1.
BMC Pulm Med ; 23(1): 406, 2023 Oct 26.
Article in English | MEDLINE | ID: mdl-37884922

ABSTRACT

BACKGROUND: Lung function analysis in Parkinson's disease (PD) is often difficult due to the demand for adequate forced expiratory maneuvers. Respiratory oscillometry exams require onlyquiet tidal breathing and provide a detailed analysis of respiratory mechanics. We hypothesized that oscillometry would simplify the diagnosis of respiratory abnormalitiesin PD and improve our knowledge about the pathophysiological changes in these patients. MATERIALS AND METHODS: This observational study includes 20 controls and 47 individuals with PD divided into three groups (Hoehn and Yahr Scale 1-1.5; H&Y scale 2-3 and PD smokers).The diagnostic accuracy was evaluated by investigating the area under the receiver operating characteristic curve (AUC). RESULTS: Initial stages are related to increased peripheral resistance (Rp; p = 0.001). In more advanced stages, a restrictive pattern is added, reflected by reductions in dynamic compliance (p < 0.05) and increase in resonance frequency (Fr; p < 0.001). Smoking PD patients presented increased Rp (p < 0.001) and Fr (p < 0.01). PD does not introduce changes in the central airways. Oscillometric changes were correlated with respiratory muscle weakness (R = 0.37, p = 0.02). Rp showed adequate accuracy in the detection of early respiratory abnormalities (AUC = 0.858), while in more advanced stages, Fr showed high diagnostic accuracy (AUC = 0.948). The best parameter to identify changes in smoking patients was Rp (AUC = 0.896). CONCLUSION: The initial stages of PD are related to a reduction in ventilation homogeneity associated with changes in peripheral airways. More advanced stages also include a restrictive ventilatory pattern. These changes were correlated with respiratory muscle weakness and were observed in mild and moderate stages of PD in smokers and non-smokers. Oscillometry may adequately identify respiratory changes in the early stages of PD and obtain high diagnostic accuracy in more advanced stages of the disease.


Subject(s)
Parkinson Disease , Respiration Disorders , Humans , Oscillometry , Parkinson Disease/complications , Parkinson Disease/diagnosis , Spirometry , Lung , Respiratory Mechanics
2.
Med Biol Eng Comput ; 60(7): 2001-2014, 2022 Jul.
Article in English | MEDLINE | ID: mdl-35538199

ABSTRACT

To evaluate the ability of tracheal sound analysis (TSA) to detect airflow obstruction, particularly in patients with acromegaly. A simulated analysis compared free airflow conditions with airflow through orifice plates 6, 8, 10 and 12 mm in diameter. Based on these results, TSA and spirometry examinations were performed on controls (n = 17) and patients with acromegaly (n = 17). The simulated study showed that airway obstruction and airflow values increased the values of power and a progressive displacement of the spectral distribution towards higher frequencies. In agreement with the simulation, airway obstruction in patients with acromegaly also resulted in increased values of power (p < 0.002) and displacement of the spectral distribution (p < 0.01). Significant associations were observed between the TSA parameters and the spirometry indices of obstruction (p < 0.02). In addition, the TSA parameters achieved adequate diagnostic accuracy (AUC ≥ 0.887). The present study provides evidence that TSA during resting breathing would provide adequate biomarkers of early upper airway changes in patients with acromegaly. TSA is carried out during spontaneous ventilation, requires little from the patient, and is fast and inexpensive. Taken together, these practical considerations and the results of the present study suggest that TSA may improve lung function tests for patients with acromegaly. Summary of the study, overall design flow and the main results obtained.


Subject(s)
Acromegaly , Airway Obstruction , Pulmonary Disease, Chronic Obstructive , Acromegaly/diagnosis , Airway Obstruction/diagnosis , Humans , Lung , Respiratory Function Tests , Spirometry
3.
Biomed Eng Online ; 20(1): 31, 2021 Mar 25.
Article in English | MEDLINE | ID: mdl-33766046

ABSTRACT

INTRODUCTION: The use of machine learning (ML) methods would improve the diagnosis of respiratory changes in systemic sclerosis (SSc). This paper evaluates the performance of several ML algorithms associated with the respiratory oscillometry analysis to aid in the diagnostic of respiratory changes in SSc. We also find out the best configuration for this task. METHODS: Oscillometric and spirometric exams were performed in 82 individuals, including controls (n = 30) and patients with systemic sclerosis with normal (n = 22) and abnormal (n = 30) spirometry. Multiple instance classifiers and different supervised machine learning techniques were investigated, including k-Nearest Neighbors (KNN), Random Forests (RF), AdaBoost with decision trees (ADAB), and Extreme Gradient Boosting (XGB). RESULTS AND DISCUSSION: The first experiment of this study showed that the best oscillometric parameter (BOP) was dynamic compliance, which provided moderate accuracy (AUC = 0.77) in the scenario control group versus patients with sclerosis and normal spirometry (CGvsPSNS). In the scenario control group versus patients with sclerosis and altered spirometry (CGvsPSAS), the BOP obtained high accuracy (AUC = 0.94). In the second experiment, the ML techniques were used. In CGvsPSNS, KNN achieved the best result (AUC = 0.90), significantly improving the accuracy in comparison with the BOP (p < 0.01), while in CGvsPSAS, RF obtained the best results (AUC = 0.97), also significantly improving the diagnostic accuracy (p < 0.05). In the third, fourth, fifth, and sixth experiments, different feature selection techniques allowed us to spot the best oscillometric parameters. They resulted in a small increase in diagnostic accuracy in CGvsPSNS (respectively, 0.87, 0.86, 0.82, and 0.84), while in the CGvsPSAS, the best classifier's performance remained the same (AUC = 0.97). CONCLUSIONS: Oscillometric principles combined with machine learning algorithms provide a new method for diagnosing respiratory changes in patients with systemic sclerosis. The present study's findings provide evidence that this combination may help in the early diagnosis of respiratory changes in these patients.


Subject(s)
Diagnosis, Computer-Assisted , Machine Learning , Oscillometry , Respiration Disorders/complications , Respiration Disorders/diagnosis , Scleroderma, Systemic/complications , Scleroderma, Systemic/diagnosis , Adolescent , Adult , Aged , Algorithms , Artificial Intelligence , Biometry , Computers , Female , Humans , Male , Middle Aged , Spirometry , Young Adult
4.
Int J Chron Obstruct Pulmon Dis ; 15: 3273-3289, 2020.
Article in English | MEDLINE | ID: mdl-33324050

ABSTRACT

Purpose: This research examines the emerging role of respiratory oscillometry associated with integer (InOr) and fractional order (FrOr) respiratory models in the context of groups of patients with increasing severity. The contributions to our understanding of the respiratory abnormalities along the course of increasing COPD severity and the diagnostic use of this method were also evaluated. Patients and Methods: Forty-five individuals with no history of smoking or pulmonary diseases (control group) and 141 individuals with diagnoses of COPD were studied, being classified into 45 mild, 42 moderate, 36 severe and 18 very severe cases. Results: This study has shown initially that the course of increasing COPD severity was adequately described by the model parameters. This resulted in significant and consistent correlations among these parameters and spirometric indexes. Additionally, this evaluation enhanced our understanding of the respiratory abnormalities in different COPD stages. The diagnostic accuracy analyses provided evidence that hysteresivity, obtained from FrOr modeling, allowed a highly accurate identification in patients with mild changes [area under the receiver operator characteristic curve (AUC)= 0.902]. Similar analyses in groups of moderate and severe patients showed that peripheral resistance, derived from InOr modeling, provided the most accurate parameter (AUC=0.898 and 0.998, respectively), while in very severe patients, traditional, InOr and FrOr parameters were able to reach high diagnostic accuracy (AUC>0.9). Conclusion: InOr and FrOr modeling improved our knowledge of the respiratory abnormalities along the course of increasing COPD severity. In addition, the present study provides evidence that these models may contribute in the diagnosis of COPD. Respiratory oscillometry exams require only tidal breathing and are easy to perform. Taken together, these practical considerations and the results of the present study suggest that respiratory oscillometry associated with InOr and FrOr models may help to improve lung function tests in COPD.


Subject(s)
Pulmonary Disease, Chronic Obstructive , Humans , Oscillometry , Pulmonary Disease, Chronic Obstructive/diagnosis , Respiration , Respiratory Function Tests , Respiratory Mechanics , Spirometry
5.
Biomed Eng Online ; 19(1): 93, 2020 Dec 09.
Article in English | MEDLINE | ID: mdl-33298072

ABSTRACT

BACKGROUND: Fractional-order (FrOr) models have a high potential to improve pulmonary science. These models could be useful for biomechanical studies and diagnostic purposes, offering accurate models with an improved ability to describe nature. This paper evaluates the performance of the Forced Oscillation (FO) associated with integer (InOr) and FrOr models in the analysis of respiratory alterations in work-related asthma (WRA). METHODS: Sixty-two individuals were evaluated: 31 healthy and 31 with WRA with mild obstruction. Patients were analyzed pre- and post-bronchodilation. The diagnostic accuracy was evaluated using the area under the receiver operating characteristic curve (AUC). To evaluate how well do the studied models correspond to observed data, we analyzed the mean square root of the sum (MSEt) and the relative distance (Rd) of the estimated model values to the measured resistance and reactance measured values. RESULTS AND DISCUSSION: Initially, the use of InOr and FrOr models increased our understanding of the WRA physiopathology, showing increased peripheral resistance, damping, and hysteresivity. The FrOr model (AUC = 0.970) outperformed standard FO (AUC = 0.929), as well as InOr modeling (AUC = 0.838) in the diagnosis of respiratory changes, achieving high accuracy. FrOr improved the curve fitting (MSEt = 0.156 ± 0.340; Rd = 3.026 ± 1.072) in comparison with the InOr model (MSEt = 0.367 ± 0.991; Rd = 3.363 ± 1.098). Finally, we demonstrated that bronchodilator use increased dynamic compliance, as well as reduced damping and peripheral resistance. CONCLUSIONS: Taken together, these results show clear evidence of the utility of FO associated with fractional-order modeling in patients with WRA, improving our knowledge of the biomechanical abnormalities and the diagnostic accuracy in this disease.


Subject(s)
Asthma/diagnosis , Asthma/physiopathology , Models, Biological , Respiratory Mechanics , Adult , Biomechanical Phenomena , Case-Control Studies , Female , Humans , Lung/physiopathology , Male , Middle Aged
6.
Med Biol Eng Comput ; 58(10): 2455-2473, 2020 Oct.
Article in English | MEDLINE | ID: mdl-32776208

ABSTRACT

To design machine learning classifiers to facilitate the clinical use and increase the accuracy of the forced oscillation technique (FOT) in the differential diagnosis of patients with asthma and restrictive respiratory diseases. FOT and spirometric exams were performed in 97 individuals, including controls (n = 20), asthmatic patients (n = 38), and restrictive (n = 39) patients. The first experiment of this study showed that the best FOT parameter was the resonance frequency, providing moderate accuracy (AUC = 0.87). In the second experiment, a neuro-fuzzy classifier and different supervised machine learning techniques were investigated, including k-nearest neighbors, random forests, AdaBoost with decision trees, and support vector machines with a radial basis kernel. All classifiers achieved high accuracy (AUC ≥ 0.9) in the differentiation between patient groups. In the third and fourth experiments, the use of different feature selection techniques allowed us to achieve high accuracy with only three FOT parameters. In addition, the neuro-fuzzy classifier also provided rules to explain the classification. Neuro-fuzzy and machine learning classifiers can aid in the differential diagnosis of patients with asthma and restrictive respiratory diseases. They can assist clinicians as a support system providing accurate diagnostic options.


Subject(s)
Asthma/diagnosis , Diagnosis, Computer-Assisted/methods , Respiratory Tract Diseases/diagnosis , Adult , Aged , Algorithms , Area Under Curve , Case-Control Studies , Diagnosis, Differential , Female , Fuzzy Logic , Humans , Machine Learning , Male , Middle Aged , Spirometry , Support Vector Machine
SELECTION OF CITATIONS
SEARCH DETAIL