1.
Environ Sci Pollut Res Int ; 31(23): 34415-34445, 2024 May.
Article in English | MEDLINE | ID: mdl-38703314

ABSTRACT

Natural ventilation potential (NVP) of a climate is a theoretical basis, and it gains importance due to the promising need for building energy conservation while conceding required thermal comfort conditions. A modified NVP analytical model is proposed by considering parameters involved in the earlier models (Yang et al., Build Environ 40:738-746, 2005; Luo et al., Build Environ 42:2289-2298, 2007). The effect of the dynamic thermal behavior of the wall/roof and building orientation on the indoor air temperature has been evaluated. The analytical model is applied to 11 major cities of India that belong to composite, hot-dry, temperate, and warm-humid climates. Five different envelope configurations are analyzed to envisage the NVP of concern climate (ED-I to ED-V). The results show that the effect of dynamic thermal response factors on the NVP is significant, and optimization of thermal response factors in addition to the U-value is mandatory. The impact of wind frequency on the selection of building orientation is substantial since it influences the total heat gained by the building envelope. Moreover, it is perceived that the optimum building orientation is independent of the climate and weather conditions. ED-II and ED-III are energy-efficient envelopes for composite, temperate, warm-humid, and hot-dry climates. The results revealed that the Mumbai climate has the highest NVP of 66% while the building is oriented in an E-W direction, and the lowest is observed for Jodhpur, i.e., 44% of the year when the building is in the NE-SW direction. The model helps the building architectural designers envisage the true NVP and assess the suitability of the building for natural ventilation.


Subject(s)
Climate , Ventilation , India , Temperature , Models, Theoretical , Air Pollution, Indoor , Cities
2.
Sci Total Environ ; 931: 173003, 2024 Jun 25.
Article in English | MEDLINE | ID: mdl-38710394

ABSTRACT

This study investigated particle and volatile organic compound (VOC) emission rates (ER) from 3D pens, which are increasingly popular in children's toys. Nine filaments and two 3D pens were evaluated using a flow tunnel, a scanning mobility particle sizer, a proton-transfer-reaction time-of-flight mass spectrometer for particles, and a thermal desorption-gas chromatography-mass spectrometer for VOCs. Results showed that the ERs varied with the pen type, filament, and brand. The particle ER was highest for acrylonitrile butadiene styrene (ABS), followed by polylactic acid (PLA) and polycaprolactone (PCL). Notably, ERs of 83 % and 33 % of ABS and PLA filaments exceeded the maximum allowable particle ER (MAER; 5 × 109 particles/min) for 3D printers but were lower than the VOC MAER (173 µg/min in the office). Different filaments emitted diverse VOCs; ABS emitted styrene and benzene, PLA emitted lactide, and PCL emitted phenol. While particle ERs from 3D pens were comparable to those from printers, the total VOC ERs from 3D pens were slightly lower. Caution is warranted when using 3D pens because of potential health risks, especially their prolonged use, proximity to the breathing zone, and usage by children. This study highlights the need for considering particles and VOCs when assessing the safety of 3D pens, emphasizing awareness of potential hazards, particularly in child-oriented settings.


Subject(s)
Volatile Organic Compounds , Volatile Organic Compounds/analysis , Environmental Monitoring/methods , Air Pollutants/analysis , Air Pollution, Indoor/analysis , Air Pollution, Indoor/statistics & numerical data , Polyesters/analysis , Printing, Three-Dimensional , Particulate Matter/analysis
3.
J Radiol Prot ; 44(2)2024 May 24.
Article in English | MEDLINE | ID: mdl-38749401

ABSTRACT

Kansas State University (KSU) Engineering Extension conducted an abridged evaluation of eight consumer grade digital radon monitors. Using the KSU secondary radon chamber, these devices were exposed to three different radon concentrations for 7 d in average household temperature and relative humidity conditions. The three different radon concentration ranges used were: 12.8 pCi L-1to 15.5 pCi L-1(473.6 Bq m-3-573.5 Bq m-3), 27.7 pCi L-1to 29.4 pCi L-1(1024.9-10 857.8 Bq m-3), and ambient room level average radon concentration of 0.6 pCi L-1(22.2 Bq m-3). The American National Standards Institute/American Academy of Radon Scientists and Technologists Performance Specifications for Instrumentation Systems Designed to Measure Radon Gas in Air (ANSI/AARST MS-PC) (ANSI/AARST MS-PC 2022Performance Specifications for Instrumentation Systems Designed to Measure Radon Gas in Air(AARST Radon Standards)) minimum performance metrics were used to evaluate the accuracy and precision of each model type for each radon concentration tested. The eight different device models performed within the 0 ± 25% requirement for the individual percent error (IPE) for radon concentrations between 27.7 pCi L-1and 29.4 pCi L-1(1024.9-10 857.8 Bq m-3). For radon concentrations between 12.8 pCi L-1and 15.5 pCi L-1(444-592 Bq m-3) seven of the eight monitors fell within the IPE requirement and for ambient room radon concentrations six of the eight monitors fell within the IPE requirement for the ANSI/AARST MS-PC minimum performance requirement (ANSI/AARST MS-PC 2022Performance Specifications for Instrumentation Systems Designed to Measure Radon Gas in Air(AARST Radon Standards)) ranges. All eight device models fell within the ± 15% ANSI/AARST MS-PC minimum performance requirement (ANSI/AARST MS-PC 2022Performance Specifications for Instrumentation Systems Designed to Measure Radon Gas in Air(AARST Radon Standards)) coefficient of variation (CV) range for radon concentrations between 12.8 pCi L-1and 15.5 pCi L-1(444-592 Bq m-3) and for radon concentrations between 27.7 pCi L-1and 29.4 pCi L-1(1024.9-10 857.8 Bq m-3). In the future, evaluating the performance of these models over time to observe their long term accuracy and precision is anticipated.


Subject(s)
Air Pollutants, Radioactive , Air Pollution, Indoor , Radiation Monitoring , Radon , Radon/analysis , Radiation Monitoring/instrumentation , Air Pollutants, Radioactive/analysis , Air Pollution, Indoor/analysis , Equipment Design
4.
J Chem Phys ; 160(17)2024 May 07.
Article in English | MEDLINE | ID: mdl-38748014

ABSTRACT

Fatty acids from cooking fumes and hypochlorous acid (HOCl) released from indoor cleaning adversely affect respiratory health, but the molecular-level mechanism remains unclear. Here, the effect of cooking oil fumes [palmitic acid (PA), oleic acid (OA), and linoleic acid (LA)] on lung model phospholipid (POPG) hydrochlorination mediated by HOCl at the air-water interface of the hanged droplets was investigated. Interfacial hydrochlorination of POPG was impeded by OA and LA, while that of POPG was facilitated by PA. The effect on POPG hydrochlorination increased with the decrease in oil fume concentration. A potential mechanism with respect to the chain length of these oil fumes, regardless of their saturation, was proposed. PA with a short carbon chain looses the POPG packing and leads to the exposure of the C=C double bonds of POPG, whereas OA and LA with a long carbon chain hinder HOCl from reaching the C=C bonds of POPG. These results for short chain and low concentration dependence suggest that the decay of oil fumes or the conversion of short-chain species by indoor interfacial chemistry might be adverse to lung health. These results provide insights into the relationship between indoor multicomponent pollutants and the respiratory system.


Subject(s)
Air Pollution, Indoor , Fatty Acids , Fatty Acids/chemistry , Hypochlorous Acid/chemistry , Cooking , Phospholipids/chemistry
5.
Environ Health Perspect ; 132(5): 55001, 2024 May.
Article in English | MEDLINE | ID: mdl-38728219

ABSTRACT

BACKGROUND: In response to the COVID-19 pandemic, new evidence-based strategies have emerged for reducing transmission of respiratory infections through management of indoor air. OBJECTIVES: This paper reviews critical advances that could reduce the burden of disease from inhaled pathogens and describes challenges in their implementation. DISCUSSION: Proven strategies include assuring sufficient ventilation, air cleaning by filtration, and air disinfection by germicidal ultraviolet (UV) light. Layered intervention strategies are needed to maximize risk reduction. Case studies demonstrate how to implement these tools while also revealing barriers to implementation. Future needs include standards designed with infection resilience and equity in mind, buildings optimized for infection resilience among other drivers, new approaches and technologies to improve ventilation, scientific consensus on the amount of ventilation needed to achieve a desired level of risk, methods for evaluating new air-cleaning technologies, studies of their long-term health effects, workforce training on ventilation systems, easier access to federal funds, demonstration projects in schools, and communication with the public about the importance of indoor air quality and actions people can take to improve it. https://doi.org/10.1289/EHP13878.


Subject(s)
Air Pollution, Indoor , COVID-19 , SARS-CoV-2 , Ventilation , COVID-19/transmission , COVID-19/prevention & control , Humans , Air Pollution, Indoor/prevention & control , Ventilation/methods , Air Microbiology , Disinfection/methods , Respiratory Tract Infections/prevention & control , Respiratory Tract Infections/transmission
6.
Environ Int ; 187: 108693, 2024 May.
Article in English | MEDLINE | ID: mdl-38705093

ABSTRACT

INTRODUCTION: Environmental exposures, such as ambient air pollution and household fuel use affect health and under-5 mortality (U5M) but there is a paucity of data in the Global South. This study examined early-life exposure to ambient particulate matter with a diameter of 2.5 µm or less (PM2.5), alongside household characteristics (including self-reported household fuel use), and their relationship with U5M in the Navrongo Health and Demographic Surveillance Site (HDSS) in northern Ghana. METHODS: We employed Satellite-based spatiotemporal models to estimate the annual average PM2.5 concentrations with the Navrongo HDSS area (1998 to 2016). Early-life exposure levels were determined by pollution estimates at birth year. Socio-demographic and household data, including cooking fuel, were gathered during routine surveillance. Cox proportional hazards models were applied to assess the link between early-life PM2.5 exposure and U5M, accounting for child, maternal, and household factors. FINDINGS: We retrospectively studied 48,352 children born between 2007 and 2017, with 1872 recorded deaths, primarily due to malaria, sepsis, and acute respiratory infection. Mean early-life PM2.5 was 39.3 µg/m3, and no significant association with U5M was observed. However, Children from households using "unclean" cooking fuels (wood, charcoal, dung, and agricultural waste) faced a 73 % higher risk of death compared to those using clean fuels (adjusted HR = 1.73; 95 % CI: 1.29, 2.33). Being born female or to mothers aged 20-34 years were linked to increased survival probabilities. INTERPRETATION: The use of "unclean" cooking fuel in the Navrongo HDSS was associated with under-5 mortality, highlighting the need to improve indoor air quality by introducing cleaner fuels.


Subject(s)
Air Pollution, Indoor , Cooking , Particulate Matter , Ghana , Humans , Child, Preschool , Infant , Female , Particulate Matter/analysis , Male , Air Pollution, Indoor/statistics & numerical data , Air Pollution, Indoor/analysis , Air Pollution, Indoor/adverse effects , Environmental Exposure/statistics & numerical data , Child Mortality , Air Pollutants/analysis , Family Characteristics , Retrospective Studies , Infant, Newborn , Air Pollution/statistics & numerical data
7.
Sci Adv ; 10(18): eadm8680, 2024 May 03.
Article in English | MEDLINE | ID: mdl-38701214

ABSTRACT

Gas and propane stoves emit nitrogen dioxide (NO2) pollution indoors, but the exposures of different U.S. demographic groups are unknown. We estimate NO2 exposure and health consequences using emissions and concentration measurements from >100 homes, a room-specific indoor air quality model, epidemiological risk parameters, and statistical sampling of housing characteristics and occupant behavior. Gas and propane stoves increase long-term NO2 exposure 4.0 parts per billion volume on average across the United States, 75% of the World Health Organization's exposure guideline. This increased exposure likely causes ~50,000 cases of current pediatric asthma from long-term NO2 exposure alone. Short-term NO2 exposure from typical gas stove use frequently exceeds both World Health Organization and U.S. Environmental Protection Agency benchmarks. People living in residences <800 ft2 in size incur four times more long-term NO2 exposure than people in residences >3000 ft2 in size; American Indian/Alaska Native and Black and Hispanic/Latino households incur 60 and 20% more NO2 exposure, respectively, than the national average.


Subject(s)
Air Pollution, Indoor , Nitrogen Dioxide , Propane , Nitrogen Dioxide/analysis , Humans , United States , Air Pollution, Indoor/analysis , Air Pollution, Indoor/adverse effects , Environmental Exposure/adverse effects , Housing , Cooking , Air Pollutants/analysis
8.
Environ Monit Assess ; 196(6): 511, 2024 May 04.
Article in English | MEDLINE | ID: mdl-38703303

ABSTRACT

Emissions of airborne pollutants from livestock buildings affect indoor air quality, the health and well-being of farmers, animals and the environment. This study aimed to evaluate the microbial count within pig sheds and its relationship with meteorological variables (temperature, relative humidity and air velocity) and particulate matter (PM10 and PM2.5) and microbial diversity. Sampling was conducted both inside and outside of two pig sheds over three seasons (summer, rainy and winter), with regular monitoring at fortnightly intervals. Results showed that the bacterial and fungal counts ranged from 0.07 to 3.98 x 103 cfu/m3 inside the sheds and 0.01 to 1.82 x 103 cfu/m3 outside. Seasonal variations were observed, with higher concentrations of particulate matter detected during the winter season, followed by summer. Climatic variables such as temperature, air velocity and relative humidity demonstrated significant impacts on the abundance of Enterobacteriaceae and fungi, while air velocity specifically influenced the presence of mesophilic bacteria and staphylococci. Importantly, no significant disparities were found between microbial counts and particulate matter levels. Staphylococcaceae emerged as the predominant bacterial family, while Aspergillus and Cladosporium spp. were the dominant fungal species within the pig sheds. The average levels of airborne bacteria and fungi in pig sheds were found to be within the recommended range, which can be attributed to the loose housing design and lower animal population on the farms.


Subject(s)
Air Microbiology , Air Pollution, Indoor , Environmental Monitoring , Particulate Matter , Animals , Particulate Matter/analysis , Swine , Air Pollution, Indoor/analysis , Air Pollution, Indoor/statistics & numerical data , Fungi , Housing, Animal , Bacteria/classification , Bacteria/isolation & purification , Seasons , Animal Husbandry , Air Pollutants/analysis
9.
Article in English | MEDLINE | ID: mdl-38791837

ABSTRACT

Air pollution poses a significant health hazard in urban areas across the globe, with India being one of the most affected countries. This paper presents environmental monitoring study conducted in Jodhpur, Rajasthan, India, to assess air quality in diverse urban environments. The study involved continuous indoor and outdoor air quality monitoring, focusing on particulate matter (PM2.5) levels, bioaerosols, and associated meteorological parameters. Laser sensor-based low-cost air quality monitors were utilized to monitor air quality and Anderson 6-stage Cascade Impactor & Petri Dish methods for bioaerosol monitoring. The study revealed that PM2.5 levels were consistently high throughout the year, highlighting the severity of air pollution in the region. Notably, indoor PM2.5 levels were often higher than outdoor levels, challenging the common notion of staying indoors during peak pollution. The study explored the spatial and temporal diversity of air pollution across various land-use patterns within the city, emphasizing the need for tailored interventions in different urban areas. Additionally, bioaerosol assessments unveiled the presence of pathogenic organisms in indoor and outdoor environments, posing health risks to residents. These findings underscore the importance of addressing particulate matter and bioaerosols in air quality management strategies. Despite the study's valuable insights, limitations, such as using low-cost air quality sensors and the need for long-term data collection, are acknowledged. Nevertheless, this research contributes to a better understanding of urban air quality dynamics and the importance of public awareness in mitigating the adverse effects of air pollution. In conclusion, this study underscores the urgent need for effective air quality management strategies in urban areas. The findings provide valuable insights for policymakers and researchers striving to address air pollution in rapidly urbanizing regions.


Subject(s)
Air Pollutants , Air Pollution , Cities , Environmental Monitoring , Particulate Matter , India , Environmental Monitoring/methods , Environmental Monitoring/instrumentation , Particulate Matter/analysis , Air Pollutants/analysis , Air Pollution/analysis , Air Pollution, Indoor/analysis , Aerosols/analysis
10.
Clin Oral Investig ; 28(5): 292, 2024 May 02.
Article in English | MEDLINE | ID: mdl-38693418

ABSTRACT

OBJECTIVES: Exposure to aerosol particles generated from tooth grinding has a negative impact on the health of dental personnel. The aim of this study was to quantitatively analyze the impact of indoor relative humidity (IRH) on the deposition of these suspended particles in a well-controlled dental environment. MATERIALS AND METHODS: In this study, a humidity control system was employed to effectively regulate and maintain indoor relative humidity (IRH). A novel computer-assisted numerical control system was developed to pre-treat the molar specimens, and accurately simulate clinical tooth grinding procedures. Each procedure was performed in triplicate, with an online real-time particle counter (ORPC; TR-8301, TongrenCo.) measuring aerosol production. All testing devices were controlled remotely. The data obtained were statistically analyzed using descriptive statistics and non-parametric tests (Kruskal-Wallis/ Dunn's post hoc test with Bonferroni correction, p < 0.05). RESULTS: The findings showed that with increasing IRH, the maximum peak concentration of aerosol particles decreased by 397% from 6.51 × 107 particles/m3 at 30% to 1.64 × 107 particles/m3 at 80%. The Kruskal-Wallis test results indicated a statistically significant effect of IRH on the aerosol increment (p < 0.05). CONCLUSIONS: Increasing the IRH level can effectively promote the deposition of aerosol particles, with a return to baseline within 15 min after reaching 60% or above. CLINICAL RELEVANCE: Our study suggested that maintaining IRH above 70% during the cleaning process, allowing natural recovery to ambient humidity levels within 15 min after cleaning, and taking basic precautions, may lead to an adequate reduction in the possible health risks of aerosol contamination.


Subject(s)
Aerosols , Air Pollution, Indoor , Humidity , Humans , Air Pollution, Indoor/analysis
11.
PLoS One ; 19(5): e0303790, 2024.
Article in English | MEDLINE | ID: mdl-38781170

ABSTRACT

We employed carbon dioxide (CO2) concentration monitoring using mobile devices to identify location-specific risks for airborne infection transmission. We lent a newly developed, portable Pocket CO2 Logger to 10 participants, to be carried at all times, for an average of 8 days. The participants recorded their location at any given time as cinema, gym, hall, home, hospital, other indoors, other outgoings, pub, restaurant, university, store, transportation, or workplace. Generalized linear mixed model was used for statistical analysis, with the objective variable set to the logarithm of CO2 concentration. Analysis was performed by assigning participant identification as the random effect and location as the fixed effect. The data were collected per participant (seven males, four females), resulting in a total of 12,253 records. Statistical analysis identified three relatively poorly ventilated locations (median values > 1,000 ppm) that contributed significantly (p < 0.0001) to CO2 concentrations: homes (1,316 ppm), halls (1,173 ppm), and gyms (1005ppm). In contrast, two locations were identified to contribute significantly (p < 0.0001) to CO2 concentrations but had relatively low average values (<1,000 ppm): workplaces (705 ppm) and stores (620 ppm). The Pocket CO2 Logger can be used to visualize airborne infectious transmission risk by location to help guide recommendation regarding infectious disease policies, such as restrictions on human flow and ventilation measures and guidelines. In the future, large-scale surveys are expected to utilize the global positioning system, Wi-Fi, or Bluetooth of an individual's smartphone to improve ease and accuracy.


Subject(s)
Carbon Dioxide , Ventilation , Humans , Carbon Dioxide/analysis , Male , Female , Tokyo/epidemiology , Adult , Air Pollution, Indoor/analysis , Environmental Monitoring/methods , COVID-19/transmission , COVID-19/epidemiology , Middle Aged
12.
Part Fibre Toxicol ; 21(1): 25, 2024 May 17.
Article in English | MEDLINE | ID: mdl-38760786

ABSTRACT

Exposure to indoor air pollutants (IAP) has increased recently, with people spending more time indoors (i.e. homes, offices, schools and transportation). Increased exposures of IAP on a healthy population are poorly understood, and those with allergic respiratory conditions even less so. The objective of this study, therefore, was to implement a well-characterised in vitro model of the human alveolar epithelial barrier (A549 + PMA differentiated THP-1 incubated with and without IL-13, IL-5 and IL-4) to determine the effects of a standardised indoor particulate (NIST 2583) on both a healthy lung model and one modelling a type-II (stimulated with IL-13, IL-5 and IL-4) inflammatory response (such as asthma).Using concentrations from the literature, and an environmentally appropriate exposure we investigated 232, 464 and 608ng/cm2 of NIST 2583 respectively. Membrane integrity (blue dextran), viability (trypan blue), genotoxicity (micronucleus (Mn) assay) and (pro-)/(anti-)inflammatory effects (IL-6, IL-8, IL-33, IL-10) were then assessed 24 h post exposure to both models. Models were exposed using a physiologically relevant aerosolisation method (VitroCell Cloud 12 exposure system).No changes in Mn frequency or membrane integrity in either model were noted when exposed to any of the tested concentrations of NIST 2583. A significant decrease (p < 0.05) in cell viability at the highest concentration was observed in the healthy model. Whilst cell viability in the "inflamed" model was decreased at the lower concentrations (significantly (p < 0.05) after 464ng/cm2). A significant reduction (p < 0.05) in IL-10 and a significant increase in IL-33 was seen after 24 h exposure to NIST 2583 (464, 608ng/cm2) in the "inflamed" model.Collectively, the results indicate the potential for IAP to cause the onset of a type II response as well as exacerbating pre-existing allergic conditions. Furthermore, the data imposes the importance of considering unhealthy individuals when investigating the potential health effects of IAP. It also highlights that even in a healthy population these particles have the potential to induce this type II response and initiate an immune response following exposure to IAP.


Subject(s)
Air Pollution, Indoor , Cell Survival , Particulate Matter , Humans , Air Pollution, Indoor/adverse effects , Particulate Matter/toxicity , Cell Survival/drug effects , A549 Cells , Cytokines/metabolism , THP-1 Cells , Alveolar Epithelial Cells/drug effects , Alveolar Epithelial Cells/metabolism , Air Pollutants/toxicity , Inflammation/chemically induced , Pulmonary Alveoli/drug effects , Pulmonary Alveoli/metabolism , Pulmonary Alveoli/pathology
13.
Sci Total Environ ; 934: 173254, 2024 Jul 15.
Article in English | MEDLINE | ID: mdl-38761924

ABSTRACT

Air pollution has been recognized as a contributing factor to sleep disorders (SD), which have been correlated with an elevated susceptibility to a variety of human diseases. Nevertheless, research has not definitively established a connection between SD and interior decorative volatile organic compounds (ID-VOCs), a significant indoor air pollutant. In this study, we employed a mouse model exposed to ID-VOCs to explore the impacts of ID-VOCs exposure on sleep patterns and the potential underlying mechanism. Of the 23 key compositions of ID-VOCs identified, aromatic hydrocarbons were found to be the most prevalent. Exposure to ID-VOCs in mice resulted in SD, characterized by prolonged wake fullness and decreased sleep during the light period. ID-VOCs exposure triggered neuroinflammatory responses in the suprachiasmatic nucleus (SCN), with microglia activation leading to the overproduction of inflammatory cytokines such as tumor necrosis factor-α (TNF-α), interleukin-1α (IL-1α), and complement component 1q (C1q), ultimately inducing A1 astrocytes. Consequently, the upregulation of branched chain amino acid transaminase 2 (BCAT2) in A1 astrocytes resulted in elevated extracellular glutamate and disruption of the wake-sleep transition mechanism, which might be the toxicological mechanism of SD caused by ID-VOCs.


Subject(s)
Air Pollutants , Sleep Wake Disorders , Volatile Organic Compounds , Animals , Mice , Air Pollutants/toxicity , Sleep Wake Disorders/chemically induced , Neuroinflammatory Diseases/chemically induced , Air Pollution, Indoor/adverse effects , Male , Signal Transduction/drug effects , Glutamic Acid/metabolism
14.
Sci Total Environ ; 934: 173183, 2024 Jul 15.
Article in English | MEDLINE | ID: mdl-38777046

ABSTRACT

Cooking with wood biomass fuels releases hazardous air pollutants, including volatile organic compounds (VOCs), that often disproportionally affect women and children. This study, conducted in Kwale and Siaya counties in Kenya, employed thermal desorption gas chromatography - mass spectrometry to analyse VOC emissions from cooking with a wood biomass three-stone open fire vs. top-lit updraft gasifier stove. In kitchens with adequate ventilation, total VOC levels increased from 35-252 µg∙m-3 before cooking to 2235-5371 µg∙m-3 during open fire cooking, whereas use of a gasifier stove resulted in reduced emissions from cooking by 48-77 % (506-2778 µg∙m-3). However, in kitchens with poor ventilation, there was only a moderate difference in total VOC levels between the two methods of cooking (9034-9378 µg∙m-3 vs. 6727-8201 µg∙m-3 for the three-stone open fire vs. gasifier stove, respectively). Using a non-target screening approach revealed significantly increased levels of VOCs, particularly benzenoids, oxygenated and heterocyclic compounds, when cooking with the traditional open fire, especially in closed kitchens, highlighting the effects of poor ventilation. Key hazardous VOCs included benzene, naphthalene, phenols and furans, suggesting potential health risks from cooking. In kitchens with good ventilation, use of the gasifier stove markedly reduced emissions of these priority toxic VOCs compared to cooking with an open fire. Thus, substituting open fires with gasifier stoves could help to improve household air quality and alleviate health risks. The study revealed that VOCs were present prior to cooking, possibly originating from previously cooked food (buildup) or the outside environment. VOC emissions were also exacerbated by reduced air flow in high humidity during rainfall, suggesting an area for further research. The findings underscore the importance of adopting cleaner cooking technologies and enhancing kitchen ventilation to mitigate the impacts of VOCs in developing countries.


Subject(s)
Air Pollutants , Air Pollution, Indoor , Cooking , Volatile Organic Compounds , Wood , Kenya , Volatile Organic Compounds/analysis , Air Pollution, Indoor/analysis , Air Pollutants/analysis , Biomass , Ventilation , Environmental Monitoring , Fires
15.
BMC Public Health ; 24(1): 1462, 2024 May 31.
Article in English | MEDLINE | ID: mdl-38822317

ABSTRACT

BACKGROUND: The effects of household air pollution on urinary incontinence (UI) symptoms and stress urinary incontinence (SUI) symptoms have not been studied. This study seeks to investigate the correlation between household air pollution and UI/SUI symptoms among middle-aged and elderly adults in India. METHODS: We employed data derived from individuals aged 45 years and older who participated in the inaugural wave (2017-2018) of the Longitudinal Aging Study in India (LASI). The assessment of household air pollution exposure and the occurrence of UI/SUI symptoms relied on self-reported data. The analytical approach adopted was cross-sectional in nature and encompassed a cohort of 64,398 participants. To explore relationships, we utilized multivariate logistic regression analysis, incorporating subgroup analysis and interaction tests. RESULTS: 1,671 (2.59%) participants reported UI symptoms and 4,862 (7.55%) participants reported SUI symptoms. Also, the prevalence of UI/SUI symptoms is much higher among middle-aged and elderly adults who use solid polluting fuels (UI: 51.23% vs. 48.77%; SUI: 54.50% vs. 45.50%). The results revealed a noteworthy correlation between household air pollution and the probability of experiencing UI/SUI symptoms, persisting even after adjusting for all conceivable confounding variables (UI: OR = 1.552, 95% CI: 1.377-1.749, p < 0.00001; SUI: OR: 1.459, 95% CI: 1.357-1.568, p < 0.00001). Moreover, significant interaction effects were discerned for age, education level, tobacco consumption, alcohol consumption, and physical activity (p for interaction < 0.05). CONCLUSIONS: The results of our study indicate that the utilization of solid fuels in the home increases the likelihood of developing urinary incontinence and stress urinary incontinence. As a result, we argue that there is an immediate need to reform the composition of cooking fuel and raise public awareness about the adverse effects of air pollution in the home.


Subject(s)
Air Pollution, Indoor , Humans , Male , Female , Middle Aged , Aged , Air Pollution, Indoor/adverse effects , India/epidemiology , Cross-Sectional Studies , Longitudinal Studies , Urinary Incontinence/epidemiology , Prevalence , Urinary Incontinence, Stress/epidemiology , Environmental Exposure/adverse effects
16.
Neurotoxicology ; 102: 114-120, 2024 May.
Article in English | MEDLINE | ID: mdl-38703899

ABSTRACT

The refinement of brain morphology extends across childhood, and exposure to environmental toxins during this period may alter typical trends. Radon is a highly common radiologic toxin with a well-established role in cancer among adults. However, effects on developmental populations are understudied in comparison. This study investigated whether home radon exposure is associated with altered brain morphology in youths. Fifty-four participants (6-14 yrs, M=10.52 yrs, 48.15% male, 89% White) completed a T1-weighted MRI and home measures of radon. We observed a significant multivariate effect of home radon concentrations, which was driven by effects on GMV. Specifically, higher home radon was associated with smaller GMV (F=6.800, p=.012, ηp2=.13). Conversely, there was a trending radon-by-age interaction on WMV, which reached significance when accounting for the chronicity of radon exposure (F=4.12, p=.049, ηp2=.09). We found that youths with above-average radon exposure showed no change in WMV with age, whereas low radon was linked with normative, age-related WMV increases. These results suggest that everyday home radon exposure may alter sensitive structural brain development, impacting developmental trajectories in both gray and white matter.


Subject(s)
Brain , Environmental Exposure , Magnetic Resonance Imaging , Radon , Humans , Male , Adolescent , Radon/adverse effects , Female , Child , Brain/diagnostic imaging , Brain/pathology , Brain/drug effects , Brain/radiation effects , Environmental Exposure/adverse effects , Air Pollution, Indoor/adverse effects
17.
Environ Pollut ; 351: 124090, 2024 Jun 15.
Article in English | MEDLINE | ID: mdl-38697249

ABSTRACT

Indoor formaldehyde poses a significant carcinogenic risk to human health, making its removal imperative. Electro-Fenton degradation has emerged as a promising technology for addressing this concern. In the electro-Fenton system, ·OH is identified as the primary active species responsible for formaldehyde removal. Hence, its generation and utilization are pivotal for the system's effectiveness and economy. Experimental and quantum chemical methods were employed to investigate the effects and mechanisms of nitrogen doping on various aspects influencing ·OH generation and utilization. Results indicate that nitrogen doping synergistically enhances the generation and utilization of ·OH, leading to an improved formaldehyde removal efficiency in nitrogen-doped cathodic systems. The dominant nitrogen type influencing ·OH generation and utilization varies across different stages. Pyridinic nitrogen facilitates H2O2 adsorption through hydrogen bonding, while pyrrolic and graphitic nitrogen contribute to formaldehyde adsorption and catalyze the conversion of H2O2 to ·OH. Both pyridinic nitrogen and pyrrolic nitrogen boost the degradation of formaldehyde by ·OH. In comparison to the unmodified system, the modified system with NAC-GF/700C as cathode exhibits remarkable improvements. The formaldehyde removal efficiency has increased twofold, and energy consumption reduced by 73.45%. Furthermore, the system demonstrates excellent cyclic stability. These advancements can be attributed to the activation temperature, which leads to the appropriate types and high content of nitrogen elements in NAC-GF/700C. The research represents an important step towards more economical and efficient electro-Fenton technology for indoor formaldehyde removal.


Subject(s)
Air Pollution, Indoor , Carbon , Electrodes , Formaldehyde , Hydrogen Peroxide , Formaldehyde/chemistry , Hydrogen Peroxide/chemistry , Carbon/chemistry , Hydroxyl Radical/chemistry , Air Pollutants/chemistry , Iron/chemistry , Adsorption
18.
Environ Sci Technol ; 58(19): 8372-8379, 2024 May 14.
Article in English | MEDLINE | ID: mdl-38691628

ABSTRACT

The development of highly efficient catalysts for formaldehyde (HCHO) oxidation is of significant interest for the improvement of indoor air quality. Up to 400 works relating to the catalytic oxidation of HCHO have been published to date; however, their analysis for collective inference through conventional literature search is still a challenging task. A machine learning (ML) framework was presented to predict catalyst performance from experimental descriptors based on an HCHO oxidation catalysts database. MnOx, CeO2, Co3O4, TiO2, FeOx, ZrO2, Al2O3, SiO2, and carbon-based catalysts with different promoters were compiled from the literature. Notably, 20 descriptors including reaction catalyst composition, reaction conditions, and catalyst physical properties were collected for data mining (2263 data points). Furthermore, the eXtreme Gradient Boosting algorithm was employed, which successfully predicted the conversion efficiency of HCHO with an R-square value of 0.81. Shapley additive analysis suggested Pt/MnO2 and Ag/Ce-Co3O4 exhibited excellent catalytic performance of HCHO oxidation based on the analysis of the entire database. Validated by experimental tests and theoretical simulations, the key descriptor identified by ML, i.e., the first promoter, was further described as metal-support interactions. This study highlights ML as a useful tool for database establishment and the catalyst rational design strategy based on the importance of analysis between experimental descriptors and the performance of complex catalytic systems.


Subject(s)
Air Pollution, Indoor , Formaldehyde , Machine Learning , Oxidation-Reduction , Formaldehyde/chemistry , Catalysis
19.
Environ Sci Technol ; 58(19): 8393-8403, 2024 May 14.
Article in English | MEDLINE | ID: mdl-38691770

ABSTRACT

The chemistry of ozone (O3) on indoor surfaces leads to secondary pollution, aggravating the air quality in indoor environments. Here, we assess the heterogeneous chemistry of gaseous O3 with glass plates after being 1 month in two different kitchens where Chinese and Western styles of cooking were applied, respectively. The uptake coefficients of O3 on the authentic glass plates were measured in the dark and under UV light irradiation typical for indoor environments (320 nm < λ < 400 nm) at different relative humidities. The gas-phase product compounds formed upon reactions of O3 with the glass plates were evaluated in real time by a proton-transfer-reaction quadrupole-interface time-of-flight mass spectrometer. We observed typical aldehydes formed by the O3 reactions with the unsaturated fatty acid constituents of cooking oils. The formation of decanal, 6-methyl-5-hepten-2-one (6-MHO), and 4-oxopentanal (4-OPA) was also observed. The employed dynamic mass balance model shows that the estimated mixing ratios of hexanal, octanal, nonanal, decanal, undecanal, 6-MHO, and 4-OPA due to O3 chemistry with authentic grime-coated kitchen glass surfaces are higher in the kitchen where Chinese food was cooked compared to that where Western food was cooked. These results show that O3 chemistry on greasy glass surfaces leads to enhanced VOC levels in indoor environments.


Subject(s)
Air Pollution, Indoor , Cooking , Glass , Ozone , Volatile Organic Compounds , Ozone/chemistry , Glass/chemistry , Air Pollutants
20.
Environ Sci Technol ; 58(19): 8326-8335, 2024 May 14.
Article in English | MEDLINE | ID: mdl-38696616

ABSTRACT

China, especially the densely populated North China region, experienced severe haze events in the past decade that concerned the public. Although the most extreme cases have been largely eliminated through recent mitigation measures, severe outdoor air pollution persists and its environmental impact needs to be understood. Severe indoor pollution draws less public attention due to the short visible distance indoors, but its public health impacts cannot be ignored. Herein, we assess the trends and impacts of severe outdoor and indoor air pollution in North China from 2014 to 2021. Our results demonstrate the uneven contribution of severe hazy days to ambient and exposure concentrations of particulate matter with an aerodynamic diameter <2.5 (PM2.5). Although severe indoor pollution contributes to indoor PM2.5 concentrations (23%) to a similar extent as severe haze contributes to ambient PM2.5 concentrations (21%), the former's contribution to premature deaths was significantly higher. Furthermore, residential emissions contributed more in the higher PM2.5 concentration range both indoors and outdoors. Notably, severe haze had greater health impacts on urban residents, while severe indoor pollution was more impactful in rural areas. Our findings suggest that, besides reducing severe haze, mitigating severe indoor pollution is an important aspect of combating air pollution, especially toward improving public health.


Subject(s)
Air Pollutants , Air Pollution, Indoor , Environmental Monitoring , Particulate Matter , China , Particulate Matter/analysis , Air Pollutants/analysis , Air Pollution , Humans