Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 733
Filter
1.
Odontology ; 2024 Jul 04.
Article in English | MEDLINE | ID: mdl-38963521

ABSTRACT

To evaluate the physical properties of enamel submitted to hydrogen peroxide (HP) incorporated with titanium dioxide nanoparticles (NP) co-doped with nitrogen and fluorine and irradiated with violet LED light (LT). Enamel-dentin disks were randomly allocated (T0) into groups, according to HP (HP6, HP15, or HP35) and NP (no NP, 5NP, or 10NP) concentrations, and irradiated or not with LT. A negative control (NC) group was set. After three bleaching sessions (T1, T2, and T3), specimens were stored in saliva for 14 days (T4). Enamel surface microhardness number (KHN), surface roughness (Ra), cross-sectional microhardness (ΔS), energy-dispersive spectroscopy (EDS), scanning electron (SEM), and polarized light (PLM) microscopies were performed. Surface KHN was significantly influenced by NP over time, independently of LT irradiation. At T3 and T4, gels with 5NP and 10NP exhibited no KHN differences compared to NC and baseline values, which were not observed under the absence of NP. NP incorporation did not statistically interfere with the ΔS and Ra. PLM images exhibited surface/subsurface darkening areas suggestive of demineralizing regions. SEM demonstrated some intraprismatic affection in the groups without NP. EDS reported a higher enamel calcium to phosphorus ratio following 10NP gels applications. Gels with NP maintained the enamel surface microhardness levels and seemed to control surface morphology, upholding the mineral content. None of the proposed experimental protocols have negatively influenced the enamel surface roughness and the cross-sectional microhardness.

2.
J Photochem Photobiol B ; 257: 112970, 2024 Jun 28.
Article in English | MEDLINE | ID: mdl-38955079

ABSTRACT

The aim of this study was to evaluate the effectiveness of a laser-assisted in-office tooth bleaching treatment, employing a diode laser (445 nm) using different power and time settings. Two hundred human incisors were collected for evaluating tooth color change (ΔΕ00) and whiteness index in dentistry (ΔWID) following laser-assisted tooth bleaching treatment. The specimens were distributed into 25 groups (n = 8) according to laser output power (0.5-2 W) and duration of irradiation (10-60 s) that was applied. ΔΕ00 and ΔWID were evaluated using a spectrophotometer at three points of time (24 h, 1 week and 1 month after treatments). Three-way ANOVA revealed that power, duration of laser irradiation, and time of measurement after bleaching treatments significantly affected both ΔΕ00 and ΔWID(p < 0.05). Furthermore, laser irradiation increased ΔΕ00 and ΔWID at all applied powers compared to the control group (p < 0.05), but this increase was dependent on the duration of irradiation. Laser irradiation significantly increased ΔΕ00 when the duration of operation was 50-60 s at 0.5-1 W, while at 1.5-2 W was significantly increased when the duration was 30-60 s. ΔWID was significant higher in the laser groups compared to the control group at all powers, except for 0.5 W where it was significant higher when the duration was 50-60 s. The outcomes of the study can help in selecting the suitable power settings and duration of laser exposure to achieve the optimal whitening results while ensuring the safety of the tooth pulp.

3.
Front Dent ; 21: 14, 2024.
Article in English | MEDLINE | ID: mdl-38919769

ABSTRACT

Objectives: Teeth bleaching is an accepted and modern treatment in cosmetic dentistry. Bleaching agents may affect amalgam restorations and increase mercury release; therefore, patients are at increased risk of mercury exposure in the body. The aim of this study was to investigate the effect of polishing and universal bonding application on mercury release from aged amalgams exposed to bleaching. Materials and Methods: In this in-vitro experimental study, 64 dental amalgam specimens with dimensions of 3×5×10 were prepared and divided into two experimental and control groups. Each group was further divided into 4 subgroups and received one of the following treatments: no intervention, surface bonding, polishing, or polishing and surface bonding. Subsequently, the samples were immersed in bleaching agent containing 7% hydrogen peroxide and the amount of mercury released after 96h was measured. The results were analyzed by two-way ANOVA and Tukey post hoc tests (α≤0.05). Results: The results showed that the type of solution (P<0.05) and surface treatment (P<0.001) significantly affected the level of mercury release. However, there was no significant interaction between surface treatment methods in the bleaching group and those in the phosphate buffer group (P=0.621). Conclusion: Bleaching agents were found to enhance mercury release from dental amalgam. The application of polishing and universal bonding on amalgam surfaces exhibited significant effects on the reduction of the mercury release.

4.
Bioengineering (Basel) ; 11(6)2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38927795

ABSTRACT

INTRODUCTION: In recent years, tooth whitening has become one of the most popular ways of achieving the original tooth color. The effect of whitening gel can be improved through heat, light or laser. The bond strength between the enamel and the composite can be reduced through bleaching and laser radiation. The purpose of this study is to assess the shear bond strength of resin composite to enamel after a bleaching process using hydrogen peroxide, with and without a laser (970 nm and 445 nm lasers). METHOD: This study used 51 extracted anterior teeth without caries that were divided into three groups. A 40% hydrogen peroxide gel was used on the enamel of all teeth. The control group received bleaching without a laser. Both the second and third treatment groups received bleaching with a laser, one with 970 nm and the other with 445 nm. After the bleaching process, all groups had etching, bonding and curing of the composite performed. Lastly, the shear bond strength between the enamel and the composite was measured and the failure modes were recorded. The data were compared using a one-way ANOVA test. RESULTS: The mean shear bond strength between the enamel and the composite in the 445 nm group three (445 nanometer) was significantly lower than the other groups (p < 0.05). There was no significant difference between the control and the 970 nm groups (p = 0.2). CONCLUSION: According to the laser wavelengths and parameters that were used in this study and the results of this study, office bleaching with a 445 nm laser weakened the shear bond strength between the enamel and the composite.

5.
J Esthet Restor Dent ; 2024 Jun 09.
Article in English | MEDLINE | ID: mdl-38853343

ABSTRACT

AIM: This study evaluated the efficacy and cytotoxicity of 35% hydrogen peroxide (HP) gel incorporated with 10% (w/w) biosilicate (BioS) on sound enamel and early-stage enamel erosion lesions. METHODS: Discs of enamel/dentin were selected, subjected to erosive cycles (0.3% citric acid, pH 2.6), and treated with (n = 8): HP (35% HP, positive control); HP_BioS [carboxymethyl cellulose (CMC) + HP + BioS]; BioS (CMC + BioS); CMC (negative control). The discs were adapted to artificial pulp chambers with the enamel exposed for bleaching, and the dentin facing toward the culture medium (Dulbecco's modified Eagle's medium [DMEM]). Bleaching was performed in three 30-min sessions at 7-day intervals. After bleaching, the diffusion product (DMEM extract + diffused HP) was pipetted onto MDPC-23 odontoblastic cell line and inoculated. Color parameters (ΔL, Δa, Δb), color change (ΔE00), and changes in whiteness index (ΔWID) were determined before (T0) and after the last bleaching session (T3). Cell viability (MTT, %), H2O2 diffusion (µg/mL), oxidative cell stress (OxS), and cell fluorescence (live/dead assay, in confocal microscopy) were assessed (ANOVA/Tukey; α = 0.05). RESULTS: No difference in ΔL, Δa, Δb, ΔE00, and ΔWID were found between HP and HP_BioS (p > 0.05). The incorporation of BioS decreased the HP diffusion into the substrates and mitigated oxidative stress in early-stage eroded enamel (p < 0.05). HP_BioS presented significantly higher cell viability compared with HP under erosion conditions. Live/dead assay indicated that BioS_HP maintained viability with larger clusters of viable cells. CONCLUSION: Incorporating BioS into HP maintained bleaching effectiveness, favored cell viability, reduced the oxidative stress, and the cytotoxicity in teeth with early-stage erosion. CLINICAL SIGNIFICANCE: BioS formulation showed promising results for reducing cytotoxicity in patients seeking tooth bleaching and presenting undetectable early-stage erosion.

6.
Cureus ; 16(5): e59806, 2024 May.
Article in English | MEDLINE | ID: mdl-38846193

ABSTRACT

Fluorosis is a widespread condition that is endemic and found in approximately 25 nations worldwide. It manifests as dental fluorosis, an inherited enamel imperfection resulting from excessive fluoride exposure during tooth development. This condition can lead to varying degrees of tooth discoloration, often requiring aesthetic correction. Bleaching represents one of the treatment approaches for such instances, with in-office power bleaching being a technique that comprises the clinical implementation and triggering of bleaching agents using light to expedite the procedure. This case report outlines the successful aesthetic revision of moderate dental fluorosis through power bleaching, obviating the demand for intrusive procedures. It underscores the efficacy and conservative nature of in-office power bleaching to address tooth discoloration associated with extensive fluorosis.

7.
Restor Dent Endod ; 49(2): e14, 2024 May.
Article in English | MEDLINE | ID: mdl-38841380

ABSTRACT

This study aimed to answer the question through a systematic review: Can carbamide peroxide be as effective as hydrogen peroxide and cause less in-office bleaching sensitivity? A literature survey was performed in PubMed/MEDLINE, Embase, Scopus, ISI Web of Science, and gray literature. Primary clinical trials that compared the efficacy or the in-office bleaching sensitivity between carbamide and hydrogen peroxides were included. The risk of bias was evaluated using the RoB2. The certainty of the evidence was assessed using the GRADE approach. DPI training significantly improved the mean scores of the dental undergraduates from 7.53 in the pre-DPI-training test to 9.01 in the post-DPI-training test (p < 0.001). After 6 weeks, the mean scores decreased marginally to 8.87 in the retention test (p = 0.563). DPI training increased their confidence level from 5.68 pre-DPI training to 7.09 post-DPI training. The limited evidence suggests that the 37% carbamide peroxide may be similarly effective to the 35% hydrogen peroxide for bleaching teeth in-office and causes less bleaching sensitivity. However, more well-designed split-mouth clinical trials are necessary to strengthen the evidence.

8.
J Conserv Dent Endod ; 27(4): 378-382, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38779207

ABSTRACT

Background: The world of esthetic dentistry is constantly making efforts toward the management of tooth staining. Laser-assisted bleaching is needed before adhesive restorations and has become common and advantageous as it accelerates bleaching action, reduces postoperative sensitivity, and promotes recrystallization of enamel. Aim: The study aimed to evaluate and compare the bond strength of diode (Biolace: EpicX) and neodymium-doped:yttrium aluminum garnet (Nd:YAG) (LightWalker, Fotona, Slovenia) assisted bleached (Pola Office, SDI) enamel with nanofilled composite (GC Solare Sculpt). Materials and Methods: The samples were divided into three groups (n = 11): Group A - Conventionally bleached enamel, Group B - Diode laser-assisted bleached enamel, Group C - Nd:YAG laser-assisted bleached enamel. After storing samples in Artificial Saliva for 2 weeks, bonding was performed, and nanofilled composite resin was applied through an incremental method. Samples were subjected to shear bond strength (SBS) analysis. Conclusion: The use of Nd:YAG laser on bleached enamel significantly increases the bond strength with nanofilled composite resin.

9.
J Clin Med ; 13(8)2024 Apr 16.
Article in English | MEDLINE | ID: mdl-38673574

ABSTRACT

Background In the current cosmetics industry, bleaching is often associated with lasers. However, such treatment also harbors risks. Tooth death is observed at pulpal temperature increases ≥5.6 °C. Therefore, it seems important to investigate the effects of using different lasers. The aim of this study was to determine pulpal temperature increases at different laser parameters during bleaching by modeling a realistic environment and to compare the temperature recording using a thermocouple and thermal camera. The authors assumed that there are laser settings for the lasers used at which the pulpal temperature increases are <5.6 °C and that the temperature recordings with thermocouples and thermal cameras differ only minimally. Methods Human teeth were used, which were extracted for dental reasons. During experiment, teeth were bleached conventionally and by laser activation at 940 nm, 445 nm, and 970 nm. The temperature in the pulp was recorded using thermocouples. In a second setup, longitudinally halved teeth were bleached, while the temperature in the pulp was recorded with a thermocouple and thermal camera. Descriptive statistics were used. The significance level is 0.05. Results In addition to conventional bleaching, temperature increases <5.6 °C were observed for bleaching at 940 nm 1.5 W, at 445 nm 0.3 W, and at 970 nm 0.5 W. For bleaching procedures using 940 nm 7 W, 940 nm 2 W, 445 nm 0.5 W, and 970 nm 1 W, the temperature increase was ≥5.6 °C. Significant differences (p < 0.05) were found in the maximum temperature increases (°C) between all groups. Temperature recordings using a thermocouple and thermal camera differed by about 2.3 °C. The working hypotheses were confirmed. Conclusion With laser bleaching, attention must be paid to the type of laser, its power, and the time in order to avoid excessive overheating of the dental pulp.

10.
J Dent ; 145: 104989, 2024 06.
Article in English | MEDLINE | ID: mdl-38582435

ABSTRACT

OBJECTIVE: To map and summarize the current scientific evidence concerning the active ingredients, effectiveness, and adverse effects of over-the-counter (OTC) bleaching products. DATA AND SOURCE: This study was conducted according to the PRISMA-ScR guidelines for scoping reviews and registered on the Open Science Framework platform. STUDY SELECTION: Database searches were conducted in PubMed/MEDLINE, Embase, and Scopus up to January 2024. All in vitro, in situ, and clinical studies evaluating the effectiveness and adverse effects of OTC bleaching products were included. A descriptive analysis of the included studies was performed. RESULTS: A total of 88 studies were included. Most of them were in vitro studies (n = 49), followed by randomized clinical trials (n = 28). The main OTC bleaching products identified were whitening or stain-removing toothpastes (n = 42), followed by whitening strips (n = 39). Most clinical studies indicate that whitening strips are effective in improving tooth color and providing whitening benefits. In contrast, the bleaching effectiveness of toothpastes, mouth rinses and whitening trays was mainly supported by in vitro studies. The main adverse effects associated with OTC bleaching agents were tooth sensitivity and gingival irritation. CONCLUSION: A wide variety of OTC bleaching products is available for consumer self-administered use. Clinical studies have mainly confirmed the bleaching effectiveness of whitening strips, while the validation for toothpastes, mouth rinses and whitening trays has mainly relied on in vitro studies. Nevertheless, the use of OTC bleaching products may result in adverse effects, including tooth sensitivity, gingival irritation, and enamel surface changes. CLINICAL SIGNIFICANCE: Some over-the-counter bleaching products may have whitening properties supported by clinical studies, particularly those containing hydrogen or carbamide peroxide. Nonetheless, clinicians must be aware of the potential risks associated with excessive self-administration of these products, which may result in adverse effects.


Subject(s)
Tooth Bleaching Agents , Tooth Bleaching , Toothpastes , Humans , Carbamide Peroxide/therapeutic use , Dentin Sensitivity/chemically induced , Hydrogen Peroxide/therapeutic use , Hydrogen Peroxide/adverse effects , Mouthwashes/therapeutic use , Mouthwashes/adverse effects , Nonprescription Drugs/therapeutic use , Nonprescription Drugs/adverse effects , Tooth Bleaching/adverse effects , Tooth Bleaching/methods , Tooth Bleaching Agents/therapeutic use , Tooth Bleaching Agents/adverse effects , Tooth Discoloration/chemically induced , Tooth Discoloration/drug therapy , Toothpastes/therapeutic use , Toothpastes/adverse effects
11.
Photodiagnosis Photodyn Ther ; 47: 104101, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38663486

ABSTRACT

BACKGROUND: Using hydrogen peroxide (HP) for tooth bleaching may induce various side effects. Cold atmospheric plasma (CAP) is a promising solution. We aimed to evaluate and compare the efficacy and safety of tooth bleaching using high-concentration HP with CAP with conventional in-office bleaching. METHODS: Fifty-one discolored extracted human teeth were assigned to three groups: Group 1 (light-emitting diode with 35 % HP), Group 2 (CAP with 35 % HP), and Group 3 (only CAP). Bleaching was conducted over three sessions for a total of 20 min. The bleaching effect was evaluated based on the changes in color (ΔE00 and WID) and lightness (ΔL⁎ and ΔG). Safety was assessed by examining the dark areas on the enamel and monitoring the pulp chamber temperature. The study analyzed how different bleaching methods and durations affected ΔE00 and ΔWID using repeated-measures analysis of variance (ANOVA). The Kruskal-Wallis and Mann-Whitney tests were used for ΔL⁎ and dark areas, and one-way ANOVA for ΔG after 20 min of bleaching. RESULTS: The ΔE00 and WID demonstrated an interaction based on the bleaching method and time, with Group 1 exhibiting the highest ΔE00 and WID at all treatment times (p < 0.001). ΔL⁎ and ΔG did not differ significantly between Groups 1 and 2 (p = 0.056 and 0.062, respectively) and were lowest in Group 3 (p < 0.001). Group 1 exhibited the darkest areas and highest pulp chamber temperatures (p < 0.001). Group 1 exhibited statistically significant color changes. Group 2 demonstrated similar effects, but with enhanced safety profiles. CONCLUSIONS: Group 2, although displaying a slightly less pronounced color change compared with Group 1, achieved a color alteration readily discernible to the naked eye. This suggests that CAP with 35 % HP could be an interesting area for further investigation as an alternative to traditional in-office bleaching methods.


Subject(s)
Hydrogen Peroxide , Plasma Gases , Tooth Bleaching Agents , Tooth Bleaching , Humans , Tooth Bleaching/methods , Tooth Bleaching/adverse effects , Plasma Gases/pharmacology , Tooth Bleaching Agents/pharmacology , In Vitro Techniques , Tooth Discoloration/drug therapy
12.
Arch Oral Biol ; 161: 105937, 2024 May.
Article in English | MEDLINE | ID: mdl-38442471

ABSTRACT

OBJECTIVE: To evaluate the role of induced nitric oxide synthase (iNOS) in nociception/orofacial discomfort in rats submitted to tooth whitening with hydrogen peroxide (H2O2). DESIGN: Wistar rats were divided into three groups (n = 24/group): a sham group not submitted to whitening treatment, a saline group submitted to whitening treatment, and a test group submitted to whitening treatment and blockade of iNOS with aminoguanidine 50 mg/kg/day. After 24 and 48 h, and 7 days, the animals were euthanized to collect trigeminal ganglia and maxillae to histomorphometric analysis (size of neuronal bodies and percentage of pulp area filled by vessels) and behavior/nociception (Grimace scales, scratching and biting counting, weight loss and nociception assay). ANOVA-1- or - 2-way tests were used (p < 0.05, GraphPadPrism 5.0). RESULTS: The aminoguanidine-treated group showed a reduction in nociceptive threshold in the masseteric region (p < 0.001), Grimace scale scores (p < 0.001), number of scratching (p = 0.011) and body mass loss (p = 0.007). After 24 and 48 h of tooth bleaching, the saline group showed a significant increase in the mean area of the blood vessels (p = 0.020) and iNOS immunostaining in odontoblasts (p = 0.002) and non-odontoblasts cells (p = 0.025). Aminoguanidine reversed both increases. Tooth bleaching reduced the mean area of neuronal bodies, and aminoguanidine significantly reversed it (p = 0.019), but an increase in GFAP immunostaining in neuronal bodies did not reduce after seven-days or after aminoguanidine treatment (p = 0.003). CONCLUSION: iNOS blockage by aminoguanidine plays an important role in nociception and orofacial discomfort by control of inflammation in dental pulp after tooth bleaching with hydrogen peroxide (H2O2) 35%.


Subject(s)
Guanidines , Tooth Bleaching Agents , Tooth Bleaching , Rats , Animals , Hydrogen Peroxide/pharmacology , Nociception , Nitric Oxide , Rats, Wistar , Nitric Oxide Synthase
13.
Clin Oral Investig ; 28(3): 189, 2024 Mar 02.
Article in English | MEDLINE | ID: mdl-38430338

ABSTRACT

OBJECTIVES: To assess color change efficacy and the adverse effects of varied over-the-counter (OTC) bleaching protocols. METHODOLOGY: The study included randomized clinical trials evaluating color changes from OTC bleaching agents. Nine databases were searched, including the partial capture of the grey literature. The RoB2 tool analyzed the individual risk of bias in the studies. Frequentist network meta-analyses compared treatments through common comparators (∆Eab* and ∆SGU color changes, and tooth sensitivity), integrating direct and indirect estimates and using the mean and risk differences as effect measures with respective 95% confidence intervals. The GRADE approach assessed the certainty of the evidence. RESULTS: Overall, 37 remaining studies constituted the qualitative analysis, and ten composed the meta-analyses. The total sample included 1,932 individuals. ∆Eab* was significantly higher in groups 6% hydrogen peroxide (HP) strips (≥ 14 h). ∆SGU was significantly higher in groups at-home 10% carbamide peroxide (CP) (≥ 14 h), followed by 6% HP strips (≥ 14 h) and 3% HP strips (≥ 14 h). At-home 10% CP (7-13 h) and placebo showed lower risks of tooth sensitivity without significant differences between these treatments. CONCLUSION: Considering the low level of evidence, OTC products presented satisfactory short-term effects on tooth bleaching compared to the placebo, with little to no impact on dentin hypersensitivity and gingival irritation. CLINICAL RELEVANCE: OTC products are proving to be practical alternatives for tooth whitening. However, patients should be advised about the possible risks of carrying out such procedures without professional supervision.


Subject(s)
Dentin Sensitivity , Tooth Bleaching Agents , Tooth Bleaching , Humans , Carbamide Peroxide , Color , Dentin Sensitivity/drug therapy , Hydrogen Peroxide , Hypochlorous Acid , Network Meta-Analysis , Nonprescription Drugs/adverse effects , Peroxides , Tooth Bleaching/adverse effects , Tooth Bleaching/methods , Tooth Bleaching Agents/adverse effects , Tooth Bleaching Agents/pharmacology , Urea
14.
Clin Oral Investig ; 28(4): 224, 2024 Mar 21.
Article in English | MEDLINE | ID: mdl-38509406

ABSTRACT

OBJECTIVES: To evaluate the bleaching efficacy and permeability of hydrogen peroxide (HP) in the pulp chamber of human teeth bleached with lower concentrations of carbamide peroxide gel (4%, 5% and 7% CP). MATERIALS AND METHODS: Bleaching gels with lower concentrations were formulated and a commercial standard gel, 10% CP, was used as a reference. Fifty-six human premolars were randomly divided into four groups. Applications of the bleaching gel were made for 3 h for 21 days. The bleaching efficacy was evaluated by digital spectrophotometry on 1, 7, 14 and 21 days, with analysis in the ∆Eab, ∆E00 and WID color spaces. The concentration of HP in the pulp chamber was measured in the same periods by UV-Vis spectrophotometry (µg/mL). Two-way repeated analysis of variance (ANOVA) examined bleaching efficacy and HP permeability, followed by Tukey's post-hoc test (α = 0.05). RESULTS: All groups showed significant color changes, with no statistical differences after the second and third week of bleaching (p > 0.05). The 'time' factor was statistically different (p < 0.05), increasing the bleaching efficacy throughout the treatment. The 4% CP group had lower HP levels in the pulp chamber (p < 0.05). CONCLUSIONS: The results seem promising, revealing that low concentration gels are as effective as 10% CP with the benefit of reducing the amount of HP in the pulp chamber. CLINICAL RELEVANCE: Low concentration 4% PC and 5% PC maintains bleaching efficacy, reduces the penetration of HP peroxide into the pulp chamber, and may reduce tooth sensitivity.


Subject(s)
Tooth Bleaching Agents , Tooth Bleaching , Humans , Carbamide Peroxide , Dental Pulp Cavity , Tooth Bleaching Agents/pharmacology , Hydrogen Peroxide , Tooth Bleaching/methods , Hypochlorous Acid , Gels , Urea/pharmacology , Peroxides/pharmacology
15.
J Mech Behav Biomed Mater ; 153: 106497, 2024 May.
Article in English | MEDLINE | ID: mdl-38458078

ABSTRACT

OBJECTIVE: To evaluate whether coating enamel with a polymeric primer (PPol) containing titanium tetrafluoride (TiF4) before applying a bleaching gel with 35% H2O2 (35% BG) increases esthetic efficacy, prevents changes in morphology and hardness of enamel, as well as reduces the cytotoxicity from conventional in-office bleaching. MATERIALS AND METHODS: Standardized enamel/dentin discs were stained and bleached for 45 min (one session) with 35% BG. Groups 2TiF4, 6TiF4, and 10TiF4 received the gel on the enamel previously coated with PPol containing 2 mg/mL, 6 mg/mL, or 10 mg/mL, respectively. No treatment or application of 35% BG directly on enamel were used as negative control (NC), and positive control (PC), respectively. UV-reflectance spectrophotometry (CIE L*a*b* system, ΔE00, and ΔWI, n = 8) determined the bleaching efficacy of treatments. Enamel microhardness (Knoop, n = 8), morphology, and composition (SEM/EDS, n = 4) were also evaluated. Enamel/dentin discs adapted to artificial pulp chambers (n = 8) were used for trans-amelodentinal cytotoxicity tests. Following the treatments, the extracts (culture medium + bleaching gel components diffused through the discs) were collected and applied to odontoblast-like MDPC-23 cells, which were assessed concerning their viability (alamarBlue, n = 8; Live/Dead, n = 4), oxidative stress (n = 8), and morphology (SEM). The amount of H2O2 in the extracts was also determined (leuco crystal violet/peroxidase, n = 8). The numerical data underwent one-criterion variance analysis (one-way ANOVA), followed by Tukey's test, at a 5% significance level. RESULTS: Regarding the ΔE00, no difference was observed among groups 2TiF4, 6TiF4, and PC (p > 0.05). The ΔWI was similar between groups 2TiF4 and PC (p > 0.05). The ΔWI of group 6TiF4 was superior to PC (p < 0.05), and group 10TiF4 achieved the highest ΔE00 and ΔWI values (p < 0.05). Besides limiting enamel microstructural changes compared to PC, group 10TiF4 significantly increased the hardness of this mineralized dental tissue. The highest cellular viability occurred in 10TiF4 compared to the other bleached groups (p < 0.05). Trans-amelodentinal H2O2 diffusion decreased in groups 2TiF4, 6TiF4, and 10TiF4 in comparison with PC (p < 0.05). CONCLUSION: Coating enamel with a PPol containing TiF4 before applying a 35% BG may increase enamel microhardness and esthetic efficacy and reduce the trans-amelodentinal cytotoxicity of conventional in-office tooth bleaching. The PPol containing 10 mg/mL of TiF4 promoted the best outcomes.


Subject(s)
Tooth Bleaching Agents , Tooth Bleaching , Hydrogen Peroxide/chemistry , Tooth Bleaching Agents/pharmacology , Dentin , Tooth Bleaching/adverse effects , Dental Enamel
16.
J Dent ; 143: 104902, 2024 04.
Article in English | MEDLINE | ID: mdl-38432352

ABSTRACT

OBJECTIVE: To investigate the effect of tooth whitening on biomechanical properties of vacuum-formed retainers (VFRs). METHODS: Using a split-mouth, randomised controlled trial design, thirty participants were randomly allocated to receive whitening on either the upper or the lower arch, using 10 % carbamide peroxide for two weeks. Biomechanical properties such as hardness, tensile strength, and surface roughness were assessed two weeks after whitening was completed. RESULTS: Tensile strength of the whitening arch (mean ± SD: 40.93 ± 3.96 MPa) was significantly lower than that of the control (47.40 ± 5.03 MPa) (difference 6.47 MPa, 95 % CI 4.51 - 8.42, p < 0.001). Hardness and internal roughness of the whitening arch (VHN = 14.63 ± 2.29 N/mm2 and Ra = 1.33 ± 0.35 µm, respectively) were significantly greater than those of the control (12.22 ± 1.86 N/mm2 and 0.96 ± 0.29 µm, respectively) (differences 2.41 N/mm2, 95 % CI 1.56 - 3.25, p < 0.001 and 0.37 µm, 95 % CI 0.23 - 0.51, p < 0.001, respectively). The whitening arch showed greater tooth colour change (ΔE = 6.00 ± 3.32) than the control (ΔE = 2.50 ± 1.70) (difference = 3.50, 95 % CI 2.43 - 4.56, p < 0.001). CONCLUSIONS: Based on this short-term study, marked tooth colour change was achieved by whitening with VFRs as the whitening trays, but this changed the VFRs' biomechanical properties, including a decrease in tensile strength and an increase in hardness and internal roughness. CLINICAL SIGNIFICANCE: The application of carbamide peroxide in VFRs may compromise their mechanical properties.


Subject(s)
Tooth Bleaching Agents , Tooth Bleaching , Tooth , Humans , Carbamide Peroxide , Vacuum , Tooth Bleaching Agents/pharmacology , Urea , Peroxides/pharmacology , Hydrogen Peroxide/pharmacology , Drug Combinations
17.
J Esthet Restor Dent ; 36(7): 1029-1037, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38475979

ABSTRACT

OBJECTIVES: Evaluate the bleaching efficacy (BE) and tooth sensitivity (TS) of in-office bleaching using different application tips. METHODS: Forty-eight participants were selected (split-mouth), one to receive bleaching with an attached brush tip and one with a conventional tip. The procedure was performed with Whiteness Automixx Plus 35%. The BE was evaluated at the beginning, weekly, one and 12 months post-bleaching with a Vita Easyshade spectrophotometer (ΔE*ab, ΔE00, and WID) and with Vita classical A1-D4 and Vita Bleachedguide shade guides units (ΔSGU). Absolute risk and intensity of TS were recorded using the Visual Analogue Scale. The equivalence of BE was analyzed using the two one-sided t-tests for paired samples. The absolute risk of TS was evaluated using the McNemar test, and the TS intensity was measured with the paired t test (α = 0.05). RESULTS: The equivalence of BE was observed for both groups in all color evaluations (p > 0.05). A lower absolute risk and intensity of TS were observed for the attached brush tip when compared with the conventional tip (p < 0.003 and p < 0.0001). CONCLUSION: Using an attached brush tip showed the same BE as a conventional tip. However, for the attached brush tip, there was a reduction in TS. CLINICAL SIGNIFICANCE: The applicator-attached brush tip is recommended for in-office dental bleaching, because of the possible reduction in risk and intensity of TS.


Subject(s)
Dentin Sensitivity , Hydrogen Peroxide , Tooth Bleaching , Humans , Dentin Sensitivity/prevention & control , Tooth Bleaching/methods , Female , Adult , Male , Tooth Bleaching Agents , Young Adult
18.
Heliyon ; 10(3): e25833, 2024 Feb 15.
Article in English | MEDLINE | ID: mdl-38371984

ABSTRACT

Objectives: The objective of this umbrella review is to evaluate the efficacy and adverse effects of different teeth whitening techniques in-office (IO) and at-home (AH), regarding chromatic changes and teeth sensitivity. Materials and methods: The search was carried out from several databases. The included studies were all systematic reviews with or without meta-analysis of RCT or quasi-RCT. The participants were patients that underwent external dental bleaching in permanent vital teeth. The interventions were in-office (IO) bleaching techniques and at-home (AT) bleaching techniques with different bleaching agents and concentrations. Results: The search resulted in a total of 257 articles, and 28 SR were included in the qualitative analysis and nine in the quantitative analysis. There is no difference between in-office and at-home techniques in terms of color change (p = 0.95) and post-treatment sensitivity (p = 0.85). There is similarity risk and intensity of teeth sensitivity between AH and IO bleaching. IO bleaching with light-activated systems with low concentrations of bleaching agent showed similar results to IO bleaching techniques with high concentrated bleaching gels. With the application of the criteria of the AMSTAR 2 tool, the reviews were considered critically low to high. Conclusions: There are no significant differences in terms of color change between the different bleaching techniques compared. Teeth sensitivity is always present regardless of the technique used. The use of light activation systems did not increase the intensity and risk of post-operative sensitivity.

19.
Odontology ; 2024 Feb 17.
Article in English | MEDLINE | ID: mdl-38367067

ABSTRACT

The aim of this in vitro study was to evaluate the efficiency of diode laser-activated bleaching systems for color change of teeth. 75 extracted teeth were studied in five different bleaching protocols. Group 1: diode laser 445 nm, 320 µm fiber, 0.5W, continuous wave mode, dose 53 J/cm2. Group 2: diode laser 970 nm, 320 µm fiber, 1W, continuous wave mode, dose 106.10 J/cm2. Group 3: diode laser 940 nm, bleaching handpiece, 7W, continuous wave mode, dose 105 J/cm2. Group 4: diode laser 940 nm, 300 µm fiber, 2W, continuous wave mode, dose 47.16 J/cm2. Group 5: bleaching process without laser activation. In groups 1, 2 and 5, teeth were bleached with Perfect Bleach Office + and in groups 3 and 4, LaserWhite20 bleaching gel was used. Tooth color was determined immediately after the bleaching process using a spectrophotometer. Color change data on the CIE L * a * b* system was analyzed statistically by the one-way ANOVA and Tukey's HSD test. All bleaching procedures resulted in a change of color. All laser groups (∆E * ab > 3) have statistically larger ∆E * ab values than the control group (∆E * ab = 0.73) (p < 0.05). The diode laser 445 nm has the largest ∆E * ab value (∆E * ab = 4.65) and results in a significantly higher color difference than all other groups. In terms of color score difference in VITA Shades, all laser-activated groups lead to a lightening effect while the control group leads to only a slight lightening effect. The diode laser 445 nm produced the greatest color difference. Laser-activated bleaching is more effective than conventional bleaching without light activation. The diode laser 445 nm performs best in this in vitro study.

20.
J Esthet Restor Dent ; 2024 Feb 14.
Article in English | MEDLINE | ID: mdl-38353378

ABSTRACT

OBJECTIVE: Assess color alteration and hydrogen peroxide (HP) penetration in human and bovine teeth using various in-office bleaching protocols with different application times. MATERIALS AND METHODS: Thirty healthy human premolars and 30 healthy bovine incisors were divided into five groups and subjected to different bleaching protocols: 2 × 15 min, 1 × 30 min, 2 × 20 min, or 1 × 40 min, with a control group for each tooth type. All teeth were treated with 35% HP gel. Color alteration was measured using digital spectrophotometry before and 1 week after bleaching. HP concentration within the pulp was determined via UV-Vis spectrophotometry. Statistical analysis included one-way ANOVA, Tukey's, and Dunnett's tests (α = 0.05). RESULTS: All groups exhibited significant color alteration, with no statistically differences among them (p > 0.05). However, significant differences were observed when compared with their respective control groups (p < 0.05). HP penetration into the pulp was evident in all bleached teeth compared to the control groups (p < 0.05), with the 2 × 20 group showing the highest HP levels within the pulp cavity, irrespective of tooth type (p < 0.05). CONCLUSION: A simplified 1 × 30-min protocol can be recommended as it effectively maintains color alteration and HP penetration, irrespective of whether human or bovine teeth. CLINICAL SIGNIFICANCE: This study suggests that an in-office dental bleaching protocol using a 1 × 30-min session is recommended, as it ensures both effective color change and no increase in the amount of HP penetration.

SELECTION OF CITATIONS
SEARCH DETAIL
...