1.
Int J Cardiol ; 414: 132394, 2024 Nov 01.
Article in English | MEDLINE | ID: mdl-39067525

ABSTRACT

BACKGROUND: Prevalence of bioprosthetic valve degeneration (BVD) is rising as the use of bioprosthetic aortic valves increases. Detecting early signs of BVD remains a challenge, with conventional imaging methods often failing to identify early deterioration stages. 18F-fuoride positron emission tomography (PET-CT) is an emerging technique that offers promising prospects to detect subclinical BVD. This study aimed to compare early PET parameters of fluoride uptake with echocardiographic hemodynamic parameters and compare outcomes according to anticoagulation in patients who received bioprosthetic valves. METHODS: This is a sub-study of the ANTIPRO clinical trial, which involved patients undergoing surgical aortic valve replacement (SAVR) with a porcine bioprosthesis and randomized them into anticoagulated and non-anticoagulated groups. Hemodynamic changes were assessed by transthoracic echocardiography (TTE), while 18F-fluoride PET-CT quantified fluoride uptake and divided the patients in two groups: high-uptake and low-uptake. Mean and maximum gradients by TTE at three years were compared between the two uptake groups. Fluoride uptake was also compared between the anticoagulated and control groups. RESULTS: We found no significant differences in transprosthetic gradients between high-uptake(21.4 ± 8.6 mmHg) and low-uptake(17.3 ± 11.2 mmHg.p = 0.244) PET-defined groups in this specific timeframe. Notably, anticoagulated patients exhibited significantly risk of higher fluoride uptake(OR = 4.34;95%CI:1.04-18.21.p = 0.045). CONCLUSIONS: No association was found between fluoride uptake and hemodynamic evaluation. Anticoagulation was associated with higher fluoride uptake. These findings highlight the emerging role of PET-CT in studying bioprosthetic aortic valves and emphasize the need for extended follow-up to evaluate the impact of anticoagulation on valve degeneration.


Subject(s)
Anticoagulants , Aortic Valve , Bioprosthesis , Heart Valve Prosthesis , Warfarin , Bioprosthesis/adverse effects , Humans , Female , Male , Heart Valve Prosthesis/adverse effects , Anticoagulants/administration & dosage , Aged , Warfarin/administration & dosage , Warfarin/pharmacokinetics , Warfarin/therapeutic use , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Fluorine Radioisotopes , Positron Emission Tomography Computed Tomography/methods , Middle Aged , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/diagnostic imaging , Follow-Up Studies , Prosthesis Failure , Positron-Emission Tomography/methods
2.
Braz J Cardiovasc Surg ; 39(4): e20230155, 2024 Jul 22.
Article in English | MEDLINE | ID: mdl-39038084

ABSTRACT

OBJECTIVE: This study aimed to compare hemodynamic performances and clinical outcomes of patients with small aortic annulus (SAA) who underwent aortic valve replacement by means of sutureless aortic valve replacement (SUAVR) or transcatheter aortic valve implantation (TAVI). METHODS: From 2015 to 2020, 622 consecutive patients with SAA underwent either SUAVR or TAVI. Through a 1:1 propensity score matching analysis, two homogeneous groups of 146 patients were formed. Primary endpoint: all cause-death at 36 months. Secondary endpoints: incidence of moderate to severe patient-prosthesis mismatch (PPM) and incidence of major adverse cardiovascular and cerebrovascular events (MACCEs). RESULTS: All-cause death at three years was higher in the TAVI group (SUAVR 12.2% vs. TAVI 21.0%, P=0.058). Perioperatively, comparable hemodynamic performances were recorded in terms of indexed effective orifice area (SUAVR 1.12 ± 0.23 cm2/m2 vs. TAVI 1.17 ± 0.28 cm2/m2, P=0.265), mean transvalvular gradients (SUAVR 12.9 ± 5.3 mmHg vs. TAVI 12.2 ± 6.2 mmHg, P=0.332), and moderate-to-severe PPM (SUAVR 4.1% vs. TAVI 8.9%, P=0.096). TAVI group showed a higher cumulative incidence of MACCEs at 36 months (SUAVR 18.1% vs. TAVI 32.6%, P<0.001). Pacemaker implantation (PMI) and perivalvular leak ≥ 2 were significantly higher in TAVI group and identified as independent predictors of mortality (PMI: hazard ratio [HR] 3.05, 95% confidence interval [CI] 1.34-6.94, P=0.008; PPM: HR 2.72, 95% CI 1.25-5.94, P=0.012). CONCLUSION: In patients with SAA, SUAVR and TAVI showed comparable hemodynamic performances. Moreover, all-cause death and incidence of MACCEs at follow-up were significantly higher in TAVI group.


Subject(s)
Aortic Valve Stenosis , Aortic Valve , Hemodynamics , Propensity Score , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/methods , Transcatheter Aortic Valve Replacement/mortality , Transcatheter Aortic Valve Replacement/adverse effects , Male , Female , Hemodynamics/physiology , Aged , Aged, 80 and over , Aortic Valve/surgery , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/mortality , Treatment Outcome , Sutureless Surgical Procedures/methods , Heart Valve Prosthesis , Retrospective Studies , Postoperative Complications , Heart Valve Prosthesis Implantation/methods , Risk Factors
3.
Article in English | MEDLINE | ID: mdl-39030151

ABSTRACT

OBJECTIVES: To investigate the incidence of intravalvular leak after aortic valve replacement with the Inspiris Resilia valve. DESIGN: This study was a retrospective chart review. SETTING: This study used data from a single tertiary care academic center. PARTICIPANTS: A total of 81 patient charts and echo images were reviewed. INTERVENTIONS: All patients underwent an aortic valve replacement using the Inspiris Resilia valve. Pediatric patients and patients receiving an aortic valve conduit were excluded. MEASUREMENTS AND MAIN RESULTS: Transesophageal echocardiography (TEE) images were reviewed independently by 2 echocardiographers for the incidence and severity of intravalvular leak after Inspiris Resilia valve placement. Outpatient follow-up imaging was then compared to intraoperative findings. Valve size and mean gradients were documented as well. Of the 81 TEEs that were reviewed, 56 (69.1%) were found to have a strut leak at the time of implantation. Among these 56 cases, 30 were classified as trace regurgitation, 21 as mild regurgitation, and 5 as moderate regurgitation. Only 1 case necessitated a return to cardiopulmonary bypass owing to persistent intravalvular leak. Follow-up transthoracic echocardiography reports were available for 50 of the patients with no persistent leaks. CONCLUSIONS: This pattern of intravalvular leak is unique to the Inspiris Resilia valve and is commonly found in the intraoperative period. While many hypotheses exist for the origin of this leak, the exact mechanism is unclear. Given the high frequency of this postprocedure finding, it is essential that intraoperative echocardiographers be able to distinguish this clinically insignificant leak based on its origin, severity, and direction and to provide appropriate recommendations to our surgical colleagues.

4.
Braz J Cardiovasc Surg ; 39(4): e20230088, 2024 Jul 22.
Article in English | MEDLINE | ID: mdl-39038027

ABSTRACT

INTRODUCTION: Diabetes mellitus (DM) in patients undergoing cardiac transcatheter or surgical interventions usually is correlated with poor outcomes. Transcatheter aortic valve implantation (TAVI) has been developed as a therapy choice for inoperable, high-, or intermediate-risk surgical patients with severe aortic stenosis (AS). OBJECTIVE: To evaluate the impact of DM and hemoglobin A1c (HbA1c) on outcomes and survival after TAVI. METHODS: Five hundred and fifty-two symptomatic severe AS patients who underwent TAVI, of whom 164 (29.7%) had DM, were included in this retrospective study. Follow-up was performed after 30 days, six months, and annually. RESULTS: The device success and risks of procedural-related complications were similar between patients with and without DM, except for acute kidney injury, which was more frequent in the DM group (2.4% vs. 0%, P=0.021). In-hospital and first-year mortality were similar between the groups (4.9% vs. 3.6%, P=0.490 and 15.0% vs. 11.2%, P=0.282, respectively). There was a statistical difference between HbA1c ≥ 6.5 and HbA1c ≤ 6.49 groups in total mortality (34.4% vs. 15.8%, P<0.001, respectively). The only independent predictors were Society of Thoracic Surgeons score (hazard ratio [HR] 1.28, 95% confidence interval [CI] 1.09-1.51; P=0.003) and HbA1c level ≥ 6.5 (HR 10.78, 95% CI 2.58-21.50; P=0.003) in multivariable logistic regression analysis. CONCLUSION: In this study, we conclude that DM was not correlated with an increased mortality risk or complication rates after TAVI. Also, it was shown that mortality was higher in patients with HbA1c ≥ 6.5, and it was an independent predictor for long-term mortality.


Subject(s)
Aortic Valve Stenosis , Diabetes Mellitus , Glycated Hemoglobin , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/mortality , Transcatheter Aortic Valve Replacement/adverse effects , Male , Female , Retrospective Studies , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/mortality , Aged, 80 and over , Aged , Treatment Outcome , Diabetes Mellitus/mortality , Glycated Hemoglobin/analysis , Risk Factors , Postoperative Complications/mortality , Time Factors , Severity of Illness Index , Hospital Mortality
5.
Braz J Cardiovasc Surg ; 39(4): e20230438, 2024 Jul 22.
Article in English | MEDLINE | ID: mdl-39038201

ABSTRACT

OBJECTIVES: The aims of the present study were to compare the long-term outcomes for ascending aortic dilatation and adverse aortic events after isolated aortic valve replacement between patients with bicuspid aortic valve (BAV) and tricuspid aortic valve ( TAV). METHODS: This retrospective study included 310 patients who had undergone isolated aortic valve replacement with an ascending aorta diameter ≤ 45 mm between January 2010 and September 2021. The patients were divided into BAV group (n=90) and TAV group (n=220). The differences in the dilation rate of the ascending aorta and long-term outcomes were analyzed. RESULTS: Overall survival was 89 ± 4% in the BAV group vs. 75 ± 6% in the TAV group at 10 years postoperatively (P=0.007), yet this difference disappeared after adjusting exclusively for age (P=0.343). The mean annual growth rate of the ascending aorta was similar between the two groups during follow-up (0.5 ± 0.6 mm/year vs. 0.4 ± 0.5 mm/year; P=0.498). Ten-year freedom from adverse aortic events was 98.1% in the BAV group vs. 95.0% in the TAV group (P=0.636). Multivariable analysis revealed preoperative ascending aorta diameter to be a significant predictor of adverse aortic events (hazard ratio: 1.76; 95% confidence interval: 1.33 to 2.38; P<0.001). CONCLUSION: Our study revealed that the long-term survival and the risks of adverse aortic events between BAV and TAV patients were similar after isolated aortic valve replacement. BAV was not a risk factor of adverse aortic events.


Subject(s)
Aorta , Aortic Valve , Bicuspid Aortic Valve Disease , Heart Valve Diseases , Heart Valve Prosthesis Implantation , Humans , Male , Female , Retrospective Studies , Bicuspid Aortic Valve Disease/surgery , Bicuspid Aortic Valve Disease/complications , Middle Aged , Aortic Valve/surgery , Aortic Valve/abnormalities , Aged , Heart Valve Prosthesis Implantation/mortality , Aorta/surgery , Heart Valve Diseases/surgery , Heart Valve Diseases/complications , Heart Valve Diseases/mortality , Tricuspid Valve/surgery , Disease Progression , Risk Factors , Treatment Outcome , Postoperative Complications
6.
Arq. bras. cardiol ; Arq. bras. cardiol;121(7): e20230622, jun.2024. tab, graf
Article in Portuguese | LILACS-Express | LILACS, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1563934

ABSTRACT

Resumo Fundamento Dados robustos sobre a curva de aprendizagem (LC) da substituição da válvula aórtica transcateter (TAVR) são escassos nos países em desenvolvimento. Objetivo Avaliar a LC da TAVR no Brasil ao longo do tempo. Métodos Analisamos dados do registro brasileiro de TAVR de 2008 a 2023. Pacientes de cada centro foram numerados cronologicamente em número sequencial de caso (NSC). A LC foi realizada usando um spline cúbico restrito ajustado para o EuroSCORE-II e o uso de próteses de nova geração. Ainda, os desfechos hospitalares foram comparados entre grupos definidos de acordo com o nível de experiência, com base no NSC: 1º ao 40º caso (experiência inicial), 41º ao 80º caso (experiência básica), 81º ao 120º caso (experiência intermediária) e 121º caso em diante (experiência alta). Análises adicionais foram conduzidas de acordo com o número de casos tratados antes de 2014 (>40 e ≤40 procedimentos). O nível de significância adotado foi p <0,05. Resultados Foram incluídos 3194 pacientes de 25 centros. A idade média foi 80,7±8,1 anos e o EuroSCORE II médio foi 7±7,1. A análise da LC demonstrou uma queda na mortalidade hospitalar ajustada após o tratamento de 40 pacientes. Um patamar de nivelamento na curva foi observado após o caso 118. A mortalidade hospitalar entre os grupos foi 8,6%, 7,7%, 5,9%, e 3,7% para experiência inicial, básica, intermediária e alta, respectivamente (p<0,001). A experiência alta foi preditora independente de mortalidade mais baixa (OR 0,57, p=0,013 vs. experiência inicial). Centros com baixo volume de casos antes de 2014 não mostraram uma redução significativa na probabilidade de morte com o ganho de experiência, enquanto centros com alto volume de casos antes de 2014 apresentaram uma melhora contínua após o caso de número 10. Conclusão Observou-se um fenômeno de LC para a mortalidade hospitalar do TAVR no Brasil. Esse efeito foi mais pronunciado em centros que trataram seus 40 primeiros casos antes de 2014 que naqueles que o fizeram após 2014.


Abstract Background Robust data on the learning curve (LC) of transcatheter aortic valve replacement (TAVR) are lacking in developing countries. Objective To assess TAVR's LC in Brazil over time. Methods We analyzed data from the Brazilian TAVR registry from 2008 to 2023. Patients from each center were numbered chronologically in case sequence numbers (CSNs). LC was performed using restricted cubic splines adjusted for EuroSCORE-II and the use of new-generation prostheses. Also, in-hospital outcomes were compared between groups defined according to the level of experience based on the CSN: 1st to 40th (initial-experience), 41st to 80th (early-experience), 81st to 120th (intermediate-experience), and over 121st (high-experience). Additional analysis was performed grouping hospitals according to the number of cases treated before 2014 (>40 and ≤40 procedures). The level of significance adopted was <0.05. Results A total of 3,194 patients from 25 centers were included. Mean age and EuroSCORE II were 80.7±8.1 years and 7±7.1, respectively. LC analysis demonstrated a drop in adjusted in-hospital mortality after treating 40 patients. A leveling off of the curve was observed after case #118. In-hospital mortality across the groups was 8.6%, 7.7%, 5.9%, and 3.7% for initial-, early-, intermediate-, and high-experience, respectively (p<0.001). High experience independently predicted lower mortality (OR 0.57, p=0.013 vs. initial experience). Low-volume centers before 2014 showed no significant decrease in the likelihood of death with gained experience, whereas high-volume centers had a continuous improvement after case #10. Conclusion A TAVR LC phenomenon was observed for in-hospital mortality in Brazil. This effect was more pronounced in centers that treated their first 40 cases before 2014 than those that reached this milestone after 2014.

9.
Circ Cardiovasc Interv ; 17(9): e013697, 2024 Sep.
Article in English | MEDLINE | ID: mdl-38837174

ABSTRACT

BACKGROUND: Cerebral embolic protection devices (EPDs) were developed to mitigate the risk of stroke during transcatheter aortic valve replacement (TAVR), but their benefit remains unproven. In the PROTECTED-TAVR trial (Stroke Protection With Sentinel During Transcatheter), EPD use did not reduce periprocedural stroke (primary study outcome) but led to a 62% reduction in the secondary end point of disabling stroke. Given these results, the impact of EPDs during TAVR remains unclear. METHODS: We used STS/ACC TVT registry data to examine the association between EPD use and a proxy for disabling stroke among transfemoral TAVR patients between January 2018 and June 2023. The primary outcome was in-hospital disabling stroke-defined as stroke associated with either in-hospital death or discharge to a nonhome location. We evaluated the association between EPD use and disabling stroke using instrumental variable analysis with a site-level preference for EPD use as the instrument-a quasi-experimental approach that can support causal inference. In addition, we performed a propensity score-based comparison using overlap weighting as a secondary analysis. RESULTS: The study population consisted of 414 649 patients of whom 53 389 (12.9%) received an EPD. The unadjusted rate of in-hospital disabling stroke was 0.7% among the EPD group and 0.9% in the no-EPD group. EPD use was associated with a reduction in disabling stroke in both instrumental variable analysis (relative risk, 0.87 [95% CI, 0.73-1.00]) and propensity-weighted analysis (odds ratio, 0.79 [95% CI, 0.70-0.90]) but was not associated with a reduction in nondisabling stroke. In subgroup analyses, the benefit of EPD was greater among those with versus without prior stroke (Pinteraction<0.05 for both instrumental variable and propensity-weighted analyses). CONCLUSIONS: In the largest study to date, among patients undergoing TAVR, EPD use was associated with a small, borderline significant reduction in stroke associated with death or discharge to a nonhome location (a proxy for disabling stroke) that is likely to be causal in nature. Taken together with previous mechanistic and clinical studies, these findings provide credible evidence that EPDs benefit patients undergoing TAVR.


Subject(s)
Aortic Valve Stenosis , Embolic Protection Devices , Registries , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/instrumentation , Transcatheter Aortic Valve Replacement/mortality , Male , Female , Aged, 80 and over , Aged , Risk Factors , Treatment Outcome , Risk Assessment , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/mortality , Aortic Valve Stenosis/physiopathology , Time Factors , United States/epidemiology , Hospital Mortality , Intracranial Embolism/prevention & control , Intracranial Embolism/etiology , Intracranial Embolism/mortality , Disability Evaluation , Stroke/prevention & control , Stroke/mortality , Stroke/etiology , Stroke/diagnosis , Protective Factors , Retrospective Studies
10.
Braz J Cardiovasc Surg ; 39(2): e20220436, 2024 Mar 01.
Article in English | MEDLINE | ID: mdl-38426701

ABSTRACT

INTRODUCTION: The aim of this study was to assess the impact of aortic angulation (AA) on periprocedural and in-hospital complications as well as mortality of patients undergoing Evolut™ R valve implantation. METHODS: A retrospective study was conducted on 264 patients who underwent transfemoral-approach transcatheter aortic valve replacement with self-expandable valve at our hospital between August 2015 and August 2022. These patients underwent multislice computer tomography scans to evaluate AA. Transcatheter aortic valve replacement endpoints, device success, and clinical events were assessed according to the definitions provided by the Valve Academic Research Consortium-3. Cumulative events included paravalvular leak, permanent pacemaker implantation, new-onset stroke, and in-hospital mortality. Patients were divided into two groups, AA ≤ 48° and AA > 48°, based on the mean AA measurement (48.3±8.8) on multislice computer tomography. RESULTS: Multivariable logistic regression analysis was performed to identify predictors of cumulative events, utilizing variables with a P-value < 0.2 obtained from univariable logistic regression analysis, including AA, age, hypertension, chronic renal failure, and heart failure. AA (odds ratio [OR]: 1.73, 95% confidence interval [CI]: 0.89-3.38, P=0.104), age (OR: 1.04, 95% CI: 0.99-1.10, P=0.099), hypertension (OR: 1.66, 95% CI: 0.82-3.33, P=0.155), chronic renal failure (OR: 1.82, 95% CI: 0.92-3.61, P=0.084), and heart failure (OR: 0.57, 95% CI: 0.27-1.21, P=0.145) were not found to be significantly associated with cumulative events in the multivariable logistic regression analysis. CONCLUSION: This study demonstrated that increased AA does not have a significant impact on intraprocedural and periprocedural complications of patients with new generation self-expandable valves implanted.


Subject(s)
Aortic Valve Stenosis , Heart Failure , Heart Valve Prosthesis , Hypertension , Kidney Failure, Chronic , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/methods , Aortic Valve/surgery , Aortic Valve Stenosis/surgery , Retrospective Studies , Treatment Outcome , Prosthesis Design , Kidney Failure, Chronic/etiology , Kidney Failure, Chronic/surgery , Heart Failure/surgery , Hypertension/etiology
11.
Braz J Cardiovasc Surg ; 39(2): e20230221, 2024 Mar 01.
Article in English | MEDLINE | ID: mdl-38426718

ABSTRACT

INTRODUCTION: Aortic valve replacement (AVR) is often recommended for patients with severe aortic stenosis or chronic aortic regurgitation. These conditions result in remodeling of the left ventricle, including increased interstitial fibrosis that may persist even after AVR. These structural changes impact left ventricular (LV) mechanics, causing compromised LV diameter to occur earlier than reduced LV ejection fraction (LVEF). The aim of this study was to examine the effect of left ventricular end-diastolic diameter (LVEDD) and its role in aortic expansion one year after AVR. METHODS: Sixty-three patients who underwent AVR were evaluated. All patients underwent standard transthoracic echocardiography, which included measurements of the ascending aorta, aortic root, LVEF, and LVEDD before the surgery and one year postoperatively. Correlations between these variables were calculated. RESULTS: All patients underwent AVR with either a mechanical or biological prosthetic aortic valve. Following AVR, there was a significant decrease in the dimensions of the ascending aorta and aortic root (both P=0.001). However, no significant changes were observed in LVEDD and LVEF. Correlations were found between the preoperative ascending aortic size and the preoperative and one-year postoperative LVEDD (r=0.419, P=0.001 and r=0.320, P=0.314, respectively). Additionally, there was a correlation between the postoperative ascending aortic size and the preoperative and one-year postoperative LVEDD (r=0.320, P=0.003 and r=0.136, P=0.335, respectively). CONCLUSION: The study findings demonstrate a significant correlation between the size of the aortic root and ascending aorta, before and after AVR. Additionally, a notable correlation was observed between postoperative LVEDD and the size of the aortic root.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Humans , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Heart Ventricles/surgery , Retrospective Studies , Aortic Valve Stenosis/surgery
12.
Rev. bras. cir. cardiovasc ; Rev. bras. cir. cardiovasc;39(2): e20220436, 2024. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1535538

ABSTRACT

ABSTRACT Introduction: The aim of this study was to assess the impact of aortic angulation (AA) on periprocedural and in-hospital complications as well as mortality of patients undergoing Evolut™ R valve implantation. Methods: A retrospective study was conducted on 264 patients who underwent transfemoral-approach transcatheter aortic valve replacement with self-expandable valve at our hospital between August 2015 and August 2022. These patients underwent multislice computer tomography scans to evaluate AA. Transcatheter aortic valve replacement endpoints, device success, and clinical events were assessed according to the definitions provided by the Valve Academic Research Consortium-3. Cumulative events included paravalvular leak, permanent pacemaker implantation, new-onset stroke, and in-hospital mortality. Patients were divided into two groups, AA ≤ 48° and AA > 48°, based on the mean AA measurement (48.3±8.8) on multislice computer tomography. Results: Multivariable logistic regression analysis was performed to identify predictors of cumulative events, utilizing variables with a P-value < 0.2 obtained from univariable logistic regression analysis, including AA, age, hypertension, chronic renal failure, and heart failure. AA (odds ratio [OR]: 1.73, 95% confidence interval [CI]: 0.89-3.38, P=0.104), age (OR: 1.04, 95% CI: 0.99-1.10, P=0.099), hypertension (OR: 1.66, 95% CI: 0.82-3.33, P=0.155), chronic renal failure (OR: 1.82, 95% CI: 0.92-3.61, P=0.084), and heart failure (OR: 0.57, 95% CI: 0.27-1.21, P=0.145) were not found to be significantly associated with cumulative events in the multivariable logistic regression analysis. Conclusion: This study demonstrated that increased AA does not have a significant impact on intraprocedural and periprocedural complications of patients with new generation self-expandable valves implanted.

13.
Rev. bras. cir. cardiovasc ; Rev. bras. cir. cardiovasc;39(2): e20230221, 2024. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1535544

ABSTRACT

ABSTRACT Introduction: Aortic valve replacement (AVR) is often recommended for patients with severe aortic stenosis or chronic aortic regurgitation. These conditions result in remodeling of the left ventricle, including increased interstitial fibrosis that may persist even after AVR. These structural changes impact left ventricular (LV) mechanics, causing compromised LV diameter to occur earlier than reduced LV ejection fraction (LVEF). The aim of this study was to examine the effect of left ventricular end-diastolic diameter (LVEDD) and its role in aortic expansion one year after AVR. Methods: Sixty-three patients who underwent AVR were evaluated. All patients underwent standard transthoracic echocardiography, which included measurements of the ascending aorta, aortic root, LVEF, and LVEDD before the surgery and one year postoperatively. Correlations between these variables were calculated. Results: All patients underwent AVR with either a mechanical or biological prosthetic aortic valve. Following AVR, there was a significant decrease in the dimensions of the ascending aorta and aortic root (both P=0.001). However, no significant changes were observed in LVEDD and LVEF. Correlations were found between the preoperative ascending aortic size and the preoperative and one-year postoperative LVEDD (r=0.419, P=0.001 and r=0.320, P=0.314, respectively). Additionally, there was a correlation between the postoperative ascending aortic size and the preoperative and one-year postoperative LVEDD (r=0.320, P=0.003 and r=0.136, P=0.335, respectively). Conclusion: The study findings demonstrate a significant correlation between the size of the aortic root and ascending aorta, before and after AVR. Additionally, a notable correlation was observed between postoperative LVEDD and the size of the aortic root.

14.
Arq. bras. cardiol ; Arq. bras. cardiol;121(5): e20230467, 2024. tab, graf
Article in Portuguese | LILACS-Express | LILACS | ID: biblio-1563904

ABSTRACT

Resumo Fundamento O implante percutâneo de bioprótese valvar aórtica (TAVI) consolidou-se como opção terapêutica da estenose aórtica de grau importante. Dados sobre as características evolutivas dos procedimentos e dos resultados obtidos com a técnica ao longo da última década, em escala nacional, são desconhecidos. Objetivos Analisar a tendência temporal referente ao perfil demográfico, características dos procedimentos e desfechos hospitalares de pacientes submetidos a TAVI na Rede D'Or São Luiz. Métodos Registro observacional envolvendo 29 instituições nacionais. Comparou-se características dos procedimentos realizados de 2012 a 2017 (Grupo 1) e de 2018 a 2023 (Grupo 2). Foram considerados significantes os resultados com valor de p < 0,05. Resultados Foram analisados 661 casos, 95 pertencentes ao Grupo 1 e 566 ao Grupo 2. A média de idade foi 81,1 anos. Observou-se no Grupo 1 maior prevalência de pacientes em classe funcional III ou IV e escore de risco > 8%. Foi mais frequente o emprego de anestesia geral, monitorização ecocardiográfica transesofágica e via de acesso por dissecção. Maior taxa de sucesso do procedimento (95,4% versus 89,5%; p = 0,018) foi aferida em implantes efetivados a partir de 2018, assim como menor mortalidade (3,9% versus 11,6%; p = 0,004) e necessidade de marcapasso definitivo (8,5% versus 17,9%; p = 0,008). Conclusões A análise temporal de 10 anos do Registro TAVIDOR demonstra uma queda na complexidade clínica dos pacientes. Além disso, o avanço para técnicas de implante minimalistas, somadas à evolução tecnológica dos dispositivos, podem ter contribuído para desfechos favoráveis dentre aqueles cujo implante ocorreu no último quinquênio.


Abstract Background Transcatheter aortic valve implantation (TAVI) has established itself as the preferential strategy to approach severe aortic stenosis. Information on procedural improvements and nationwide results obtained with the technique throughout the past decade are unknown. Objectives To assess the temporal variation of the demographic profile, procedural characteristics, and in-hospital outcomes of patients undergoing TAVI procedures at the Rede D'Or São Luiz. Methods Observational registry comprising 29 national institutions, comparing the characteristics of the TAVI procedures performed from 2012 to 2017 (Group 1) to those performed from 2018 to 2023 (Group 2). The statistical significance level adopted was p < 0.05. Results This study assessed 661 patients, 95 in Group 1 and 566 in Group 2, with a mean age of 81.1 years. Group 1 patients had a higher prevalence of New York Heart Association functional class III or IV and STS risk score > 8%. In addition, they more often underwent general anesthesia, transesophageal echocardiographic monitoring, and access through femoral dissection. Group 2 patients had a higher success rate of the TAVI procedure (95.4% versus 89.5%; p = 0.018), lower mortality (3.9% versus 11.6%; p = 0.004), and less often needed permanent pacemaker implantation (8.5% versus 17.9%; p = 0.008). Conclusions The 10-year temporal trends analysis of the TAVIDOR Registry shows a reduction in patients' clinical complexity over time. Furthermore, the advance to minimalistic implantation techniques, added to the technological evolution of the devices, may have contributed to the favorable outcomes observed among those whose implantation occurred in the last 5 years studied.

15.
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1565636

ABSTRACT

La valvulopatía tricuspídea es considerada frecuente y sobre todo en pacientes con afectación mitral, habiendo sido sostenidamente objeto de controversias, tanto en la selección de la correcta actuación terapéutica, como del momento apropiado de su ejecución. Aunque la válvula tricúspide es afectada por estenosis, predominantemente es asiento de lesión tipo insuficiencia, que significa paso retrógrado de sangre desde el ventrículo derecho (VD) a la aurícula derecha durante la sístole. Puede ser primaria (orgánica) o secundaria (funcional), relacionada a dilatación/disfunción ventricular derecha, dilatación anular, tracción de sus valvas e hipertensión arterial pulmonar. La ecocardiografía tridimensional (3D) y la resonancia magnética cardiaca al permitir cuantificar con mayor precisión el tamaño del VD y la función sistólica, han permitido actuaciones terapéuticas más tempranas y con mejores resultados, que incluyen la reparación valvular tricuspídea, sustitución valvular y diversas modalidades de técnicas transcatéter. Con estas consideraciones, presentamos a consideración de ustedes el estado actual de la cirugía en la insuficiencia tricuspídea.


Tricuspid valve disease is considered common and especially in patients with mitral involvement, having been the subject of sustained controversy, both in the selection of the correct therapeutic action and the appropriate moment of its execution. Although the tricuspid valve is affected by stenosis, it is predominantly the seat of an insufficiency-type lesion, which means retrograde passage of blood from the right ventricle (RV) to the right atrium during systole. It can be primary (organic) or secondary (functional), related to right ventricular dilation/dysfunction, annular dilation, traction of its leaflets and pulmonary arterial hypertension. Three- dimensional (3D) echocardiography and cardiac magnetic resonance, by allowing more precise quantification of RV size and systolic function, have allowed earlier therapeutic actions with better results, which include tricuspid valve repair, valve replacement and various modalities of transcatheter techniques. With these considerations, we present for your consideration the current state of surgery in tricuspid regurgitation.

16.
Rev. urug. cardiol ; 39(1): e202, 2024. graf, tab
Article in Spanish | LILACS, BNUY, UY-BNMED | ID: biblio-1565800

ABSTRACT

Introducción: aunque las bioprótesis son menos trombogénicas que las válvulas mecánicas; la trombosis de estas es una entidad cada vez más reconocida como causa de disfunción protésica potencialmente reversible. No está definido el beneficio de la anticoagulación rutinaria versus antiagregación plaquetaria luego de la sustitución valvular aórtica (SVA) por bioprótesis. La anticoagulación precoz podría asociarse a menores gradientes transprotésicos con similar riesgo de complicaciones. Objetivos: el objetivo primario es determinar si existe una diferencia significativa en la variación del gradiente transprotésico medio al año de la SVA entre las dos estrategias de tratamiento antitrombótico. Los objetivos secundarios son la comparación de la variación del gradiente máximo y del área valvular aórtica, y parámetros clínicos que incluyen la Clase Funcional de la New York Heart Association, las tasas de sangrado mayor y menor y la incidencia de eventos embólicos. Este trabajo representa el análisis interino a 3 meses de un proyecto a más largo plazo, y se propone mostrar los resultados preliminares de los puntos finales previamente definidos. Métodos: se presenta el análisis interino de un ensayo randomizado multicéntrico. Todos los pacientes sometidos a SVA por bioprótesis porcinas fueron sucesivamente reclutados en dos centros de cirugía cardíaca desde el 01/01/2019 hasta el 01/09/2019. El grupo anticoagulación recibió warfarina durante los primeros 3 meses y ambos recibieron aspirina a largo plazo. Se realizaron instancias de seguimiento clínicas y ecocardiográficas antes del alta, a los 3 meses y al año. Resultados: se reclutaron 107 pacientes; 46% de ellos fueron randomizados al grupo anticoagulación y 54% al grupo control. No existieron diferencias en las características basales. Tampoco existieron diferencias significativas entre ambos grupos en la variación entre el alta y los 3 meses del área valvular protésica, coeficiente de obstrucción, gradiente máximo ni gradiente medio ni en la clase funcional. En cuanto a las complicaciones, no existieron eventos embólicos y los sangrados no difirieron significativamente entre ambos grupos. Conclusiones: la anticoagulación no modificó la variación de los gradientes transprotésicos a los 3 meses. Asimismo, no produjo mayor incidencia de efectos adversos. Todavía no está dilucidado si la anticoagulación precoz con warfarina luego de la SVA tiene impacto en los resultados a largo plazo.


Introduction: although bioprostheses are less thrombogenic than mechanical valves, bioprosthesis valve thrombosis is an increasingly recognized entity that can cause potentially reversible prosthetic valve dysfunction. There is a lack of consensus whether to use anticoagulation after aortic valve replacement (AVR) or antiplatelet therapy. Our hypothesis is that early anticoagulation is associated with lower transprosthetic gradients with similar risk of complications. Objective: primary objective is to determine if there is a significant difference in the variation of the mean transprosthetic gradient (ΔGm) one year after SVA between the two antithrombotic treatment strategies. Secondary objectives are the comparison of the variation of maximum gradient and aortic valve area, and clinical parameters including NYHA functional class, major and minor bleeding rates, and the incidence of embolic events. This work represents the 3-month interim analysis of a longer-term project, and is intended to show the preliminary results of the previously defined end points. Methods: this is an interim analysis of a multicenter randomized trial. All patients who underwent AVR by porcine bioprostheses were successively recruited in two cardiac surgery centers in Montevideo between 01/01/2019 and 01/09/2019. The anticoagulation group received warfarin for 3 months. Both groups received aspirin. Clinical and echocardiographic follow-up consultations were performed before discharge, at 3 months, and at 1 year. Results: 107 patients were recruited, 46% were randomized to the anticoagulation group and 54% to the control group. There were no differences in baseline characteristics. There were no significant differences between the two groups in the variation between discharge and 3 months of effective orifice area, doppler velocity index, peak gradient and mean gradient. There were also no differences between both groups in functional class. Regarding complications, there were no embolic events and bleeding did not differ significantly. Conclusions: in this study, anticoagulation did not modify the variation of transprosthetic gradients at 3 months. Likewise, it did not produce a higher incidence of adverse effects. It remains unclear whether early anticoagulation with warfarin after AVR has an impact on long-term outcomes.


Introdução: embora as biopróteses sejam menos trombogênicas que as mecânicas, a trombose de biopróteses é uma entidade cada vez mais reconhecida como causa de disfunção protética potencialmente reversível. A anticoagulação de rotina após a substituição da valva aórtica por bioprótese (SVA) não está definida. Nossa hipótese é que a anticoagulação precoce está associada a menores gradientes transprotéticos com risco semelhante de complicações. Objetivo: o objetivo principal é determinar se há uma diferença significativa na variação do gradiente transprotético médio (ΔGm) um ano após SVA entre as duas estratégias de tratamento antitrombótico. Os objetivos secundários são a comparação da variação do gradiente máximo e da área valvar aórtica e parâmetros clínicos, incluindo NYHA CF, taxas de sangramento maior e menor e incidência de eventos embólicos. Este trabalho representa a análise intercalar de 3 meses de um projeto de longo prazo, e pretende mostrar os resultados preliminares dos pontos finais previamente definidos. Métodos: apresenta-se a análise interina de um estudo multicêntrico randomizado. Todos os pacientes submetidos a SVA por biopróteses suínas foram sucessivamente recrutados em dois centros de cirurgia cardíaca em Montevidéu, durante um período de recrutamento de 1/1/2019 a 1/9/2019. O grupo de anticoagulação recebeu warfarina por 3 meses. Ambos os grupos receberam aspirina. Foram realizadas consultas médicas clínicas e ecocardiográficas antes da alta, aos 3 meses e ao 1 ano. Resultados: foram recrutados 107 pacientes, 46% foram randomizados para o grupo anticoagulação e 54% para o grupo controle. Não houve diferenças nas características basais. Não houve diferenças significativas entre os dois grupos da variação entre alta e 3 meses na área valvar, coeficiente de obstrução, gradiente máximo ou gradiente médio. Também não houve diferenças entre os dois grupos na classe funcional. Em relação às complicações, não houve eventos embólicos e sangramentos não diferiram significativamente. Conclusões: neste estudo, a anticoagulação não modificou a variação dos gradientes transprotéticos aos 3 meses. Da mesma forma, não produziu maior incidência de efeitos adversos. Ainda não está claro se a anticoagulação precoce com varfarina após SVA tem impacto nos resultados a longo prazo.


Subject(s)
Humans , Male , Female , Aged , Aged, 80 and over , Warfarin/administration & dosage , Warfarin/adverse effects , Anticoagulants/administration & dosage , Anticoagulants/adverse effects , Bioprosthesis , Heart Valve Prosthesis , Prospective Studies , Multicenter Study , Randomized Controlled Trial , Octogenarians , Hemodynamics/drug effects
17.
Rev. bras. cir. cardiovasc ; Rev. bras. cir. cardiovasc;39(4): e20230088, 2024. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1569615

ABSTRACT

ABSTRACT Introduction: Diabetes mellitus (DM) in patients undergoing cardiac transcatheter or surgical interventions usually is correlated with poor outcomes. Transcatheter aortic valve implantation (TAVI) has been developed as a therapy choice for inoperable, high-, or intermediate-risk surgical patients with severe aortic stenosis (AS). Objective: To evaluate the impact of DM and hemoglobin A1c (HbA1c) on outcomes and survival after TAVI. Methods: Five hundred and fifty-two symptomatic severe AS patients who underwent TAVI, of whom 164 (29.7%) had DM, were included in this retrospective study. Follow-up was performed after 30 days, six months, and annually. Results: The device success and risks of procedural-related complications were similar between patients with and without DM, except for acute kidney injury, which was more frequent in the DM group (2.4% vs. 0%, P=0.021). In-hospital and first-year mortality were similar between the groups (4.9% vs. 3.6%, P=0.490 and 15.0% vs. 11.2%, P=0.282, respectively). There was a statistical difference between HbA1c ≥ 6.5 and HbA1c ≤ 6.49 groups in total mortality (34.4% vs. 15.8%, P<0.001, respectively). The only independent predictors were Society of Thoracic Surgeons score (hazard ratio [HR] 1.28, 95% confidence interval [CI] 1.09-1.51; P=0.003) and HbA1c level ≥ 6.5 (HR 10.78, 95% CI 2.58-21.50; P=0.003) in multivariable logistic regression analysis. Conclusion: In this study, we conclude that DM was not correlated with an increased mortality risk or complication rates after TAVI. Also, it was shown that mortality was higher in patients with HbA1c ≥ 6.5, and it was an independent predictor for long-term mortality.

18.
Rev. bras. cir. cardiovasc ; Rev. bras. cir. cardiovasc;39(4): e20230155, 2024. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1569616

ABSTRACT

ABSTRACT Objective: This study aimed to compare hemodynamic performances and clinical outcomes of patients with small aortic annulus (SAA) who underwent aortic valve replacement by means of sutureless aortic valve replacement (SUAVR) or transcatheter aortic valve implantation (TAVI). Methods: From 2015 to 2020, 622 consecutive patients with SAA underwent either SUAVR or TAVI. Through a 1:1 propensity score matching analysis, two homogeneous groups of 146 patients were formed. Primary endpoint: all cause-death at 36 months. Secondary endpoints: incidence of moderate to severe patient-prosthesis mismatch (PPM) and incidence of major adverse cardiovascular and cerebrovascular events (MACCEs) Results: All-cause death at three years was higher in the TAVI group (SUAVR 12.2% vs. TAVI 21.0%, P=0.058). Perioperatively, comparable hemodynamic performances were recorded in terms of indexed effective orifice area (SUAVR 1.12 ± 0.23 cm2/m2 vs. TAVI 1.17 ± 0.28 cm2/m2, P=0.265), mean transvalvular gradients (SUAVR 12.9 ± 5.3 mmHg vs. TAVI 12.2 ± 6.2 mmHg, P=0.332), and moderate-to-severe PPM (SUAVR 4.1% vs. TAVI 8.9%, P=0.096). TAVI group showed a higher cumulative incidence of MACCEs at 36 months (SUAVR 18.1% vs. TAVI 32.6%, P<0.001). Pacemaker implantation (PMI) and perivalvular leak ≥ 2 were significantly higher in TAVI group and identified as independent predictors of mortality (PMI: hazard ratio [HR] 3.05, 95% confidence interval [CI] 1.34-6.94, P=0.008; PPM: HR 2.72, 95% CI 1.25-5.94, P=0.012). Conclusion: In patients with SAA, SUAVR and TAVI showed comparable hemodynamic performances. Moreover, all-cause death and incidence of MACCEs at follow-up were significantly higher in TAVI group.

19.
Rev. bras. cir. cardiovasc ; Rev. bras. cir. cardiovasc;39(4): e20230438, 2024. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1569617

ABSTRACT

ABSTRACT Objectives: The aims of the present study were to compare the long-term outcomes for ascending aortic dilatation and adverse aortic events after isolated aortic valve replacement between patients with bicuspid aortic valve (BAV) and tricuspid aortic valve ( TAV). Methods: This retrospective study included 310 patients who had undergone isolated aortic valve replacement with an ascending aorta diameter ≤ 45 mm between January 2010 and September 2021. The patients were divided into BAV group (n=90) and TAV group (n=220). The differences in the dilation rate of the ascending aorta and long-term outcomes were analyzed. Results: Overall survival was 89 ± 4% in the BAV group vs. 75 ± 6% in the TAV group at 10 years postoperatively (P=0.007), yet this difference disappeared after adjusting exclusively for age (P=0.343). The mean annual growth rate of the ascending aorta was similar between the two groups during follow-up (0.5 ± 0.6 mm/year vs. 0.4 ± 0.5 mm/year; P=0.498). Ten-year freedom from adverse aortic events was 98.1% in the BAV group vs. 95.0% in the TAV group (P=0.636). Multivariable analysis revealed preoperative ascending aorta diameter to be a significant predictor of adverse aortic events (hazard ratio: 1.76; 95% confidence interval: 1.33 to 2.38; P<0.001). Conclusion: Our study revealed that the long-term survival and the risks of adverse aortic events between BAV and TAV patients were similar after isolated aortic valve replacement. BAV was not a risk factor of adverse aortic events.

20.
Front Cardiovasc Med ; 10: 1228305, 2023.
Article in English | MEDLINE | ID: mdl-38028447

ABSTRACT

Background: Periprocedural myocardial injury (PPMI) frequently occurs after transcatheter aortic valve implantation (TAVI), although its impact on long-term mortality is uncertain. Methods: We performed a pooled analysis of Kaplan-Meier-derived individual patient data to compare survival in patients with and without PPMI after TAVI. Flexible parametric models with B-splines and landmark analyses were used to determine PPMI prognostic value. Subgroup analyses for VARC-2, troponin, and creatine kinase-MB (CK-MB)-defined PPMI were also performed. Results: Eighteen observational studies comprising 10,094 subjects were included. PPMI was associated with lower overall survival (OS) after two years (HR = 1.46, 95% CI 1.30-1.65, p < 0.01). This was also observed when restricting the analysis to overall VARC-2-defined PPMI (HR = 1.23, 95% CI 1.07-1.40, p < 0.01). For VARC-2 PPMI criteria and VARC-2 troponin-only, higher mortality was restricted to the first 2 months after TAVI (HR = 1.64, 95% CI 1.31-2.07, p < 0.01; and HR = 1.32, 95% CI 1.05-1.67, p = 0.02, respectively), while for VARC-2 defined CK-MB-only the increase in mortality was confined to the first 30 days (HR = 7.44, 95% CI 4.76-11.66, p < 0.01). Conclusion: PPMI following TAVI was associated with lower overall survival compared with patients without PPMI. PPMI prognostic impact is restricted to the initial months after the procedure. The analyses were consistent for VARC-2 criteria and for both biomarkers, yet CK-MB was a stronger prognostic marker of mortality than troponin.

SELECTION OF CITATIONS
SEARCH DETAIL