1.
Article in English | MEDLINE | ID: mdl-38955627

ABSTRACT

BACKGROUND: There is limited data on cardiac output in patients with small aortic annuli undergoing trans-catheter aortic valve implantation (TAVI) according to the implanted platform of balloon-expandable (BEV) compared to self-expanding valves (SEV). METHODS: This is a retrospective analysis of consecutive patients with severe aortic stenosis and small annuli who underwent successful TAVI. Cardiac output was measured using echocardiography within 4 weeks following TAVI. Data were recorded and analysed by an experienced operator who was not aware of the type of the implanted valve. RESULTS: 138 patients were included in the analysis, of whom 57 % underwent TAVI with BEV. Clinical and echocardiographic characteristics were comparable between the two platforms, except for more frequent previous cardiac surgery and smaller indexed aortic valve in the BEV group. There was no relationship between computed tomography-derived aortic annulus area and cardiac output post TAVI. When compared to patients who underwent TAVI with BEV, those with SEV had larger cardiac output [mean difference - 0.50 l/min, 95 % CI (-0.99, -0.01)] and cardiac index [mean difference - 0.20 l/min/m2, 95 % CI (-0.47, 0.07)], although the latter did not reach statistical significance. Unlike patients with small body surface area, in those with large body surface area both cardiac output and cardiac index were statistically larger in patients who underwent SEV compared to BEV. CONCLUSION: Cardiac output, as measured by echocardiography, was larger in patients with small annuli who underwent TAVI procedure with SEV compared to BEV. Such difference was more evident in patients with large body surface area.

2.
Front Cardiovasc Med ; 10: 1139771, 2023.
Article in English | MEDLINE | ID: mdl-37554367

ABSTRACT

Background: Commando procedure, the surgical replacement of the mitral and aortic valves combined with reconstruction of the fibrosa fibrous body, is a technical challenge in patients with small aortic and mitral annuli. In this study, we evaluated the safety and early outcomes of the "Chimney" modality of the Commando procedure, in patients with small aortic and mitral annuli, after prior valve surgery, using a self-assembled valved conduit. Methods: From April 2021 to April 2022, 30 consecutive cases of the "Chimney" Commando procedure, with a self-assembled valved conduit and other combined cardiac procedures, were fully performed for re-operative patients with small aortic roots. Data were obtained through a medical record review, at the Asian Heart Hospital in Wuhan, China. Results: The patient's mean age was 52.7 ± 13.53 years, with 93.3% females. All patients had a previous heart valve surgery, 90% of which had double valve replacement (DVR). Hospital death occurred in 3.3% (n = 1) of the patients, due to malignant arrhythmias and multiorgan failure. Postoperative echocardiogram exams showed that the sizes of the aortic and mitral valve prostheses were 24.23 ± 1.60 mm and 28.33 ± 1.21 mm, respectively. All patients had intact intervalvular fibrosa (IVF) repair and no patient had any aberration in the left heart chamber communication. With the exception of one postoperative sick sinus syndrome and one re-sternotomy for bleeding, there were no significant postoperative complications, such as mortality, renal failure requiring ongoing dialysis, or mediastinitis. Echocardiography exams in the sixth postoperative month showed that the mean gradients of the aortic and mitral valves were 16.26 ± 6.44 mmHg and 11.24 ± 4.90 mmHg, respectively. Conclusions: In comparison with the standard Commando operation, the early outcomes and safety of the "Chimney" Commando procedure proved to be a feasible therapeutic option for patients with small aortic and mitral annuli, after prior valve operations. This approach enables the enlargement of the aortic and mitral annuli and the implantation of the necessary valve prosthesis.

3.
J Clin Med ; 11(18)2022 Sep 09.
Article in English | MEDLINE | ID: mdl-36142960

ABSTRACT

BACKGROUND: Self-expanding transcatheter valves (THV) seem superior to balloon-expanding valves in regard to the incidence of prosthesis-patient mismatch (PPM). Data on the occurrence of PPM with the ACURATE neo/neo2 system as a representative of self-expanding prostheses in very small annuli, even below the applicable instructions for use (IFU), are scarce. METHODS: Data from 654 patients with severe native aortic stenosis treated with the smallest size ACURATE neo/neo2 valve (size S, 23 mm) at two German high-volume centers from 06/2012 to 12/2021 were evaluated. We compared clinical and hemodynamic outcomes among patients with implantation in adherence to the recommended sizing (on-label n = 529) and below the recommended sizing range (off-label n = 125) and identified predictors for PPM in the overall population. BMI-adjusted PPM was defined according to VARC-3 recommendations. RESULTS: Post-procedure, the mean gradient (10.0 mmHg vs. 9.0 mmHg, p = 0.834) and the rate of paravalvular leakage (PVL) ≥ moderate (3.2% vs. 2.8%, p = 0.770) were similar between on-label and off-label implantations. The rate of moderate to severe PPM (24%) was comparably low in ACURATE neo/neo2 S, with a very low proportion of severe PPM whether implanted off- or on-label (4.9% vs. 3.8%, p = 0.552). Thirty-day all-cause mortality was higher among patients with off-label implantations (6.5% vs. 2.3%, p = 0.036). In the subgroup of these patients, no device-related deaths occurred, and cardiac causes did not differ (each 5). Besides small annulus area and high BMI, a multivariate analysis identified a greater cover index (OR 3.26), deep implantation (OR 2.25) and severe calcification (OR 2.07) as independent predictors of PPM. CONCLUSIONS: The ACURATE neo/neo2 S subgroup shows a convincing hemodynamic outcome according to low mean gradient even outside the previous IFUs without a relevant increase in the rate of PVL or PPM. In addition to known factors such as annulus area and BMI, potential predictors for PPM are severe annulus calcification and implantation depth. Nevertheless, the ACURATE neo/neo2 system seems to be a reliable option in patients with very small annuli.

4.
JTCVS Tech ; 13: 31-39, 2022 Jun.
Article in English | MEDLINE | ID: mdl-35711205

ABSTRACT

Objectives: Management of degenerated bioprosthetic aortic valves remains a challenge. Valve-in-valve transcatheter aortic valve replacement (AVR) has limited utility in the presence of small annuli/prosthetic valves. Sutureless valves may offer an advantage over traditional redo AVR by maximizing effective orifice area due to their unique design as well as ease of implant. Methods: Twenty-two patients undergoing redo AVR received a sutureless valve in our institution over the past 5 years. All patients were determined to be poor candidates for valve-in-valve transcatheter AVR due to a combination of small annulus size, low coronary heights, and/or underlying valve characteristics (ie, mechanical valves). Results: Median time from implant to redo AVR was 8 years. One patient died within 30 days. In the 13 patients who had a 21 mm or smaller valve explanted, 5 small, 7 medium, and 1 large Perceval valves were implanted (all with larger internal diameters than the explanted valve). The average postoperative gradient of the cohort valves was 14.8 mm Hg compared with 38.8 mm Hg preoperatively. Conclusions: In addition to their ease of use and rapid deployment, sutureless bioprosthetic aortic valves offer significant physiological advantages in patients with degenerated prosthetic aortic valves and small anatomical annuli. It can also simplify the surgical approach to redo AVR following a Bentall procedure. If long-term durability is confirmed, sutureless valves should be considered in a broader population of patients for both redo and primary aortic valve replacement surgery.

5.
Data Brief ; 34: 106736, 2021 Feb.
Article in English | MEDLINE | ID: mdl-33506083

ABSTRACT

Experimental data on water vapour adsorption on silica gel in four packed bed configurations namely fully packed bed (FPB), large annulus packed bed (LAPB), medium annulus packed bed (MAPB) and small annulus packed bed (SAPB) are presented. Raw temperature data from designated mass transfer zones (MTZ) in the packed beds and on their corresponding walls are presented along with data of the inlet and outlet moist air conditions. Pressure transducers installed at the inlet and outlet provided pressure data. The presented data also covers the material properties of the silica gel for adsorption obtained through material testing and analysis in the laboratory. With detailed experimental methodology and comprehensive material and water vapour adsorption data, this article can help other researchers to validate and verify the performance of their adsorption systems. The material property data presented can also help investigators to use appropriate experimentally determined property values of silica gel in their theoretical studies. Furthermore, this data can serve as a basis of comparison for heat and mass transfer in other experimental adsorption systems.

6.
Semin Thorac Cardiovasc Surg ; 33(1): 23-30, 2021.
Article in English | MEDLINE | ID: mdl-32439547

ABSTRACT

The concept of prosthesis-patient mismatch (PPM) has gained much attention since first described 40 years ago. Previous studies have shown conflicting evidence regarding increased early and late morbidity and mortality with PPM after aortic valve replacement (AVR). The aim of this study was to evaluate the effects of PPM on short- and long-term mortality in low-risk patients after isolated AVR. A retrospective, single-center study involving 1707 consecutive patients ≤80 years of age with preserved left ventricular systolic function who underwent elective, primary isolated AVR operations from 2008 to 2018. Patients were stratified into 2 groups according to the presence of PPM (n = 96), defined as effective orifice area index <0.85 cm2/m2 body surface area, and no-PPM (n = 1611). The effect of PPM on mortality was evaluated with univariate and multivariate analyses. 30-day mortality was 0.8% (4.2% in PPM group vs 0.6 in no-PPM group; P = 0.005). PPM occurred more in female gender, obese and older patients. PPM was highly associated with long-term all-cause mortality (median 4 years [Q1-Q3 2-7]; HR: 1.79, 95% CI: 1.27-2.55, P = 0.002), and remained strongly and independently associated after adjustment for other risk factors (HR: 1.60, 95% CI: 1.10-2.34, P = 0.014). In propensity score-matched analysis, the adjusted mortality risk was higher in PPM group (HR: 2.03, 95% CI: 1.22-3.39, P = 0.006) compared to no-PPM group. In a single-centre observational study, PPM increased early mortality and was independently associated with long-term all-cause mortality after low-risk, primary isolated AVR operations. Strategies to avoid PPM should be explored and implemented.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Female , Heart Valve Prosthesis Implantation/adverse effects , Humans , Prosthesis Design , Retrospective Studies , Treatment Outcome
7.
Innovations (Phila) ; 14(1): 27-36, 2019 Feb.
Article in English | MEDLINE | ID: mdl-30848711

ABSTRACT

OBJECTIVES: Aortic valve replacement (AVR) in patients with small aortic annulus (diameter ≤21 mm) is considered a challenging scenario because of technical aspects and the high risk of patient-prosthesis mismatch (PPM). The choice of the appropriate prosthesis is crucial, and at the moment, an ideal device has yet to be identified. We compare clinical and hemodynamic results after AVR with three bioprostheses with different design and characteristics. METHODS: We retrospectively evaluated 76 consecutive patients from two cardiac surgery centers who underwent AVR (Trifecta = 24; Edwards INTUITY Elite valve system = 26, and Perceval = 26) for severe aortic stenosis between 2013 and 2017. Patients selected were older than 75 years and with an annulus diameter ≤21 mm at preoperative echocardiogram. Reinterventions and combined procedures were excluded. Minimally invasive AVR was performed in 44 (57.8%) patients. Telephonic interview was obtained at 2.9 ± 0.5 years and echocardiographic follow-up at 2.2 ± 0.8 years. RESULTS: Clinical outcome was similar in the three groups. At follow-up, Trifecta patients presented significantly higher peak and mean transprosthetic pressure gradients ( P = 0.04 and 0.01). Effective orifice area and left ventricular mass regression were comparable, although an advantage was observed in Perceval patients without reaching the statistical significance. Incidence of moderate ( P = 0.2) and severe PPM ( P = 0.7) was comparable. CONCLUSIONS: Despite higher postoperative pressure gradients observed with the Trifecta valve, all three prostheses (Trifecta, Edwards INTUITY Elite, and Perceval) have proven to be reliable when implanted in small aortic annuli, with good clinical outcome and favorable left ventricular mass regression.


Subject(s)
Aortic Valve Stenosis/surgery , Aortic Valve/surgery , Heart Valve Prosthesis Implantation/methods , Heart Valve Prosthesis/trends , Aged , Aged, 80 and over , Aortic Valve/pathology , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/pathology , Echocardiography/methods , Female , Follow-Up Studies , Hemodynamics/physiology , Humans , Male , Prosthesis Design , Retrospective Studies , Treatment Outcome
8.
Int Heart J ; 59(3): 634-636, 2018 May 30.
Article in English | MEDLINE | ID: mdl-29743418

ABSTRACT

An 88-year-old woman was diagnosed with aortic stenosis and an aortic annulus that was too narrow to perform transcatheter aortic valve implantation. Surgery was performed through a 7-cm right mini-thoracotomy at the fourth intercostal space. A 19-mm aortic valve bioprosthesis was implanted after root enlargement. The fourth intercostal space was a suitable site for aortic root enlargement because of the shorter skin-to-root distance and the detailed exposure of the aortic valve after cutting the aortic wall. This study concluded that minimally-invasive aortic valve replacement following root enlargement can be an option for the treatment of elderly patients with aortic stenosis accompanied by an annulus that is too small to perform transcatheter aortic valve implantation.


Subject(s)
Aortic Valve Stenosis/surgery , Aortic Valve/surgery , Heart Valve Prosthesis Implantation/methods , Minimally Invasive Surgical Procedures/methods , Aged, 80 and over , Bioprosthesis/adverse effects , Female , Heart Valve Prosthesis/adverse effects , Humans , Tomography Scanners, X-Ray Computed
9.
Article in Japanese | WPRIM (Western Pacific) | ID: wpr-688743

ABSTRACT

When mitral valve dysfunction occurs in infants and mitral valve repair is difficult, mitral valve replacement (MVR) is required. However, commercially available prosthetic heart valves can be too large to implant in infants with a small annulus. In these children, the technique of supra-annular MVR is useful. Here we report two cases of supra-annular MVR, which were performed using an expanded polytetrafluoroethylene (ePTFE) graft as a skirt for a prosthetic valve. This method has been previously reported by Sung et al. The first case was a 16-month-old, 6.7-kg male infant who suffered from Shone' syndrome, mitral stenosis (MS) with a parachute mitral valve, coarctation of the aorta (CoA), and ventricular septal defect (VSD). MS progressed after CoA repair and VSD closure and a supra-annular MVR was performed. The second case was a 5-month-old, 4.9-kg female infant who suffered from polysplenia, intermediate atrioventricular septal defect (AVSD), and severe left atrioventricular valve regurgitation. AVSD repair was performed at the age of 3 months. However, valve stenosis and regurgitation gradually progressed postoperatively and consequently, a supra-annular MVR was performed. Postoperative prosthetic valve function was good in both cases. We believe that this method of performing supra-annular MVR is useful for infants with a small annulus.

10.
Int J Cardiol ; 240: 126-131, 2017 Aug 01.
Article in English | MEDLINE | ID: mdl-28606674

ABSTRACT

BACKGROUND: Transcatheter aortic valve implantation (TAVI) has been reported to be advantageous over surgical aortic valve replacement owing to the low incidence of prosthesis-patient mismatch (PPM) and large effective orifice area (EOA). However, data on TAVI for extremely small annuli are limited. The present study aimed to compare post-procedural hemodynamics and morphology between 20-mm and 23-mm Sapien XT (SXT) transcatheter heart valves (THVs) with extremely small annuli (<314mm2). METHODS: All patients with severe aortic stenosis treated with TAVI at eight Japanese centers between October 2013 and January 2016 were prospectively included in the Optimized CathEter vAlvular iNtervention (OCEAN-TAVI) registry. In the overall cohort of 20-mm (19 patients) and 23-mm SXTs (492 patients) with extremely small annuli, the patient groups were matched one-to-one using propensity scores, and post-procedural echocardiography and multidetector computed tomography data were compared for 18 matched patients from each group (matched cohort). RESULTS: In the matched cohort, the mean gradient was higher (15.4±4.1 vs. 12.2±4.8mmHg, p=0.04), EOA was lower (1.22±0.25 vs. 1.44±0.37cm2, p=0.02) and THV area was lower (245.6±19.1 vs. 298.5±33.3mm2, p<0.01) in the 20-mm group than in the 23-mm group. However, all patients in both groups were asymptomatic. Although moderate PPM was more prevalent in the 20-mm group than in the 23-mm group (31.6% vs. 7.9%, p<0.01), the incidence of severe PPM was low and similar between the groups (0% vs. 0.4%, p=1.00) in the overall cohort. CONCLUSION: A 20-mm SXT in patients who require a small bioprosthesis leads to favorable short-term outcomes.


Subject(s)
Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Registries , Transcatheter Aortic Valve Replacement/methods , Aged , Aged, 80 and over , Female , Follow-Up Studies , Humans , Male , Propensity Score , Prospective Studies