Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 27
Filter
1.
Rev. Ciênc. Agrovet. (Online) ; 19(3): 348-353, Set. 2020. tab
Article in Portuguese | VETINDEX | ID: biblio-1488412

ABSTRACT

The objective of this work was to analyze the physical attributes of a Oxisol of different crop-livestock-forest integration systems implanted in 2012 and in use since then. The experimental design was a randomized complete block design, with four replications and four treatments: ILP - crop - livestock integration; ILPF 1L - agrosilvopastoral system, with one eucalyptus line; ILPF 3L - agrosilvopastoral system, with three eucalyptus lines; and EUC - exclusive plantation of eucalyptus (forest). From June 2017 to May 2018, mechanical penetration and gravimetric soil moisture evaluations were carried out to monitor soil compaction in three depths of soil: 0-0.05; 0.05-0.10 and 0.10-0.20 m. The results of the research show that there was a significant difference in the soil attributes studied, being the highest compaction found in the treatment ILPF 3L (0.05-0.10 m) near the limit considered ideal for a good development of the plants. Gravimetric soil moisture did not influence compaction results. In general, the results show that in the soil conditions of the region considered fragile and highly susceptible to compaction, the presence of the animals does not cause a very drastic compaction to the soil, with values lower than the critical limit of 2 MPa.


O objetivo deste trabalho foi analisar os atributos físicos de um Latossolo Vermelho Amarelo de diferentes sistemas de integração lavoura-pecuária-floresta implantados em 2012 e em uso desde então. O delineamento experimental utilizado foi em blocos casualizados, com quatro repetições e quatro tratamentos: ILP - integração lavoura-pecuária; ILPF 1L - sistema agrossilvipastoril, com uma linha de eucalipto; ILPF 3L - sistema agrossilvipastoril, com três linhas de eucalipto; e EUC - plantio exclusivo de eucalipto (bosque). No período de junho de 2017 a maio de 2018 foram realizadas avaliações da resistência mecânica à penetração e da umidade gravimétrica do solo, a fim de monitorar a compactação, em três camadas do solo: 0-0,05; 0,05-0,10 e 0,10-0,20 m de profundidade. Os resultados mostram que houve diferença significativa para os atributos do solo estudados, sendo a maior compactação encontrada no tratamento ILPF 3L (0,05-0,10 m) próximo ao limite considerado ideal para um bom desenvolvimento das plantas. A umidade gravimétrica do solo não influenciou os resultados de compactação. De modo geral, os resultados mostram que a presença dos animais não causa uma compactação muito drástica ao solo, com valores menores que o limite crítico de 2 MPa.


Subject(s)
Soil Analysis , Soil Biology/analysis , Systems Integration , Animal Husbandry , Forests
2.
R. Ci. agrovet. ; 19(3): 348-353, Set. 2020. tab
Article in Portuguese | VETINDEX | ID: vti-27467

ABSTRACT

The objective of this work was to analyze the physical attributes of a Oxisol of different crop-livestock-forest integration systems implanted in 2012 and in use since then. The experimental design was a randomized complete block design, with four replications and four treatments: ILP - crop - livestock integration; ILPF 1L - agrosilvopastoral system, with one eucalyptus line; ILPF 3L - agrosilvopastoral system, with three eucalyptus lines; and EUC - exclusive plantation of eucalyptus (forest). From June 2017 to May 2018, mechanical penetration and gravimetric soil moisture evaluations were carried out to monitor soil compaction in three depths of soil: 0-0.05; 0.05-0.10 and 0.10-0.20 m. The results of the research show that there was a significant difference in the soil attributes studied, being the highest compaction found in the treatment ILPF 3L (0.05-0.10 m) near the limit considered ideal for a good development of the plants. Gravimetric soil moisture did not influence compaction results. In general, the results show that in the soil conditions of the region considered fragile and highly susceptible to compaction, the presence of the animals does not cause a very drastic compaction to the soil, with values lower than the critical limit of 2 MPa.(AU)


O objetivo deste trabalho foi analisar os atributos físicos de um Latossolo Vermelho Amarelo de diferentes sistemas de integração lavoura-pecuária-floresta implantados em 2012 e em uso desde então. O delineamento experimental utilizado foi em blocos casualizados, com quatro repetições e quatro tratamentos: ILP - integração lavoura-pecuária; ILPF 1L - sistema agrossilvipastoril, com uma linha de eucalipto; ILPF 3L - sistema agrossilvipastoril, com três linhas de eucalipto; e EUC - plantio exclusivo de eucalipto (bosque). No período de junho de 2017 a maio de 2018 foram realizadas avaliações da resistência mecânica à penetração e da umidade gravimétrica do solo, a fim de monitorar a compactação, em três camadas do solo: 0-0,05; 0,05-0,10 e 0,10-0,20 m de profundidade. Os resultados mostram que houve diferença significativa para os atributos do solo estudados, sendo a maior compactação encontrada no tratamento ILPF 3L (0,05-0,10 m) próximo ao limite considerado ideal para um bom desenvolvimento das plantas. A umidade gravimétrica do solo não influenciou os resultados de compactação. De modo geral, os resultados mostram que a presença dos animais não causa uma compactação muito drástica ao solo, com valores menores que o limite crítico de 2 MPa.(AU)


Subject(s)
Soil Analysis , Soil Biology/analysis , Systems Integration , Forests , Animal Husbandry
3.
Pesqui. vet. bras ; Pesqui. vet. bras;37(1): 91-96, jan. 2017. ilus., tab., graf.
Article in Portuguese | LILACS, VETINDEX | ID: biblio-846424

ABSTRACT

As afecções ortopédicas com perda de tecido ósseo são um desafio tanto na medicina veterinária quanto na medicina humana. Portanto, não é raro ortopedistas se depararem com fraturas cominutivas irredutíveis de ossos longos, neoplasias ósseas ou não-uniões, que necessitam de procedimentos cirúrgicos reparadores, por meio da substituição de segmento ou preenchimento de falha óssea com o uso de biomateriais. Pretende-se com esta pesquisa avaliar e comparar a resistência mecânica entre biomateriais naturais, sintéticos e mistos. Foram utilizados sete grupos experimentais compostos por seis corpos de provas cada: Grupo 1 , tecido ósseo cortical de coelho (OSSO - controle); Grupo 2, cimento ósseo (CO); Grupo 3, cimento ósseo autoclavado (COA); Grupo 4, cimento ósseo e macrofragmento ósseo cortical de cão (COMaFO); Grupo 5, cimento ósseo e macrofragmento ósseo autoclavado de cortical de cão (COMaFOA); Grupo 6, cimento ósseo e microfragmento ósseo cortical de cão (COMiFO) e Grupo 7, cimento ósseo e microfragmento ósseo cortical de cão (COMiFOA). Os corpos de prova foram submetidos a ensaios mecânicos de compressão axial controlada em máquina universal de ensaio Emic®. O teste era interrompido quando ocorria queda brusca na curva do gráfico indicando falência da amostra. Em relação à Força máxima, os grupos COA, COMaFOA e COMiFOA não diferiram estatisticamente do grupo controle (OSSO; p>0,01). Já os grupos CO, COMaFO e COMiFO diferiram estatisticamente do grupo controle (OSSO; p<0,01). Quanto a rigidez relativa, os grupos COMaFOA e COMiFOA não diferiram estatisticamente do grupo controle (OSSO; p>0,01). Já os grupos CO, COA, COMaFO e COMiFO diferiram estatisticamente do grupo controle (OSSO; p<0,01). Comparando a deformação, os grupos COMaFo, COMaFOA e COMiFO não diferiram estatisticamente do grupo controle (OSSO; p>0,01). Já os grupos CO, COA e COMiFOA diferiram estatisticamente do grupo controle (OSSO; p<0,01). Conclui-se que apenas os grupos COMaFOA e COMiFOA apresentaram propriedades mecânicas muito semelhantes às do grupo controle (OSSO). Por isso, devido a essas características, esses dois biomateriais (COMaFOA e COMiFOA) seriam os mais indicados como substitutos na reparação de falhas ósseas.(AU)


The orthopedic diseases with bone loss are the challenge in both veterinary and human medicine. Therefore, the orthopedist commonly deal with irreducible comminuted fractures of long bones, bone tumors or non-unions, which require repairers surgical procedures, through the segment replacement or bone defect filling with biomaterials. The aim of this research is to evaluate and compare the mechanical strength of natural, synthetic and mixed biomaterials. Seven experimental groups of six test samples each were used: Group 1 rabbit cortical bone (BONE - control); Group 2, bone cement (CO); Group 3, bone cement autoclaved (COA); Group 4, bone cement and dog cortical bone macrofragment (COMaFO); Group 5, bone cement and bone autoclaved macrofragment dog cortical (COMaFOA); Group 6, bone cement and dog cortical bone microfragment (COMIFO) and Group 7, bone cement and dog cortical bone microfragment (COMiFOA). The specimens were subjected to axial compression mechanical tests controlled universal testing machine EMIC®. The test was stopped when there was sharp decline in the graph curve indicating failure of the sample. In relation to the maximum force, the COA groups COMaFOA and COMiFOA not statistically different from the control group (BONE; p> 0.01). Already the CO groups, COMaFO and COMIFO difeririram statistically the control group (BONE; p <0.01). The relative rigidity, the COMaFOA and COMiFOA groups did not differ statistically from the control group (BONE; p>0.01). Already the CO groups, COA, COMaFO and COMIFO differed significantly from the control group (BONE; p<0.01). Comparing the deformation, the COMaFo groups COMaFOA and COMIFO not statistically different from the control group (BONE; p>0.01). Already the CO groups, COA and COMiFOA differed significantly from the control group (BONE; p<0.01). It is concluded that only COMaFOA and COMiFOA groups showed very similar mechanical properties to the control group (BONE). Therefore, due to these characteristics, these two biomaterials (COMaFOA e COMiFOA) would be the most suitable as a substitute in the repair of bone defects.(AU)


Subject(s)
Biocompatible Materials/analysis , Materials Science/analysis , Materials Testing , Orthopedic Equipment
4.
Pesqui. vet. bras ; 37(1): 91-96, jan. 2017. ilus, tab, graf
Article in Portuguese | VETINDEX | ID: vti-686981

ABSTRACT

The orthopedic diseases with bone loss are the challenge in both veterinary and human medicine. Therefore, the orthopedist commonly deal with irreducible comminuted fractures of long bones, bone tumors or non-unions, which require repairers surgical procedures, through the segment replacement or bone defect filling with biomaterials. The aim of this research is to evaluate and compare the mechanical strength of natural, synthetic and mixed biomaterials. Seven experimental groups of six test samples each were used: Group 1 rabbit cortical bone (BONE - control); Group 2, bone cement (CO); Group 3, bone cement autoclaved (COA); Group 4, bone cement and dog cortical bone macrofragment (COMaFO); Group 5, bone cement and bone autoclaved macrofragment dog cortical (COMaFOA); Group 6, bone cement and dog cortical bone microfragment (COMIFO) and Group 7, bone cement and dog cortical bone microfragment (COMiFOA). The specimens were subjected to axial compression mechanical tests controlled universal testing machine EMIC®. The test was stopped when there was sharp decline in the graph curve indicating failure of the sample. In relation to the maximum force, the COA groups COMaFOA and COMiFOA not statistically different from the control group (BONE; p> 0.01). Already the CO groups, COMaFO and COMIFO difeririram statistically the control group (BONE; p < 0.01). The relative rigidity, the COMaFOA and COMiFOA groups did not differ statistically from the control group (BONE; p>0.01). Already the CO groups, COA, COMaFO and COMIFO differed significantly from the control group (BONE; p < 0.01). Comparing the deformation, the COMaFo groups COMaFOA and COMIFO not statistically different from the control group (BONE; p>0.01). Already the CO groups, COA and COMiFOA differed significantly from the control group (BONE; p < 0.01). It is concluded that only COMaFOA and COMiFOA groups showed very similar mechanical properties to [...](AU)


As afecções ortopédicas com perda de tecido ósseo são um desafio tanto na medicina veterinária quanto na medicina humana. Portanto, não é raro ortopedistas se depararem com fraturas cominutivas irredutíveis de ossos longos, neoplasias ósseas ou não-uniões, que necessitam de procedimentos cirúrgicos reparadores, por meio da substituição de segmento ou preenchimento de falha óssea com o uso de biomateriais. Pretende-se com esta pesquisa avaliar e comparar a resistência mecânica entre biomateriais naturais, sintéticos e mistos. Foram utilizados sete grupos experimentais compostos por seis corpos de provas cada: Grupo 1 , tecido ósseo cortical de coelho (OSSO - controle); Grupo 2, cimento ósseo (CO); Grupo 3, cimento ósseo autoclavado (COA); Grupo 4, cimento ósseo e macrofragmento ósseo cortical de cão (COMaFO); Grupo 5, cimento ósseo e macrofragmento ósseo autoclavado de cortical de cão (COMaFOA); Grupo 6, cimento ósseo e microfragmento ósseo cortical de cão (COMiFO) e Grupo 7, cimento ósseo e microfragmento ósseo cortical de cão (COMiFOA). Os corpos de prova foram submetidos a ensaios mecânicos de compressão axial controlada em máquina universal de ensaio Emic®. O teste era interrompido quando ocorria queda brusca na curva do gráfico indicando falência da amostra. Em relação à Força máxima, os grupos COA, COMaFOA e COMiFOA não diferiram estatisticamente do grupo controle (OSSO; p>0,01). Já os grupos CO, COMaFO e COMiFO diferiram estatisticamente do grupo controle (OSSO; p < 0,01). Quanto a rigidez relativa, os grupos COMaFOA e COMiFOA não diferiram estatisticamente do grupo controle (OSSO; p>0,01). Já os grupos CO, COA, COMaFO e COMiFO diferiram estatisticamente do grupo controle (OSSO; p < 0,01). Comparando a deformação, os grupos COMaFo, COMaFOA e COMiFO não diferiram estatisticamente do grupo controle (OSSO; p>0,01). [...](AU)


Subject(s)
Biocompatible Materials/analysis , Materials Science/analysis , Materials Testing , Orthopedic Equipment
5.
Pesqui. vet. bras ; 37(1)2017.
Article in Portuguese | VETINDEX | ID: vti-743605

ABSTRACT

ABSTRACT: The orthopedic diseases with bone loss are the challenge in both veterinary and human medicine. Therefore, the orthopedist commonly deal with irreducible comminuted fractures of long bones, bone tumors or non-unions, which require repairers surgical procedures, through the segment replacement or bone defect filling with biomaterials. The aim of this research is to evaluate and compare the mechanical strength of natural, synthetic and mixed biomaterials. Seven experimental groups of six test samples each were used: Group 1 rabbit cortical bone (BONE - control); Group 2, bone cement (CO); Group 3, bone cement autoclaved (COA); Group 4, bone cement and dog cortical bone macrofragment (COMaFO); Group 5, bone cement and bone autoclaved macrofragment dog cortical (COMaFOA); Group 6, bone cement and dog cortical bone microfragment (COMIFO) and Group 7, bone cement and dog cortical bone microfragment (COMiFOA). The specimens were subjected to axial compression mechanical tests controlled universal testing machine EMIC®. The test was stopped when there was sharp decline in the graph curve indicating failure of the sample. In relation to the maximum force, the COA groups COMaFOA and COMiFOA not statistically different from the control group (BONE; p> 0.01). Already the CO groups, COMaFO and COMIFO difeririram statistically the control group (BONE; p 0.01). The relative rigidity, the COMaFOA and COMiFOA groups did not differ statistically from the control group (BONE; p>0.01). Already the CO groups, COA, COMaFO and COMIFO differed significantly from the control group (BONE; p 0.01). Comparing the deformation, the COMaFo groups COMaFOA and COMIFO not statistically different from the control group (BONE; p>0.01). Already the CO groups, COA and COMiFOA differed significantly from the control group (BONE; p 0.01). It is concluded that only COMaFOA and COMiFOA groups showed very similar mechanical properties to the control group (BONE). Therefore, due to these characteristics, these two biomaterials (COMaFOA e COMiFOA) would be the most suitable as a substitute in the repair of bone defects.


RESUMO: As afecções ortopédicas com perda de tecido ósseo são um desafio tanto na medicina veterinária quanto na medicina humana. Portanto, não é raro ortopedistas se depararem com fraturas cominutivas irredutíveis de ossos longos, neoplasias ósseas ou não-uniões, que necessitam de procedimentos cirúrgicos reparadores, por meio da substituição de segmento ou preenchimento de falha óssea com o uso de biomateriais. Pretende-se com esta pesquisa avaliar e comparar a resistência mecânica entre biomateriais naturais, sintéticos e mistos. Foram utilizados sete grupos experimentais compostos por seis corpos de provas cada: Grupo 1 , tecido ósseo cortical de coelho (OSSO - controle); Grupo 2, cimento ósseo (CO); Grupo 3, cimento ósseo autoclavado (COA); Grupo 4, cimento ósseo e macrofragmento ósseo cortical de cão (COMaFO); Grupo 5, cimento ósseo e macrofragmento ósseo autoclavado de cortical de cão (COMaFOA); Grupo 6, cimento ósseo e microfragmento ósseo cortical de cão (COMiFO) e Grupo 7, cimento ósseo e microfragmento ósseo cortical de cão (COMiFOA). Os corpos de prova foram submetidos a ensaios mecânicos de compressão axial controlada em máquina universal de ensaio Emic®. O teste era interrompido quando ocorria queda brusca na curva do gráfico indicando falência da amostra. Em relação à Força máxima, os grupos COA, COMaFOA e COMiFOA não diferiram estatisticamente do grupo controle (OSSO; p>0,01). Já os grupos CO, COMaFO e COMiFO diferiram estatisticamente do grupo controle (OSSO; p 0,01). Quanto a rigidez relativa, os grupos COMaFOA e COMiFOA não diferiram estatisticamente do grupo controle (OSSO; p>0,01). Já os grupos CO, COA, COMaFO e COMiFO diferiram estatisticamente do grupo controle (OSSO; p 0,01). Comparando a deformação, os grupos COMaFo, COMaFOA e COMiFO não diferiram estatisticamente do grupo controle (OSSO; p>0,01). Já os grupos CO, COA e COMiFOA diferiram estatisticamente do grupo controle (OSSO; p 0,01). Conclui-se que apenas os grupos COMaFOA e COMiFOA apresentaram propriedades mecânicas muito semelhantes às do grupo controle (OSSO). Por isso, devido a essas características, esses dois biomateriais (COMaFOA e COMiFOA) seriam os mais indicados como substitutos na reparação de falhas ósseas.

6.
Biosci. j. (Online) ; 31(6): 1881-1886, nov./dec. 2015.
Article in English | LILACS | ID: biblio-965187

ABSTRACT

The focus of this study was to test the fracture resistance of upper arch dental retainers, made by two different manipulation techniques of acrylic resin. 84 plates Wraparound type retainers were made by two different manipulation techniques forming two groups (n = 42): Group 1 (Addition Technique) and Group 2 (Pressing Technique). All the retainers were duly shaped in U form with the aid of standardized plaster cast models. During the confection process the standardizing of the retainers was conducted carefully regarding their thickness and dimensions with the aid of a gauge and a straight caliper. After confection they remained immersed in water for 24 hours at 37°C. Next, they were tested through mechanical compression until fracture in a universal mechanical testing machine. Data were analyzed by Student's t test. The significance level was set at 5% ( = 0.05). It was found that the average was of 79.12 N for Group 1 and of 77.07 N for Group 2 with a standard deviation of 17.30 N and 16.31, respectively, showing that there is no significant difference in resistance for the retainers when made through any of the two methods (P=0.788). The addition and pressure techniques of acrylic resin do not influence the resistance to compression of the upper dental retainers.


O foco deste estudo foi testar a resistência à fratura de retentores odontológicos do arco superior, feito por duas diferentes técnicas de manipulação de resina acrílica. 84 placas de retentores tipo Wraparound foram feitas por duas diferentes técnicas de manipulação que formam dois grupos (n = 42): Grupo 1 (técnica de adição) e Grupo 2 (técnica de prensagem). Todos os retentores foram devidamente moldado em forma de U, com o auxílio de modelos de gesso padronizados. Durante o processo de confecção a padronização dos retentores foi conduzida cuidadosamente em relação à sua espessura e dimensões, com o auxílio de um medidor e um compasso de calibre linear. Após a confecção eles permaneceram imersos em água por 24 horas a 37 °C. Em seguida, eles foram testados através de compressão mecânica até a fratura em uma máquina universal de ensaios mecânicos. Os dados foram analisados pelo teste t de Student. O nível de significância foi de 5% ( = 0,05). Verificou-se que a média foi de 79,12 N para o Grupo 1 e de 77,07 N para o Grupo 2, com um desvio padrão de 17,30 N e 16,31, respectivamente, indicando que não há diferença significativa na resistência para os retentores, quando feita através de qualquer um dos dois métodos (P = 0,788). As técnicas de adição e pressão de resina acrílica não influenciaram a resistência à compressão dos retentores dentárias superiores.


Subject(s)
Orthodontics , Acrylic Resins , Orthodontic Retainers
7.
Lima; s.n; 2014. 57 p. ilus, tab, graf.
Thesis in Spanish | LIPECS | ID: biblio-1113820

ABSTRACT

Objetivo: Determinar la resistencia mecánica del fijador externo descartable (FED) y del fijador externo reusable (FER) a la compresión axial y flexión. Material y métodos: Se determinó la resistencia a la compresión axial y a la fuerza de flexión del fijador externo descartable en configuración transfixiante y en configuración no transfixiante, y del fijador externo reusable en configuración no transfixiante. Se realizó la prueba en una máquina de ensayos universal en el laboratorio de estructuras antisísmicas de la PUCP, a una velocidad de 2,5 mm/min hasta lograr un desplazamiento a nivel del foco de fractura de 10 mm. Se retiró la fuerza deformante y se evaluó la deformación residual. Finalmente se procedió a una carga de compresión axial en ambos modelos de fijador externo hasta determinar su límite de falla. Resultados: Para 10 mm de desplazamiento axial fueron necesarios 213.49 kg en el fijador externo descartable transfixiante y de 238.12 kg para el fijador externo descartable no transfixiante. El modelo de fijador externo reusable resistió 94.67 kg. La deformación residual fue de 2.95 mm en promedio para el FED transfixiante, 4 mm para el FED no transfixiante y 7.75 mm para el FER. Bajo cargas deflexivas hasta 10 mm de desplazamiento el FED transfixiante resistió 46.69 kg y el FER 152.40 kg. Conclusiones: El FED y FER, en modelos de construcción habitual tienen una resistencia mecánica a las cargas axial y deflexivas similares a otros modelos mundialmente usados, siendo el FED el que mejor resiste la carga axial y el FER la carga en flexión. La estructura que falla en carga máxima en el FED es el cemento y en el FER son los tubos de aluminio.


Objective: To determine the strength of the disposable external fixator (FED) and the reusable external fixator (FER) to axial compression and bending. Material and methods: resistance to axial compression and flexion strength in transfixing disposable external fixator configuration and not transfixing configuration, and reusable external fixation was determined not transfixing configuration. The test was performed in a universal testing machine in the laboratory of aseismic structures of the PUCP, at a speed of 2.5 mm / min until a displacement of the fracture level of 10 rnm. The deforming force was removed and the residual deformation was evaluated. Finally, we proceeded to an axial compressive load in both models to determine their external fixator limit fails. ResuIts: For 10 rnm ofaxial displacement were necessary transfixing 213.49 kg in transfixing disposable external fixator and 238.12 kg for non transfixing disposable external fixator. Reusable external fixator model resisted 94.67 kg. The residual deformation was 2.95 mm on average for the transfixing FED, 4 mm for non transfixing FED and 7.75 rnm for the FER. Under bending loads up to 10 rnm of displacement transfixing FED resisted 46.69 kg and 152.40 kg FER model. Conclusions: The FED and FER in usual construction models have a mechanical resistance to axial loads and similar to other models used worldwide, being the FED which is more resistant to axial load and bending load on FER. The structure failure peak load on the FED is cement and FER are aluminum tubes.


Subject(s)
Mechanical Phenomena , External Fixators , Compressive Strength , Pliability , Longitudinal Studies
8.
Ciênc. rural ; Ciênc. rural (Online);40(5): 1114-1120, maio 2010. graf, ilus, tab
Article in Portuguese | LILACS | ID: lil-552151

ABSTRACT

O presente estudo avaliou a resistência à compressão de meniscos mediais de coelhos da raça Nova Zelândia, por meio de teste mecânico de compressão. Trinta meniscos foram distribuídos em três grupos: grupo MF, composto por dez meniscos frescos; grupo MG, dez meniscos preservados em glicerina 98 por cento, por 30 dias, e grupo MR, dez meniscos preservados em glicerina 98 por cento, por 30 dias e reidratados em NaCl 0,9 por cento, por 12 horas. Os meniscos de cada grupo foram submetidos ao teste de compressão no sentido perpendicular ao seu plano anatômico regular e foram avaliados o limite de elasticidade, a deformação elástica, a tensão ao ponto de ruptura e ao limite de elasticidade e ainda, o índice de rigidez. Os meniscos dos grupos preservados, MG e MR, tiveram o limite elástico semelhante ao grupo de meniscos frescos (MF). O grupo de meniscos em glicerina (MG) apresentou menor capacidade de deformação elástica (P<0,05) que os grupos MF e MR, e maior capacidade de sofrer tensão ao limite elástico. Os meniscos do grupo (MG) apresentaram maior rigidez (P<0,05) que os meniscos dos grupos MF e MR. Conclui-se que o grupo de meniscos preservados em glicerina 98 por cento, seguido de reidratação em NaCl 0,9 por cento (MR), não apresentou alterações significativas na capacidade de resistência ao limite elástico dos meniscos.


The present study evaluated the compressive strength of medial menisci of New Zealand rabbits, through mechanical compression test. Thirty menisci were distributed in three groups: group MF, composed by ten fresh menisci; MG group, composed by ten menisci preserved in 98 percent glycerin for 30 days; and, group MR, ten menisci preserved in 98 percent glycerin for 30 days and rehydrated in NaCl 0.9 percent for 12 hours. The menisci in each group were submitted to compression test in the perpendicular direction to the anatomical plane and had the elasticity limit, the elastic deformity, the rupture stress point and the stiffness index evaluated. The menisci from the preserved groups MG and MR had the elastic limit similar to the fresh menisci group (MF). The group of menisci preserved in glycerin (MG) presented lower elastic deformity capacity (P<0.05) if compared to the other groups, MF and MR, and a higher tension capacity at elastic limit. The menisci from group (MG) presented higher stiffness (P<0.05) than the ones in the MF and MR groups. It can be concluded that the group menisci preserved in glycerin 98 percent followed by rehydration in Nacl 0,9 percent (MR), did not showed any significant alterations in the capacity of the menisci elastic limit.

9.
Ciênc. rural ; Ciênc. rural (Online);40(5): 1097-1102, maio 2010. tab
Article in Portuguese | LILACS | ID: lil-552161

ABSTRACT

A presente pesquisa objetivou caracterizar as propriedades físico-mecânicas da madeira de canafístula (Peltophorum dubium (Spreng.) Taub.) proveniente de árvores com 10 anos, por meio da determinação da massa específica básica, da retratibilidade, do módulo de elasticidade e do módulo de ruptura em flexão estática, do módulo de elasticidade em compressão perpendicular, da resistência máxima à compressão paralela à grã, da dureza de Janka, da resistência máxima ao cisalhamento e da resistência ao choque. A determinação da massa específica básica e da retratibilidade seguiu as normas COPANT 30:1-004 (1971) e 30:1-005 (1971), respectivamente, e os ensaios mecânicos seguiram as normas ASTM D 143-94 (2000) e NF B 51-009 (1942). A massa específica básica e o coeficiente de anisotropia encontrado para a espécie permitiram classificar sua madeira como leve e medianamente estável, respectivamente; já os valores médios das propriedades mecânicas encontradas definem a madeira como de resistência fraca a média. As características tecnológicas determinadas indicam que sua madeira, quando proveniente de plantios jovens, deve ser utilizada com cautela em situações que exijam elevada estabilidade dimensional e resistência mecânica, sendo, portanto, aconselhável seu corte em idades mais avançadas.


This research aimed to characterize the physic-mechanical properties of the canafístula wood (Peltophorum dubium (Spreng.) Taub.) from 10 years' old trees. There was determined the specific gravity, shrinkage, modulus of elasticity and modulus of rupture in static bending, modulus of elasticity in compression perpendicular to the grain, compression strength parallel to the grain, hardness, shear and impact resistance. Specific gravity and shrinkage determination were conducted according to COPANT 30:1:004 (1971) and 30:1-005 (1971), respectively, and the mechanical tests followed ASTM D 143-94 (2000) and NF B51-009 (1942). The specific gravity and the ratio of tangential to radial shrinkage observed, ranked the wood as light and moderately stable, respectively, since the average values of mechanical properties classified the wood as weak to average strength. The technological characteristics observed indicate that when the wood is originated from short rotation plantation, it should be used with caution in situation which requires high dimensional stability and mechanical strength, suggesting the need of older trees.

10.
Sci. agric. ; 67(6)2010.
Article in English | VETINDEX | ID: vti-440529

ABSTRACT

Plant soil compaction poses a serious problem to agriculture because it produces different types of changes in plant characteristics. No method has been implemented to date to use root morphological changes as indicators of soil compaction levels. Therefore, the aim of the present study was to evaluate whether or not the morphological changes in root apexes of soybean (Glycine max (L.) Merrill) can be used as indicators of soil compaction levels. To this end, a silt-loamy soil material (from a Typic Argiudoll, Esperanza series), sieved through a 2 mm mesh was used and the following soil bulk density levels were determined: 1.1, 1.3 and 1.5 g cm³ for which the corresponding mechanical resistances were 0.1, 0.5 and 3.5 MPa, respectively. The distance from the apex to the first tertiary root and the root diameter at 1.5 cm from the apex were measured on the secondary root apexes. A form factor equal to the quotient between these two variables was subsequently calculated. An inverse relationship between soil mechanical impedance and secondary root length and form factor as well as a direct relationship with the secondary root diameter were observed. Changes in rhizodermis cells were also recorded. The following morphological characteristics were found to evidence the highest sensitivity to soil compaction: i) the form factor, ii) rhizodermis papillose cells, iii) apical malformations in root hairs, and iv) root diameter in expansion areas. Taken together, the morphological characteristics of root apexes could be considered to be indicative of soil compaction.


A compactação do solo causa severos problemas devido a que gera diferentes mudanças nas características das plantas. Não existem métodos que possibilitem o uso das mudanças da morfologia das raízes como indicadores de níveis de compactação do solo. Avaliaram-se se alterações morfológicas nos ápices de soja podem ser utilizadas como indicadores de graus de compactação do solo. Solo peneirado a 2 mm, classificado como Typic Argiudol (série Esperanza), foi compactado até atingir os seguintes valores de densidade do solo: 1.1, 1.3 e 1.5 g cm³, para os quais corresponderam os valores de resistência mecânica de 0.1, 0.5 e 3.5 MPa, respectivamente. A distância desde o ápice até a primeira raiz terciária e o diâmetro a 1.5 cm desde o ápice foram medidos nas raízes secundarias. Um fator de forma foi calculado fazendo o quociente entre as duas variáveis medidas. Houve uma relação inversa entre o cumprimento da raiz secundaria e fator de forma com a resistência mecânica, e uma relação direta entre esta ultima e o diâmetro das raízes secundárias. Alterações nas células da rizoderme foram determinadas. As seguintes características morfológicas se mostraram muito sensíveis a compactação do solo: i) o fator de forma, ii) as células papilosas da rizoderme, iii) malformações apicais nos pelos das raízes, e iv) diâmetro das raízes em áreas de expansão. As características morfológicas dos ápices das raízes podem ser consideradas indicadores de compactação dos solos.

11.
Ci. Rural ; 40(5)2010.
Article in Portuguese | VETINDEX | ID: vti-706976

ABSTRACT

This research aimed to characterize the physic-mechanical properties of the canafístula wood (Peltophorum dubium (Spreng.) Taub.) from 10 years' old trees. There was determined the specific gravity, shrinkage, modulus of elasticity and modulus of rupture in static bending, modulus of elasticity in compression perpendicular to the grain, compression strength parallel to the grain, hardness, shear and impact resistance. Specific gravity and shrinkage determination were conducted according to COPANT 30:1:004 (1971) and 30:1-005 (1971), respectively, and the mechanical tests followed ASTM D 143-94 (2000) and NF B51-009 (1942). The specific gravity and the ratio of tangential to radial shrinkage observed, ranked the wood as light and moderately stable, respectively, since the average values of mechanical properties classified the wood as weak to average strength. The technological characteristics observed indicate that when the wood is originated from short rotation plantation, it should be used with caution in situation which requires high dimensional stability and mechanical strength, suggesting the need of older trees.


A presente pesquisa objetivou caracterizar as propriedades físico-mecânicas da madeira de canafístula (Peltophorum dubium (Spreng.) Taub.) proveniente de árvores com 10 anos, por meio da determinação da massa específica básica, da retratibilidade, do módulo de elasticidade e do módulo de ruptura em flexão estática, do módulo de elasticidade em compressão perpendicular, da resistência máxima à compressão paralela à grã, da dureza de Janka, da resistência máxima ao cisalhamento e da resistência ao choque. A determinação da massa específica básica e da retratibilidade seguiu as normas COPANT 30:1-004 (1971) e 30:1-005 (1971), respectivamente, e os ensaios mecânicos seguiram as normas ASTM D 143-94 (2000) e NF B 51-009 (1942). A massa específica básica e o coeficiente de anisotropia encontrado para a espécie permitiram classificar sua madeira como leve e medianamente estável, respectivamente; já os valores médios das propriedades mecânicas encontradas definem a madeira como de resistência fraca a média. As características tecnológicas determinadas indicam que sua madeira, quando proveniente de plantios jovens, deve ser utilizada com cautela em situações que exijam elevada estabilidade dimensional e resistência mecânica, sendo, portanto, aconselhável seu corte em idades mais avançadas.

12.
Ci. Rural ; 40(5)2010.
Article in Portuguese | VETINDEX | ID: vti-706635

ABSTRACT

The present study evaluated the compressive strength of medial menisci of New Zealand rabbits, through mechanical compression test. Thirty menisci were distributed in three groups: group MF, composed by ten fresh menisci; MG group, composed by ten menisci preserved in 98% glycerin for 30 days; and, group MR, ten menisci preserved in 98% glycerin for 30 days and rehydrated in NaCl 0.9% for 12 hours. The menisci in each group were submitted to compression test in the perpendicular direction to the anatomical plane and had the elasticity limit, the elastic deformity, the rupture stress point and the stiffness index evaluated. The menisci from the preserved groups MG and MR had the elastic limit similar to the fresh menisci group (MF). The group of menisci preserved in glycerin (MG) presented lower elastic deformity capacity (P 0.05) if compared to the other groups, MF and MR, and a higher tension capacity at elastic limit. The menisci from group (MG) presented higher stiffness (P 0.05) than the ones in the MF and MR groups. It can be concluded that the group menisci preserved in glycerin 98% followed by rehydration in Nacl 0,9% (MR), did not showed any significant alterations in the capacity of the menisci elastic limit.


O presente estudo avaliou a resistência à compressão de meniscos mediais de coelhos da raça Nova Zelândia, por meio de teste mecânico de compressão. Trinta meniscos foram distribuídos em três grupos: grupo MF, composto por dez meniscos frescos; grupo MG, dez meniscos preservados em glicerina 98%, por 30 dias, e grupo MR, dez meniscos preservados em glicerina 98%, por 30 dias e reidratados em NaCl 0,9%, por 12 horas. Os meniscos de cada grupo foram submetidos ao teste de compressão no sentido perpendicular ao seu plano anatômico regular e foram avaliados o limite de elasticidade, a deformação elástica, a tensão ao ponto de ruptura e ao limite de elasticidade e ainda, o índice de rigidez. Os meniscos dos grupos preservados, MG e MR, tiveram o limite elástico semelhante ao grupo de meniscos frescos (MF). O grupo de meniscos em glicerina (MG) apresentou menor capacidade de deformação elástica (P 0,05) que os grupos MF e MR, e maior capacidade de sofrer tensão ao limite elástico. Os meniscos do grupo (MG) apresentaram maior rigidez (P 0,05) que os meniscos dos grupos MF e MR. Conclui-se que o grupo de meniscos preservados em glicerina 98%, seguido de reidratação em NaCl 0,9% (MR), não apresentou alterações significativas na capacidade de resistência ao limite elástico dos meniscos.

13.
Ci. Rural ; 40(5)2010.
Article in Portuguese | VETINDEX | ID: vti-706632

ABSTRACT

This research aimed to characterize the physic-mechanical properties of the canafístula wood (Peltophorum dubium (Spreng.) Taub.) from 10 years' old trees. There was determined the specific gravity, shrinkage, modulus of elasticity and modulus of rupture in static bending, modulus of elasticity in compression perpendicular to the grain, compression strength parallel to the grain, hardness, shear and impact resistance. Specific gravity and shrinkage determination were conducted according to COPANT 30:1:004 (1971) and 30:1-005 (1971), respectively, and the mechanical tests followed ASTM D 143-94 (2000) and NF B51-009 (1942). The specific gravity and the ratio of tangential to radial shrinkage observed, ranked the wood as light and moderately stable, respectively, since the average values of mechanical properties classified the wood as weak to average strength. The technological characteristics observed indicate that when the wood is originated from short rotation plantation, it should be used with caution in situation which requires high dimensional stability and mechanical strength, suggesting the need of older trees.


A presente pesquisa objetivou caracterizar as propriedades físico-mecânicas da madeira de canafístula (Peltophorum dubium (Spreng.) Taub.) proveniente de árvores com 10 anos, por meio da determinação da massa específica básica, da retratibilidade, do módulo de elasticidade e do módulo de ruptura em flexão estática, do módulo de elasticidade em compressão perpendicular, da resistência máxima à compressão paralela à grã, da dureza de Janka, da resistência máxima ao cisalhamento e da resistência ao choque. A determinação da massa específica básica e da retratibilidade seguiu as normas COPANT 30:1-004 (1971) e 30:1-005 (1971), respectivamente, e os ensaios mecânicos seguiram as normas ASTM D 143-94 (2000) e NF B 51-009 (1942). A massa específica básica e o coeficiente de anisotropia encontrado para a espécie permitiram classificar sua madeira como leve e medianamente estável, respectivamente; já os valores médios das propriedades mecânicas encontradas definem a madeira como de resistência fraca a média. As características tecnológicas determinadas indicam que sua madeira, quando proveniente de plantios jovens, deve ser utilizada com cautela em situações que exijam elevada estabilidade dimensional e resistência mecânica, sendo, portanto, aconselhável seu corte em idades mais avançadas.

14.
Article in Portuguese | LILACS-Express | VETINDEX | ID: biblio-1478166

ABSTRACT

This research aimed to characterize the physic-mechanical properties of the canafístula wood (Peltophorum dubium (Spreng.) Taub.) from 10 years' old trees. There was determined the specific gravity, shrinkage, modulus of elasticity and modulus of rupture in static bending, modulus of elasticity in compression perpendicular to the grain, compression strength parallel to the grain, hardness, shear and impact resistance. Specific gravity and shrinkage determination were conducted according to COPANT 30:1:004 (1971) and 30:1-005 (1971), respectively, and the mechanical tests followed ASTM D 143-94 (2000) and NF B51-009 (1942). The specific gravity and the ratio of tangential to radial shrinkage observed, ranked the wood as light and moderately stable, respectively, since the average values of mechanical properties classified the wood as weak to average strength. The technological characteristics observed indicate that when the wood is originated from short rotation plantation, it should be used with caution in situation which requires high dimensional stability and mechanical strength, suggesting the need of older trees.


A presente pesquisa objetivou caracterizar as propriedades físico-mecânicas da madeira de canafístula (Peltophorum dubium (Spreng.) Taub.) proveniente de árvores com 10 anos, por meio da determinação da massa específica básica, da retratibilidade, do módulo de elasticidade e do módulo de ruptura em flexão estática, do módulo de elasticidade em compressão perpendicular, da resistência máxima à compressão paralela à grã, da dureza de Janka, da resistência máxima ao cisalhamento e da resistência ao choque. A determinação da massa específica básica e da retratibilidade seguiu as normas COPANT 30:1-004 (1971) e 30:1-005 (1971), respectivamente, e os ensaios mecânicos seguiram as normas ASTM D 143-94 (2000) e NF B 51-009 (1942). A massa específica básica e o coeficiente de anisotropia encontrado para a espécie permitiram classificar sua madeira como leve e medianamente estável, respectivamente; já os valores médios das propriedades mecânicas encontradas definem a madeira como de resistência fraca a média. As características tecnológicas determinadas indicam que sua madeira, quando proveniente de plantios jovens, deve ser utilizada com cautela em situações que exijam elevada estabilidade dimensional e resistência mecânica, sendo, portanto, aconselhável seu corte em idades mais avançadas.

15.
Article in Portuguese | LILACS-Express | VETINDEX | ID: biblio-1478169

ABSTRACT

The present study evaluated the compressive strength of medial menisci of New Zealand rabbits, through mechanical compression test. Thirty menisci were distributed in three groups: group MF, composed by ten fresh menisci; MG group, composed by ten menisci preserved in 98% glycerin for 30 days; and, group MR, ten menisci preserved in 98% glycerin for 30 days and rehydrated in NaCl 0.9% for 12 hours. The menisci in each group were submitted to compression test in the perpendicular direction to the anatomical plane and had the elasticity limit, the elastic deformity, the rupture stress point and the stiffness index evaluated. The menisci from the preserved groups MG and MR had the elastic limit similar to the fresh menisci group (MF). The group of menisci preserved in glycerin (MG) presented lower elastic deformity capacity (P 0.05) if compared to the other groups, MF and MR, and a higher tension capacity at elastic limit. The menisci from group (MG) presented higher stiffness (P 0.05) than the ones in the MF and MR groups. It can be concluded that the group menisci preserved in glycerin 98% followed by rehydration in Nacl 0,9% (MR), did not showed any significant alterations in the capacity of the menisci elastic limit.


O presente estudo avaliou a resistência à compressão de meniscos mediais de coelhos da raça Nova Zelândia, por meio de teste mecânico de compressão. Trinta meniscos foram distribuídos em três grupos: grupo MF, composto por dez meniscos frescos; grupo MG, dez meniscos preservados em glicerina 98%, por 30 dias, e grupo MR, dez meniscos preservados em glicerina 98%, por 30 dias e reidratados em NaCl 0,9%, por 12 horas. Os meniscos de cada grupo foram submetidos ao teste de compressão no sentido perpendicular ao seu plano anatômico regular e foram avaliados o limite de elasticidade, a deformação elástica, a tensão ao ponto de ruptura e ao limite de elasticidade e ainda, o índice de rigidez. Os meniscos dos grupos preservados, MG e MR, tiveram o limite elástico semelhante ao grupo de meniscos frescos (MF). O grupo de meniscos em glicerina (MG) apresentou menor capacidade de deformação elástica (P 0,05) que os grupos MF e MR, e maior capacidade de sofrer tensão ao limite elástico. Os meniscos do grupo (MG) apresentaram maior rigidez (P 0,05) que os meniscos dos grupos MF e MR. Conclui-se que o grupo de meniscos preservados em glicerina 98%, seguido de reidratação em NaCl 0,9% (MR), não apresentou alterações significativas na capacidade de resistência ao limite elástico dos meniscos.

16.
Sci. agric ; 67(6)2010.
Article in English | LILACS-Express | VETINDEX | ID: biblio-1497132

ABSTRACT

Plant soil compaction poses a serious problem to agriculture because it produces different types of changes in plant characteristics. No method has been implemented to date to use root morphological changes as indicators of soil compaction levels. Therefore, the aim of the present study was to evaluate whether or not the morphological changes in root apexes of soybean (Glycine max (L.) Merrill) can be used as indicators of soil compaction levels. To this end, a silt-loamy soil material (from a Typic Argiudoll, Esperanza series), sieved through a 2 mm mesh was used and the following soil bulk density levels were determined: 1.1, 1.3 and 1.5 g cm³ for which the corresponding mechanical resistances were 0.1, 0.5 and 3.5 MPa, respectively. The distance from the apex to the first tertiary root and the root diameter at 1.5 cm from the apex were measured on the secondary root apexes. A form factor equal to the quotient between these two variables was subsequently calculated. An inverse relationship between soil mechanical impedance and secondary root length and form factor as well as a direct relationship with the secondary root diameter were observed. Changes in rhizodermis cells were also recorded. The following morphological characteristics were found to evidence the highest sensitivity to soil compaction: i) the form factor, ii) rhizodermis papillose cells, iii) apical malformations in root hairs, and iv) root diameter in expansion areas. Taken together, the morphological characteristics of root apexes could be considered to be indicative of soil compaction.


A compactação do solo causa severos problemas devido a que gera diferentes mudanças nas características das plantas. Não existem métodos que possibilitem o uso das mudanças da morfologia das raízes como indicadores de níveis de compactação do solo. Avaliaram-se se alterações morfológicas nos ápices de soja podem ser utilizadas como indicadores de graus de compactação do solo. Solo peneirado a 2 mm, classificado como Typic Argiudol (série Esperanza), foi compactado até atingir os seguintes valores de densidade do solo: 1.1, 1.3 e 1.5 g cm³, para os quais corresponderam os valores de resistência mecânica de 0.1, 0.5 e 3.5 MPa, respectivamente. A distância desde o ápice até a primeira raiz terciária e o diâmetro a 1.5 cm desde o ápice foram medidos nas raízes secundarias. Um fator de forma foi calculado fazendo o quociente entre as duas variáveis medidas. Houve uma relação inversa entre o cumprimento da raiz secundaria e fator de forma com a resistência mecânica, e uma relação direta entre esta ultima e o diâmetro das raízes secundárias. Alterações nas células da rizoderme foram determinadas. As seguintes características morfológicas se mostraram muito sensíveis a compactação do solo: i) o fator de forma, ii) as células papilosas da rizoderme, iii) malformações apicais nos pelos das raízes, e iv) diâmetro das raízes em áreas de expansão. As características morfológicas dos ápices das raízes podem ser consideradas indicadores de compactação dos solos.

17.
Rev. bras. odontol ; 66(2): 152-155, jul.-dez. 2009. tab
Article in Portuguese | LILACS, BBO - Dentistry | ID: lil-562656

ABSTRACT

Avaliou-se a resistência à flexão de três resinas acrílicas autopolimerizáveis (Dencor®, Duralay™, Pattern ™) nas seguintes condições: imediatamente após a manipulação (mif); imerso em água durante 30 dias (ia) e mistura em partes iguais dos polímeros (mp). Formaram-se nove grupos experimentais (n = 10): I Dencor® mif; II Duralay™ mif; III Pattern™ mif; IV Dencor® ia; V Duralay™ ia; VI Pattern™ ia; VII Dencor®- Pattern™ mp; VIII Dencor®- Duralay™ mp e IX Duralay™ e Pattern™ MP. Realizou-se então um ensaio de flexão em três pontos. A resina Pattern™ e a Dencor® apresentaram maior resistência à flexão. Os resultados submetidos à análise de variância apontaram haver diferença entre os grupos (p = 0,000). Os materiais estudados não cumprem as recomendações da ISO 10477/1998.


Subject(s)
Materials Testing , Physical Phenomena , Acrylic Resins/standards , Dental Prosthesis
18.
Ciênc. rural ; Ciênc. rural (Online);39(2): 467-472, mar.-abr. 2009. ilus
Article in English | LILACS | ID: lil-508107

ABSTRACT

The present study aimed to evaluate a modification of the stabilization method of the tibial tuberosity advancement technique (TTA), originally described for stabilization of the cranial cruciate deficient stifle. Ten adult mongrel dogs with weights ranging from 25 to 30kg were used. After euthanasia, the hind-limbs were divided into two groups: G1 - test (n=10), and G2 - control (n=10) represented by the contra lateral limb. The test group was submitted to the modified TTA technique, stabilized by one shaft screw in craniocaudal position and a titanium cage inserted at the osteotomy site. The position of the patellar tendon, 90º in relation to the tibial plateau, and the correct position of all implants were confirmed radiographically after surgery. Posteriorly, in both groups, limbs were harvested and tibias collected with their respectively patellar tendon insertion preserved for the mechanical resistance test. The fixation of the tibial tuberosity with a shaft screw and titanium cage resulted in resistance compatible with the normal physiological forces transferred to the hind-limbs during locomotion. The biomechanical tests confirmed the viability of the method performed for the tibial tuberosity fixation and support future clinical trials to validate the technique.


O presente estudo teve por objetivo avaliar a resistência mecânica do método de estabilização da técnica de avanço da tuberosidade tibial (TTA), originalmente descrita para tratamento da ruptura do ligamento cruzado cranial. Foram avaliados 10 cães, sem raça definida e com massa corporal entre 25 e 30kg. Após a eutanásia, os membros pélvicos foram divididos em dois grupos, sendo que G1 era o grupo teste (n=10) e G2 o controle (n=10), representado pelo membro contralateral. O grupo operado foi submetido à técnica de avanço da tuberosidade tibial (TTA) modificada, com emprego de um parafuso especial em posição craniocaudal e um espaçador de titânio inserido no local de osteotomia. O posicionamento do tendão patelar perpendicularmente ao platô tibial e o correto posicionamento dos implantes foi confirmado radiograficamente em todos os espécimes. Posteriormente, em ambos os grupos foram coletadas as tíbias, com preservação da inserção dos seus respectivos tendões patelares, para realização dos testes de resistência mecânica. A estabilização da tuberosidade tibial por parafuso especial em sentido craniocaudal e espaçador de titânio demonstrou resistência compatível com as forças fisiológicas tradicionalmente impostas ao membro pélvico durante a locomoção. Os testes biomecânicos confirmam a viabilidade do método de estabilização e sustentam estudos clínicos futuros para validação da técnica cirúrgica.


Subject(s)
Animals , Dogs , Dogs/injuries , Osteotomy/methods , Osteotomy/veterinary , Bone Screws , Bone Screws/veterinary , Tibia/injuries , Titanium/therapeutic use , Biomechanical Phenomena
19.
Rio de Janeiro; s.n; 2009. 91 p. ilus, tab, graf.
Thesis in Portuguese | LILACS, BBO - Dentistry | ID: biblio-866120

ABSTRACT

Na Odontologia, ao se confeccionar peças restauradoras dentárias, pela técnica indireta, o processo mais rotineiramente empregado utiliza um modelo de gesso, obtido a partir de um molde de elastômero, tomado de um dente preparado. Vários fatores podem influenciar na boa precisão de ajustes destas peças como o escoamento do material de vazamento dentro da moldagem, a compatibilidade do material de vazamento com o da moldagem, o tempo de presa, a estabilidade dimensional, a resistência mecânica do material quando da separação moldagem/modelo, a resistência a abrasão e a fidelidade de reprodução de detalhes. Materiais foram introduzidos na odontologia para utilização na confecção de troquéis no intuito de minimizar as desvantagens do gesso, como baixa resistência a abrasão e ligeira expansão de presa. Dentre eles os troquéis metalizados e as resinas epóxicas, que tem vantagens em relação às propriedades mecânicas, porém o primeiro exige técnica demorada e de alto custo e o segundo apresenta contração. O presente trabalho se propõe a testar uma nova composição de poliéster insaturado com estireno adicionado ao carbonato de cálcio em diferentes proporções (10, 20, 30, 40, 50, 60 e 70%) e compará-la ao gesso tipo IV e a resina epoxídica com óxido de alumínio, através de ensaios mecânicos, de abrasão e de alteração dimensional, para avaliar a possibilidade de sua utilização como material de confecção de troquéis para a construção de restaurações indiretas. Para caracterização dos materiais foram feitas análises de espectrometria no infravermelho, Calorimetria de varredura diferencial, termogravimétrica e Microscopia eletrônica de varredura. O compósito a base de poliéster insaturado com 50% de carbonato de cálcio se mostrou viável para utilização como material para troquel. Quando comparado aos materiais de controle mostrou propriedades mecânicas próximas as da resina epoxídica e bem superiores ao gesso, resistência a abrasão superior ao gesso ...


In dentistry, the most commonly used procedure to manufacture indirect dental restorations uses a cast of type IV stone. This cast is made from an elastomeric impression of a prepared tooth. Many factors may influence the accuracy of adaptation of these restorations, such as the flow of the pouring material into the mold, the compatibility between the pouring and the impression materials, the setting time, the dimensional stability, the mechanical strength of the material during the mold / cast separation, the abrasion resistance and fidelity to reproduce details. Materials were introduced for preparing dies in order to minimize the disadvantages of the stone, such as its low resistance to abrasion and slight expansion of setting. These materials include metal-plated dies and epoxy resins, which have advantages concerning mechanical properties. However, the first one has a time-consuming technique and requires high costs while the second material shows shrinkage. This study tested a new composition of unsaturated polyester with styrene added to calcium carbonate in different proportions (10, 20, 30, 40, 50, 60 and 70%) and compared it to the type IV stone and to the epoxy resin with aluminum oxide. This comparison was made by mechanical, abrasion and dimensional changes tests in order to evaluate the possibility of using it as material for dies in the process of construction of indirect restorations. The materials were characterized using the analysis of the infrared spectrometry, differential scanning calorimetry, thermogravimetric and scanning electron microscopy. The composite based on unsaturated polyester with 50% calcium carbonate (P5) was considered viable as material for dies. When it was compared to the control materials the following results were found: a) the mechanical properties of P5 are similar to those ones of the epoxy resin and well above the stone ones; b) the abrasion resistance of this new material is lower in relation to ...


Subject(s)
Calcium Carbonate , Dental Impression Materials , Dental Restoration, Permanent , Polyesters , Calorimetry , Compressive Strength , Mass Spectrometry , Materials Testing , Microscopy, Electron, Scanning , Tensile Strength , Thermogravimetry , Tooth Abrasion
20.
Rio de Janeiro; s.n; 2009. 91 p. ilus, tab, graf.
Thesis in Portuguese | LILACS, BBO - Dentistry | ID: lil-673675

ABSTRACT

Na Odontologia, ao se confeccionar peças restauradoras dentárias, pela técnica indireta, o processo mais rotineiramente empregado utiliza um modelo de gesso, obtido a partir de um molde de elastômero, tomado de um dente preparado. Vários fatores podem influenciar na boa precisão de ajustes destas peças como o escoamento do material de vazamento dentro da moldagem, a compatibilidade do material de vazamento com o da moldagem, o tempo de presa, a estabilidade dimensional, a resistência mecânica do material quando da separação moldagem/modelo, a resistência a abrasão e a fidelidade de reprodução de detalhes. Materiais foram introduzidos na odontologia para utilização na confecção de troquéis no intuito de minimizar as desvantagens do gesso, como baixa resistência a abrasão e ligeira expansão de presa. Dentre eles os troquéis metalizados e as resinas epóxicas, que tem vantagens em relação às propriedades mecânicas, porém o primeiro exige técnica demorada e de alto custo e o segundo apresenta contração. O presente trabalho se propõe a testar uma nova composição de poliéster insaturado com estireno adicionado ao carbonato de cálcio em diferentes proporções (10, 20, 30, 40, 50, 60 e 70%) e compará-la ao gesso tipo IV e a resina epoxídica com óxido de alumínio, através de ensaios mecânicos, de abrasão e de alteração dimensional, para avaliar a possibilidade de sua utilização como material de confecção de troquéis para a construção de restaurações indiretas. Para caracterização dos materiais foram feitas análises de espectrometria no infravermelho, Calorimetria de varredura diferencial, termogravimétrica e Microscopia eletrônica de varredura. O compósito a base de poliéster insaturado com 50% de carbonato de cálcio se mostrou viável para utilização como material para troquel. Quando comparado aos materiais de controle mostrou propriedades mecânicas próximas as da resina epoxídica e bem superiores ao gesso, resistência a abrasão superior ao gesso...


In dentistry, the most commonly used procedure to manufacture indirect dental restorations uses a cast of type IV stone. This cast is made from an elastomeric impression of a prepared tooth. Many factors may influence the accuracy of adaptation of these restorations, such as the flow of the pouring material into the mold, the compatibility between the pouring and the impression materials, the setting time, the dimensional stability, the mechanical strength of the material during the mold / cast separation, the abrasion resistance and fidelity to reproduce details. Materials were introduced for preparing dies in order to minimize the disadvantages of the stone, such as its low resistance to abrasion and slight expansion of setting. These materials include metal-plated dies and epoxy resins, which have advantages concerning mechanical properties. However, the first one has a time-consuming technique and requires high costs while the second material shows shrinkage. This study tested a new composition of unsaturated polyester with styrene added to calcium carbonate in different proportions (10, 20, 30, 40, 50, 60 and 70%) and compared it to the type IV stone and to the epoxy resin with aluminum oxide. This comparison was made by mechanical, abrasion and dimensional changes tests in order to evaluate the possibility of using it as material for dies in the process of construction of indirect restorations. The materials were characterized using the analysis of the infrared spectrometry, differential scanning calorimetry, thermogravimetric and scanning electron microscopy. The composite based on unsaturated polyester with 50% calcium carbonate (P5) was considered viable as material for dies. When it was compared to the control materials the following results were found: a) the mechanical properties of P5 are similar to those ones of the epoxy resin and well above the stone ones; b) the abrasion resistance of this new material is lower in relation to...


Subject(s)
Calcium Carbonate , Dental Impression Materials , Dental Restoration, Permanent , Polyesters , Calorimetry , Compressive Strength , Mass Spectrometry , Materials Testing , Microscopy, Electron, Scanning , Tensile Strength , Thermogravimetry , Tooth Abrasion
SELECTION OF CITATIONS
SEARCH DETAIL