Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 2.154
Filter
1.
Artif Organs ; 2024 Jul 11.
Article in English | MEDLINE | ID: mdl-38989991

ABSTRACT

BACKGROUND: Significant tricuspid regurgitation (TR) is a predictor of right heart failure (RHF) and increased mortality following left ventricular assist device (LVAD) implantation, however the benefit of tricuspid valve surgery (TVS) at the time of LVAD implantation remains unclear. This study compares early and late mortality and RHF outcomes in patients with significant TR undergoing LVAD implantation with and without concomitant TVS. METHODS: A systematic search of four electronic databases was conducted for studies comparing patients with moderate or severe TR undergoing LVAD implantation with or without concomitant TVS. Meta-analysis was performed for primary outcomes of early and late mortality and RHF. Secondary outcomes included rate of stroke, renal failure, hospital and ICU length of stay. An overall survival curve was constructed using aggregated, reconstructed individual patient data from Kaplan-Meier (KM) curves. RESULTS: Nine studies included 575 patients that underwent isolated LVAD and 308 patients whom received concomitant TVS. Both groups had similar rates of severe TR (46.5% vs. 45.6%). There was no significant difference seen in risk of early mortality (RR 0.90; 95% CI, 0.57-1.42; p = 0.64; I2 = 0%) or early RHF (RR 0.82; 95% CI, 0.66-1.19; p = 0.41; I2 = 57) and late outcomes remained comparable between both groups. The aggregated KM curve showed isolated LVAD to be associated with overall increased survival (HR 1.42; 95% CI, 1.05-1.93; p = 0.023). CONCLUSIONS: Undergoing concomitant TVS did not display increased benefit in terms of early or late mortality and RHF in patients with preoperative significant TR. Further data to evaluate the benefit of concomitant TVS stratified by TR severity or by other predictors of RHF will be beneficial.

2.
Article in English | MEDLINE | ID: mdl-38984815

ABSTRACT

OBJECTIVES: To describe evolving demographic trends and early outcomes in patients undergoing triple-valve surgery in the UK, between 2000-2019. METHODS: We planned a retrospective analysis of national registry data including patients undergoing triple valve surgery for all aetiologies of disease. We excluded patients in a critical preoperative state and those with missing admission dates. The study cohort was split into 5 consecutive 4-year cohorts (groups A, B, C, D and E). The primary outcome was in-hospital mortality, and secondary outcomes included prolonged admission, re-exploration for bleeding, postoperative stroke and postoperative dialysis. Binary logistic regression models were used to establish independent predictors of mortality, stroke, postoperative dialysis and re-exploration for bleeding in this high-risk cohort. RESULTS: We identified 1,750 patients undergoing triple-valve surgery in the UK between 2000-2019. Triple valve surgery represents 3.1% of all patients in the dataset. Overall mean age of patients was 68.5 years ±12, having increased from 63 years ±12 in group A to 69 years ±12 in group E (p < 0.001). Overall in-hospital mortality rate was 9%, dropping from 21% in group A to 7% in group E (p < 0.001). Overall rates of re-exploration for bleeding (11%, p = 0.308) and postoperative dialysis (11%, p = 0.066) remained high across the observed time period. Triple valve replacement, redo sternotomy and poor preoperative left ventricular ejection fraction emerged as strong independent predictors of mortality. CONCLUSIONS: Triple valve surgery remains rare in the UK. Early postoperative outcomes for triple valve surgery have improved over time. Redo sternotomy is a significant predictor of mortality. Attempts should be made to repair the mitral and/or tricuspid valves where technically possible.

4.
Article in English | MEDLINE | ID: mdl-38985216

ABSTRACT

Rheumatic heart disease (RHD) is still a major health problem, especially in low- to mid-income countries, leading premature deaths owing to valvular disease. Although left-sided valvular involvement is most commonly seen in RHD, the tricuspid valve can also be affected. However, there is a lack of information about the prognostic value of primary tricuspid valve (TV) disease in RHD. This study aimed to determine the impact of TV disease on clinical outcome in RHD. This prospective study enrolled patients with rheumatic mitral valve disease (MVD) referred to a tertiary center for management of heart valve disease. Primary rheumatic TV disease was defined by echocardiographic features including thickening of leaflets associated with some degree of restricted mobility. Patients with rheumatic TV disease were matched to patients with MVD using 1:1 genetic matching algorithm that maximized balance of baseline covariates prior to exploring outcome differences. The main outcome was either need for MV replacement or death. Among 694 patients eligible for the study, age of 47 ± 13 years, 84% female, 39 patients (5.6%) had rheumatic TV disease. After excluding patients with incomplete data, 33 patients with TV disease were matched to 33 controls based on age, right-sided heart failure, atrial fibrillation, and MV area. During a mean follow-up of 42 months (median 28, IQR 8 to 71 months), 32 patients (48.5%) experienced adverse events, including 6 cardiovascular deaths and 26 patients who underwent surgery for mitral valve replacement. The adjusted analysis demonstrated a significant association between TV disease and the outcome, with a hazard ratio (HR) of 3.386 (95% CI 1.559-7.353; P = 0.002) in the genetic matched cohort with balance on baseline covariates of interest. The model exhibited good discriminative ability, as indicated by a C-statistic of 0.837. In patients with rheumatic mitral valve disease, rheumatic TV disease significantly increased risk of adverse events compared with matched controls. The involvement of TV may express overall disease severity that adversely affects clinical outcome.

5.
Future Cardiol ; : 1-6, 2024 Jul 08.
Article in English | MEDLINE | ID: mdl-38975696

ABSTRACT

One of the most common complications of tricuspid valve replacement is atrioventricular block (AVB), often requiring permanent pacing. The endocardial pacemaker lead, placed in the right ventricle, may sometimes interfere with the implanted prosthesis, causing its early dysfunction and the need for alternative sites of pacing. To the best of our knowledge, we present the first case of a successful combined percutaneous procedure consisting of the implantation of two leads in the coronary sinus for univentricular bifocal pacing and a transcatheter tricuspid valve-in-valve implantation in a young patient with severe dysfunction of the tricuspid bioprosthesis, requiring permanent pacing for a postsurgical complete atrioventricular block.


Tricuspid valve replacement with surgery can often lead to cardiac rhythm disorders requiring a permanent pacemaker. This device may occasionally damage the tricuspid prosthesis. We present the first case of a combined procedure of tricuspid valve replacement and device implantation distant from the prosthesis without the need for a surgical approach in a young patient with severe tricuspid prosthesis malfunctioning and permanent pacing.

6.
JACC Case Rep ; 29(14): 102393, 2024 Jul 17.
Article in English | MEDLINE | ID: mdl-38973814

ABSTRACT

Transcatheter tricuspid valve replacement (TTVR) is an increasingly used treatment technique for patients with severe tricuspid regurgitation (TR). Currently, available data from international registries and randomized controlled trials provide outcome data until a maximum follow-up of 2 years after the procedure. This case report presents 4-year follow-up data for an 84-year-old woman who underwent TTVR for torrential TR in 2019. The patient experienced durable TR reduction, symptomatic improvement, right ventricular reverse remodeling, and substantial improvement in liver and kidney function.

7.
Cureus ; 16(6): e61709, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38975395

ABSTRACT

Papillary fibroelastomas (PFEs) are rare benign cardiac tumors typically arising from the valvular endocardium, often affecting the aortic and mitral valves. They can range from asymptomatic to causing severe thromboembolic complications like stroke. This article presents a case of a tricuspid valve PFE in an 81-year-old patient with severe multi-vessel coronary artery disease. Transthoracic echocardiography revealed a mass on the tricuspid valve, confirmed by cardiac MRI. The patient underwent surgical excision, and histopathology confirmed the PFE diagnosis. The case highlights the importance of multimodal imaging in diagnosis and individualized treatment strategies for valvular heart tumors.

8.
Article in English | MEDLINE | ID: mdl-38970594

ABSTRACT

3-dimensional (3D) intracardiac echocardiography (ICE) is emerging as a promising complement and potential alternative to transesophageal echocardiography for imaging guidance in structural heart interventions. To establish standardized practices, our multidisciplinary expert position statement serves as a comprehensive guide for the appropriate indications and utilization of 3D-ICE in various structural heart procedures. The paper covers essential aspects such as the fundamentals of 3D-ICE imaging, basic views, and workflow recommendations specifically tailored for ICE-guided structural heart procedures, such as transeptal puncture, device closure of intracardiac structures, and transcatheter mitral and tricuspid valve interventions. Current challenges, future directions, and training requirements to ensure operator proficiency are also discussed, thereby promoting the safety and efficacy of this innovative imaging modality to support expanding its future clinical applications.

9.
Article in English | MEDLINE | ID: mdl-38887842

ABSTRACT

INTRODUCTION: Four-dimensional (4D) intracardiac echocardiography (ICE) is a novel cardiac imaging modality that has been applied to various workflows, including catheter ablation, tricuspid valve repair, and left atrial appendage occlusion (LAAO). The use of this type of advanced ICE imaging may ultimately allow for the replacement of transesophageal echocardiography (TEE) for LAAO, providing comparable imaging quality while eliminating the need for general anesthesia. METHODS: Based on our initial clinical experience with 4D ICE in LAAO, we have developed an optimized workflow for the use of the NUVISION™ 4D ICE Catheter in conjunction with the GE E95 and S70N Ultrasound Systems in LAAO. In this manuscript, we provide a step-by-step guide to using 4D ICE in conjunction with compatible imaging consoles. We have also evaluated the performance of 4D ICE with the NUVISION Ultrasound Catheter versus TEE in one LAAO case and present those results here. RESULTS: In our comparison of 4D ICE using our optimized workflow with TEE in an LAAO case, ICE LAA measurements were similar to those from TEE. The best image resolution was seen via ICE in 2-dimensional and multislice modes (triplane and biplane). The FlexiSlice multiplanar reconstruction tool, which creates an en-face image derived from a 4D volume set, also provided valuable information but yielded slightly lower image quality, as expected for these volume-derived images. For this case, comparable images were obtained with TEE and ICE but with less need to reposition the ICE catheter. CONCLUSION: The use of optimized 4D ICE catheter workflow recommendations allows for efficient LAAO procedures, with higher resolution imaging, comparable to TEE.

10.
Article in English | MEDLINE | ID: mdl-38890085

ABSTRACT

This article is the eighth in an annual series reviewing the research highlights of the year pertaining to the subspecialty of perioperative echocardiography for the Journal of Cardiothoracic and Vascular Anesthesia. The authors thank the editor-in-chief, Dr Kaplan, and the editorial board for the opportunity to continue this series. In most cases, these will be research articles targeted at the perioperative echocardiographic diagnosis and treatment of patients after cardiothoracic surgery; but in some cases, the articles will target the use of perioperative echocardiography in general.

11.
J Clin Med ; 13(11)2024 May 27.
Article in English | MEDLINE | ID: mdl-38892855

ABSTRACT

Background. Severe tricuspid valve (TV) disease has a strong association with right ventricle dysfunction, heart failure and mortality. Nevertheless, surgical indications for isolated TV disease are still uncommon. The purpose of this study is to analyze outcomes of patients undergoing minimally invasive isolated TV surgery (ITVS). Methods. Data of patients undergoing right mini-thoracotomy ITVS were prospectively collected. A subgroup analysis was performed on late referral patients. Five-year survival was assessed using the Kaplan-Meier survival estimate. Results. Eighty-one consecutive patients were enrolled; late referral was recorded in 8 out of 81 (9.9%). No cases of major vascular complications nor of stroke were reported. A 30-day mortality was reported in one patient (1.2%). Five-year Kaplan-Meier survival analysis revealed a significant difference between late referral patients and the control group (p = 0.01); late referral and Euroscore II were found to be significantly associated with reduced mid-term survival (p = 0.005 and p = 0.01, respectively). Conclusions. To date, perioperative mortality in patients undergoing ITVS is still consistently high, even in high-volume, high-experienced centres, and this accounts for the low rate of referral. Results from our report show that, with proper multidisciplinary management, appropriate pre-operative screening, and allocation to the safest approach, ITVS may offer better results than expected.

12.
Ann Med Surg (Lond) ; 86(6): 3325-3329, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38846821

ABSTRACT

Background: This study aims to present the early and mid-term outcomes of combining minimally invasive mitral valve surgery (MIMVS) with tricuspid valve repair (TVR) at the authors' centre. Methods: From January 2017 to March 2022, our centre treated a total of 67 patients with both MIMVS and TVR. Among these patients, 41 were women (61.2%), and 26 were men (38.8%). The average Euro SCORE II was 2.67±1.54%, and the patients had an average follow-up period of 25.45±16.2 months. Results: Pre-discharge echocardiography revealed no or mild TR in 82.8% of cases. The overall 30-day mortality rate was 4.5%, with 3 deaths. Five-year survival was 94.5%±3.2%. In patients with mild or moderate preoperative tricuspid regurgitation (TR), the 5-year survival rate was 95.7%±4.3%, while for those with severe TR, it was 93.7%±4.5% (P=0.947). Conclusions: The authors' 5-year experience demonstrates that the combination of MIMVS and TVR can be routinely performed with favourable perioperative and postoperative outcomes in patients undergoing non-high-risk surgery. Additionally, there is no significant difference in five-year survival between the severe TR and mild to moderate TR groups preoperatively.

13.
Curr Cardiol Rep ; 26(6): 459-474, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38884853

ABSTRACT

PURPOSE OF REVIEW: Patients with severe tricuspid regurgitation (TR) are at risk for significant morbidity and mortality. Transcatheter tricuspid valve interventions (TTVI) may offer patients less invasive treatment alternatives to surgery. This review evaluates the most common class of device currently used worldwide to treat TR, tricuspid transcatheter edge-to-edge repair (T-TEER) and orthotopic transcatheter tricuspid valve replacement (TTVR), both of which are now approved in the USA and Europe. RECENT FINDINGS: The first pivotal randomized clinical trial, TRILUMINATE, demonstrated that T-TEER can safely reduce TR and is associated with improved health status outcomes. However, results of this trial have raised questions about whether this device can provide sufficient TR reduction to impact clinical outcomes. Orthotopic TTVR has recently gained attention with initial data suggesting near-complete TR elimination. The current review examines the technical features and anatomic limitations of the most commonly used devices for T-TEER and orthotopic TTVR, discusses the current clinical data for these devices, and offers a theoretical construct for device selection.


Subject(s)
Cardiac Catheterization , Heart Valve Prosthesis Implantation , Tricuspid Valve Insufficiency , Tricuspid Valve , Humans , Tricuspid Valve Insufficiency/surgery , Cardiac Catheterization/methods , Cardiac Catheterization/instrumentation , Tricuspid Valve/surgery , Heart Valve Prosthesis Implantation/methods , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis , Treatment Outcome , Randomized Controlled Trials as Topic
14.
Cureus ; 16(5): e61059, 2024 May.
Article in English | MEDLINE | ID: mdl-38915969

ABSTRACT

Transcatheter tricuspid valve intervention (TTVI) has emerged as a promising alternative for patients with severe tricuspid regurgitation who are deemed high-risk for surgery. With advancements in device design and delivery systems, TTVI has shown promising outcomes in reducing tricuspid regurgitation severity and improving symptoms in selected patients. Paravalvular leaks (PVLs) are one of the most common complications faced, which can significantly contribute to patients' morbidity and mortality. Percutaneous PVL closure represents a minimally invasive approach to address this issue, but its efficacy and safety in the context of transcatheter tricuspid valve-in-ring implantation require further elucidation. We describe the case of a 44-year-old lady with a history of rheumatic valve disease status post-tricuspid valve annuloplasty with an incomplete ring who presented to cardiology clinics with symptomatic torrential tricuspid regurgitation. Due to the high risk of surgical reintervention secondary to severe right ventricular (RV) failure, she was denied surgical intervention. Therefore, she underwent transcatheter tricuspid valve-in-ring (TVIR) implantation with a 26 mm MyVal (Meril Life Sciences Pvt Ltd., Vapi, GJ, IND), which was complicated by a residual severe tricuspid paravalvular regurgitation. The defect was subsequently closed by a dedicated Occlutech PVL device (Occlutech, Helsingborg, SWE) measuring 18 mm x 10 mm. Post which, the patient had trivial tricuspid regurgitation and significant improvement in signs and symptoms with subsequent follow-up.

15.
Cureus ; 16(5): e61061, 2024 May.
Article in English | MEDLINE | ID: mdl-38915989

ABSTRACT

The management of acute chest syndrome (ACS) in sickle cell disease occurring concurrently with pulmonary embolism resulting from tricuspid valve endocarditis poses an atypical challenge. We present a case in which this complex interaction occurs and the prompt interventions that were utilized to give the best possible outcome.

16.
Cardiol Clin ; 42(3): 351-360, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38910020

ABSTRACT

Echocardiography, in all its forms (transthoracic echocardiography [TTE], transesophageal echocardiography [TEE], and intracardiac echocardiography [ICE]), is pivotal for the evaluation, guidance, and follow-up of transcatheter tricuspid edge-to-edge repair (TV-TEER) therapies. Although two-dimensional (2D) echocardiography remains essential, three-dimensional (3D) echo with multiplanar reconstruction (MPR) has revolutionized the field of structural imaging. In addition, the advent of 3D ICE has added an important modality to the imaging toolbox, particularly helpful when intraprocedural TEE images are challenging. In this review, we provide a detailed, step-by-step approach for advanced echocardiographic guidance of TV-TEER using 3D MPR.


Subject(s)
Cardiac Catheterization , Echocardiography, Three-Dimensional , Tricuspid Valve Insufficiency , Tricuspid Valve , Humans , Tricuspid Valve/diagnostic imaging , Tricuspid Valve/surgery , Cardiac Catheterization/methods , Tricuspid Valve Insufficiency/surgery , Tricuspid Valve Insufficiency/diagnostic imaging , Echocardiography, Three-Dimensional/methods , Echocardiography, Transesophageal/methods , Ultrasonography, Interventional/methods , Echocardiography/methods
17.
Am J Cardiol ; 2024 Jun 17.
Article in English | MEDLINE | ID: mdl-38897265

ABSTRACT

Severe tricuspid regurgitation remains largely undertreated given limited treatment options. Transcatheter tricuspid valve interventions have emerged as a promising therapy for these patients, and the TRISCEND II pivotal trial is the first randomized controlled trial to evaluate transcatheter tricuspid valve replacement (TTVR). The TRISCEND II pivotal trial studies the transcatheter EVOQUE (Edwards Lifesciences, Irvine, California) tricuspid valve replacement system using a United States Food and Drug Administration Breakthrough Device Designation-a program intended to provide timely access to medical devices by speeding up development, assessment, and review. The TRISCEND II trial is a prospective, multicenter trial that randomizes patients with symptomatic severe tricuspid regurgitation to treatment with either TTVR in conjunction with optimal medical therapy or optimal medical therapy alone. The trial's novel 2-phase design evaluates 30-day safety and 6-month effectiveness end points for the first 150 patients in the initial phase and a 1-year safety and effectiveness end point for the full cohort of 400 patients in the second phase. The TRISCEND II trial's 2-phase trial design provided an opportunity for early review and led to the first commercial approval of a TTVR system. In conclusion, the design of the TRISCEND II trial will likely inform future transcatheter tricuspid device trials.

18.
Eur J Cardiothorac Surg ; 66(1)2024 Jul 01.
Article in English | MEDLINE | ID: mdl-38897657

ABSTRACT

OBJECTIVES: This study aimed to provide comprehensive morphological descriptions of the morphology of the tricuspid valve and to evaluate if a novel echocardiography-based tricuspid valve nomenclature can also be understood anatomically. METHODS: Tricuspid valves of 60 non-embalmed human body donors without a medical history of pathologies or macroscopic malformations of the heart were included. Length, height and surface area of leaflets were measured. The valves were morphologically classified according to a novel echocardiography-based classification, in which 6 types are distinguished: classic 3-leaflet configuration, bicuspid valves, valves with 1 leaflet split into 2 scallops or leaflets and valves with 2 leaflets divided into 2 scallops or leaflets. RESULTS: We found a true 3-leaflet configuration in only 19 (31.7%) of valves. Five (8.3%) had a 2-leaflet configuration with a fused anterior and posterior leaflet. Of those, 3 had a divided septal leaflet. Four valves (6.7%) had a divided anterior leaflet, 17 (28.3%) had a divided posterior leaflet, 6 (10%) had a divided septal leaflet and 9 (15.0%) had 2 leaflets divided. Overall, 39 (65%) of valves have at least 1 leaflet that is divided. In 22 (36.7%) specimens, the leaflet was divided into true leaflets, and in 17 (28.3%) specimens, the leaflet was divided into scallops. In addition, we could identify 9 (15%) valves having 1 leaflet divided not only in 2 but 3 scallops or leaflets. CONCLUSIONS: This study provides further anatomical insight for the significant variability in the morphology of the tricuspid valve. By updating the understanding of its morphological characteristics, this study equips clinicians with valuable insights to effectively advance surgical and interventional treatment of tricuspid valves.


Subject(s)
Echocardiography , Tricuspid Valve , Humans , Tricuspid Valve/diagnostic imaging , Tricuspid Valve/anatomy & histology , Male , Female , Middle Aged , Aged , Adult , Echocardiography/methods , Tissue Donors , Young Adult
20.
Am J Cardiol ; 225: 89-97, 2024 Jun 17.
Article in English | MEDLINE | ID: mdl-38897268

ABSTRACT

Tricuspid valve replacement (TVR) with mechanical versus tissue valves remains a controversial subject. To evaluate the long-term effects of types of valves on patient-relevant outcomes, we performed a systematic review with meta-analysis of reconstructed time-to-event data of studies published by March 15, 2024 (according to referred the Reporting Items for Systematic Reviews and Meta-analyses guidelines). A total of 21 studies met our eligibility criteria and included 7,166 patients (mechanical: 2,495 patients, 34.8%). Patients who underwent mechanical TVR had a lower risk of death than those who received a tissue valve (hazard ratio [HR] 0.77, 95% confidence interval [CI] 0.70 to 0.84, p <0.001). Mechanical TVR was associated with lifetime gain, as evidenced by the restricted mean survival time, which was 2.2 years longer in patients who underwent TVR with mechanical valves (12.4 vs 10.2 years, p <0.001). Our landmark analysis for reoperations revealed the following: from the time point 0 to 7 years, we found no difference in the risk of reoperation between mechanical and tissues valves (HR 0.98, 95% CI 0.60 to 1.61, p = 0.946); however, from the time point 7 years onward, we found that mechanical TVR had a lower risk of reoperation in the follow-up (HR 0.24, 95% CI 0.08 to 0.72, p = 0.001). The meta-regression analysis demonstrated a modulating effect of atrial fibrillation on the association between mechanical valves and mortality; the HRs for all-cause death tended to decrease in the presence of populations with a larger proportion of atrial fibrillation (p = 0.018). In conclusion, our results suggest that TVR with mechanical valves, whenever considered clinically reasonable and accepted by patients as an option, can offer a better long-term survival and lower risk of reoperation in the long run.

SELECTION OF CITATIONS
SEARCH DETAIL
...