ABSTRACT
This article developed a novel electrochemical immunosensor for the specific detection of aflatoxin B1 (AFB1). Amino-functionalized iron oxide nanoparticles (Fe3 O4 -NH2 ) were synthesized. Fe3 O4 -NH2 were chemically bound on self-assembly monolayers (SAMs) of mercaptobenzoic acid (MBA). Finally, polyclonal antibodies (pAb) were immobilized on Fe3 O4 -NH2 -MBA. The sensor system was evaluated through atomic force microscopy (AFM), cyclic voltammetry (CV), and electrochemical impedance spectroscopy (EIS). A reduction in the anodic and cathodic peak currents was observed after the assembly of the sensor platform. The charge transfer resistance (Rct ) was increased due to the electrically insulating bioconjugates. Then, the specific interaction between the sensor platform and AFB1 blocks the electron transfer of the [Fe(CN)6 ]3-/4- redox pair. The nanoimmunosensor showed a linear response range estimated from 0.5 to 30 µg/mL with a limit of detection (LOD) of 9.47 µg/mL and a limit of quantification (LOQ) of 28.72 µg/mL for AFB1 identification in a purified sample. In addition, a LOD of 3.79 µg/mL, a LOQ of 11.48 µg/mL, and a regression coefficient of 0.9891 were estimated for biodetection tests on peanut samples. The proposed immunosensor represents a simple alternative, successfully applied in detecting AFB1 in peanuts, and therefore, represents a valuable tool for ensuring food safety.
Subject(s)
Arachis , Biosensing Techniques , Aflatoxin B1/analysis , Aflatoxin B1/chemistry , Biosensing Techniques/methods , Electrochemical Techniques/methods , Immunoassay , Limit of Detection , Gold/chemistryABSTRACT
Abstract Lipoprotein monitoring is desirable in the management of medical conditions such as atherosclerotic cardiovascular disease and coronary artery disease, in which controlling the concentration of these chylomicrons is crucial. Current clinical methods are complex and present poor reproducibility between laboratories. For these reasons, recent guidelines discard the assessment of low-density lipoprotein cholesterol (LDL-C) as a routine analysis during lipid-lowering therapies. Concerning the importance of monitoring this parameter, the authors present an electrochemical immunosensor constructed from a simple and easy-to-reproduce platform that allows detecting and quantifying LDL nanoparticles directly from human serum samples. The performance of the biosensor was studied by scanning electron microscopy, cyclic voltammetry, and electrochemical impedance spectroscopy. The biosensing platform displays good stability and linearity between 30 mg dL-1 and 135 mg dL-1 with a detection limit of 20 mg dL-1. The proposed biosensor can be easily employed for monitoring LDL concentration in clinical treatments.
Subject(s)
Phase Transition , Lipoproteins, LDL/analysis , Microscopy, Electron, Scanning/methods , Electrochemistry/instrumentation , Dielectric Spectroscopy/methods , Hypercholesterolemia/classificationABSTRACT
In this work, we present an electrochemical study of the boron cage monomercaptoundecahydro-closo-dodecaborate [B12H11SH]2- in solution and in a self-assembled monolayer over a polycrystalline gold electrode. Cyclic voltammetry of the anion [B12H11SH]2- in solution showed a shift in the peak potentials related to the redox processes of gold hydroxides, which evidences the interaction between the boron cage and the gold surface. For an Au electrode modified with the anion [B12H11SH]2-, cyclic voltammetry response of the probe Fe(CN)63-/Fe(CN)64- showed a ΔEp value typical for a surface modification. Electrochemical impedance spectroscopy presented Rtc and Cdl values related to the formation of a self-assembled monolayer (SAM). A comparison of electrochemical responses of a modified electrode with thioglycolic acid (TGA) reveals that the boron cage [B12H11SH]2- diminishes the actives sites over the Au surface due to the steric effects. Differential capacitance measurements for bare gold electrode and those modified with [B12H11SH]2- and (TGA), indicate that bulky thiols enhance charge accumulation at the electrode-solution interface. In addition to electrochemical experiments, DFT calculations and surface plasmon resonance measurements (SPR) were carried out to obtain quantum chemical descriptors and to evaluate the molecular length and the dielectric constant of the Boron cage. From SPR experiments, the adsorption kinetics of [B12H11SH]2- were studied. The data fit for a Langmuir kinetic equation, typical for the formation of a monolayer.
Subject(s)
Boron , Gold , Boron Compounds , Electrodes , Gold/chemistry , Surface Plasmon ResonanceABSTRACT
In order to obtain gold electrode surfaces modified with Human Papillomavirus L1 protein (HPV L1)-derived peptides, two sequences, SPINNTKPHEAR and YIK, were chosen. Both have been recognized by means of sera from patients infected with HPV. The molecules, Fc-Ahx-SPINNTKPHEAR, Ac-C-Ahx-(Fc)KSPINNTKPHEAR, Ac-C-Ahx-SPINNTKPHEAR(Fc)K, C-Ahx-SPINNTKPHEAR, and (YIK)2-Ahx-C, were designed, synthesized, and characterized. Our results suggest that peptides derived from the SPINNTKPHEAR sequence, containing ferrocene and cysteine residues, are not stable and not adequate for electrode surface modification. The surface of polycrystalline gold electrodes was modified with the peptides C-Ahx-SPINNTKPHEAR or (YIK)2-Ahx-C through self-assembly. The modified polycrystalline gold electrodes were characterized via infrared spectroscopy and electrochemical measurements. The thermodynamic parameters, surface coverage factor, and medium pH effect were determined for these surfaces. The results indicate that surface modification depends on the peptide sequence (length, amino acid composition, polyvalence, etc.). The influence of antipeptide antibodies on the voltammetric response of the modified electrode was evaluated by comparing results obtained with pre-immune and post-immune serum samples.
Subject(s)
Capsid Proteins/chemistry , Drug Design , Electrodes , Gold , Oncogene Proteins, Viral/chemistry , Peptides/chemistry , Amino Acid Sequence , Animals , Gold/chemistry , Molecular Structure , Peptides/chemical synthesis , Protein Stability , Rabbits , Spectroscopy, Fourier Transform Infrared , ThermodynamicsABSTRACT
Magneto-elastic biosensors have mass sensitivity to biological species, offering reliability and reproducibility in the detection of pathogens such as Escherichia coli. In this work, amorphous ribbons of Metglas 2826MB3 were coated with layers of Cr and Au by DC magnetron sputtering and cut to 5mm×1mm. The influence of different thiols on captured pathogens was studied. The compounds cystamine (CYS), cysteamine (CYSTE) and mercaptopropionic acid (MPA) were deposited on Au-covered surfaces, followed by antibodies. The roughness parameters Ra and Rq were determined using atomic force microscopy (AFM) and micrographs from scanning electron microscopy with a field emission gun (FESEM) were also utilized. Biosensors formed with MPA showed an increased efficiency for attracting E. coli compared to biosensors with CYS and CYSTE, but large standard deviations were observed, making reproducibility and reliability difficult for that biosensor. Sensors tested with CYSTE showed greater efficiency and a lower detection limit than sensors with CYS. The results indicated that the size of the carbon chain and the terminal grouping influence the effectiveness of immobilization on magneto-elastic biosensors.
Subject(s)
Biosensing Techniques/methods , Escherichia coli/metabolism , Magnetic Fields , Sulfhydryl Compounds/analysis , Escherichia coli/cytologyABSTRACT
A capacitive biosensor was used for detection of aflatoxin B1. Two different methods for cleaning gold electrodes were evaluated using cyclic voltammetry in the presence of ferricyanide as redox couple. The methods involve use of a sequence of cleaning steps avoiding the use of Piranha solution and plasma cleaner. Anti-aflatoxin B1 was immobilized on self-assembled monolayers (SAM). The immune-capacitive biosensor is able to detect aflatoxin B1 concentrations in a linear range of 3.2 × 10-12 M to 3.2 × 10-9 M when thiourea was used to form the SAM; 3.2 × 10-9 M to 3.2 × 10-7 M when thioctic acid was used. When the gold surface was isolated with tyramine-electropolymerization linear ranges of 3.2 × 10-13 M to 3.2 × 10-7 M and 3.2 × 10-9 M to 3.2 × 10-7 M where obtained, respectively. The results obtained show the difference in linear range, limit of detection, and limit of quantification when different self-assembled monolayers are used for aflatoxin B1 detection.