Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 944
Filter
1.
Phys Eng Sci Med ; 2024 Jul 02.
Article in English | MEDLINE | ID: mdl-38954381

ABSTRACT

A fundamental parameter to evaluate the beam delivery precision and stability on a clinical linear accelerator (linac) is the focal spot position (FSP) measured relative to the collimator axis of the radiation head. The aims of this work were to evaluate comprehensive data on FSP acquired on linacs in clinical use and to establish the ability of alternative phantoms to detect effects on patient plan delivery related to FSP. FSP measurements were conducted using a rigid phantom holding two ball-bearings at two different distances from the radiation source. Images of these ball-bearings were acquired using the electronic portal imaging device (EPID) integrated with each linac. Machine QA was assessed using a radiation head-mounted PTW STARCHECK phantom. Patient plan QA was investigated using the SNC ArcCHECK phantom positioned on the treatment couch, irradiated with VMAT plans across a complete 360° gantry rotation and three X-ray energies. This study covered eight Elekta linacs, including those with 6 MV, 18 MV, and 6 MV flattening-filter-free (FFF) beams. The largest range in the FSP was found for 6 MV FFF. The FSP of one linac, retrofitted with 6 MV FFF, displayed substantial differences in FSP compared to 6 MV FFF beams on other linacs, which all had FSP ranges less than 0.50 mm and 0.25 mm in the lateral and longitudinal directions, respectively. The PTW STARCHECK phantom proved effective in characterising the FSP, while the SNC ArcCHECK measurements could not discern FSP-related features. Minor variations in FSP may be attributed to adjustments in linac parameters, component replacements necessary for beam delivery, and the wear and tear of various linac components, including the magnetron and gun filament. Consideration should be given to the ability of any particular phantom to detect a subsequent impact on the accuracy of patient plan delivery.

2.
Sensors (Basel) ; 24(13)2024 Jun 26.
Article in English | MEDLINE | ID: mdl-39000944

ABSTRACT

The ANTHEM (Advanced Technologies for Human-centered Medicine) Radio-Frequency Quadrupole (RFQ) will employ eight coaxial power couplers, which will be magnetically coupled to the device through a loop antenna. The coupler design can support up to 140 kW in continuous wave operation. This paper presents the design of the cavity used for high-power testing, with the primary objectives of both optimizing the coupling between the couplers and ensuring operations at the designated operating frequency. Furthermore, the paper encompasses thermal and structural assessments conducted through numerical simulations.

3.
Phys Imaging Radiat Oncol ; 31: 100597, 2024 Jul.
Article in English | MEDLINE | ID: mdl-39006756

ABSTRACT

Current online adaptive radiotherapy (oART) workflows require dedicated equipment. Our aim was to develop and implement an oART workflow for a C-arm linac which can be performed using standard clinically available tools. A workflow was successfully developed and implemented. Three patients receiving palliative radiotherapy for bladder cancer were treated, with 33 of 35 total fractions being delivered with the cone-beam computed tomography (CBCT)-guided oART workflow. Average oART fraction duration was 24 min from start of CBCT acquisition to end of beam on. This work shows how oART could be performed without dedicated equipment, broadening oART availability for application at existing treatment machines.

4.
Materials (Basel) ; 17(13)2024 Jul 07.
Article in English | MEDLINE | ID: mdl-38998435

ABSTRACT

This study investigates how scattering foil materials and sampling holder placement affect electron energy distribution in electron beams from a modified medical linear accelerator for FLASH radiotherapy. We analyze electron energy spectra at various positions-ionization chamber, mirror, and jaw-to evaluate the impact of Cu, Pb-Cu, Pb, and Ta foils. Our findings show that close proximity to the source intensifies the dependence of electron energy distribution on foil material, enabling precise beam control through material selection. Monte Carlo simulations are effective for designing foils to achieve desired energy distributions. Moving the sampling holder farther from the source reduces foil material influence, promoting more uniform energy spreads, particularly in the 0.5-10 MeV range for 12 MeV electron beams. These insights emphasize the critical role of tailored material selection and sampling holder positioning in optimizing electron energy distribution and fluence intensity for FLASH radiotherapy research, benefiting both experimental design and clinical applications.

5.
Surg Neurol Int ; 15: 223, 2024.
Article in English | MEDLINE | ID: mdl-38974554

ABSTRACT

Background: Radiation-induced changes (RICs) post-stereotactic radiosurgery (SRS) critically influence outcomes in arteriovenous malformation (AVM) treatments. This study aimed to identify predictors of RICs, described the types and severity of RICs, and assessed their impact on patient's functional outcomes to enhance risk assessment and treatment planning for AVM patients. Methods: This retrospective study analyzed 87 AVM patients who underwent SRS at Hospital Kuala Lumpur between January 2015 and December 2020. RICs were identified through detailed magnetic resonance imaging evaluations, and predictive factors were determined using multiple logistic regression. Functional outcomes were assessed with the modified Rankin scale (mRS). Results: Among the cohort, 40.2% developed RICs, with radiological RICs in 33.3%, symptomatic RICs in 5.7%, and permanent RICs in 1.1%. Severity categorization revealed 25.3% as Grade I, 13.8% as Grade II, and 1.1% as Grade III. Notably, higher Pollock-Flickinger scores and eloquence location were significant predictors of RIC occurrence. There was a significant improvement in functional outcomes post-SRS, with a marked decrease in non-favorable mRS scores from 8.0% pre-SRS to 1.1% post-SRS (P = 0.031). Conclusion: The study identified the eloquence location and Pollock-Flickinger scores as predictors of RICs post-SRS. The significant reduction in non-favorable mRS scores post-SRS underscores the efficacy of SRS in improving patient outcomes. Their results highlighted the importance of personalized treatment planning, focusing on precise strategies to optimize patient outcomes in AVM management, reducing adverse effects while improving functional outcomes.

6.
Front Oncol ; 14: 1358487, 2024.
Article in English | MEDLINE | ID: mdl-38863634

ABSTRACT

Introduction: The ability to dynamically adjust target contours, derived Boolean structures, and ultimately, the optimized fluence is the end goal of online adaptive radiotherapy (ART). The purpose of this work is to describe the necessary tests to perform after a software patch installation and/or upgrade for an established online ART program. Methods: A patch upgrade on a low-field MR Linac system was evaluated for post-software upgrade quality assurance (QA) with current infrastructure of ART workflow on (1) the treatment planning system (TPS) during the initial planning stage and (2) the treatment delivery system (TDS), which is a TPS integrated into the delivery console for online ART planning. Online ART QA procedures recommended for post-software upgrade include: (1) user interface (UI) configuration; (2) TPS beam model consistency; (3) segmentation consistency; (4) dose calculation consistency; (5) optimizer robustness consistency; (6) CT density table consistency; and (7) end-to-end absolute ART dose and predicted dose measured including interruption testing. Differences of calculated doses were evaluated through DVH and/or 3D gamma comparisons. The measured dose was assessed using an MR-compatible A26 ionization chamber in a motion phantom. Segmentation differences were assessed through absolute volume and visual inspection. Results: (1) No UI configuration discrepancies were observed. (2) Dose differences on TPS pre-/post-software upgrade were within 1% for DVH metrics. (3) Differences in segmentation when observed were small in general, with the largest change noted for small-volume regions of interest (ROIs) due to partial volume impact. (4) Agreement between TPS and TDS calculated doses was 99.9% using a 2%/2-mm gamma criteria. (5) Comparison between TPS and online ART plans for a given patient plan showed agreement within 2% for targets and 0.6 cc for organs at risk. (6) Relative electron densities demonstrated comparable agreement between TPS and TDS. (7) ART absolute and predicted measured end-to-end doses were within 1% of calculated TDS. Discussion: An online ART QA program for post-software upgrade has been developed and implemented on an MR Linac system. Testing mechanics and their respective baselines may vary across institutions, but all necessary components for a post-software upgrade QA have been outlined and detailed. These outlined tests were demonstrated feasible for a low-field MR Linac system; however, the scope of this work may be applied and adapted more broadly to other online ART platforms.

7.
J Environ Radioact ; 278: 107470, 2024 Jun 08.
Article in English | MEDLINE | ID: mdl-38852497

ABSTRACT

Chlorine 36 (36Cl) is a radionuclide of natural and anthropogenic origin, mainly used as a tracer in geochemical studies. Owing to analytical constraints and its low environmental levels, knowledge of 36Cl behavior in the environment is still very limited. In this study, we use environmental measurements to report for the first time the wet deposition fluxes of 36Cl downwind an anthropogenic source, the Orano nuclear reprocessing plant, which chronically emits 36Cl into the environment. Measurements of 36Cl in rainwater samples at our study site were 1-2 orders of magnitude above the environmental background. The isotope ratios 36Cl/Cl of the samples and the 36Cl content in the rainwater averaged 2.3x10-12 at at-1 and 1.7x108 at l-1 respectively. A decrease in these levels was observed 20 km away from the study site, outside the plant's gas plume, indicating that the marking of 36Cl on the study site is related to the plant discharges. Over the sampling period, wet deposition fluxes at the study site averaged 3.4x103 at m-2s-1, with significant values measured when precipitations scavenge the plant's gas plume down onto our study site. Analysis of these fluxes also revealed the presence of a significant rainout phenomenon in the study area. These results provide new data on the wet deposition flux of 36Cl and will thus enable better assessment of impact studies in a context of decommissioning or accidents involving nuclear power plants.

8.
Surg Neurol Int ; 15: 181, 2024.
Article in English | MEDLINE | ID: mdl-38840612

ABSTRACT

Background: Frameless image-guided radiosurgery (IGRS) is an effective and non-invasive method of treating patients who are unresponsive to medical management for trigeminal neuralgia (TN). This study evaluated the use of frameless IGRS to treat patients with medically refractory TN. Methods: We performed a retrospective review of records of 116 patients diagnosed with TN who underwent frameless IGRS using a linear accelerator (LINAC) over 10 years (March 2012-February 2023). All patients had failed medical management for TN. Facial pain was graded using the Barrow Neurological Institute (BNI) scoring system. Each patient received a BNI score before frameless IGRS and following treatment. Failure was defined as a BNI score IV-V at the last follow-up and/or undergoing a salvage procedure following IGRS. Results: All patients had a BNI score of either IV or V before the frameless IGRS. The mean follow-up duration for all 116 patients following IGRS was 44.1 months. Most patients (81 [69.8%]) had not undergone surgery (microvascular decompression [MVD] or rhizotomy) or stereotactic radiosurgery (SRS) for TN before frameless IGRS. A total of 41 (35.3%) patients underwent a salvage procedure (MVD, rhizotomy, or an additional IGRS) following frameless IGRS. The mean duration between the initial frameless IGRS and salvage procedure was 20.1 months. At the last follow-up, a total of 110 (94.8%) patients had a BNI score of I-III. No complications were reported after the frameless IGRS. The BNI score at the last follow-up was lower compared to the initial BNI for patients regardless of prior intervention (P < 0.001). Patients who failed IGRS had a higher BNI score at the last follow-up compared to those who did not fail IGRS (2.8 vs. 2.5, P = 0.05). Patients with pain relief had a shorter follow-up compared to those with pain refractory to SRS (38.0 vs. 55.1, P = 0.005). Conclusion: In this large cohort of patients with medically refractory TN, frameless IGRS resulted in durable pain control in the majority of patients without any toxicity.

10.
Med Phys ; 2024 Jun 28.
Article in English | MEDLINE | ID: mdl-38941539

ABSTRACT

BACKGROUND: An ultra-high dose rate (UHDR) electron accelerator for FLASH radiotherapy (RT) produces very intense bremsstrahlung by the interaction of the electron beam with objects both inside and outside of the accelerator. The bremsstrahlung dose per pulse is typically 1-2 orders of magnitude larger than that of conventional RT x-ray treatment of the same energy, and for electron energies above 10 MeV, the bremsstrahlung produces substantially more induced radioactivity outside the accelerator than for conventional RT. Therefore, a thorough radiation safety assessment is mandatory prior to the operation of a UHDR electron accelerator. PURPOSE: To evaluate the radiation safety of a prototype FLASH-enabled Varian TrueBeam accelerator and to develop a general framework for assessment of all key radiation safety properties of a UHDR electron accelerator for FLASH RT. METHODS: Production of bremsstrahlung and induced radioactivity by a UHDR electron accelerator is modeled by various analytical methods. The analytical modeling is compared with National Institute of Standards and Technology (NIST) bremsstrahlung yield data as well as measurements of primary bremsstrahlung outside the bunker and induced radioactivity of irradiated thick targets for a FLASH-enabled 16 MeV Varian TrueBeam electron accelerator. In addition, the analytical modeling is complemented by measurements of secondary bremsstrahlung inside/outside the bunker and neutrons at the maze entrance. RESULTS: Calculated bremsstrahlung yields deviate maximum 8.5% from NIST data, and all measurements of primary bremsstrahlung and induced radioactivity agree with calculations, validating the analytical tools. In addition, it is found that scattering foil bremsstrahlung dominates primary bremsstrahlung and the main source of secondary bremsstrahlung is the irradiated object outside the accelerator. It follows that primary and secondary bremsstrahlung outside the bunker can be calculated using the same simple formalism as that used for conventional RT. Measured primary bremsstrahlung tenth-value layers for concrete of the simple formalism are in good agreement with NCRP and IAEA data, while measured secondary bremsstrahlung tenth-value layers for concrete are considerably lower than NCRP and IAEA data. All calculations and measurements form a general framework for assessment of all key radiation safety properties of a UHDR electron accelerator. CONCLUSIONS: The FLASH-enabled Varian TrueBeam accelerator is safe for normal operation (max. 99 pulses per irradiation) in a bunker designed for at least 15 MV conventional x-ray treatment unless the UHDR workload is much larger than the x-ray workload. A similar finding applies to other UHDR electron accelerators. However, during beam tuning, radiation survey, or other tests with extended irradiation time, the UHDR workload may become very large, necessitating the implementation of additional safety measures.

11.
J Appl Clin Med Phys ; : e14433, 2024 Jun 23.
Article in English | MEDLINE | ID: mdl-38923344

ABSTRACT

PURPOSE: The IC Profiler (ICP) manufactured by Sun Nuclear Corporation (SNC) is an ionization chamber (IC) array used for linear accelerator dosimetry measurements. Previous work characterized response of the ICP under various conditions, but there is limited work of its implementation into monthly QA measurement procedures. This work quantifies ICP accuracy and variables that affect accuracy for beam output measurements, and demonstrates feasibility of using the ICP for all recommended monthly dosimetry measurements. METHODS: A total of 1985 output measurements on six Varian TrueBeam and Edge linear accelerators were performed using three ICP with quad wedges (QWs) and were compared with conventional IC measurements. The accuracy of the ICP for beam output was characterized as the difference between the ICP and IC. Variables that affect ICP accuracy, including gain settings, calibrations, and template baselining as well as machine or energy-specific bias were investigated. Measurements of profile constancy, energy, dose rate constancy, wedge factors, and gating were performed. RESULTS: The initially observed mean output difference between the ICP and IC was 0.16% (0.61%). When gain settings were optimized, the output difference accuracy improved to -0.02% (0.38%). The output accuracy of the ICP was not dependent on array, dose, temperature and pressure calibrations, or template baselining. Statistically, ICP output accuracy was dependent on machine and beam energy, but clinically, all measurements fell within 0.5% of unity. ICP measurements of energy, dose rate constancy, and wedge factors matched passing results with conventional IC in water measurements. Gating and beam profile constancy measurements demonstrated good stability using the ICP. Finally, monthly dosimetry QA using ICP was completed in an average of 33 min compared to 66 min using the IC. CONCLUSION: This work demonstrated the feasibility and efficiency of using the ICP, with specific considerations, as a measurement device for dosimetric linear accelerator monthly QA.

12.
Eur J Heart Fail ; 2024 Jun 26.
Article in English | MEDLINE | ID: mdl-38924328

ABSTRACT

AIMS: Compared with those without obesity, patients with obesity-related heart failure with preserved ejection fraction (HFpEF) have worse symptoms, haemodynamics, and outcomes. Current weight loss strategies (diet, drug, and surgical) work through decreased energy intake rather than increased expenditure and cause significant loss of skeletal muscle mass in addition to adipose tissue. This may have adverse implications for patients with HFpEF, who already have reduced skeletal muscle mass and function and high rates of physical frailty. Mitochondrial uncoupling agents may have unique beneficial effects by producing weight loss via increased catabolism rather than reduced caloric intake, thereby causing loss of adipose tissue while sparing skeletal muscle. HU6 is a controlled metabolic accelerator that is metabolized to the mitochondrial uncoupling agent 2,4-dinotrophenol. HU6 selectively increases carbon oxidation from fat and glucose while also decreasing toxic reactive oxygen species (ROS) production. In addition to sparing skeletal muscle loss, HU6 may have other benefits relevant to obesity-related HFpEF, including reduced specific tissue depots contributing to HFpEF; improved glucose utilization; and reduction in systemic inflammation via both decreased ROS production from mitochondria and decreased cytokine elaboration from excess, dysfunctional adipose. METHODS: We describe the rationale and design of HuMAIN-HFpEF, a Phase 2a randomized, double-blind, placebo-controlled, dose-titration, parallel-group trial in patients with obesity-related HFpEF to evaluate the effects of HU6 on weight loss, body composition, exercise capacity, cardiac structure and function, metabolism, and inflammation, and identify optimal dosage for future Phase 3 trials. CONCLUSIONS: HuMAIN will test a promising novel agent for obesity-related HFpEF.

13.
Data Brief ; 54: 110554, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38882191

ABSTRACT

To advance high-energy atmospheric physics, studying atmospheric electric fields (AEF) and cosmic ray fluxes as an interconnected system is crucial. At Mt. Argats, simultaneous measurements of particle fluxes, electric fields, weather conditions, and lightning locations have significantly enhanced the validation of models that describe the charge structures of thunderclouds and the mechanics of internal electron accelerators. In 2023, observations of the five largest thunderstorm ground enhancements (TGEs) revealed electric fields exceeding 2.0 kV/cm at elevations just tens of meters above ground-potentially hazardous to rockets and aircraft during launch and charging operations. Utilizing simple yet effective monitoring equipment developed at Aragats, we can mitigate the risks posed by these high-intensity fields. The Mendeley dataset, comprising various measured parameters during thunderstorm activities, enables researchers to perform advanced correlation analysis and uncover complex relationships between these atmospheric phenomena. This study underscores the critical importance of integrated atmospheric studies for ensuring the safety of high-altitude operations and advancing atmospheric science.

14.
Sci Rep ; 14(1): 13315, 2024 06 10.
Article in English | MEDLINE | ID: mdl-38858439

ABSTRACT

Exposure to high, marginally lethal doses or higher of ionizing radiation, either intentional or accidental, results in injury to various organs. Currently, there is only a limited number of safe and effective radiation countermeasures approved by US Food and Drug Administration for such injuries. These approved agents are effective for only the hematopoietic component of the acute radiation syndrome and must be administered only after the exposure event: currently, there is no FDA-approved agent that can be used prophylactically. The nutraceutical, gamma-tocotrienol (GT3) has been found to be a promising radioprotector of such exposure-related injuries, especially those of a hematopoietic nature, when tested in either rodents or nonhuman primates. We investigated the nature of injuries and the possible protective effects of GT3 within select organ systems/tissues caused by both non-lethal level (4.0 Gy), as well as potentially lethal level (5.8 Gy) of ionizing radiation, delivered as total-body or partial-body exposure. Results indicated that the most severe, dose-dependent injuries occurred within those organ systems with strong self-renewing capacities (e.g., the lymphohematopoietic and gastrointestinal systems), while in other tissues (e.g., liver, kidney, lung) endowed with less self-renewal, the pathologies noted tended to be less pronounced and less dependent on the level of exposure dose or on the applied exposure regimen. The prophylactic use of the test nutraceutical, GT3, appeared to limit the extent of irradiation-associated pathology within blood forming tissues and, to some extent, within the small intestine of the gastrointestinal tract. No distinct, global pattern of bodily protection was noted with the agent's use, although a hint of a possible radioprotective benefit was suggested not only by a lessening of apparent injury within select organ systems, but also by way of noting the lack of early onset of moribundity within select GT3-treated animals.


Subject(s)
Dietary Supplements , Radiation-Protective Agents , Animals , Radiation-Protective Agents/pharmacology , Vitamin E/pharmacology , Vitamin E/analogs & derivatives , Acute Radiation Syndrome/prevention & control , Acute Radiation Syndrome/drug therapy , Acute Radiation Syndrome/pathology , Chromans/pharmacology , Male , Radiation Injuries, Experimental/prevention & control , Radiation Injuries, Experimental/pathology , Macaca mulatta , Liver/drug effects , Liver/radiation effects , Liver/pathology
15.
Sci Total Environ ; 945: 174146, 2024 Oct 01.
Article in English | MEDLINE | ID: mdl-38909813

ABSTRACT

The cosmogenic radionuclide 7Be (T1/2: 53.29 days) and 10Be (T1/2: 1.39 My), as unique tracers, play an excellent indicative role in atmospheric environmental changes and Earth surface processes. Currently, their different characteristics and influencing factors in various natural climate environments are still vague. Here, we used a state-of-the-art accelerator mass spectrometry to synchronously measure the ultra-trace 7Be and 10Be in aerosols, obtaining the spatial and temporal variability of daily-resolution atmospheric 7Be and 10Be in different natural climate regions (n = 11) of China. The survey results show that the 10Be and 7Be concentrations in the central/southern regions of China (22-38°N, 85-119°E) in 2020/21 are (0.5-18.7)·104 and (0.4-6.1)·104 atoms·m-3, respectively, with 10Be/7Be ratios of 0.7-3.3. Except for the Tibetan Plateau, there are differences in the concentration thresholds of 10Be and 7Be in various regions, especially in 10Be concentration. These 10Be/7Be thresholds are consistent in areas with an altitude range of 4-3420 m a.s.l and reach their highest values throughout the spring of the year. The analysis results indicate that both 7Be and 10Be are influenced by local meteorological conditions such as rainfall and boundary layer disturbances, while also exhibiting different distribution states. This distribution states is due to the re-suspended soil dust 10Be interference caused by soil wind erosion to varying degrees in different regions, with an average contribution to aerosol 10Be of 5.0 ± 2.6 %-24.2 % ± 13.3 %, and is controlled by local annual rainfall (r = 0.8, p < 0.01). Furthermore, unlike the characteristics of 10Be and 7Be concentrations influenced by local meteorological conditions, the daily variation of corrected 10Be/7Be exhibits independence from meteorological processes other than stratosphere troposphere transport, and its significant seasonal oscillations indicate changes in atmospheric circulation in the East Asian monsoon region.

16.
J Vet Med Sci ; 86(7): 796-800, 2024 Jul 02.
Article in English | MEDLINE | ID: mdl-38839352

ABSTRACT

The control of digital dermatitis (DD) among cattle is crucial; however, effective and environmentally-sound control measures have yet to be identified. From the monitoring data of DD which were recorded during regular hoof trimmings in a farm in Hokkaido, Japan, we detected a decrease in the DD prevalence in a herd where an anaerobic bacterial fermentation enhancer (ABFE) was distributed. The possible effect of ABFE was analyzed using a retrospective repeated cross-sectional design. The prevalence of DD decreased over time in the ABFE-distributed group. Furthermore, a selected regression model indicated the time-dependent enhancement of the decreasing trend. While potential coincidental factors may influence, this study provides a basis for further research on the preventive effect of ABFE against DD.


Subject(s)
Cattle Diseases , Digital Dermatitis , Fermentation , Animals , Cattle , Retrospective Studies , Digital Dermatitis/microbiology , Digital Dermatitis/prevention & control , Cattle Diseases/microbiology , Cattle Diseases/prevention & control , Japan , Cross-Sectional Studies , Bacteria, Anaerobic , Hoof and Claw/microbiology
17.
Appl Radiat Isot ; 211: 111403, 2024 Sep.
Article in English | MEDLINE | ID: mdl-38889530

ABSTRACT

Recently, a new radiation therapy using a high-energy accelerator irradiation vault has attracted significant attention. This therapy is very effective in destroying cancer cells because it uses much higher energy than conventional radiation therapy. Nevertheless, it also has disadvantages due to its high energy and dose, resulting in the generation of secondary radiation such as X-rays and neutrons. In particular, neutrons have a higher radiation weighting factor than photons; therefore, they are more harmful to normal tissues. However, the popular neutron dosimeter CR-39 cannot evaluate high-dose neutrons. This paper proposes a novel method for measuring high-dose neutrons generated during cancer treatment. LR-115, which has low detection efficiency but is expected to be useful for evaluating high-dose neutrons, was used to evaluate the effective dose of neutrons in a high-energy accelerator irradiation room. The results were verified using MCNP 6.2, a Monte Carlo-based particle transport code. This study provides the lower limit for evaluating neutron effective dose using LR-115. The experimental results showed that the neutron effective dose increased linearly with beam current. These findings provide basic data for evaluating neutron effective dose for radiation protection.

18.
J Xray Sci Technol ; 2024 Jun 11.
Article in English | MEDLINE | ID: mdl-38875073

ABSTRACT

BACKGROUND: The polychromatic X-rays generated by a linear accelerator (Linac) often result in noticeable hardening artifacts in images, posing a significant challenge to accurate defect identification. To address this issue, a simple yet effective approach is to introduce filters at the radiation source outlet. However, current methods are often empirical, lacking scientifically sound metrics. OBJECTIVE: This study introduces an innovative filter design method that optimizes filter performance by balancing the impact of ray intensity and energy on image quality. MATERIALS AND METHODS: Firstly, different spectra under various materials and thicknesses of filters were obtained using GEometry ANd Tracking (Geant4) simulation. Subsequently, these spectra and their corresponding incident photon counts were used as input sources to generate different reconstructed images. By comprehensively comparing the intensity differences and noise in images of defective and non-defective regions, along with considering hardening indicators, the optimal filter was determined. RESULTS: The optimized filter was applied to a Linac-based X-ray computed tomography (CT) detection system designed for identifying defects in graphite materials within high-temperature gas-cooled reactor (HTR), with defect dimensions of 2 mm. After adding the filter, the hardening effect reduced by 22%, and the Defect Contrast Index (DCI) reached 3.226. CONCLUSION: The filter designed based on the parameters of Average Difference (AD) and Defect Contrast Index (DCI) can effectively improve the quality of defect images.

19.
Med Dosim ; 2024 May 13.
Article in English | MEDLINE | ID: mdl-38744604

ABSTRACT

When planning a simultaneous integrated boost in breast treatment with sliding window intensity-modulated radiotherapy, the use of an oblique anterior field can be advantageous. To limit the irradiation to the tumor bed on the oblique anterior field, we use the "fixed jaw" option during optimization in Eclipse (v15.6, Varian Medical System). However, this option is not available for Halcyon (Varian Medical System) linear accelerators because the beam-defining collimator is only composed of a dual-layer multileaf collimator (MLC) without any jaw collimator. Hence, the optimizer opens the leaves on all target volumes, and leaves facing the heart or medullary canal may be opened on the oblique anterior field. To avoid this unacceptable behavior, we created an avoidance structure using the Eclipse Scripting Application Programming Interface (ESAPI) to force the optimizer to close the leaves when facing critical organs at risk. The avoidance structure was the whole body of the patient subtracted from every beam path used: the tangential fields collimated to the breast planning target volume (PTV) and the oblique anterior field collimated to the tumor bed PTV. The ESAPI has a built-in method that returns a table of points, drawing the outline of a structure at the isocenter plane of a beam. We used this method to build the avoidance structure. We planned 6 breast cancer patients using this structure, and we were able to meet all dosimetric constraints. All MLC leaves were fully closed outside the tumor bed PTV for the oblique anterior field.

20.
Philos Trans A Math Phys Eng Sci ; 382(2273): 20230208, 2024 Jun 09.
Article in English | MEDLINE | ID: mdl-38736336

ABSTRACT

The selected ice nanoparticle accelerator, SELINA, was used to prepare beams of single ice particles with positive or negative charge. Positively charged particles were prepared from deionized water and 0.05-0.2 molar solutions of sodium chloride in water, and negatively charged ice particles were generated from water without salt. Depending on the electrospray source configuration, the measured particles vary from 50 to 1000 nm in diameter. The kinetic energy per charge for all particles was set to 200 eV by the collisional equilibration in quadrupoles, which resulted in primary velocities up to 600 m/s for the lowest m/z particles. The electrospray ionization and thus particle formation from SELINA become less efficient with increasing salt concentration, resulting in a lower detected particle frequency and size. Good instrument operation is achievable for concentrations below 0.2 M. After we have verified and characterized positively and negatively charged ice particles, we have combined SELINA with a target and time-of-flight spectrometer for a 'proof-of-principle' post acceleration of 120 nm particles towards hypervelocity (v ~ 3000 m/s) and detection of fragments from the particle impact (SELINA-HIMS). General conditions are discussed for the acceleration of particles between 50 and 1000 nm to velocities well above 3000 m/s with SELINA-HIMS instrument. This article is part of the theme issue 'Dust in the Solar System and beyond'.

SELECTION OF CITATIONS
SEARCH DETAIL
...