Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 9.951
Filter
1.
J Orthop Surg Res ; 19(1): 385, 2024 Jul 01.
Article in English | MEDLINE | ID: mdl-38951850

ABSTRACT

BACKGROUND: In recent years, the use of tapered-wedge short stems has increased due to their ability to preserve bones and tendons. Surgical techniques occasionally result in a varus position of the stem, which is particularly pronounced in short stems. Although the varus position is not clinically problematic, there are reports of an increased incidence of stress shielding and cortical hypertrophy. Thus, we evaluated and examined the acceptable range of varus angles using finite element analysis. METHODS: Patients diagnosed with osteoarthritis of the hip joint who had undergone arthroplasty were selected and classified into three types [champagne-flute (type A), intermediate (type B), and stovepipe (type C)]. Finite element analysis was performed using Mechanical Finder. The model was created using a Taperloc microplasty stem with the varus angle increased by 1° from 0° to 5° from the bone axis and classified into seven zones based on Gruen's zone classification under loading conditions in a one-leg standing position. The volume of interest was set, the mean equivalent stress for each zone was calculated. RESULTS: A significant decrease in stress was observed in zone 2, and increased stress was observed in zones 3 and 4, suggesting the emergence of a distal periosteal reaction, similar to the results of previous studies. In zone 2, there was a significant decrease in stress in all groups at a varus angle ≥ 3°. In zone 3, stress increased from ≥ 3° in type B and ≥ 4° in type C. In zone 4, there was a significant increase in stress at varus angles of ≥ 2° in types A and B and at ≥ 3° in type C. CONCLUSION: In zone 2, the varus angle at which stress shielding above Engh classification grade 3 may appear is expected to be ≥ 3°. Distal cortical hypertrophy may appear in zones 3 and 4; the narrower the medullary cavity shape, the smaller the allowable angle of internal recession, and the wider the medullary cavity shape, the wider the allowable range. Long-term follow-up is required in patients with varus angles > 3°.


Subject(s)
Arthroplasty, Replacement, Hip , Finite Element Analysis , Hip Prosthesis , Stress, Mechanical , Humans , Arthroplasty, Replacement, Hip/methods , Male , Female , Prosthesis Design , Aged , Osteoarthritis, Hip/surgery , Osteoarthritis, Hip/diagnostic imaging , Middle Aged
2.
J Orthop Surg Res ; 19(1): 384, 2024 Jun 29.
Article in English | MEDLINE | ID: mdl-38951886

ABSTRACT

BACKGROUND: It remains unclear whether the use of an orthopaedic traction table (TT) in direct anterior approach (DAA) total hip arthroplasty (THA) results in better outcomes. The aim of this systematic review and network meta-analysis was to compare the THA outcomes through DAA on a standard operating table and the THA outcomes through DAA on a TT. METHODS: PubMed, Epistemonikos, and Google Scholar were searched for relevant randomized controlled trials (RCTs) up to 01 January 2024. An indirect comparison in network meta-analysis was performed to assess treatment effects between DAA on a TT and DAA on a standard table, using fixed-effects and random-effects models estimated with frequentist approach and consistency assumption. Standardized mean differences (SMDs) with 95% confidence intervals (CIs) were estimated for continuous variables and odds ratios (ORs) with 95% CIs were estimated for binary variables. RESULTS: The systematic review of the literature identified 43 RCTs with a total of 2,258 patients. DAA with TT had a 102.3 mL higher intraoperative blood loss and a 0.6 mmol/L lower Hb 3 days postoperatively compared with DAA without TT (SMD = 102.33, 95% CI 47.62 to 157.04; SMD = - 0.60, 95% CI - 1.19 to - 0.00). DAA with TT had a 0.15 lower periprosthetic fracture OR compared with DAA without TT (OR 0.15, 95% CI 0.03 to 0.86). There were no further significant differences in surgical, radiological, functional outcomes and in complication rates. CONCLUSION: Based on our findings and taking into account the limitations, we recommend that particular attention be paid to the risk of periprosthetic fracture in DAA on a standard operating table and blood loss in DAA with TT. Since numerous other surgical, radiological, functional outcome parameters and other complication rates studied showed no significant difference between DAA on a standard operating table and DAA with TT, no recommendation for a change in surgical technique seems justified. LEVEL OF EVIDENCE: Level I evidence, because this is a systematic review and meta-analysis of randomized controlled trials.


Subject(s)
Arthroplasty, Replacement, Hip , Network Meta-Analysis , Traction , Humans , Arthroplasty, Replacement, Hip/methods , Traction/methods , Treatment Outcome , Blood Loss, Surgical/statistics & numerical data , Operating Tables , Randomized Controlled Trials as Topic , Postoperative Complications/etiology , Postoperative Complications/prevention & control , Postoperative Complications/epidemiology
3.
J Arthroplasty ; 2024 Jul 03.
Article in English | MEDLINE | ID: mdl-38969293

ABSTRACT

BACKGROUND: To gain insight into how clinically relevant improvement in Patient-Reported Outcome Measure (PROM) scores after Total Hip (THA) and Total Knee Arthroplasty (TKA) may be under- or overestimated, we compared PROM respondents and non-respondents on their adverse event rates and assessed whether adverse event occurrence was associated with clinically relevant PROM improvement from those without adverse events. METHODS: All primary THAs and TKAs performed in 19 Dutch hospitals between January 2017 and December 2019 were included. The Hip disability and Osteoarthritis Outcome Score-Physical function Short form (HOOS-PS) and Knee injury and Osteoarthritis Outcome Score-Physical function Short form (KOOS-PS) were used to assess the physical function after THA and TKA, respectively. Adverse events included 1-year revision, 30-day readmission, 30-day complications, and long (i.e., > 75th percentile) length-of-stay (LOS). A clinically relevant improvement was defined as at least a 10-point decrease in HOOS-PS and 9 points in KOOS-PS scores. Associations between adverse events and clinically relevant HOOS-PS and KOOS-PS improvement were assessed using binary logistic regression models adjusted for patient characteristics and clustering of patients within hospitals. RESULTS: There were 20,338 THA and 18,082 TKA procedures included. Adverse events mostly occurred more frequently in HOOS-PS and KOOS-PS non-respondents than in respondents. The THA patients experiencing revision, complications, or long LOS were less likely to experience clinically relevant HOOS-PS improvements (odds ratios of 0.11 [0.06 to 0.20], 0.44 [0.30 to 0.63], and 0.66 [0.50 to 0.88], respectively). The TKA patients experiencing revision or long LOS were less likely to experience clinically relevant KOOS-PS improvements (odds ratios of 0.26 [0.12 to 0.55] and 0.63 [0.50 to 0.80], respectively). CONCLUSION: Clinically-relevant HOOS-PS and KOOS-PS improvements are likely overestimated, as non-respondents had higher adverse event rates which were associated with lower likelihood to achieve clinically-relevant HOOS-PS and KOOS-PS improvements.

4.
J Arthroplasty ; 2024 Jul 03.
Article in English | MEDLINE | ID: mdl-38969294

ABSTRACT

BACKGROUND: Obesity is a risk factor for end-stage hip osteoarthritis (OA). While total hip arthroplasty (THA) is commonly performed to reduce pain and improve function associated with OA, obesity has been associated with an increased risk of complications after THA. Although bariatric surgery may also be utilized to reduce weight, the impact of bariatric surgery on THA outcomes remains inadequately understood. METHODS: This retrospective cohort analysis utilized multicenter electronic medical record data ranging from 2003 to 2023. Patients who have obesity who underwent THA were stratified based on prior bariatric surgery. The final bariatric cohort comprised 451 patients after propensity score matching. Complication rates and revision risks were compared between cohorts at six, 24, and 72 months. Additional analysis stratified patients by interval between bariatric surgery and THA. RESULTS: At six-month follow-up, the bariatric cohort had significantly lower risks of surgical site infection (SSI), wound dehiscence, and deep vein thrombosis (DVT). At 24 months, the bariatric cohort had a lower risk of DVT. At 72 month follow-up, the bariatric cohort had reduced rates of revision, mortality, cardiac morbidity, and Clavien-Dindo grade IV complications. CONCLUSION: Obese patients who underwent bariatric surgery prior to THA experienced reduced medical complications at all time points and reduced rates of revision at 72 months relative to a matched cohort who did not undergo bariatric surgery.

5.
BMC Musculoskelet Disord ; 25(1): 510, 2024 Jul 03.
Article in English | MEDLINE | ID: mdl-38961446

ABSTRACT

PURPOSE: Crowe IV developmental dysplasia of the hip (DDH) is a catastrophic hip disease. Moreover, obtaining ideal clinical efficacy in conventional total hip arthroplasty (THA) is often difficult. In this study, we aimed to assess the mid-term clinical results of THA with porous tantalum trabecular metal (TM) pads for acetabular reconstruction in the treatment of Crowe IV DDH. METHODS: A cohort of 28 patients (32 hips) diagnosed with Crowe type IV DDH who underwent acetabular reconstruction during THA using TM pads with scheduled follow-up between 2011 and 2018, were included in this study. Eight cases were men and 24 were women, with a mean age of 48.4 years (range, 36-72 years) and a mean follow-up was 74.3 months (range, 42-132 months). All patients underwent acetabular reconstruction using TM pads and total hip replacement with subtrochanteric osteotomy. RESULTS: At the final follow-up, 28 hips (87.5%) demonstrated mild or no postoperative limping. The Harris Hip Score improved from 58.4 ± 10.6 preoperatively to 85.6 ± 8.9. The mean pain, stiffness, and function scores on the Western Ontario and McMaster University Osteoarthritis index were 86.5 ± 10.2, 87.3 ± 12.4 and 85.4 ± 11.6 respectively. The mean score of patient satisfaction was 90.4 ± 7.6. Additionally, the SF-12 physical summary score was 41.8 ± 5.6 and the SF-12 mental summary score was 51.6 ± 5.4. TM construct survivorship due to all-cause failure was 90.6% at 5 years with 3 hips at risk, 87.5% at 10 years with 4 hips at risk. The survivorship due to failure from aseptic loosening was 96.9% at 5 years with 1hips at risk and 93.75% at 10 years with 2 hips at risk. CONCLUSION: This study demonstrated satisfactory mid-term clinical and radiological results with the application of TM pads for acetabular reconstruction combined with THA in patients with Crowe IV DDH. TRIAL REGISTRATION NUMBER: ChiCTR1800014526, Date: 18/01/2018.


Subject(s)
Arthroplasty, Replacement, Hip , Developmental Dysplasia of the Hip , Hip Prosthesis , Tantalum , Humans , Arthroplasty, Replacement, Hip/instrumentation , Arthroplasty, Replacement, Hip/methods , Middle Aged , Female , Male , Aged , Adult , Follow-Up Studies , Developmental Dysplasia of the Hip/surgery , Developmental Dysplasia of the Hip/diagnostic imaging , Treatment Outcome , Acetabulum/surgery , Acetabulum/diagnostic imaging , Prosthesis Design , Retrospective Studies , Porosity
6.
Sci Rep ; 14(1): 15458, 2024 07 04.
Article in English | MEDLINE | ID: mdl-38965266

ABSTRACT

In total hip arthroplasty (THA), determining the center of rotation (COR) and diameter of the hip joint (acetabulum and femoral head) is essential to restore patient biomechanics. This study investigates on-the-fly determination of hip COR and size, using off-the-shelf augmented reality (AR) hardware. An AR head-mounted device (HMD) was configured with inside-out infrared tracking enabling the determination of surface coordinates using a handheld stylus. Two investigators examined 10 prosthetic femoral heads and cups, and 10 human femurs. The HMD calculated the diameter and COR through sphere fitting. Results were compared to data obtained from either verified prosthetic geometry or post-hoc CT analysis. Repeated single-observer measurements showed a mean diameter error of 0.63 mm ± 0.48 mm for the prosthetic heads and 0.54 mm ± 0.39 mm for the cups. Inter-observer comparison yielded mean diameter errors of 0.28 mm ± 0.71 mm and 1.82 mm ± 1.42 mm for the heads and cups, respectively. Cadaver testing found a mean COR error of 3.09 mm ± 1.18 mm and a diameter error of 1.10 mm ± 0.90 mm. Intra- and inter-observer reliability averaged below 2 mm. AR-based surface mapping using HMD proved accurate and reliable in determining the diameter of THA components with promise in identifying COR and diameter of osteoarthritic femoral heads.


Subject(s)
Arthroplasty, Replacement, Hip , Augmented Reality , Femur Head , Hip Prosthesis , Humans , Femur Head/surgery , Femur Head/diagnostic imaging , Arthroplasty, Replacement, Hip/instrumentation , Arthroplasty, Replacement, Hip/methods , Tomography, X-Ray Computed , Rotation , Male , Hip Joint/surgery , Hip Joint/diagnostic imaging , Female
7.
Orthop Surg ; 2024 Jul 01.
Article in English | MEDLINE | ID: mdl-38951965

ABSTRACT

OBJECTIVE: Total hip arthroplasty (THA) remains the primary treatment option for femoral neck fractures in elderly patients. This study aims to explore the risk factors associated with allogeneic blood transfusion after surgery and to develop a dynamic prediction model to predict post-operative blood transfusion requirements. This will provide more accurate guidance for perioperative humoral management and rational allocation of medical resources. METHODS: We retrospectively analyzed data from 829 patients who underwent total hip arthroplasty for femoral neck fractures at three third-class hospitals between January 2017 and August 2023. Patient data from one hospital were used for model development, whereas data from the other two hospitals were used for external validation. Logistic regression analysis was used to screen the characteristic subsets related to blood transfusion. Various machine learning algorithms, including logistic regression, SVA (support vector machine), K-NN (k-nearest neighbors), MLP (multilayer perceptron), naive Bayes, decision tree, random forest, and gradient boosting, were used to process the data and construct prediction models. A 10-fold cross-validation algorithm facilitated the comparison of the predictive performance of the models, resulting in the selection of the best-performing model for the development of an open-source computing program. RESULTS: BMI (body mass index), surgical duration, IBL (intraoperative blood loss), anticoagulant history, utilization rate of tranexamic acid, Pre-Hb, and Pre-ALB were included in the model as well as independent risk factors. The average area under curve (AUC) values for each model were as follows: logistic regression (0.98); SVA (0.91); k-NN (0.87) MLP, (0.96); naive Bayes (0.97); decision tree (0.87); random forest (0.96); and gradient boosting (0.97). A web calculator based on the best model is available at: (https://nomo99.shinyapps.io/dynnomapp/). CONCLUSION: Utilizing a computer algorithm, a prediction model with a high discrimination accuracy (AUC > 0.5) was developed. The logistic regression model demonstrated superior differentiation and reliability, thereby successfully passing external validation. The model's strong generalizability and applicability have significant implications for clinicians, aiding in the identification of patients at high risk for postoperative blood transfusion.

8.
Arthroplast Today ; 27: 101407, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38946922

ABSTRACT

Immunoglobulin A (IgA) nephropathy in the presence of a metal-on-metal (MoM) hip arthroplasty is a rare condition that requires close monitoring. A 61-year-old male with bilateral hip osteoarthritis underwent resurfacing hip arthroplasty with MoM articulating surfaces. Prior to his four-year postoperative visit, the patient was diagnosed with IgA nephropathy. During this visit, the patient reported clicking in the left resurfacing hip arthroplasty, and serum metal ions were significantly elevated. Consequently, the patient underwent conversion to bilateral ceramic-on-cross-linked polyethylene total hip arthroplasty, which resulted in the restoration of metal ion levels to normal. This case highlights that IgA nephropathy played a critical role in impeding the clearance of metal ions. Routine metal ion counts are warranted in patients with MoM articulating interfaces and a newly diagnosed nephropathy.

9.
Arthroplast Today ; 27: 101435, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38946923

ABSTRACT

Background: Trabecular metal augments (TMAs) have been extensively used in revision total hip arthroplasty (THA) to address acetabular bone defects. However, limited data exists regarding TMA utilization during primary THA. This study aims to assess the clinical and radiographic outcomes of TMAs used during primary THA. Methods: A single-institution retrospective case series of primary THA patients treated with TMA between 2010 and 2019 was performed. Patient demographics, complications, and revisions were recorded. Cup position, center of rotation, leg length, and radiolucent lines were assessed radiographically. The Kaplan-Meier method was used to compute implant survivorship. Results: Twenty-six patients (30 hips) were included with average age of 52.6 ± 15.3 years (range: 22-78) and mean follow-up of 4.1 ± 2.1 years (range: 2.0-8.9). Most TMAs were indicated for developmental dysplasia of the hip (n = 18; 60.0%). On average, hip center of rotation was lowered 1.5 ± 1.3 cm and lateralized 1.2 ± 1.5 cm, while leg length and global offset were increased by 2.4 ± 1.2 cm and 0.4 ± 1.0 cm, respectively. At final follow-up, 3 hips (10.0%) required revision: one (3.3%) for aseptic loosening and 2 (6.7%) for instability. No patients had progressive radiolucent lines at final follow-up. Five-year survival with aseptic loosening and all-cause revision as endpoints was 100% (95% confidence interval: 90.0%-100.0%) and 92.1% (95% confidence interval: 81.3%-100.0%), respectively. One patient required revision for aseptic loosening after the 5-year mark. Conclusions: Trabecular metal augmentation during primary THA demonstrates satisfactory early to mid-term outcomes. TMA is a viable option for complex primary THA when bone loss is encountered or secondary support is required. Level of Evidence: Level IV.

10.
Arthroplast Today ; 27: 101433, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38946925

ABSTRACT

Background: This study aimed to investigate the relationship between 3-dimensional (3D) alignment and postoperative bone mineral density (BMD) changes with Accolade II tapered wedge stems, which have a different proximal shape from other tapered wedge stems, up to 5 years after primary total hip arthroplasty. Methods: We retrospectively analyzed the hips of 89 patients who underwent total hip arthroplasty using the second-generation proximally coated cementless stem (Accolade II; Stryker Orthopedics, Mahwah, NJ) at our institution from 2014 to 2018 over a 5-year follow-up. We evaluated the relationship between stem alignment, measured using 3D-templating software, and BMD changes in the 7 Gruen zones and compared the data with those from a former study using other short taper-wedge stems. Results: BMDs in zones 1 and 7 continued to decrease gradually every year after surgery, and BMD in zone 7 showed the largest decrease (21%) from baseline over 5 years. No correlation was found between stem alignment (varus/valgus, flexion/extension, and anteversion/retroversion) and changes in BMD in each zone over 5 years. Conclusions: Our data showed no correlation between 3D stem alignment and changes in BMD in each Gruen zone over 5 years. This suggests that the Accolade II stem may fit better into any shape of the proximal medullary canal because of its unique characteristics.

11.
World J Orthop ; 15(6): 501-511, 2024 Jun 18.
Article in English | MEDLINE | ID: mdl-38947255

ABSTRACT

Total hip arthroplasty (THA) is one of the most successful elective operations in orthopedic surgery for improving pain and functional disability in patients with end-stage joint disease. However, dislocation continues to be a troublesome complication after THA, as it is a leading cause of revision and is associated with substantial social, health, and economic costs. It is a relatively rare, usually early occurrence that depends on both the patients' characteristics and the surgical aspects. The most recent and important finding is the special attention to be given preoperatively to spinopelvic mobility, which is closely related to the incidence of dislocation. Consequently, clinical and radiographic assessment of the lumbar spine is mandatory to identify an altered pelvic tilt that could suggest a different positioning of the cup. Lumbar spinal fusion is currently considered a risk factor for dislocation and revision regardless of whether it is performed prior to or after THA. Surgical options for its treatment and prevention include the use of prostheses with large diameter of femoral head size, dual mobility constructs, constrained liners, and modular neck stems.

12.
World J Orthop ; 15(6): 554-559, 2024 Jun 18.
Article in English | MEDLINE | ID: mdl-38947266

ABSTRACT

BACKGROUND: Hip resurfacing arthroplasty (HRA) is an alternative to total hip arthroplasty (THA) that is typically reserved for young active patients because it preserves bone. However, the benefits of HRA only hold true if conversion THA after failed HRA provides acceptable outcomes. AIM: To compare patient reported outcomes for conversion THA after HRA failure to primary THA. METHODS: A retrospective review of 36 patients (37 hips) that underwent conversion THA for failed HRA between October 2006 and May 2019 by a single surgeon was performed. Patient reported outcomes [modified Harris Hip Score (mHHS), University of California Los Angeles (UCLA) activity score] were obtained via an email-based responder-anonymous survey. Outcomes were compared to normative data of a primary THA cohort with similar demographics. Subgroup analysis was performed comparing outcomes of conversion THA for adverse local tissue reaction (ALTR) vs all other causes for failure. RESULTS: The study group had a lower mHHS than the control group (81.7 ± 13.8 vs 90.2 ± 11.6, P < 0.01); however, both groups had similar UCLA activity levels (7.5 ± 2.3 vs 7.2 ± 1.6, P = 0.51). Patients that underwent conversion for non-ATLR causes had similar mHHS (85.2 ± 11.5 vs 90.2 ± 11.6, P = 0.11) and higher UCLA activity levels (8.5 ± 1.8 vs 7.2 ± 1.6, P < 0.01) compared to the control group. Patients that underwent conversion for ATLR had worse mHHS (77.1 ± 14.5 vs 90.2 ± 11.6, P < 0.01) and UCLA activity levels (6.1 ± 2.3 vs 7.2 ± 1.6, P = 0.05) when compared to the control group. CONCLUSION: Patient outcomes equivalent to primary THA can be achieved following HRA conversion to THA. However, inferior outcomes were demonstrated for ALTR-related HRA failure. Patient selection and perhaps further studies examining alternative HRA bearing surfaces should be considered.

13.
World J Orthop ; 15(6): 512-519, 2024 Jun 18.
Article in English | MEDLINE | ID: mdl-38947268

ABSTRACT

Dual mobility (DM) bearings have gained significant attention in the field of total hip arthroplasty (THA) as a valid treatment option in cases of revision for instability after THA whereas its use in primary THA is still a matter of debate. This manuscript explores the pathology, incidence, diagnosis, treatment options, prognosis, ongoing studies in the literature, and future perspectives related to the use of DM bearings employed in primary THA. DM bearings are primarily designed to address one of the major concerns in THA: Instability of the prosthetic hip. Instability is both for the surgeon and the patient a devastating postoperative complication, leading to significant pain and subsequent apprehension by the patient and may require revision surgeries. The use of DM implants poses the worry of wear-related complications, such as accelerated polyethylene wear and osteolysis, which also pose challenges to long-term implant survival. This technique has seen a steady rise in recent years, with multiple studies reporting favorable outcomes. The incidence of their utilization varies among institutions and surgeons, reflecting differing preferences and patient populations. The diagnosis of instability and wear-related complications in THA often involves clinical assessment, imaging modalities such as X-rays, computed tomography scans, and sometimes advanced imaging techniques like magnetic resonance imaging. DM bearings can be considered as an option when patients present neurologic pathologies such as Parkinson's disease or recurrent dislocations after THA. DM bearings provide an additional articulation point within the implant, facilitating a greater range of motion and inherent stability. This design allows for reduced risk of dislocation and improved functional outcomes. Various implant manufacturers offer different designs and sizes of DM bearings to suit individual patient needs. Current literature suggests that the use of DM bearings in primary THA has demonstrated promising outcomes in terms of enhanced stability, reduced dislocation rates, and improved patient satisfaction. However, long-term studies with larger patient cohorts are necessary to establish the durability and longevity of these implants. Several ongoing studies are investigating the role of DM bearings in primary THA. These studies focus on evaluating long-term implant survivorship, assessing wear patterns, analyzing patient-reported outcomes, and comparing the effectiveness of DM bearings with traditional THA designs. The future of DM bearings in primary THA holds potential for further advancements. Research efforts are aimed at refining implant materials, optimizing designs, and studying the influence of surgical techniques on implant performance. Additionally, continued investigation into the long-term outcomes and cost-effectiveness of DM bearings will play a crucial role in shaping their future use. While further research is warranted, the current evidence supports their potential as a beneficial solution in improving surgical outcomes and patient satisfaction.

14.
EFORT Open Rev ; 9(7): 615-624, 2024 Jul 01.
Article in English | MEDLINE | ID: mdl-38949153

ABSTRACT

Total joint arthroplasty (TJA) is rising globally, with an associated increase in associated complications, necessitating increased efforts in prevention of these complications with pre-operative optimisation. Malnutrition has been highlighted as one of the most important pre-operative modifiable risk factors to be addressed in TJA, with the term malnutrition in orthopaedic surgery having a broad definition that encompasses a wide range of nutritional abnormalities from undernutrition to overnutrition contributing to the outcomes of TJA. Complications associated with malnutrition include periprosthetic joint infection (PJI), periprosthetic fracture, dislocations, aseptic loosening, anaemia, prolonged length of stay (LOS), increased mortality, and raised health care costs. Standardised nutritional scoring tools, anthropometric measurements, and serological markers are all options available in pre-operative nutritional assessment in TJA, but there is no consensus yet regarding the standardisation of what parameters to assess and how to assess them. Abnormal parameters identified using any of the assessment methods results in the diagnosis of malnutrition, and correction of these parameters of overnutrition or undernutrition have shown to improve outcomes in TJA. With the multiple nutritional parameters contributing to the success of total joint arthroplasty, it is imperative that orthopaedic surgeon has a thorough knowledge regarding nutritional peri-operative optimisation in TJA.

15.
EFORT Open Rev ; 9(7): 632-645, 2024 Jul 01.
Article in English | MEDLINE | ID: mdl-38949170

ABSTRACT

Purpose: To assess utility, benefits, and risks of 4th-generation alumina-zirconia ceramic pairings in elective total hip arthroplasty (THA). Methods: A comprehensive mixed-methods best-evidence synthesis using data from systematic reviews, randomized controlled trials (RCTs), prospective and retrospective cohort studies, as well as joint replacement registries, was conducted to estimate overall revision and survival rates, periprosthetic infection, bearing fractures, and noise phenomena with 4th-generation alumina-zirconia ceramic versus other tribological couplings in elective THA. The systematic review part across multiple databases was registered with PROSPERO (CRD42023418076), and individual study data were extracted for statistical re-analysis. Results: Twenty overlapping systematic reviews, 7, 17, and 8 references from RCTs, cohort studies, and joint replacement registries form the basis of this work. According to current best evidence, it is (i) 15-33 times more likely that 4th-generation alumina-zirconia pairings avoid a revision for infection than causing a revision for audible noise, (ii) 38-85 times more likely that 4th-generation alumina-zirconia pairings avoid a revision for infection than causing a revision for ceramic head fractures, and (iii) three to six times more likely that 4th-generation alumina-zirconia pairings avoid a revision for infection than cause a revision for ceramic liner fractures. Conclusion: Fourth-generation alumina-zirconia pairings in THA show a favorable benefit-risk ratio, with rare compound-specific adverse events and complications significantly outbalanced by long-term advantages, such as a markedly lower incidence of revision for infection.

16.
J Orthop ; 57: 17-22, 2024 Nov.
Article in English | MEDLINE | ID: mdl-38948502

ABSTRACT

Introduction: Short stem prostheses were originally designed for younger and more active patients. In recent years, they have been increasingly offered to older patients. This study evaluates the mid-to long-term survival of a short stem prosthesis and the changes in periprosthetic bone density following implantation of a cementless short hip stem in patients over 60 years of age. Methods: 118 patients aged over 60 received short stem prostheses. Clinical examination included Harris Hip Score (HHS) and Hip Disability and Osteoarthritis Outcome Score (HOOS). 93 patients were followed clinically for at least five years. 53 patients underwent dual-energy x-ray absorptiometry (DXA) and radiographic evaluation. Follow-up intervals were preoperative and postoperative (t0), at approximately six months (t1), at approximately two years (t2), and at approximately five years or later (t3). Results: Over a mean 6.7-year observation period for all 118 patients, one stem revision occurred due to a traumatic periprosthetic stem fracture. The five-year survival rate for the endpoint survival of the Metha® stem in 95 at-risk patients is 99.2%. HHS improved significantly from t0 55.3 ± 11.5 (range 30-79) to t3 95.3 ± 8.6 (range 57-100) at a mean of 8.0 years (p < 0.001). HOOS improved significantly in each subscale (p < 0.001). Bone mineral density (BMD) was available for review in 53 patients after a mean of 7.1 years. BMD increased from t0 to t3 in region of interest (ROI) 3 (+0.4%) and ROI 6 (+2.9%) and decreased in ROI 1 (-10.3%), ROI 2 (-9.8%), ROI 4 (-5.3%), ROI 5 (-3.4%) and ROI 7 (-23.1%). Conclusions: The evaluated short stem prosthesis shows a remarkably high survival rate in elderly patients, accompanied by excellent clinical results. Load transfer measurements show a metaphyseal-diaphyseal pattern with a trend towards increased diaphyseal transfer over the period observed.

17.
Arthroplast Today ; 28: 101430, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38983939

ABSTRACT

Background: This study investigates the association between the Geriatric Nutritional Risk Index (GNRI), a measure of malnutrition risk, and 30-day postoperative complications following revision total hip arthroplasty (rTHA). Methods: The American College of Surgeons National Surgical Quality Improvement Program database was queried for all patients ≥65 who underwent aseptic rTHA between 2015 and 2021. The final study population (n = 7119) was divided into 3 groups based on preoperative GNRI: normal/reference (GNRI >98) (n = 4342), moderate malnutrition (92 ≤ GNRI ≤98) (n = 1367), and severe malnutrition (GNRI <92) (n = 1410). Multivariate logistic regression analysis was conducted to investigate the association between preoperative GNRI and 30-day postoperative complications. Results: After controlling for significant covariates, the risk of experiencing any postoperative complications was significantly higher with both moderate (odds ratio [OR] 2.08, P < .001) and severe malnutrition (OR 8.79, P < .001). Specifically, moderate malnutrition was independently and significantly associated with deep vein thrombosis (OR 1.01, P = .044), blood transfusions (OR 1.78, P < .001), nonhome discharge (OR 1.83, P < .001), readmission (OR 1.27, P = .035), length of stay >2 days (OR 1.98, P < .001), and periprosthetic fracture (OR 1.54, P = .020). Severe malnutrition was independently and significantly associated with sepsis (OR 3.67, P < .001), septic shock (OR 3.75, P = .002), pneumonia (OR 2.73, P < .001), urinary tract infection (OR 2.04, P = .002), deep vein thrombosis (OR 1.01, P = .001), pulmonary embolism (OR 2.47, P = .019), acute renal failure (OR 8.44, P = .011), blood transfusions (OR 2.78, P < .001), surgical site infection (OR 2.59, P < .001), nonhome discharge (OR 3.36, P < .001), readmission (OR 1.69, P < .001), unplanned reoperation (OR 1.97, P < .001), length of stay >2 days (OR 5.41, P < .001), periprosthetic fractures (OR 1.61, P = .015), and mortality (OR 2.63, P < .001). Conclusions: Malnutrition has strong predictive value for short-term postoperative complications and has potential as an adjunctive risk stratification tool for geriatric patients undergoing rTHA.

18.
Arthroplast Today ; 28: 101385, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38983942

ABSTRACT

Background: Revision total knee (TKR) and hip (THR) arthroplasty surgeries are disincentivized due to unfavorable reimbursement rates, surgical times, and complication rates. Our study investigates secondary benefits of performing these surgeries by generating subsequent cases for surgeons and practices. Methods: Patients undergoing TKR and THR between April 1, 2011, and January 1, 2019, at our tertiary academic institution were analyzed. Patients were identified with Current Procedural Terminology codes for TKR and THR. We calculated a subsequent surgery rate on the same or different joint by the initial surgeon or another surgeon within the practice to determine the procedure yield after initial revision arthroplasty. Results: One thousand six hundred twenty-five patients met inclusion criteria. Six hundred forty-nine (39.9%) patients received at least one subsequent procedure on any joint by any orthopaedic surgeon in the practice. Four hundred five patients (24.9%) underwent another procedure on any joint by the same surgeon. Two hundred sixty patients (16.0%) underwent another procedure on the same joint by the same surgeon, with 109 cases (41.9%) being a planned second stage of a 2-stage revision for infection. Two hundred eighty-five patients (17.5%) underwent another procedure on a different joint by the same surgeon, with 122 of these patients (42.8%) undergoing at least one primary total hip or knee arthroplasty. Conclusions: TKRs and THRs can increase surgeon and practice volumes through the generation of future cases, which are primarily the second stage of a 2-stage revision or primary joint arthroplasties on other joints.

19.
Article in English | MEDLINE | ID: mdl-38960932

ABSTRACT

BACKGROUND: To evaluate the function of the abductor mechanism after a gluteus maximus flap transfer due to a degeneration of the muscles after hip arthroplasty, we analyzed the post-operative functional outcome as well as radiographic effects in muscle tissue. METHODS: This present study included six consecutive patients operatively treated with a gluteus maximus flap due to chronic gluteal deficiency after total hip arthroplasty. All patients presented a preoperative severe limp, hip abductor deficiency and a history of conservative treatment without the relief of symptoms. MRI scans were performed pre- and postoperatively to evaluate the muscle volume and grade of degeneration of the abductor mechanism. For clinical evaluation, the Harris hip score (HHS) was applied pre- and postoperatively. Moreover, the intensity of pain, the Trendelenburg sign, the internal rotation lag sign and the abductor muscle force were measured before and after surgery. RESULTS: Overall, the evaluation of the Magnetic Resonance Imaging (MRI) showed no significant changes in total muscle volume during the follow-up period. Separate measurements presented a significant growth of muscle volume for the gluteus minimus and tensor fascia lata compared to preoperative imaging during the follow-up period. The amount of fat volume decreased for all the measured muscles with statistical significance for the gluteus minimus, the gluteus medius and the tensor fascia lata. No further muscle degeneration and no flap necrosis were measured. The postoperative HHS results were not statistically significant compared to the preoperative results. CONCLUSIONS: Besides fair clinical results, the radiological measurements indicate that the flap transfer enables functional muscular tissue recovery and prevents further degeneration. Given these conditions, the gluteus maximus muscle flap transfer represents a viable treatment option for patients with chronic gluteal deficiency in selected patients.

20.
Arthroplast Today ; 27: 101420, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38966329

ABSTRACT

Background: Although there have been several studies describing risk factors for complications after outpatient total hip arthroplasty (THA), data describing the timing of such complications is lacking. Methods: Patients who underwent outpatient or inpatient primary THA were identified in the 2012-2019 National Surgical Quality Improvement Program database. For 9 different 30-day complications, the median postoperative day of diagnosis was determined. Multivariable regressions were used to compare the risk of each complication between outpatient vs inpatient groups. Multivariable Cox proportional hazards modeling was used to evaluate the differences in the timing of each adverse event between the groups. Results: After outpatient THA, the median day of diagnosis for readmission was 12.5 (interquartile range 5-22), surgical site infection 15 (2-21), urinary tract infection 13.5 (6-19.5), deep vein thrombosis 13 (8-21), myocardial infarction 4.5 (1-7), pulmonary embolism 15 (8-25), sepsis 16 (9-26), stroke 2 (0-7), and pneumonia 6.5 (3-10). On multivariable regressions, outpatients had a lower relative risk (RR) of readmission (RR = 0.73), surgical site infection (RR = 0.72), and pneumonia (RR = 0.1), all P < .05. On multivariable cox proportional hazards modeling, there were no statistically significant differences in the timing of each complication between outpatient vs inpatient procedures (P > .05). Conclusions: The timing of complications after outpatient THA was similar to inpatient procedures. Consideration should be given to lowering thresholds for diagnostic testing after outpatient THA for each complication during the at-risk time periods identified here. Although extremely rare, this is especially important for catastrophic adverse events, which tend to occur early after discharge.

SELECTION OF CITATIONS
SEARCH DETAIL
...