1.
Circ Arrhythm Electrophysiol ; 17(5): e012513, 2024 May.
Article in English | MEDLINE | ID: mdl-38690657

ABSTRACT

BACKGROUND: The anatomy of myocardial fibers around the right cardiac veins (RCVs) and their roles in accessory pathways (APs) are rarely reported. METHODS: Six RCV-APs were identified from 566 patients with right-sided APs. Mapping of retrograde atrial activation was performed using CARTO 3 system under orthodromic tachycardia or right ventricular pacing. Venography of RCVs was acquired at the earliest retrograde atrial activation. RESULTS: Patients enrolled had a median age of 30 (11-51) years, 5 of them were male. Venography of RCVs could be classified into 3 distinct patterns based on the identified ventricular branches, right marginal vein only (type I; n=3), both right marginal vein and anterior cardiac veins (type II; n=2), and anterior cardiac vein only (type III; n=1). Patients with type I venography had rS QRS pattern in lead V1, negative delta wave in lead III and negative or isoelectric delta wave in lead aVF. However, patients with type II and III venography had QS QRS patterns in lead V1 and variable patterns of delta wave in inferior leads. Earliest retrograde atrial activation was found at a median of 16.75 (14.60-20.00) mm away from the tricuspid annulus, all with A larger than V. At the earliest retrograde atrial activation, far-field ventricular electrogram was found 30 ms later than QRS onset in 1 patient under sinus rhythm. AP conduction was eliminated by mechanical pressure in 2 and by radiofrequency ablation in 4 at the ostium of the veins colocalizing with the earliest retrograde activation of the right atrium. No recurrence was observed during 36 (10-60) months follow-up. CONCLUSIONS: The RCV-AP is a rare form of right-sided APs characterized by atrial insertions distant from the annulus. ECG-speculated ventricular insertion sites conformed to the location of identified RCVs.


Subject(s)
Accessory Atrioventricular Bundle , Catheter Ablation , Phlebography , Humans , Male , Adult , Female , Middle Aged , Accessory Atrioventricular Bundle/physiopathology , Accessory Atrioventricular Bundle/surgery , Adolescent , Young Adult , Child , Electrophysiologic Techniques, Cardiac , Coronary Vessels/physiopathology , Coronary Vessels/diagnostic imaging , Action Potentials , Heart Rate , Cardiac Pacing, Artificial
4.
Herzschrittmacherther Elektrophysiol ; 35(Suppl 1): 118-126, 2024 Mar.
Article in German | MEDLINE | ID: mdl-38427036

ABSTRACT

In 1930, Wolff, Parkinson and White described the syndrome that bears their names. The mechanisms of supraventricular tachycardias were analyzed by brilliant electrocardiography interpretation by Pick and Langendorf. Wellens and Durrer using electrophysiologic studies analyzed the tachycardia mechanism invasively. In Germany the group by Seipel and Breithardt as well as Neuss and Schlepper studied the tachycardia mechanisms and response to antiarrhythmic drugs invasively by electrophysiological studies. Following the first successful interruption of an accessory pathway by Sealy in 1967, surgeons and electrophysiologists cooperated in Germany. Two centers, Hannover and Düsseldorf were established. Direct current (DC) ablation of accessory pathways was introduced by Morady and Scheinman. Because of side effects induced by barotrauma of DC, alternative strategies were studied. In 1987, radiofrequency ablation was introduced and thereafter established as curative therapy of accessory pathways in all locations.


Subject(s)
Accessory Atrioventricular Bundle , Catheter Ablation , Pre-Excitation Syndromes , Tachycardia, Supraventricular , Wolff-Parkinson-White Syndrome , Humans , Wolff-Parkinson-White Syndrome/diagnosis , Wolff-Parkinson-White Syndrome/surgery , Pre-Excitation Syndromes/diagnosis , Pre-Excitation Syndromes/therapy , Tachycardia, Supraventricular/surgery , Tachycardia/surgery , Accessory Atrioventricular Bundle/diagnosis , Accessory Atrioventricular Bundle/surgery , Electrocardiography
5.
Clin Cardiol ; 47(1): e24180, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37889106

ABSTRACT

BACKGROUND: Radiofrequency (RF) catheter ablation of para-Hisian accessory pathways (APs) can be challenging due to proximity to the conduction system. METHODS: A total of 30 consecutive patients with para-Hisian AP were enrolled for ablation in three centers, 12 (40%) of whom had previously failed attempted ablation from the inferior vena cava (IVC) approach. Ablation was preferentially performed using a superior approach from the superior vena cava (SVC) in all patients. RESULTS: The para-Hisian AP was eliminated from the SVC approach in 28 of 30 (93.3%) patients. In the remaining two patients, additional ablation from IVC was required to successfully eliminate the AP. There were two patients experienced reversible complete atrial-ventricular block and PR prolongation during the first RF application. Long-term freedom from recurrent arrhythmia was achieved in 29 (96.7%) patients over a mean follow-up duration of 15.6 ± 4.6 months. CONCLUSION: Catheter ablation of para-Hisian AP from above using a direct SVC approach is both safe and effective, and should be considered especially in patients who have failed conventional ablation attempts from IVC approach.


Subject(s)
Accessory Atrioventricular Bundle , Catheter Ablation , Humans , Vena Cava, Superior/diagnostic imaging , Vena Cava, Superior/surgery , Treatment Outcome , Bundle of His , Heart Conduction System/surgery , Accessory Atrioventricular Bundle/surgery , Catheter Ablation/adverse effects
6.
Ann Noninvasive Electrocardiol ; 29(1): e13100, 2024 01.
Article in English | MEDLINE | ID: mdl-38115789

ABSTRACT

BACKGROUND: Posteroseptal accessory pathways (APs) associated with coronary sinus (CS) diverticulum present a rare and challenge for ablation. This study aimed to compare the safety and efficacy of conventional approach and three-dimensional (3D) mapping system in the catheter ablation. METHODS AND RESULTS: This was a retrospective study of all patients (from January 2013 to July 2022) who underwent catheter ablation of posteroseptal AP associated with CS diverticula in our center. Patients who underwent catheter ablation using the traditional fluoroscopy method were included in the conventional method group (n = 13). Patients who underwent catheter ablation using the 3D mapping method were included in the 3D mapping group (n = 11). Clinical characteristics, ablation procedure, and outcomes were recorded and analyzed between the two groups. Out of 669 patients with posteroseptal APs, 24 of them (3.6%) were associated with CS diverticula. All patients in both groups successfully completed the electrophysiological study. In the conventional method group, two patients experienced complications (one patient with pericardial effusion and the other patient with femoral arterial hematoma), and two patients had recurrence. However, no patients suffered from complications or recurrence during follow-up. The procedure time and fluoroscopy time in the conventional method group were significantly longer than those in the 3D mapping method group. CONCLUSIONS: The utilization of 3D mapping led to reduced fluoroscopy time, shorter procedure duration, enhanced acute success rates, and decreased incidence of complications.


Subject(s)
Accessory Atrioventricular Bundle , Catheter Ablation , Coronary Sinus , Diverticulum , Heart Defects, Congenital , Humans , Coronary Sinus/diagnostic imaging , Coronary Sinus/surgery , Retrospective Studies , Electrocardiography/methods , Accessory Atrioventricular Bundle/diagnostic imaging , Accessory Atrioventricular Bundle/surgery , Heart Defects, Congenital/surgery , Catheter Ablation/methods , Diverticulum/complications , Diverticulum/diagnostic imaging , Diverticulum/surgery
7.
J Cardiovasc Electrophysiol ; 34(12): 2617-2620, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37964504

ABSTRACT

INTRODUCTION: Acquired Wolff-Parkinson-White (WPW) syndrome can occur after congenital heart disease (CHD) surgery. METHODS AND RESULTS: A 27-year-old male with Ebstein's anomaly and manifest WPW syndrome received catheter ablation twice. The first electrophysiology study (EPS) induced orthodromic atrioventricular reentrant tachycardia and successfully eliminated the posteroseptal accessory pathway (AP). Six months after the Cone procedure, the patient suffered from palpitation. The second EPS was performed and abolished the right lateral AP. CONCLUSION: The appearance of a new AP after the reconstruction of CHD is a rare finding and should raise suspicion of an acquired AP connection.


Subject(s)
Accessory Atrioventricular Bundle , Catheter Ablation , Ebstein Anomaly , Heart Defects, Congenital , Tachycardia, Supraventricular , Wolff-Parkinson-White Syndrome , Male , Humans , Adult , Accessory Atrioventricular Bundle/surgery , Wolff-Parkinson-White Syndrome/diagnosis , Wolff-Parkinson-White Syndrome/surgery , Arrhythmias, Cardiac/surgery , Heart Defects, Congenital/surgery , Catheter Ablation/adverse effects , Catheter Ablation/methods , Electrocardiography
9.
Herzschrittmacherther Elektrophysiol ; 34(4): 278-285, 2023 Dec.
Article in German | MEDLINE | ID: mdl-37861731

ABSTRACT

Atrioventricular nodal reentrant tachycardia (AVNRT) and atrioventricular reentrant tachycardia in patients with accessory pathways (AP) are common supraventricular tachycardias. High long-term efficacy of about 97% (AVNRT) and 92% (AP) has been observed in children and adults. The risk of occurring atrioventricular block is low (0.4-0.8% during AVNRT, 0.1-0.2% for AP). Catheter ablation shows a lower efficacy of 87-93% and elevated atrioventricular block risk up to 10% in patient groups with complex congenital heart disease. Nonsynchronized ventricular activation during preexcitation or permanent reentrant tachycardias can induce heart failure, and remission of left ventricular function can be expected in > 90% after successful catheter ablation. Therefore, catheter ablation is the long-term therapy of choice for AVNRT and AP with high efficacy and safety for most patient populations.


Subject(s)
Accessory Atrioventricular Bundle , Atrioventricular Block , Catheter Ablation , Tachycardia, Atrioventricular Nodal Reentry , Tachycardia, Supraventricular , Adult , Child , Humans , Tachycardia, Atrioventricular Nodal Reentry/diagnosis , Tachycardia, Atrioventricular Nodal Reentry/surgery , Accessory Atrioventricular Bundle/surgery , Catheter Ablation/methods , Electrocardiography
10.
J Interv Card Electrophysiol ; 66(9): 2153-2164, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37864653

ABSTRACT

BACKGROUND: Intracoronary sinus ablations have been performed for various arrhythmical substrates. The aim of this study is to report our experience on pediatric patients of the safety and efficacy of ablations in the coronary sinus. METHODS: This is a retrospective study of all patients who underwent ablations in the coronary sinus from October 2013 to October 2021 at a single center. Clinical presentation, type of arrhythmia causing tachycardia, ablation procedure, and outcome were recorded. RESULTS: A total of 27 patients were included in the study. Nineteen (69%) of those followed up received a diagnosis of Wolff-Parkinson-White syndrome (WPW), 4 (15%) were cases of supraventricular tachycardia with concealed accessory pathway (AP), 2 (8%) were cases of focal atrial tachycardia, and 2 (8%) were cases of permanent junctional reciprocating tachycardia. Negative delta wave was noteworthy especially in lead II in 11/19 (58%) cases and coronary sinus diverticulum was detected in the WPW cases. Of those with manifest AP (19 cases), 15 (79%) had a high-risk AP and the AP in all WPW cases was adenosine unresponsive. Radiofrequency (RF) catheter ablation was performed in 25/27 (93%) cases during the procedure, and 16/25 (64%) of these were irrigated RF catheters. No complications were observed in the follow-up, including coronary artery injury. CONCLUSIONS: Catheter ablation of supraventricular tachyarrhythmias can be accomplished effectively and potentially safely within the coronary sinus. Coronary sinus diverticula should be suspected in patients with manifest posteroseptal APs who have a previous failed ablation and typical electrocardiographic signs.


Subject(s)
Accessory Atrioventricular Bundle , Catheter Ablation , Coronary Sinus , Tachycardia, Supraventricular , Wolff-Parkinson-White Syndrome , Humans , Child , Coronary Sinus/diagnostic imaging , Coronary Sinus/surgery , Retrospective Studies , Wolff-Parkinson-White Syndrome/surgery , Accessory Atrioventricular Bundle/surgery , Tachycardia, Supraventricular/surgery , Tachycardia/surgery , Electrocardiography
11.
J Cardiovasc Electrophysiol ; 34(12): 2573-2580, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37890039

ABSTRACT

INTRODUCTION: Accessory pathway (AP) ablation is a straightforward approach with high success rates, but the fluoroscopy time (FT) is significantly longer in conventional technique. Electroanatomical mapping systems (EMS), reduce the FT, but anatomical and activation mapping may prolong the procedure time (PT). The fluoroscopy integration module (FIM) uses prerecorded fluoroscopy images and allows ablation similar to conventional technique without creating an anatomical map. In this study, we investigated the effects of combining the FIM with traditional technique on PT, success, and radiation exposure. METHODS: A total of 131 patients who had undergone AP ablation were included in our study. In 37 patients, right and left anterior oblique (RAO-LAO) images were acquired after catheter placement and integrated with the FIM. The ablation procedure was then similar to the conventional technique, but without the use of fluoroscopy. For the purpose of acceleration, anatomical and activation maps have not been created. Contact-force catheters were not used. 94 patients underwent conventional ablation using fluoroscopy only. RESULTS: FIM into AP ablation procedures led to a significant reduction in radiation exposure, lowering FT from 7.4 to 2.8 min (p < .001) and dose-area product from 12.47 to 5.8 µGym² (p < .001). While the FIM group experienced a reasonable longer PT (69 vs. 50 min p < .001). FIM reduces FT regardless of operator experience and location of APs CONCLUSION: Combining FIM integration with conventional AP ablation offers reduced radiation exposure without compromising success rates and complication.


Subject(s)
Accessory Atrioventricular Bundle , Catheter Ablation , Humans , Catheter Ablation/adverse effects , Catheter Ablation/methods , Radiation Dosage , Accessory Atrioventricular Bundle/diagnostic imaging , Accessory Atrioventricular Bundle/surgery , Time Factors , Fluoroscopy/methods , Treatment Outcome
12.
J Cardiovasc Electrophysiol ; 34(11): 2406-2409, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37855612

ABSTRACT

INTRODUCTION: This study describes a rare case of concealed epicardial accessory pathway (AP) successfully ablated using ethanol infusion (EI) through a variant vessel connecting the right atrium (RA) and the right ventricle (RV) surface. METHODS AND RESULTS: A 58-year-old male referred to our hospital for prior failed AP ablation. Cardiac-enhanced computerized tomography scan showed there was a variant vessel at the tip of right atrial appendage and a pulmonary artery (PA)-RA fistula at the roof of RA. The earliest activation was present at the site of the PA-RA fistula. A selective angiography showed that a small branch of the variant vessel covered the earliest excitation site of the AP. EI into this branch successfully repressed the AP without any recurrences within a follow-up period of 3 months. CONCLUSION: Endocardial ablation is challenging for epicardial APs related to cardiac structural variations. If small vascular branches near the earliest activation site can be found, EI can successfully ablate these types of epicardial APs.


Subject(s)
Accessory Atrioventricular Bundle , Catheter Ablation , Fistula , Male , Humans , Middle Aged , Catheter Ablation/methods , Accessory Atrioventricular Bundle/diagnostic imaging , Accessory Atrioventricular Bundle/surgery , Bundle of His , Heart Atria , Electrocardiography
13.
J Cardiovasc Electrophysiol ; 34(11): 2398-2402, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37727933

ABSTRACT

INTRODUCTION: Herein, we present a rare case of the successful ablation of an accessory pathway (AP) involving the Marshall Bundle (MB) and coronary sinus musculature (CSM) in a 40-year-old man with Wolff-Parkinson-White syndrome. METHODS AND RESULTS: An orthodromic reciprocating tachycardia (ORT) was inducible with the earliest atrial activation site located at the posterolateral mitral annulus. The local conduction and the cycle length of ORT was prolonged by peri-mitral ablation; however, it failed to block the AP. The atrial insertion of the AP was identified by remapping during ORT at the left atrial ridge, which was away from the mitral annulus, where ablation was successful. Together with the electrophysiological findings in CSM potentials, we conclude that the epicardial MB-CSM connection functioned as the AP in this patient. CONCLUSION: The novel variant form of AP comprised of MB and CSM should be noted. The atrial insertion of the MB may be the target of catheter ablation.


Subject(s)
Accessory Atrioventricular Bundle , Catheter Ablation , Coronary Sinus , Tachycardia, Reciprocating , Wolff-Parkinson-White Syndrome , Male , Humans , Adult , Coronary Sinus/diagnostic imaging , Coronary Sinus/surgery , Accessory Atrioventricular Bundle/surgery , Tachycardia, Reciprocating/diagnosis , Tachycardia, Reciprocating/surgery , Bundle of His , Wolff-Parkinson-White Syndrome/diagnosis , Wolff-Parkinson-White Syndrome/surgery , Electrocardiography
14.
Pacing Clin Electrophysiol ; 46(9): 1049-1055, 2023 09.
Article in English | MEDLINE | ID: mdl-37527153

ABSTRACT

BACKGROUND: Intermittent ventricular pre-excitation was considered a low-risk marker for sudden death. However, to date, some studies do not exclude the existence of accessory pathways (APs) with high-risk intermittent antegrade conductive properties. According to current European Guidelines, high-risk features of APs are antegrade pathway conduction ≤250 ms in baseline or during the adrenergic stimulus, inducibility of atrioventricular reciprocating tachycardias (AVRT), inducibility of pre-excited atrial fibrillation (AF), and presence of multiple APs. For all of these transcatheter ablation is recommended. The aim of our study was to evaluate the existence of differences in risk characteristics between patients with intermittent pre-excitation (IPX) and those with persistent pre-excitation (PPX), from a sample of adults with ventricular pre-excitation and symptoms like palpitations. METHODS: 293 adults [IPX: 51 (17.4%); PPX: 242 (82.6%)] underwent electrophysiological study and then catheter ablation of their APs if arrhythmia inducibility (AVRT/AF) was noted, or, conversely, if it was appreciated a fast AP antegrade conduction, in baseline or during intravenous isoproterenol infusion, or if multiple APs were detected. RESULTS: There were no statistically significant differences in demographic characteristics (age and gender), AVRT/AF inducibility, antegrade conductive properties, the prevalence of multiple APs, and APs locations between IPX and PPX patients. CONCLUSIONS: In our study, patients with IPX did not show significant differences in clinical and electrophysiological features versus PPX patients.


Subject(s)
Accessory Atrioventricular Bundle , Atrial Fibrillation , Catheter Ablation , Pre-Excitation Syndromes , Wolff-Parkinson-White Syndrome , Humans , Adult , Accessory Atrioventricular Bundle/surgery , Atrial Fibrillation/surgery , Risk Factors , Electrocardiography
15.
Pacing Clin Electrophysiol ; 46(8): 875-881, 2023 08.
Article in English | MEDLINE | ID: mdl-37483154

ABSTRACT

AIM: The implementation of 3D mapping systems plays an important role in interventional electrophysiology (EP) in recent years. The aim of the present study was to evaluate use of 3D mapping systems regarding fluoroscopy and procedure duration. METHOD: In the "Go for Zero Fluoroscopy" project 25 European centers provided data of consecutive EP procedures. Data on use of 3D mapping systems as well as utilization of contact force catheters and multipolar mapping catheters were associated with fluoroscopy time, dose area product (DAP), and procedure duration. RESULT: A 3D mapping system was used in 966 (54%) cases. Use of 3D mapping for atrioventricular nodal reentry tachycardia (AVNRT) was associated with reduced fluoroscopy time (p < 0.001), DAP (p = 0.04) but increased procedure time (p = 0.029). Moreover, fluoroscopy time (p < 0.001) and DAP (p = 0.005) were significantly lower in the 3D mapping group in ablation of typical atrial flutter. However, the procedure time (p < 0.001) increased. Use of 3D mapping in the ablation of accessory pathway (AP) was associated with reduced fluoroscopy time (p < 0.001) and DAP (p < 0.001) with no significant increase in procedure time (p = 0.066). In the case of atrial fibrillation, a 3D mapping system was used in 485 patients (75.8%). Additional use of a contact force catheter was associated with lower fluoroscopy time (p < 0.001) and DAP (p < 0.001). Use of a multipolar mapping catheter was associated with lower fluoroscopy time (p = 0.002). The implementation of 3D mapping systems in the ablation of ventricular tachycardias resulted in a significant increase in the procedure time (p = 0.001) without significant differences regarding the DAP (p = 0.773) and fluoroscopy time (p = 0.249). CONCLUSION: Use of 3D mapping systems in ablation of supraventricular tachycardias is associated with lower radiation exposure. Nevertheless, the procedure time often increases, except in the case of ablation for AP. Use of contact force catheters and multipolar mapping catheters is associated with yet lower radiation exposure values. Prospective randomized studies are needed to further elucidate potential benefit of these technological tools.


Subject(s)
Accessory Atrioventricular Bundle , Atrial Fibrillation , Catheter Ablation , Humans , Prospective Studies , Treatment Outcome , Atrial Fibrillation/surgery , Accessory Atrioventricular Bundle/surgery , Cardiac Electrophysiology , Fluoroscopy/methods , Catheter Ablation/methods
16.
J Cardiovasc Electrophysiol ; 34(9): 1828-1834, 2023 09.
Article in English | MEDLINE | ID: mdl-37449445

ABSTRACT

INTRODUCTION: Accessory atrioventricular pathways (APs) may mediate atrioventricular reciprocating tachycardia and, in some cases, have the potential to conduct atrial tachycardia rapidly, which can be life threatening. While catheter ablation can be curative, ablation of right free wall APs is associated with a high rate of recurrence, likely secondary to reduced catheter stability along the right free wall atrioventricular groove. We sought to identify characteristics associated with a lower rate of recurrence and hypothesized ablation lesions placed on the ventricular side of the atrioventricular groove using a retroflexed catheter approach would decrease rates of recurrence. METHODS AND RESULTS: Retrospective chart review of patients who underwent catheter ablation of a right free wall AP from January 1, 2008 through June 1, 2021 with >2 months follow up. Cox proportional hazards regression was used to identify relationships between predictor variables and AP recurrence. We identified 95 patients who underwent ablation of 98 right free wall APs. Median age was 13.1 years and median weight at ablation was 52.3 kg. Overall, 23/98 (23%) APs recurred. Use of a retroflexed catheter course approaching the atrioventricular groove from the ventricular aspect was associated with reduced risk of AP recurrence with (univariable hazard ratio of 0.10 [95% confidence interval: 0.01-0.78]), which remained significant in multiple two variable Cox proportional hazards models. CONCLUSION: Use of a retroflexed catheter course is associated with a reduced likelihood of AP recurrence. This approach results in improved catheter stability and should be considered for ablation of right free wall APs.


Subject(s)
Accessory Atrioventricular Bundle , Catheter Ablation , Ventricular Septum , Wolff-Parkinson-White Syndrome , Humans , Adolescent , Retrospective Studies , Bundle of His , Accessory Atrioventricular Bundle/surgery , Catheters , Catheter Ablation/adverse effects
18.
Pacing Clin Electrophysiol ; 46(8): 882-889, 2023 08.
Article in English | MEDLINE | ID: mdl-37493225

ABSTRACT

BACKGROUND: Open-window mapping (OWM) is a novel automated mapping method for catheter ablation of an accessory pathway (AP), in which the local signal is annotated with window-of-interest parameters to analyze both atrial and ventricular signals. This study aimed to determine the utility of OWM in visualizing the location and width of APs in patients with Wolff-Parkinson-White syndrome. METHODS: This two-center study enrolled 30 patients (20 males; mean age: 56 years, interquartile range [IQR]: 22-69 years) who underwent high-density OWM with the extended early-meets-late (EEML) algorithm using a 20-electrode, 5-spline catheter (PENTARAY, Biosense Webster). The lower threshold of the EEML was set to adjust the EEML gap to match the propagation mapping, and broad APs were defined as an EEML gap > 1 cm. RESULTS: The median mapping points, mapping time, and lower threshold of the EEML were 2482 (IQR: 1755-4000) points, 23 (IQR: 15-30) min, and 23 (IQR: 18-25), respectively. All 30 APs (24 in the mitral annulus and 6 in the tricuspid annulus) were successfully eliminated. Of these APs, 21 (70%) were eliminated by the first radio frequency (RF) application. OWM revealed broad APs in 11 patients (37%), in four of whom (36%) the first RF application achieved a loss of AP conduction (vs. 90% of patients without broad APs; p = .004). CONCLUSION: OWM facilitates the visualization of the location and width of APs, which may be particularly useful for predicting whether multiple RF applications are required for broad APs.


Subject(s)
Accessory Atrioventricular Bundle , Catheter Ablation , Wolff-Parkinson-White Syndrome , Male , Humans , Young Adult , Adult , Middle Aged , Aged , Wolff-Parkinson-White Syndrome/surgery , Accessory Atrioventricular Bundle/surgery , Catheter Ablation/methods , Heart Ventricles , Radio Waves , Electrocardiography
20.
Eur J Pediatr ; 182(8): 3659-3669, 2023 Aug.
Article in English | MEDLINE | ID: mdl-37261549

ABSTRACT

Wolf-Parkinson-White (WPW) accessory pathway (AP) may be associated with reentry supraventricular tachycardia (SVT) in addition to ventricular dyssynchrony and cardiac dysfunction. Electrophysiological studies (EPS) are the gold standard for the localization of the AP; however, 2D speckle-tracking echocardiography (2D-STE) may help in the localization of the AP noninvasively. Our study aims to evaluate the capability of 2D-STE for AP localization and the identification of AP-related contractile abnormalities and dyssynchrony in pediatric patients with WPW syndrome. This prospective multicenter cohort study involved 18 pediatric patients with ventricular preexcitation from January 2021 to January 2023. Tissue Doppler imaging (TDI), conventional echocardiography, and 2D-STE were done. Myocardial velocities, myocardial performance index (MPI), the global and segmental longitudinal strain of the left ventricle (LV), and time-to-peak longitudinal strain (TPLS) were measured before and after ablation. The longitudinal strain of the LV segments supplied by the AP, or the nearby segments close to the AP, was significantly impaired and improved after ablation (P = 0.0001). The abnormal strain pattern in the affected segments could predict the location of the AP. The TPLS of the affected segments significantly increased after ablation (P = 0.0001), denoting improved dyssynchrony. The ejection time and the LV MPI measured at the basal septum improved significantly after ablation. CONCLUSIONS: 2D STE may be used for noninvasive localization of the AP and to evaluate cardiac function and dyssynchrony in patients with WPW. Further research on more patients is necessary to validate this method for AP localization. WHAT IS KNOWN: • Accessory pathways (AP) associated with the Wolf-Parkinson-White (WPW) syndrome have been linked to supraventricular tachycardia (SVT). Even without SVT, WPW can cause left ventricular dyssynchrony, contractile dysfunction, and cardiomyopathy. • Electrophysiology study is the gold standard for the localization of the AP in WPW syndrome. WHAT IS NEW: • The combination of 2D-speckle-tracking echocardiography (2D-STE) and the modified Arruda algorithm can precisely localize the AP associated with WPW syndrome. • 2D-STE can potentially assess cardiac function and dyssynchrony related to WPW syndrome. Additionally, 2D-STE can be utilized to evaluate the effectiveness of ablation in restoring cardiac function and dyssynchrony.


Subject(s)
Accessory Atrioventricular Bundle , Tachycardia, Supraventricular , Ventricular Dysfunction, Left , Wolff-Parkinson-White Syndrome , Wolves , Animals , Humans , Wolff-Parkinson-White Syndrome/diagnosis , Wolff-Parkinson-White Syndrome/diagnostic imaging , Prospective Studies , Cohort Studies , Ventricular Dysfunction, Left/diagnostic imaging , Ventricular Dysfunction, Left/etiology , Accessory Atrioventricular Bundle/diagnostic imaging , Accessory Atrioventricular Bundle/complications , Accessory Atrioventricular Bundle/surgery , Echocardiography/methods , Ventricular Function, Left , Tachycardia, Supraventricular/complications
SELECTION OF CITATIONS