Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 940
Filter
1.
J Proteomics ; 299: 105154, 2024 May 15.
Article in English | MEDLINE | ID: mdl-38471622

ABSTRACT

High-grade serous ovarian cancer (HGSOC) has a high death rate and poor prognosis. The main causes of poor prognosis are asymptomatic early disease, no effective screening method at present, and advanced disease. Changes in cellular metabolism are characteristic of cancer, and plasma metabolome analysis can be used to identify biomarkers. In this study, we used Q Exactive liquid chromatography tandem mass spectrometry (LC-MS/MS, QE) to compare the differentiation between plasma samples (22 HGSOC samples and 22 normal samples). In total, we detected 124 metabolites, and an orthogonal partial least-squares-discriminant analysis (OPLS-DA) model was useful to distinguish HGSOC patients from healthy controls. Choline, 25-hydroxyvitamin D2, and sphingomyelin (d18:0/16:1(9Z) (OH))/SM(d18:0/16:1(9Z) (OH)) showed significantly differential plasma levels in HGSOC patients under the conditions of variable importance in projection (VIP) > 1, p < 0.05 using Student's t-test, and fold change (FC)  ≥ 1.5 or ≤ 0.667. Metabolic pathway analysis can provide valuable information to enhance the understanding of the underlying pathophysiology of HGSOC. In conclusion, the Q Exactive LC/MS/MS method validation-based plasma metabolomics approach may have potential as a convenient screening method for HGSOC and may be a method to monitor tumor recurrence in patients with HGSOC after surgery SIGNIFICANCE: High-grade serous ovarian cancer (HGSOC) has a high death rate and poor prognosis. The main causes of poor prognosis are asymptomatic early disease, no effective screening method at present, and advanced disease. Changes in cellular metabolism are characteristic of cancer, and plasma metabolome analysis can be used to identify biomarkers. In this study, we used Q Exactive liquid chromatography tandem mass spectrometry (LC-MS/MS, QE) to compare the differentiation between plasma samples (20 HGSOC samples and 20 normal samples). In total, we detected 124 metabolites, and an orthogonal partial least-squares-discriminant analysis (OPLS-DA) model was useful to distinguish HGSOC patients from healthy controls. Choline, 25-hydroxyvitamin D2, and sphingomyelin (d18:0/16:1(9Z) (OH))/SM(d18:0/16:1(9Z) (OH)) showed significantly differential plasma levels in HGSOC patients under the conditions of variable importance in projection (VIP) > 1, p < 0.05 using Student's t-test, and fold change (FC) ≥ 1.5 or ≤ 0.667. Metabolic pathway analysis can provide valuable information to enhance the understanding of the underlying pathophysiology of HGSOC. In conclusion, the Q Exactive LC/MS/MS method validation-based plasma metabolomics approach may have potential as a convenient screening method for HGSOC and may be a method to monitor tumor recurrence in patients with HGSOC after surgery.


Subject(s)
Ovarian Neoplasms , Tandem Mass Spectrometry , Humans , Female , Chromatography, Liquid , Tandem Mass Spectrometry/methods , 25-Hydroxyvitamin D 2 , Sphingomyelins , Choline , Neoplasm Recurrence, Local , Early Detection of Cancer , Biomarkers , Metabolomics/methods , Ovarian Neoplasms/diagnosis
2.
J Pharm Biomed Anal ; 239: 115908, 2024 Feb 15.
Article in English | MEDLINE | ID: mdl-38064770

ABSTRACT

Mass spectrometry analysis has been applied in many important diagnostic fields of laboratory medicine. However, there is little literature to guide quality management systems for LC-MS/MS methods. In this study, LC-MS/MS 25-hydroxyvitamin D (25(OH)D) was used as an example to establish internal quality control strategies to ensure the accuracy of clinical vitamin D results. A total of 141 batches of samples were analyzed. Sample internal standard peak area variability, ion pair ratio, and physical examination population data were monitored as quality control strategies for 25(OH)D results. The analytical performance was evaluated by calculated Sigma metrics. Applying our quality control strategies, several abnormal data were monitored in the routine analysis. The daily peak area CV of 25(OH)D fluctuated within a certain range. By selecting P99 CV as the control target, two abnormal batches were found. The ratio of 25(OH)VD3 ion pairs was relatively stable. Among them, batch20230120 had a high CV value, which may be due to the bias caused by the limited number. According to the physical examination data, batch20220913 and batch20220919 exceeded the alarm limit. Sigma level of 25(OH)VD3 in the laboratory was 6.52, which achieved "excellent" performance. In conclusion, we established comprehensive quality control strategies for the determination of 25(OH)D by LC-MS/MS, which has high analytical performance and can provide more accurate reports for the clinic.


Subject(s)
25-Hydroxyvitamin D 2 , Liquid Chromatography-Mass Spectrometry , Chromatography, Liquid/methods , Tandem Mass Spectrometry/methods , Vitamin D , Calcifediol , Quality Control
3.
Article in English | MEDLINE | ID: mdl-38101284

ABSTRACT

Sulfated metabolites of vitamin D have been suggested to be in breastmilk, although current methods to measure sulfated vitamin D compounds in breastmilk by liquid chromatography-tandem mass spectrometry (LC-MS/MS) have not adequately accounted for increased aqueous solubility of these sulfated metabolites. The purpose of this study was to generate a method of LC-MS/MS for measuring vitamin D3-3-sulfate (VitD3-S) and 25-hydroxyvitamin D3-3-sulfate (25OHD3-S) specifically in human breastmilk. The resulting method uses methanol to precipitate protein and solid phase extraction to prepare the samples for LC-MS/MS. The limits of quantification for analytes in solvent were 0.23 ng/mL VitD3-S and 0.2 ng/mL 25OHD3-S. Various experiments observed concentrations ranging 0.53 to 1.7 ng/mL VitD3-S and ≤ 0.29 ng/mL 25OHD3-S. Both analytes were present in aqueous skim milk, demonstrating the enhanced aqueous solubility of these vitamin D sulfates. In conclusion, we describe an effective method for measuring VitD3-S and 25OHD3-S in breastmilk by LC-MS/MS.


Subject(s)
Calcifediol , Tandem Mass Spectrometry , Humans , Chromatography, Liquid/methods , Tandem Mass Spectrometry/methods , Milk, Human , Sulfates , Liquid Chromatography-Mass Spectrometry , Vitamin D , Vitamins , 25-Hydroxyvitamin D 2
4.
Actual. osteol ; 19(3): 181-189, Sept - Dic 2023. ilus, tab
Article in Spanish | LILACS, UNISALUD, BINACIS | ID: biblio-1554586

ABSTRACT

La insuficiencia de vitamina D (VD) en el embarazo se relaciona con una mayor incidencia de cesáreas, preeclampsia y partos prematuros. Objetivo: evaluar si el grado de insuficiencia de VD se asocia a mayor número de cesáreas y evaluar la correlación entre la 25 hidroxivitamina D (25OHD) materna y en sangre del cordón del recién nacido. Las mujeres (n=127) se dividieron según sus niveles de 25OHD (ng/mL):G1:<20 (deficiencia), G2:20-30 (insuficiencia), G3:>30 (suficiencia). Se registraron edad; edad gestacional (EG); índice de masa corporal (IMC); tensión arterial sistólica y diastólica; tipo de parto y la estación del año en que se tomó la muestra. Se determinaron calcemia (ng/mL); 25OHD; parathormona intacta (pg/mL); fosfatasa alcalina ósea (UI/L) y crosslaps (pg/mL). La edad media fue de 26±6 años y la EG de 35,8±2,7 semanas, sin diferencias entre grupos. El porcentaje de cesáreas fue mayor en G1 que en G2 y G3 (31,3%, 21,4% y 25%, respectivamente; p<0,05). El mayor porcentaje de muestras se tomó en primavera (p<0,05). No se observaron diferencias en las demás variables maternas estudiadas. La 25OHD materna correlacionó positivamente con los valores de la sangre de cordón de sus respectivos recién nacidos (r= 0,67; p<0,0001). Independientemente de la época del año y del IMC, se observó que un porcentaje significativo de las mujeres embarazadas estudiadas tenía niveles de 25OHD inferiores a 30 ng/mL. Conclusión: evidenciamos que la deficiencia de VD materna se asoció al número de cesáreas. Asimismo, los niveles séricos de 25OHD en sangre de cordón umbilical correlacionaron significativamente con los maternos. (AU)


Vitamin D (VD) insufficiency in pregnancy is associated with a higher incidence of cesarean section, preeclampsia, and preterm delivery. Objective: to evaluate if the degree of VD insufficiency is associated with the incidence of cesarean section and to determine the correlation between maternal and newborn cord blood 25-hydroxy VS (25OHD). Women (n=127) were divided according to their 25OHD levels (ng/mL): G1:<20 (deficiency), G2:20-30 (insufficiency), G3:>30 (sufficiency). Age; gestational age (GA); body mass index (BMI); systolic and diastolic blood pressure (mmHg); type of delivery and the season of the year in which the sample was taken were recorded. Calcemia (ng/mL); 25OHD; intact parathormone (pg/mL); bone alkaline phosphatase (IU/L) and Crosslaps (pg/mL) levels were determined. Mean age was 26±6 years and GA was 35.8±2.7 weeks with no differences among groups. The % of cesarean sections was higher in G1 than in G2 and G3 (31.3%, 21.4% and 25%; p<0.05). The highest % of samples were taken in spring (p<0.05). No differences were observed in the other maternal variables studied. Maternal serum 25OHD levels correlated positively with those of cord blood from their respective newborns (r=0.67; p<0.0001). Regardless the season of the year and BMI, a high % of the studied pregnant women presented 25OHD levels lower than 30 ng/ml. Conclusion: we found that maternal VD deficiency is associated with the number of cesarean sections. In addition, 25OHD levels in the newborn significantly correlate with maternal serum levels. (AU)


Subject(s)
Humans , Female , Pregnancy , Adult , Young Adult , Vitamin D Deficiency/complications , Pregnancy/statistics & numerical data , Cesarean Section/statistics & numerical data , Pregnancy Trimester, Third , Seasons , Vitamin D , Calcium, Dietary/administration & dosage , 25-Hydroxyvitamin D 2/blood , Incidence , Gestational Age , Fetal Blood , Obstetric Labor, Premature/epidemiology
5.
J Clin Lab Anal ; 37(13-14): e24950, 2023 Jul.
Article in English | MEDLINE | ID: mdl-37526221

ABSTRACT

BACKGROUND: Vitamin D toxicity is rare in pediatric population. Falsely elevated levels of 25-hydroxyvitamin D have been reported as a major challenge with immunoassay methods for quantifying vitamin D metabolites. CASE PRESENTATION AND METHOD: Here, we present two pediatric cases of falsely elevated 25-hydroxyvitamin D that resulted in unnecessary further testing. We also report significant same-day variation in the measurement of 25-hydroxyvitamin D using the Abbott i2000SR immunoassay. Samples were spun twice and their values were confirmed with the gold standard liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for confirmation. CONCLUSION: The addition of a centrifugation step prior to sample testing resolved the variation observed in the measurement of 25-hydroxyvitamin D levels. The patient samples were confirmed with instruments from a different vendor and LC-MS/MS. Re-centrifugation of samples resolved the variation in the 25-hydroxyvitamin D values.


Subject(s)
Tandem Mass Spectrometry , Vitamin D , Humans , Child , Chromatography, Liquid/methods , Tandem Mass Spectrometry/methods , Calcifediol , Vitamins , Immunoassay/methods , 25-Hydroxyvitamin D 2
6.
J Steroid Biochem Mol Biol ; 231: 106328, 2023 07.
Article in English | MEDLINE | ID: mdl-37182753

ABSTRACT

The Vitamin D External Quality Assessment Scheme (DEQAS) distributes serum samples globally, on a quarterly basis, to assess participants' performance of specific methods for 25-hydroxyvitamin D (25OHD) and other vitamin D metabolites. In this review an assessment of the state of the art in the performance of 25OHD methods is presented. This assessment is based on an analysis of data submitted by scheme participants for the 2021/22 distribution cycle, which comprised of four distributions each containing five DEQAS samples. These distributions enabled the assessment of performance across a wide concentration range and included samples containing endogenous 25OHD2. Overall analytical performance continues to improve, but there is still significant method variation and bias in some automated methods. These automated methods continue to be challenged in measuring 25OHD at the extremes of the measuring range and in the presence of 25OHD2. LC-MS/MS methods still show superior performance with regards to bias, but are out-performed by some automated methods in terms of assay variability. Through participating in an accuracy based EQA scheme, such as DEQAS, laboratories are able to assess the accuracy of their methods in comparison to a gold standard reference measurement procedure. It is crucial for all laboratories to be aware of the performance and limitations of their 25OHD assays and to educate their users accordingly in order to ensure reliable assessment of vitamin D status.


Subject(s)
Tandem Mass Spectrometry , Vitamin D , Humans , Chromatography, Liquid , Calcifediol , Vitamins , 25-Hydroxyvitamin D 2
7.
Ann Nutr Metab ; 79(3): 334-342, 2023.
Article in English | MEDLINE | ID: mdl-37253343

ABSTRACT

INTRODUCTION: Vitamin K (VK) as well as vitamin D (VD) plays an important role in osteoporosis. Vitamin K1 (VK1), vitamin K2 (VK2, menaquinone-4 (MK-4), and menaquinone-7 (MK-7)) are significant for the metabolism of skeletal muscle. 25-hydroxyvitamin D2 and 25-hydroxyvitamin D3 (25(OH)D2 and 25(OH)D3) reflect circulating VD levels. More sensitive measurements remain to be developed. In the present study, a new high-performance liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed for the determination of VK1, VK2 (MK-4 and MK-7), as well as 25(OH)D2 and 25(OH)D3 levels in human serum. METHODS: We developed a simple LC-MS/MS method for the determination of VK1, MK-4, MK-7, 25(OH)D2, and 25(OH)D3 levels in human serum and validated the method in a study cohort of 200 patients divided into the premenopausal women group and postmenopausal osteoporosis patient group. RESULTS: The overall precision (coefficient of variation) ranged from 2.66 to 10.11% in the specified working range (0.05-5 ng/mL) for VK1, MK-4, and MK-7. Serum VK1, MK-4, and MK-7 levels in postmenopausal women with osteoporosis were 1.187 ± 0.094 ng/mL, 0.058 ± 0.009 ng/mL, and 0.885 ± 0.064 ng/mL, respectively (mean ± standard deviation). Serum VK1, MK-4, and MK-7 levels in premenopausal women were 1.143 ± 0.103 ng/mL, 0.028 ± 0.003 ng/mL, and 1.553 ± 0.226 ng/mL, respectively. Serum 25(OH)D2 and 25(OH)D3 levels in postmenopausal women with osteoporosis were 0.757 ± 0.056 ng/mL and 11.72 ± 0.632 ng/mL, respectively. Serum 25(OH)D2 and 25(OH)D3 levels in premenopausal were 1.793 ± 0.575 ng/mL and 12.42 ± 1.069 ng/mL, respectively. CONCLUSION: A new LC-MS/MS method for determination of serum VK and VD levels was evaluated and validated. MK-7 in plasma decreased earlier than VD in postmenopausal osteoporosis patients. MK-7 status is significantly associated with osteoporosis and could be considered a predictable biomarker in the diagnosis of osteoporosis in postmenopausal women.


Subject(s)
Osteoporosis, Postmenopausal , Osteoporosis , Humans , Female , Chromatography, Liquid/methods , Vitamin K 1 , Tandem Mass Spectrometry/methods , Vitamin D , Calcifediol , 25-Hydroxyvitamin D 2 , Vitamins
8.
J Nutr ; 153(4): 1253-1264, 2023 04.
Article in English | MEDLINE | ID: mdl-36806449

ABSTRACT

BACKGROUND: Despite an increasing interest in vitamin D status, a reference range of the nutrient has not been fully established. This is partly due to a paucity of standardized measuring systems with high throughput. In addition, the range may vary by populations and may change with modernization of lifestyles. OBJECTIVES: This study aims to calculate the current reference concentration of 25-hydroxyvitamin D (25(OH)D) among healthy people living in an urban area in Japan. METHODS: A newly developed fully automated liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) system was used to measure serum 25(OH)D concentrations. Reproducibility was assessed by measuring standardized samples. Accuracy was validated by comparing with commercially available immunoassays. Then, mass screening was conducted targeting participants who received medical checkups in Tokyo from April 2019 to March 2020, and the reference ranges were calculated. RESULTS: The coefficients of variations of interoperator and interday reproducibility were 4.1%-8.5% and 3.7%-8.0% for 25-hydroxyvitamin D2 (25(OH)D2) and 4.7%-7.0% and 4.0%-6.9% for 25-hydroxyvitamine D3, respectively. The measured total 25(OH)D concentrations correlated well with those measured by immunoassays. In total, 5518 participants were measured for 25(OH)D concentrations, among whom 98% showed inadequate concentrations (<30 ng/mL). The reference ranges of total 25(OH)D for female, male, and total participants were 7-30 ng/mL, 5-27 ng/mL, and 6-29 ng/mL, respectively. After excluding those with abnormal renal and liver function, the range was 6-30 ng/mL. CONCLUSIONS: The high prevalence of vitamin D insufficiency among seemingly healthy population may be attributed to lifestyle characteristics of people living in urban areas of Japan, including spending less time outdoors and lower intake of traditional foods. Longitudinal follow-up and mass screenings targeting different population will help elucidate reasons for discrepancies between official guidelines and the observed concentrations, to which the well-validated measurement system is essential.


Subject(s)
Chromatography, Liquid , East Asian People , Tandem Mass Spectrometry , Vitamin D Deficiency , Vitamin D , Adult , Female , Humans , Male , 25-Hydroxyvitamin D 2 , Calcifediol , Chromatography, Liquid/methods , East Asian People/statistics & numerical data , Reference Values , Reproducibility of Results , Tandem Mass Spectrometry/methods , Vitamin D/blood , Vitamins , Vitamin D Deficiency/blood , Vitamin D Deficiency/diagnosis , Vitamin D Deficiency/epidemiology , Vitamin D Deficiency/etiology , Japan/epidemiology
9.
Eur J Nutr ; 62(3): 1503-1516, 2023 Apr.
Article in English | MEDLINE | ID: mdl-36692589

ABSTRACT

PURPOSE: We aimed to describe the vitamin D status and its distribution in different age groups, sexes, seasons, and provinces of a large Chinese population. METHODS: This study retrospectively analyzed 1,528,685 results of serum 25-hydroxyvitamin D (25(OH)D) in the central laboratory of KingMed Diagnostics. The samples were from the individuals aged 0-119 years old in 30 provinces of China. Serum 25(OH)D was measured by an accurate commercial liquid chromatography-tandem mass spectrometry (LC-MS/MS) method from January 2017 to December 2019. The subjects were stratified by age, sex, the season of blood collection, and the province of residence. RESULTS: The median 25(OH)D concentration was 25.5 ng/mL (interquartile range (IQR) 18.7-32.7 ng/mL) in males and 20.8 ng/mL (IQR 14.4-28.2 ng/mL) in females. Overall, the median 25(OH)D concentration decreased with age in both males and females. Males had a 0.2-2.4 ng/mL higher median 25(OH)D concentration than females in different age groups. Vitamin D deficiency (25(OH)D < 15 ng/mL for the individuals under 14 years old; < 20 ng/mL for the individuals over 14 years old) was found in 21.3% of males and 43.6% of females. Significant seasonal variation of serum 25(OH)D concentrations was repeatedly observed in 3 years, with median concentration higher in summer (25.3 ng/mL (IQR 19.3-31.9 ng/mL)) and lower in winter (18.5 ng/mL (IQR 12.3-26.6 ng/mL)). Vitamin D status varied by province. The median 25(OH)D concentration was the highest in Hainan (31.0 ng/mL (IQR 24.9-39.2 ng/mL)) and the lowest in Qinghai (14.4 ng/mL (IQR 9.6-20.0 ng/mL)). 25(OH)D2 was detected in 12.2% of the results, and no significant seasonal variation was observed. CONCLUSION: In China, vitamin D deficiency is prevalent in the population participating in clinical vitamin D measurement. Age and sex differences in vitamin D levels were observed in our study. Seasonal variation and provincial differences are important aspects of serum vitamin D status. 25(OH)D2 cannot be ignored entirely in clinical measurement practice in China.


Subject(s)
Tandem Mass Spectrometry , Vitamin D Deficiency , Humans , Female , Male , Infant, Newborn , Infant , Child, Preschool , Child , Adolescent , Young Adult , Adult , Middle Aged , Aged , Aged, 80 and over , Seasons , Chromatography, Liquid/methods , Tandem Mass Spectrometry/methods , Retrospective Studies , East Asian People , Vitamin D , Calcifediol , Vitamins , Vitamin D Deficiency/epidemiology , 25-Hydroxyvitamin D 2
11.
Eur J Nutr ; 62(2): 1011-1025, 2023 Mar.
Article in English | MEDLINE | ID: mdl-36350359

ABSTRACT

PURPOSE: To study the intake and sources of vitamin D and determinants of serum 25-hydroxyvitamin D (S-25(OH)D) in Finnish adolescents. METHODS: We studied 265 adolescents (117 girls) aged 15-17 years attending 8-year examinations of the PANIC Study, assessed diet using food records and other lifestyle factors by questionnaires, and analyzed S-25(OH)D by chemiluminescence immunoassay and determinants of S-25(OH)D using multivariate linear regression. RESULTS: Mean (standard deviation) of total vitamin D intake from food and supplements was 19.2 (13.1) µg/d, and that of dietary vitamin D intake was 9.9 (5.4) µg/d. Milk fortified with vitamin D was the main dietary source of vitamin D, providing 45% of daily intake. Altogether, 29% of the adolescents used no vitamin D supplements and 25% did not meet the recommended total vitamin D intake of 10 µg/d. Mean (standard deviation) of S-25(OH)D was 62.0 (18.8) nmol/l, and S-25(OH)D was < 50 nmol/l in 29.5% of the adolescents. Vitamin D intake from supplements was the main determinant of S-25(OH)D (ß = 0.465, p < 0.001), followed by consumption of milk products (ß = 0.251, p < 0.001), consumption of meat products (ß = 0.179, p = 0.002), travels to sunny countries (ß = 0.178, p = 0.002), and average daylight time (ß = 0.162, p = 0.004). CONCLUSION: Most of the adolescents had vitamin D intake at the recommended level, although a fourth did not meet the recommended total vitamin D intake of 10 µg/d and almost a third had S-25(OH)D < 50 nmol/l. More attention should be paid to the sufficient intake of vitamin D in adolescents who do not use vitamin D supplements or fortified milk products. TRIAL REGISTRATION: ClinicalTrials.gov: NCT01803776, registered March 3, 2013.


Subject(s)
Vitamin D Deficiency , Vitamin D , Female , Adolescent , Humans , Finland , Vitamins , Calcifediol , Dietary Supplements , Seasons , 25-Hydroxyvitamin D 2
12.
J Steroid Biochem Mol Biol ; 226: 106206, 2023 02.
Article in English | MEDLINE | ID: mdl-36404469

ABSTRACT

Circulating 25-hydroxyvitamin D [25(OH)D] concentration is used to monitor vitamin D status. Plasma protein binding may influence the 25(OH)D dose-response to vitamin D treatment through a direct relationship between the plasma unbound ("free") fraction and clearance of 25(OH)D. We previously evaluated 25(OH)D3 clearance in relation to kidney function using intravenous administration of deuterium labeled 25(OH)D3. In this follow up study, we determined the free fraction of 25(OH)D3 in plasma (i.e., percent free 25(OH)D3) and the serum concentration and haplotype of vitamin D binding protein in these participants. We hypothesized that the percent free 25(OH)D3 would be positively associated with 25(OH)D3 clearance and would mediate associations between clearance and vitamin D binding protein (GC) haplotypes. Participants were mean (SD) age 64 (10) years and included 42 individuals with normal kidney function (controls), 24 individuals with chronic kidney disease, and 19 individuals with kidney failure on hemodialysis. Free plasma 25(OH)D2 and 25(OH)D3 concentrations were quantified with a new liquid chromatography-tandem mass spectrometry (LC-MS/MS) method. Because there is no reference measurement procedure for free 25(OH)D, we compared the new method with a widely-used predictive equation and a commercial immunoassay. The percent free 25(OH)D3 determined by predictive equation was weakly associated with 25(OH)D3 clearance (R = 0.27; P = 0.01). However, this association was absent when percent free 25(OH)D3 was determined using LC-MS/MS-measured free and total 25(OH)D3 concentrations. Method comparison uncovered a negative bias in immunoassay-measured free 25(OH)D concentrations among participants with kidney failure, so immunoassay results were not used to evaluate the association between percent free 25(OH)D3 and clearance. GC2 haplotype carriage was associated with 25(OH)D3 clearance. Among individuals with 2 relative to no GC2 alleles, clearance was 87 (95% CI: 15-158) mL/d greater. However, in contrast with the literature, GC2 carriage was not significantly related to DBP concentration or the percent free 25(OH)D3 (either predicted or measured). In conclusion, the free fraction of 25(OH)D3 is not strongly associated with 25(OH)D3 clearance but may explain small differences in clearance according to GC haplotype.


Subject(s)
Kidney Diseases , Renal Insufficiency , Humans , Middle Aged , Calcifediol , Vitamin D-Binding Protein/genetics , Chromatography, Liquid/methods , Follow-Up Studies , 25-Hydroxyvitamin D 2 , Tandem Mass Spectrometry/methods , Vitamin D , Vitamins
13.
J Clin Lab Anal ; 36(12): e24756, 2022 Dec.
Article in English | MEDLINE | ID: mdl-36371780

ABSTRACT

OBJECTIVES: The aim of the current study was to establish a reliable candidate reference method for serum 25-hydroxyvitamin D [25(OH)D] measurement and to assess the commutability of multiple control materials among liquid chromatography-tandem mass spectrometry (LC-MS/MS) methods. METHODS: Serum 25-hydroxyvitamin D2 [25(OH)D2] and 25-hydroxyvitamin D3 [25(OH)D3] together with spiked internal standards were extracted with a one-step approach and then analyzed by LC-MS/MS. The commutability assessment for 25(OH)D was conducted according to the Clinical and Laboratory Standards Institute (CLSI) EP14-A3 protocol. 25(OH)D concentrations in 5 levels of unprocessed serum pools, 7 levels of serum pools spiked with 25(OH)D3 or 25(OH)D2, 3 levels of commercial control materials, 2 levels of spiked bovine serum, and 4 levels of external quality assessment (EQA) materials were measured along with 30 single-donor samples using the candidate reference method and two routine LC-MS/MS methods. RESULTS: The candidate reference method could separate 25(OH)D2 and 25(OH)D3 from 14 potential interfering compounds completely within a 9-min analysis time. Good method precision was obtained, and measurement results on certified reference material NIST SRM 972a were within the uncertainty of the certified values. All candidate materials were assessed commutable for LC-MS/MS methods. CONCLUSIONS: The candidate reference method for serum 25(OH)D measurement is precise, accurate, and robust against interferences and can provide an accuracy base for routine methods. The multiple alternative control materials with commutability among LC-MS/MS methods will facilitate the further standardization for serum 25(OH)D measurement.


Subject(s)
25-Hydroxyvitamin D 2 , Tandem Mass Spectrometry , Humans , Chromatography, Liquid/methods , Tandem Mass Spectrometry/methods , Calcifediol , Vitamin D , Reference Standards
14.
Anal Bioanal Chem ; 414(27): 7793-7803, 2022 Nov.
Article in English | MEDLINE | ID: mdl-36109397

ABSTRACT

The majority of circulating 25-hydroxyvitamin D (25(OH)D) is protein bound and perhaps less available than the free fraction of 25(OH)D; therefore, researchers have proposed that the measurement of free 25(OH)D in human serum may be a better indicator of vitamin D health status than total 25(OH)D. The availability of a new enzyme-linked immunosorbent assay (ELISA) for the determination of free 25(OH)D provides a method for direct measurement of the low levels of non-protein bound 25(OH)D. As an initial step towards harmonization of measurements of free 25(OH)D, the ELISA was used to measure free 25(OH)D in three existing Standard Reference Materials (SRMs): SRM 972a Vitamin D Metabolites in Frozen Human Serum, SRM 2973 Vitamin D Metabolites in Frozen Human Serum (High Level), and SRM 1949 Frozen Prenatal Human Serum. Target values for free 25(OH)D in the nine SRM serum pools, obtained by combining the results from two laboratories, ranged from 3.76 ± 0.36 to 10.0 ± 0.58 pg/mL. Of particular significance is the assignment of free 25(OH)D target values to SRM 1949, which consists of four serum pools from non-pregnant female donors of reproductive age and pregnant women in each of the three trimesters and which also has values assigned for vitamin D binding protein, which increases during pregnancy. The availability of target values for free 25(OH)D in these SRMs will allow researchers to validate new analytical methods and to compare their results with other researchers as an initial step towards harmonization of measurements among different studies and laboratories.


Subject(s)
Vitamin D-Binding Protein , Vitamin D , 25-Hydroxyvitamin D 2 , Calcifediol , Enzyme-Linked Immunosorbent Assay , Female , Humans , Pregnancy , Vitamin D/analogs & derivatives , Vitamin D/metabolism , Vitamin D-Binding Protein/metabolism , Vitamins
15.
Methods Mol Biol ; 2546: 539-544, 2022.
Article in English | MEDLINE | ID: mdl-36127620

ABSTRACT

Vitamin D plays an important role not only in bone health but also in many other body functions. Vitamin D deficiency is very common in the general population. Measurement of blood 25-hydroxyvitamin D is a common practice to evaluate vitamin D deficiency. Immunoassays and liquid chromatography tandem mass spectrometry (LC-MS/MS) are the most commonly used methods for the measurement of 25-hydroxyvitamin D. Immunoassays suffer from specificity issues and do not distinguish between 25-hydroxyvitamin D2 and D3. Therefore, LC-MS/MS is a preferred method for quantification of 25-hydroxyvitamin. We describe an LC-MS/MS method, which involves protein precipitation and analysis of the extract using atmospheric pressure chemical ionization and multiple reaction monitoring. 25-hydroxyvitamin D3-d6 is used as an internal standard. The method is linear from 1-100 ng/mL for both 25-hydroxyvitamin D2 and D3 and has imprecision of <10%.


Subject(s)
25-Hydroxyvitamin D 2 , Vitamin D Deficiency , Calcifediol , Chromatography, Liquid/methods , Humans , Tandem Mass Spectrometry/methods , Vitamin D
16.
J Nutr Biochem ; 109: 109123, 2022 11.
Article in English | MEDLINE | ID: mdl-35934272

ABSTRACT

Vitamin D plays an important role in the absorption of calcium and phosphorus, bone metabolism. Various analytical methods are being used to measure the circulating vitamin D levels in the blood. Among all vitamin D metabolites, 25 hydroxyvitamin (25(OH) D) is the most well-known member of the vitamin D family. It is available in two forms, viz. 25 hydroxyvitamin D3 (25(OH)D3) and 25 hydroxyvitamin D2(25(OH)D2). These are stable and available in ample amounts in serum and hence are the most commonly measured during estimation of vitamin D. Although, immunoassay was the most common analytical technique, it could not differentiate between 25(OH) D2 and 25(OH) D3. HPLC is another low-cost technique but lacks sufficient sensitivity for determining trace amounts of 25(OH) D2 and D3. Further, more advanced techniques like liquid chromatography-mass spectrometry have been developed to provide better specificity, higher degree of separation and identification of different forms of vitamin D. However, this technique is not very user friendly. Thus, standardization of these analytical methods in clinical and research laboratories is essential for developing and implementing evidence based clinical guidelines. This will also enable achievement of comparable results via different methods, based on diverse principles. In this manuscript, we have presented a comprehensive overview of the efforts for standardization in vitamin D assessment, along with latest advances in methods used for 25(OH) D2 and 25(OH) D3 analysis. Finally, a summary of clinical trials associated with vitamin D has been presented to discuss all the analytical methods employed for measuring 25(OH) D2 and D3.


Subject(s)
25-Hydroxyvitamin D 2 , Tandem Mass Spectrometry , Calcifediol , Calcium , Phosphorus , Tandem Mass Spectrometry/methods , Vitamin D/analogs & derivatives , Vitamins
17.
BMC Res Notes ; 15(1): 194, 2022 Jun 03.
Article in English | MEDLINE | ID: mdl-35659347

ABSTRACT

OBJECTIVE: We developed an assay to measure the concentration of 25 hydroxyvitamin D2 and D3 in protein extracts derived from stored neonatal dried blood spots. During this study, we postulated that these samples had been contaminated with exogenous vitamin D metabolites because of the addition of bovine serum albumin (BSA) as part of an extraction step undertaken 7 years earlier. The aim of the current study was to develop methods in order to adjust for this contamination. RESULTS: We identified between-plate variations in 25 hydroxyvitamin D2 and D3 concentrations which suggested the presence of three different BSA batches. Based on repeat extraction (without the addition of BSA) and testing of 395 samples, we developed models to correct for the exogenous 25 hydroxyvitamin D2 and D3. The regression models were Diff25OHD3 = - 8.2 + 1.8* Diff25OHD2 for low contamination, Diff25OHD3 = 23.8 + 1.7* Diff25OHD2 for middle contamination, and Diff25OHD3 = 14.3 + 3.0* Diff25OHD2 for high contamination. After these corrections, the three subsamples had comparable distributions within the expected range for both 25 hydroxyvitamin D2 and D3.


Subject(s)
25-Hydroxyvitamin D 2 , Tandem Mass Spectrometry , Calcifediol , Chromatography, Liquid/methods , Humans , Infant, Newborn , Serum Albumin, Bovine , Tandem Mass Spectrometry/methods , Vitamin D
18.
J Nutr Sci Vitaminol (Tokyo) ; 68(3): 181-188, 2022.
Article in English | MEDLINE | ID: mdl-35768249

ABSTRACT

We aimed to assess the difference and agreement between the CL-series Vitamin D Total assay (Mindray), which was a kind of chemiluminescent immunoassay (CLIA) and liquid chromatography-tandem mass spectrometry (LC-MS/MS) in the measurement of serum 25-hydroxyvitamin D [25(OH)D] concentrations in children. We compared the 25(OH)D concentrations of 92 children using the CLIA and LC-MS/MS. Paired samples t-test was used to compare the two groups. Linear regression was used to show the correlation between CLIA and LC-MS/MS. The difference and bias between 2 methods were revealed in Bland-Altman plot. Agreement in classification of deficiency between CLIA and LC-MS/MS was assessed using Cohen's Kappa. p value<0.05 was considered statistically significant. Using Shapiro-Wilk Test to assess whether the data follows a normal distribution. Using 95% children's serum 25(OH)D concentrations by LC-MS/MS as the reference interval. The regression equation was CLIA=1.185×LC-MS/MS-3.328. The fitness adjusted r2 was 0.589. The CLIA showed positive bias compared to LC-MS/MS, p<0.05, bias=(1.94±16.56) ng/mL. Cohen's Kappa=0.53, p<0.001. The agreement of 2 methods in diagnosing "deficiency" was good. According to Shapiro-Wilk Test, the data followed a normal distribution (W=0.99). The reference interval of children's serum 25(OH)D concentrations by LC-MS/MS was 11.35-44.57 ng/mL. In measuring 25(OH)D concentration of children, CLIA represented higher levels than LC-MS/MS. The two methods were consistent in diagnosing vitamin D deficiency. The reference interval of children's serum 25(OH)D concentrations by LC-MS/MS was 11.35-44.57 ng/mL in our area in summer.


Subject(s)
Tandem Mass Spectrometry , Vitamin D , 25-Hydroxyvitamin D 2 , Calcifediol , Child , Chromatography, Liquid/methods , Humans , Immunoassay/methods , Tandem Mass Spectrometry/methods , Vitamin D/analogs & derivatives
19.
Nutrition ; 99-100: 111627, 2022.
Article in English | MEDLINE | ID: mdl-35551015

ABSTRACT

OBJECTIVE: The aim of this study was to investigate the relationship between 25-hydroxyvitamin D3 (25[OH]D3) and ischemic stroke and its potential modifying factors in rural Chinese adults. METHODS: This nested case-control study was drawn from the H-type Hypertension and Stroke Prevention and Control Project, a community-based, prospective, observational study. Plasma 25(OH)D3 was measured by liquid chromatography with tandem quadrupole mass spectrometry. All stroke records came from the Chinese Center for Disease Control and Prevention. Multiple logistic regression models were used to evaluate the association between 25(OH)D3 and risk of ischemic stroke. RESULTS: We included 1079 participants with ischemic stroke and 1079 matched controls. Due to a non-linear relationship, the analyses were stratified by 25(OH)D3. For those with 25(OH)D3 < 20 ng/mL, there was a 15% reduction in the risk of ischemic stroke for each SD increment in 25(OH)D3 (odds ratio, 0.85; 95% confidence interval, 0.73-0.99). Compared with the lowest-tertile group, the risk of ischemic stroke decreased by 39% (odds ratio, 0.61; 95% confidence interval, 0.41-0.89) in the highest-tertile group. Furthermore, two effect modifiers were identified: diabetes and homocysteine level. Although participants with 25(OH)D3 ≥ 20 ng/mL had the lowest risk of ischemic stroke overall, there was no dose-response association within that range. CONCLUSIONS: An inverse dose-response association between 25(OH)D3 and incident risk of ischemic stroke in rural Chinese adults was only observed in those with 25(OH)D3 < 20 ng/mL, along with two effect modifiers. Higher levels of 25(OH)D3 did not confer additional benefit.


Subject(s)
Calcifediol , Ischemic Stroke , 25-Hydroxyvitamin D 2 , Adult , Case-Control Studies , China/epidemiology , Humans , Prospective Studies , Vitamin D/analogs & derivatives
20.
PLoS One ; 17(5): e0268038, 2022.
Article in English | MEDLINE | ID: mdl-35503795

ABSTRACT

OBJECTIVES: Studies investigating the association between vitamin D and severity of COVID-19 have mixed results perhaps due to immunoassay assessment of total 25-hydroxyvitamin D (tD) (the sum of 25-hydroxyvitamin-D2 [25-OH-D2] and 25-hydroxyvitamin-D3 [25-OH-D3]). Liquid chromatography tandem mass spectrometry (LC-MS/MS) has high analytical specificity and sensitivity for 25-OH-D2 and 25-OH-D3, and thus enables a more accurate assessment of impact on COVID-19 outcomes. METHODS: We established reference intervals for 25-OH-D3 and tD using LC-MS/MS. 25-OH-D2, 25-OH-D3 and tD were quantitated for 88 COVID-19 positive and 122 COVID-19 negative specimens. Chi-square or Fisher's exact tests were used to test associations in binary variables. T-Tests or Wilcoxon rank sum tests were used for continuous variables. Cox proportional hazards were used to test associations between 25-OH-D3 or tD levels and length of stay (LOS). For mortality and ventilation, logistic regression models were used. RESULTS: COVID-19 patients with deficient (<20 ng/mL) levels of 25-OH-D3 had significantly longer LOS by 15.3 days. COVID-19 P patients with deficient (<20 ng/mL) and insufficient (<30 ng/mL) of tD had significantly longer LOS by 12.1 and 8.2 days, respectively. Patients with insufficient levels of tD had significantly longer LOS by 13.7 days. COVID-19 patients with deficient serum 25-OH-D3 levels had significantly increased risk-adjusted odds of in-hospital mortality (OR [95% CI]: 5.29 [1.53-18.24]); those with insufficient 25-OH-D3 had significantly increased risk for requiring ventilation during hospitalization was found at LCMS insufficient cutoff (OR [95% CI]: 2.75 [1.10-6.90]). CONCLUSIONS: There is an inverse relationship of 25-hydroxyvitamin D levels and hospital LOS for COVID-19 patients. Vitamin D status is a predictor for severity of outcomes. LCMS results are useful for assessing the odds of mortality and the need for ventilation during hospitalization.


Subject(s)
COVID-19 , Tandem Mass Spectrometry , 25-Hydroxyvitamin D 2 , Calcifediol , Chromatography, Liquid/methods , Humans , Tandem Mass Spectrometry/methods , Vitamin D/analogs & derivatives , Vitamins
SELECTION OF CITATIONS
SEARCH DETAIL
...