Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters











Database
Language
Publication year range
1.
Micromachines (Basel) ; 14(6)2023 Jun 16.
Article in English | MEDLINE | ID: mdl-37374847

ABSTRACT

Alzheimer's disease (AD) is a neurodegenerative disease with only late-stage detection; thus, diagnosis is made when it is no longer possible to treat the disease, only its symptoms. Consequently, this often leads to caregivers who are the patient's relatives, which adversely impacts the workforce along with severely diminishing the quality of life for all involved. It is, therefore, highly desirable to develop a fast, effective and reliable sensor to enable early-stage detection in an attempt to reverse disease progression. This research validates the detection of amyloid-beta 42 (Aß42) using a Silicon Carbide (SiC) electrode, a fact that is unprecedented in the literature. Aß42 is considered a reliable biomarker for AD detection, as reported in previous studies. To validate the detection with a SiC-based electrochemical sensor, a gold (Au) electrode-based electrochemical sensor was used as a control. The same cleaning, functionalization and Aß1-28 antibody immobilization steps were used on both electrodes. Sensor validation was carried out by means of Cyclic Voltammetry (CV) and Electrochemical Impedance Spectroscopy (EIS) aiming to detect an 0.5 µg·mL-1 Aß42 concentration in 0.1 M buffer solution as a proof of concept. A repeatable peak directly related to the presence of Aß42 was observed, indicating that a fast SiC-based electrochemical sensor was constructed and may prove to be a useful approach for the early detection of AD.

2.
Materials (Basel) ; 14(8)2021 Apr 15.
Article in English | MEDLINE | ID: mdl-33921175

ABSTRACT

There is increasing interest in developing portable technologies to detect human health threats through hybrid materials that integrate specific bioreceptors. This work proposes an electrochemical approach for detecting 3-Phenoxybenzaldehyde (3-PBD), a biomarker for monitoring human exposure to pyrethroid pesticides. The biosensor uses laccase enzymes as an alternative recognition element by direct oxidation of 3-PBD catalysts by the enzyme onto thin-film gold electrodes. The thin-film gold electrode modified by the immobilized laccase was characterized by Fourier-transform infrared spectrometry and scanning electron microscopy. The detection method's electrochemical parameters were established, obtaining a linear range of 5 t 50 µM, the limit of detection, and quantification of 0.061 and 2.02 µM, respectively. The proposed biosensor's analytical performance meets the concentration of pyrethroids detected in natural environments, reflecting its potential as an alternative analytical tool for monitoring the pyrethroid insecticide's presence.

3.
Anal Bioanal Chem ; 411(3): 659-667, 2019 Jan.
Article in English | MEDLINE | ID: mdl-30515537

ABSTRACT

There are increasing concerns regarding the risks arising from the contamination of manipulators of antineoplastic drugs promoted by occupational exposure or even in the dosage of drugs. The present work proposes the use of an electrochemical sensor based on a biopolymer extracted from the babassu coconut (Orbignya phalerata) for the determination of an antineoplastic 5-fluorouracil (5-FU) drug as an alternative for the monitoring of these drugs. In order to reduce the cost of this sensor, a flexible gold electrode (FEAu) is proposed. The surface modification of FEAu was performed with the deposition of a casting film of the biopolymer extracted from the babassu mesocarp (BM) and modified with phthalic anhydride (BMPA). The electrochemical activity of the modified electrode was characterized by cyclic voltammetry (CV), and its morphology was observed by atomic force microscopy (AFM). The FEAu/BMPA showed a high sensitivity (8.8 µA/µmol/L) and low limit of detection (0.34 µmol/L) for the 5-FU drug in an acid medium. Electrochemical sensors developed from the babassu mesocarp may be a viable alternative for the monitoring of the 5-FU antineoplastic in pharmaceutical formulations, because in addition to being sensitive to this drug, they are constructed of a natural polymer, renewable, and abundant in nature. Graphical abstract ᅟ.


Subject(s)
Antimetabolites, Antineoplastic/analysis , Cocos/chemistry , Electrochemical Techniques/instrumentation , Electrodes , Fluorouracil/analysis , Gold/chemistry , Costs and Cost Analysis , Drug Monitoring/instrumentation , Electrodes/economics , Limit of Detection , Microscopy, Atomic Force , Oxidation-Reduction , Phthalic Anhydrides/chemistry , Solubility
SELECTION OF CITATIONS
SEARCH DETAIL