Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 401
Filter
1.
Heliyon ; 10(16): e36149, 2024 Aug 30.
Article in English | MEDLINE | ID: mdl-39262968

ABSTRACT

The rotating-wall vessel (RWV) bioreactor, a 3D suspension culture system, faces challenges related to non-uniform tissue growth during the incubation of bone and heart tissues. Okra mucilage, an extract from okra pods with non-Newtonian rheological properties, has shown potential as a plasma replacement agent and has no induced cytotoxic effects. In this study, we investigated the flow structure of okra mucilage in rotating wall vessel system. By modifying the RWV and adding okra mucilage, we analyzed the flow structure using a high-speed camera and particle image velocimetry (PIV). Our results showed that okra mucilage creates a concentric circle-shaped rigid-like rotation at all rotation speeds (1-50 rpm). The high viscosity of okra mucilage resulted in a low terminal velocity for microparticles and quick response to rotational movements. These findings suggest that okra mucilage has the potential to enhance the uniformity of tissue growth in RWV systems by stabilizing the flow structure and reducing microparticle sedimentation.

2.
Ultrasound Med Biol ; 2024 Sep 06.
Article in English | MEDLINE | ID: mdl-39244482

ABSTRACT

OBJECTIVE: Local flow dynamics impact atherosclerosis yet are difficult to quantify with conventional ultrasound techniques. This study investigates the performance of ultrasound vector flow imaging (US-VFI) with and without ultrasound contrast agents in the healthy femoral bifurcation. METHODS: High-frame-rate ultrasound data with incremental acoustic outputs were acquired in the femoral bifurcations of 20 healthy subjects before (50V) and after contrast injection (2V, 5V and 10V). 2-D blood-velocity profiles were obtained through native blood speckle tracking (BST) and contrast tracking (echo particle image velocimetry [echoPIV]). As a reference, 4-D flow magnetic resonance imaging (4-D flow MRI) was acquired. Contrast-to-background ratio and vector correlation were used to assess the quality of the US-VFI acquisitions. Spatiotemporal velocity profiles were extracted, from which peak velocities (PSV) were compared between the modalities. Furthermore, root-mean-square error analysis was performed. RESULTS: US-VFI was successful in 99% of the cases and optimal VFI quality was established with the 10V echoPIV and BST settings. A good correspondence between 10V echoPIV and BST was found, with a mean PSV difference of -0.5 cm/s (limits of agreement: -14.1-13.2). Both US-VFI techniques compared well with 4-D flow MRI, with a mean PSV difference of 1.4 cm/s (-18.7-21.6) between 10V echoPIV and MRI, and 0.3 cm/s (-23.8-24.4) between BST and MRI. Similar complex flow patterns among all modalities were observed. CONCLUSION: 2-D blood-flow quantification of femoral bifurcation is feasible with echoPIV and BST. Both modalities showed good agreement compared to 4-D flow MRI. For the femoral tract the administration of contrast was not needed to increase the echogenicity of the blood for optimal image quality.

3.
Biomimetics (Basel) ; 9(9)2024 Sep 14.
Article in English | MEDLINE | ID: mdl-39329575

ABSTRACT

In this work, micro air vehicles (MAVs) equipped with bio-inspired wings are investigated experimentally in wind tunnel. The starting point is that insects such as dragonflies, butterflies and locusts have wings with rigid tubular elements (corrugation) connected by flexible parts (profiling). So far, it is important to understand the specific aerodynamic effects of corrugation and profiling as applied to conventional wings for the optimization of low-Reynolds-number aerodynamics. The present study, in comparison to previous investigations on the topic, considers whole MAVs rather than isolated wings. A planform with a low aperture-to-chord ratio is employed in order to investigate the interaction between large tip vortices and the flow over the wing surface at large angles of incidence. Comparisons are made by measuring global aerodynamic loads using force balance, specifically drag and lift, and detailed local velocity fields over wing surfaces, by means of particle image velocimetry (PIV). This type of combined global-local investigation allows describing and relating overall MAV performance to detailed high-resolution flow fields. The results indicate that the combination of wing corrugation and profiling gives effective enhancements in performance, around 50%, in comparison to the classical flat-plate configuration. These results are particularly relevant in the framework of low-aspect-ratio MAVs, undergoing beneficial interactions between tip vortices and large-scale separation.

4.
HardwareX ; 19: e00563, 2024 Sep.
Article in English | MEDLINE | ID: mdl-39220164

ABSTRACT

Particle Image Velocimetry (PIV) is considered the gold standard technique for flow visualization. However, its cost (at least tens of thousands of dollars) can prove inhibitive in its standard form. This article presents an alternative design, leveraging off-the-shelf and open-source options for each key component involved: camera, laser module, optical components, tracer particles, and analysis software. Flow visualization is a crucial technique to connect theory to practice in teaching and researching fluid mechanics. Despite the ubiquity of this field within engineering curricula, many undergraduate institutions globally forego utilizing such equipment, given the barriers to setting it up. The availability of this low-cost alternative (∼$500) that can be built in-house offers a path forward. Characterization was done by visualizing the rotational flow generated by a magnetic stirrer in a cylindrical beaker. The velocity magnitude around the stirrer bar measured by the low-cost PIV system was compared to expected values calculated analytically. The percent difference was between 1-2% when the flow stayed two-dimensional but increased as the flow began developing into more of a 3-D flow. Repeatability varied no more than 6% between experiments. This platform holds the potential for reliable replication across institutions broadly.

5.
Sensors (Basel) ; 24(17)2024 Aug 28.
Article in English | MEDLINE | ID: mdl-39275494

ABSTRACT

In this study, ultrasonic sensors were used to measure the vertical vortex at flood discharge outlets in real time, and numerical simulations and model experiments were conducted. When a sound signal passes through a vortex, its propagation characteristics will change, which helps to determine the existence of the vortex. Moreover, its characteristic parameters can be obtained through inversion. In this paper, first, the theories of acoustic measurement methods were introduced and their feasibility was verified through a comparison between Particle Image Velocimetry (PIV) measurement and numerical simulation results. Then, the Computational Fluid Dynamics (CFD) method was used to simulate the vertical vortex at the flood discharge outlets of hydraulic structures and the simulation data were restored to the actual size at scale. Finally, acoustic numerical simulations of actual vortex data were conducted, and ultrasonic sensors were used to measure the velocity of a simplified vertical vortex model under laboratory conditions. The research results indicate that the acoustic measurement method proposed in this article is effective in the measurement of the characteristic parameters of vertical vortex with a core radius of 0.03~0.05 m and a maximum tangential velocity of 0.5 m/s, the measurement error of the maximum tangential velocity is within 10%.

6.
Artif Organs ; 2024 Aug 27.
Article in English | MEDLINE | ID: mdl-39189702

ABSTRACT

BACKGROUND: Hemolysis in mechanical circulatory support systems is currently determined quantitatively. To also locally resolve hemolysis, we are developing a fluorescent hemolysis detection method. This requires a translucent two-phase blood analog fluid combined with particle image velocimetry, an optical flow field measurement. The blood analog fluid is composed of red blood cell surrogates. However, producing surrogates in sufficient volume is a challenge. We therefore present a high-volume and high-concentration production for our surrogates: ghost cells, hemoglobin-depleted erythrocytes. METHODS: In the ghost cell production, the hemoglobin is removed by a repeated controlled osmolar lysis. We have varied the solution mixture, centrifugation time, and centrifugation force in order to increase production efficiency. The production is characterized by measurements of output volume, hematocrit, transparency, and rheology of the blood analog fluid. RESULTS: The volume of produced ghost cells was significantly increased, and reproducibility was improved. An average production of 389 mL of ghost cells were achieved per day. Those ghost cells diluted in plasma have a rheology similar to blood while being permeable to light. CONCLUSION: The volume of ghost cells produced is sufficient for optical measurements as particle image velocimetry in mechanical circulatory support systems. This makes further work on experimental measurements for a locally resolved hemolysis detection possible.

7.
Front Bioeng Biotechnol ; 12: 1421714, 2024.
Article in English | MEDLINE | ID: mdl-39086499

ABSTRACT

Acute ischemic stroke caused by large vessel occlusions is being increasingly treated with neurovascular interventions. The hemodynamics within the collateral system of the circle of Willis (CoW) hemodynamics play a fundamental role in therapy success. However, transient in vivo data on pathological collateral flow during large vessel occlusions are not available. Moreover, there are no flow models that accurately simulate the hemodynamic conditions in the CoW during large vessel occlusions. We used a circulatory loop to generate highly reproducible cerebrovascular-like flows and pressures and used non-invasive flow visualization and high-resolution flow and pressure measurements to acquire detailed, time-dependent hemodynamics inside an anatomical phantom of the CoW. After calibrating a physiological reference case, we induced occlusions in the 1. middle cerebral artery, 2. terminal carotid artery, and 3. basilar artery; and measured the left posterior communicating artery flow. Mean arterial pressure and pulse pressure remained unchanged in the different occlusion cases compared to the physiological reference case, while total cerebral flow decreased by up to 19%. In all three occlusion cases, reversed flow was found in the left posterior communicating artery compared to the reference case with different flow magnitudes and pulsatility index values. The experimental results were compared with clinical findings, demonstrating the capability of this realistic cerebrovascular flow setup. This novel cerebrovascular flow setup opens the possibility for investigating different topics of neurovascular interventions under various clinical conditions in controlled preclinical laboratory studies.

8.
Ann Biomed Eng ; 2024 Aug 05.
Article in English | MEDLINE | ID: mdl-39103737

ABSTRACT

PURPOSE: To investigate the effect of changing systolic and diastolic blood pressures (SBP and DBP, respectively) on sinus flow and valvular and epicardial coronary flow dynamics after TAVR and SAVR. METHODS: SAPIEN 3 and Magna valves were deployed in an idealized aortic root model as part of a pulse duplicating left heart flow loop simulator. Different combinations of SBP and DBP were applied to the test setup and the resulting change in total coronary flow from baseline (120/60 mmHg), effective orifice area (EOA), and left ventricular (LV) workload, with each combination, was assessed. In addition, particle image velocimetry was used to assess the Laplacian of pressure ( ∇ 2 P ) in the sinus, coronary and main flow velocities, the energy dissipation rate (EDR) in the sinus and the LV workload. RESULTS: This study shows that under an elevated SBP, there is an increase in the total coronary flow, EOA, LV workload, peak velocities downstream of the valve, ∇ 2 P , and EDR. With an elevated DBP, there was an increase in the total coronary flow and ∇ 2 P . However, EOA and LV workload decreased with an increase in DBP, and EDR increased with a decrease in DBP. CONCLUSIONS: Blood pressure alters the hemodynamics in the sinus and downstream flow following aortic valve replacement, potentially influencing outcomes in some patients.

9.
J Exp Biol ; 227(15)2024 Aug 01.
Article in English | MEDLINE | ID: mdl-39022908

ABSTRACT

Complex hydrodynamics abound in natural streams, yet the selective pressures these impose upon different size classes of fish are not well understood. Attached vortices are produced by relatively large objects that block freestream flow, which fish routinely utilize for flow refuging. To test how flow refuging and the potential harvesting of energy (as seen in Kármán gaiting) vary across size classes in rainbow trout (Oncorhynchus mykiss; fingerling, 8 cm; parr, 14 cm; adult, 22 cm; n=4 per size class), we used a water flume (4100 l; freestream flow at 65 cm s-1) and created vortices using 45 deg wing dams of varying size (small, 15 cm; medium, 31 cm; large, 48 cm). We monitored microhabitat selection and swimming kinematics of individual trout and measured the flow field in the wake of wing dams using time-resolved particle image velocimetry (PIV). Trout of each size class preferentially swam in vortices rather than the freestream, but the capacity to flow refuge varied according to the ratio of vortex width to fish length (WV:LF). Consistent refuging behavior was exhibited when WV:LF≥1.5. All size classes exhibited increased wavelength and Strouhal number and decreased tailbeat frequency within vortices compared with freestream, suggesting that swimming in vortices requires less power output. In 17% of the trials, fish preferentially swam in a manner that suggests energy harvesting from the shear layer. Our results can inform efforts toward riparian restoration and fishway design to improve salmonid conservation.


Subject(s)
Body Size , Oncorhynchus mykiss , Swimming , Animals , Oncorhynchus mykiss/physiology , Swimming/physiology , Biomechanical Phenomena , Hydrodynamics , Rheology , Water Movements , Rivers , Ecosystem
10.
JTCVS Open ; 19: 61-67, 2024 Jun.
Article in English | MEDLINE | ID: mdl-39015440

ABSTRACT

Objective: The use of the transcatheter aortic valve in low-risk patients might lead to a second intervention due to the deterioration of the first 1. Understanding the implantation height is key to an effective redo transcatheter aortic valve replacement treatment. Methods: The effects of implantation height on the performance of a balloon-expandable valve within a self-expandable valve were assessed using hemodynamic testing and particle image velocimetry. The hemodynamic performances, leaflet kinematics, and turbulent shear stresses were measured and compared. Results: When a second balloon-expandable valve was positioned at varying heights relative to the first self-expandable valve, the leaflet motion of the first valve transitioned from free opening and closing to overhanging, and eventually to being entirely pinned to the stent, forming a neo-skirt. When the leaflets of the self-expandable valve could move freely, a decrease in regurgitation fraction was observed, but with an increased pressure gradient across the valve. Flow visualization indicated that the overhanging leaflets disrupted the flow, generating a higher level of turbulence. Conclusions: This study suggests that the overhanging leaflets should be avoided, whereas the other 2 scenarios should be carefully evaluated based on an individual patient's anatomy and the cause of failure of the first valve.

11.
Front Cardiovasc Med ; 11: 1432784, 2024.
Article in English | MEDLINE | ID: mdl-39026997

ABSTRACT

Introduction: Primary pulmonary vein stenosis (PVS) is a rare congenital heart disease that proves to be a clinical challenge due to the rapidly progressive disease course and high rates of treatment complications. PVS intervention is frequently faced with in-stent restenosis and persistent disease progression despite initial venous recanalization with balloon angioplasty or stenting. Alterations in wall shear stress (WSS) have been previously associated with neointimal hyperplasia and venous stenosis underlying PVS progression. Thus, the development of patient-specific three-dimensional (3D) in vitro models is needed to further investigate the biomechanical outcomes of endovascular and surgical interventions. Methods: In this study, deidentified computed tomography images from three patients were segmented to generate perfusable phantom models of pulmonary veins before and after catheterization. These 3D reconstructions were 3D printed using a clear resin ink and used in a benchtop experimental setup. Computational fluid dynamic (CFD) analysis was performed on models in silico utilizing Doppler echocardiography data to represent the in vivo flow conditions at the inlets. Particle image velocimetry was conducted using the benchtop perfusion setup to analyze WSS and velocity profiles and the results were compared with those predicted by the CFD model. Results: Our findings indicated areas of undesirable alterations in WSS before and after catheterization, in comparison with the published baseline levels in the healthy in vivo tissues that may lead to regional disease progression. Discussion: The established patient-specific 3D in vitro models and the developed in vitro-in silico platform demonstrate great promise to refine interventional approaches and mitigate complications in treating patients with primary PVS.

12.
Entropy (Basel) ; 26(7)2024 Jun 30.
Article in English | MEDLINE | ID: mdl-39056935

ABSTRACT

In particle image velocimetry (PIV) experiments, background noise inevitably exists in the particle images when a particle image is being captured or transmitted, which blurs the particle image, reduces the information entropy of the image, and finally makes the obtained flow field inaccurate. Taking a low-quality original particle image as the research object in this research, a frequency domain processing method based on wavelet decomposition and reconstruction was applied to perform particle image pre-processing. Information entropy analysis was used to evaluate the effect of image processing. The results showed that useful high-frequency particle information representing particle image details in the original particle image was effectively extracted and enhanced, and the image background noise was significantly weakened. Then, information entropy analysis of the image revealed that compared with the unprocessed original particle image, the reconstructed particle image contained more effective details of the particles with higher information entropy. Based on reconstructed particle images, a more accurate flow field can be obtained within a lower error range.

13.
Artif Organs ; 2024 Jul 03.
Article in English | MEDLINE | ID: mdl-38957988

ABSTRACT

BACKGROUND: The Food and Drug Administration (FDA) blood pump is an open-source benchmark cardiovascular device introduced for validating computational and experimental performance analysis tools. The time-resolved velocity field for the whole impeller has not been established, as is undertaken in this particle image velocimetry (PIV) study. The level of instantaneous velocity fluctuations is important, to assess the flow-induced rotor vibrations which may contribute to the total blood damage. METHODS: To document these factors, time-resolved two-dimensional PIV experiments were performed that were precisely phase-locked with the impeller rotation angle. The velocity fields in the impeller and in the volute conformed with the previous single blade passage experiments of literature. RESULTS: Depending on the impeller orientation, present experiments showed that volute outlet nozzle flow can fluctuate up to 34% during impeller rotation, with a maximum standard experimental uncertainty of 2.2%. Likewise, the flow fields in each impeller passage also altered in average 33.5%. Considerably different vortex patterns were observed for different blade passages, with the largest vortical structures reaching an average core radii of 7 mm. The constant volute area employed in the FDA pump design contributes to the observed velocity imbalance, as illustrated in our velocity measurements. CONCLUSIONS: By introducing the impeller orientation parameter for the nozzle flow, this study considers the possible uncertainties influencing pump flow. Expanding the available literature data, analysis of inter-blade relative velocity fields is provided here for the first-time to the best of our knowledge. Consequently, our research fills a critical knowledge gap in the understanding of the flow dynamics of an important benchmark cardiovascular device. This study prompts the need for improved hydrodynamic designs and optimized devices to be used as benchmark test devices, to build more confidence and safety in future ventricular assist device performance assessment studies.

14.
ACS Appl Mater Interfaces ; 16(26): 34313-34325, 2024 Jul 03.
Article in English | MEDLINE | ID: mdl-38907697

ABSTRACT

Boiling heat transfer has a high thermal efficiency by latent heat absorption, which makes it an attractive process for cooling electronic device chips. Critical heat flux (CHF), the maximum heat flux, is a crucial factor determining the operating range of the boiling applications. The CHF can be enhanced by improving the fluid supply to the boiling surface. Herein, micropillar interfacial surfaces have been proposed to increase the CHF by increasing the rewetting flow, which determines the fluid-supply capacity near the bubble contact line. A state-of-art two-phase particle image velocimetry (two-phase PIV) technique is introduced for rewetting flow measurement on micropillar structures (MPSs) to analyze the CHF-enhancement mechanism. The two-phase PIV visualization setup offers high spatial (∼120 µm) and temporal (∼2000 Hz) resolutions for measuring rewetting flow during bubble growth. The MPS samples exhibit enhanced CHF and rewetting flows compared to those on a plain surface. The roughest case, D04G10 sample, had a CHF of 164 W/cm2, 1.84 times higher than that of the plain surface. The D04G10 sample also recorded the highest rewetting velocity of 0.311 m/s, 4.7 times higher than that of the plain surface. The comparison between the rewetting flow and wicking performance shows that wicking-induced flow accounted for a substantial part (∼17%) of the rewetting flow and contributed significantly to the CHF enhancement owing to large rewetting flow by delaying vapor-film formation. Based on these findings, a new CHF model suggested by introducing the rewetting parameter shows a high CHF prediction accuracy of 94%.

15.
Front Neurol ; 15: 1364105, 2024.
Article in English | MEDLINE | ID: mdl-38831781

ABSTRACT

Background: Understanding the risk factors leading to intracranial aneurysm (IA) rupture have still not been fully clarified. They are vital for proper medical guidance of patients harboring unruptured IAs. Clarifying the hemodynamics associated with the point of rupture could help could provide useful information about some of the risk factors. Thus far, few studies have studied this issue with often diverging conclusions. Methods: We identified a point of rupture in patients operated for an IAs during surgery, using a combination of preoperative computed tomography (CT) and computed tomography angiography (CTA). Hemodynamic parameters were calculated both for the aneurysm sac as a whole and the point of rupture. In two cases, the results of CFD were compared with those of the experiment using particle image velocimetry (PIV). Results: We were able to identify 6 aneurysms with a well-demarcated point of rupture. In four aneurysms, the rupture point was near the vortex with low wall shear stress (WSS) and high oscillatory shear index (OSI). In one case, the rupture point was in the flow jet with high WSS. In the last case, the rupture point was in the significant bleb and no specific hemodynamic parameters were found. The CFD results were verified in the PIV part of the study. Conclusion: Our study shows that different hemodynamic scenarios are associated with the site of IA rupture. The numerical simulations were confirmed by laboratory models. This study further supports the hypothesis that various pathological pathways may lead to aneurysm wall damage resulting in its rupture.

16.
Fundam Res ; 4(2): 334-343, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38933520

ABSTRACT

By conducting a two-dimensional experimental study, this paper aims to enhance the understanding of the mechanism of sand convective motions in the vicinity of a wall subjected to long-term cyclic lateral loadings. The experimental tests were conducted in a rectangular sandbox with a transparent front-wall, through which the process of sand particle motions could be recorded by using a high-resolution digital camera. The images were processed with a high time-resolved PIV (Particle Image Velocimetry) system. Based on the experimental data, this work (1) presents the sand flow field in the convective zones; (2) provides means to describe the convection mechanism; (3) proposes the relationships between the loading conditions and dimensions of the region with intense sand movement; and (4) elaborates the similarity of the sand flow velocity structure within the sand convective zones.

17.
J Med Imaging (Bellingham) ; 11(3): 037001, 2024 May.
Article in English | MEDLINE | ID: mdl-38765874

ABSTRACT

Purpose: To investigate the accuracy of high-framerate echo particle image velocimetry (ePIV) and computational fluid dynamics (CFD) for determining velocity vectors in femoral bifurcation models through comparison with optical particle image velocimetry (oPIV). Approach: Separate femoral bifurcation models were built for oPIV and ePIV measurements of a non-stenosed (control) and a 75%-area stenosed common femoral artery. A flow loop was used to create triphasic pulsatile flow. In-plane velocity vectors were measured with oPIV and ePIV. Flow was simulated with CFD using boundary conditions from ePIV and additional duplex-ultrasound (DUS) measurements. Mean differences and 95%-limits of agreement (1.96*SD) of the velocity magnitudes in space and time were compared, and the similarity of vector complexity (VC) and time-averaged wall shear stress (TAWSS) was assessed. Results: Similar flow features were observed between modalities with velocities up to 110 and 330 cm/s in the control and the stenosed model, respectively. Relative to oPIV, ePIV and CFD-ePIV showed negligible mean differences in velocity (<3 cm/s), with limits of agreement of ±25 cm/s (control) and ±34 cm/s (stenosed). CFD-DUS overestimated velocities with limits of agreements of 13±40 and 16.1±55 cm/s for the control and stenosed model, respectively. VC showed good agreement, whereas TAWSS showed similar trends but with higher values for ePIV, CFD-DUS, and CFD-ePIV compared to oPIV. Conclusions: EPIV and CFD-ePIV can accurately measure complex flow features in the femoral bifurcation and around a stenosis. CFD-DUS showed larger deviations in velocities making it a less robust technique for hemodynamical assessment. The applied ePIV and CFD techniques enable two- and three-dimensional assessment of local hemodynamics with high spatiotemporal resolution and thereby overcome key limitations of current clinical modalities making them an attractive and cost-effective alternative for hemodynamical assessment in clinical practice.

18.
Int J Pharm ; 658: 124209, 2024 Jun 10.
Article in English | MEDLINE | ID: mdl-38718973

ABSTRACT

The USP Rotating Basket Dissolution Testing Apparatus 1 is listed in the USP as one of the tools to assess dissolution of oral solid dosage forms. Baskets of different mesh sizes can be used to differentiate between dissolution profiles of different formulations. Here, we used Particle Image Velocimetry (PIV) to study the hydrodynamics of the USP Apparatus 1 using baskets with different mesh openings (10-, 20- and 40-mesh) revolving at 100 rpm, when the vessel was filled with 500 mL. The velocity profiles throughout the liquid were found to vary significantly using baskets of different mesh sizes, typically increasing with increased size of the opening of the basket mesh, especially for axial and radial velocities. This, in turn, resulted in a significantly different flow rate through the basket, which can be expected to significantly impact the dissolution rate of the drug product. A comparison between the results of this work with those of a previous study with a 900-mL fill volume (Sirasitthichoke et al., Intern. J. Pharmaceutics, 2021, 607: 120976), shows that although the hydrodynamics in the USP Apparatus 1 changed with fill level in the vessel, the flow rate through the basket was not significantly affected. This implies that tablets dissolving in the two systems would experience similar tablet-liquid medium mass transfer coefficients, and therefore similar initial dissolution rates, but different dissolution profiles because of the difference in volume.


Subject(s)
Drug Liberation , Hydrodynamics , Rheology , Solubility , Tablets , Rheology/methods , Drug Compounding/methods , Drug Compounding/instrumentation , Chemistry, Pharmaceutical/methods , Particle Size , Technology, Pharmaceutical/methods
19.
JSES Int ; 8(3): 570-576, 2024 May.
Article in English | MEDLINE | ID: mdl-38707573

ABSTRACT

Background: The relationship between lower mobility, as measured by the elbow forward translation motion (T-motion) test, a new indicator of shoulder joint complex movement that measures elbow position when both dorsal hands are placed on the iliac crest while in a sitting position, and the parameters calculated by ultrasonography is unknown. The purpose of this study was to investigate the limiting factors of T-motion through motion analysis of the humeral head and rotator cuff muscles using ultrasonography in college baseball players. Methods: Thirteen college baseball players participated in this cross-sectional study. The shortest distance from the posterior edge of the glenoid to the humeral head was measured in the static and T-motion positions, and the difference was calculated as the humeral head translation. The velocity of the infraspinatus was calculated during shoulder internal/external rotation using the particle image velocimetry method. These parameters were compared between the throwing and nonthrowing sides to examine the limiting factors of T-motion. Results: This study indicated moderate-to-good reliability for the parameters calculated by ultrasonography. The mean anterior translation distance was significantly greater on the throwing side than on the nonthrowing side (r = 0.56, P = .015). The mean velocity of infraspinatus during internal rotation was significantly lower on the throwing side than on the nonthrowing side (r = 0.51, P = .028). Conclusion: Increased anterior translation of the humeral head and decreased the velocity of infraspinatus are likely correlated with reduced T-motion mobility in college baseball players. These methods showed potential for physical therapy assessment and intervention to prevent shoulder dysfunction.

20.
Front Med Technol ; 6: 1376649, 2024.
Article in English | MEDLINE | ID: mdl-38756328

ABSTRACT

This study aims to evaluate the fluid dynamic characteristics of the VenusP Valve System™ under varying cardiac outputs in vitro. A thorough hemodynamic study of the valve under physiological cardiac conditions was conducted and served as an independent assessment of the performance of the valve. Flow fields downstream of the valve near the pulmonary bifurcation were quantitatively studied by two-dimensional Particle Image Velocimetry (PIV). The obtained flow field was analyzed for potential regions of flow stasis and recirculation, and elevated shear stress and turbulence. High-speed en face imaging capturing the leaflet motion provided data for leaflet kinematic modeling. The experimental conditions for PIV studies were in accordance with ISO 5840-1:2021 standard, and two valves with different lengths and different orientations were studied. Results show good hemodynamics performance for the tested valves according to ISO 5840 standard without significant regions of flow stasis. Observed shear stress values are all well below established hemolysis limits.

SELECTION OF CITATIONS
SEARCH DETAIL