Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 4.176
Filter
1.
J Med Imaging (Bellingham) ; 12(Suppl 1): S13002, 2025 Jan.
Article in English | MEDLINE | ID: mdl-39055550

ABSTRACT

Purpose: Accurate detection of microcalcifications ( µ Calcs ) is crucial for the early detection of breast cancer. Some clinical studies have indicated that digital breast tomosynthesis (DBT) systems with a wide angular range have inferior µ Calc detectability compared with those with a narrow angular range. This study aims to (1) provide guidance for optimizing wide-angle (WA) DBT for improving µ Calcs detectability and (2) prioritize key optimization factors. Approach: An in-silico DBT pipeline was constructed to evaluate µ Calc detectability of a WA DBT system under various imaging conditions: focal spot motion (FSM), angular dose distribution (ADS), detector pixel pitch, and detector electronic noise (EN). Images were simulated using a digital anthropomorphic breast phantom inserted with 120 µ m µ Calc clusters. Evaluation metrics included the signal-to-noise ratio (SNR) of the filtered channel observer and the area under the receiver operator curve (AUC) of multiple-reader multiple-case analysis. Results: Results showed that FSM degraded µ Calcs sharpness and decreased the SNR and AUC by 5.2% and 1.8%, respectively. Non-uniform ADS increased the SNR by 62.8% and the AUC by 10.2% for filtered backprojection reconstruction with a typical clinical filter setting. When EN decreased from 2000 to 200 electrons, the SNR and AUC increased by 21.6% and 5.0%, respectively. Decreasing the detector pixel pitch from 85 to 50 µ m improved the SNR and AUC by 55.6% and 7.5%, respectively. The combined improvement of a 50 µ m pixel pitch and EN200 was 89.2% in the SNR and 12.8% in the AUC. Conclusions: Based on the magnitude of impact, the priority for enhancing µ Calc detectability in WA DBT is as follows: (1) utilizing detectors with a small pixel pitch and low EN level, (2) allocating a higher dose to central projections, and (3) reducing FSM. The results from this study can potentially provide guidance for DBT system optimization in the future.

2.
Clin Imaging ; 113: 110235, 2024 Jul 20.
Article in English | MEDLINE | ID: mdl-39059085

ABSTRACT

OBJECTIVE: This study aims to assess the efficacy of polyenergetic reconstruction methods in reducing streak artifacts caused by dual source imaging in Photon Counting Detector Computed Tomography (PCD-CT) imaging, thereby improving image quality and diagnostic accuracy. METHODS: A retrospective cohort study was conducted, involving 50 patients who underwent chest Computed Tomography Angiography with PCD-CT, focusing on those with streak artifacts. Quantitative and qualitative analyses were performed on images reconstructed using monoenergetic and polyenergetic techniques. Quantitative evaluations measured the attenuation of tracheal air density in regions affected by streak artifacts, while qualitative assessments employed a modified Likert scale to rate image quality. Statistical analyses included Wilcoxon's signed-rank tests and Spearman's correlation, alongside assessments of inter-rater reliability. RESULTS: There was significantly lower attenuation of tracheal air density on the polyenergetic reconstructions (Median - 1010 ± 62 HU vs -930 ± 110 HU; P < 0.001), and significantly decreased variation on the polyenergetic reconstructions (Median 65.2 ± 79.5 HU vs 38.8 ± 33.9 HU; P < 0.001). The median modified-Likert scale were significantly better for the polyenergetic reconstructions (median modified-Likert 4 ± 0.5 vs 2.5 ± 1; P < 0.001). The inter-rater agreement was substantial and not significantly different between reconstructions (Gwet's ACPolyenergetic = 0.78 vs Gwet's ACVMI = 0.775). CONCLUSION: Polyenergetic reconstruction significantly mitigates streak artifacts in PCD-CT imaging, enhancing quantitative and qualitative image quality. This advancement addresses a known limitation of current PCD-CT reconstruction techniques, offering a promising approach to improving diagnostic reliability and accuracy in clinical practice. We demonstrate that future software implementations can resolve this artifact.

3.
Appl Radiat Isot ; 212: 111452, 2024 Jul 20.
Article in English | MEDLINE | ID: mdl-39059115

ABSTRACT

A highly segmented High-Purity Germanium (HPGe) detector was used to measure 241Am activity located inside the lungs of an anthropomorphic phantom with various active and passive shield configurations. It was found that the background suppression shield does not play a significant role in reducing the Minimum Detectable Activity (MDA) after veto, based on the segmentation in the depth direction of the HPGe, when measuring low-energy gamma rays. A reduction of up to 57% in the MDA was achieved. The MDA could be further improved by a thinner lateral segmentation and an optimized anti-Compton shield coupled with an active or passive backplate. The new detector application would be particularly useful in mobile whole-body counting units, where the natural background radiation poses a challenge when measuring low-energy gamma rays.

4.
Phys Med Biol ; 2024 Jul 26.
Article in English | MEDLINE | ID: mdl-39059440

ABSTRACT

OBJECTIVE: High-resolution PET relies on the accurate positioning of annihilation photons impinging the crystal array. However, conventional positioning algorithms in light-sharing PET detectors are often limited due to edge effects and/or the absence of additional information for identifying and correcting scattering within the crystal array (known as inter-crystal scattering). Using GATE simulations, this study explores the feasibility of deep neural network techniques for more precise event positioning in finely segmented and highly multiplexed PET detectors with light-sharing. Approach: Initially, the spatial and statistical properties of inter-crystal scatter (ICS) events in finely segmented LYSO PET detectors were investigated. Next, a deep neural network (DNN) for crystal localisation was designed, trained and tested with light distributions of photoelectric (P) and Compton + photoelectric (CP) events simulated using optical GATE and an analytical method to speed up data generation. Using the statistical properties of ICS events, an energy-guided positioning algorithm was then built into the DNN. The positioning algorithm enables selection of the unique or first crystal of interaction in P and CP events, respectively. Performance of the DNN was compared with Anger logic using light distributions from simulated 511-keV point sources placed at different locations around a single PET detector module. Main results: The fraction of events forward and backward scattered in the LYSO detector was 0.54 and 0.46, respectively, whereas naïve application of the Klein-Nishina formulation predicts 70% forward scatter. Despite coarse photodetector data due to signal multiplexing, the DNN demonstrated a crystal classification accuracy of 90% for P events and 82% for CP events. For crystal positioning, the DNN outperformed Anger logic by at least 34% and 14% for P and CP events, respectively. Further improvement is somewhat constrained by the physics - specifically, the ratio of backward to forward scattering of gamma rays within the crystal array being close to 1. This prevents selecting the first crystal of interaction in CP events with a high degree of certainty. Significance: Light sharing and multiplexed PET detectors are common in high-resolution PET, yet their traditional positioning algorithms often underperform due to edge effects and/or the difficulty in correcting ICS events. Our study indicates that energy-guided DNN-based event positioning has the potential to enhance 2D coincidence event positioning accuracy by nearly a factor of 3 compared to Anger logic. However, further improvements are difficult to foresee without additional information such as event timing.

5.
Tomography ; 10(7): 1168-1191, 2024 Jul 22.
Article in English | MEDLINE | ID: mdl-39058061

ABSTRACT

Spectral photon-counting cone-beam computed tomography (CT) imaging is challenged by individual pixel response behaviours, which lead to noisy projection images and subsequent image artefacts like rings. Existing methods to correct for this either use calibration measurements, like signal-to-thickness calibration (STC), or perform a post-processing ring artefact correction of sinogram data or scan reconstructions without taking the pixel response explicitly into account. Here, we present a novel post-processing method (digital-to-analogue converter (DAC)-shifting) which explicitly measures the current pixel response using flat-field images and subsequently corrects the projection data. The DAC-shifting method was evaluated using a repeat series of the spectral photon-counting imaging (Medipix3) of a phantom with different density inserts and iodine K-edge imaging. The method was also compared against polymethyl methacrylate (PMMA)-based STC. The DAC-shifting method was shown to be effective in correcting individual pixel responses and was robust against detector instability; it led to a 47.4% average reduction in CT-number variation in homogeneous materials, with a range of 40.7-55.6%. On the contrary, the STC correction showed varying results; a 13.7% average reduction in CT-number variation, ranging from a 43.7% increase to a 45.5% reduction. In K-edge imaging, DAC-shifting provides a sharper attenuation peak and more uniform CT values, which are expected to benefit iodine concentration quantifications.


Subject(s)
Artifacts , Phantoms, Imaging , Photons , Cone-Beam Computed Tomography/methods , Reproducibility of Results , Humans , Image Processing, Computer-Assisted/methods , Calibration , Algorithms , Polymethyl Methacrylate , Tomography, X-Ray Computed/methods
6.
Diagnostics (Basel) ; 14(14)2024 Jul 15.
Article in English | MEDLINE | ID: mdl-39061660

ABSTRACT

OBJECTIVES: Diagnostic reference levels (DRLs) are crucial tools for optimizing radiation exposure during different radiological examinations. This study aimed to establish preliminary DRLs for commonly performed computed tomographic angiography (CTA) examinations in Saudi Arabia. METHODS: Data for three types of CTA examinations (cerebral, pulmonary, and lower-extremity) were collected from six medical cities across Saudi Arabia. Data sets related to 723 CTAs with a mean patient weight of 75 kg were analysed in detail. The DRL values were determined based on the 75th, median, and 25th CT dose index volume (CTDIvol) and dose length product (DLP) values. RESULTS: The established DRLs were 1221 mGy cm for cerebral CTAs, 475 mGy cm for pulmonary CTAs, and 1040 mGy cm for lower-extremity CTAs. These values were comparable to those reported in other studies. CONCLUSIONS: This study provides preliminary DRLs for three common CTA procedures in Saudi Arabia. The widespread implementation of a low kVp and a high level of image reconstruction (IR) presents an opportunity for further dose reduction. These findings can serve as a foundation for future nationwide DRL surveys and the optimization of CTA imaging protocols in Saudi Arabia.

7.
J Environ Manage ; 366: 121918, 2024 Jul 20.
Article in English | MEDLINE | ID: mdl-39033624

ABSTRACT

Improving water quality to provide freshwater is an urgent requirement for regional and even global social development. More accurate simulation of non-point sources pollution, monitored mainly by total nitrogen (TN) and total phosphorus (TP), has always been a challenge for InVEST water purification model, particularly in agricultural areas. This can be attributed to the fact that there is no reference data for TN and TP to rectify the outcomes modelled by this model. This paper provided these data to rectify simulation results of TN and TP to ensure their accuracy. The Huai River watershed (HRW) is an important grain production area with slow economic development, and non-point source pollution has exceeded point-source pollution. There is an urgent need for water management authorities to obtain complete spatio-temporal data on TN and TP loads and their exports to improve water quality. The reference data onloads and exports of TN and TP were estimated for the entire watershed and its sub-watersheds through an investigation-evaluation technique during 1980-2018. TN and TP loads generated from the agricultural sector were the major pollution sources in the HRW and had similar time trends during the same period. The spatial distribution of TN and TP exports was modelled byusingthe InVEST water purification model, and it was found that the temporal trends for the final exports of TN and TP into river systems were similar to those for TN and TP loads in the HRW for 1980-2018. Key driving factors were detected using the Geo-detector method to quantify the contribution rates of factors to the spatiotemporal exports of TN and TP. Our results showed that individual factors, such as precipitation and land use/cover, were the most important factors driving spatio-temporal variations in TN and TP exports in the HRW from 1980 to 2018. Meanwhile, the contribution rates of interactions between land use/cover and other factors were consistently highest in this watershed during the same period. In this study, we estimated the loads and exports of TN and TP, and modelled their spatial patterns in this watershed from 1980 to 2018, providing important information on TN and TP for water-related management authorities. We also provide a method for other river systems to calibrate the parameters in the biophysical table of InVEST water purification model based on final exports of TN and TP.

8.
Quant Imaging Med Surg ; 14(7): 4376-4387, 2024 Jul 01.
Article in English | MEDLINE | ID: mdl-39022223

ABSTRACT

Background: There is no unified scope for regional lymph node (LN) dissection in patients with pancreatic ductal adenocarcinoma (PDAC). Incomplete regional LN dissection can lead to postoperative recurrence, while blind expansion of the scope of regional LN dissection significantly increases the perioperative risk without significantly prolonging overall survival. We aimed to establish a noninvasive visualization tool based on dual-layer detector spectral computed tomography (DLCT) to predict the probability of regional LN metastasis in patients with PDAC. Methods: A total of 163 regional LNs were reviewed and divided into a metastatic cohort (n=58 LNs) and nonmetastatic cohort (n=105 LNs). The DLCT quantitative parameters and the nodal ratio of the longest axis to the shortest axis (L/S) of the regional LNs were compared between the two cohorts. The DLCT quantitative parameters included the iodine concentration in the arterial phase (APIC), normalized iodine concentration in the arterial phase (APNIC), effective atomic number in the arterial phase (APZeff), normalized effective atomic number in the arterial phase (APNZeff), slope of the spectral attenuation curves in the arterial phase (APλHU), iodine concentration in the portal venous phase (PVPIC), normalized iodine concentration in the portal venous phase (PVPNIC), effective atomic number in the portal venous phase (PVPZeff), normalized effective atomic number in the portal venous phase (PVPNZeff), and slope of the spectral attenuation curves in the portal venous phase (PVPλHU). Logistic regression analysis based on area under the curve (AUC) was used to analyze the diagnostic performance of significant DLCT quantitative parameters, L/S, and the models combining significant DLCT quantitative parameters and L/S. A nomogram based on the models with highest diagnostic performance was developed as a predictor. The goodness of fit and clinical applicability of the nomogram were assessed through calibration curve and decision curve analysis (DCA). Results: The combined model of APNIC + L/S (APNIC + L/S) had the highest diagnostic performance among all models, yielding an AUC, sensitivity, and specificity of 0.878 [95% confidence interval (CI): 0.825-0.931], 0.707, and 0.886, respectively. The calibration curve indicated that the APNIC-L/S nomogram had good agreement between the predicted probability and the actual probability. Meanwhile, the decision curve indicated that the APNIC-L/S nomogram could produce a greater net benefit than could the all- or-no-intervention strategy, with threshold probabilities ranging from 0.0 to 0.75. Conclusions: As a valid and visual noninvasive prediction tool, the APNIC-L/S nomogram demonstrated favorable predictive efficacy for identifying metastatic LNs in patients with PDAC.

9.
Nanotechnology ; 35(40)2024 Jul 22.
Article in English | MEDLINE | ID: mdl-38991504

ABSTRACT

Although the photoresponse cut-off wavelength of Si is about 1100 nm due to the Si bandgap energy, the internal photoemission effect (IPE) of the Au/Si junction in Schottky detector can extend the absorption wavelength, which makes it a promising candidate for the Si-based infrared detector. However, due to low light absorption, low photon-electron interaction, and poor electron injection efficiency, the near-infrared light detection efficiency of the Schottky detector is still insufficient. The synergistic effect of Si nano/microstructures with a strong light trapping effect and nanoscale Au films with surface plasmon enhanced absorption may provide an effective solution for improving the detection efficiency. In this paper, a large-area periodic Si microcone array covered by an Au film has successfully been fabricated by one-time dry etching based on the mature polystyrene microspheres lithography technique and vacuum thermal deposition, and its properties for hot electron-based near infrared photodetection are investigated. Optical measurements show that the 20 nm-thick Au covered Si microcone array exhibits a low reflectance and a strong absorption (about 85%) in wide wavelength range (900-2500 nm), and the detection responsivity can reach a value as high as 17.1 and 7.0 mA W-1at 1200 and 1310 nm under the front illumination, and 35.9 mA W-1at 1310 nm under the back illumination respectively. Three-dimensional finite difference time domain (3D-FDTD) simulation results show that the enhanced local electric field in the Au layer distributes near the air/Au interface under the front illumination and close to the Au/Si interface under the back illumination. The back illumination favors the injection of photo-generated hot electrons in Au layer into Si, which can explain the higher responsivity under the back illumination. Our research is expected to promote the practical application of Schottky photodetectors to Si-compatible near infrared photodetectors.

10.
J Appl Clin Med Phys ; : e14476, 2024 Jul 19.
Article in English | MEDLINE | ID: mdl-39031856

ABSTRACT

OBJECTIVE: An accurate measurement of x-ray beams is expected to reduce the uncertainties associated with estimating radiation risk to patients in clinical settings. To perform assessment tasks based on the readings of a solid-state detector (SSD) using semiconductor technology, the characteristics of the detector should be elucidated. In this study, we evaluated the measurement accuracy of a new SSD under diagnostic x-ray beam conditions in terms of air kerma, tube voltage, and half-value layer (HVL). The performance of the SSD was then compared with those of reference instruments. METHODS: The tube voltage was varied within the range of 50-120 kV in steps of 10 kV and the thickness and materials of additional filters were concurrently changed (several combinations were tested). In addition, the dose rate and energy dependence of the SSD were also investigated. These effects were analyzed based on statistical significance tests. Furthermore, the expanded uncertainties in the series of measurements were meticulously calculated. RESULTS: The results showed average relative differences of -3.26 ± 1.33%, 0.44 ± 1.01%, and -2.60 ± 3.31% for air kerma, tube voltage, and HVL, respectively. Furthermore, air kerma did not exhibit any dependence on dose rate and energy, in contrast to tube voltage and HVL measurements. CONCLUSION: The measurement values of the SSD fall within the acceptable range of uncertainty, highlighting its measurement accuracy and reliability. Furthermore, based on the characteristics elucidated by this study, valuable insights are provided concerning the assurance of appropriate measurement values in clinical settings.

11.
J Chromatogr A ; 1731: 465175, 2024 Jul 19.
Article in English | MEDLINE | ID: mdl-39032217

ABSTRACT

In recent years, miniaturized analytical instruments have been developing to meet the needs of portable and rapid analysis. The key of miniaturized analytical equipment is the miniaturization and integration of functional modules. This paper aims to develop a miniaturized photometric detector and separation microfluidic chip for a liquid chromatography (LC) system. The detector uses a light-emitting diode to emit ultraviolet light, which is collimated by an internal double lens. A Z-shaped flow cell with a long optical path is designed and fabricated in the separation microfluidic chip with a three-layer structure, which provides a tubing-free connection between the separation and detection unit. Detector performance is evaluated using hemoglobin (Hb) samples, with an upper limit of detection linearity (95 %) of 0.345 AU and stray light level as low as 0.08 %. Additionally, the microchip channel can be filled with cation exchange resin and C18 particles. Finally, an ion LC system and a reversed-phase LC system were constructed based on the miniaturized photometric detector and two microchips with different packed columns, respectively, and were successfully used in the separation and detection of two metabolic markers (glycated hemoglobin or bilirubin). The results of this study are expected to facilitate the development of a portable LC system and their application in community health services and family health management of chronic diseases.

12.
J Dent (Shiraz) ; 25(2): 138-146, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38962073

ABSTRACT

Statement of the Problem: It is essential to address caries risk at an early stage for the prevention of dental caries. Mobile application CaRisk is designed in a particular way to self-assess the dental caries risk by the individual's themselves. Purpose: The current study aimed to assess the dental caries risk among age groups 5-6 and 35-44 using self-assessment caries risk mobile application CaRisk and compare it with the deft and DMFT values. Materials and Method: This cross-sectional study was conducted in Chennai, India; to evaluate the risk of dental caries in children aged 5 to 6 and adults aged 35 to 44. The scores of the mobile application CaRisk and the decayed- extracted- filled teeth (deft)/ decayed-missing-filled-teeth (DMFT) caries risk assessment were evaluated. Descriptive statistics were performed. The risk category was determined by frequency. Chi-square analysis was done to determine whether the DMFT scores and the CaRisk mobile app were associated. The correlation was performed between the CaRisk mobile application and DMFT scores. Results: Association was found between the caries risk assessment score of the mobile application CaRisk and the DMFT and deft scores of the adults and children for both the age groups 5-6 and 35-44 years respectively and it indicates that it was found to be statistically significant. Pearson's correlation was performed to assess the strength of association and R-values obtained for the age group 5-6 and 35-44 years respectively, which was statistically significant (0.892 and 0.840). Conclusion: This CaRisk mobile application scores correlate with the deft and DMFT scores and it is an effective self-diagnosis tool for assessing dental caries risk assessment. Further, it is suggested that the mobile application CaRisk should be tested among a huge population.

13.
Article in English | MEDLINE | ID: mdl-39005115

ABSTRACT

The atomic pair distribution function (PDF) is a real-space representation of the structure of a material. Experimental PDFs are obtained using a Fourier transform from total scattering data which may or may not have Bragg diffraction peaks. The determination of Bragg peak resolution in scattering data from the fundamental physical parameters of the diffractometer used is well established, but after the Fourier transform from reciprocal to direct space, these contributions are harder to identify. Starting from an existing definition of the resolution function of large-area detectors for X-ray diffraction, this approach is expanded into direct space. The effect of instrumental parameters on PDF peak resolution is developed mathematically, then studied with modelling and comparison with experimental PDFs of LaB6 from measurements made in different-sized capillaries.

14.
Sensors (Basel) ; 24(13)2024 Jun 26.
Article in English | MEDLINE | ID: mdl-39000924

ABSTRACT

Increasing concerns about air quality due to fossil fuel combustion, especially nitrogen oxides (NOx) from marine and diesel engines, necessitate advanced monitoring systems due to the significant health and environmental impacts of nitrogen dioxide (NO2). In this study, a gas detection system based on the principle of the non-dispersive infrared (NDIR) technique is proposed. Firstly, the pyroelectric detector was developed by employing an ultra-thin LiTaO3 (LT) layer as the sensitive element, integrated with nanoscale carbon material prepared by wafer-level graphics technology as the infrared absorption layer. Then, the sensor was hermetically sealed using inert gas through energy storage welding technology, exhibiting a high detectivity (D*) value of 4.19 × 108 cm·âˆšHz/W. Subsequently, a NO2 gas sensor was engineered based on the NDIR principle employing a Micro Electro Mechanical System (MEMS) infrared (IR) emitter, featuring a light path chamber length of 1.5 m, along with integrated signal processing and software calibration algorithms. This gas sensor was capable of detecting NO2 concentrations within the range of 0-500 ppm. Initial tests indicated that the gas sensor exhibited a full-scale relative error of less than 0.46%, a limit of 2.8 ppm, a linearity of -1.09%, a repeatability of 0.47% at a concentration of 500 ppm, and a stability of 2% at a concentration of 500 ppm. The developed gas sensor demonstrated significant potential for application in areas such as industrial monitoring and analytical instrumentation.

15.
Sensors (Basel) ; 24(13)2024 Jul 05.
Article in English | MEDLINE | ID: mdl-39001160

ABSTRACT

As the weak link in electro-optical imaging systems, photodetectors have always faced the threat of laser damage. In this paper, we experimentally investigated the damage mechanism of the photodetector induced by the out-of-band laser. The damage thresholds of the mid-infrared pulsed laser for Charge Coupled Device (CCD) and HgCdTe detectors were determined through damage experiments. The analysis of the damage phenomena and data for both CCD and HgCdTe detectors clearly demonstrated that out-of-band mid-infrared pulsed lasers could entirely incapacitate CCD and HgCdTe detectors. Our analysis of the damage process and data revealed that the primary mechanism of damage to CCD and HgCdTe detectors by mid-infrared pulsed lasers was primarily thermal. This study serves as a reference for further research on the mid-infrared pulsed laser damage mechanisms of CCD and HgCdTe detectors, as well as for laser protection and performance optimization in imaging systems.

16.
J Environ Radioact ; 278: 107491, 2024 Jul 13.
Article in English | MEDLINE | ID: mdl-39003964

ABSTRACT

An advanced spatial-unfolding technique capable of reconstructing the activity distribution within an exclusion zone from Compton gamma imager measurements taken outside of it is introduced. Although the method is generally applicable to extended sources, we demonstrate it here on a calibrated Cs-137 point source through Monte Carlo simulation studies as well as with measurements made using a Silicon Compton Telescope for Safety and Security (SCoTSS) gamma imager. For synthetic data the method accurately reconstructs the total activity contained within the mapped zone of interest, even when the size of the basis elements used to reconstruct the activity distribution is larger than the source itself. For experimental data, the method reliably located the source but underestimated its activity by up to 17%. This is accurate enough for real-world security applications. The underestimation is likely due to effects not yet included in the simulated response of the detector. The method has widespread applicability in the radiological/nuclear safety and security field, particularly for scenarios in which a threat material or contaminated area lies within a no-entry or no-fly zone.

17.
Ann Biomed Eng ; 2024 Jul 16.
Article in English | MEDLINE | ID: mdl-39012563

ABSTRACT

The ability of articular cartilage to withstand significant mechanical stresses during activities, such as walking or running, relies on its distinctive structure. Integrating detailed tissue properties into subject-specific biomechanical models is challenging due to the complexity of analyzing these characteristics. This limitation compromises the accuracy of models in replicating cartilage function and impacts predictive capabilities. To address this, methods revealing cartilage function at the constituent-specific level are essential. In this study, we demonstrated that computational modeling derived individual constituent-specific biomechanical properties could be predicted by a novel nanoparticle contrast-enhanced computer tomography (CECT) method. We imaged articular cartilage samples collected from the equine stifle joint (n = 60) using contrast-enhanced micro-computed tomography (µCECT) to determine contrast agents' intake within the samples, and compared those to cartilage functional properties, derived from a fibril-reinforced poroelastic finite element model. Two distinct imaging techniques were investigated: conventional energy-integrating µCECT employing a cationic tantalum oxide nanoparticle (Ta2O5-cNP) contrast agent and novel photon-counting µCECT utilizing a dual-contrast agent, comprising Ta2O5-cNP and neutral iodixanol. The results demonstrate the capacity to evaluate fibrillar and non-fibrillar functionality of cartilage, along with permeability-affected fluid flow in cartilage. This finding indicates the feasibility of incorporating these specific functional properties into biomechanical computational models, holding potential for personalized approaches to cartilage diagnostics and treatment.

18.
Adv Mater ; : e2406193, 2024 Jul 14.
Article in English | MEDLINE | ID: mdl-39003617

ABSTRACT

Methylammonium lead tribromide (MAPbBr3) stands out as the most easily grown wide-band-gap metal halide perovskite. It is a promising semiconductor for room-temperature gamma-ray (γ-ray) spectroscopic detectors, but no operational devices are realized. This can be largely attributed to a lack of understanding of point defects and their influence on detector performance. Here, through a combination of crystal growth design and defect characterization, including positron annihilation and impedance spectroscopy, the presence of specific point defects are identified and correlated to detector performance. Methylammonium (MA) vacancies, MA interstitials, and Pb vacancies are identified as the dominant charge-trapping defects in MAPbBr3 crystals, while Br vacancies caused doping. The addition of excess MABr reduces the MA and Br defects and so enables the detection of energy-resolved γ-ray spectra using a MAPbBr3 single-crystal device. Interestingly, the addition of formamidinium (FA) cations, which converted to methylformamidinium (MFA) cations by reaction with MA+ during crystal growth further reduced MA defects. This enabled an energy resolution of 3.9% for the 662 keV 137Cs line using a low bias of 100 V. The work provides direction toward enabling further improvements in wide-bandgap perovskite-based device performance by reducing detrimental defects.

19.
Acad Radiol ; 2024 Jul 04.
Article in English | MEDLINE | ID: mdl-38969575

ABSTRACT

RATIONALE AND OBJECTIVES: To assess image quality and radiation dose of ultra-high-pitch CT pulmonary angiography (CTPA) with free-breathing technique for diagnosis of pulmonary embolism using a photon-counting detector (PCD) CT compared to matched energy-integrating detector (EID)-based single-energy CTPA. MATERIALS AND METHODS: Fifty-one PCD-CTPAs were prospectively compared to 51 CTPAs on a third-generation dual-source EID-CT. CTPAs were acquired with an ultra-high-pitch protocol with free-breathing technique (40 mL contrast medium, pitch 3.2) at 140 kV (PCD) and 70-100 kV (EID). Iodine maps were reconstructed from spectral PCD-CTPAs. Image quality of CTPAs and iodine maps was assessed independently by three radiologists. Additionally, CT attenuation numbers within pulmonary arteries as well as signal-to-noise and contrast-to-noise ratios (SNR, CNR) were compared. Administered radiation dose was compared. RESULTS: CT attenuation was higher in the PCD-group (all P < 0.05). CNR and SNR were higher in lobar pulmonary arteries in PCD-CTPAs (P < 0.05), whereas no difference was ascertained within the pulmonary trunk (P > 0.05). Image quality of PCD-CTPA was rated best by all readers (excellent/good image quality in 96.1% of PCD-CTPAs vs. 50.9% of EID-CTPAs). PCD-CT produced no non-diagnostic scans vs. three non-diagnostic (5.9%) EID-CTPAs. Radiation dose was lower with PCD-CT than with EID-CT (effective dose 1.33 ± 0.47 vs. 1.80 ± 0.82 mSv; all P < 0.05). CONCLUSION: Ultra-high-pitch CTPA with free-breathing technique with PCD-CT allows for superior image quality with significantly reduced radiation dose and full spectral information. With the ultra-high pitch, only PCD-CTPA enables reconstruction of iodine maps containing additional functional information.

20.
Materials (Basel) ; 17(13)2024 Jul 01.
Article in English | MEDLINE | ID: mdl-38998311

ABSTRACT

Sn-doped Ga2O3 thin films and metal-semiconductor-metal (MSM) ultraviolet detectors were prepared using the co-sputtering method to enhance their photoelectric performance. The results revealed that Sn doping can effectively change the optical and electrical properties of thin films, greatly improving the photoelectric responsiveness of the devices. Through microstructure testing results, all of the thin film structures were determined to be monoclinic beta phase gallium oxide. At a DC power of 30 W, the thickness of the Sn-doped thin film was 430 nm, the surface roughness of the thin film was 4.94 nm, and the carrier concentration, resistivity, and mobility reached 9.72 × 1018 cm-3, 1.60 × 10-4 Ω·cm, and 45.05 cm3/Vs, respectively. The optical results show that Sn doping clearly decreases the transmission of thin films and that the bandgap can decrease to 3.91 eV. Under 30 W DC power, the photo dark current ratio of the detector can reach 101, time responses of tr = 31 s and tf = 22.83 s were obtained, and the spectral responsivity reached 19.25 A/W.

SELECTION OF CITATIONS
SEARCH DETAIL
...