ABSTRACT

Sulfuric acid anodizing assisted by a hydrothermal sealing with inhibitors [Ce3+-Mo6+] was used to prevent pitting corrosion on spray-deposited hypereutectic Al-Si alloy (A390). An investigation concerning the evaluation of pitting corrosion resistance on the anodic oxide thin film with ions incorporated was carried out in NaCl solution using electrochemical measurements (i.e., potentiodynamic polarization and electrochemical impedance spectroscopy, EIS). The influence of Si phase morphology and size on the growth mechanism of an anodic oxide film was characterized by scanning electron microscopy (SEM) and X-ray diffraction (XRD). The results were then compared with those for its equivalent IM390 alloy (Al-17Si-4.5Cu-0.6Mg) produced through a conventional process ingot metallurgy, IM. The electrochemical findings indicate that sulfuric acid anodizing followed by a simple hot water sealing treatment was ineffective. In this manner, an intense attack was localized by pitting corrosion that occurred on the anodic oxide film in less than three days, as denoted by characteristic changes in the EIS spectra at the lowest frequencies. Improved results were achieved for Ce-Mo surface modification, which can provide better corrosion resistance on the aluminum alloys because no signs of pits were observed during the corrosion testing.

2.
Materials (Basel) ; 17(9)2024 Apr 24.
Article in English | MEDLINE | ID: mdl-38730781

ABSTRACT

In the present work, the influence of a corrosive environment and temperature on the corrosion resistance properties of duplex stainless steel S31803 was evaluated. The corrosive process was carried out using solutions of 1.5% HCl (m/m) and 6% FeCl3 (m/m), at temperatures of 25 and 50 °C. The microstructure of UNS S31803 duplex stainless steel is composed of two phases, ferrite and austenite, oriented in the rolling direction, containing a ferrite percentage of 46.2% in the rolling direction and 56.1% in the normal direction. Samples, when subjected to corrosive media and temperature, tend to decrease their mechanical property values. It was observed, in both corrosive media, that with increasing test temperature, there is an increase in the corrosion rate, both uniform and pitting. The sample in HCl solution obtained a uniform corrosion rate of 0.85% at 25 °C and 0.92% at 50 °C and pitting rates of 0.77% and 1.47% at the same temperatures, respectively. When tested in FeCl3 solution, it obtained uniform corrosion of 0.0006% and 0.93% and pitting of 0.53% and 18.5%, at the same temperatures. A reduction in dissolution potentials is also noted, thus characterizing greater corrosion in the samples with increasing temperature.

SELECTION OF CITATIONS
SEARCH DETAIL