1.
Acta sci. vet. (Impr.) ; 41: Pub. 1122, 2013. ilus
Article in Portuguese | VETINDEX | ID: biblio-1372472

ABSTRACT

Background: The feasibility of modular cemented prosthesis in the femoral diaphysis was demonstrated in dogs, but several authors report loosening of bone-cement-implant interface as a major complication and have yet to reach a consensus on the ideal cement layer thickness for reducing postoperative morbidity. The objective of this study was to evaluate the stabilization of the prosthesis using different thicknesses of cement layer, subjected to torsion forces. Materials, Methods & Results: For this study 48 femurs from 24 dogs weighing over 15 kg were used. The animals used did not have any prior diagnosis of bone or nutritional diseases, which was an exclusion criteria for this study. All biological materials were obtained immediately after death or euthanasia of the animal, and then subjected to conventional storage in a freezer at a temperature of - 24°C. The prosthesis was composed of a cylindrical part with rods for attachment to the intramedullary canal, made of alloy steel 316L. After thawing the femurs and subsequent stabilization at room temperature we performed osteotomies of the femoral diaphysis with an oscillating saw and the installation of the prosthesis. As preparatory measures for prosthesis fixation with cement, the intramedullary canals were cleaned, washed with saline and aspirated. They were separated in four groups, the first group with eight femurs used a cement mantle of 1.0 to 1.5 mm, the second group, with eight femurs, used a cement mantle of 2.0 to 2.5 mm and the third group, with eight femurs, used a cement layer of 3.0 to 3.5 mm. The femurs were submitted to destructive torsion tests using a universal testing machine with a load cell of 981 N (100 kg) and an essay speed of 22 mm / min. They were evaluated due to the values of torsional rigidity and maximum torque shown by the implant, bone and bone cement interface. The fourth group consisted of the remaining intact femurs, they were evaluated using the same torsion test used on the other groups. The results were analyzed using the Statistical Analysis System (SAS, 2001) and the normality of residuals was previously verified by the Shapiro-Wilk test. It was established to conduct the testing using an external rotation protocol in order to standardize, assuming a situation where the dog was in movement during a uniform curvilinear motion, trying to mimic a situation where the rotational forces were acting more significantly on the femur. Discussion: In our study the importance of cleaning up the intramedullary canal for proper bone cement penetration, a good reaming of the intramedullary canal and drying the area before the cement implantation was made clear. Statistical analysis showed that the thicknesses of the cement layer ranging from 1 mm to 2.5 mm, although bringing a gradual increase in maximum torque and torsional rigidity, are not sufficient to be statistically significant and may be considered equal in their biomechanical behavior assessed by this study. A similar result was found when we compared the 2 mm to 3.5 mm layers. The comparison that was statistically significant and can be considered in relation to the different biomechanical behavior of the cement layer was seen between the group I of 1 mm to 1.5 mm, and group III of 3 mm to 3.5 mm. Although some results were not statistically significant we must remember that, in absolute values, the torsional rigidity and maximum torque increased linearly with the increasing of the cement layer. From these results we can infer about the real advantage of using a thicker cement layer over an increment in the diameter of the intramedullary component, giving greater resistance to the prosthesis.


Subject(s)
Animals , Dogs , Prostheses and Implants/veterinary , Bone Cements/analysis , Femoral Fractures/rehabilitation , Femoral Fractures/veterinary , Biomechanical Phenomena , Dogs
2.
Acta sci. vet. (Online) ; 41: 01-07, 2013.
Article in Portuguese | VETINDEX | ID: vti-480145

ABSTRACT

Background: The feasibility of modular cemented prosthesis in the femoral diaphysis was demonstrated in dogs, but several authors report loosening of bone-cement-implant interface as a major complication and have yet to reach a consensus on the ideal cement layer thickness for reducing postoperative morbidity. The objective of this study was to evaluate the stabilization of the prosthesis using different thicknesses of cement layer, subjected to torsion forces. Materials, Methods & Results: For this study 48 femurs from 24 dogs weighing over 15 kg were used. The animals used did not have any prior diagnosis of bone or nutritional diseases, which was an exclusion criteria for this study. All biological materials were obtained immediately after death or euthanasia of the animal, and then subjected to conventional storage in a freezer at a temperature of - 24C. The prosthesis was composed of a cylindrical part with rods for attachment to the intramedullary canal, made of alloy steel 316L. After thawing the femurs and subsequent stabilization at room temperature we performed osteotomies of the femoral diaphysis with an oscillating saw and the installation of the prosthesis. As preparatory measures for prosthesis fixation with cement, the intramedullary canals were cleaned, washed with saline and aspirated. They were separated in four groups, the first group with eight femurs u


O fêmur canino é submetido a uma grande carga excêntrica durante a sustentação de peso e deambulação, sendo que suas propriedades biomecânicas afetam diretamente a forma como se comportam em relação às forças a que são submetidos no animal vivo. [...]

3.
Acta sci. vet. (Impr.) ; 41: 01-07, 2013.
Article in Portuguese | LILACS-Express | VETINDEX | ID: biblio-1457129

ABSTRACT

Background: The feasibility of modular cemented prosthesis in the femoral diaphysis was demonstrated in dogs, but several authors report loosening of bone-cement-implant interface as a major complication and have yet to reach a consensus on the ideal cement layer thickness for reducing postoperative morbidity. The objective of this study was to evaluate the stabilization of the prosthesis using different thicknesses of cement layer, subjected to torsion forces. Materials, Methods & Results: For this study 48 femurs from 24 dogs weighing over 15 kg were used. The animals used did not have any prior diagnosis of bone or nutritional diseases, which was an exclusion criteria for this study. All biological materials were obtained immediately after death or euthanasia of the animal, and then subjected to conventional storage in a freezer at a temperature of - 24C. The prosthesis was composed of a cylindrical part with rods for attachment to the intramedullary canal, made of alloy steel 316L. After thawing the femurs and subsequent stabilization at room temperature we performed osteotomies of the femoral diaphysis with an oscillating saw and the installation of the prosthesis. As preparatory measures for prosthesis fixation with cement, the intramedullary canals were cleaned, washed with saline and aspirated. They were separated in four groups, the first group with eight femurs u


O fêmur canino é submetido a uma grande carga excêntrica durante a sustentação de peso e deambulação, sendo que suas propriedades biomecânicas afetam diretamente a forma como se comportam em relação às forças a que são submetidos no animal vivo. [...]

4.
Rev. bras. eng. biomed ; 24(3): 183-192, dez. 2008. ilus, graf
Article in Portuguese | LILACS | ID: lil-548019

ABSTRACT

O objetivo deste estudo foi determinar a viabilidade de produção de uma prótese femoral de titânio garantindo a qualidade da matéria prima e as características das superfícies. Um protótipo foi criado pelo Método de Elementos Finitos em AutoCad® 2000. A simulação dos esforços demonstrou uma tensão de von Mises 8,1 vezes menor que a tensão crítica para escoamento do material. Na determinação dos constituintes metálicos, obteve-se: Fe  =   0,06%, Al  = 6,20%, V  = 3,57%, O  = 0,115%, N  = 0,003%, H  = 0,010%, e ausência de metais pesados. As propriedades elasto-plásticas da amostra tiveram valor médio de dureza de 4,45 (3,92 a 4,79) GPa e o módulo de elasticidade variou de 112,12 a 140,77  GPa (média  = 134,33). O coeficiente de rugosidade médio (DP) no cone foi de 0,60  (0,03) μm; na região jateada de 12,2 (0,8) μm e na ponta de 0,41 (0,01) μm. Nos ensaios de fadiga e de corrosão não foram observadas alterações. A análisegranulométrica do pó do material depositado demonstrou predominância de partículas médias (75  μm a 180  μm; 84%). A espessura da camada do material depositado apresentou valor médio de 52,7  μm (0 a 318  μm), porosidade média de 16% (variandode 3% a 41%), poros de diâmetro médio de 88,5  μm e profundidade média de 28,2  μm. A tensão (força por unidade de área) de adesão da camada porosa depositada revelou valoresde 15 a 17  MPa. Em conclusão, os resultados dos testes e ensaios técnicos estão dentro das normas internacionalmente recomendadas e padronizadas para implantes metálicos em titânio estando essa prótese de acordo com os padrões internacionaisde qualidade e segurança.


The objective of this work was to study the feasibility of manufacturing a cementless femoral prosthesis in Brazil, in compliance with internationalstandards of quality assurance. A virtual prototype by the Finite Elements Model in AutoCad® 2000 was assessed and demonstrated a von Mises tension 8.1 below the deformation point. In determining the metallic components, the percentages were Fe  = 0.06%, Al  = 6.20%, V  = 3.57%, O  = 0.115%, N  = 0.003%, H  = 0.010% without any contamination due to heavy metals. The elasto-plastic properties showed an average value of hardness of 4.45 (3.92 to 4.79) GPa and elasticity module varied from 112.12 to 140.77  GPa (mean  = 134.33). The average coefficient of roughness (SD) in the cone was 0.60 (0.03) μm, 12.2 (0.8) μm in the plasma spray coating region, and 0.41 (0.01) μm in the tip. In the assays for fatigue and corrosion no changes were observed. The grain size analysis of the deposited material dust demonstrated predominantly (84%) medium size particles (75  μm to 180  μm). The thickness of the deposited material layer presented average value of 52.7  μm (0 to 318  μm), average porosity of 16% (varying from 3% to 41%) and pores of average diameterof 88.5  μm and average depth of 28.2  μm. The force of adhesion of the deposited porous layer showed values between 15  and  17  MPa. Results were in accordance with the norms and tests internationally recommended and standardized for metallic implants in titanium alloy and  the femoral prosthesis manufactured with national technology was in accordance with international standards of design, quality and safeness.


Subject(s)
Prostheses and Implants , Arthroplasty, Replacement, Hip/trends , Materials Testing/instrumentation , Materials Testing/methods , Biomechanical Phenomena/methods , Quality Control , Femur , Biocompatible Materials/therapeutic use , Biomedical Technology/trends , Titanium/therapeutic use