for one whose one side of arterial blood vessels was occluded after an aneurysm occurred at 6 months. Although a significant degradation was observed in the implanted grafts at 9 month, the occurrence of aneurysms was obviously delayed compared to pTEVGs. The tissue stainings indicated that the endothelial cell remodeling was substantially completed by 3 months, while the regeneration of elastin and collagen remained smaller and unevenly distributed in comparison to autologous vessels. Additionally, the proliferation of macrophages and smooth muscle cells reached the maximum by 3 months. These tTEVGs possessing a heparinized inner layer and a thickened outer layer exhibited good patency and significantly delayed onset time of aneurysms.


Subject(s)
Aneurysm , Polyesters , Tissue Engineering , Animals , Rabbits , Blood Vessel Prosthesis , Carotid Arteries