Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 909
Filter
1.
J Exp Orthop ; 11(3): e12067, 2024 Jul.
Article in English | MEDLINE | ID: mdl-39011084

ABSTRACT

Purpose: Obesity is prevalent, with nearly one-third of the world's population being classified as obese. In patients with high body mass index (BMI)/body mass undergoing total knee arthroplasty (TKA), there is an increase in strain placed on the implant fixation interfaces. As such, component fixation is a potential concern when performing TKA in the obese patient. To address the growing concerns around the longevity of implant fixation, some have advocated cementless over cemented fixation. However, there is no clear consensus on whether a cementless fixation has more favourable outcomes. The aim of this paper was to present a systematic review and meta-analysis of the existing evidence to establish if cementless TKA has a lower rate of aseptic loosening in high BMI patients when compared to cemented TKA procedures. Methods: A systematic review was performed, and the following databases Medical Literature Analysis and Retrieval System Online (1946 to date), PubMed (1966 to date) and Excerpta Medica Database (1974 to date) were searched. All studies comparing cementless to cemented TKA in patients with BMI > 30 were considered. Meta-analysis compared aseptic loosening and all-cause revision between cemented and uncemented implant use in BMI > 30 patients. Results: The search returned 91 articles in total; after duplicates were removed, the yield was 44 studies. Of the remaining studies that were assessed, three studies met the inclusion criteria for meta-analysis. The pooled odds ratio for all-cause revisions was 0.17 (95%, 0.08-0.36) in favour of uncemented implants (p < 0.01). The pooled odds ratio for aseptic loosening was 0.15 (95% confidence interval, 0.02-0.90) in favour of uncemented implants (p = 0.04). Conclusions: Meta-analysis demonstrated a significant decrease in all-cause revisions and revisions for aseptic loosening when using uncemented fixation in high BMI patients when compared to the use of cemented implants. Level of Evidence: The level of evidence is 1 for our systematic review.

2.
Article in English | MEDLINE | ID: mdl-39025356

ABSTRACT

INTRODUCTION: Early reverse total shoulder arthroplasty (RTSA) designs demonstrated high glenoid baseplate complication and revision rates. While contemporary designs have reduced the incidence of glenoid baseplate failures, there are reports of elevated failure risks in RTSA with glenoid bone grafting within the first 2 years. This study aims to evaluate the incidence and etiology of aseptic glenoid baseplate failure with a contemporary central screw baseplate. The null hypothesis is that majority of the baseplate failure occurs within the first 2 years and use of glenoid bone grafting does not lead to higher risk of baseplate failure. METHODS: In 2014 - 2019, 753 consecutive patients who underwent primary RSA using the same inlay press-fit humeral stem and monoblock central screw baseplate were retrospectively reviewed. Fracture and septic arthropathy cases were excluded. All patients underwent preoperative radiographic and computed tomography evaluation. If there was significant glenoid erosion (Walch A2, B2, B3, C1, C2, E2, E3, and/or E4 variants), patient-specific structural glenoid bone grafting was performed. All patients underwent standardized radiographic follow-up and failure was strictly defined as any hardware breakage and/or shift in glenoid baseplate position. Failures were defined as "early" if occurring within 2 years and "late" if occurring greater than 2 years after surgery. Comparative analysis was performed to evaluate demographics, glenoid graft use, and graft union rates between the cohorts. RESULTS: There were 23 patients with baseplate failures (23/753, 3.0%) at mean of 23 months. Twenty-two failures (96%) occurred in patients who received structural glenoid bone grafting. Only 1 failure (0.2%) occurred when bone grafting was not indicated (p<0.001). The most common failure pattern was associated with B2 glenoid (16/23, 70%). There were 5 (22%) early failures and 18 (78%) late failures. There were no differences in any patient demographic characteristics between cohorts. All 5 early failures had graft nonunion and 4/5 occurred without trauma. In the 18 late failures , 9/18 (50%) occurred without trauma (p=0.135). Seventeen of these patients had glenoid grafting, of which 9/17 (53%) had graft nonunion. CONCLUSIONS: Contemporary RTSA glenoid baseplate designs have an acceptably low incidence of failure. However, the addition of structural bone graft to correct glenoid wear leads to higher aseptic baseplate failure rate. The majority of these patients suffer failure after the 2-year postoperative mark, highlighting the necessity of longer follow-up. Further analysis is necessary to quantify glenoid characteristics (severity of glenoid erosion, critical size of graft) associated with failure.

3.
Arthroplast Today ; 27: 101433, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38946925

ABSTRACT

Background: This study aimed to investigate the relationship between 3-dimensional (3D) alignment and postoperative bone mineral density (BMD) changes with Accolade II tapered wedge stems, which have a different proximal shape from other tapered wedge stems, up to 5 years after primary total hip arthroplasty. Methods: We retrospectively analyzed the hips of 89 patients who underwent total hip arthroplasty using the second-generation proximally coated cementless stem (Accolade II; Stryker Orthopedics, Mahwah, NJ) at our institution from 2014 to 2018 over a 5-year follow-up. We evaluated the relationship between stem alignment, measured using 3D-templating software, and BMD changes in the 7 Gruen zones and compared the data with those from a former study using other short taper-wedge stems. Results: BMDs in zones 1 and 7 continued to decrease gradually every year after surgery, and BMD in zone 7 showed the largest decrease (21%) from baseline over 5 years. No correlation was found between stem alignment (varus/valgus, flexion/extension, and anteversion/retroversion) and changes in BMD in each zone over 5 years. Conclusions: Our data showed no correlation between 3D stem alignment and changes in BMD in each Gruen zone over 5 years. This suggests that the Accolade II stem may fit better into any shape of the proximal medullary canal because of its unique characteristics.

4.
Article in English | MEDLINE | ID: mdl-38967777

ABSTRACT

BACKGROUND: In recent years, the indication for cementless short stem total hip arthroplasty (THA) has been widened to elderly patients as they might profit by the advantages of the short-curved implant design as well. Therefore, this study was conducted to evaluate the clinical and radiological outcome of a cementless short stem in elderly patients (≥ 75 years) compared to a young control group (≤ 60 years). METHODS: A retrospective cohort of 316 THAs performed between 2014 and 2017 was prospectively examined. In all patients a cementless, curved short stem and press-fit cup (Fitmore® stem; Allofit®/-S cup; both ZimmerBiomet, Warsaw, IN, USA) were implanted via a minimally-invasive anterolateral approach. Clinical and radiological outcome as well as rate of complications and revision were assessed. RESULTS: In total, 292 patients have been included for analysis of complications and revisions (Øfollow-up: 4.5 years) and 208 patients for clinical and radiological outcome (Øfollow-up: 4.4 years). Complication rate was significantly increased in elderly patients (13.7% vs. 5.8%, p = 0.023), while the revision rate was increased without statistical significance (5.2% vs. 2.2%, p = 0.169). Periprosthetic fractures occurred significantly higher in the elderly patients (5.2% vs. 0.7%; p = 0.026). Both groups showed a comparable clinical outcome in the Harris Hip Score (93.7 vs. 91.9; p = 0.224), Oxford Hip Score (44.5 vs. 43.7; p = 0.350), Forgotten Joint Score (81.7 vs. 81.5; p = 0.952) and WOMAC (7.4 vs. 9.3; p = 0.334). CONCLUSION: Cementless short stem total hip arthroplasty shows a comparable clinical and radiological outcome in patients over 75 years of age compared to younger patients under 60 years of age. However, cementless shorts stem THA shows an increased rate of overall complications and periprosthetic fractures in elderly patients over 75 years of age. Cemented fixation of the femoral component should be considered in patients over 75 years of age. LEVEL OF EVIDENCE: III Case-controlled study. TRIAL REGISTRATION: Observational study without need for trial registration due to ICMJE criteria.

5.
Arthroplasty ; 6(1): 38, 2024 Jun 21.
Article in English | MEDLINE | ID: mdl-38907318

ABSTRACT

BACKGROUND: The use of long stems for severe femoral bone defects is suggested by many scholars, but it is associated with further bone loss, intraoperative fracture, increased surgical trauma, and complications. With better bone retention, simple and quick surgical procedures, and minimal complications, the short cementless stems with a tapered rectangular shape may be an alternative for femoral revision. This study aimed to evaluate the results of this type of stem in treating selected Paprosky II-IV bone defects. METHODS: This retrospective study included 73 patients (76 hips involved) who underwent conservative femoral revision using the short cementless stems with a tapered rectangular shape between January 2012 and December 2020. The preoperative femoral bone defects were identified as follows: 54 cases of type II, 11 cases of type IIIA, 7 cases of type IIIB, and 4 cases of type IV. Indications for revision included aseptic loosening (76.3%) and prosthetic joint infection (23.7%). Six cementless stems with a tapered rectangular shape from three companies were used in all patients. Among them, SLR-Plus, SL-Plus MIA, and Corail stems were employed in most patients (40.8%, 23.7%, and 17.1%, respectively). The average length of these stems measured 171.7 mm (SD 27 mm; 122-215 mm). Radiographic results, Harris hip scores (HHS), complications, and survivorship were analyzed. The follow-up lasted for 7 years on average (range 3-11 years). RESULTS: The subsidence was observed in three hips (3.9%), and all stems achieved stable bone ingrowth. Proximal femoral bone restoration in the residual osteolytic area was found in 67 hips (88.2%), constant defects in nine hips (11.8%), and increasing defects in 0 cases. There was no evidence of stem fractures and stem loosening in this series. The mean HHS significantly improved from 32 (range 15-50) preoperatively to 82 (range 68-94) at the last follow-up (t = - 36.297, P < 0.001). Five hips developed prosthesis-related complications, including three infection and two dislocation cases. The mean 5- and 10-year revision-free survivorships for any revision or removal of an implant and reoperation for any reason were 94.6% and 93.3%, respectively. Both mean 5- and 10-year revision-free survivorships for aseptic femoral loosening were 100%. CONCLUSION: Conservative femoral revision using short cementless stems with a tapered rectangular shape can provide favorable radiographic outcomes, joint function, and mid-term survivorship with minimal complications. Of note, a sclerotic proximal femoral bone shell with continued and intact structure and enough support strength is the indication for using these stems.

6.
Arthroplast Today ; 27: 101432, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38882465

ABSTRACT

Background: Initial stability of cementless stems is important to minimize the risk of subsidence, pain, and periprosthetic fracture after total hip arthroplasty (THA). Collared stems improve initial component stability when contacting the femoral calcar. Direct contact is not always achieved, and collared stem performance has not been studied in this context. We hypothesized that collared stems achieving direct contact would demonstrate reduced subsidence. Methods: A single-surgeon retrospective study of 482 consecutive primary THAs implanted between February 2020 and May 2023 using collared cementless stems was performed. The 2 cohorts included stems with initial collar-calcar contact vs stems without. Subsidence was evaluated by comparing intraoperative fluoroscopy to postoperative 8-week radiographs. Binary logistic regression identified independent risk factors for subsidence. Chi-square tests were used for categorical variables and t-tests for continuous variables. Results: Of stems, 63.9% achieved initial collar-calcar contact, while 36.1% did not. The rate (1.3% vs 19.0%; P < .001) and magnitude (0.02 mm, range 0-3 mm vs 0.35 mm, range 0-3 mm; P < .001) of subsidence were significantly higher among stems without initial contact. Stems without initial collar-calcar contact (P < .001) and male gender (P = .007) were independent risk factors for subsidence. Two patients with initial contact had nondisplaced calcar cracks and <3 mm of subsidence at 4 weeks, which healed with protected weight-bearing. Stem survivorship was 100% in both groups, with all achieving osteointegration and none needing revision. Conclusions: Excellent performance of collared cementless stems was observed at 8 weeks after primary THA. Initial collar-calcar contact lowered the risk and magnitude of minor subsidence but did not affect survivorship or fracture risk. Level of Evidence: Level III.

7.
J Arthroplasty ; 2024 Jun 06.
Article in English | MEDLINE | ID: mdl-38851406

ABSTRACT

BACKGROUND: The present study aimed to identify the risk factors of periprosthetic femoral fracture (PFF) after cementless total hip arthroplasty and rank them based on importance. METHODS: The age, sex, body mass index (BMI), osteoporosis, canal flare index (CFI), canal bone ratio (CBR), canal calcar ratio (CCR), stem design, and stem canal fill ratio (P1, P2, P3, and P4) of the proximal femoral medullary cavity of 111 total hip arthroplasty patients who had PFF and 388 who did not have PFF were analyzed. Independent-samples student t-tests were used for continuous variables, and Chi-square tests were used for categorical variables. The importance rankings of influencing factors were assessed using a random forest algorithm. Dimensionally reduced variables were then incorporated into a binary logistic regression model to determine the PFF-related risk factors. RESULTS: The mean age, BMI, CBR, CCR, and incidence of osteoporosis were higher in cases of PFF (all P < .001), while the mean CFI, P1, P2, P3, and P4 were lower in cases of PFF (P < .001, P = .033, P = .008, P < .001, and P < .001, respectively). Additionally, the stem design was also statistically associated with PFF (P < .001). Multivariate logistic regression revealed that advanced age, higher BMI, osteoporosis, stem design, lower CFI, higher CBR, higher CCR, lower P1, lower P2, lower P3, and lower P4 were the risk factors of PFF (P < .001, P < .001, P < .001, P < .001, P < .001, P = .010, P < .001, P = .002, P < .001, P < .001, and P = .007, respectively). The ranked importance of the risk factors for PFF was P3, CFI, osteoporosis, CBR, age, P4, P1, stem design, CCR, BMI, and P2. CONCLUSIONS: Lower P3, lower CFI, osteoporosis, higher CBR, advanced age, lower P4, lower P1, stem design, higher CCR, higher BMI, and lower P2 increased the risk of PFF.

8.
BMC Vet Res ; 20(1): 222, 2024 May 24.
Article in English | MEDLINE | ID: mdl-38783269

ABSTRACT

BACKGROUND: Biomedtrix BFX® cementless total hip replacement (THR) requires the use of femoral broaches to prepare a press-fit envelope within the femur for subsequent stem insertion. Current broaches contain teeth that crush and remove cancellous bone; however, they are not particularly well-suited for broaching sclerotic (corticalized) cancellous bone. In this study, three tooth designs [Control, TG1 (additional V-grooves), TG2 (diamond tooth pattern)] were evaluated with a quasi-static testing protocol and polyurethane test blocks simulating normal and sclerotic bone. To mimic clinical broaching, a series of five sequential broach insertions were used to determine cumulative broaching energy (J) and peak loads during broach insertion. To determine the effect of broach tooth design on THR stem insertion, a BFX® stem was inserted into prepared test blocks and insertion and subsidence energy and peak loads were determined. RESULTS: Broach tooth design led to significant differences in broaching energy and peak broaching loads in test blocks of both densities. In low density test blocks, TG1 required the lowest cumulative broaching energy (10.76 ±0.29 J), followed by Control (12.18 ±1.20 J) and TG2 (16.66 ±0.78 J) broaches. In high density test blocks, TG1 required the lowest cumulative broaching energy (32.60 ±2.54 J) as compared to Control (33.25 ±2.16 J) and TG2 (59.97 ±3.07 J).  During stem insertion and subsidence testing, stem insertion energy for high density test blocks prepared with Control broaches was 14.53 ± 0.81 J, which was significantly lower than blocks prepared with TG1 (22.53 ± 1.04 J) or TG2 (19.38 ± 3.00 J) broaches. For stem subsidence testing in high density blocks, TG1 prepared blocks required the highest amount of energy to undergo subsidence (14.49 ± 0.49 J), which was significantly greater than test blocks prepared with Control (11.09 ±0.09 J) or TG2 (12.57 ± 0.81 J) broaches. CONCLUSIONS: The additional V-grooves in TG1 broaches demonstrated improved broaching performance while also generating press-fit envelopes that were more resistant to stem insertion and subsidence. TG1 broaches may prove useful in the clinical setting; however additional studies that more closely simulate clinical broach impaction are necessary prior to making widespread changes to THR broaches.


Subject(s)
Arthroplasty, Replacement, Hip , Arthroplasty, Replacement, Hip/veterinary , Arthroplasty, Replacement, Hip/instrumentation , Arthroplasty, Replacement, Hip/methods , Animals , Dogs/surgery , Hip Prosthesis/veterinary , Biomechanical Phenomena , Femur/surgery
9.
Orthop Clin North Am ; 55(3): 333-343, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38782505

ABSTRACT

There is concern for cementless total knee arthroplasty (TKA) in patients with decreased bone mineral density (BMD) due to the potential increase in complications, namely failed in-growth or future aseptic loosening. Some data suggest that advances in cementless prostheses mitigate these risks; however this is not yet born out in long-term registry data. It is crucial to expand our understanding of the prevalence and etiology of osteoporosis in TKA patients, survivorship of cementless implants in decreased BMD, role of bone-modifying agents, indications and technical considerations for cementless TKA in patients with decreased BMD. The purpose of this study is to review current literature and expert opinion on such topics.


Subject(s)
Arthroplasty, Replacement, Knee , Bone Density , Osteoporosis , Humans , Arthroplasty, Replacement, Knee/methods , Arthroplasty, Replacement, Knee/adverse effects , Osteoporosis/complications , Knee Prosthesis/adverse effects , Prosthesis Failure , Prosthesis Design
10.
Orthop Clin North Am ; 55(3): 311-321, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38782503

ABSTRACT

This report provides an updated analysis for patients with osteoporosis following total hip arthroplasty (THA). The comorbidities of alcohol abuse, chronic kidney disease, cerebrovascular disease, obesity, and rheumatoid arthritis continue to be significant risk factors for periprosthetic femur fracture (PPFFx) and aseptic loosening in the population with osteoporosis. Patients with dual-energy x-ray absorptiometric (DEXA) scans were at risk for PPFFx regardless of femoral fixation method, and patients with DEXA scans with cementless fixation were at risk of aseptic loosening after THA. The patient population with severe osteoporosis may have higher risks for aseptic loosening and PPFFx than previously recognized.


Subject(s)
Arthroplasty, Replacement, Hip , Femoral Fractures , Osteoporosis , Periprosthetic Fractures , Prosthesis Failure , Humans , Arthroplasty, Replacement, Hip/adverse effects , Periprosthetic Fractures/etiology , Periprosthetic Fractures/epidemiology , Osteoporosis/etiology , Osteoporosis/complications , Risk Factors , Femoral Fractures/surgery , Femoral Fractures/etiology , Female , Male , Aged , Hip Prosthesis/adverse effects , Absorptiometry, Photon , Middle Aged
11.
SICOT J ; 10: 22, 2024.
Article in English | MEDLINE | ID: mdl-38819292

ABSTRACT

PURPOSE: Controversy exists on the best fixation for total knee arthroplasty (TKA). Non-cemented fixation has been theorized to improve patient outcomes and longevity of implantation but no study has focused on comparison between cemented or cementless posterior-stabilized implants despite being the most commonly or second most frequently utilized implant in most total knee replacement registries. METHODS: Inclusion criteria with observational and interventional papers, and review articles that focused on patients with cementless and cemented PS TKAs were used to analyze outcomes such as implant survivorship, complication, or revision rates. Using a combination of keywords, a systematic search was performed on Medline (PubMed), Embase, and Cochrane Library for Meta-Analysis. RESULTS: When using the specified criteria, only 8 studies were selected for full-text analysis and meta-analysis after eliminating screening duplicates, titles, and abstracts without full-text access. These eight studies contain 1652 patients, 693 in the non-cemented Group, and 959 in the cemented total knee prosthesis Group. The meta-analysis revealed the advantage of cementless fixation over cemented fixation in implant survivorship, with 0.6% and 2.6% of aseptic loosening in each Group. The cumulative survival at 12 years was 97.4% for the cementless Group and 89.2% for the cemented Group. The subgroup with a stem showed a positive outcome for cementless fixation over cemented fixation regarding implant survivorship. No differences between the cemented and cementless TKAs were observed in patient-reported outcomes, revision rates, or radiolucent line development. CONCLUSION: We observed comparable rates for cemented and cementless posterior-stabilized TKAs over a medium-term follow-up period.

12.
Arch Orthop Trauma Surg ; 144(6): 2839-2847, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38739153

ABSTRACT

INTRODUCTION: The choice between a cementless taper wedge stem and a fit-and-fill stem in total Hip arthroplasty (THA) for various proximal femoral morphological types has not been thoroughly evaluated. This study aimed to compare the risk of stem-related complications between these two stem types in Dorr type A, B, and C femurs. MATERIALS AND METHODS: From January 2015 through April 2021, we retrospectively reviewed 1995 cementless THA procedures. We stratified all procedures into three groups: Dorr type A (N = 360, 18.0%), B (N = 1489, 74.7%) and C (N = 146, 7.3%). The primary outcome domain was stem-related complications, including stem subsidence ≥ 3 mm, intraoperative fracture, periprosthetic fracture and aseptic stem loosening. We performed multivariate regression analysis to compare the risk of stem-related complication between the two stem types. Other factors included age, sex, body mass index, diagnosis, age-adjusted Charlson comorbidity index, stem alignment and canal fill ratio. RESULTS: The incidence of stem-related complications in the taper wedge and fit-and-fill stem groups was 4.4% (N = 15) and 6.5% (N = 107), respectively. Fit-and-fill stems showed an increased risk of stem-related complications (aOR: 9.903, 95% CI: 1.567-62.597) only in Dorr type C femurs. No significant difference in risk was observed in Dorr type A and B femurs. Furthermore, the canal fill ratio at the lesser trochanter, 2 cm and 7 cm below the lesser trochanter, did not exhibit an association with stem-related complications in any Dorr type. CONCLUSIONS: Concerning the risk of stem-related complications, the taper wedge stem was a better choice in Dorr type C femurs. However, there was no difference in risk between the taper wedge stem and fit-and-fill stem in Dorr type A and B femurs.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Prosthesis , Postoperative Complications , Prosthesis Design , Humans , Arthroplasty, Replacement, Hip/adverse effects , Arthroplasty, Replacement, Hip/methods , Male , Female , Hip Prosthesis/adverse effects , Retrospective Studies , Middle Aged , Aged , Postoperative Complications/epidemiology , Postoperative Complications/etiology , Prosthesis Failure , Femur/surgery , Risk Factors , Adult , Aged, 80 and over
13.
Arch Orthop Trauma Surg ; 144(6): 2859-2864, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38743114

ABSTRACT

BACKGROUND: Total hip arthroplasty (THA) is the gold standard procedure for patients with end-stage osteoarthritis after failed conservative therapy. Digital templating is commonly employed in preoperative preparation for THA and contributes positively to its outcome. However, the impact of coxa valga and antetorta (CVA) configurations on stem size prediction accuracy remains not reported. Previous studies demonstrated that the size of the lesser trochanter (LT) can be used to determine femoral anteversion on pelvis radiographs. This study investigates the accuracy of preoperative digital templating in predicting stem size in patients with CVA undergoing cementless THA. METHODS: Preoperative radiographs of 620 patients undergoing cementless THA were retrospectively investigated. Radiographs were standardized with patients standing and the leg internally rotated by 15°. A CVA group was established including patients with a CCD angle greater than 140° and a lesser trochanter (LT) size of at least 10 mm for men and 8 mm for women. For the control group, radiographs with a CCD angle ranging from 125-135° and LT size 3-10 mm for men and 3-8 mm for women were selected. Preoperative templating was performed using mediCAD. To reduce confounding factors, case-control matching was carried out for BMI and body height. RESULTS: After case-control matching, a total of thirty-one matches were analyzed. Stem size was underestimated in 74% (23/31) in the CVA and 13% (4/31) in the control group (p < 0.001). Moreover, patients with CVA were more likely to be underestimated by two sizes compared to controls (p < 0.004). In contrast, the exact stem size was predicted more frequently in the control group (p < 0.001). CONCLUSION: Stem size in patients with a CVA configuration are at high risk of being underestimated when using digital templating. These findings can be valuable for guiding in intraoperative decisions and lowering the risk of complications associated with an undersized femoral component.


Subject(s)
Arthroplasty, Replacement, Hip , Femur , Hip Prosthesis , Humans , Female , Arthroplasty, Replacement, Hip/methods , Male , Case-Control Studies , Aged , Middle Aged , Retrospective Studies , Femur/diagnostic imaging , Femur/surgery , Osteoarthritis, Hip/surgery , Osteoarthritis, Hip/diagnostic imaging , Radiography , Aged, 80 and over
14.
Arthroplasty ; 6(1): 21, 2024 May 02.
Article in English | MEDLINE | ID: mdl-38693586

ABSTRACT

BACKGROUND: Unicompartmental knee replacement (UKR) is one of the effective interventions for the treatment of symptomatic knee osteoarthritis. Moreover, it has multiple advantages over total knee arthroplasty (TKA), including reduced intraoperative blood loss, decreased risk of transfusion, and faster recovery. This study aimed to discuss critical technical considerations regarding UKR and some of the controversies and updates. METHODS: We conducted a review to provide an overview of the controversies and technical considerations about UKR in several aspects. Only peer-reviewed articles were included, up to December 2023 using PubMed, Google Scholar, ERIC, and Cochrane database for systematic reviews databases. RESULT: UKR is associated with superior patient-reported clinical and functional outcomes, as well as shorter hospital stays, fewer postoperative complications, and revealed favorable outcomes in patients' return to sport. The choice between mobile- and fixed-bearing prostheses depends, in part, on the surgeon's preference. The mobile-bearing UKR is a less constrained prosthesis and can potentially result in less wear, but it is more technically demanding. While no significant difference between mobile-bearing versus fixed-bearing prostheses, cementless is superior to cemented design. Furthermore, UKR can be a good alternative for high tibial osteotomy (HTO) and still can be considered after a failed HTO. Lastly, recent reviews have shown a revision rate comparable to that of TKA. This is probably influenced by Improved comprehension of the best indications, patient selection criteria, as well as of the design, materials, and technological advances. CONCLUSION: UKR treatment for unicompartmental knee osteoarthritis is secure and effective. Based on clinical and functional outcomes, decreased morbidity and mortality, and cost-effectiveness, long-term studies suggest that UKR is superior to TKA. Further investigation in this area is warranted.

15.
J Clin Med ; 13(9)2024 Apr 29.
Article in English | MEDLINE | ID: mdl-38731155

ABSTRACT

Background: Total hip arthroplasty is one of the most successful orthopedic surgeries; nevertheless, many of these surgeries are the causes of failure, and among them, periprosthetic fractures are one of the major causes of revision. Our study focuses on periprosthetic hip fractures with two different stem designs. The aim of the study was to analyze the obtained results, focusing on the features of periprosthetic stem fractures observed. Methods: We retrospectively reviewed periprosthetic fractures occurring between 2010 and 2023, involving Alloclassic® or CLS® uncemented femoral stems. We analyzed demographic data, proximal femur morphology, and the fracture type. Results: We identified 97 patients. Considering the proximal femur morphology, we found that there was statistically significant prevalence of Dorr A proximal femur morphology in the CLS® group and of Dorr C in the Alloclassic® group. Considering the distribution of the fracture pattern, we reported a non-statistically significant prevalence of the fracture pattern with stable stems in the CLS® group. Conclusions: The choice of the prosthetic design of the femoral stem is a crucial element when planning total hip arthroplasty. However, we found a non-statistically significant difference between the two stems considered, raising questions about the real role of stem design as a primary determinant of periprosthetic hip fractures.

16.
Article in English | MEDLINE | ID: mdl-38713877

ABSTRACT

PURPOSE: The purpose of this study was to compare micromotion of two new cementless tibial baseplates to a cementless design with well-published clinical success. METHODS: Three cementless tibial baseplate designs (fixed-bearing [FB] with keel and cruciform pegs, rotating-platform with porous central cone and pegs, FB with cruciform keel and scalloped pegs) were evaluated on sawbone models. Loading was applied to the baseplate at a rate of 1 Hz for 10,000 cycles, which represents 6-8 weeks of stair descent. This time frame also represents the approximate time length for the induction of biologic fixation of cementless implants. Compressive and shear micromotion at the sawbone-implant interface were measured. RESULTS: At the end of the loading protocol, the central cone rotating-platform design exhibited greater micromotion at the anterior (p < 0.001), posterior (p < 0.001) and medial locations (p = 0.049) compared to the other two implants. The central cone design also exhibited greater translational micromotion in the sagittal plane at the medial (p = 0.001) and lateral locations (p = 0.034) and in the coronal plane anteriorly (p = 0.007). CONCLUSION: The cementless central cone rotating-platform baseplate demonstrated greater vertical and translational micromotion compared to the two FB baseplates with a keel underloading. This may indicate lower initial mechanical stability in implants without a keel, which possibly affects osseointegration. The implication of this is yet unknown and requires further long-term clinical follow-up to correlate these laboratory findings. LEVEL OF EVIDENCE: V (biomechanical study).

17.
J Orthop Surg Res ; 19(1): 295, 2024 May 15.
Article in English | MEDLINE | ID: mdl-38750567

ABSTRACT

INTRODUCTION: Hip arthroplasty is a common orthopaedic procedure worldwide. There is an ongoing debate related to the fixation and anaesthesia impact on the 30-day mortality, particularly in the aging population with higher American Society of Anaesthesiology (ASA) Physical-Status. AIM: To study the 30-day all-cause mortality in patients undergoing primary hip arthroplasty, with regards to the impact of age, ASA-class, anaesthesia techniques, indication for surgery and fixation techniques. MATERIALS AND METHODS: Perioperative data for primary hip arthroplasty procedures for osteoarthritis and hip fractures registered in the Swedish Perioperative Registry (SPOR) between 2013 and June 2022 were collected. Binary logistic regressions were performed to assess the impact of age, ASA-class, anaesthetic technique, indication for surgery and fixation on odds ratio for 30-day mortality in Sweden. RESULTS: In total, 79,114 patients, 49,565 with osteoarthritis and 29,549 with hip fractures were included in the main study cohort. Mortality was significantly higher among hip fracture patients compared with osteoarthritis, cumulative 8.2% versus 0.1% at 30-days respectively (p < 0.001). Age above 80 years (OR3.7), ASA 3-5 (OR3.3) and surgery for hip fracture (OR 21.5) were associated with significantly higher odds ratio, while hybrid fixation was associated with a significantly lower odds ratio (OR0.4) of 30-day mortality. In the same model, for the subgroups of osteoarthritis and hip fracture, only age (OR 3.7) and ASA-class (OR 3.3) had significant impact, increasing the odds ratio for 30-day mortality. Hemi arthroplasty was commonly used among the hip fracture patients 20.453 (69.2%), and associated with a significantly higher odds ratio for all-cause 30-day mortality as compared to total hip arthroplasty when adjusting for age and ASA-class and fixation 2.3 (95%CI 1.9-2.3, p < 0.001). CONCLUSIONS: All-cause 30-day mortality associated with arthroplasty differed significantly between the two cohorts, hip fracture, and osteoarthritis (8.2% and 0.1% respectively) and mortality expectedly increased with age and higher ASA-class. Anaesthetic method and cement-fixation did not impact the odds ratio for all-cause 30-day mortality after adjustment for age and ASA-class.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Fractures , Osteoarthritis, Hip , Registries , Humans , Arthroplasty, Replacement, Hip/mortality , Sweden/epidemiology , Aged , Female , Male , Aged, 80 and over , Hip Fractures/surgery , Hip Fractures/mortality , Osteoarthritis, Hip/surgery , Osteoarthritis, Hip/mortality , Middle Aged , Age Factors , Cohort Studies , Time Factors
18.
Article in English | MEDLINE | ID: mdl-38695885

ABSTRACT

PURPOSE: According to Vancouver classification, B2 type fractures are most often treated with removal of the loose stem and implantation of a long stem that bypasses the fracture site. However, there is a controversy about the stem fixation that should be used: cemented or cementless. Hence, this study aims to compare cemented and cementless stems in prosthetic revision due to Vancouver B2 (VB2) periprosthetic hip fracture. METHODS: A retrospective study was done including all the patients treated with stem exchange due to VB2 periprosthetic hip fracture in a tertiary hospital between 2015 and 2022. Patients were divided into two groups according to the stem fixation used: cemented or cementless. Functional outcomes, hospital stay, surgical time, complication rate, and mortality were compared between the two groups of patients. RESULTS: Of the 30 included patients, 13 (43.4%) were treated with cementless stems and 17 (56.7%) with cemented stems. There were no statistically significant differences in age, gender, anesthesia risk scale (ASA) or functional capacity prior to the intervention. Patients treated with cementless stems had a higher complication and reintervention rate than those treated with cemented stems: 62 and 45% versus 34 and 6% (p = 0.035; p = 0.010), respectively. Furthermore, in the group of cementless stems a higher proportion of non-union was found (53.8% vs. 17.6%; p = 0.037). Also, the hospital stay (33 vs. 24 days; p = 0.037) and the time to full weight-bearing (21 days vs. 9 days; p < 0.001) were longer in the cementless stem group. CONCLUSION: Cemented fixation in stem revision due to Vancouver B2 periprosthetic hip fracture could be an optimal option with faster recovery which could decrease the rate of complications and reintervention, without compromising the fracture healing and patient mortality. Thus, this option can be considered when an anatomical reduction can be obtained, especially in elderly patients with multiple comorbidities in which a less aggressive surgical option should be considered.

19.
Hip Int ; : 11207000241249673, 2024 May 03.
Article in English | MEDLINE | ID: mdl-38700947

ABSTRACT

The optimal fixation method in total hip arthroplasty (THA) remains controversial. Initial concerns related to the long-term performance of cement fixation as well as cement disease led to the development of cementless implants, and registry data has indicated that the use of this type of fixation has increased in recent years. However, data from these same registries has not shown any improvement in outcomes when compared to cement fixation. On the contrary, while similar outcomes are seen when comparing these fixation types in younger patients (<70 years of age), cementless fixation has shown increased implant failure and revision rates in elderly patients (>70 years of age). Given the increased projected volume of THA in the United States over the next decade, it is important to utilise available data to make clinical decisions that minimise not only individual patient harm, but also the burden on the healthcare system itself. This review provides an overview of currently available outcomes data comparing cement and cementless fixation, as well as an updated analysis of current trends in fixation use in THA. We furthermore provide a comprehensive technique guide to help surgeons optimise cement fixation of the femoral component for THA and hemiarthroplasty.

20.
J Arthroplasty ; 2024 May 11.
Article in English | MEDLINE | ID: mdl-38735547

ABSTRACT

BACKGROUND: Periprosthetic femoral fractures (PFFs) are serious complications in hip arthroplasty for femoral neck fractures. The rates of intraoperative (iPFFs) and postoperative PFFs (pPFFs) are higher in cementless stem cases than in cemented cases. This study aimed to investigate the effects of cerclage cabling on PFF prevention in cementless arthroplasty for femoral neck fractures. METHODS: This retrospective study included 329 consecutive patients who underwent hip arthroplasty using a cementless stem for femoral neck fractures. A total of 159 and 170 patients were in the non-cabling and cabling groups, respectively. Patient characteristics were comparable in both groups. The PFF occurrence (iPFF and pPFF) rates, reoperation rates, operative time, and blood loss volume were compared between the groups. RESULTS: The iPFF rate was significantly higher in the noncabling group (6.3%) than in the cabling group (0%, P < .001). The rate of pPFF was significantly higher in the non-cabling group (5.1%) than in the cabling group (0.6%; P = .016). All patients in the non-cabling group required reoperation (5.1%), whereas the patient in the cabling group was an ambulatory case and required no reoperation (0%, P = .003). No significant difference in either operative time or blood loss volume was observed between the non-cabling (50 minutes, 133 mL) and cabling (52 minutes, P = .244; 149 mL, P = .212, respectively) groups. CONCLUSIONS: When a cementless stem is used to treat unstable femoral neck fractures, cerclage cabling effectively prevents iPPF and pPPF without increasing surgical time or blood loss volume.

SELECTION OF CITATIONS
SEARCH DETAIL
...