Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 17 de 17
Filter
1.
BJOG ; 131(9): 1270-1278, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38497098

ABSTRACT

OBJECTIVE: To assess the clinical utility of point-of-care (POC) capillary blood glucose (CBG) testing in the assessment of gestational diabetes mellitus (GDM) during oral glucose tolerance test (OGTT). DESIGN: Prospective cohort study. SETTING: Antenatal clinics at King's College Hospital. POPULATION: Women screened for GDM between March and June 2020. METHODS: The CBG was measured using the POC StatStrip® test and the venous plasma glucose (VPG) was measured by Roche analyser (Cobas 8000 c702). GDM was diagnosed based on the 2015 National Institute for Health and Clinical Excellence (NICE) Clinical Guideline criteria. The two methods were compared statistically using Analyse-It 5.40.2. MAIN OUTCOME MEASURES: Diagnostic sensitivity, specificity, positive and negative predictive values (PPV and NPV) for the POC StatStrip® test, compared with VPG measured by reference laboratory method. RESULTS: A total of 230 women were included. The number and percentage of women with glucose concentrations above the GDM threshold using the POC StatStrip® test versus laboratory VPG measurement was 15 (6.5%) versus eight (3.4%) at fasting and 105 (45.6%) versus 72 (31.1%) at 2 h, respectively. The sensitivity and specificity values (and 95% CIs) for the POC StatStrip® test were 88% (52%-99%) and 97% (93%-98%) at fasting and 97% (91%-99%) and 79% (71%-84%) at 2 h, respectively. However, the specificity and the NPV for the POC StatStrip® test for concentrations of ≤5.0 mmol/L at fasting or <7.5 mmol/L at 2 h were 100%, and the sensitivity and the PPV for concentrations of >9.5 mmol/L at 2 h were 100%. CONCLUSIONS: In our cohort the POC measurement of CBG cannot entirely replace the laboratory method for the OGTT; however, it can be used to rule out/rule in GDM for glucose concentrations of ≤5.0 mmol/L at fasting or <7.5/>9.5 mmol/L at 2 h.


Subject(s)
Blood Glucose , Diabetes, Gestational , Glucose Tolerance Test , Point-of-Care Testing , Sensitivity and Specificity , Humans , Female , Diabetes, Gestational/diagnosis , Diabetes, Gestational/blood , Pregnancy , Prospective Studies , Blood Glucose/analysis , Adult , Predictive Value of Tests , Point-of-Care Systems/standards
2.
J Proteome Res ; 22(4): 1347-1358, 2023 04 07.
Article in English | MEDLINE | ID: mdl-36882937

ABSTRACT

Blood contains a great deal of health-related information and can be used to monitor human health status. Clinically, venous or fingertip blood is usually used for blood tests. However, the clinical application settings of the two sources of blood are unclear. In this study, the proteomes of pairwise venous plasma (VP) and fingertip plasma (FP) were analyzed, and the levels of 3797 proteins were compared between VP and FP. The Spearman's correlation coefficient for the relationship between protein levels of VP and FP ranges from 0.64 to 0.78 (p < 0.0001). The common pathways of VP and FP are related to cell-cell adhesion, protein stabilization, innate immune response, and complement activation, the classical pathway. The VP-overrepresented pathway is related to actin filament organization, while the FP-overrepresented pathway is related to the hydrogen peroxide catabolic process. ADAMTSL4, ADIPOQ, HIBADH, and XPO5 both in VP and FP are potential gender-related proteins. Notably, the VP proteome has a higher interpretation on age than the FP proteome, and CD14 is a potential age-related protein in VP but not in FP. Our study mapped the different proteomes between VP and FP, which can provide value for the standardization of clinical blood tests.


Subject(s)
Proteome , Proteomics , Humans , Proteome/genetics , Proteome/metabolism , Karyopherins
3.
Diabetol Int ; 13(3): 561-565, 2022 Jul.
Article in English | MEDLINE | ID: mdl-35693996

ABSTRACT

Purpose: To assess the accuracy of capillary blood glucose (CBG) compared to conventional venous plasma glucose (VPG) testing for 50-g glucose challenge test (GCT) in gestational diabetes (GDM) screening. Methods: A total of 300 women were enrolled and 50-g GCT for GDM screening was offered. At 1 h after glucose loading, CBG was evaluated by CONTOUR® PLUS glucose meter by well-trained nurses immediately after venipuncture for VPG. Results of CBG were compared with those from VPG to evaluate its accuracy. Women with venous plasma glucose > 140 mg/dL were offered 100-g OGTT for GDM diagnosis. Results: The mean age was 30.2 years and the mean gestational age at testing was 21.8 weeks. GDM was diagnosed in 34 women (11.3%). The mean VPG was 142.1 ± 32.9 mg/dL and the mean CBG was 129.3 ± 33.5 mg/dL. Mean difference was -12.3 ± 12.5 mg/dL, corresponding to -8.8 ± 11.4%. CBG significantly correlated with VPG with correlation coefficient of 0.929, p < 0.001. In the detection of abnormal 50-g GCT results (VPG ≥ 140 mg/dL), at 126 mg/dL cutoff, CBG had sensitivity of 92.5%, specificity of 81.8%, and positive and negative predictive values of 82.8%and 92%. None of the GDM would have been missed if CBG was used. Conclusion: CBG by a certified glucose meter could be considered as an alternative to conventional VPG testing for 50-g GCT for GDM screening using 126 mg/dL cutoff value.

4.
Lab Med ; 53(2): 199-205, 2022 Mar 07.
Article in English | MEDLINE | ID: mdl-34661656

ABSTRACT

OBJECTIVE: To determine the consistency of bilirubin values between the direct spectrophotometric (DS) and colorimetric diazo (diazo) methods in neonatal venous plasma specimens. METHODS: We measured the total bilirubin via the DS and diazo methods in 255 neonatal venous plasma specimens and compared the overall and subgroup results. RESULTS: Slight underestimation of total bilirubin values in most specimens using the DS method was observed, with higher mean biases found in higher concentrations. Significantly high positive correlations were found in all groups in which most of the different values were within the limits of agreement. DS cutoff of > 12 mg/dL showed 100% for all predictive indices in comparison with the diazo cutoff > 15 mg/dL. CONCLUSIONS: Measurement of total bilirubin in neonatal venous plasma using the DS method had favorable agreement and high correlation with the diazo method. Therefore, the direct spectrophotometric method can be used as a reliable screening method.


Subject(s)
Bilirubin , Research Design , Humans , Infant, Newborn
5.
Talanta ; 192: 182-188, 2019 Jan 15.
Article in English | MEDLINE | ID: mdl-30348376

ABSTRACT

Blood tests, which are used to evaluate health status, are relatively non-invasive and provide a great deal of health-related information. Blood is usually collected using a standard venous blood sampling protocol, but it is possible to collect blood from a subject's fingertip, and previous studies have investigated whether fingertip-derived blood can be used for various blood tests. In this study, the proteomes and metabolomes of venous and fingertip plasma were analyzed using non-targeted proteomics and metabolomics, respectively. In proteomics, the levels of 523 proteins were compared between venous and fingertip plasma. The correlation coefficient (r) for the relationship between protein levels of venous and fingertip plasma was 0.9999. Some proteins had high fingertip to venous plasma level ratios (finger:venous ratios), whereas others had low finger:venous ratios, and the mean±standard deviation (SD) finger:venous ratio was 0.994 ±â€¯0.304. In metabolomics, 40, 33, and 216 cationic metabolites, anionic metabolites, and lipids, respectively, were detected in venous plasma, and the equivalent figures for fingertip plasma were 40, 35, and 216, respectively. Regarding the correlations between metabolite levels in venous and fingertip plasma, the correlation coefficients (r) for cationic metabolites, anionic metabolites, and lipids were 0.9952, 0.9699, and 0.9980, respectively. The mean±SD finger:venous ratio was 1.19 ±â€¯0.584 for cationic metabolites, 1.23 ±â€¯0.548 for anionic metabolites, and 1.00 ±â€¯0.245 for lipids. Our study suggests that it might be possible to use fingertip plasma to measure plasma protein and metabolite levels, and will contribute to development of a fingertip blood sampling procedure for measuring blood biomarker levels.


Subject(s)
Blood Chemical Analysis , Blood Proteins/analysis , Blood Proteins/metabolism , Blood Specimen Collection , Metabolomics , Proteomics , Fingers , Humans
6.
Oncotarget ; 8(17): 28471-28480, 2017 Apr 25.
Article in English | MEDLINE | ID: mdl-28212530

ABSTRACT

Circulating microRNAs presented in venous plasma have been demonstrated as powerful biomarkers for the complex diseases like cancer. Nevertheless, those presented in arterial plasma remained largely unexplored. Here, using microarray technique, we compared microRNA expression profiles of the matched arterial and venous plasma samples from the same male rats. Though the microRNA profiles were largely similar, we identified 24 differentially expressed microRNAs, including 10 arterial highly expressed microRNAs and 14 venous highly expressed microRNAs. The differentially expressed microRNAs were validated by qRT-PCR. Computational analysis of these microRNAs and their targets indicated that arterial highly expressed microRNAs were overrepresented for functional terms like hematopoiesis and diseases like Crohn's Disease and leukemia; while venous highly expressed microRNAs were enriched for cell differentiation function, and diseases like distal myopathies and heart failure. Our analysis also suggested significant correlations between plasma microRNA expression and tissue microRNA expression. Four arterial highly expressed microRNAs also showed enriched expression in specific tissues and would be novel biomarker candidates.


Subject(s)
Arteries , Circulating MicroRNA , MicroRNAs/blood , MicroRNAs/genetics , Transcriptome , Veins , Animals , Biomarkers , Computational Biology/methods , Gene Expression Profiling , Gene Expression Regulation , Liquid Biopsy , Male , Organ Specificity , Rats
7.
Acta Diabetol ; 53(1): 91-7, 2016 Feb.
Article in English | MEDLINE | ID: mdl-25916215

ABSTRACT

AIMS: The aim of the study was to evaluate usefulness of capillary blood glucose (CBG) for diagnosis of gestational diabetes mellitus (GDM) in resource-constrained settings where venous plasma glucose (VPG) estimations may be impossible. METHODS: Consecutive pregnant women (n = 1031) attending antenatal clinics in southern India underwent 75-g oral glucose tolerance test (OGTT). Fasting, 1- and 2-h VPG (AU2700 Beckman, Fullerton, CA) and CBG (One Touch Ultra-II, LifeScan) were simultaneously measured. Sensitivity and specificity were estimated for different CBG cut points using the International Association of Diabetes in Pregnancy Study Groups (IADPSG) criteria for the diagnosis of GDM as gold standard. Bland-Altman plots were drawn to look at the agreement between CBG and VPG. Correlation and regression equation analysis were also derived for CBG values. RESULTS: Pearson's correlation between VPG and CBG for fasting was r = 0.433 [intraclass correlation coefficient (ICC) = 0.596, p < 0.001], for 1H, it was r = 0.653 (ICC = 0.776, p < 0.001), and for 2H, r = 0.784 (ICC = 0.834, p < 0.001). Comparing a single CBG 2-h cut point of 140 mg/dl (7.8 mmol/l) with the IADPSG criteria, the sensitivity and specificity were 62.3 and 80.7 %, respectively. If CBG cut points of 120 mg/dl (6.6 mmol/l) or 110 mg/dl (6.1 mmol/l) were used, the sensitivity improves to 78.3 and 92.5 %, respectively. CONCLUSIONS: In settings where VPG estimations are not possible, CBG can be used as an initial screening test for GDM, using lower 2H CBG cut points to maximize the sensitivity. Those who screen positive can be referred to higher centers for definitive testing, using VPG.


Subject(s)
Blood Glucose/analysis , Capillaries/chemistry , Diabetes, Gestational/diagnosis , Poverty , Prenatal Diagnosis/methods , Adult , Diabetes, Gestational/blood , Diabetes, Gestational/economics , Diabetes, Gestational/epidemiology , Fasting/blood , Female , Glucose Tolerance Test/economics , Glucose Tolerance Test/methods , Health Resources/economics , Humans , India/epidemiology , Poverty/statistics & numerical data , Pregnancy , Prenatal Diagnosis/economics , Sensitivity and Specificity , Young Adult
8.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-463340

ABSTRACT

Objective To study the difference of electrolyte levels between different peripheral blood samples .Methods A total of 100 patients were enrolled and collected for artery whole blood samples and vein plasma samples .Potassium ,sodium and chloride levels of artery whole blood ,artery plasma and vein plasma were tested by using ROCHE AVL 9180 analyzer .Results Sodium and chloride levels in artery whole blood and artery plasma were statistically different (P0 .05) .Sodium and chloride levels in artery whole blood and vein plasma were statistically different (P0 .05) .Conclusion Sodium and chloride concentration of ar‐terial whole blood and arterial plasma ,vein plasma could be different ,but the concentration of potassium could be reference for each other .

9.
Article in Korean | WPRIM (Western Pacific) | ID: wpr-124411

ABSTRACT

OBJECTIVE: To evaluate their roles in the pathophysiology of preterm premature rupture of membranes (PPROM), we checked interleukin (IL)-6, lipid peroxide, oxygen-radical absorbance capacity (ORAC) and antioxidant vitamin in the venous plasma and amniotic fluid of women with PPROM. METHODS: Venous plasma and amniotic fluid was taken from 20 normal pregnant women and 20 PPROM pregnancy women. IL-6 levels was determined by enzyme-linked immunosorbent assay. Lipid peroxide levels were measured by thiobarbituric acid reaction. The ORAC levels and the antioxidant levels were measured by Cao's method and by high performance liquid chromatography. RESULTS: The IL-6 levels in the venous plasma and amniotic fluid of PPROM pregnancy women were significantly higher than normal pregancy (P<0.01, P<0.01). The lipid peroxide levels in the venous plasma and amniotic fluid of PPROM pregnancy women were significantly higher than normal pregancy (P<0.01, P<0.01). The ORAC values in the venous plasma and amniotic fluid of PPROM pregnancy women were significantly higher than normal pregancy (P<0.01, P<0.01). The ORAC values/lipid peroxide levels in the venous plasma and amniotic fluid of PPROM pregnancy women were significantly higher than normal pregancy (P<0.01, P<0.01). The ascorbic acid levels in the venous plasma and amniotic fluid of PPROM pregnancy women were significantly higher than normal pregancy (P<0.05, P<0.01). CONCLUSION: This result suggest that the increased inflammatory bioactivity, increased lipid peroxidation and decreased antioxidant activity may be involved in the pathophysiology of PPROM. Low levels of ascorbic acid appears to be an important determinant of PPROM.


Subject(s)
Female , Humans , Pregnancy , Amniotic Fluid , Ascorbic Acid , Chromatography, Liquid , Enzyme-Linked Immunosorbent Assay , Interleukin-6 , Interleukins , Lipid Peroxidation , Membranes , Plasma , Pregnant Women , Rupture , Thiobarbiturates , Vitamins
10.
Article in Korean | WPRIM (Western Pacific) | ID: wpr-94827

ABSTRACT

OBJECTIVE: This controlled trial investigated the effect of supplementation with vitamins C and E on the lipid peroxide, antioxidant ability, and antioxidant vitamin levels in full term maternal and umbilical venous plasma. METHODS: Forty pregnant women were randomized in this study. They were nulliparous or multiparous women with history of preeclampsia or preterm premature rupture of membranes (PPROM). Twenty women were given vitamin C (1,000 mg/day) and vitamin E (400 IU/day) from 15~20 gestational weeks to delivery. The others were not given, as a control group. Maternal venous blood was obtained before vitamin supplementation and just before delivery. Umbilical venous blood was obtained after delivery. Lipid peroxide level and oxygen-radical absorbance capacity (ORAC) were measured by thiobarbituric acid reaction and Cao's method, respectively. Ascorbic acid, uric acid, beta-carotene, retinol, alpha-tocopherol, and gamma-tocopherol were measured by high performance liquid chromatography. Results: Supplementation with vitamins C and E was associated with decrease in lipid peroxide levels and increase in ORAC values and alpha-tocopherol levels in maternal venous plasma. And it was also associated with decrease in lipid peroxide levels and increase in ORAC values and alpha-tocopherol levels in umbilical venous plasma. CONCLUSION: Supplementation with vitamins C and E may be beneficial in the prevention of oxidant-antioxidant imbalance origin diseases such as preeclampsia, PPROM. And it also may affect antioxidant ability of the fetus.


Subject(s)
Female , Humans , alpha-Tocopherol , Ascorbic Acid , beta Carotene , Fetus , gamma-Tocopherol , Membranes , Plasma , Pre-Eclampsia , Pregnant Women , Rupture , Thiobarbiturates , Uric Acid , Vitamin A , Vitamin E , Vitamins
11.
Article in Korean | WPRIM (Western Pacific) | ID: wpr-92709

ABSTRACT

PURPOSE:To investigate the change in the antioxidant vitamin levels in maternal uterine venous plasma (MUVP), amniotic fluid (AF), and chorioamnion after vitamin C and E supplementation during pregnancy. METHODS:Thirty pregnant women who were scheduled for elective cesarean section between 37 and 39 gestational weeks were randomized in this study. Fifteen women were given a daily oral dose of vitamin C 1,000 mg and vitamin E 400 IU from 33~34 gestational weeks to delivery. The other fifteen women were not given, as a control group. Maternal uterine venous blood, AF, and chorioamnion were obtained after cesarean section. Lipid peroxides and oxygen-radical absorbance capacity value were measured by thiobarbituric acid reaction and Cao's method respectively. Ascorbic acid, uric acid, beta-carotene, retinol, alpha-tocopherol, and gamma-tocopherol were measured by high performance liquid chromatography. The tissue sections of chorioamnion were stained with hematoxylin-eosin and Masson-trichrome stain, and immunohistochemical stain for collagen type IV was also performed. RESULTS:The lipid peroxide levels in MUVP of the study group were significantly lower than those of the control group but in contrast, ORAC (Oxygen-radical absorbance capacity) values were lower in the control group. The alpha-tocopherol levels in MUVP, AF, and chorioamnion study group were significantly higher than those of the control group. Amniotic membrane and subepithelial stromal tissue in the study group were thicker than those in the control group. And subchorionic type IV collagen of placenta tissue in the study group was more stained than that of the control group. CONCLUSION:Maternal vitamin C and E supplementation may be beneficial in the prevention of diseases caused by oxidative stress such as preeclampsia and PROM and in increasing fibrin and type IV collagen in chorioamnion.


Subject(s)
Female , Humans , Pregnancy , alpha-Tocopherol , Amnion , Amniotic Fluid , Ascorbic Acid , beta Carotene , Cesarean Section , Chromatography, Liquid , Collagen Type IV , Fibrin , gamma-Tocopherol , Lipid Peroxides , Oxidative Stress , Placenta , Plasma , Pre-Eclampsia , Pregnant Women , Thiobarbiturates , Uric Acid , Vitamin A , Vitamin E , Vitamins
12.
Article in Korean | WPRIM (Western Pacific) | ID: wpr-59234

ABSTRACT

OBJECTIVE:To investigate interleukin-6 (IL-6), C-reactive protein (CRP), and lipid peroxide levels in the umbilical venous plasma of preterm birth with or without histologic chorioamnionitis and to evaluate their roles in the pathophysiology in preterm labor and perinatal outcome. METHODS:This cohort study included 66 cases of preterm delivery with preterm labor and intact membranes (PTL) (n=39) and preterm premature rupture of membranes (PPROM) (n=27). The umbilical venous blood samples were collected at the time of delivery. IL-6, CRP, and lipid peroxide levels were measured by ELISA Kit, latex agglutination assay, and thiobarbituric acid reaction. Histologic chorioamnionitis was diagnosed by the presence of neutrophil infiltration into the subamnionic space. RESULTS:The prevalence of histologic chorioamnionitis was significantly higher in PPROM (59.3 %, 16/27) than in PTL (20.5%, 8/39). IL-6, CRP, and lipid peroxide levels in the umbilical venous plasma of histologic chorioamnionitis were significantly higher than those without histologic chorioamnionitis. IL-6, CRP, and lipid peroxide levels in the umbilical venous plasma of PTL with histologic chorioamnionitis were significantly higher than those of PTL without histologic chorioamnionitis. CRP levels in the umbilical venous plasma of PPROM with histologic chorioamnionitis were significantly higher than those of PPROM without histologic chorioamnionitis. Three suspected neonatal sepsis patients have increased IL-6 and lipid peroxide levels in the umbilical venous plasma compared with patients without neonatal sepsis. IL-6 levels in the umbilical venous plasma of histologic funisitis were significantly higher than those without funisitis. CONCLUSION:Preterm birth with chorioamnionitis is associated with an increased level of IL-6, CRP, and lipid peroxide in umbilical venous blood. Preterm birth with chorioamnionitis may have an effect on perinatal outcome.


Subject(s)
Female , Humans , Pregnancy , Agglutination , C-Reactive Protein , Chorioamnionitis , Cohort Studies , Enzyme-Linked Immunosorbent Assay , Interleukin-6 , Latex , Membranes , Neutrophil Infiltration , Obstetric Labor, Premature , Parturition , Plasma , Premature Birth , Prevalence , Rupture , Sepsis
13.
Article in Korean | WPRIM (Western Pacific) | ID: wpr-41233

ABSTRACT

OBJECTIVE: To compare interleukin-6 (IL-6), tumor necrosis factor-alpha(TNF-alpha), oxygen-radical absorbance capacity (ORAC), and antioxidant vitamin levels in the umbilical venous plasma of preterm labor with intact membranes (PTL) and preterm premature rupture of membrane (PPROM) with that of full term normal pregnancy (NP) and to evaluate their roles of pathophysiology in preterm labor and PPROM. METHODS: Umbilical venous blood samples were collected from women with PTL (n=30), PPROM (n=30) and NP (n=30). IL-6 and TNF-alpha were measured by enzyme-linked immunosorbent assay. Lipid peroxide levels were measured by thiobarbituric acid reaction. The ORAC was mesured by Cao's method. Antioxidant vitamin levels were measured by high performance liquid chromatography. RESULTS: IL-6 and TNF-alpha levels in the umbilical venous plasma of PPROM were significantly higher than that of PTL and NP (3.28+/-0.31 vs. 2.84+/-0.19 vs. 2.79+/-0.22 pg/ml, p<0.05), (2.30+/-0.27 vs. 1.64+/-0.23 vs. 1.40+/-0.25 pg/ml, p<0.01). Lipid peroxide levels in the umbilical venous plasma of PPROM were significantly higher than that of NP and PTL (2.78+/-0.27 vs. 2.54+/-0.32 vs. 2.24+/-0.24 nmol/mg protein, p<0.01). ORAC levels in the umbilical venous plasma of PTL and PPROM were significantly lower than that of NP (967425.4+/-98.99 vs. 965165.8+/-91.20 vs. 1011328.5+/-85.96 U/ml, p<0.05). Ascorbic acid levels in the umbilical venous plasma of PPROM were significantly lower than that of NP and PTL (125.6+/-2.33 vs. 158.3+/-3.08 vs. 221.7+/-2.82 nmol/ml, p<0.01). CONCLUSION: Increase in inflammatory cytokines (IL-6, TNF-alpha) and imbalance of increased lipid peroxidation and decreased antioxidant activity in umbilical venous blood may be involved in the pathophysiology of PPROM.


Subject(s)
Female , Humans , Pregnancy , Ascorbic Acid , Chromatography, Liquid , Cytokines , Enzyme-Linked Immunosorbent Assay , Interleukin-6 , Lipid Peroxidation , Membranes , Necrosis , Obstetric Labor, Premature , Plasma , Premature Birth , Rupture , Tumor Necrosis Factor-alpha , Vitamins
14.
Article in Korean | WPRIM (Western Pacific) | ID: wpr-116333

ABSTRACT

OBJECTIVE: Our purpose was to investigate Interleukin-6 (IL-6), tumor necrotic factor-alpha (TNF-alpha), lipid peroxide levels, oxygen-radical absorbance capacity (ORAC), and antioxidant levels in umbilical venous blood plasma and to evaluate the roles of them in the pathophysiology of preeclampsia. STUDY DESIGN: Samples of umbilical venous plasma were obtained from 20 normal and 20 preeclamptic women between 33 and 40 weeks gestation. IL-6 and TNF-alpha was assayed by an enzyme-linked immunoassay. Lipid peroxide levels were measured by thiobarbituric acid reaction. The ORAC values were measured by Cao's method. Ascorbic acid, retinol, alpha-tocopherol, and gamma-tocopherol were measured by high performance liquid chromatography. RESULTS: There was no significant differences of IL-6 levels in umbilical venous plasma between women with normal and preeclampsia (2.79+/-0.21 vs. 2.94+/-0.17 ng/ml). TNF-alpha levels in umbilical venous plasma of women with preeclampsia were significantly higher than that of women with preeclampsia (3.04+/-0.01 vs. 1.40+/-0.01 ng/ml, p<0.01). Lipid peroxide levels in umbilical venous plasma of women with preeclampsia were significantly higher than that of women with normal pregnancy (7.32+/-0.09 vs. 5.18+/-0.14, p<0.01). The ORAC values in umbilical venous plasma of women with preeclampsia were significantly lower than that of women with normal pregnancy (12,836.5+/-249.4 vs. 10,490.2+/-276.9 U/ml, p<0.05). Ascorbic acid levels in umbilical venous plasma of women with preeclampsia were significantly lower than those of women with normal pregnancy (320.2+/-48.5 vs. 538.5+/-68.2 nmol/ml, p<0.05). CONCLUSION: The above results in umbilical venous plasma suggest that the imbalance of lipid peroxidation and antioxidant activity in placenta is involved in the pathophysiology of preeclampsia. Increased TNF-alpha in the umbilical venous plasma showed inflammatory reaction in the placenta would be one of the cause of preclampsia. An antioxidant vitamin, ascorbic acid, may act an important antioxidant factor in preeclampsia.


Subject(s)
Female , Humans , Pregnancy , alpha-Tocopherol , Ascorbic Acid , Chromatography, Liquid , gamma-Tocopherol , Immunoassay , Interleukin-6 , Lipid Peroxidation , Placenta , Plasma , Pre-Eclampsia , Tumor Necrosis Factor-alpha , Vitamin A , Vitamins
15.
Article in Korean | WPRIM (Western Pacific) | ID: wpr-178375

ABSTRACT

OBJECTIVE: This study was performed to compare the prooxidative activity stimulating the protein carbonyl formation by cephalosporins in the umbilical venous and placenta of preeclampsia with that of normal pregnancy. METHODS: Lipid peroxide levels in the umbilical venous plasma and placental tissue homogenates of normal pregnancy (n=12) and preeclampsia (n=12) were measured by thiobarbituric acid reaction. The basal protein carbonyl contents in the umbilical venous plasma and placental tissue homogenates of normal pregnancy (n=12) and preeclampsia (n=12) were determined by the 2,4-dinitrophenylhydrazine (DNPH) method. After samples of them were mixed and incubated up to 5 hours with 0.2 mL of 1 mM moxalactam or cephalothin, the protein carbonyl contents in them were measured by DNPH. RESULTS: Protein carbonyls formation by moxalactam and cephalothin in the umbilical venous plasma and of women with preeclampsia were significantly higher than that of women with normal pregnancy (8.5+/-2.0 vs. 6.6+/-1.4 nmol/mg protein, p<0.05, 7.6+/-1.6 vs. 6.2+/-1.2 nmol/mg protein, p<0.05). Protein carbonyls formation by moxalactam and cephalothin in the placental tissue homogenates of women with preeclampsia were significantly higher than that of women with normal pregnancy (17.6+/-5.3 vs. 13.0+/-4.2 nmol/mg protein, p<0.05, 16.1+/-5.2 vs. 12.5+/-4.4 nmol/mg protein, p<0.05). There were significant positive correlations between lipid peroxide and cephalosporins induced protein carbonyls levels of umbilical venous plasma, and placental tissue homogenates (p<0.01). CONCLUSION: These results suggest that increase in the prooxidative activity stimulating the oxidative modification of proteins in placenta may be involved in the pathogenesis of preecalmpsia.


Subject(s)
Female , Humans , Pregnancy , Cephalosporins , Cephalothin , Moxalactam , Placenta , Plasma , Pre-Eclampsia , Protein Carbonylation
16.
Article in Korean | WPRIM (Western Pacific) | ID: wpr-48882

ABSTRACT

OBJECTIVE: The aim of this study was to measure circulating levels of nitric oxide metabolites (nitrites) in the uteroplacental, fetoplacental, and peripheral circulation in women with normal pregnancy and preeclampsia. METHODS: Two groups of pregnant women were included : 20 patients with preeclampsia and 18 normotensive women. At cesarean, blood samples were taken from the antecubital vein and uterine vein draining the placental site before delivery of the baby, and the umbilical vein after delivery of the baby. Plasma nitric oxide concentrations were determined with the Griess reaction by measuring combined oxidation products of nitric oxide, plasma nitrite and nitrate after reduction with nitrate reductase. RESULTS: Significantly higher serum nitrite concentrations were found in umbilical (46.53+/-22.01 vs. 17.51+/-7.43 M/L, p<0.05), uterine (51.78+/-14.19 vs. 21.23+/-11.6 M/L, p<0.05) and antecubital (66.41+/-20.87 vs. 21.26+/-9.54 M/L, p<0.05) venous plasma in the preeclamptic group compared with the control group. CONCLUSION: We observe higher levels of nitirc oxide metabolites in the uteroplacental, fetoplacental, and peripheral circulation in women with preeclampsia than in normal pregnancy. These results support the hypothesis that increased nitric oxide production may be a compensatory response to improve blood flow and offset the pathologic effects of preeclampsia.


Subject(s)
Female , Humans , Pregnancy , Nitrate Reductase , Nitric Oxide , Plasma , Pre-Eclampsia , Pregnant Women , Umbilical Veins , Veins
17.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-675995

ABSTRACT

Objective To evaluate the precision of BREEZE~(TM) glucose monitor and correlation of glucose measurements between fingertip capillary whole blood glucose(CBG)using BREEZE~(TM) glucose monitor and venous plasma glucose(VPG)using autoanalyzer.Methods All samples of venous plasma and fingertip blood from 188 diabetes or non-diabetes patients were detected for glucose level at fasting,30,60 and 120 min postprandial.BREEZE~(TM) glucose monitor and autoanalyzer measured CBG and VPG respectively.Intra-and inter- coefficients of variations were determined using 10 BREEZE~(TM) glucose monitors with normal,slight high and high glucose levels for the three lots of strips.Results The correlation coefficients between CBG and VPG were all higher than 0.950 at fasting and different postprandial time.98.94% of all measurements were in the A zone when using error-grid analysis.The relevant differences between CBG and VPG were less than 5% at different blood glucose concentrations.The intra-and inter-coefficients of variations of blood glucose values at different blood glucose concentrations using different lots of strips were within 5%.Conclusion BREEZE~(TM) glucose monitor provides high accurate and precise glucose readings on fasting and different postprandial time points over a variety of blood glucose concentrations.

SELECTION OF CITATIONS
SEARCH DETAIL