Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 13 de 13
Filter
1.
J Pediatr Surg ; 59(5): 956-961, 2024 May.
Article in English | MEDLINE | ID: mdl-38016849

ABSTRACT

BACKGROUND: Metal allergy following placement of a metal pectus bar for minimally invasive repair of pectus excavatum (MIRPE) is a rare complication with potentially significant morbidity. There is no consensus regarding preoperative metal allergy testing (MAT). This study aims to assess incidence of metal allergy and titanium bar use in tested and untested patients and trends in MAT with different approaches to MAT. METHODS: A retrospective chart review was performed on patients who underwent MIRPE from July 2009 to June 2022 at a single institution. During this time, MAT was performed routinely (RT; routine testing) and selectively (ST; selective testing). RESULTS: The cohort included 741 patients for analysis. Metal bar allergy was documented in 1.3 % of all patients; the incidence was 1.3 % in patients with MAT and 1.4 % without MAT. The incidence of bar allergy was 1.1 % in the RT group and 1.6 % in the ST group. In the RT group, bar allergy occurred in 1.4 % (3/216) of patients with a negative MAT. In the ST group, bar allergy occurred in 1.2 % (2/164) of patients with a negative MAT and in 1.9 % (3/162) of untested patients with a stainless-steel bar. Titanium bar use was not significantly different between the RT and ST groups (18.3 % vs 16.3 %, p > 0.05). CONCLUSION: The incidence of metal bar allergy after MIRPE was less than 2 %, and titanium bar use was not significantly different in routine and selective testing groups. MAT was not associated with a reduction in bar allergy, and its use remains unsupported. LEVEL OF EVIDENCE: III.

2.
Arthroplast Today ; 18: 138-142, 2022 Dec.
Article in English | MEDLINE | ID: mdl-36345325

ABSTRACT

Background: Metal allergy testing may influence clinical decision-making for patients undergoing a total knee arthroplasty (TKA). Limited data were found to examine the consistency of available testing modalities. This study compares different metal allergy test results and clinical outcomes after primary and revision TKAs in patients with and without metal hypersensitivity. Methods: Primary (n = 28) and revision (n = 20) TKA patients receiving hypoallergenic implants for metal allergies diagnosed by skin patch testing (SPT), lymphocyte proliferation testing (LPT), or lymphocyte transformation testing (LTT) were retrospectively reviewed. The agreement between tests was assessed by percentage and kappa statistic within patients who used multiple testing modalities. Postoperative clinical outcomes of these patients were compared to those of patients without metal hypersensitivity matched by age (±5 years), body mass index (±5), gender, and follow-up duration (±2 years). Results: SPT and LPT showed weak agreement for nickel and minimal agreement for cobalt. SPT and LTT showed minimal agreement for nickel; weak agreement for titanium, bone cement, vanadium, and zirconium; but strong agreement for chromium and cobalt. LPT and LTT agreement was weak. Compared to matched controls, metal hypersensitivity patients undergoing primary TKAs with hypoallergenic implants experienced less improvement in Knee Society Scores, Veterans RAND 12 physical component scores, and range of motion. Patients undergoing revision TKAs for multiple indications including metal hypersensitivity had worse clinical outcomes with significantly worse improvements in Knee Society functional scores compared to matched controls. Conclusions: Metal allergy tests produce conflicting results. Hypersensitivity patients may experience inferior clinical outcomes even with hypoallergenic implants. Clinician awareness may influence the choice of testing and improve preoperative counseling of this patient population.

3.
J Oral Maxillofac Pathol ; 26(2): 242-253, 2022.
Article in English | MEDLINE | ID: mdl-35968162

ABSTRACT

Sarcoidosis is a granulomatous disorder of multiple organs, with lungs and lymphatic systems being the most frequently affected sites of the body. It was first reported in 1877 and has continued to engross both clinicians and scientists since that time. Because sarcoidosis being a diagnosis of exclusion, it demands the physician to rule out all the possible diagnosis. Most of the patients remain asymptomatic and this makes the disease remain unnoticed for a prolonged period. Later after years, the disease could be diagnosed after witnessing the patient being symptomatic or suffering from organ failures. It could affect middle aged people of any sexes, often its clinical features correlate with tuberculosis. On immunological and histopathological examination, it reveals noncaseating granuloma in simple terms. Glucocorticoids remain the standard drug now and then. Further research has to be done to know the exact pathogenesis, early detection and betterment in treatment plan of sarcoidosis. The current review article gives a brief knowledge about etiopathogenesis, Clinical features, upgraded diagnostic methods such as biomarkers detection and the organized treatment plan to treat sarcoidosis.

4.
J Dent Sci ; 17(3): 1300-1306, 2022 Jul.
Article in English | MEDLINE | ID: mdl-35784139

ABSTRACT

Background/ purpose: Distinguishing oral lichenoid contact lesions (OLCLs) from oral lichen planus (OLP) is challenging. This study aimed to identify clinicopathological findings to distinguish OLCLs from OLP, and to evaluate the effectiveness of removing metal allergens in the treatment of OLCLs. Materials and methods: This study retrospectively evaluated 30 patients diagnosed with OLCLs, and 30 age- and sex-matched OLP patients. We also evaluated the effectiveness of removing dental metal containing positive metal allergen, confirmed by skin patch test and metal component analysis in patients with OLCLs. Results: Palladium and gold were the most common patch test-positive metals observed in the oral cavity of patients with OLCLs. The patients with OLCLs were more likely to present with white type lesions in the buccal mucosa and gingiva than were the patients with OLP (p = 0.030, 0.009, respectively). Overall, 50.0% of patients with OLCLs failed to meet the histopathological diagnostic criteria of OLP. Twenty-three of 24 (95.8%) patients with OLCLs showed a complete or partial improvement after the removal of dental metal. Conclusion: The present findings suggest the importance of a skin patch test and metal component analysis to confirm suspected OLCLs related to dental metal allergy, as these lesions may improve with the removal of the allergy-inducing metal.

5.
Arerugi ; 71(3): 258, 2022.
Article in Japanese | MEDLINE | ID: mdl-35569950
6.
J Med Microbiol ; 68(9): 1314-1319, 2019 Sep.
Article in English | MEDLINE | ID: mdl-31274404

ABSTRACT

Introduction. Current intradermal tuberculin skin tests for latent tuberculosis infection (LTBI) based on purified protein derivative (PPD) have poor specificity.Aims. Developing a better skin test antigen as well as a simple skin patch test may improve and facilitate diagnostic performance.Methodology. Defined recombinant antigens that were unique to Mycobacterium tuberculosis (MTB), including two potential latency-associated antigens (ESAT-6 and Rv2653c) and five DosR-encoded latency proteins (Rv1996, Rv2031c, Rv2032, DevR and Rv3716c), were used as diagnostic skin test reagents in comparison with a standard PPD. The performance of the skin tests based on the detection of delayed-type hypersensitivity (DTH) reaction in guinea pigs sensitized to MTB and M. bovis bacille Calmette-Guérin (BCG) vaccine was evaluated.Results. The latency antigens Rv1996, Rv2031c, Rv2032 and Rv2653c and the ESAT-6 protein elicited less reactive DTH skin responses in MTB-sensitized guinea pigs than those resulting from PPD, but elicited no response in BCG-vaccinated guinea pigs. The remaining two latency antigens (DevR and Rv3716c) elicited DTH responses in both groups of animals, as did PPD. The reactivity of PPD in BCG-vaccinated guinea pigs was greater than that of any of the selected skin test reagents. Using stronger concentrations of selected skin test reagents in the patch test led to increased DTH responses that were comparable to those elicited by PPD in guinea pigs sensitized with MTB.Conclusion. Transdermal application of defined purified antigens might be a promising method for LTBI screening.


Subject(s)
Hypersensitivity, Delayed/immunology , Latent Tuberculosis/diagnosis , Mycobacterium tuberculosis/immunology , Skin Tests/methods , Transdermal Patch , Animals , Antigens, Bacterial/immunology , BCG Vaccine/immunology , Female , Guinea Pigs , Indicators and Reagents , Mycobacterium tuberculosis/isolation & purification , Skin Tests/standards , Tuberculin/immunology
7.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-509322

ABSTRACT

ABSTRACT:Objective To investigate the distributional characteristics of anaphylactogens in prurigo nodularis (PN)patients so as to provide clinical basis for selecting the method of allergy test.Methods We divided 262 PN patients into four groups and then used skin-prick (5 4 patients ),skin-patch (5 0 patients ),serum IgE allergen detection (56 patients)and serum IgG allergen detection (102 patients)to analyze anaphylactogen positive rate and their distribution differences in PN.Results For skin-prick test in 54 PN patients,the detection rates of platanus orientalis,artemisia argyi,poplar,dust mite,dirt mite,cod,peanut and tomato were higher than those in the control group (P<0.05 ).For skin-patch test in 50 PN patients,the detection rates of nickel sulfate,flavor compounds,black rubber,and carba mix were higher than those in the control group (P<0.05).For serum IgE test in 5 6 PN patients,the detection rates of house dust,scandent hop,cat/dog hair,bug,penicillium/neurospora and mutton were higher than those in the control group (P<0.05).For serum IgG test in 102 PN ones,the detection rates of crab,shrimp,beef and cod were higher than those in the control group (P<0.05).Conclusion Skin-prick test and serum IgE detection have high application values in PN patients.Serum IgG detection is of certain importance in adjusting PN patients’diet structure while skin-patch test applied in PN needs further exploration.

8.
Article in English | MEDLINE | ID: mdl-26962386

ABSTRACT

BACKGROUND: Skin patch test is the gold standard method in diagnosing contact allergy. Although used for more than 100 years, the patch test procedure is performed with variability around the world. A number of factors can influence the test results, namely the quality of reagents used, the timing of the application, the patch test series (allergens/haptens) that have been used for testing, the appropriate interpretation of the skin reactions or the evaluation of the patient's benefit. METHODS: We performed an Internet -based survey with 38 questions covering the educational background of respondents, patch test methods and interpretation. The questionnaire was distributed among all representatives of national member societies of the World Allergy Organization (WAO), and the WAO Junior Members Group. RESULTS: One hundred sixty-nine completed surveys were received from 47 countries. The majority of participants had more than 5 years of clinical practice (61 %) and routinely carried out patch tests (70 %). Both allergists and dermatologists were responsible for carrying out the patch tests. We could observe the use of many different guidelines regardless the geographical distribution. The use of home-made preparations was indicated by 47 % of participants and 73 % of the respondents performed 2 or 3 readings. Most of the responders indicated having patients with adverse reactions, including erythroderma (12 %); however, only 30 % of members completed a consent form before conducting the patch test. DISCUSSION: The heterogeneity of patch test practices may be influenced by the level of awareness of clinical guidelines, different training backgrounds, accessibility to various types of devices, the patch test series (allergens/haptens) used for testing, type of clinical practice (public or private practice, clinical or research-based institution), infrastructure availability, financial/commercial implications and regulations among others. CONCLUSION: There is a lack of a worldwide homogeneity of patch test procedures, and this raises concerns about the need for standardization and harmonization of this important diagnostic procedure.

9.
Intractable Rare Dis Res ; 5(1): 56-7, 2016 Feb.
Article in English | MEDLINE | ID: mdl-26989652

ABSTRACT

Pacemaker contact sensitivity is a rare condition. Less than 30 reports of pacemaker skin reactions have been described. We report a 57-year-old woman who underwent an implantable cardiac defibrillator (ICD) implantation for ventricular tachycardia. A skin patch test was positive on almost all components of the pacemaker system. She was treated with topical corticosteroids and skin lesions resolved within 2 weeks. Because of widespread use of various devices, we will see this more often and therefore it is important to recognize this problem and its effective management.

10.
Biomed Mater Eng ; 26(1-2): 1-8, 2015.
Article in English | MEDLINE | ID: mdl-26484550

ABSTRACT

Metal patch test is often used in clinical settings when metal-induced contact dermatitis is suspected. However, the transdermal permeation behavior of metal ions from the patch test remains unclear. Current patch tests using high concentrations of metal salt solutions have some side effects, e.g. acute skin reactions to high concentrations of metal salt. To resolve these, estimating metal ion transdermal permeation is wished. In this study, synchrotron radiation X-ray fluorescence (SR-XRF) and micro-focused particle-induced X-ray emission (micro-PIXE) were used to visualize the time-dependent Ni permeation in mouse skin. The cross-sectional diffusion of Ni was visualized in a time-dependent manner. Our results indicate that maximum Ni permeation occurs after 24 h of patch treatment, and the permeated Ni content was high in the epidermis and spread into the dermis beyond the basal layer. This method may be useful to determine the appropriate solution concentration and duration of administration for the patch test.


Subject(s)
Nickel/chemistry , Patch Tests/methods , Skin Absorption , Skin/chemistry , Skin/ultrastructure , Spectrometry, X-Ray Emission/methods , Absorption, Physiological , Animals , In Vitro Techniques , Mice , Mice, Inbred C57BL , Microscopy, Fluorescence/methods , Nickel/analysis , Tissue Distribution
11.
Article in Japanese | WPRIM (Western Pacific) | ID: wpr-375247

ABSTRACT

A 58-year-old man who complained of dyspnea on effort was given a diagnosis of decompensated congestive heart failure. Echocardiography revealed severe aortic regurgitation and cardiomegaly. We decided to perform aortic valve replacement with a mechanical valve, however his past history made us suspicious of allergy to metal. From his previous patient records, we determined he was allergic to many metals : gold, iron, platinum, cobalt, chrome, bronze, and zinc. Newly performed skin patch tests showed positive reactions to aluminum, tin, palladium, indium, iridium and stainless steel. We selected a CarboMedics mechanical valve made of nickel-titanium alloy. Aortic valve replacement with a 27-mm CarboMedics mechanical valve was performed by median sternotomy. At sternum closure, we used polyester non-absorbable suture thread, instead of surgical steel wire, because it contains stainless steel. His postoperative progress was good and he was discharged on the 10th postoperative day. One year after surgery he is doing well without any allergic symptoms.

12.
Article in Korean | WPRIM (Western Pacific) | ID: wpr-177608

ABSTRACT

BACKGROUND: Epoxy resin compounds are one of the common causes of occupational allergic contact dermatitis. In Korea, most cases of allergic contact dermatitis from epoxy resin compounds have been caused by the epoxy resin itself. We report a rare case of allergic contact dermatitis which was caused by epichlorohydrin, an ingredient of epoxy resin and 2,4,6-tris-(dimethylaminomethyl)phenol (tris-DMP), a kind of hardeners. CASE REPORT: A 43-year-old man, who had worked at the epoxy resin glue manufacturing factory since 1999, presented with mild and intermittent erythematous papules and rashes on his face, neck, trunk, and both arms. He was dealing with epoxy resin, epichlorohydrin, bisphenol A and hardeners. After a new hardener was added in August 2008, his skin lesions worsened from what he had experienced in the past. A skin patch test was performed to identify the causative chemicals of the skin lesion. Epichlorohydrin and tris-DMP elicited positive reactions after 48 hours and increased after 96 hours. CONCLUSION: This case confirmed occupational allergic contact dermatitis caused by epichlorohydrin and tris-DMP, an ingredient of epoxy resin and a hardener, respectively.


Subject(s)
Adult , Humans , Adhesives , Arm , Benzhydryl Compounds , Dermatitis, Allergic Contact , Epichlorohydrin , Exanthema , Korea , Neck , Patch Tests , Phenols , Skin
13.
Reprod Med Biol ; 7(3): 119-122, 2008 Sep.
Article in English | MEDLINE | ID: mdl-29699292

ABSTRACT

Human seminal plasma allergy in women is uncommon, but causes a variety of serious reactions, including urticaria, dyspnea and vomiting, in those that are affected. Semen barriers, such as condoms, are the most widely advocated method for avoiding these reactions. However, this is not acceptable to couples who wish to have children. We present a case of a woman with human seminal plasma allergy who became pregnant after the eighth cycle of artificial insemination using washed sperm from her spouse. (Reprod Med Biol 2008; 7: 119-122).

SELECTION OF CITATIONS
SEARCH DETAIL
...