1.
PLoS One ; 19(6): e0300256, 2024.
Article in English | MEDLINE | ID: mdl-38829845

ABSTRACT

PURPOSE: Due to the increase in life expectancy and high-energy traumas, anterior column acetabular fractures (ACFs) are also increasing. While open reduction and internal fixation (ORIF) is still the standard surgical procedure, minimally invasive, percutaneous fixation of osteoporotic acetabulum fractures (AF) are growing in popularity. The aim of this biomechanical study was to evaluate the biomechanical competence following antegrade fixation with a standard screw versus a cannulated compression headless screw. METHODS: Eight anatomical osteoporotic composite pelvises were given an anterior column fracture. Two groups of eight specimens each (n = 8) for fixation with either a 6.5 mm cannulated compression headless screw in group Anterior Acetabulum Canulated Compression Headless Screw (AACCH), or with a 6.5 mm partially threaded cannulated screw in group Anterior Acetabulum Standard Screw (AASS) where compared. Each specimen was biomechanically loaded cyclically at a rate of 2 Hz with monotonically increasing compressive load until failure. Motions were assessed by means of optical motion tracking. RESULTS: Initial construct stiffness trended higher in group AACCH at 152.4 ± 23.1 N/mm compared to group AASS at 118.5 ± 34.3 N/mm, p = 0.051. Numbers of cycles and corresponding peak load at failure, were significantly higher in group AACCH at 6734 ± 1669 cycles and 873.4 ± 166.9 N versus group AASS at 4440 ± 2063 cycles and 644.0 ± 206.3 N, p = 0.041. Failure modes were breakout of the screws around the proximal entry point. CONCLUSION: From a biomechanical perspective, group AACCH was associated with superior biomechanical competence compared to standard partially threaded cannulated screws and could therefore be considered as valid alternative for fixation of anterior acetabulum fractures.


Subject(s)
Acetabulum , Bone Screws , Fracture Fixation, Internal , Acetabulum/surgery , Acetabulum/injuries , Humans , Fracture Fixation, Internal/methods , Fracture Fixation, Internal/instrumentation , Biomechanical Phenomena , Fractures, Bone/surgery , Osteoporosis/surgery , Osteoporosis/physiopathology , Osteoporosis/complications
2.
Sci Rep ; 14(1): 12643, 2024 06 02.
Article in English | MEDLINE | ID: mdl-38825602

ABSTRACT

This study compared the radiologic and clinical outcomes of a new seven-axis robotic-assisted total hip arthroplasty (THA) and conventional THA. Hundred and four patients were randomly assigned to two groups-the robotic-assisted THA group (RAS group) and the conventional THA group (CON group). The preoperative and postoperative Harris Hip score (HHS), acetabular inclination, anteversion, femoral offset, and leg length discrepancy (LLD) were compared. During the follow-up, no patients had any complications that could be associated with the use of the robot. The proportion of acetabular cups in the safety zone was significantly higher in the RAS group than that in the CON group. The two groups had significantly different mean absolute difference of inclination and anteversion. There was no significant difference in the postoperative HHSs, changes in HHSs, femoral offset, and lower limb length between the two groups. The seven-axis robotic-assisted THA system is safe and effective, and leads to better acetabulum cup positioning compared to conventional THA. The improvements observed in the HHS, LLD, and femoral offset in the RAS group were similar to those in the CON group.Clinical trial registration time: 19/05/2022.Clinical trial registration number: ChiCTR2200060115.


Subject(s)
Arthroplasty, Replacement, Hip , Robotic Surgical Procedures , Humans , Arthroplasty, Replacement, Hip/methods , Arthroplasty, Replacement, Hip/instrumentation , Male , Female , Robotic Surgical Procedures/methods , Middle Aged , Prospective Studies , Aged , Treatment Outcome , Acetabulum/surgery
4.
Bone Joint J ; 106-B(5 Supple B): 17-24, 2024 May 01.
Article in English | MEDLINE | ID: mdl-38689571

ABSTRACT

Aims: Periacetabular osteotomy (PAO) is the preferred treatment for symptomatic acetabular dysplasia in adolescents and young adults. There remains a lack of consensus regarding whether intra-articular procedures such as labral repair or improvement of femoral offset should be performed at the time of PAO or addressed subsequent to PAO if symptoms warrant. The purpose was to determine the rate of subsequent hip arthroscopy (HA) in a contemporary cohort of patients, who underwent PAO in isolation without any intra-articular procedures. Methods: From June 2012 to March 2022, 349 rectus-sparing PAOs were performed and followed for a minimum of one year (mean 6.2 years (1 to 11)). The mean age was 24 years (14 to 46) and 88.8% were female (n = 310). Patients were evaluated at final follow-up for patient-reported outcome measures (PROMs). Clinical records were reviewed for complications or subsequent surgery. Radiographs were reviewed for the following acetabular parameters: lateral centre-edge angle, anterior centre-edge angle, acetabular index, and the alpha-angle (AA). Patients were cross-referenced from the two largest hospital systems in our area to determine if subsequent HA was performed. Descriptive statistics were used to analyze risk factors for HA. Results: A total of 16 hips (15 patients; 4.6%) underwent subsequent HA with labral repair and femoral osteochondroplasty, the most common interventions. For those with a minimum of two years of follow-up, 5.3% (n = 14) underwent subsequent HA. No hips underwent total hip arthroplasty and one revision PAO was performed. Overall, 17 hips (4.9%) experienced a complication and 99 (26.9%) underwent hardware removal. All PROMs improved significantly postoperatively. Radiologically, 80% of hips (n = 279) reached the goal for acetabular correction (77% for acetbular index and 93% for LCEA), with no significant differences between those who underwent subsequent HA and those who did not. Conclusion: Rectus-sparing PAO is associated with a low rate of subsequent HA for intra-articular pathology at a mean of 6.2 years' follow-up (1 to 11). Acetabular correction alone may be sufficient as the primary intervention for the majority of patients with symptomatic acetabular dysplasia.


Subject(s)
Acetabulum , Arthroscopy , Osteotomy , Humans , Female , Male , Adolescent , Osteotomy/methods , Adult , Arthroscopy/methods , Acetabulum/surgery , Acetabulum/diagnostic imaging , Young Adult , Middle Aged , Incidence , Retrospective Studies , Patient Reported Outcome Measures , Postoperative Complications/epidemiology , Follow-Up Studies , Reoperation/statistics & numerical data
5.
BMC Musculoskelet Disord ; 25(1): 384, 2024 May 16.
Article in English | MEDLINE | ID: mdl-38755628

ABSTRACT

BACKGROUND: Customized 3D-printed pelvic implants with a porous structure have revolutionized periacetabular pelvic defect reconstruction after tumor resection, offering improved osteointegration, long-term stability, and anatomical fit. However, the lack of an established classification system hampers implementation and progress. METHODS: We formulated a novel classification system based on pelvic defect morphology and 3D-printed hemipelvis endoprostheses. It integrates surgical approach, osteotomy guide plate and prosthesis design, postoperative rehabilitation plans, and perioperative processes. RESULTS: Retrospectively analyzing 60 patients (31 males, 29 females), we classified them into Type A (15 patients: Aa = 6, Ab = 9), Type B (27 patients: Ba = 15, Bb = 12), Type C (17 patients). All underwent customized osteotomy guide plate-assisted tumor resection and 3D-printed hemipelvic endoprosthesis reconstruction. Follow-up duration was median 36.5 ± 15.0 months (range, 6 to 74 months). The mean operating time was 430.0 ± 106.7 min, intraoperative blood loss 2018.3 ± 1305.6 ml, transfusion volume 2510.0 ± 1778.1 ml. Complications occurred in 13 patients (21.7%), including poor wound healing (10.0%), deep prosthesis infection (6.7%), hip dislocation (3.3%), screw fracture (1.7%), and interface loosening (1.7%). VAS score improved from 5.5 ± 1.4 to 1.7 ± 1.3, MSTS-93 score from 14.8 ± 2.5 to 23.0 ± 5.6. Implant osseointegration success rate was 98.5% (128/130), with one Type Ba patient experiencing distal prosthesis loosening. CONCLUSION: The West China classification may supplement the Enneking and Dunham classification, enhancing interdisciplinary communication and surgical outcomes. However, further validation and wider adoption are required to confirm clinical effectiveness.


Subject(s)
Acetabulum , Bone Neoplasms , Printing, Three-Dimensional , Prosthesis Design , Humans , Female , Male , Retrospective Studies , Adult , Middle Aged , Acetabulum/surgery , Acetabulum/diagnostic imaging , Bone Neoplasms/surgery , Bone Neoplasms/diagnostic imaging , Young Adult , Osteotomy/methods , Plastic Surgery Procedures/methods , Plastic Surgery Procedures/instrumentation , Adolescent , Aged , Treatment Outcome , Postoperative Complications/etiology , Follow-Up Studies , Pelvic Bones/surgery , Pelvic Bones/diagnostic imaging
6.
Medicine (Baltimore) ; 103(20): e38252, 2024 May 17.
Article in English | MEDLINE | ID: mdl-38758854

ABSTRACT

The management of comminuted quadrilateral fractures remains challenging, and treatment options are constantly evolving. The purpose of the present study was to examine the outcomes of 2 different fixation techniques in the management of comminuted quadrilateral fractures. Twenty-two patients with comminuted quadrilateral acetabular fractures were surgically treated with interfragmentary lag screw (group 1) and square bracket-shaped tubular (SBST) plate technique (group 2), in addition to suprapectineal and infrapectineal pelvic reconstruction plate fixation between January 2016 and July 2019 at our clinic. 2 years follow-up control data of each group were compared in terms of radiological and functional results, and complications. According to the functional score comparison, the mean Merle d'Aubigne Postel scoring system (MAP) score was 15.2/15.6 (P = .632), and the mean Harris hip scoring (HHS) system score was 74.65/77.3 (P = .664) in groups 1 and 2, respectively. Radiological comparison was performed according to matta radiological criteria (MRC), and 2 excellent, 6 good, 2 poor, 4 excellent, 4 good, and 4 poor radiological results were observed in groups 1 and 2, respectively. intraarticular screw penetration was detected in 3 patients in group 1, while there was no articular implant penetration in group 2 (P = .001). We believe that satisfactory results can be obtained with the SBST plate technique, offering functional and clinical outcomes that are similar to those of the interfragmentary screw technique. The SBST plate technique is superior in terms of avoiding intraarticular screw penetration and related revision surgery.


Subject(s)
Acetabulum , Bone Plates , Bone Screws , Fracture Fixation, Internal , Fractures, Comminuted , Humans , Acetabulum/surgery , Acetabulum/injuries , Acetabulum/diagnostic imaging , Female , Male , Fracture Fixation, Internal/methods , Fracture Fixation, Internal/instrumentation , Middle Aged , Adult , Fractures, Comminuted/surgery , Fractures, Comminuted/diagnostic imaging , Treatment Outcome , Retrospective Studies , Fractures, Bone/surgery , Fractures, Bone/diagnostic imaging
7.
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi ; 38(5): 576-582, 2024 May 15.
Article in Chinese | MEDLINE | ID: mdl-38752244

ABSTRACT

Objective: To investigate the accuracy and effectiveness of acetabular cup placement in total hip arthroplasty (THA) after lumbar fusion applying of modified acetabular anteversion and inclination angles test system. Methods: A clinical data of 45 patients undergoing THA for osteoarthritis between January 2018 and June 2023 was retrospectively analyzed. All patients had previously received lumbar fusion. The modified acetabular anteversion and inclination angle test system was used in 26 cases (observation group) and not used in 19 cases (control group) during THA. There was no significant difference in baseline data such as gender, age, body mass index, operative side, number of lumbar fusion segments, and preoperative Harris score between the two groups ( P>0.05). The position of acetabular prosthesis, hip function (Harris score), and incidence of complications were compared between the two groups. Results: In the observation group, all acetabular cups were in the safe zone (anteversion angle, 25°-30°) during operation, and 1 acetabular cup (3.85%) was not in the safe zone after operation. In the control group, 9 acetabular cups (47.37%) were not in the safe zone. The postoperative difference between the two groups was significant ( P<0.05). There was no significant difference between intra- and post-operative acetabular inclination angles in the observation group ( P>0.05), and the postoperative acetabular inclination angle was significantly smaller in the observation group than in the control group ( P<0.05). All incisions healed by first intention and no infection occurred. All patients were followed up 6 months. There was no significant difference in Harris score between the two groups at different time point ( P>0.05), and there were significant differences between different time points in the two groups ( P<0.05). No joint dislocation occurred in the observation group during follow-up, while dislocation occurred in 2 cases and femoral impingement syndrome occurred in 1 case of the control group. There was no significant difference in the incidence of complications between the two groups ( P>0.05). Conclusion: For THA patients with lumbar fusion, the ideal placement angle of the acetabular cup can be obtained by using the modified acetabular anteversion and inclination angles test system during operation.


Subject(s)
Acetabulum , Arthroplasty, Replacement, Hip , Lumbar Vertebrae , Spinal Fusion , Humans , Arthroplasty, Replacement, Hip/methods , Acetabulum/surgery , Spinal Fusion/methods , Retrospective Studies , Male , Female , Lumbar Vertebrae/surgery , Postoperative Complications/prevention & control , Postoperative Complications/epidemiology , Postoperative Complications/etiology , Treatment Outcome , Hip Prosthesis , Middle Aged , Osteoarthritis, Hip/surgery , Aged
8.
Zhongguo Gu Shang ; 37(5): 464-9, 2024 May 25.
Article in Chinese | MEDLINE | ID: mdl-38778529

ABSTRACT

OBJECTIVE: To investigate the application effect and imaging changes of metal cushion block combined with Jumbo cup in the reconstruction of acetabular bone defect after revision of artificial hip joint. METHODS: Retrospective analysis was made on the clinical data of 83 patients who underwent revision acetabular bone defect reconstruction of the artificial hip joint in our hospital from September 2019 to October 2021. They were divided into group A and group B according to different surgical methods. There were 42 patients in group A, including 26 males and 16 females, aged from 44 to 72 years old with an average of (60.57±4.62) years, who underwent revision with metal cushion block and Jumbo cup. There were 41 patients in group B, including 22 males and 19 females, aged from 42 to 71 years old with an average of (58.74±4.25) years, who underwent revision with metal cushion block and bone cement mortar cup. The operation related indexes, Harris hip function score and visual analogue scale (VAS) of pain before operation, 1 month and 12 month after operation were compared between two groups. The results of X-ray imaging examination (hip rotation center height, acetabular abduction angle, femoral eccentricity and imaging standard qualification rate) before and 12 month after operation were evaluated, and the incidence of complications was compared between two groups. RESULTS: There was no significant difference in operation time, intraoperative bleeding volume and postoperative drainage volume between two groups (P>0.05). Both groups were followed up for 12 to 36 months with an average of (25.36±3.59) months. The scores of pain, function, deformity and Harris' total score in the two groups at 1 month after operation were higher than those before operation (P<0.05), and the scores of pain, function, deformity, joint activity and Harris' total score in two groups at 1 year after operation were higher than those before operation and 1 month after operation (P<0.05), and the above scores in group A were higher than those in group B at 1 year after operation (P<0.05). The VAS of two groups decreased successively at 1 month and 1 year after operation (P<0.05), but there was no significant difference in both groups at each time point (P>0.05). The femoral eccentricity increased in both groups at 1 year after operation (P<0.05), and group A was higher than group B (P<0.05). The height of rotation center and acetabular abduction angle decreased in both groups at 1 year after operation (P<0.05), and the height of rotation center in group A was lower than that in group B (P<0.05), but there was no significant difference in acetabular abduction angle between two groups (P>0.05). The imaging qualification rate of group A was higher than that of group B (P<0.05). There was no significant difference in the incidence of adverse reactions between two groups (P>0.05). CONCLUSION: Metal cushion block combined with Jumbo cup in the treatment of acetabular bone defects can provide the hip joint function, and restore the hip joint rotation center, femoral eccentricity and acetabular abduction angle, with obvious clinical effect.


Subject(s)
Acetabulum , Arthroplasty, Replacement, Hip , Humans , Male , Female , Middle Aged , Aged , Acetabulum/surgery , Adult , Retrospective Studies , Arthroplasty, Replacement, Hip/methods , Hip Prosthesis , Reoperation , Plastic Surgery Procedures/methods , Metals
9.
Zhongguo Gu Shang ; 37(5): 505-15, 2024 May 25.
Article in Chinese | MEDLINE | ID: mdl-38778536

ABSTRACT

OBJECTIVE: To analyze the hip joint biomechanics of the acetabular anatomical reconstruction and nonanatomical reconstruction in total hip arthroplasty (THA) for Crowe type Ⅲ developmental dysplasia of the hip (DDH) by finite element method, which provided theoretical foundation and experimental basis for the anatomical acetabular reconstruction during THA in clinical practice. METHODS: One patient with left end-stage hip arthritis secondary to Crowe type Ⅲ DDH was selected in this study, who underwent total hip arthroplasty in the orthopedic department of the First Affiliated Hospital of Bengbu Medical College in April 2020. This patient was female, 57 years old. The preoperative and postoperative three dimentional CT scan of the patient's pelvis were performed. Fourteen acetabular cup models with different anteversion, inclination and rotation center height were established in Mimics and 3-Matic software. The boundary and load conditions were set in Abaqus software. The Von Mises and stress distribution of the hip joint were calculated and observed. RESULTS: In the Crowe type Ⅲ DDH THA, if the hip rotation center was restored anatomically and the acetabular cup's inclination was set as 40°, the cup's anteversion varied from 5° to 25°, the lowest Von Mises value of acetabular cup and polyethylene liner occured in 20°anteversioin;if the hip rotation center was restored anatomically and the acetabular cup's anteversion was set as 15°, the cup's inclination varied from 35° to 55°, the lowest Von Mises value of acetabular cup and polyethylene liner occured in 35° inclination;if the acetabular cup's anteversion and inclination were set as 15°and 40°respectively, the up migration of hip rotaion center varied from 0 mm to 20 mm, the lowest Von Mises value of acetabular cup and polyethylene liner occured in 10 mm up migration. In all fourteen models, the Von Mises value of the acetabulum, acetabulum cup and polyethylene liner were lowest when the acetabular cup's anteversion and inlcination were 15°, 35° respectively, as well as the rotation center was restored anatomically. CONCLUSION: In total hip arthroplasty for Crowe type Ⅲ DDH, the anatomical restoration of hip rotation center with 15° anteversion and 35° inclination of the acetabular cup are suggested, bone graft above the acetabular cup and additional screws are recommended simultaneously to further reduce the Von Mises of hip joint.


Subject(s)
Acetabulum , Arthroplasty, Replacement, Hip , Developmental Dysplasia of the Hip , Finite Element Analysis , Humans , Arthroplasty, Replacement, Hip/methods , Female , Middle Aged , Biomechanical Phenomena , Acetabulum/surgery , Developmental Dysplasia of the Hip/surgery , Hip Joint/surgery , Hip Joint/physiopathology , Plastic Surgery Procedures/methods
10.
Article in English | MEDLINE | ID: mdl-38768051

ABSTRACT

INTRODUCTION: Diabetes mellitus (DM) is a risk factor of infection. Although DM has been associated with worse functional outcomes after acetabular fracture, literature regarding the effect of DM on surgical site infection and other early complications is lacking. METHODS: A 20-year registry from a level 1 trauma center was queried to identify 134 patients with DM and 345 nondiabetic patients with acetabular fractures. RESULTS: The diabetic patient population was older (57.2 versus 43.2; P < 0.001) and had higher average body mass index (33.6 versus 29.5; P < 0.001). Eighty-three patients with DM and 270 nondiabetics were treated surgically (62% versus 78%; P < 0.001). Diabetic patients who were younger (54.6 versus 61.4; P = 0.01) with fewer comorbidities (1.7 versus 2.2; P = 0.04) were more frequently managed surgically. On univariate analysis, patients with DM more commonly developed any early infection (28.4% versus 21%; P = 0.049) but were no more likely to develop surgical site infection, or other postoperative complications. Older patient age, length of stay, baseline pulmonary disease, and concurrent abdominal injury were independent predictors of postoperative infection other than surgical site infection. Diabetics that developed infection had more comorbidities (2.4 versus 1.5; P < 0.001) and higher Injury Severity Score (24.1 versus 15.8; P = 0.003), and were more frequently insulin-dependent (72.7% versus 41%; P = 0.01). DISCUSSION: Independent of management strategy, diabetic patients were more likely to develop an infection after acetabular fracture. Insulin dependence was associated with postoperative infection on univariate analysis. Optimal selection of surgical candidates among patients with DM may limit postoperative infections.


Subject(s)
Acetabulum , Fractures, Bone , Registries , Surgical Wound Infection , Trauma Centers , Humans , Male , Female , Middle Aged , Adult , Fractures, Bone/surgery , Fractures, Bone/epidemiology , Surgical Wound Infection/epidemiology , Surgical Wound Infection/etiology , Acetabulum/injuries , Acetabulum/surgery , Aged , Diabetes Mellitus/epidemiology , Retrospective Studies , Risk Factors , Diabetes Complications
11.
Anaesthesiol Intensive Ther ; 56(1): 54-60, 2024.
Article in English | MEDLINE | ID: mdl-38741444

ABSTRACT

INTRODUCTION: Neuraxial anaesthesia is a common choice for most hip and lower limb operations. Pain associated with positioning is often a deterrent, and the vast literature suggests different regional blocks and opioids for these patients. Patients with acetabular fractures may experience increased pain, and thus are more difficult to position for the neuraxial block. We conducted a randomized controlled pilot study to assess and compare the analgesic efficacy of ultrasound-guided suprainguinal fascia iliaca block (SFICB) versus systemic fentanyl to facilitate positioning for combined spinal epidural (CSE) anaesthesia in patients undergoing acetabular fracture surgery. MATERIAL AND METHODS: Twenty patients referred for surgical repair of acetabular fractures were randomly assigned to receive either ultrasound-guided SFICB (group B) or intravenous fentanyl (group F). Changes in visual analogue scale (VAS) scores in supine and sitting position, improvement in sitting angle (SA), positioning quality, rescue analgesic requirement, total opioid consumption, comfort VAS scores, and complications were noted to compare both groups. RESULTS: The post-intervention VAS score in the sitting position was significantly lower in group B than in group F (5.9 ± 2.1 vs. 3.5 ± 1.5, P = 0.01). Group B also had more significant improvement in SA (27.5° (20.75-36.5°), in comparison to group F (10 (5-18.75), P = 0.006). The positioning quality was better in group B, with 70% of patients achieving an optimal position compared to only 10% in group F ( P = 0.02). CONCLUSIONS: Ultrasound-guided SFICB, as compared to systemic fentanyl, provided better analgesia and helped to achieve a better and more comfortable position to perform the neuraxial block.


Subject(s)
Acetabulum , Fentanyl , Nerve Block , Patient Positioning , Ultrasonography, Interventional , Humans , Pilot Projects , Male , Female , Ultrasonography, Interventional/methods , Nerve Block/methods , Acetabulum/surgery , Adult , Middle Aged , Fentanyl/administration & dosage , Patient Positioning/methods , Analgesics, Opioid/administration & dosage , Analgesics, Opioid/therapeutic use , Fascia , Fractures, Bone/surgery , Anesthesia, Spinal/methods , Pain Measurement , Anesthesia, Epidural/methods
12.
BMC Surg ; 24(1): 157, 2024 May 16.
Article in English | MEDLINE | ID: mdl-38755649

ABSTRACT

BACKGROUND: Fractures involving the posterior acetabulum with its rich vascular and neural supply present challenges in trauma orthopedics. This study evaluates the effectiveness of 3D printing technology with the use of custom-made metal plates in the treatment of posterior wall and column acetabular fractures. METHODS: A retrospective analysis included 31 patients undergoing surgical fixation for posterior wall and column fractures of the acetabulum (16 in the 3D printing group, utilizing 3D printing for a 1:1 pelvic model and custom-made plates based on preoperative simulation; 15 in the traditional group, using conventional methods). Surgical and instrument operation times, intraoperative fluoroscopy frequency, intraoperative blood loss, fracture reduction quality, fracture healing time, preoperative and 12-month postoperative pain scores (Numeric Rating Scale, NRS), hip joint function at 6 and 12 months (Harris scores), and complications were compared. RESULTS: The surgical and instrument operation times were significantly shorter in the 3D printing group (p < 0.001). The 3D printing group exhibited significantly lower intraoperative fluoroscopy frequency and blood loss (p = 0.001 and p < 0.001, respectively). No significant differences were observed between the two groups in terms of fracture reduction quality, fracture healing time, preoperative pain scores (NRS scores), and 6-month hip joint function (Harris scores) (p > 0.05). However, at 12 months, hip joint function and pain scores were significantly better in the 3D printing group (p < 0.05). Although the incidence of complications was lower in the 3D printing group (18.8% vs. 33.3%), the difference did not reach statistical significance (p = 0.433). CONCLUSION: Combining 3D printing with individualized custom-made metal plates for acetabular posterior wall and column fractures reduces surgery and instrument time, minimizes intraoperative procedures and blood loss, enhancing long-term hip joint function recovery. CLINICAL TRIAL REGISTRATION: 12/04/2023;Trial Registration No. ChiCTR2300070438; http://www.chictr.org.cn .


Subject(s)
Acetabulum , Bone Plates , Fracture Fixation, Internal , Fractures, Bone , Printing, Three-Dimensional , Humans , Retrospective Studies , Acetabulum/surgery , Acetabulum/injuries , Male , Female , Adult , Middle Aged , Fracture Fixation, Internal/methods , Fracture Fixation, Internal/instrumentation , Treatment Outcome , Fractures, Bone/surgery , Operative Time , Young Adult , Prosthesis Design , Aged
13.
J Orthop Traumatol ; 25(1): 25, 2024 May 10.
Article in English | MEDLINE | ID: mdl-38727945

ABSTRACT

BACKGROUND: Acetabular cup positioning in total hip arthroplasty (THA) is closely related to outcomes. The literature has suggested cup parameters defined by the Lewinnek safe zone; however, the validity of such measures is in question. Several studies have raised concerns about the benefits of using the Lewinnek safe zone as a predictor of success. In this study we elected to use prospective surgeon targets as the basis for comparison to see how successful surgeons are positioning their cup using standard instruments and techniques. METHODS: A prospective, global, multicenter study was conducted. Cup positioning success was defined as a composite endpoint. Both cup inclination and version needed to be within 10° of the surgeon target to be considered a success. Radiographic analysis was conducted by a third-party reviewer. RESULTS: In 170 subjects, inclination, target versus actual, was 44.8° [standard deviation (SD 0.9°)] and 43.1° (SD 7.6°), respectively (p = 0.0029). Inclination was considered successful in 84.1% of cases. Mean version, target versus actual, was 19.4° (SD 3.9°) and 27.2° (SD 5.6°), respectively (p < 0.0001). Version was considered successful in 63.4% of cases, and combined position (inclination and version) was considered successful in 53.1%. CONCLUSION: This study shows that with traditional methods of placing the cup intraoperatively, surgeons are only accurate 53.1% of the time compared with a predicted preoperative plan. This study suggests that the inconsistency in cup positioning based on the surgeon's planned target is potentially another important variable to consider while using a mechanical guide or in freehand techniques for cup placement in THA. TRIAL REGISTRATION: This study is registered on ClinicalTrials.gov, NCT03189303.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Prosthesis , Arthroplasty, Replacement, Hip/methods , Arthroplasty, Replacement, Hip/instrumentation , Humans , Prospective Studies , Female , Male , Aged , Middle Aged , Acetabulum/surgery
14.
JBJS Case Connect ; 14(2)2024 Apr 01.
Article in English | MEDLINE | ID: mdl-38820204

ABSTRACT

CASE: A 20-year-old woman presented with a unipolar, 1.8 × 1.8-cm osteochondral defect of the left acetabulum. Osteochondral allograft transplantation was performed using a medial tibial plateau allograft resulting in excellent clinical outcomes across 4 different outcome scores and maintenance of the joint space at 4.3 years postoperatively. CONCLUSION: Although previous literature has demonstrated long-term clinical success of osteochondral allograft transplantation in knee, excellent clinical outcomes can also be obtained in the hip. Thus, osteochondral allograft transplantation may be a viable treatment option for adolescents and young adults with concomitant cartilage and subchondral bone hip defects.


Subject(s)
Acetabulum , Allografts , Bone Transplantation , Humans , Female , Acetabulum/surgery , Young Adult , Bone Transplantation/methods , Transplantation, Homologous
15.
Sci Rep ; 14(1): 12469, 2024 05 30.
Article in English | MEDLINE | ID: mdl-38816424

ABSTRACT

Poor implantation positioning of hip prostheses is considered the primary factor affecting postoperative joint wear. Cup anteversion in direct anterior approach (DAA) total hip arthroplasty (THA) is often excessive. Intraoperative fluoroscopy (IF) are effective for improving implant placement accuracy. This study aimed to analyze IF's reliability and accuracy in assessing intraoperative anteversion. Sixty-two consecutive hips underwent primary THA utilizing DAA alongside IF for cup placement. Intraoperative anteversion was measured using IF images, while postoperative CT and standard anteroposterior (AP) radiographs were used to calculate true anteversion component angles. Differences and correlations between intraoperative and true anteversions were analyzed, and intraclass correlation coefficients (ICC) determined the inter- and intra-observer reliabilities. Excellent intra- and inter-observer reliabilities were observed for all radiographic and CT methods (ICC > 0.9). Strong correlations (PCC > 0.6) existed between anteversion measured on IF image and postoperative CT and AP pelvic measurements. Intraoperative anteversion measured on IF images (16.8 ± 3.2°) was smaller than anteversion measured postoperatively on AP X-rays (21.3 ± 4.7°, P < 0.001) and CT (22.0 ± 4.9°, P < 0.001), with average differences of 4.5°and 5.3°, respectively. Under several influencing factors, the accuracy of IF in assessing cup anteversion in DAA-THA may be limited. However, this still requires large-sample experiments for verification.


Subject(s)
Acetabulum , Arthroplasty, Replacement, Hip , Hip Prosthesis , Humans , Arthroplasty, Replacement, Hip/methods , Fluoroscopy/methods , Female , Male , Middle Aged , Acetabulum/diagnostic imaging , Acetabulum/surgery , Aged , Reproducibility of Results , Tomography, X-Ray Computed/methods , Aged, 80 and over , Adult
16.
BMC Musculoskelet Disord ; 25(1): 426, 2024 May 31.
Article in English | MEDLINE | ID: mdl-38822289

ABSTRACT

BACKGROUND: The morphology of coxa profunda remains inadequately understood. However, knowledge about the characteristics of the acetabulum in coxa profunda can help to predict pelvic morphology in three dimensions based on radiographic findings, as well as help to diagnose and predict hip pathologies. Therefore, this study aimed to investigate the relationship between the morphological characteristics of the pelvis and coxa profunda. METHODS: We conducted a retrospective analysis including women who had undergone unilateral total hip arthroplasty. Only those with normal hip joint morphology on the opposite side, as evidenced by anteroposterior pelvic radiography showing a distance of ≥ 2 mm between the ilioischial line and acetabular floor, were included. Five parameters related to acetabular anteversion, thickness, and the position of the ilioischial line were measured using axial computed tomography at the central hip joint. The coxa profunda group (n = 39) and control group (n = 34) were compared. RESULTS: The mean acetabular anteversion angle was 12.5° ± 4° in the control group and 22.3° ± 5.6° in the coxa profunda group. The mean thickness from the acetabular fossa to the medial wall was 7.5 ± 1.7 mm in the control group and 3.9 ± 1.2 mm in the coxa profunda group. Furthermore, the bony region representing the ilioischial line was positioned more posteriorly in the coxa profunda group than it was in the control group. CONCLUSION: Our findings suggest that coxa profunda in women is associated with anterior acetabular dysplasia and a thin acetabulum, in contrast to previous interpretations of excessive coverage. This insight suggests a conversion of coxa profunda from a finding of pincer-type femoroacetabular impingement to a finding of acetabular dysplasia, a revelation that also draws attention to cup positioning for total hip arthroplasty.


Subject(s)
Acetabulum , Humans , Female , Acetabulum/diagnostic imaging , Acetabulum/surgery , Acetabulum/pathology , Retrospective Studies , Middle Aged , Aged , Tomography, X-Ray Computed , Arthroplasty, Replacement, Hip , Hip Joint/diagnostic imaging , Hip Joint/surgery , Hip Joint/pathology , Adult
17.
BMC Musculoskelet Disord ; 25(1): 417, 2024 May 28.
Article in English | MEDLINE | ID: mdl-38807120

ABSTRACT

OBJECTIVE: To digitally measure the fixation trajectory of anatomical plates used in the combined reduction of quadrilateral acetabular fractures via the posterior approach, and to develop anatomical plates that align with the characteristics of the pelvis in the Chinese population. METHODS: Pelvic computed tomography (CT) data from 102 adult patients were collected at the Affiliated Hospital of Zunyi Medical University. This group included 51 males and 51 females, aged between 20 and 60 years. Using Mimics software (version 21.0), a three-dimensional model of each pelvic data point was reconstructed. The fixation path for the combined reset anatomical steel plate was drawn, where the curves on the fixation path were approximated as arcs. The radius of curvature and length of these curves were measured, and an anatomical steel plate was designed to best fit the pelvic structure. RESULTS: The combined anatomical reduction plate fixation system for quadrilateral acetabular fractures using a posterior approach consisted of two parts: a locking plate and a reduction plate. The posterior wall region (r2), ischial region (r3), quadrilateral region (r4), and bending region (r5), and the total length of the reduction plate were significantly smaller in females (P < 0.05). Similarly, the posterior wall region (R3), distal posterior wall region (R4), and the total length of the locking plate were significantly smaller in females (P < 0.05). Additionally, the anterior superior iliac spine side (r1) and the total length of the T-shaped auxiliary plate were significantly smaller in females (P < 0.05). The bending angle (< A) was also significantly smaller in females (P < 0.05). CONCLUSIONS: The pelvic surface structure is irregular and varies greatly among individuals.Compared to the traditional steel plate, The combined reduction anatomical plate designed in this study demonstrated high precision and improved conformity to the anatomical structure of the pelvis.


Subject(s)
Acetabulum , Bone Plates , Fracture Fixation, Internal , Fractures, Bone , Tomography, X-Ray Computed , Humans , Female , Male , Acetabulum/diagnostic imaging , Acetabulum/injuries , Acetabulum/surgery , Adult , Middle Aged , Fracture Fixation, Internal/methods , Fracture Fixation, Internal/instrumentation , Fractures, Bone/surgery , Fractures, Bone/diagnostic imaging , Young Adult , Imaging, Three-Dimensional
18.
J Med Life ; 17(2): 188-194, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38813362

ABSTRACT

This study aimed to share our experience of a self-developed plate for acetabular fracture fixation through the presentation of clinical cases. Eight patients with complex acetabular fractures (Letournel classification) underwent surgery using a modified Stoppa approach and the novel plate design between 2021 and 2023 at the National Scientific Center for Traumatology and Orthopedics. Criteria such as the mechanism of injury, type of fracture, surgical approach, intraoperative and postoperative complications, quality of reduction, and functional and radiological results were evaluated. All patients included in the study presented complex types of acetabular fractures according to the Letournel classification. In all cases, surgical interventions were performed using a modified Stoppa approach. The assessment of reduction quality was conducted based on the radiological standards established by Matta. The reduction in quality was excellent in two patients, good in four, and satisfactory in two. One patient developed a post-traumatic false joint requiring additional surgery. The remaining patients achieved fracture healing with satisfactory Harris Hip Score (HHS) scores, indicating good overall function. The results of the self-developed plate for acetabular fracture fixation in our series were satisfactory.


Subject(s)
Acetabulum , Bone Plates , Fracture Fixation, Internal , Fractures, Bone , Humans , Acetabulum/surgery , Acetabulum/injuries , Male , Adult , Female , Fractures, Bone/surgery , Fractures, Bone/diagnostic imaging , Fracture Fixation, Internal/methods , Middle Aged , Young Adult
19.
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi ; 38(4): 455-460, 2024 Apr 15.
Article in Chinese | MEDLINE | ID: mdl-38632066

ABSTRACT

Objective: To explore the short-term effectiveness of hip revision surgery guided by artificial intelligence preoperative planning (AIHIP) system. Methods: The clinical data of 22 patients (23 hips) who were admitted between June 2019 and March 2023 and met the selection criteria were retrospectively analyzed. There were 12 males and 10 females with an average age of 69.7 years (range, 44-90 years). There were 19 hips in the first revision, 3 hips in the second revision, and 1 hip in the third revision. The causes of revision included 12 hips with prosthesis loosening, 4 hips with acetabular cup loosening, 3 hips with osteolysis, 2 hips with acetabular dislocation, 1 hip with postoperative infection, and 1 hip with prosthesis wear. There were 6 hips in stage ⅡA, 9 hips in stage ⅡB, 4 hips in stage ⅡC, 3 hips in stage ⅢA, and 1 hip in stage ⅢB according to Paprosky staging of acetabular bone defect. The replacement of prosthesis type, operation time, hospitalization stay, ground active condition, and postoperative infection, fracture, prosthesis loosening, and other adverse events were recorded. The function of the affected limb was evaluated by Harris score before operation, at 1 week and 6 months after operation, and the range of motion of the hip joint was compared before operation and at 6 months after operation. Results: The operation time was 85-510 minutes, with an average of 241.8 minutes; the hospitalization stay was 7-35 days, with an average of 15.2 days; the time of disassociation from the walker was 2-108 days, with an average of 42.2 days. All the 22 patients were followed up 8-53 months (mean, 21.7 months). No adverse events such as prosthesis loosening or infection occurred in the rest of the patients, except for postoperative hematoma of the thigh in 1 patient and dislocation of the hip in 1 hip. The matching degree of acetabular cup was completely matched in 22 hips and mismatched in 1 hip (+2), the matching rate was 95.65%. The matching degree of femoral stem was completely matched in 22 hips and generally matched in 1 hip (-1), and the matching rate was 100%. The Harris scores were 55.3±9.8 and 89.6±7.2 at 1 week and 6 months after operation, respectively, which significantly improved when compared with before operation (33.0±8.6, P<0.05), and further improved at 6 months after operation than at 1 week after operation ( P<0.05). The function of hip joint was evaluated by Harris score at 6 months after operation, and 21 hips were good and 2 hips were moderate, which could meet the needs of daily life. The range of motion of hip joint was (111.09±10.11)° at 6 months after operation, which was significantly different from (79.13±18.50)° before operation ( t=-7.269, P<0.001). Conclusion: AIHIP system can improve the accuracy of revision surgery, reduce the difficulty of surgery, and achieve good postoperative recovery and satisfactory short-term effectiveness.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Prosthesis , Joint Dislocations , Male , Female , Humans , Aged , Prosthesis Failure , Reoperation , Retrospective Studies , Artificial Intelligence , Follow-Up Studies , Treatment Outcome , Hip Joint/surgery , Acetabulum/surgery , Postoperative Complications , Joint Dislocations/surgery
20.
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi ; 38(4): 461-465, 2024 Apr 15.
Article in Chinese | MEDLINE | ID: mdl-38632067

ABSTRACT

Objective: To explore the method of accurately estimating the acetabular cup prosthesis coverage rate (hereinafter referred to as "cup coverage rate") in total hip arthroplasty (THA) based on X-ray films, and to determine the effective parameters that can be used to estimate the cup coverage rate. Methods: The three-dimensional printed pelvic models were established based on CT data of 16 healthy pelvis, and the acetabular prosthesis were implanted according to conventional THA procedure. The length and width of the uncovered area of the acetabular cup prosthesis were measured by a modified X-ray recording method with a rotating C-arm X-ray machine, and the cup coverage rate was calculated. Then the differences among the traditional anteroposterior X-ray recording method, the modified method, and actual measurement on pelvic model were statistically analyzed. The correlation between the area of the uncovered area of the prosthesis and its width and length was analyzed by using multiple linear regression analysis. Results: The cup coverage rates of traditional method, modified method, and actual measurement were 78.22%±3.36%, 86.74%±3.61%, and 89.62%±2.62%, respectively, with significant differences ( P<0.05). The results of multiple linear regression analysis showed that the width and length were positively linear with the uncovered area of the prosthesis, and the regression equation was as follows: uncovered area of the prosthesis=-21.192+0.248×width+0.140×length, and the coefficient of determination R 2=0.857, P<0.001. Conclusion: Compared with the traditional method, the modified method can more accurately evaluate the cup coverage rate during THA, and the width of the uncovered area of the prosthesis can be used as an effective reference for the cup coverage rate.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Prosthesis , Arthroplasty, Replacement, Hip/methods , Acetabulum/surgery , X-Ray Film , Tomography, X-Ray Computed/methods