Results 1 - 20 de 465
Filter
1.
J Pediatr Urol ; 2024 Jun 12.
Article in English | MEDLINE | ID: mdl-38987105

ABSTRACT

INTRODUCTION: Lost objects and equipment malfunctions during robotic and laparoscopic cases can lead to an increase in operating time and potential risk to the patient. The literature on the management of foreign bodies during pediatric robotic-assisted surgery is limited. The purpose of the video is to review proper instrument handling to prevent loss of an object and to propose our technique for retrieving lost objects through two pediatric case examples. MATERIALS AND METHODS: The first case is a robotic-assisted laparoscopic left pyeloplasty in a 6-week-old male with congenital uteropelvic junction obstruction during which a needle was lost. In the video, we describe our techniques for safe needle passage, proper suturing technique, and recovering a lost needle. The second case is a robotic-assisted right upper pole heminephrectomy in a 14-month-old female with a duplicated renal collecting system and hydroureteronephrosis. We present the management of a rare case during which a harmonic scalpel jaw malfunctioned leading to a lost foreign body. We describe our technique for retrieving the lost fragment. RESULTS: All objects were safely removed, and patients were discharged post-op day one without complication. CONCLUSION: Our video presents two case examples of foreign bodies lost during pediatric robotic surgeries and approaches to manage each of these incidents.

3.
Europace ; 26(6)2024 Jun 03.
Article in English | MEDLINE | ID: mdl-38861398

ABSTRACT

AIMS: Subcutaneous implantable cardioverter-defibrillators (S-ICDs) offer potentially distinct advantages over transvenous defibrillator systems. Recent randomized trials showed significantly lower lead failure rates than transvenous ICD. Still, S-ICDs remain associated with the risk of inappropriate shocks (IAS). While previous studies have reported varying causes of IAS, this study explores a rare cause of IAS, referred to as 'sense-B-noise.' It was recently described in case series, but its incidence has not been studied in a large cohort of S-ICD patients. METHODS AND RESULTS: We retrospectively reviewed data from patients implanted with S-ICD models 1010, A209, and A219 between October 2009 and July 2023 across nine centres in Europe and the USA. The analysis concentrated on determining the incidence and understanding the implications of sense-B-noise events. Sense-B-noise represents a rare manifestation of distinct electrogram abnormalities within the primary and alternate sensing vectors. Data were collected from medical records, device telemetry, and manufacturer reports for investigation. This registry is registered on clinicaltrials.gov (NCT05713708). Subcutaneous implantable cardioverter-defibrillator devices of the 1158 patients were analysed. The median follow-up time for all patients was 46 (IQR 23-64) months. In 107 patients (9.2%) ≥1 IAS was observed during follow-up. Sense-B-noise failure was diagnosed in six (0.5 and 5.6% of all IAS) patients, in all patients, the diagnosis was made after an IAS episode. Median lead dwell time in the affected patients was 23 (2-70) months. To resolve the sense-B-noise defect, in three patients reprogramming to the secondary vector was undertaken, and two patients underwent system removal with subsequent S-ICD reimplantation due to low amplitude in the secondary vector. In one patient, the secondary vector was initially programmed, and subsequently, an S-ICD system exchange was performed due to T-wave-oversensing IAS episodes. CONCLUSION: This multicentre analysis' findings shed light on a rare but clinically highly significant adverse event in S-ICD therapy. To our knowledge, we provide the first systematic multicentre analysis investigating the incidence of sense-B-noise. Due to being difficult to diagnose and limited options for resolution, management of sense-B-noise is challenging. Complete system exchange may be the only option for some patients. Educating healthcare providers involved in S-ICD patient care is crucial for ensuring accurate diagnosis and effective management of sense-B-noise issues.


Subject(s)
Defibrillators, Implantable , Electric Countershock , Registries , Humans , Male , Retrospective Studies , Female , Middle Aged , Incidence , Electric Countershock/instrumentation , Electric Countershock/adverse effects , Aged , Europe/epidemiology , Equipment Failure/statistics & numerical data , United States/epidemiology , Risk Factors
4.
Neurosurg Focus ; 56(6): E12, 2024 06.
Article in English | MEDLINE | ID: mdl-38823042

ABSTRACT

OBJECTIVE: The aim of this study was 1) to describe the rate of intrathecal baclofen (ITB)-associated complications at a large tertiary center, and 2) to evaluate the impact of patient-related factors on the likelihood of developing such complications. METHODS: A retrospective single-center study was carried out. A total of 301 eligible patients were included in the analysis. Univariate regression models were used to evaluate the impact of age, sex, diagnosis, ambulation status, modified Ashworth scale score, body mass index, diabetes status, and pain level on the likelihood of developing a device-related infection, pump malfunction, catheter malfunction, and other clinically significant complications. RESULTS: Overall, 27% of patients experienced an ITB-related complication. The most common complications included infection (6%, 18/301), pump malfunction (7.3%, 22/301), and catheter malfunction (14%, 42/301). The univariate analyses revealed that the patient's ambulatory status had a significant impact on the likelihood of developing a catheter-related malfunction. Furthermore, a trend toward significance was identified between patients' preoperative body mass index and device-related infection. Finally, the risk of suffering any ITB-related complications was statistically correlated with the number of years that had passed since the initial pump implantation. CONCLUSIONS: The authors' analysis reveals a previously underrecognized association between ambulatory status at the time of ITB pump implantation and the incidence of catheter-related complications, and confirms the impact of time since surgery on the risk of developing any ITB-related complication. The patient's age, sex, diagnosis, diabetes status, or pain level at baseline were not associated with the risk of complications. Collectively, these insights contribute novel information to the existing literature, providing practical value for physicians in guiding patient selection for ITB therapy.


Subject(s)
Baclofen , Infusion Pumps, Implantable , Injections, Spinal , Muscle Relaxants, Central , Humans , Baclofen/administration & dosage , Baclofen/adverse effects , Male , Female , Middle Aged , Retrospective Studies , Adult , Risk Factors , Infusion Pumps, Implantable/adverse effects , Muscle Relaxants, Central/administration & dosage , Muscle Relaxants, Central/adverse effects , Injections, Spinal/adverse effects , Aged , Young Adult , Muscle Spasticity/drug therapy , Equipment Failure/statistics & numerical data , Adolescent
5.
Neurosurg Focus ; 56(6): E11, 2024 06.
Article in English | MEDLINE | ID: mdl-38823047

ABSTRACT

OBJECTIVE: Intrathecal baclofen (ITB) pumps are commonly used in pediatric patients with cerebral palsy (CP) and medically refractory spasticity. However, catheter malfunction and associated risk factors are not well understood. The aim of this study was to examine potential risk factors for spinal catheter malfunction and characterize postoperative follow-up to understand the clinical consequences. METHODS: Patients who received ITB pump replacement or revision at Boston Children's Hospital between 2010 and 2023 were retrospectively reviewed. The spinal catheter revision cohort (SCRC) included patients whose spinal catheter was occluded requiring lumbar catheter revision. The second cohort included abdominal pump replacements only (APRC). Between-group comparisons and multivariable regression identified factors associated with catheter revision and postoperative outcomes. RESULTS: Forty-one (33.6%) patients underwent spinal catheter revision and were compared with 81 patients (66.4%) who underwent abdominal pump replacement only. Younger age at surgery and an elevated preoperative lower-extremity modified Ashworth scale grade were associated with spinal catheter revision (p < 0.05). Catheter model type, tip location, and history of spinal fusion were not associated with obstruction. Postoperatively, SCRC patients experienced a higher rate of infection (17.1%) relative to APRC patients (0%) within 30 days from their ITB pump replacement procedure (p < 0.05) and greater likelihood of subsequent ITB system removal compared with the APRC (24.4% vs 7.4%, p < 0.05). Although not differing preoperatively, SCRC patients had lower postoperative ITB doses when compared with the APRC group (median dose 143 vs 350 µg/day, p < 0.05) at hospital discharge and remained statistically different at the 6-month and 1-year follow-ups (p < 0.05). There were no postoperative differences in baclofen overdose, withdrawal, or median number of hospital readmissions within 30 days. Overall, 31.7% of spinal catheter revisions were unanticipated by the clinical team at time of surgery. CONCLUSIONS: Younger age at surgery and increased preoperative lower-extremity tone may be risk factors for catheter obstruction, resulting in a higher rate of postoperative infection and subsequent ITB pump removal compared with pump replacement alone. Spinal catheter occlusion can complicate revision or replacement procedures, especially when unanticipated. Routine clinical assessment may be inadequate for diagnosing insidious catheter malfunction. Catheter occlusion deserves further study, and routine assessment of catheter patency may be warranted to prevent suboptimal tone therapy.


Subject(s)
Baclofen , Cerebral Palsy , Infusion Pumps, Implantable , Muscle Relaxants, Central , Humans , Baclofen/administration & dosage , Baclofen/adverse effects , Male , Female , Child , Infusion Pumps, Implantable/adverse effects , Risk Factors , Muscle Relaxants, Central/administration & dosage , Retrospective Studies , Adolescent , Cerebral Palsy/surgery , Cerebral Palsy/complications , Child, Preschool , Muscle Spasticity/drug therapy , Muscle Spasticity/etiology , Muscle Spasticity/surgery , Reoperation/methods , Injections, Spinal/methods , Treatment Outcome , Postoperative Complications/etiology , Equipment Failure , Cohort Studies
6.
Europace ; 26(7)2024 Jul 02.
Article in English | MEDLINE | ID: mdl-38885309

ABSTRACT

AIMS: Subcutaneous implantable cardioverter-defibrillators (S-ICDs) have become established in preventing sudden cardiac death, with some advantages over transvenous defibrillator systems, including a lower incidence of lead failures. Despite technological advancements, S-ICD carriers may suffer from significant complications, such as premature battery depletion (PBD), that led to an advisory for nearly 40 000 patients. This multicentre study evaluated the incidence of PBD in a large set of S-ICD patients. METHODS AND RESULTS: Data from patients implanted with S-ICD models A209 and A219 between October 2012 and July 2023 across nine centres in Europe and the USA were reviewed. Incidence and implications of PBD, defined as clinically observed sudden drop in battery longevity, were analysed and compared to PBD with the definition of battery depletion within 60 months. Prospectively collected clinical data were obtained retrospectively from medical records, device telemetry, and manufacturer reports. This registry is listed on ClinicalTrials.gov (NCT05713708). Of the 1112 S-ICD devices analysed, 547 (49.2%) were equipped with a potentially affected capacitor linked to PBD occurrence, currently under Food and Drug Administration advisory. The median follow-up time for all patients was 46 [inter-quartile range (IQR) 24-63] months. Clinically suspected PBD was observed in 159 (29.1%) of cases, with a median time to generator removal or replacement of 65 (IQR 55-72) months, indicative of significant deviations from expected battery lifespan. Manufacturer confirmation of PBD was made in 91.7% of devices returned for analysis. No cases of PBD were observed in devices that were not under advisory. CONCLUSION: This manufacturer-independent analysis highlights a notable incidence of PBD in patients equipped with S-ICD models under advisory, and the rate of PBD in this study corresponds to the rate currently estimated by the manufacturer. To the best of our knowledge, this provides the largest contemporary peer-reviewed study cohort investigating the actual incidence of PBD in S-ICD patients. These findings emphasize the importance of post-market registries in collaboration between clinicians and the manufacturer to optimize safety and efficacy in S-ICD treatment.


Subject(s)
Defibrillators, Implantable , Electric Power Supplies , Registries , Humans , Male , Female , Middle Aged , Retrospective Studies , Aged , United States/epidemiology , Death, Sudden, Cardiac/prevention & control , Death, Sudden, Cardiac/epidemiology , Europe/epidemiology , Electric Countershock/instrumentation , Electric Countershock/adverse effects , Equipment Failure/statistics & numerical data , Time Factors , Equipment Failure Analysis/statistics & numerical data , Adult
7.
Ren Fail ; 46(2): 2369695, 2024 Dec.
Article in English | MEDLINE | ID: mdl-38938162

ABSTRACT

BACKGROUND: This study aims to establish a simplified and effective animal model of catheter malfunction caused by omental wrapped using negative pressure suction. METHOD: The peritoneal dialysis catheter outlet was linked to a negative-pressure (0-75mmHg) suction pump to intensify the negative pressure. Different negative pressures were tested for model construction in vitro. In vivo, a model of peritoneal catheter malfunction caused by omental wrapped was constructed in five beagles after catheter placement. Catheter drainage conditions and related complications were monitored before and after the model establishment. RESULTS: In the vitro experiment, the overall success rate of constructed models was 90% (36/40). The total malfunction rate was higher in 62.5 mmHg (10/10) and 75 mmHg (10/10) than in 12.5 mmHg (8/10) and 37.5 mmHg (8/10). The outflow velocity of dialysate at 62.5 mmHg was significantly lower than that at 12.5 mmHg and 37.5 mmHg, without a statistically significant difference compared to 75 mmHg. In the in vivo experiment, catheter outflow velocity increased, and residual fluid volume decreased after omental wrapped (99.6 ± 6.7 ml/min vs. 32.6 ± 4.6 ml/min at initial five minutes, p < 0.0001; 69.2 ± 16.3 ml vs. 581.0 ± 109.4 ml, p < 0.001). And the outflow velocity was finally below 2 ml/min. No severe related complications (such as infection, organ damage, or bleeding) were observed through laparoscopic examination and dialysate tests seven days post-operation. CONCLUSION: Utilizing negative pressure suction to increase negative pressure around catheter tip is a simple, safe, and effective method for establishing an animal model of omental wrapped leading to catheter malfunction.


Subject(s)
Equipment Failure , Omentum , Peritoneal Dialysis , Animals , Dogs , Suction/instrumentation , Peritoneal Dialysis/instrumentation , Peritoneal Dialysis/adverse effects , Catheters, Indwelling/adverse effects , Disease Models, Animal , Male , Models, Animal
8.
J Vasc Access ; : 11297298241254561, 2024 Jun 05.
Article in English | MEDLINE | ID: mdl-38836580

ABSTRACT

Fibroblastic sleeve is a common pathophysiological phenomenon characterized by the formation of a mixed fibrous-collagen tissue encasing the outside of venous access devices. Although it nearly always presents asymptomatically, this catheter-related complication represents one of the leading culprits of venous catheters malfunction. Several techniques have been described for the management of dysfunctional catheters secondary to fibroblastic sleeve, including medical therapy, catheter exchange, balloon angioplasty, and percutaneous stripping. However, there is no common consensus for the treatment management in patients who present contraindications to surgical port removal. This report illustrates the case of a port catheter malfunction due to a fibroblastic sleeve in an oncological patient with a high risk of bleeding. This was effectively treated with a minimally invasive stripping technique using an off-label device for mechanical thrombectomy, namely the ClotTriever system (Inari Medical, Irvine, CA).

9.
Neurosurg Rev ; 47(1): 269, 2024 Jun 12.
Article in English | MEDLINE | ID: mdl-38864925

ABSTRACT

Ventriculoperitoneal shunt surgery was developed to manage excessive cerebrospinal fluid (CSF) in the brain's ventricles and is considered a mainstream treatment. Despite the development of the shunt device system, various complications still occur. In this study, we reported 307 cases and a long-term follow-up of at least five years of adult patients who underwent VP shunt surgery and analyzed various factors that may affect revision surgery. A retrospective study was conducted at Asan Medical Center, Korea, a tertiary medical center. We reviewed 307 cases from January 2012 to December 2018. The patients' neurological status, predisposing medical conditions, laboratory findings, and other operation-related factors were reviewed using electrical medical records. The normal function group comprised 272 cases (88.6%), and the overall incidence of revision group comprised 35 cases (11.4%). Of the 35 revision surgery cases, 30 (85.71%) were due to shunt malfunctions, such as obstruction, overdrainage, and valve-related errors while 5 (14.29%) were due to shunt infection. Patient demographics, mental status, and operation time did not influence revision as risk factors. Serum laboratory findings showed no statistical difference between the two groups. The white blood cell (WBC) count in the CSF profile differed significantly between the two groups. The Hakim Programmable valve (Codman, USA) is mainly used in our center. In addition, various shunt systems were used, including Strata Regulatory valve (Medtronic, USA), proGAV (Aesculap, USA), and Accu-Flo (Codman, USA). This study analyzed the factors affecting long-term outcomes. Based on these findings, efforts are needed to achieve more favorable outcomes in the future.


Subject(s)
Hydrocephalus , Ventriculoperitoneal Shunt , Humans , Ventriculoperitoneal Shunt/adverse effects , Male , Female , Middle Aged , Risk Factors , Adult , Retrospective Studies , Incidence , Aged , Follow-Up Studies , Hydrocephalus/surgery , Reoperation , Postoperative Complications/epidemiology , Equipment Failure , Young Adult
10.
Article in English | MEDLINE | ID: mdl-38923693

ABSTRACT

INTRODUCTION: Pacemaker-mediated tachycardia is a known arrhythmia in patients with dual chamber pacemakers and defibrillators and intact ventriculoatrial (VA) conduction. We report a case of pacemaker-mediated reentrant arrhythmia (PMRA) in a patient with an atrioventricular (AV) synchronous leadless pacemaker. METHODS AND RESULTS: A 91-year-old female presented with 2:1 AV conduction and received an AV synchronous leadless pacemaker. She had atrial mechanical sense-ventricular paced beats between heart rates of 80-100 bpm more than 80% of the time. She was found to have a new cardiomyopathy and was referred for placement of biventricular pacemaker. At the time of device implantation, her electrocardiogram showed ventricular pacing with a short RP interval and superiorly directed P waves. Changes in the ventricular pacing rate resulted in changes in the atrial rate. Following device placement, her heart rate decreased to the lower rate limit of her pacemaker. The atrial mechanical sense impulse most likely was generated by a retrograde conducted P wave resulting in near incessant PMRA. CONCLUSION: PMRA may occur in patients who receive an AV synchronous leadless pacemaker with intact VA conduction and sinoatrial node dysfunction. Due to the lower rates of PMRA, this arrhythmia may be underrecognized. Interventions for and implications of PMRA need further investigation.

11.
Ergonomics ; 67(6): 866-880, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38770836

ABSTRACT

By conducting a mixed-design experiment using simplified accident handling tasks performed by two-person teams, this study examined the effects of automation function and condition (before, during, and after malfunction) on human performance. Five different and non-overlapping functions related to human information processing model were considered and their malfunctions were set in a first-failure way. The results showed that while the automation malfunction impaired task performance, the performance degradation for information analysis was more severe than response planning. Contrary to other functions, the situation awareness for response planning and response implementation tended to increase during malfunctioning and decrease after. In addition, decreased task performance reduced trust in automation, and malfunctions in earlier stages of information processing resulted in lower trust. Suggestions provided for the design and training related to automation emphasise the importance of high-level cognitive support and the benefit of involving automation error handling in training.


The effects of automation function and malfunction on human performance are important for design and training. The experimental results in this study revealed the significance of high-level cognitive support. Also, introducing automation error handling in training can be helpful in improving situation awareness of the teams.


Subject(s)
Automation , Task Performance and Analysis , Humans , Male , Female , Adult , Young Adult , Man-Machine Systems , Trust , Awareness
12.
Int J Mol Sci ; 25(10)2024 May 10.
Article in English | MEDLINE | ID: mdl-38791244

ABSTRACT

Cervical artery dissection (CeAD) is the primary cause of ischemic stroke in young adults. Monogenic heritable connective tissue diseases account for fewer than 5% of cases of CeAD. The remaining sporadic cases have known risk factors. The clinical, radiological, and histological characteristics of systemic vasculopathy and undifferentiated connective tissue dysplasia are present in up to 70% of individuals with sporadic CeAD. Genome-wide association studies identified CeAD-associated genetic variants in the non-coding genomic regions that may impact the gene transcription and RNA processing. However, global gene expression profile analysis has not yet been carried out for CeAD patients. We conducted bulk RNA sequencing and differential gene expression analysis to investigate the expression profile of protein-coding genes in the peripheral blood of 19 CeAD patients and 18 healthy volunteers. This was followed by functional annotation, heatmap clustering, reports on gene-disease associations and protein-protein interactions, as well as gene set enrichment analysis. We found potential correlations between CeAD and the dysregulation of genes linked to nucleolar stress, senescence-associated secretory phenotype, mitochondrial malfunction, and epithelial-mesenchymal plasticity.


Subject(s)
Gene Expression Profiling , Humans , Male , Female , Gene Expression Profiling/methods , Adult , Middle Aged , Genome-Wide Association Study , Transcriptome/genetics , Vertebral Artery Dissection/genetics , Case-Control Studies
13.
Ren Fail ; 46(1): 2353351, 2024 Dec.
Article in English | MEDLINE | ID: mdl-38757707

ABSTRACT

OBJECTIVE: To investigate the feasibility and efficacy of combining ultrasound-guided sharp needle technique with percutaneous transluminal angioplasty (PTA) for treating outflow stenosis or dysfunction in arteriovenous fistula (AVF) among hemodialysis patients. METHODS: From October 2021 to March 2023, patients with occluded or malfunctional fistula veins not amenable to regularly angioplasty were retrospectively enrolled in the study. They underwent ultrasound-guided sharp needle intervention followed by PTA. Data on the location and length between the two veins, technical success, clinical outcomes, and complications were collected. Patency rates post-angioplasty were calculated through Kaplan-Meier analysis. RESULTS: A total of 23 patients were included. The mean length of the reconstructed extraluminal segment was 3.18 cm. The sharp needle opening was performed on the basilic vein (60.9%), brachial vein (26.1%), or upper arm cephalic vein (13%) to create outflow channels. Postoperatively, all cases presented with mild subcutaneous hematomas around the tunneling site and minor diffuse bleeding. The immediate patency rate for the internal fistulas was 100%, with 3-month, 6-month, and 12-month patency rates at 91.3%, 78.3%, and 43.5%, respectively. CONCLUSION: Sharp needle technology merged with PTA presents an effective and secure minimally invasive method for reconstructing the outflow tract, offering a new solution for recanalizing high-pressure or occluded fistulas.


Subject(s)
Arteriovenous Shunt, Surgical , Renal Dialysis , Ultrasonography, Interventional , Vascular Patency , Humans , Female , Male , Arteriovenous Shunt, Surgical/adverse effects , Arteriovenous Shunt, Surgical/methods , Middle Aged , Renal Dialysis/methods , Retrospective Studies , Aged , Adult , Needles , Angioplasty/methods , Graft Occlusion, Vascular/etiology , Feasibility Studies , Treatment Outcome
14.
J Neurosurg Pediatr ; 34(1): 75-83, 2024 Jul 01.
Article in English | MEDLINE | ID: mdl-38579347

ABSTRACT

OBJECTIVE: The aim of this study was to delineate the clinical and socioeconomic variables associated with shunt revision in pediatric patients presenting to the emergency department (ED) with concerns of ventricular shunt malfunction. METHODS: A retrospective analysis of pediatric ED consultations for shunt malfunction over a 1-year period was conducted, examining clinical symptoms, radiographic findings, and socioeconomic variables. Sensitivities, specificities, and positive and negative predictive values were calculated for each presenting symptom collected. Logistic regression models were used to estimate the odds ratios for shunt revision based on these variables, and multivariate analyses were used to adjust for potential confounders. RESULTS: Of the 271 ED visits from 137 patients, 19.2% resulted in shunt revision. Increased ventricle size on imaging (OR 11.38, p < 0.001), shunt site swelling (OR 9.04, p = 0.01), bradycardia (OR 7.08, p < 0.001), and lethargy (OR 5.77, p < 0.001) were significantly associated with shunt revision. Seizure-like activity was inversely related to revision needs (OR 0.24, p < 0.001). Patients with private or self-pay insurance were more likely to undergo revision compared with those with public insurance (p = 0.028). Multivariate analysis further confirmed the significant associations of increased ventricle size, lethargy, and bradycardia with shunt revision, while also revealing that seizure-like activity inversely affected the likelihood of revision. Patients with severe cognitive and language disabilities were more likely to be admitted to the hospital from the ED but were not more likely to undergo revision. CONCLUSIONS: Clinical signs such as increased ventricle size, shunt site swelling, bradycardia, and lethargy may be strong predictors of the need for shunt revision in pediatric patients presenting to the ED with concerns of shunt malfunction. Socioeconomic factors play a less clear role in predicting shunt revision and admission from the ED; however, the nature of their influence is unclear. These findings can help inform clinical decision-making and optimize resource utilization in the ED.


Subject(s)
Emergency Service, Hospital , Humans , Male , Female , Retrospective Studies , Child , Child, Preschool , Infant , Adolescent , Reoperation/statistics & numerical data , Hydrocephalus/surgery , Socioeconomic Factors , Cerebrospinal Fluid Shunts , Equipment Failure
15.
J Neurosurg Pediatr ; 34(1): 84-93, 2024 Jul 01.
Article in English | MEDLINE | ID: mdl-38608296

ABSTRACT

OBJECTIVE: Hydrocephalus is a neurological disorder with an incidence of 80-125 per 100,000 births in the United States. The most common treatment, ventricular shunting, has a failure rate of up to 85% within 10 years of placement. The authors aimed to analyze the association between ventricular catheter (VC) tissue obstructions and shunt malfunction for each hydrocephalus etiology. METHODS: Patient information was collected from 5 hospitals and entered into a REDCap (Research Electronic Data Capture) database by hydrocephalus etiology. The hardware samples were fixed, and each VC tip drainage hole was classified by tissue obstruction after macroscopic analysis. Shunt malfunction data, including shunt revision rate, time to failure, and age at surgery, were correlated with the degree of tissue obstruction in VCs for each etiology. RESULTS: Posthemorrhagic hydrocephalus was the most common etiology (48.9% of total cases). Proximal catheter obstruction was the most frequent cause of hardware removal (90.4%). Myelomeningocele (44% ± 29%), other congenital etiologies (48% ± 40%), hydrocephalus with brain tumors (45% ± 35%), and posthemorrhagic hydrocephalus (41% ± 35%) showed tissue aggregates in more than 40% of the VC holes. A total of 76.8% of samples removed because of symptoms of obstruction showed cellular or tissue aggregates. No conclusive etiological associations were detected when correlating the percentage of holes with tissue for each VC and age at surgery, shunt revision rates, or time between shunt implantation and removal. CONCLUSIONS: The proximal VC obstruction was accompanied by tissue aggregates in 76.8% of cases. However, the presence of tissue in the VC did not seem to be associated with hydrocephalus etiology.


Subject(s)
Equipment Failure , Hydrocephalus , Humans , Hydrocephalus/surgery , Hydrocephalus/etiology , Male , Female , Infant , Cerebrospinal Fluid Shunts/adverse effects , Child, Preschool , Catheter Obstruction/etiology , Ventriculoperitoneal Shunt/adverse effects , Child , Infant, Newborn , Reoperation/statistics & numerical data , Retrospective Studies , Brain Neoplasms/surgery , Brain Neoplasms/complications , Adolescent , Meningomyelocele/complications , Meningomyelocele/surgery
16.
Pacing Clin Electrophysiol ; 47(7): 878-884, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38661716

ABSTRACT

INTRODUCTION: Catheter ablation (CA) can interfere with cardiac implantable electronic device (CIED) function. The safety of CA in the 1st year after CIED implantation/lead revision is uncertain. METHODS: This single center, retrospective cohort included patients who underwent CA between 2012 and 2017 and had a CIED implant/lead revision within the preceding year. We assessed the frequency of device/lead malfunctions in this population. RESULTS: We identified 1810 CAs in patients between 2012 and 2017, with 170 CAs in 163 patients within a year of a CIED implant/lead revision. Mean age 68 ± 12 years (68% men). Time between the CIED procedure and CA was 158 ± 99 days. The CA procedures included AF ablation (n = 57, 34%), AV node ablation (n = 40, 24%), SVT ablation (n = 37, 22%), and PVC/VT ablations (n = 36, 21%). The cumulative frequency of lead dislodgement, significant CIED dysfunction, and/or CIED-related infection following CA was (n = 1/170, 0.6%). There was a single atrial lead dislodgement (0.6%). There were no instances of power-on-reset or CIED-related infection. Following CA, there was no significant difference in RA or RV lead sensing (p = 0.52 and 0.84 respectively) or thresholds (p = 0.94 and 0.17 respectively). The RA impedance slightly decreased post-CA from 474 ± 80 Ohms to 460 ± 73 Ohms (p = 0.002), as did the RV impedance (from 515 ± 111 Ohms to 497 ± 98 Ohms, p < 0.0001). CONCLUSIONS: CA can be performed within 1 year following CIED implantation/lead revision with a low risk of CIED/lead malfunction or lead dislodgement. The ideal time to perform CA after a CIED remains uncertain.


Subject(s)
Catheter Ablation , Defibrillators, Implantable , Pacemaker, Artificial , Humans , Male , Female , Retrospective Studies , Aged , Catheter Ablation/instrumentation , Equipment Failure
17.
Heart Rhythm ; 2024 Apr 02.
Article in English | MEDLINE | ID: mdl-38574791

ABSTRACT

BACKGROUND: One common mode of lead failure is insulation breach, which may result in myopotential noise and device malfunction. "Pseudo-unipolarization" of bipolar pacing stimuli, as observed from a routine 12-lead electrocardiogram (ECG) due to stimulus current leak, has been observed with insulation breaches. OBJECTIVE: We sought to characterize this electrocardiographic finding to detect this type of lead malfunction. METHODS: A total of 138 transvenous leads were analyzed, including 88 with known malfunction and 50 normal leads. The amplitude of a bipolar pacing stimulus on the ECG was recorded and compared with a control data set of newly implanted leads with bipolar stimuli normalized for output. RESULTS: The malfunction group consisted of 61% right atrium and 39% right ventricle leads with mean pacing output of 2.74 V at 0.5 ms. There was a significant difference in ECG bipolar stimulus amplitudes at time of identification of failure (7.89 ± 7.56 mm/V; P < .001) compared with those of normal leads (0.86 ± 0.41 mm/V). Receiver operating characteristic curve for the prediction of lead malfunction based on absolute ECG amplitude displayed an area under the curve of 0.93 (95% CI, 0.891-0.969). When normalized for programmed stimulus output, a cutoff of 5 mm/V demonstrated a sensitivity of 91% and a specificity of 92% (area under the curve, 0.967; 95% CI, 0.938-0.996). CONCLUSION: The maximum amplitude of a bipolar pacing stimulus on the ECG is significantly lower in normal functioning leads compared with those with known malfunction. This simply derived variable demonstrated good accuracy at identifying lead failure due to insulation breach.

18.
Heart Rhythm O2 ; 5(3): 189-193, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38560371

ABSTRACT

The incidence of cardiac implantable electronic device (CIED) malfunctions caused by radiotherapy (RT) is approximately 5%. Although individual national guidelines and expert consensus documents exist, the increased use of RT to treat various cancers points out the need for a standardized document to guide risk assessment and management of CIEDs during RT. We describe potential adverse RT-related events on CIEDs as well as the proposed mechanism of dysfunction. We review the main current guidelines and recommendations, emphasizing similarities and differences.

19.
Curr Top Med Chem ; 2024 Apr 05.
Article in English | MEDLINE | ID: mdl-38591201

ABSTRACT

Neurodegenerative diseases are emerging as a global health concern in the current sce-nario, and their association with mitochondrial defects has been a potential area of research. Mi-tochondria, one of the essential organelles of the cell, serve as the cell's powerhouse, producing energy and ensuring cellular health. Neurodegenerative diseases such as Alzheimer's, Parkinson's, Huntington's, amyotrophic lateral sclerosis, and Pelizaeus-Merzbacher disease have been found to be primarily triggered by mitochondrial malfunction. One of the key byproducts of mitochondrial respiration, reactive oxygen species, also contributes significantly to mitochondrial DNA muta-tions that eventually cause mitochondrial breakdown. This review paper comprehensively examines the potential of therapeutic biomolecules, specifi-cally mitochondria-specific antioxidants, in mitigating the impact of mitochondrial defects on neurodegenerative diseases. It provides a detailed analysis of the mechanisms involved in mito-chondrial dysfunction, the potential therapeutic targets of these biomolecules, and their structure-activity relationship information are also discussed in this review. Various research articles and publications were used extensively in compiling the data, and the structures of biomolecules were prepared using software such as ChemDraw and ChemSketch. Crucial elements triggering mitochondrial abnormalities were identified and a tabular compilation of bioactive antioxidant compounds along with their therapeutic targets, was presented. Mitochondria-specific antioxidant therapy is an innovative and promising strategy for the man-agement of neurodegenerative diseases associated with mitochondrial defects. This review pro-vides a thorough summary of the current state of research and promising avenues of research and development in this field, emphasizing the importance of further investigations and clinical trials to elucidate their therapeutic benefits.

20.
Sensors (Basel) ; 24(7)2024 Mar 26.
Article in English | MEDLINE | ID: mdl-38610337

ABSTRACT

Low-power embedded systems have been widely used in a variety of applications, allowing devices to efficiently collect and exchange data while minimizing energy consumption. However, the lack of extensive maintenance procedures designed specifically for low-power systems, coupled with constraints on anticipating faults and monitoring capacities, presents notable difficulties and intricacies in identifying failures and customized reaction mechanisms. The proposed approach seeks to address the gaps in current resource management frameworks and maintenance protocols for low-power embedded systems. Furthermore, this paper offers a trilateral framework that provides periodic prescriptions to stakeholders, a periodic control mechanism for automated actions and messages to prevent breakdowns, and a backup AI malfunction detection module to prevent the system from accessing any stress points. To evaluate the AI malfunction detection module approach, three novel autonomous embedded systems based on different ARM Cortex cores have been specifically designed and developed. Real-life results obtained from the testing of the proposed AI malfunction detection module in the developed embedded systems demonstrated outstanding performance, with metrics consistently exceeding 98%. This affirms the efficacy and reliability of the developed approach in enhancing the fault tolerance and maintenance capabilities of low-power embedded systems.