Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 594
Filter
1.
JACC Adv ; 3(3): 100839, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38938839

ABSTRACT

Background: Augmented reality (AR) guidance holds potential to improve transcatheter interventions by enabling visualization of and interaction with patient-specific 3-dimensional virtual content. Positioning of cerebral embolic protection devices (CEP) during transcatheter aortic valve replacement (TAVR) increases patient exposure to radiation and iodinated contrast, and increases procedure time. AR may enhance procedural guidance and facilitate a safer intervention. Objectives: The purpose of this study was to develop and test a novel AR guidance system with a custom user interface that displays virtual, patient-specific 3-dimensional anatomic models, and assess its intraprocedural impact during CEP placement in TAVR. Methods: Patients undergoing CEP during TAVR were prospectively enrolled and assigned to either AR guidance or control groups. Primary endpoints were contrast volume used prior to filter placement, times to filter placement, and fluoroscopy time. Postprocedure questionnaires were administered to assess intraprocedural physician experience with AR guidance. Results: A total of 24 patients presenting for TAVR were enrolled in the study (12 with AR guidance and 12 controls). AR guidance eliminated the need for aortic arch angiograms prior to device placement thus reducing contrast volume (0 mL vs 15 mL, P < 0.0001). There was no significant difference in the time required for filter placement or fluoroscopy time. Postprocedure questionnaires indicated that AR guidance increased confidence in wiring of the aortic arch and facilitated easier device placement. Conclusions: We developed a novel AR guidance system that eliminated the need for additional intraprocedural angiograms prior to device placement without any significant difference in time to intervention and offered a subjective improvement in performance of the intervention.

2.
Nanomaterials (Basel) ; 14(12)2024 Jun 20.
Article in English | MEDLINE | ID: mdl-38921935

ABSTRACT

Magnetic particle hyperthermia (MPH) enables the direct heating of solid tumors with alternating magnetic fields (AMFs). One challenge with MPH is the unknown particle distribution in tissue after injection. Magnetic particle imaging (MPI) can measure the nanoparticle content and distribution in tissue after delivery. The objective of this study was to develop a clinically translatable protocol that incorporates MPI data into finite element calculations for simulating tissue temperatures during MPH. To verify the protocol, we conducted MPH experiments in tumor-bearing mouse cadavers. Five 8-10-week-old female BALB/c mice bearing subcutaneous 4T1 tumors were anesthetized and received intratumor injections of Synomag®-S90 nanoparticles. Immediately following injection, the mice were euthanized and imaged, and the tumors were heated with an AMF. We used the Mimics Innovation Suite to create a 3D mesh of the tumor from micro-computerized tomography data and spatial index MPI to generate a scaled heating function for the heat transfer calculations. The processed imaging data were incorporated into a finite element solver, COMSOL Multiphysics®. The upper and lower bounds of the simulated tumor temperatures for all five cadavers demonstrated agreement with the experimental temperature measurements, thus verifying the protocol. These results demonstrate the utility of MPI to guide predictive thermal calculations for MPH treatment planning.

3.
Phys Imaging Radiat Oncol ; 30: 100594, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38883146

ABSTRACT

Background and purpose: Active breathing motion management in radiotherapy consists of motion monitoring, quantification and mitigation. It is impacted by associated latencies of a few 100 ms. Artificial neural networks can successfully predict breathing motion and eliminate latencies. However, they require usually a large dataset for training. The objective of this work was to demonstrate that explicitly encoding the cyclic nature of the breathing signal into the training data enables significant reduction of training datasets which can be obtained from healthy volunteers. Material and methods: Seventy surface scanner breathing signals from 25 healthy volunteers in anterior-posterior direction were used for training and validation (ratio 4:1) of long short-term memory models. The model performance was compared to a model using decomposition into phase, amplitude and a time-dependent baseline. Testing of the models was performed on 55 independent breathing signals in anterior-posterior direction from surface scanner (35 lung, 20 liver) of 30 patients with a mean breathing amplitude of (5.9 ± 6.7) mm. Results: Using the decomposed breathing signal allowed for a reduction of the absolute root-mean square error (RMSE) from 0.34 mm to 0.12 mm during validation. Testing using patient data yielded an average absolute RMSE of the breathing signal of (0.16 ± 0.11) mm with a prediction horizon of 500 ms. Conclusion: It was demonstrated that a motion prediction model can be trained with less than 100 datasets of healthy volunteers if breathing cycle parameters are considered. Applied to 55 patients, the model predicted breathing motion with a high accuracy.

4.
Med Image Anal ; 96: 103221, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38824864

ABSTRACT

Image-guided surgery collocates patient-specific data with the physical environment to facilitate surgical decision making. Unfortunately, these guidance systems commonly become compromised by intraoperative soft-tissue deformations. Nonrigid image-to-physical registration methods have been proposed to compensate for deformations, but clinical utility requires compatibility of these techniques with data sparsity and temporal constraints in the operating room. While finite element models can be effective in sparse data scenarios, computation time remains a limitation to widespread deployment. This paper proposes a registration algorithm that uses regularized Kelvinlets, which are analytical solutions to linear elasticity in an infinite domain, to overcome these barriers. This algorithm is demonstrated and compared to finite element-based registration on two datasets: a phantom liver deformation dataset and an in vivo breast deformation dataset. The regularized Kelvinlets algorithm resulted in a significant reduction in computation time compared to the finite element method. Accuracy as evaluated by target registration error was comparable between methods. Average target registration errors were 4.6 ± 1.0 and 3.2 ± 0.8 mm on the liver dataset and 5.4 ± 1.4 and 6.4 ± 1.5 mm on the breast dataset for the regularized Kelvinlets and finite element method, respectively. Limitations of regularized Kelvinlets include the lack of organ-specific geometry and the assumptions of linear elasticity and infinitesimal strain. Despite limitations, this work demonstrates the generalizability of regularized Kelvinlets registration on two soft-tissue elastic organs. This method may improve and accelerate registration for image-guided surgery, and it shows the potential of using regularized Kelvinlets on medical imaging data.


Subject(s)
Algorithms , Finite Element Analysis , Liver , Phantoms, Imaging , Humans , Liver/diagnostic imaging , Female , Surgery, Computer-Assisted/methods , Breast/diagnostic imaging , Reproducibility of Results , Image Interpretation, Computer-Assisted/methods , Sensitivity and Specificity
5.
Cureus ; 16(5): e60757, 2024 May.
Article in English | MEDLINE | ID: mdl-38903361

ABSTRACT

Background Accurate diagnosis of musculoskeletal tumors is essential for guiding appropriate treatment strategies. Percutaneous core needle biopsy (PCNB) is increasingly recognized as a valuable method for obtaining tissue samples for histopathological examination. This study aims to evaluate the diagnostic accuracy and clinical utility of PCNB in diagnosing musculoskeletal tumors. Methodology A total of 152 cases suspected of musculoskeletal tumors underwent PCNB at our tertiary care center between 2020 and 2023. Pre-biopsy evaluation included comprehensive clinical assessment and imaging studies. Core biopsies were performed under image guidance, with specimens sent for histopathological examination and culture sensitivity analysis. Diagnostic yield, accuracy, and performance metrics of PCNB were assessed. Results PCNB demonstrated a diagnostic yield of 93.4%. However, in cases where initial biopsies were inconclusive, repeat core biopsy or open biopsy provided the necessary diagnostic clarity. PCNB demonstrated a remarkable diagnostic accuracy of 97.9%, with a specificity and positive predictive value of 100%. There were no post-biopsy complications and no instances of local recurrence from the biopsy tract. Conclusions PCNB can be a reliable method for diagnosing musculoskeletal tumors, offering high diagnostic accuracy and minimal complications. The utilization of image guidance enhances precision and reduces the risk of complications. PCNB proves effective in diagnosing both primary tumors and bone infections, facilitating timely and appropriate treatment strategies in orthopedic oncology.

6.
Ann Biomed Eng ; 2024 May 25.
Article in English | MEDLINE | ID: mdl-38796669

ABSTRACT

This study aimed to develop and validate a Computed Tomography (CT)/Magnetic Resonance Imaging (MRI)-compatible polymer oral retractor system to enable intraoperative image guidance for transoral robotic surgery (TORS). The retractor was designed based on standard-of-care metallic retractors and 3D (three-dimensional) printed with carbon fiber composite and nylon. The system was comprehensively evaluated in bench-top and cadaveric experiments in terms of its ability to enable intraoperative CT/MR images during TORS, functionality including surgical exposure and working volume, usability, compatibility with da Vinci surgical systems, feasibility for disinfection or sterilization, and robustness over an extended period of time. The polymer retractor system enabled the acquisition of high-resolution and artifact-free intraoperative CT/MR images during TORS. With an inter-incisive distance of 42.55 mm and a working volume of 200.09 cm3, it provided surgical exposure comparable to standard-of-care metallic retractors. The system proved intuitive and compatible with da Vinci S, Xi, and Single Port systems, enabling successful mock surgical tasks performed by surgeons and residents. The retractor components could be effectively disinfected or sterilized for clinical use without significant compromise in material strength, with STERRAD considered the optimal method. Throughout a 2 h mock procedure, the retractor system showed minimal displacements (<1.5 mm) due to surrounding tissue deformation, with insignificant device deformation. The 3D-printed polymer retractor system successfully enabled artifact-free intraoperative CT/MR imaging in TORS for the first time and demonstrated feasibility for clinical use. This breakthrough opens the door to surgical navigation with intraoperative image guidance in TORS, offering the potential to significantly improve surgical outcomes and patients' quality of life.

7.
Article in English | MEDLINE | ID: mdl-38752166

ABSTRACT

Laparoscopic and robotic surgery, as one type of minimally invasive surgery (MIS), has gained popularity due to the improved surgeon ergonomics, instrument precision, operative time, and postoperative recovery. Hyperspectral imaging (HSI) is an emerging medical imaging modality, which has proved useful for intraoperative image guidance. Snapshot hyperspectral cameras are ideal for intraoperative laparoscopic imaging because of their compact size and light weight, but low spatial resolution can be a limitation. In this work, we developed a dual-camera laparoscopic imaging system that consists of a high-resolution color camera and a snapshot hyperspectral camera, and we employed super-resolution reconstruction to fuse the images from both cameras to generate high-resolution hyperspectral images. The experimental results show that our method can significantly improve the resolution of hyperspectral images without compromising the image quality or spectral signatures. The proposed super-resolution reconstruction method is promising to promote the employment of high-speed hyperspectral imaging in laparoscopic surgery.

8.
Int J Comput Assist Radiol Surg ; 19(7): 1251-1258, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38789882

ABSTRACT

PURPOSE: Transoral robotic surgery (TORS) is a challenging procedure due to its small workspace and complex anatomy. Ultrasound (US) image guidance has the potential to improve surgical outcomes, but an appropriate method for US probe manipulation has not been defined. This study evaluates using an additional robotic (4th) arm on the da Vinci Surgical System to perform extracorporeal US scanning for image guidance in TORS. METHODS: A stereoscopic imaging system and da Vinci-compatible US probe attachment were developed to enable control of the extracorporeal US probe from the surgeon console. The prototype was compared to freehand US by nine operators in three tasks on a healthy volunteer: (1) identification of the common carotid artery, (2) carotid artery scanning, and (3) identification of the submandibular gland. Operator workload and user experience were evaluated using a questionnaire. RESULTS: The robotic US tasks took longer than freehand US tasks (2.09x longer; p = 0.001 ) and had higher operator workload (2.12x higher; p = 0.004 ). However, operator-rated performance was closer (avg robotic/avg freehand = 0.66; p = 0.017 ), and scanning performance measured by MRI-US average Hausdorff distance provided no statistically significant difference. CONCLUSION: Extracorporeal US scanning for intraoperative US image guidance is a convenient approach for providing the surgeon direct control over the US image plane during TORS, with little modification to the existing operating room workflow. Although more time-consuming and higher operator workload, several methods have been identified to address these limitations.


Subject(s)
Feasibility Studies , Robotic Surgical Procedures , Humans , Robotic Surgical Procedures/methods , Ultrasonography, Interventional/methods , Submandibular Gland/surgery , Submandibular Gland/diagnostic imaging , Equipment Design , Surgery, Computer-Assisted/methods
9.
Cureus ; 16(4): e57717, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38711731

ABSTRACT

Augmented reality (AR) is an emerging technology that can display three-dimensional patient anatomy in the surgeons' field of view. The use of this technology has grown considerably for both presurgical and intraoperative guidance. A patient diagnosed with breast cancer started to experience numbness in the left hand, which progressed to weakness in the left hand and arm. An MRI was performed demonstrating a 2.9 cm X 1.8 cm lesion with extensive surrounding edema in the posterior fronto-parietal lobes. Surgery was recommended for presumed metastatic disease. Preoperatively, an AR system and Brainlab navigation were registered to the patient. AR, traditional navigation, and ultrasound were all used to localize the lesion and determine the craniotomy site and size. The tumor was removed along the direction of the lesion. Intraoperatively, we used AR to reexamine the tumor details and could appreciate that we had to redirect our surgical trajectory anteriorly and laterally in order to follow along the main axis of the tumor. In doing this, we were able to more confidently remain with the tumor, which by this time was poorly defined by 2D navigation and by direct vision. Postoperative MRI confirmed gross total removal of the tumor. The patient had an uneventful postoperative course with resolution of preoperative symptoms and the final surgical pathology was grade 4 glioblastoma. Here, we describe the valuable use of AR for the resection of a glioma. The system has a seamless registration process and provides the surgeon with a unique view of 3D anatomy overlaid onto the patient's head. This exciting technology can add tremendous value to complex cranial surgeries.

10.
Cancers (Basel) ; 16(10)2024 May 18.
Article in English | MEDLINE | ID: mdl-38792000

ABSTRACT

Magnetic resonance imaging (MRI) can facilitate accurate organ delineation and optimal dose distributions in high-dose-rate (HDR) MRI-Assisted Radiosurgery (MARS). Its use for this purpose has been limited by the lack of positive-contrast MRI markers that can clearly delineate the lumen of the HDR applicator and precisely show the path of the HDR source on T1- and T2-weighted MRI sequences. We investigated a novel MRI positive-contrast HDR brachytherapy or interventional radiotherapy line marker, C4:S, consisting of C4 (visible on T1-weighted images) complexed with saline. Longitudinal relaxation time (T1) and transverse relaxation time (T2) for C4:S were measured on a 1.5 T MRI scanner. High-density polyethylene (HDPE) tubing filled with C4:S as an HDR brachytherapy line marker was tested for visibility on T1- and T2-weighted MRI sequences in a tissue-equivalent female ultrasound training pelvis phantom. Relaxivity measurements indicated that C4:S solution had good T1-weighted contrast (relative to oil [fat] signal intensity) and good T2-weighted contrast (relative to water signal intensity) at both room temperature (relaxivity ratio > 1; r2/r1 = 1.43) and body temperature (relaxivity ratio > 1; r2/r1 = 1.38). These measurements were verified by the positive visualization of the C4:S (C4/saline 50:50) HDPE tube HDR brachytherapy line marker on both T1- and T2-weighted MRI sequences. Orientation did not affect the relaxivity of the C4:S contrast solution. C4:S encapsulated in HDPE tubing can be visualized as a positive line marker on both T1- and T2-weighted MRI sequences. MRI-guided HDR planning may be possible with these novel line markers for HDR MARS for several types of cancer.

11.
J Clin Med ; 13(7)2024 Apr 01.
Article in English | MEDLINE | ID: mdl-38610801

ABSTRACT

Intraoperative navigation is critical during spine surgery to ensure accurate instrumentation placement. From the early era of fluoroscopy to the current advancement in robotics, spinal navigation has continued to evolve. By understanding the variations in system protocols and their respective usage in the operating room, the surgeon can use and maximize the potential of various image guidance options more effectively. At the same time, maintaining navigation accuracy throughout the procedure is of the utmost importance, which can be confirmed intraoperatively by using an internal fiducial marker, as demonstrated herein. This technology can reduce the need for revision surgeries, minimize postoperative complications, and enhance the overall efficiency of operating rooms.

12.
Cancers (Basel) ; 16(7)2024 Mar 22.
Article in English | MEDLINE | ID: mdl-38610923

ABSTRACT

To develop ultrasound-guided radiotherapy, we proposed an assistant structure with embedded markers along with a novel alternative method, the Aligned Peak Response (APR) method, to alter the conventional delay-and-sum (DAS) beamformer for reconstructing ultrasound images obtained from a flexible array. We simulated imaging targets in Field-II using point target phantoms with point targets at different locations. In the experimental phantom ultrasound images, image RF data were acquired with a flexible transducer with in-house assistant structures embedded with needle targets for testing the accuracy of the APR method. The lateral full width at half maximum (FWHM) values of the objective point target (OPT) in ground truth ultrasound images, APR-delayed ultrasound images with a flat shape, and images acquired with curved transducer radii of 500 mm and 700 mm were 3.96 mm, 4.95 mm, 4.96 mm, and 4.95 mm. The corresponding axial FWHM values were 1.52 mm, 4.08 mm, 5.84 mm, and 5.92 mm, respectively. These results demonstrate that the proposed assistant structure and the APR method have the potential to construct accurate delay curves without external shape sensing, thereby enabling a flexible ultrasound array for tracking pancreatic tumor targets in real time for radiotherapy.

13.
Orbit ; : 1-10, 2024 Apr 30.
Article in English | MEDLINE | ID: mdl-38687963

ABSTRACT

PURPOSE: The posterior orbit is a confined space, harbouring neurovascular structures, frequently distorted by tumours. Image-guided navigation (IGN) has the potential to allow accurate localisation of these lesions and structures, reducing collateral damage whilst achieving surgical objectives. METHODS: We assessed the feasibility, effectiveness and safety of using an electromagnetic IGN for posterior orbital tumour surgery via a comparative cohort study. Outcomes from cases performed with IGN were compared with a retrospective cohort of similar cases performed without IGN, presenting a descriptive and statistical comparative analysis. RESULTS: Both groups were similar in mean age, gender and tumour characteristics. IGN set-up and registration were consistently achieved without significant workflow disruption. In the IGN group, fewer lateral orbitotomies (6.7% IGN, 46% non-IGN), and more transcutaneous lid and transconjunctival incisions (93% IGN, 53% non-IGN) were performed (p = .009). The surgical objective was achieved in 100% of IGN cases, with no need for revision surgery (vs 23% revision surgery in non-IGN, p = .005). There was no statistically significant difference in surgical complications. CONCLUSION: The use of IGN was feasible and integrated into the orbital surgery workflow to achieve surgical objectives more consistently and allowed the use of minimal access approaches. Future multicentre comparative studies are needed to explore the potential of this technology further.

14.
Korean J Radiol ; 25(5): 438-448, 2024 May.
Article in English | MEDLINE | ID: mdl-38685734

ABSTRACT

OBJECTIVE: To evaluate the therapeutic outcomes of no-touch radiofrequency ablation (NT-RFA) using twin cooled wet (TCW) electrodes in patients experiencing recurrent hepatocellular carcinoma (HCC) after undergoing locoregional treatments. MATERIALS AND METHODS: We conducted a prospective, single-arm study of NT-RFA involving 102 patients, with a total of 112 recurrent HCCs (each ≤ 3 cm). NT-RFA with TCW electrodes was implemented under the guidance of ultrasonography (US)-MR/CT fusion imaging. If NT-RFA application proved technically challenging, conversion to conventional tumor puncture RFA was permitted. The primary metric for evaluation was the mid-term cumulative incidence of local tumor progression (LTP) observed post-RFA. Cumulative LTP rates were estimated using the Kaplan-Meier method. Multivariable Cox proportional hazard regression was used to explore factors associated with LTP. Considering conversion cases from NT-RFA to conventional RFA, intention-to-treat (ITT; including all patients) and per-protocol (PP; including patients not requiring conversion to conventional RFA alone) analyses were performed. RESULTS: Conversion from NT-RFA to conventional RFA was necessary for 24 (21.4%) out of 112 tumors. Successful treatment was noted in 111 (99.1%) out of them. No major complications were reported among the patients. According to ITT analysis, the estimated cumulative incidences of LTP were 1.9%, 6.0%, and 6.0% at 1, 2, and 3 years post-RFA, respectively. In PP analysis, the cumulative incidence of LTP was 0.0%, 1.3%, and 1.3% at 1, 2, and 3 years, respectively. The number of previous locoregional HCC treatments (adjusted hazard ratio [aHR], 1.265 per 1 treatment increase; P = 0.004), total bilirubin (aHR, 7.477 per 1 mg/dL increase; P = 0.012), and safety margin ≤ 5 mm (aHR, 9.029; P = 0.016) were independently associated with LTP in ITT analysis. CONCLUSION: NT-RFA using TCW electrodes is a safe and effective treatment for recurrent HCC, with 6.0% (ITT analysis) and 1.3% (PP analysis) cumulative incidence of LTP at 2 and 3-year follow-ups.


Subject(s)
Carcinoma, Hepatocellular , Electrodes , Liver Neoplasms , Neoplasm Recurrence, Local , Radiofrequency Ablation , Humans , Liver Neoplasms/surgery , Liver Neoplasms/diagnostic imaging , Carcinoma, Hepatocellular/surgery , Carcinoma, Hepatocellular/diagnostic imaging , Male , Female , Middle Aged , Prospective Studies , Radiofrequency Ablation/methods , Aged , Treatment Outcome , Catheter Ablation/methods
15.
Arthroplast Today ; 26: 101337, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38497084

ABSTRACT

Avascular necrosis of the femoral head is a debilitating condition that can lead to femoral head collapse. Core decompression with adjuvant cellular therapies, such as bone marrow aspirate concentrate, delays disease progression and improves outcomes. However, inconsistent results in the literature may be due to limitations in surgical technique and difficulty in targeting the necrotic lesions. Here, we present a surgical technique utilizing computed tomography-based three-dimensional modeling and instrument tracking to guide the therapy to the center of the lesion. This method minimizes the number of attempts to reach the lesion and confirms the three-dimensional positioning of the instrumentation within the lesion. Our technique may improve the outcomes of core decompression and adjuvant therapy and prevent or delay hip collapse in patients with femoral head avascular necrosis.

16.
J Med Imaging (Bellingham) ; 11(2): 025001, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38445222

ABSTRACT

Purpose: To study the difference between rigid registration and nonrigid registration using two forms of digitization (contact and noncontact) in human in vivo liver surgery. Approach: A Conoprobe device attachment and sterilization process was developed to enable prospective noncontact intraoperative acquisition of organ surface data in the operating room (OR). The noncontact Conoprobe digitization method was compared against stylus-based acquisition in the context of image-to-physical registration for image-guided surgical navigation. Data from n=10 patients undergoing liver resection were analyzed under an Institutional Review Board-approved study at Memorial Sloan Kettering Cancer Center. Organ surface coverage of each surface acquisition method was compared. Registration accuracies resulting from the acquisition techniques were compared for (1) rigid registration method (RRM), (2) model-based nonrigid registration method (NRM) using surface data only, and (3) NRM with one subsurface feature (vena cava) from tracked intraoperative ultrasound (NRM-VC). Novel vessel centerline and tumor targets were segmented and compared to their registered preoperative counterparts for accuracy validation. Results: Surface data coverage collected by stylus and Conoprobe were 24.6%±6.4% and 19.6%±5.0%, respectively. The average difference between stylus data and Conoprobe data using NRM was -1.05 mm and using NRM-VC was -1.42 mm, indicating the registrations to Conoprobe data performed worse than to stylus data with both NRM approaches. However, using the stylus and Conoprobe acquisition methods led to significant improvement of NRM-VC over RRM by average differences of 4.48 and 3.66 mm, respectively. Conclusion: The first use of a sterile-field amenable Conoprobe surface acquisition strategy in the OR is reported for open liver surgery. Under clinical conditions, the nonrigid registration significantly outperformed standard-of-care rigid registration, and acquisition by contact-based stylus and noncontact-based Conoprobe produced similar registration results. The accuracy benefits of noncontact surface acquisition with a Conoprobe are likely obscured by inferior data coverage and intrinsic noise within acquisition systems.

17.
Cancers (Basel) ; 16(6)2024 Mar 18.
Article in English | MEDLINE | ID: mdl-38539527

ABSTRACT

With the rapidly evolving field of image-guided tumor ablation, there is an increasing demand and need for tools to optimize treatment success. Known factors affecting the success of (non-)thermal liver ablation procedures are the ability to optimize tumor and surrounding critical structure visualization, ablation applicator targeting, and ablation zone confirmation. A recent study showed superior local tumor progression-free survival and local control outcomes when using transcatheter computed tomography hepatic angiography (CTHA) guidance in percutaneous liver ablation procedures. This pictorial review provides eight clinical cases from three institutions, MD Anderson (Houston, TX, USA), Gustave Roussy (Paris, France), and Amsterdam UMC (Amsterdam, The Netherlands), with the intent to demonstrate the added value of real-time CTHA guided tumor ablation for primary liver tumors and liver-only metastatic disease. The clinical illustrations highlight the ability to improve the detectability of the initial target liver tumor(s) and identify surrounding critical vascular structures, detect 'vanished' and/or additional tumors intraprocedurally, differentiate local tumor progression from non-enhancing scar tissue, and promptly detect and respond to iatrogenic hemorrhagic events. Although at the cost of adding a minor but safe intervention, CTHA-guided liver tumor ablation minimizes complications of the actual ablation procedure, reduces the number of repeat ablations, and improves the oncological outcome of patients with liver malignancies. Therefore, we recommend adopting CTHA as a potential quality-improving guiding method within the (inter)national standards of practice.

18.
Cureus ; 16(1): e52383, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38371146

ABSTRACT

Image guidance technologies can significantly improve the accuracy and safety of intracranial catheter insertions. Augmented reality (AR) allows surgeons to visualize 3D information overlaid onto a patient's head. As such, AR has emerged as a novel image guidance technology that offers unique advantages when navigating intracranial targets. A 71-year-old woman with a history of brain metastasis from breast cancer and prior resection surgery and chemotherapy presented with altered mental status and generalized weakness worse on her left side. Magnetic resonance imaging (MRI) demonstrated right frontotemporoparietal edema with a contrast-enhancing mass. MR perfusion confirmed an active tumor with an enlarging right temporal pole cyst. A cyst aspiration was performed via Ommaya reservoir placement. Neuro-navigation (BrainLab, Munich, Germany) and AR navigation were used to plan the trajectory from the temporal gyrus to the cyst. Post-operative computed tomography (CT) demonstrated good placement of the reservoir, reconstitution of the temporal horn of the lateral ventricle with decreased external mass effect, and no areas of hemorrhage. AR has tremendous potential in the field of neurosurgery for improving the accuracy and safety of procedures. This case demonstrates an encouraging application of AR and can serve as an example to drive expanded clinical use of this technology.

19.
Neurosurg Clin N Am ; 35(2): 199-205, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38423735

ABSTRACT

A historical overview of the evolution of anterolateral approaches to the lumber spine and associated patient outcomes is presented. In addition, the modern incorporation of new technologies is discussed, including interbody cages, intraoperative image guidance, robotics, augmented reality, and machine learning, which have significantly improved the spine surgery safety and efficacy profile. Current challenges and future directions are also covered, emphasizing the need for further research and development, particularly in robotic assistance and machine learning algorithms.


Subject(s)
Lumbar Vertebrae , Machine Learning , Humans , Lumbar Vertebrae/surgery
20.
Front Neurosci ; 18: 1310282, 2024.
Article in English | MEDLINE | ID: mdl-38348134

ABSTRACT

The review begins with an overview of the fundamental principles/physics underlying light, fluorescence, and other light-matter interactions in biological tissues. It then focuses on 5-aminolevulinic acid (5-ALA)-induced protoporphyrin IX (PpIX) fluorescence spectroscopy methods used in neurosurgery (e.g., intensity, time-resolved) and in so doing, describe their specific features (e.g., hardware requirements, main processing methods) as well as their strengths and limitations. Finally, we review current clinical applications and future directions of 5-ALA-induced protoporphyrin IX (PpIX) fluorescence spectroscopy in neurosurgery.

SELECTION OF CITATIONS
SEARCH DETAIL
...