Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 639
Filter
1.
J Chromatogr A ; 1730: 465112, 2024 Jun 27.
Article in English | MEDLINE | ID: mdl-38972253

ABSTRACT

A macrocyclic peptide A was successfully purified in large quantities (∼30 g) in >95 % purity by an integrated two-step orthogonal purification process combining supercritical fluid chromatography (SFC) with medium-pressure reverse-phase liquid chromatography (MP-RPLC). MP-RPLC was used to fractionate the crude peptide A, remove unwanted trifluoroacetic acid (TFA) originating from the peptide A cleavage off the resin, and convert the peptide A into ammonium acetate salt form, prior to the final purification by SFC. A co-solvent of methanol/acetonitrile containing ammonium acetate and water in CO2 was developed on a Waters BEH 2-Ethylpyridine column. The developed SFC method was readily scaled up onto a 5 cm diameter column to process multi-gram quantities of the MP-RPLC fraction to reach > 95 % purity with a throughput/productivity of 0.96 g/h. The incorporation of SFC with MP-RPLC has been demonstrated to have a broader application in other large-scale polypeptide purifications.

2.
J Chromatogr A ; 1729: 465050, 2024 Aug 16.
Article in English | MEDLINE | ID: mdl-38852270

ABSTRACT

Herein, an improved subtraction model was proposed to characterise the polar stationary phases in supercritical fluid chromatography (SFC). Fifteen stationary phases were selected, including two types of aromatic columns, Waters Torus and Viridis series columns, as well as silica and amino columns. Ethylbenzene and Torus 1-AA were defined as the reference solute and column, respectively. Identifying the interaction with the maximum contribution to retention in SFC separation and using it as the initial term is a key step in modelling. The dipole, or induced dipole interaction (θ'P), replaced the hydrophobic interaction (η'H) as the starting term. The improved model was expressed as logα=η'H+ß'A+α'B+κ'C+θ'P+ε'E+σ'S, where the term ε'E indicated that anion exchange interaction was intentionally supplemented. A 7-step modelling process, including bidirectional fitting and residual analysis, was proposed. The obtained column parameters had reasonable physical significance, with the adjusted determination coefficient (R2adj) greater than 0.999 and the standard error (SE) less than 0.029. Methodological validation was further performed using the other four columns and 12 solutes that were not involved in the modelling. The result revealed good predictions of solutes' retention, as demonstrated by R2adj from 0.9923 to 0.9979 and SE from 0.0636 to 0.1088. This study indicated the feasibility of using the improved subtraction model to characterise polar stationary phases in SFC, with the most crucial being the determination of an initial term, followed by the addition of a new descriptor and the selection of an appropriate reference column. The study expanded the application scope of the subtraction model in SFC, which will help gain an in-depth understanding of the SFC separation mechanism.


Subject(s)
Chromatography, Supercritical Fluid , Hydrophobic and Hydrophilic Interactions , Chromatography, Supercritical Fluid/methods , Models, Chemical , Benzene Derivatives/chemistry , Silicon Dioxide/chemistry
3.
Se Pu ; 42(6): 581-589, 2024 Jun.
Article in Chinese | MEDLINE | ID: mdl-38845519

ABSTRACT

Oils and fats are commonly used in the pharmaceutical industry as solvents, emulsifiers, wetting agents, and dispersants, and are an important category of pharmaceutical excipients. Fatty acids with unique compositions are important components of oil pharmaceutical excipients. The Chinese Pharmacopoeia provides clear descriptions of the fatty acid types and limits suitable for individual oil pharmaceutical excipient. An unqualified fatty acid composition or content may indicate adulteration or deterioration. The fatty acid composition, as a key indicator for the identification and adulteration evaluation of oil pharmaceutical excipients, can directly affect the quality and safety of oil pharmaceutical excipients and preparations. Gas chromatography is the most widely used technique for fatty acid analysis, but it generally requires derivatization, which affects quantitative accuracy. Supercritical fluid chromatography (SFC), an environmentally friendly technique with excellent separation capability, offers an efficient method for detecting fatty acids without derivatization. Unlike other chromatographic methods, SFC does not use nonvolatile solvents (e. g., water) as the mobile phase, rendering it compatible with an evaporative light-scattering detector (ELSD) for enhanced detection sensitivity. However, the fatty acids in oil pharmaceutical excipients exist in the free and bound forms, and the low content of free fatty acids in these oil pharmaceutical excipients not only poses challenges for their detection but also complicates the determination of characteristic fatty acid compositions and contents. Moreover, the compositions and ratios of fatty acids are influenced by environmental factors, leading to interconversion between their two forms. In this context, saponification provides a simpler and faster alternative to derivatization. Saponification degrades oils and fats by utilizing the reaction between esters and an alkaline solution, ultimately releasing the corresponding fatty acids. Because this method is more cost effective than derivatization, it is a suitable pretreatment method for the detection of fatty acids in oil pharmaceutical excipients using the SFC-ELSD approach. In this study, we employed SFC-ELSD to simultaneously determine six fatty acids, namely, myristic acid, palmitic acid, stearic acid, arachidic acid, docosanoic acid, and lignoceric acid, in oil pharmaceutical excipients. Saponification of the oil pharmaceutical excipients using sodium hydroxide methanol solution effectively avoided the bias in the determination of fatty acid species and contents caused by the interconversion of fatty acids and esters. The separation of the six fatty acids was achieved within 12 min, with good linearity within their respective mass concentration ranges. The limits of detection and quantification were 5-10 mg/L and 10-25 mg/L, respectively, and the spiked recoveries were 80.93%-111.66%. The method proved to be sensitive, reproducible, and stable, adequately meeting requirements for the analysis of fatty acids in oil pharmaceutical excipients. Finally, the analytical method was successfully applied to the determination of six fatty acids in five types of oil pharmaceutical excipients, namely, corn oil, soybean oil, coconut oil, olive oil, and peanut oil. It can be combined with principal component analysis to accurately differentiate different types of oil pharmaceutical excipients, providing technical support for the rapid identification and quality control of oil pharmaceutical excipients. Thus, the proposed method may potentially be applied to the analysis of complex systems adulterated with oil pharmaceutical excipients.


Subject(s)
Chromatography, Supercritical Fluid , Excipients , Fatty Acids , Fatty Acids/analysis , Fatty Acids/chemistry , Chromatography, Supercritical Fluid/methods , Excipients/analysis , Excipients/chemistry , Scattering, Radiation , Light , Oils/chemistry , Oils/analysis
4.
Anal Bioanal Chem ; 2024 Jun 22.
Article in English | MEDLINE | ID: mdl-38907770

ABSTRACT

This work introduces a novel microfluidic backpressure pressure control developed for chip-based supercritical fluid chromatography (chipSFC). The presented on-chip pressure control mechanism involves the post-column addition of a viscous make-up stream, which enables pressure regulation within the range of 73 to 130 bar range. In contrast to approaches using mechanical backpressure regulators, this chip-based make-up-assisted pressure regulation offers a wear-free alternative that functions entirely through fluidic means and contributes minimally to extra column volume. It prevents phase separation of the supercritical mobile phase and, therefore, expands the analytical scope of chipSFC to detection systems with an ambient pressure interface. This was demonstrated by a proof-of-principle experiment, where a model mixture was separated within 30 s and detected using atmospheric pressure ionisation mass spectrometry.

5.
Talanta ; 276: 126295, 2024 Aug 15.
Article in English | MEDLINE | ID: mdl-38795649

ABSTRACT

Synthetic complex esters and polyol esters are incorporated as partially bio-based and biodegradable alternatives to petroleum base oils in lubricant formulations, to provide specific properties or performance and to help reducing their carbon footprint in certain cases. A sample can contain over 400 molecules of high chemical similarity including numerous isomers. To resolve such complexity, a separation technique with large peak capacity coupled to high-resolution mass spectrometry (HRMS) is essential. In this study, comprehensive off-line LCxSFC hyphenated with an Orbitrap analyzer was used for the structural elucidation of a synthetic bio-lubricant composed of a polyol reacted with fatty acids of varying length or with repetitive units of polyesters of ricinoleic acid. Retention in the LC first dimension was mostly due to the degree of oligomerization of ricinoleic acid within the polyester and to the chain length of the fatty acid. The SFC second dimension highlighted the esterification degree of the polyalcohol and the number and positions of fatty acids double bonds. The combination of both dimensions permitted the separation of isomers. The coupling of SFC with Orbitrap analyzer allowed an accurate assignment of molecular formulas. Finally, the fragmentation in the ionization source confirmed the attributed structures. By introducing a clear distribution of the chemical structures in the retention space, LCxSFC-HRMS provided a powerful analytical method for the comprehensive molecular characterization of the complex polyester polyols sample.

6.
Molecules ; 29(9)2024 May 03.
Article in English | MEDLINE | ID: mdl-38731614

ABSTRACT

In this study, water was used as an additive in the methanol-modified carbon dioxide-based eluent for the elution of some basic organic compounds from a hybrid silica column via supercritical fluid chromatography (SFC). The experiments were applied to sulfonamides, propranolol, and other organic nitrogen compounds involving aromatic rings from different classes of amine, pyrimidine, and purine with different pKa values (the pKa values for the studied analytes range from 4.6 to 10.4). The results revealed different responses to the different percentages of water addition. Adding 1~2% of water to the modifier (methanol) led to a positive effect manifested by more symmetrical peak shapes and reduced retention times for most compounds. The key factor for this improvement in the properties of chromatographic peaks is due to the adsorption of water on the silanol groups of the stationary phase, consequently resembling the phenomena observed in hydrophilic interaction liquid chromatography (HILIC). Moreover, the availability of hydrogen bond acceptor and donor sites in the analyte structure is an important factor to be considered when adding water as an additive to the modifier for improving the chromatographic peaks. However, introducing water in an amount higher than 3% resulted in perturbed chromatographic signals. It was also found that water as an additive alone could not successfully elute propranolol from the hybrid silica column with an acceptable peak shape; thus, the addition of a strong base such as amine salts was also necessary. The proposed use of a particular amount of water in the mobile phase could have a positive effect compared to the same mobile phase without water, improving the chromatographic peak properties of the elution of some basic organic compounds from the hybrid silica column.

7.
Article in English | MEDLINE | ID: mdl-38640794

ABSTRACT

Chromatography is a robust and reliable separation method that can use various stationary phases to separate complex mixtures commonly seen in metabolomics. This review examines the types of chromatography and stationary phases that have been used in targeted or untargeted metabolomics with methods such as mass spectrometry (MS) and nuclear magnetic resonance (NMR) spectroscopy. General considerations for sample pretreatment and separations in metabolomics are considered, along with the various supports and separation formats for chromatography that have been used in such work. The types of liquid chromatography (LC) that have been most extensively used in metabolomics will be examined, such as reversed-phase liquid chromatography and hydrophilic liquid interaction chromatography. In addition, other forms of LC that have been used in more limited applications for metabolomics (e.g., ion-exchange, size-exclusion, and affinity methods) will be discussed to illustrate how these techniques may be utilized for new and future research in this field. Multidimensional LC methods are also discussed, as well as the use of gas chromatography and supercritical fluid chromatography in metabolomics. In addition, the roles of chromatography in NMR- vs. MS-based metabolomics are considered. Applications are given within the field of metabolomics for each type of chromatography, along with potential advantages or limitations of these separation methods.


Subject(s)
Chromatography , Metabolomics , Animals , Humans , Chromatography, Liquid/methods , Hydrophobic and Hydrophilic Interactions , Magnetic Resonance Spectroscopy/methods , Mass Spectrometry/methods , Metabolomics/methods , Chromatography/methods
8.
Drug Test Anal ; 2024 Apr 10.
Article in English | MEDLINE | ID: mdl-38600723

ABSTRACT

Methadone has two enantiomers, which exhibit differences in pharmacological effects, with R-methadone being the active and S-methadone the inactive enantiomer. A robust, simple and rapid method for chiral separation of the two enantiomers in serum samples using ultra-high performance supercritical fluid chromatography-tandem mass spectrometry (UHPSFC-MSMS) has been developed and validated. Enantiomeric separation was achieved using a Chiralpak IH-3 column with a mobile phase consisting of CO2 and 30mM ammonium acetate in methanol/water (98/2, v/v). Runtime was 4 minutes. Sample preparation was semi-automated using a Hamilton ML Star robot with protein precipitation, and phospholipid removal was carried out using a Waters OSTRO™ 96-well plate. The calibration range was 50.0-1,500 nM for each enantiomer. The between-assay relative standard deviations were in the range of 1.2-3.6%. Matrix effects ranged from 99% to 115% corrected with internal standard. The method has been implemented in our laboratory and has proven to be a robust and reliable method for determining the ratio of R/S-methadone in authentic patient samples.

9.
Article in English | MEDLINE | ID: mdl-38635091

ABSTRACT

Persistent and mobile (PM) chemicals spread in the water cycle and have been widely detected, yet information about their sources is still scarce. In this study, 67 PM chemicals were analyzed in 19 wastewater samples taken in the sewer system of the city of Leipzig, Germany, covering different industrial, clinical, and domestic discharges. A total of 37 of these analytes could be detected, with highly variable median concentrations between substances (median: 0.5-800 µg L-1) and for single substances between samples (e.g., 1,4-diazabicyclo[2.2.2]octane) by up to three orders of magnitude, with the highest single concentration exceeding 10 mg L-1 (p-cumenesulfonic acid). The emission of PM chemicals into the sewer system was classified as stemming from diffuse (14 analytes) or point sources (23 analytes), while 9 analytes fulfill both criteria. Many so-called industrial chemicals were also discharged from households (e.g., tris(2-chloroethyl) phosphate or 1H-benzotriazole). Examples for analytes showing specific sources are tetrafluoroborate (traffic-related industry and metal production and finishing), ε-caprolactam (large-scale laundry), or cyanuric acid (likely swimming pool). Furthermore, a correlation between 1-cyanoguanidine and guanylurea was observed for the traffic-related industry. This study outlines that sewer sampling can provide valuable information on the sources of PM chemicals. This knowledge is a prerequisite for their future emission control at source or substitution as an alternative to end-of-pipe treatment in municipal wastewater treatment plants.

10.
Article in English | MEDLINE | ID: mdl-38513431

ABSTRACT

Fat-soluble vitamin D is an essential bioactive compound important for human health. Insufficient vitamin D levels can result not only in bone disease but also in other disorders, such as cancer, metabolic disorders, and diseases related to poor immune function. The current methods commonly used for vitamin D analysis are often applied to determine the levels of the most abundant metabolite in plasma, i.e., 25-OH-D2/D3. These methods do not consider the presence of other hydroxylated and esterified metabolites, including isomers and epimers, which are typically found in low concentrations. In this study, we developed a fast and selective ultra-high performance supercritical fluid chromatography (UHPSFC) method using a 150 mm long 1-amino anthracene (1-AA) column and a mobile phase consisting of carbon dioxide and methanol/isopropanol (1/1, v/v) mixed with 8 % water. After thorough optimization of column temperature and back pressure, the separation of four vitamin D3 esters, vitamin D3 and D2, and eight mono- and di-hydroxylated metabolites, including three groups of isomers, was achieved in 10 min. Two ion sources, atmospheric pressure chemical ionization (APCI) and atmospheric pressure photoionization optimized within this study, were compared in tandem mass spectrometry (MS/MS) detection. No significant sensitivity differences were observed. Subsequently, the same 1-AA column chemistry was examined in ultra-high performance liquid chromatography (UHPLC) as the stationary phase that could hypothetically bring different selectivity in the separation of vitamin D and its metabolites. However, this hypothesis was rejected, and C18 was used as a stationary phase in the final optimized UHPLC-MS/MS method. Despite detailed optimization, the final 15 min UHPLC method was not able to separate di-hydroxylated isomers of vitamin D3, while it enabled better resolution of esterified forms compared to UHPSFC. Optimized methods provided similar repeatability of retention times and peak areas, with RSD < 2 % and 10 %, respectively. The lowest limits of quantification were in the range of 1.2 - 4.9 ng/mL for UHPSFC-APCI-MS/MS, while for UHPLC-APCI-MS/MS, they were typically in the range of 2.6 - 9.6 ng/mL. Based on the obtained results, the UHPSFC-APCI-MS/MS method was the most promising approach for fast, selective, and sensitive analysis that could be applied in the analysis of biological samples with emphasis on the separation of both hydroxylated and esterified metabolites, including isomeric forms.


Subject(s)
Chromatography, Supercritical Fluid , Vitamin D , Humans , Tandem Mass Spectrometry/methods , Chromatography, High Pressure Liquid/methods , Chromatography, Supercritical Fluid/methods , Vitamins , Cholecalciferol
11.
J Chromatogr A ; 1720: 464811, 2024 Apr 12.
Article in English | MEDLINE | ID: mdl-38490143

ABSTRACT

A novel silica stationary phase was designed and prepared through thiol-epoxy click chemistry for supercritical fluid chromatography (SFC). The developed stationary phase was characterized by elemental analysis, Fourier transform infrared spectrometry and solid-state 13C/CP MAS NMR spectroscopy. In order to evaluate the chromatographic performance and retention mechanisms of the prepared column, a variety of alkaloids were used, including indoles, isoquinolines, pyrrolidines, piperidines, quinolizidines and organic amines. The stationary phase showed more symmetrical peak shapes and better performance for these compounds compared to the conventional SFC stationary phases. The investigations on the effects of pressure and temperature on retention provided information that the selectivity of the compounds can be improved by changing the density of the supercritical fluids. Moreover, it shows improved separation efficiency of three natural products with alkaloids as the main components at high sample loading. In conclusion, the developed stationary phase could offer flexible selectivity toward alkaloids and complex samples.


Subject(s)
Alkaloids , Chromatography, Supercritical Fluid , Chromatography, Supercritical Fluid/methods , Sulfhydryl Compounds , Temperature , Amines , Silicon Dioxide/chemistry
12.
Article in English | MEDLINE | ID: mdl-38520897

ABSTRACT

Extraction of vitamin D, including its hydroxylated and esterified metabolites, from soft tissues such as the liver is challenging due to the lipophilic character of matrix and analytes that are expected in very low concentration levels. In this study, we aimed at the optimization of two-step extraction using solid-liquid extraction as the first step, followed by solid-phase extraction. Various solvents, including ethanol, acetonitrile, methanol, acetone, heptane, and heptane with isopropanol, were investigated to isolate vitamin D compounds from liver tissue in the first step. Acetone was finally selected as the most suitable solvent for the solid-liquid extraction, with the highest recovery in the range of 67 - 98% for polar hydroxylated forms and 3 - 28% for lipophilic vitamin D and esters. Two solid phase extraction (SPE) based on the (i) "bind and elute strategy" and (ii) "removal strategy" using hydrophilic-lipophilic balanced SPE sorbent were optimized as a proceeding step for acetone extracts to increase the method selectivity. Finally, two optimized methods, combining solid-liquid extraction and individual SPE strategy, were examined in terms of sensitivity, recovery, matrix effect, accuracy, and precision. The limits of quantification were in the range of 1 - 10 ng/mL and 3 - 20 ng/mL analyzed by ultra-high performance supercritical fluid chromatography and ultra-high performance liquid chromatography hyphenated a with tandem mass spectrometer, respectively. The absolute recovery determined for the "bind and elute strategy" protocol was in the range of 3 - 24 %. Nevertheless, this method was free of matrix effects, which were determined to be in the 73 - 120 % range. On the contrary, the "removal strategy" approach provided higher recovery values for all compounds (47 - 123 %), but the results for nonpolar vitamin D and esters were strongly affected by signal suppression (matrix effects 3 - 51 %). Both methods fulfilled the criteria for accuracy and precision requested by the European Medicine Agency Guideline on Bioanalysis. "Removal strategy" SPE with decreased manual intervention and lower solvent consumption was finally applied to mouse liver tissue to determine vitamin D and its hydroxylated and esterified metabolites for the first time. The results, i.e., vitamin D esters detected in liver tissue, supported the notion that esters of vitamin D can be stored in lipophilic tissues to release vitamin D.


Subject(s)
Tandem Mass Spectrometry , Vitamin D , Animals , Mice , Tandem Mass Spectrometry/methods , Acetone , Chromatography, High Pressure Liquid/methods , Solvents , Vitamins , Liver , Heptanes , Solid Phase Extraction/methods
13.
Anal Bioanal Chem ; 416(6): 1485-1492, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38270634

ABSTRACT

The study focuses on the application range of nitrous oxide as a hold-up time marker in supercritical fluid chromatography (SFC). This compound has been suggested a decade ago to be used as unretained marker, something that the field of SFC was missing for a long time, since its beneficial properties make it an ideal candidate as hold-up time marker. Determination of the hold-up volume and actual volumetric flow rates have always been problematic in SFC due to the compressibility of carbon dioxide and one part of this is the difficulty of hold-up time measurements. Depending on the mobile phase, different methods have been used to measure the hold-up time with varying results. Nitrous oxide and other molecules have been compared in different conditions, mobile phases and stationary phases. In all cases, nitrous oxide gave the lowest elution times. However, detection was difficult in mobile phases containing 10% or more of organic modifier, because most solvents mask the signal of nitrous oxide. Interestingly, the choice of stationary phase also had a slight effect on detection, while different pressure and temperature settings affected each compound in a different manner.

14.
J Chromatogr A ; 1716: 464640, 2024 Feb 08.
Article in English | MEDLINE | ID: mdl-38219626

ABSTRACT

In the last decade, the separation application based on aromatic stationary phases has been demonstrated in supercritical fluid chromatography (SFC). In this paper, four aromatic stationary phases involving aniline (S-aniline), 1-aminonaphthalene (S-1-ami-naph), 1-aminoanthracene (S-1-ami-anth) and 1-aminopyrene (S-1-ami-py) were synthesized based on full porous particles (FPP) silica, which were not end-capped for providing extra electrostatic interaction. Retention mechanism of these phases in SFC was investigated using a linear solvation energy relationship (LSER) model. The aromatic stationary phases with five positive parameters (a, b, s, e and d+) can provide hydrogen bonding, π-π, dipole-dipole and cation exchange interactions, which belong to the moderate polar phases. The LSER results obtained using routine test solutes demonstrated that the aforementioned interactions of four aromatic stationary phases were influenced by the type and bonding density of the ligand, but to a certain extent. Furthermore, the LSER data verified that the S-1-ami-anth column based on full porous particles silica had higher cation exchange capacity (d+ value), compared to the commercialized 1-AA column (based on the ethylene-bridged hybrid particles). The relationship between the d+ value and SFC additive was quantitatively proved so as to regulate electrostatic interaction reasonably. This value was greatly increased by phosphoric acid, slightly increased by trifluoroacetic acid and formic acid, but significantly reduced by ammonium formate and diethylamine. Taking the S-1-ami-naph column as an example, better peek shape of the flavonoids was obtained after the addition of 0.1 % phosphoric acid in MeOH while isoquinoline alkaloids were eluted successfully within 11 min after adding 0.1 % diethylamine in MeOH. Combined with the unique π-π interaction and controllable electrostatic interaction, the aromatic stationary phases in this study have been proven to have expandable application potential in SFC separation.


Subject(s)
Chromatography, Supercritical Fluid , Phosphoric Acids , Chromatography, Supercritical Fluid/methods , Silicon Dioxide/chemistry , Cations , Aniline Compounds , Diethylamines
15.
Mass Spectrom (Tokyo) ; 13(1): A0141, 2024.
Article in English | MEDLINE | ID: mdl-38274031

ABSTRACT

A novel ionization technique named medium vacuum chemical ionization (MVCI) mass spectrometry (MS), which is a chemical ionization using oxonium (H3O+) and hydroxide (OH-) formed from water, has excellent compatibility with the supercritical fluid extraction (SFE)/supercritical fluid chromatography (SFC). We have studied a method to determine free fatty acids (FFAs) in a small section of bovine liver tissue using SFE/SFC-MVCI MS analysis without further sample preparation. A series of FFA molecules interact with the C18 stationary phase, exhibiting broad chromatographic peaks when using a non-modified CO2 as the mobile phase. It can be optimized by adding a small content of methanol to the mobile phase as a modifier; however, it may dampen the ionization efficiency of MVCI since the proton affinity of methanol is slightly higher than water. We have carefully evaluated the modifier content on the ion detection and column efficiencies. The obtained result showed that an optimized performance was in the range of 1 to 2% methanol-modified CO2 mobile phase for both column efficiency and peak intensity. Higher methanol content than 2% degrades both peak intensity and column efficiency. Using optimized SFC conditions, a section of bovine liver tissue sliced for 14 µm thickness by 1 mm square, which is roughly estimated as about 3300 hepatocytes, was applied to determine 18 FFAs amounts for carbon chains of C12-C24. An amount of each tested FFA was estimated as in the range of 0.07 to 2.6 fmol per cell.

16.
J Sep Sci ; 47(1): e2300550, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38066382

ABSTRACT

Valeriana jatamansi Jones is a commonly used traditional Chinese medicine, boasting rich effective compositions with versatile chemical structures and wide polarity, including iridoids, chlorogenic acid, and flavonoids. Previous reports indicate that conventional high-performance liquid chromatography (HPLC) analytical methods have proven inefficient performance in comprehensively characterizing components in Valeriana jatamansi. In the present study, a hybrid online analytical platform combining supercritical fluid extraction with both conventional HPLC separation (reverse phase) and supercritical fluid chromatography (normal phase) has been established and validated. This system can provide online extraction with two different chromatographic separation modes to increase separation ability and has been connected to a mass spectrometer to acquire high-resolution mass spectrometry data. Then, the online platform was applied to screening components in Valeriana jatamansi. A total of 117 compounds were identified, including five lignans, 18 organic acids, six flavonoids, and 88 iridoids. Thirty-three compounds were reported from Valeriana jatamansi for the first time. These results enrich our understanding of the components of Valeriana jatamansi and prove that the developed online platform in this study is a robust approach for accelerating working efficiency in comprehensively analyzing complicated samples.


Subject(s)
Chromatography, Supercritical Fluid , Valerian , Valerian/chemistry , Chromatography, High Pressure Liquid , Mass Spectrometry , Iridoids/analysis , Flavonoids/analysis
17.
J Sep Sci ; 47(1): e2300623, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38066396

ABSTRACT

A supercritical fluid chromatography-tandem mass spectrometry (SFC-MS/MS) technique was developed for the rapid and simultaneous detection of nine pesticides (carbendazim, isoprocarb, paclobutrazol, isoprothiolane, flusilazole, quinalphos, piperonylbutoxide, propargite, and bioresmethrin) in rice, wheat, and maize. The cereal samples were extracted with a solution of 0.5% acetic acid in acetonitrile and purified using quick, easy, cheap, effective, rugged, and safe method. The samples were characterized using multi-reaction monitoring and quantified with the external standard method. Excellent linearities (R2  > 0.9991) and limits of quantification (0.4-40.0 µg/kg) were established for all nine pesticides. Satisfactory pesticide recovery rates (62.2%-107.4%) were obtained at three standard concentrations (50, 100, and 200 µg/kg), with relative standard deviations in the range of 2.1%-14.3%. The results confirmed that the proposed method was suitable for the routine detection of these pesticides in grain samples. Compared with high-performance liquid chromatography-MS/MS, the overall test run time and the amount of solvent required were reduced by 66% and 90%, respectively, when SFC-MS/MS was applied. Therefore, the use of SFC-MS/MS permits a shorter run time and affords greater analytical efficiency, such that it is both economical and environmentally sustainable.


Subject(s)
Chromatography, Supercritical Fluid , Pesticide Residues , Pesticides , Tandem Mass Spectrometry/methods , Pesticide Residues/analysis , Edible Grain/chemistry , Chromatography, Supercritical Fluid/methods , Pesticides/analysis , Chromatography, High Pressure Liquid/methods
18.
Chirality ; 36(1): e23621, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37737018

ABSTRACT

In this study, crown ether-derived column Crownpak® CR-I (+) was evaluated under SFC conditions using 12 primary amines, and the chromatographic results were compared against eight immobilized polysaccharide-based columns. Crownpak® CR-I (+) achieved a significantly higher success rate. It was found that the addition of 5% water to the modifier dramatically improved the peak shape for chiral separation of primary amines on Crownpak® CR-I (+). The first reported preparative SFC separations on Crownpak® CR-I (+) are shown, offering a new approach for the preparative resolution of primary amines. The case studies demonstrate that Crownpak® CR-I (+) is a very useful column in the chiral separation of challenging compounds that contain a primary amine group in the pharmaceutical industry.

19.
Chirality ; 36(1): e23626, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37920131

ABSTRACT

In this study, the performance of the widely used "golden four" coated chiral stationary phases (Chiralpak AD-3, Chiralcel OD-3, Chiralpak AS-3, and Chiralcel OJ-3) was compared with their corresponding immobilized versions (Chiralpak IA-3, Chiralpak IB-3, Chiralpak IB N-3, Chiralpak IH-3, and Chiralpak IJ-3) under supercritical fluid chromatography (SFC) conditions with a set of 30 racemic compounds. Using the traditional modifiers, methanol and isopropanol, the immobilized columns (Chiralpak IB N-3 and Chiralpak IH-3) showed an improved general ability to successfully resolve the enantiomers of the target analytes relative to their coated versions (Chiralcel OD-3 and Chiralpak AS-3), while the coated columns (Chiralpak AD-3, Chiralcel OD-3, and Chiralcel OJ-3) performed better than their immobilized versions (Chiralpak IA-3, Chiralpak IB-3, and Chiralpak IJ-3). An investigation of the non-traditional modifiers, dichloromethane, ethyl acetate, and tetrahydrofuran with immobilized columns, revealed a generally decreased ability to successfully resolve the enantiomers of the target analytes, relative to the use of the traditional modifiers, methanol and isopropanol. The stability of the coated columns (Chiralpak AD-H and Chiralcel OD-H) was evaluated by injecting "forbidden" solvents, including dichloromethane, dimethyl sulfoxide, and tetrahydrofuran. After 200 injections of these solvents on coated columns, the retention factors and resolutions slightly decreased, and a significant increase in column backpressure was observed, indicating some degree of stationary phase degradation.

20.
Electrophoresis ; 45(3-4): 218-233, 2024 Feb.
Article in English | MEDLINE | ID: mdl-37794622

ABSTRACT

In this work, a preparative supercritical fluid chromatography (SFC) method was first developed to separate a series of chiral compounds evaluated as lactam-based P2RX7 antagonists. Subsequently, high-performance liquid chromatography, SFC, and capillary electrophoresis (CE) were comparatively investigated as QC tools to determine the enantiomeric purity of the separated isomers, including analytical performance and greenness. The screening of the best conditions was carried out in liquid and SFC on the nine derivatives and the amylose tris(3,5-dimethylphenylcarbamate)-based chiral stationary phase was found to be highly efficient. The same screening was carried out in CE and very different conditions, either in acidic or basic background electrolyte and different cyclodextrins used as chiral selectors, allowed the separation of six of the nine derivatives. 1-((3,4-Dichlorophenyl)carbamoyl)-5-oxopyrrolidine-2-carboxylic acid (compound 1) was chosen as a probe, and its semi-preparative separation by SFC and enantiomeric verification using the three techniques are presented. Its limit of detection and limit of quantification are calculated for each method. Finally, the greenness of each quality control method was evaluated.


Subject(s)
Amylose , Chromatography, Supercritical Fluid , Chromatography, High Pressure Liquid/methods , Chromatography, Supercritical Fluid/methods , Stereoisomerism , Electrophoresis, Capillary
SELECTION OF CITATIONS
SEARCH DETAIL
...