Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters











Publication year range
1.
Ciênc. rural ; Ciênc. rural (Online);46(1): 83-88, jan. 2016. tab, graf
Article in English | LILACS | ID: lil-767008

ABSTRACT

ABSTRACT: Investigations demonstrate that the wind is the factor that causes the biggest negative influence on water application of sprinkler irrigation systems. Therefore, this paper aims to evaluate, in in-field conditions, the influence of wind on the water distribution uniformity of a mechanical lateral move sprinkler system used for irrigation in rice crop in the South of Rio Grande do Sul State, Brazil. The equipment is located at the Campo Experimental de Terras Baixas (ETB) of EMBRAPA/CPACT and operates with water emitters model I-Wob installed in drop tubes in a distance of 2.8m above the soil surface, having a uniform space of 2.3m between each other and pressure regulators of 68.9kPa. Sixteen in-field evaluations were done and they permitted to infer that the higher is the wind speed, the lower are the values of Christiansen Uniformity (CU) and of Distribution Uniformity (DU) coefficients. Besides, it can be affirmed that even in unfavorable wind conditions, the mechanical lateral move irrigation equipment presented desirable indexes of water application uniformity.


RESUMO: Estudos demonstram que o vento é o fator que causa maior influência negativa na aplicação de água de sistemas de irrigação por aspersão. Sendo assim, este estudo tem por objetivo avaliar, em condições de campo, a influência do vento sobre a uniformidade de distribuição de água de um sistema mecanizado do tipo lateral móvel, utilizado na irrigação de arroz no sul do Rio Grande do Sul. O equipamento, localizado no Campo Experimental de Terras Baixas (ETB) da EMBRAPA/CPACT, opera com emissores de água modelo I-Wob instalados em tubos pendurais a uma distância de 2,8m da superfície do solo, espaçados uniformemente entre si em 2,3m, com reguladores de pressão de 68,9kPa. As 16 avaliações de campo realizadas permitiram inferir que quanto maior a velocidade do vento menor os valores dos coeficientes de uniformidade de Christiansen (CU) e de distribuição (UD). Além disso, pode-se afirmar que, mesmo em condições adversas de vento, o equipamento de irrigação mecanizada do tipo lateral móvel apresentou índices desejáveis de uniformidade de aplicação de água.

2.
Ci. Rural ; 46(1): 83-88, 2016.
Article in English | VETINDEX | ID: vti-379157

ABSTRACT

Investigations demonstrate that the wind is the factor that causes the biggest negative influence on water application of sprinkler irrigation systems. Therefore, this paper aims to evaluate, in in-field conditions, the influence of wind on the water distribution uniformity of a mechanical lateral move sprinkler system used for irrigation in rice crop in the South of Rio Grande do Sul State, Brazil. The equipment is located at the Campo Experimental de Terras Baixas (ETB) of EMBRAPA/CPACT and operates with water emitters model I-Wob installed in drop tubes in a distance of 2.8m above the soil surface, having a uniform space of 2.3m between each other and pressure regulators of 68.9kPa. Sixteen in-field evaluations were done and they permitted to infer that the higher is the wind speed, the lower are the values of Christiansen Uniformity (CU) and of Distribution Uniformity (DU) coefficients. Besides, it can be affirmed that even in unfavorable wind conditions, the mechanical lateral move irrigation equipment presented desirable indexes of water application uniformity.(AU)


Estudos demonstram que o vento é o fator que causa maior influência negativa na aplicação de água de sistemas de irrigação por aspersão. Sendo assim, este estudo tem por objetivo avaliar, em condições de campo, a influência do vento sobre a uniformidade de distribuição de água de um sistema mecanizado do tipo lateral móvel, utilizado na irrigação de arroz no sul do Rio Grande do Sul. O equipamento, localizado no Campo Experimental de Terras Baixas (ETB) da EMBRAPA/CPACT, opera com emissores de água modelo I-Wob instalados em tubos pendurais a uma distância de 2,8m da superfície do solo, espaçados uniformemente entre si em 2,3m, com reguladores de pressão de 68,9kPa. As 16 avaliações de campo realizadas permitiram inferir que quanto maior a velocidade do vento menor os valores dos coeficientes de uniformidade de Christiansen (CU) e de distribuição (UD). Além disso, pode-se afirmar que, mesmo em condições adversas de vento, o equipamento de irrigação mecanizada do tipo lateral móvel apresentou índices desejáveis de uniformidade de aplicação de água.(AU)


Subject(s)
Agricultural Irrigation , Oryza , Wind
3.
Ci. Rural ; 46(1)2016.
Article in English | VETINDEX | ID: vti-709483

ABSTRACT

ABSTRACT: Investigations demonstrate that the wind is the factor that causes the biggest negative influence on water application of sprinkler irrigation systems. Therefore, this paper aims to evaluate, in in-field conditions, the influence of wind on the water distribution uniformity of a mechanical lateral move sprinkler system used for irrigation in rice crop in the South of Rio Grande do Sul State, Brazil. The equipment is located at the Campo Experimental de Terras Baixas (ETB) of EMBRAPA/CPACT and operates with water emitters model I-Wob installed in drop tubes in a distance of 2.8m above the soil surface, having a uniform space of 2.3m between each other and pressure regulators of 68.9kPa. Sixteen in-field evaluations were done and they permitted to infer that the higher is the wind speed, the lower are the values of Christiansen Uniformity (CU) and of Distribution Uniformity (DU) coefficients. Besides, it can be affirmed that even in unfavorable wind conditions, the mechanical lateral move irrigation equipment presented desirable indexes of water application uniformity.


RESUMO: Estudos demonstram que o vento é o fator que causa maior influência negativa na aplicação de água de sistemas de irrigação por aspersão. Sendo assim, este estudo tem por objetivo avaliar, em condições de campo, a influência do vento sobre a uniformidade de distribuição de água de um sistema mecanizado do tipo lateral móvel, utilizado na irrigação de arroz no sul do Rio Grande do Sul. O equipamento, localizado no Campo Experimental de Terras Baixas (ETB) da EMBRAPA/CPACT, opera com emissores de água modelo I-Wob instalados em tubos pendurais a uma distância de 2,8m da superfície do solo, espaçados uniformemente entre si em 2,3m, com reguladores de pressão de 68,9kPa. As 16 avaliações de campo realizadas permitiram inferir que quanto maior a velocidade do vento menor os valores dos coeficientes de uniformidade de Christiansen (CU) e de distribuição (UD). Além disso, pode-se afirmar que, mesmo em condições adversas de vento, o equipamento de irrigação mecanizada do tipo lateral móvel apresentou índices desejáveis de uniformidade de aplicação de água.

4.
Ci. Rural ; 46(1)2016.
Article in English | VETINDEX | ID: vti-709424

ABSTRACT

ABSTRACT: Investigations demonstrate that the wind is the factor that causes the biggest negative influence on water application of sprinkler irrigation systems. Therefore, this paper aims to evaluate, in in-field conditions, the influence of wind on the water distribution uniformity of a mechanical lateral move sprinkler system used for irrigation in rice crop in the South of Rio Grande do Sul State, Brazil. The equipment is located at the Campo Experimental de Terras Baixas (ETB) of EMBRAPA/CPACT and operates with water emitters model I-Wob installed in drop tubes in a distance of 2.8m above the soil surface, having a uniform space of 2.3m between each other and pressure regulators of 68.9kPa. Sixteen in-field evaluations were done and they permitted to infer that the higher is the wind speed, the lower are the values of Christiansen Uniformity (CU) and of Distribution Uniformity (DU) coefficients. Besides, it can be affirmed that even in unfavorable wind conditions, the mechanical lateral move irrigation equipment presented desirable indexes of water application uniformity.


RESUMO: Estudos demonstram que o vento é o fator que causa maior influência negativa na aplicação de água de sistemas de irrigação por aspersão. Sendo assim, este estudo tem por objetivo avaliar, em condições de campo, a influência do vento sobre a uniformidade de distribuição de água de um sistema mecanizado do tipo lateral móvel, utilizado na irrigação de arroz no sul do Rio Grande do Sul. O equipamento, localizado no Campo Experimental de Terras Baixas (ETB) da EMBRAPA/CPACT, opera com emissores de água modelo I-Wob instalados em tubos pendurais a uma distância de 2,8m da superfície do solo, espaçados uniformemente entre si em 2,3m, com reguladores de pressão de 68,9kPa. As 16 avaliações de campo realizadas permitiram inferir que quanto maior a velocidade do vento menor os valores dos coeficientes de uniformidade de Christiansen (CU) e de distribuição (UD). Além disso, pode-se afirmar que, mesmo em condições adversas de vento, o equipamento de irrigação mecanizada do tipo lateral móvel apresentou índices desejáveis de uniformidade de aplicação de água.

5.
Eng. sanit. ambient ; Eng. sanit. ambient;15(3): 223-228, jul.-set. 2010. ilus, tab
Article in Portuguese | LILACS | ID: lil-569087

ABSTRACT

Este trabalho apresenta uma metodologia de campo utilizada para determinar as emissões de biogás através das camadas de cobertura de aterros de resíduos sólidos urbanos, por meio de ensaios simples, diretos e de baixo custo. Os resultados obtidos nesses estudos indicaram que o fluxo de metano (CH4) pode atingir valores de até 150 kg/m². ano, o que representa 630 mil toneladas do CO2eq por ano em um simples aterro de 20 hectares. A espessura da camada de cobertura, que variou entre 0,2 e 0,7 m, não foi um fator relevante nas emissões medidas, enquanto que as pressões de biogás no contato camada-lixo, com valores acima de 500 Pa, favorecem a formação de microfissuras no solo da camada de cobertura, o que eleva as emissões de gases nesses pontos.


This paper presents a field methodology used to determine emissions of biogas through the cover layers of municipal solid waste landfills, by means of simple, straightforward and inexpensive tests. The results from these studies indicated that the flow of methane (CH4) can reach values up to 150 kg/m². year, representing 630,000 tons of CO2eq per year in a mere 20 hectares of landfill. The thickness of the cover layer, which ranged between 0.2 and 0.7 m, was not a relevant factor in the measured emissions, while the pressure of biogas in the contact layer-waste, with values above 500 Pa, favors the formation of microcracks on the soil of the cover layer, which increases the emissions of gases in these points.

SELECTION OF CITATIONS
SEARCH DETAIL