1.
Blood Purif ; 50(2): 180-187, 2021.
Article in English | MEDLINE | ID: mdl-33454709

ABSTRACT

INTRODUCTION: Patients in hemodiafiltration (HDF) eliminate volume overload by ultrafiltration. Vascular volume loss is among the main mechanisms contributing to adverse events such as intradialytic hypotension. Here, we hypothesize that the intradialytic exercise (IDEX) is an intervention that could improve the acute response of physiological mechanisms involved during vascular volume loss. To test this hypothesis, we evaluated the hemodynamic response to mild aerobic exercise during HDF. METHODS: Nineteen end-stage renal disease (ESRD) patients (11 women: 40 ± 10.8 years old, and 8 men: 42 ± 21 years old) receiving HDF thrice a week, with 6 months of previous physical conditioning, participated in this study. Three HDF sessions were scheduled for each patient: 1 resting in supine position, 1 resting in sitting position, and 1 doing aerobic exercise. The first 2 sessions were taken as control. The ultrafiltration rate was set to 800 mL/h in each session. The hemodynamic response was monitored through the relative blood volume (RBV), and cardiovascular variables measured noninvasively by photoplethysmography. Adequacy variables such as Kt/V and percentage reduction of urate, urea, creatinine (Cr), and phosphate were also monitored. FINDINGS: The decrease rate of the RBV was smaller in the session with IDEX compared to the sessions with no exercise. No differences were found neither in the cardiovascular variables nor in the adequacy variables among the 3 sessions. There were no hypotension events during the session with exercise, and 8 events during the sessions without exercise (p = 0.002). DISCUSSION: Mild exercise during HDF decreased the RBV drop and was associated with less hypotension events. The lack of differences in the hemodynamic variables suggests an adequate acute response of cardiovascular compensation variables to intradialytic hypovolemia.


Subject(s)
Blood Volume , Exercise , Hemodiafiltration , Kidney Failure, Chronic/therapy , Adult , Female , Hemodiafiltration/adverse effects , Hemodiafiltration/methods , Hemodynamics , Humans , Hypotension/etiology , Kidney Failure, Chronic/blood , Male , Middle Aged , Prospective Studies , Young Adult
2.
Cancers (Basel) ; 12(11)2020 Nov 18.
Article in English | MEDLINE | ID: mdl-33217988

ABSTRACT

The aim of this work was to systematically obtain quantitative imaging parameters with static and dynamic contrast-enhanced (CE) X-ray imaging techniques and to evaluate their correlation with histological biomarkers of angiogenesis in a subcutaneous C6 glioma model. Enhancement (E), iodine concentration (CI), and relative blood volume (rBV) were quantified from single- and dual-energy (SE and DE, respectively) micro-computed tomography (micro-CT) images, while rBV and volume transfer constant (Ktrans) were quantified from dynamic contrast-enhanced (DCE) planar images. CI and rBV allowed a better discernment of tumor regions from muscle than E in SE and DE images, while no significant differences were found for rBV and Ktrans in DCE images. An agreement was found in rBV for muscle quantified with the different imaging protocols, and in CI and E quantified with SE and DE protocols. Significant strong correlations (Pearson r > 0.7, p < 0.05) were found between a set of imaging parameters in SE images and histological biomarkers: E and CI in tumor periphery were associated with microvessel density (MVD) and necrosis, E and CI in the complete tumor with MVD, and rBV in the tumor periphery with MVD. In conclusion, quantitative imaging parameters obtained in SE micro-CT images could be used to characterize angiogenesis and necrosis in the subcutaneous C6 glioma model.

SELECTION OF CITATIONS
SEARCH DETAIL