Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 2.973
Filter
1.
Syst Rev ; 13(1): 150, 2024 Jun 05.
Article in English | MEDLINE | ID: mdl-38840193

ABSTRACT

BACKGROUND: Clinical trials investigating acetabular fractures are heterogeneous in their investigated outcomes and their corresponding measurements. Standardization may facilitate comparability and pooling of research results, which would lead to an increase in knowledge about the optimal treatment of acetabular fractures, resulting in long-term evidence-based treatment decisions and improvements in patient care. The aim of this systematic review is to identify the reported outcomes and their measurements from studies on treatments for acetabular fractures to develop a core outcome set which contains the most relevant outcome measures to be included in future studies. METHODS: Studies published in English and German including patients aged 16 years and older, with a surgically treated acetabular fracture, will be included. Studies with nonsurgical treatment, pathologic fractures, polytraumatized patients, and patients younger than 16 years of age will be excluded because other outcomes may be of interest in these cases. Any prospective and retrospective study will be included. Systematic reviews will be excluded, but their included studies will be screened for eligibility. The literature will be searched on MEDLINE, CENTRAL, Web of Science, ClinicalTrials.gov, and WHO ICTRP. Risk of selective reporting of outcomes will be assessed using the Outcome Reporting Bias in Trials classification system. Heterogeneously defined outcomes that measure the same outcome will be grouped and subsequently categorized into outcome domains using the taxonomy of the Core Outcome Measures in Effectiveness Trials Initiative. DISCUSSION: It is expected that a high number of studies will be included, and many outcomes will be identified using different definitions and measurement instruments. A limitation of this systematic review is that only previously investigated outcomes will be detected, thus disregarding potentially relevant outcomes. SYSTEMATIC REVIEW REGISTRATION: PROSPERO CRD42022357644.


Subject(s)
Acetabulum , Fractures, Bone , Systematic Reviews as Topic , Humans , Acetabulum/injuries , Fractures, Bone/therapy , Outcome Assessment, Health Care , Research Design
2.
PLoS One ; 19(6): e0300256, 2024.
Article in English | MEDLINE | ID: mdl-38829845

ABSTRACT

PURPOSE: Due to the increase in life expectancy and high-energy traumas, anterior column acetabular fractures (ACFs) are also increasing. While open reduction and internal fixation (ORIF) is still the standard surgical procedure, minimally invasive, percutaneous fixation of osteoporotic acetabulum fractures (AF) are growing in popularity. The aim of this biomechanical study was to evaluate the biomechanical competence following antegrade fixation with a standard screw versus a cannulated compression headless screw. METHODS: Eight anatomical osteoporotic composite pelvises were given an anterior column fracture. Two groups of eight specimens each (n = 8) for fixation with either a 6.5 mm cannulated compression headless screw in group Anterior Acetabulum Canulated Compression Headless Screw (AACCH), or with a 6.5 mm partially threaded cannulated screw in group Anterior Acetabulum Standard Screw (AASS) where compared. Each specimen was biomechanically loaded cyclically at a rate of 2 Hz with monotonically increasing compressive load until failure. Motions were assessed by means of optical motion tracking. RESULTS: Initial construct stiffness trended higher in group AACCH at 152.4 ± 23.1 N/mm compared to group AASS at 118.5 ± 34.3 N/mm, p = 0.051. Numbers of cycles and corresponding peak load at failure, were significantly higher in group AACCH at 6734 ± 1669 cycles and 873.4 ± 166.9 N versus group AASS at 4440 ± 2063 cycles and 644.0 ± 206.3 N, p = 0.041. Failure modes were breakout of the screws around the proximal entry point. CONCLUSION: From a biomechanical perspective, group AACCH was associated with superior biomechanical competence compared to standard partially threaded cannulated screws and could therefore be considered as valid alternative for fixation of anterior acetabulum fractures.


Subject(s)
Acetabulum , Bone Screws , Fracture Fixation, Internal , Acetabulum/surgery , Acetabulum/injuries , Humans , Fracture Fixation, Internal/methods , Fracture Fixation, Internal/instrumentation , Biomechanical Phenomena , Fractures, Bone/surgery , Osteoporosis/surgery , Osteoporosis/physiopathology , Osteoporosis/complications
3.
Int J Nanomedicine ; 19: 4515-4531, 2024.
Article in English | MEDLINE | ID: mdl-38803996

ABSTRACT

Introduction: There is an ongoing need for improved healing response and expedited osseointegration on the Ti implants in acetabular fracture sites. To achieve adequate bonding and mechanical stability between the implant surface and the acetabular fracture, a new coating technology must be developed to promote bone integration and prevent bacterial growth. Methods: A cylindrical Ti substrate mounted on a rotating specimen holder was used to implant Ca2+, P2+, and Sr2+ ions at energies of 100 KeV, 75 KeV and 180 KeV, respectively, using a low-energy accelerator to synthesize strontium-substituted hydroxyapatite at varying conditions. Ag2+ ions of energy 100 KeV were subsequently implanted on the as-formed surface at the near-surface region to provide anti-bacterial properties to the as-formed specimen. Results: The properties of the as-formed ion-implanted specimen were compared with the SrHA-Ag synthesized specimens by cathodic deposition and low-temperature high-speed collision technique. The adhesion strength of the ion-implanted specimen was 43 ± 2.3 MPa, which is well above the ASTM standard for Ca-P coating on Ti. Live/dead cell analysis showed higher osteoblast activity on the ion-implanted specimen than the other two. Ag in the SrHA implanted Ti by ion implantation process showed superior antibacterial activity. Discussion: In the ion implantation technique, nano-topography patterned surfaces are not concealed after implantation, and their efficacy in interacting with the osteoblasts is retained. Although all three studies examined the antibacterial effects of Ag2+ ions and the ability to promote bone tissue formation by MC3T3-E1 cells on SrHA-Ag/Ti surfaces, ion implantation techniques demonstrated superior ability. The synthesized specimen can be used as an effective implant in acetabular fracture sites based on their mechanical and biological properties.


Subject(s)
Acetabulum , Anti-Bacterial Agents , Silver , Strontium , Titanium , Titanium/chemistry , Titanium/pharmacology , Silver/chemistry , Silver/pharmacology , Strontium/chemistry , Strontium/pharmacology , Anti-Bacterial Agents/pharmacology , Anti-Bacterial Agents/chemistry , Acetabulum/injuries , Animals , Coated Materials, Biocompatible/chemistry , Coated Materials, Biocompatible/pharmacology , Osseointegration/drug effects , Mice , Surface Properties , Fractures, Bone/therapy , Durapatite/chemistry , Durapatite/pharmacology , Osteoblasts/drug effects , Hydroxyapatites/chemistry , Hydroxyapatites/pharmacology , Prostheses and Implants , Ions/chemistry , Ions/pharmacology , Humans , Cell Line
4.
J Orthop Surg Res ; 19(1): 298, 2024 May 16.
Article in English | MEDLINE | ID: mdl-38755648

ABSTRACT

BACKGROUND: A new classification system for acetabular fractures has been proposed in recent years, which is called the 3-column classification. However, this system does not provide information regarding quadrilateral plate fractures. To address this issue, we utilized three-dimensional (3D) fracture line mapping and heat map to analyze the link between the 3-column classification and quadrilateral plate fractures. METHODS: We collected CT scan data from 177 patients who had been diagnosed with acetabular fractures. Additionally, we utilized a CT scan of a healthy adult to generate a standard acetabular model. We utilized the collected CT data of the fracture to create a 3D model and subsequently reduced it. We then matched each acetabular fracture model with the standard acetabular model and mapped all of the fracture lines to the standard model. 3D fracture lines and heat maps were created by overlapping all fracture lines. Fracture characteristics were then summarized using these maps. RESULTS: This study analyzed a total of 221 acetabular fractures. The most frequently observed fracture type, based on the three-column classification, was A1.2, which corresponds to fractures of the anterior column. In contrast, the least common type of fracture was A4, which represents fractures of the central wall. It was noted that quadrilateral plate fractures were frequently observed in fractures classified as type B and C according to the three-column classification. CONCLUSIONS: Among the three-column classification, the QLP fractures are commonly observed in type B and C. It is important to carefully identify these fractures during the diagnostic process. Therefore, based on the three-column classification, we have amalgamated quadrilateral plate fractures and formulated a classification program for acetabular fractures.


Subject(s)
Acetabulum , Fractures, Bone , Imaging, Three-Dimensional , Tomography, X-Ray Computed , Humans , Acetabulum/injuries , Acetabulum/diagnostic imaging , Female , Male , Adult , Fractures, Bone/classification , Fractures, Bone/diagnostic imaging , Imaging, Three-Dimensional/methods , Middle Aged , Tomography, X-Ray Computed/methods , Aged , Young Adult , Aged, 80 and over , Adolescent
5.
Medicine (Baltimore) ; 103(20): e38252, 2024 May 17.
Article in English | MEDLINE | ID: mdl-38758854

ABSTRACT

The management of comminuted quadrilateral fractures remains challenging, and treatment options are constantly evolving. The purpose of the present study was to examine the outcomes of 2 different fixation techniques in the management of comminuted quadrilateral fractures. Twenty-two patients with comminuted quadrilateral acetabular fractures were surgically treated with interfragmentary lag screw (group 1) and square bracket-shaped tubular (SBST) plate technique (group 2), in addition to suprapectineal and infrapectineal pelvic reconstruction plate fixation between January 2016 and July 2019 at our clinic. 2 years follow-up control data of each group were compared in terms of radiological and functional results, and complications. According to the functional score comparison, the mean Merle d'Aubigne Postel scoring system (MAP) score was 15.2/15.6 (P = .632), and the mean Harris hip scoring (HHS) system score was 74.65/77.3 (P = .664) in groups 1 and 2, respectively. Radiological comparison was performed according to matta radiological criteria (MRC), and 2 excellent, 6 good, 2 poor, 4 excellent, 4 good, and 4 poor radiological results were observed in groups 1 and 2, respectively. intraarticular screw penetration was detected in 3 patients in group 1, while there was no articular implant penetration in group 2 (P = .001). We believe that satisfactory results can be obtained with the SBST plate technique, offering functional and clinical outcomes that are similar to those of the interfragmentary screw technique. The SBST plate technique is superior in terms of avoiding intraarticular screw penetration and related revision surgery.


Subject(s)
Acetabulum , Bone Plates , Bone Screws , Fracture Fixation, Internal , Fractures, Comminuted , Humans , Acetabulum/surgery , Acetabulum/injuries , Acetabulum/diagnostic imaging , Female , Male , Fracture Fixation, Internal/methods , Fracture Fixation, Internal/instrumentation , Middle Aged , Adult , Fractures, Comminuted/surgery , Fractures, Comminuted/diagnostic imaging , Treatment Outcome , Retrospective Studies , Fractures, Bone/surgery , Fractures, Bone/diagnostic imaging
6.
BMC Surg ; 24(1): 157, 2024 May 16.
Article in English | MEDLINE | ID: mdl-38755649

ABSTRACT

BACKGROUND: Fractures involving the posterior acetabulum with its rich vascular and neural supply present challenges in trauma orthopedics. This study evaluates the effectiveness of 3D printing technology with the use of custom-made metal plates in the treatment of posterior wall and column acetabular fractures. METHODS: A retrospective analysis included 31 patients undergoing surgical fixation for posterior wall and column fractures of the acetabulum (16 in the 3D printing group, utilizing 3D printing for a 1:1 pelvic model and custom-made plates based on preoperative simulation; 15 in the traditional group, using conventional methods). Surgical and instrument operation times, intraoperative fluoroscopy frequency, intraoperative blood loss, fracture reduction quality, fracture healing time, preoperative and 12-month postoperative pain scores (Numeric Rating Scale, NRS), hip joint function at 6 and 12 months (Harris scores), and complications were compared. RESULTS: The surgical and instrument operation times were significantly shorter in the 3D printing group (p < 0.001). The 3D printing group exhibited significantly lower intraoperative fluoroscopy frequency and blood loss (p = 0.001 and p < 0.001, respectively). No significant differences were observed between the two groups in terms of fracture reduction quality, fracture healing time, preoperative pain scores (NRS scores), and 6-month hip joint function (Harris scores) (p > 0.05). However, at 12 months, hip joint function and pain scores were significantly better in the 3D printing group (p < 0.05). Although the incidence of complications was lower in the 3D printing group (18.8% vs. 33.3%), the difference did not reach statistical significance (p = 0.433). CONCLUSION: Combining 3D printing with individualized custom-made metal plates for acetabular posterior wall and column fractures reduces surgery and instrument time, minimizes intraoperative procedures and blood loss, enhancing long-term hip joint function recovery. CLINICAL TRIAL REGISTRATION: 12/04/2023;Trial Registration No. ChiCTR2300070438; http://www.chictr.org.cn .


Subject(s)
Acetabulum , Bone Plates , Fracture Fixation, Internal , Fractures, Bone , Printing, Three-Dimensional , Humans , Retrospective Studies , Acetabulum/surgery , Acetabulum/injuries , Male , Female , Adult , Middle Aged , Fracture Fixation, Internal/methods , Fracture Fixation, Internal/instrumentation , Treatment Outcome , Fractures, Bone/surgery , Operative Time , Young Adult , Prosthesis Design , Aged
7.
Article in English | MEDLINE | ID: mdl-38768051

ABSTRACT

INTRODUCTION: Diabetes mellitus (DM) is a risk factor of infection. Although DM has been associated with worse functional outcomes after acetabular fracture, literature regarding the effect of DM on surgical site infection and other early complications is lacking. METHODS: A 20-year registry from a level 1 trauma center was queried to identify 134 patients with DM and 345 nondiabetic patients with acetabular fractures. RESULTS: The diabetic patient population was older (57.2 versus 43.2; P < 0.001) and had higher average body mass index (33.6 versus 29.5; P < 0.001). Eighty-three patients with DM and 270 nondiabetics were treated surgically (62% versus 78%; P < 0.001). Diabetic patients who were younger (54.6 versus 61.4; P = 0.01) with fewer comorbidities (1.7 versus 2.2; P = 0.04) were more frequently managed surgically. On univariate analysis, patients with DM more commonly developed any early infection (28.4% versus 21%; P = 0.049) but were no more likely to develop surgical site infection, or other postoperative complications. Older patient age, length of stay, baseline pulmonary disease, and concurrent abdominal injury were independent predictors of postoperative infection other than surgical site infection. Diabetics that developed infection had more comorbidities (2.4 versus 1.5; P < 0.001) and higher Injury Severity Score (24.1 versus 15.8; P = 0.003), and were more frequently insulin-dependent (72.7% versus 41%; P = 0.01). DISCUSSION: Independent of management strategy, diabetic patients were more likely to develop an infection after acetabular fracture. Insulin dependence was associated with postoperative infection on univariate analysis. Optimal selection of surgical candidates among patients with DM may limit postoperative infections.


Subject(s)
Acetabulum , Fractures, Bone , Registries , Surgical Wound Infection , Trauma Centers , Humans , Male , Female , Middle Aged , Adult , Fractures, Bone/surgery , Fractures, Bone/epidemiology , Surgical Wound Infection/epidemiology , Surgical Wound Infection/etiology , Acetabulum/injuries , Acetabulum/surgery , Aged , Diabetes Mellitus/epidemiology , Retrospective Studies , Risk Factors , Diabetes Complications
8.
BMC Musculoskelet Disord ; 25(1): 417, 2024 May 28.
Article in English | MEDLINE | ID: mdl-38807120

ABSTRACT

OBJECTIVE: To digitally measure the fixation trajectory of anatomical plates used in the combined reduction of quadrilateral acetabular fractures via the posterior approach, and to develop anatomical plates that align with the characteristics of the pelvis in the Chinese population. METHODS: Pelvic computed tomography (CT) data from 102 adult patients were collected at the Affiliated Hospital of Zunyi Medical University. This group included 51 males and 51 females, aged between 20 and 60 years. Using Mimics software (version 21.0), a three-dimensional model of each pelvic data point was reconstructed. The fixation path for the combined reset anatomical steel plate was drawn, where the curves on the fixation path were approximated as arcs. The radius of curvature and length of these curves were measured, and an anatomical steel plate was designed to best fit the pelvic structure. RESULTS: The combined anatomical reduction plate fixation system for quadrilateral acetabular fractures using a posterior approach consisted of two parts: a locking plate and a reduction plate. The posterior wall region (r2), ischial region (r3), quadrilateral region (r4), and bending region (r5), and the total length of the reduction plate were significantly smaller in females (P < 0.05). Similarly, the posterior wall region (R3), distal posterior wall region (R4), and the total length of the locking plate were significantly smaller in females (P < 0.05). Additionally, the anterior superior iliac spine side (r1) and the total length of the T-shaped auxiliary plate were significantly smaller in females (P < 0.05). The bending angle (< A) was also significantly smaller in females (P < 0.05). CONCLUSIONS: The pelvic surface structure is irregular and varies greatly among individuals.Compared to the traditional steel plate, The combined reduction anatomical plate designed in this study demonstrated high precision and improved conformity to the anatomical structure of the pelvis.


Subject(s)
Acetabulum , Bone Plates , Fracture Fixation, Internal , Fractures, Bone , Tomography, X-Ray Computed , Humans , Female , Male , Acetabulum/diagnostic imaging , Acetabulum/injuries , Acetabulum/surgery , Adult , Middle Aged , Fracture Fixation, Internal/methods , Fracture Fixation, Internal/instrumentation , Fractures, Bone/surgery , Fractures, Bone/diagnostic imaging , Young Adult , Imaging, Three-Dimensional
9.
J Med Life ; 17(2): 188-194, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38813362

ABSTRACT

This study aimed to share our experience of a self-developed plate for acetabular fracture fixation through the presentation of clinical cases. Eight patients with complex acetabular fractures (Letournel classification) underwent surgery using a modified Stoppa approach and the novel plate design between 2021 and 2023 at the National Scientific Center for Traumatology and Orthopedics. Criteria such as the mechanism of injury, type of fracture, surgical approach, intraoperative and postoperative complications, quality of reduction, and functional and radiological results were evaluated. All patients included in the study presented complex types of acetabular fractures according to the Letournel classification. In all cases, surgical interventions were performed using a modified Stoppa approach. The assessment of reduction quality was conducted based on the radiological standards established by Matta. The reduction in quality was excellent in two patients, good in four, and satisfactory in two. One patient developed a post-traumatic false joint requiring additional surgery. The remaining patients achieved fracture healing with satisfactory Harris Hip Score (HHS) scores, indicating good overall function. The results of the self-developed plate for acetabular fracture fixation in our series were satisfactory.


Subject(s)
Acetabulum , Bone Plates , Fracture Fixation, Internal , Fractures, Bone , Humans , Acetabulum/surgery , Acetabulum/injuries , Male , Adult , Female , Fractures, Bone/surgery , Fractures, Bone/diagnostic imaging , Fracture Fixation, Internal/methods , Middle Aged , Young Adult
10.
BMC Geriatr ; 24(1): 314, 2024 Apr 04.
Article in English | MEDLINE | ID: mdl-38575871

ABSTRACT

BACKGROUND AND OBJECTIVES: It is known that difficulty sleeping after a fracture can have negative effects on both mental and physical health and may prolong the recovery process. The objective of this study is to explore how sleep quality and psychological health are linked in patients with pelvic and acetabulum fractures. METHODS: A study was conducted on 265 patients between 2018 and 2022 who had suffered pelvic and acetabulum fractures. The study examined various factors, including age, gender, cause of injury, post-operative complications, and injury severity. The study employed ordinal logistic regression to examine the relationship between various pelvic fractures and seven subscales of the Majeed Pelvic Score (MPS), as well as the Sleep Disorder Questionnaire (SDQ) and Beck Depression Inventory (BDI). The study focused on the postoperative outcome one year after surgery, and each patient was assessed at the one-year mark after surgical intervention. Additionally, the study evaluated the functional outcome, sleep quality, and psychological disorders of the patients. RESULTS: From 2018 to 2022, a total of 216 patients suffered from pelvic and acetabulum fractures. Among them, 6.6% experienced borderline clinical depression, and 45.2% reported mild mood disturbances. Anxiety was found to be mild to moderate in 46% of Tile C and posterior acetabulum wall fracture patients. About 24.8% of patients reported insomnia, while 23.1% reported sleep movement disorders. However, no significant correlation was found between fracture types and sleep disorders. The mean Majeed pelvic score (MPS) was 89.68. CONCLUSIONS: Patients with pelvic and acetabular fractures typically experience functional improvement, but may also be at increased risk for insomnia and sleep movement disorders, particularly for certain types of fractures. Psychological well-being varies between fracture groups, with signs of borderline clinical depression observed in some cases. However, anxiety levels do not appear to be significantly correlated with pelvic and acetabular fractures.


Subject(s)
Fractures, Bone , Hip Fractures , Movement Disorders , Pelvic Bones , Sleep Initiation and Maintenance Disorders , Spinal Fractures , Humans , Acetabulum/injuries , Cross-Sectional Studies , Sleep Quality , Fractures, Bone/complications , Fractures, Bone/epidemiology , Fractures, Bone/surgery , Pelvic Bones/surgery , Pelvic Bones/injuries , Retrospective Studies
11.
J Orthop Surg Res ; 19(1): 253, 2024 Apr 22.
Article in English | MEDLINE | ID: mdl-38644485

ABSTRACT

INTRODUCTION: We present a detailed procedure for the robotic-assisted plate osteosynthesis of an anterior acetabular fracture. The purpose of this work was to describe a robotic-assisted minimally invasive technique as a possible method for reducing complications, pain, and hospitalization. Another goal was to present technical recommendations and to assess potential pitfalls and problems of the new surgical approach. METHODS: Surgery was performed in an interdisciplinary setting by an experienced orthopedic surgeon and a urologist. The DaVinci System with standard instruments was used. Reduction was achieved through indirect traction of a pin that was introduced into the femoral neck and direct manipulation via the plate. The plate position and fixation were achieved through 7 additional minimally invasive incisions. RESULTS: The technique has multiple advantages, such as no detachment of the rectus abdominal muscle, a small skin incision, and minimal blood loss. Furthermore, this approach might lower the incidence of hernia formation, infection, and postoperative pain. DISCUSSION: We see the presented technique as a demanding yet progressive and innovative surgical method for treating acetabular fractures with indications for anterior plate fixation. TRIAL REGISTRATION: The study was approved by the local institutional review board (Nr. 248/18).


Subject(s)
Acetabulum , Bone Plates , Fracture Fixation, Internal , Fractures, Bone , Robotic Surgical Procedures , Humans , Acetabulum/surgery , Acetabulum/injuries , Robotic Surgical Procedures/methods , Fracture Fixation, Internal/methods , Fracture Fixation, Internal/instrumentation , Fractures, Bone/surgery , Male , Minimally Invasive Surgical Procedures/methods , Minimally Invasive Surgical Procedures/instrumentation , Female , Adult
12.
Acta Orthop Belg ; 90(1): 17-25, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38669644

ABSTRACT

Today, acetabular surgeons in training have to learn ilioinguinal and anterior intrapelvic approaches (AIP). The aim of this study was to describe the 5-years learning curve of a surgeon. Objective was to assess clinical and radiological results; and to assess factors which could influence this learning curve. Between November 2015 and May 2020, patients with an acetabular fracture operated by the surgeon during the 5-years learning curve with an anterior approach were included in this single-center retrospective study based on a prospective database. Epidemiological, operative, clinical, radiological and complications data's were collected. To assess learning-curve effect the series was divided into two groups: first 2.5-years and last 2-years. Subgroup analysis were performed according to the surgical approach, to the reduction quality and the prognostic factors. In total, 46 patients were included, 23 in period 1 and 23 in period 2. 16 patients (35%) had ilioinguinal approach and 30 patients (65%) had modified Stoppa-Cole approach. At mean follow-up of 24 months, 38 patients (83%) were reviewed. Anatomical reduction (< 1 mm) was achieved in 28 patients (60.9%) with a 9% rate of perioperative complications and 37% rate of post-operative complications. In conclusion, this study gives a realistic overview of the learning curve of anterior approaches in acetabular fractures surgery. Our results should encourage surgeons, while keeping in mind how much this surgery can be challenging, with high rate of complications and difficulty to obtain a systematic anatomical reduction.


Subject(s)
Acetabulum , Fractures, Bone , Learning Curve , Humans , Acetabulum/injuries , Acetabulum/surgery , Acetabulum/diagnostic imaging , Male , Female , Retrospective Studies , Fractures, Bone/surgery , Middle Aged , Adult , Fracture Fixation, Internal/methods , Postoperative Complications/epidemiology , Aged
13.
J Bone Joint Surg Am ; 106(11): 1000-1007, 2024 Jun 05.
Article in English | MEDLINE | ID: mdl-38557970

ABSTRACT

BACKGROUND: Although high-energy trauma mechanisms are generally considered to cause traumatic posterior hip dislocations, femoroacetabular variations are assumed to contribute to low-impact hip dislocations. Thus, the present study aimed to identify morphologic femoral and acetabular risk factors that may also contribute to posterior hip dislocations in high-energy trauma mechanisms. METHODS: The acetabular and femoral morphology of 83 hips with a traumatic posterior dislocation following a high-energy trauma mechanism were analyzed and matched to a control group of 83 patients who sustained high-energy trauma without a hip injury. The lateral center-edge angle, acetabular index, acetabular depth/width ratio, cranial and central acetabular version angles, and the anterior and posterior acetabular sector angles were measured on computed tomography to quantify femoroacetabular impingement (FAI) morphology, acetabular version, and coverage. The caput-collum-diaphyseal angle and the alpha angles in the coronal and axial planes were measured to detect cam-type FAI deformity. A receiver operating characteristic curve was utilized to determine threshold values for an increased risk of hip dislocation. RESULTS: Acetabular retroversion and posterior acetabular undercoverage were significantly increased in patients with hip dislocations compared with controls (p < 0.001). The central acetabular version angle and posterior acetabular sector angle that indicated an increased risk of hip dislocation were ≤9° and ≤90°, respectively. Cam-type FAI deformity and coxa valga were significantly increased in the dislocation group (p < 0.001). The anterolateral alpha angle that indicated an increased dislocation risk was ≥47°. CONCLUSIONS: Acetabular retroversion, posterior acetabular undercoverage, and cam-type FAI morphology may be risk factors contributing to traumatic posterior hip dislocation in high-energy trauma mechanisms. LEVEL OF EVIDENCE: Prognostic Level III . See Instructions for Authors for a complete description of levels of evidence.


Subject(s)
Acetabulum , Femoracetabular Impingement , Hip Dislocation , Tomography, X-Ray Computed , Humans , Female , Male , Hip Dislocation/diagnostic imaging , Hip Dislocation/etiology , Adult , Acetabulum/injuries , Acetabulum/diagnostic imaging , Femoracetabular Impingement/diagnostic imaging , Middle Aged , Risk Factors , Young Adult , Femur/diagnostic imaging , Retrospective Studies , Case-Control Studies , Adolescent
14.
J Am Acad Orthop Surg ; 32(12): 550-557, 2024 Jun 15.
Article in English | MEDLINE | ID: mdl-38595147

ABSTRACT

BACKGROUND: The management of elderly acetabular fractures is complex, with high rates of conversion total hip arthroplasty (THA) after open reduction and internal fixation (ORIF), but potentially higher rates of complications after acute THA. METHODS: The California Office of Statewide Health Planning and Development database was queried between 2010 and 2017 for all patients aged 60 years or older who sustained a closed, isolated acetabular fracture and underwent ORIF, THA, or a combination. Chi-square tests and Student t tests were used to identify demographic differences between groups. Multivariate regression was used to evaluate predictors of 30-day readmission and 90-day complications. Kaplan-Meier (KM) survival analysis and Cox proportional hazards model were used to estimate the revision surgery-free survival (revision-free survival [RFS]), with revision surgery defined as conversion THA, revision ORIF, or revision THA. RESULTS: A total of 2,184 surgically managed acetabular fractures in elderly patients were identified, with 1,637 (75.0%) undergoing ORIF and 547 (25.0%) undergoing THA with or without ORIF. Median follow-up was 295 days (interquartile range, 13 to 1720 days). 99.4% of revisions following ORIF were for conversion arthroplasty. Unadjusted KM analysis showed no difference in RFS between ORIF and THA (log-rank test P = 0.27). RFS for ORIF patients was 95.1%, 85.8%, 78.3%, and 71.4% at 6, 12, 24 and 60 months, respectively. RFS for THA patients was 91.6%, 88.9%, 87.2%, and 78.8% at 6, 12, 24 and 60 months, respectively. Roughly 50% of revisions occurred within the first year postoperatively (49% for ORIF, 52% for THA). In propensity score-matched analysis, there was no difference between RFS on KM analysis ( P = 0.22). CONCLUSIONS: No difference was observed in medium-term RFS between acute THA and ORIF for elderly acetabular fractures in California. Revision surgeries for either conversion or revision THA were relatively common in both groups, with roughly half of all revisions occurring within the first year postoperatively. LEVEL OF EVIDENCE: III.


Subject(s)
Acetabulum , Arthroplasty, Replacement, Hip , Fracture Fixation, Internal , Fractures, Bone , Open Fracture Reduction , Reoperation , Humans , Reoperation/statistics & numerical data , Aged , Arthroplasty, Replacement, Hip/adverse effects , Acetabulum/injuries , Acetabulum/surgery , Female , Male , Fracture Fixation, Internal/methods , Fracture Fixation, Internal/adverse effects , Fractures, Bone/surgery , Aged, 80 and over , Middle Aged , Postoperative Complications/epidemiology , Postoperative Complications/etiology , Retrospective Studies
16.
Injury ; 55(6): 111518, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38614834

ABSTRACT

INTRODUCTION: Post-operative pelvic & acetabular fixation patients are conventionally imaged using 3-view radiographs (AP, inlet and outlet). The efficacy of such radiographs is inconsistent due to technical difficulties capturing an adequate view, often necessitating repeat radiographs and therefore increasing radiation exposure. Radiographs can be difficult to interpret, limiting the assessment of fracture reduction and fixation, especially with respect to metalwork positioning around articular surfaces. Traditionally, post-operative pelvic & acetabular fixation patients undergo repeat 3-view radiographs post-operatively, at 6 weeks, followed by at 3, 6, 12, 18 and 24 months. We propose a new pathway, in which patients have one low-dose pelvic CT immediately post-operatively, followed by one radiograph (AP pelvis) at the same time points. METHODS: A new pelvic CT protocol was created to provide high quality 3D imaging whilst delivering a 5 times lower radiation dose (compared to normal pelvic CT). Data for all pelvic radiographs and CTs between January 2021 and March 2022 was exported. Using dose area product values, effective radiation dose and attributable lifetime cancer risk were calculated. RESULTS: There were 42 patients included in the analysis (age range 15 to 87).The average effective dose for the 3-view pelvic X-rays was 0.6mSv (range 0.2 to 2.8mSv), and 1.1mSv (range 0.5 to 2.2mSv) for the low-dose pelvic CT. Traditional 7 × 3-view post-operative radiographs: 7 × 0.6mSv = 4.2mSv (corresponding to 1 in 11,000 cancer risk) Low dose post-operative CT and 6 × 1-view radiographs: 1.1mSv + (6 × 0.6mSv / 3) = 2.3mSv (corresponding to 1 in 20,000 cancer risk) CONCLUSION: Low-dose CT scanning (in conjunction with 1-view radiographs) is an effective and safe imaging modality in the post-operative assessment of pelvic & acetabular fracture fixation, conferring a lower radiation burden, easier logistics, and higher quality images when compared to the traditional pathway of 3-view radiographs.


Subject(s)
Acetabulum , Fracture Fixation, Internal , Fractures, Bone , Pelvic Bones , Radiation Dosage , Tomography, X-Ray Computed , Humans , Acetabulum/surgery , Acetabulum/diagnostic imaging , Acetabulum/injuries , Female , Male , Middle Aged , Adult , Fractures, Bone/diagnostic imaging , Fractures, Bone/surgery , Aged , Pelvic Bones/diagnostic imaging , Pelvic Bones/injuries , Pelvic Bones/surgery , Adolescent , Aged, 80 and over , Fracture Fixation, Internal/methods , Young Adult , Imaging, Three-Dimensional , Postoperative Care/methods , Retrospective Studies , Postoperative Period , Radiation Exposure
17.
Injury ; 55(6): 111519, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38584077

ABSTRACT

BACKGROUND: In this study, we investigated the area that can be addressed with an approach in which the skin incision is made directly above the dorsal column with Thiel cadaveric specimens. METHODS: Six Thiel cadaveric specimens were prepared. A skin incision was made directly above the dorsal column. The accessible proximal end from the proximal part of the greater sciatic notch to the gluteal ridge and the accessible distal end of the ischium were marked with a flat chisel. A molded 8-hole reconstruction plate was placed from the base of the ischium toward the gluteal ridge and fixed with 3 screws proximally and 2 screws distally. The length of the skin incision and the distance from each reference point on the bone to the reachable markings were assessed after the muscles were removed. RESULTS: Mean skin incision length was 9.3 ± 0.7 (range, 8.0-10.0) cm. In 3 of 6 cases, proximal screws were inserted through different spaces between muscle fibers. In all cases, we were able to reach at least the greater sciatic notch, the gluteal ridge at the level of superior border of the acetabulum, and the base of the ischial tuberosity. In all cases, an 8-hole plate could be placed from the gluteal ridge to the base of the ischium. There were no superior gluteal artery or sciatic nerve injuries in any of the cases. CONCLUSION: We anatomically investigated the area that can be addressed with an approach in which the skin incision was made directly above the dorsal column. In all cases, we were able to access the areas needed to reduce the fracture and place the plates necessary to stabilize the fracture through a 9.3 ± 0.7 cm skin incision. This approach can be a useful minimally invasive posterior approach for acetabular fractures.


Subject(s)
Acetabulum , Bone Plates , Cadaver , Fracture Fixation, Internal , Fractures, Bone , Humans , Acetabulum/injuries , Acetabulum/surgery , Acetabulum/anatomy & histology , Buttocks/surgery , Buttocks/blood supply , Buttocks/injuries , Fracture Fixation, Internal/methods , Fractures, Bone/surgery , Bone Screws , Male , Female , Ischium/surgery , Ischium/anatomy & histology , Aged
18.
Bone Joint J ; 106-B(5 Supple B): 11-16, 2024 May 01.
Article in English | MEDLINE | ID: mdl-38688486

ABSTRACT

Aims: Lateral femoral cutaneous nerve (LFCN) injury is a complication after periacetabular osteo-tomy (PAO) using an anterior approach, which might adversely affect the outcome. However, no prospective study has assessed the incidence and severity of this injury and its effect on the clinical outcomes over a period of time for longer than one year after PAO. The aim of this study was to assess the incidence and severity of the symptoms of LFCN injury for ≥ three years after PAO and report its effect on clinical outcomes. Methods: A total of 40 hips in 40 consecutive patients who underwent PAO between May 2016 and July 2018 were included in the study, as further follow-up of the same patients from a previous study. We prospectively evaluated the incidence, severity, and area of symptoms following LFCN injury. We also recorded the clinical scores at one year and ≥ three years postoperatively using the 36-Item Short Form Health Survey (SF-36) and Japanese Orthopaedic Association Hip Disease Evaluation Questionnaire (JHEQ) scores. Results: A total of 20 patients (50%) had symptoms of a LFCN injury at one year after PAO. At ≥ three years postoperatively, the symptoms had completely resolved in seven of these patients and 13 (33%) had persistent symptoms. The severity and area of symptoms did not significantly differ between one and ≥ three years postoperatively. The JHEQ showed significant differences in the patient satisfaction and mental scores between those with and those without sypmtoms of LFCN injury at ≥ three years postoperatively, while there was no significant difference in the mean SF-36 scores. Conclusion: The incidence of LFCN injury after PAO using an anterior approach is high. The outcome of PAO, ≥ three years postoperatively, is poorer in patients with persistent symptoms from a perioperative LFCN injury, in that patient satisfaction and mental health scores are adversely affected.


Subject(s)
Acetabulum , Osteotomy , Peripheral Nerve Injuries , Postoperative Complications , Humans , Female , Male , Incidence , Adult , Osteotomy/adverse effects , Osteotomy/methods , Acetabulum/surgery , Acetabulum/injuries , Prospective Studies , Postoperative Complications/epidemiology , Postoperative Complications/etiology , Peripheral Nerve Injuries/etiology , Peripheral Nerve Injuries/epidemiology , Middle Aged , Femoral Nerve/injuries , Young Adult , Treatment Outcome , Adolescent
19.
Bone Joint J ; 106-B(5 Supple B): 133-138, 2024 May 01.
Article in English | MEDLINE | ID: mdl-38688506

ABSTRACT

Aims: Dual-mobility acetabular components (DMCs) have improved total hip arthroplasty (THA) stability in femoral neck fractures (FNFs). In osteoarthritis, the direct anterior approach (DAA) has been promoted for improving early functional results compared with the posterolateral approach (PLA). The aim of this study was to compare these two approaches in FNF using DMC-THA. Methods: A prospective continuous cohort study was conducted on patients undergoing operation for FNF using DMC by DAA or PLA. Functional outcome was evaluated using the Harris Hip Score (HHS) and Parker score at three months and one year. Perioperative complications were recorded, and radiological component positioning evaluated. Results: There were 50 patients in the DAA group and 54 in the PLA group. The mean HHS was 85.5 (SD 8.8) for the DAA group and 81.8 (SD 11.9) for the PLA group (p = 0.064). In all, 35 patients in the DAA group and 40 in the PLA group returned to their pre-fracture Parker score (p = 0.641) in both groups. No statistically significant differences between groups were found at one year regarding these two scores (p = 0.062 and p = 0.723, respectively). The DAA was associated with more intraoperative complications (p = 0.013). There was one dislocation in each group, and four revisions for DAA and one for PLA, but this difference was not statistically significant. There were also no significant differences regarding blood loss, length of stay, or operating time. Conclusion: In DMC-THA for FNF, DAA did not achieve better functional results than PLA, either at three months or at one year. Moreover, DAA presented an increased risk of intra-operative complications.


Subject(s)
Acetabulum , Arthroplasty, Replacement, Hip , Femoral Neck Fractures , Humans , Arthroplasty, Replacement, Hip/methods , Male , Female , Femoral Neck Fractures/surgery , Aged , Prospective Studies , Middle Aged , Acetabulum/surgery , Acetabulum/injuries , Hip Prosthesis , Treatment Outcome , Aged, 80 and over , Postoperative Complications/etiology , Prosthesis Design
20.
Zhongguo Gu Shang ; 37(3): 319-26, 2024 Mar 25.
Article in Chinese | MEDLINE | ID: mdl-38515423

ABSTRACT

Acetabular quadrilateral plate injury has become a hot spot and focus in the field of orthopaedic trauma and pelvic floor function in recent years. Although there are five fracture types,they are all based on fracture morphology,without considering the pulling force of ligaments,joint capsular and muscles. A perfect classification needs to describe the displacement of bone mass in three-dimensional space to better guide reduction and fixation. The seven incision and exposure methods are still the traditional open-eye surgery,and how to protect the criss-crossing vascular neural network and pelvic organs is still the focus. Quadrilateral defect causes dislocation of artificial hip joint,and quantitative evaluation of quadrilateral defect volume and revision techniques are still a hot topic. In this paper,the viewpoints of three-dimensional network structure of acetabular pelvic vascular anatomy,anatomical surgical target channel and fixation anchor point of acetabular fracture reduction are proposed to design new techniques for accurate and minimally invasive surgical operations,in order to realize the requirements of rapid orthopedic rehabilitation.


Subject(s)
Fractures, Bone , Hip Fractures , Spinal Fractures , Humans , Fracture Fixation, Internal/methods , Fractures, Bone/surgery , Acetabulum/surgery , Acetabulum/injuries , Hip Fractures/surgery , Bone Plates
SELECTION OF CITATIONS
SEARCH DETAIL
...