Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 9.343
Filter
1.
Sci Total Environ ; 931: 173003, 2024 Jun 25.
Article in English | MEDLINE | ID: mdl-38710394

ABSTRACT

This study investigated particle and volatile organic compound (VOC) emission rates (ER) from 3D pens, which are increasingly popular in children's toys. Nine filaments and two 3D pens were evaluated using a flow tunnel, a scanning mobility particle sizer, a proton-transfer-reaction time-of-flight mass spectrometer for particles, and a thermal desorption-gas chromatography-mass spectrometer for VOCs. Results showed that the ERs varied with the pen type, filament, and brand. The particle ER was highest for acrylonitrile butadiene styrene (ABS), followed by polylactic acid (PLA) and polycaprolactone (PCL). Notably, ERs of 83 % and 33 % of ABS and PLA filaments exceeded the maximum allowable particle ER (MAER; 5 × 109 particles/min) for 3D printers but were lower than the VOC MAER (173 µg/min in the office). Different filaments emitted diverse VOCs; ABS emitted styrene and benzene, PLA emitted lactide, and PCL emitted phenol. While particle ERs from 3D pens were comparable to those from printers, the total VOC ERs from 3D pens were slightly lower. Caution is warranted when using 3D pens because of potential health risks, especially their prolonged use, proximity to the breathing zone, and usage by children. This study highlights the need for considering particles and VOCs when assessing the safety of 3D pens, emphasizing awareness of potential hazards, particularly in child-oriented settings.


Subject(s)
Volatile Organic Compounds , Volatile Organic Compounds/analysis , Environmental Monitoring/methods , Air Pollutants/analysis , Air Pollution, Indoor/analysis , Air Pollution, Indoor/statistics & numerical data , Polyesters/analysis , Printing, Three-Dimensional , Particulate Matter/analysis
2.
J Radiol Prot ; 44(2)2024 May 24.
Article in English | MEDLINE | ID: mdl-38749401

ABSTRACT

Kansas State University (KSU) Engineering Extension conducted an abridged evaluation of eight consumer grade digital radon monitors. Using the KSU secondary radon chamber, these devices were exposed to three different radon concentrations for 7 d in average household temperature and relative humidity conditions. The three different radon concentration ranges used were: 12.8 pCi L-1to 15.5 pCi L-1(473.6 Bq m-3-573.5 Bq m-3), 27.7 pCi L-1to 29.4 pCi L-1(1024.9-10 857.8 Bq m-3), and ambient room level average radon concentration of 0.6 pCi L-1(22.2 Bq m-3). The American National Standards Institute/American Academy of Radon Scientists and Technologists Performance Specifications for Instrumentation Systems Designed to Measure Radon Gas in Air (ANSI/AARST MS-PC) (ANSI/AARST MS-PC 2022Performance Specifications for Instrumentation Systems Designed to Measure Radon Gas in Air(AARST Radon Standards)) minimum performance metrics were used to evaluate the accuracy and precision of each model type for each radon concentration tested. The eight different device models performed within the 0 ± 25% requirement for the individual percent error (IPE) for radon concentrations between 27.7 pCi L-1and 29.4 pCi L-1(1024.9-10 857.8 Bq m-3). For radon concentrations between 12.8 pCi L-1and 15.5 pCi L-1(444-592 Bq m-3) seven of the eight monitors fell within the IPE requirement and for ambient room radon concentrations six of the eight monitors fell within the IPE requirement for the ANSI/AARST MS-PC minimum performance requirement (ANSI/AARST MS-PC 2022Performance Specifications for Instrumentation Systems Designed to Measure Radon Gas in Air(AARST Radon Standards)) ranges. All eight device models fell within the ± 15% ANSI/AARST MS-PC minimum performance requirement (ANSI/AARST MS-PC 2022Performance Specifications for Instrumentation Systems Designed to Measure Radon Gas in Air(AARST Radon Standards)) coefficient of variation (CV) range for radon concentrations between 12.8 pCi L-1and 15.5 pCi L-1(444-592 Bq m-3) and for radon concentrations between 27.7 pCi L-1and 29.4 pCi L-1(1024.9-10 857.8 Bq m-3). In the future, evaluating the performance of these models over time to observe their long term accuracy and precision is anticipated.


Subject(s)
Air Pollutants, Radioactive , Air Pollution, Indoor , Radiation Monitoring , Radon , Radon/analysis , Radiation Monitoring/instrumentation , Air Pollutants, Radioactive/analysis , Air Pollution, Indoor/analysis , Equipment Design
3.
Environ Int ; 187: 108693, 2024 May.
Article in English | MEDLINE | ID: mdl-38705093

ABSTRACT

INTRODUCTION: Environmental exposures, such as ambient air pollution and household fuel use affect health and under-5 mortality (U5M) but there is a paucity of data in the Global South. This study examined early-life exposure to ambient particulate matter with a diameter of 2.5 µm or less (PM2.5), alongside household characteristics (including self-reported household fuel use), and their relationship with U5M in the Navrongo Health and Demographic Surveillance Site (HDSS) in northern Ghana. METHODS: We employed Satellite-based spatiotemporal models to estimate the annual average PM2.5 concentrations with the Navrongo HDSS area (1998 to 2016). Early-life exposure levels were determined by pollution estimates at birth year. Socio-demographic and household data, including cooking fuel, were gathered during routine surveillance. Cox proportional hazards models were applied to assess the link between early-life PM2.5 exposure and U5M, accounting for child, maternal, and household factors. FINDINGS: We retrospectively studied 48,352 children born between 2007 and 2017, with 1872 recorded deaths, primarily due to malaria, sepsis, and acute respiratory infection. Mean early-life PM2.5 was 39.3 µg/m3, and no significant association with U5M was observed. However, Children from households using "unclean" cooking fuels (wood, charcoal, dung, and agricultural waste) faced a 73 % higher risk of death compared to those using clean fuels (adjusted HR = 1.73; 95 % CI: 1.29, 2.33). Being born female or to mothers aged 20-34 years were linked to increased survival probabilities. INTERPRETATION: The use of "unclean" cooking fuel in the Navrongo HDSS was associated with under-5 mortality, highlighting the need to improve indoor air quality by introducing cleaner fuels.


Subject(s)
Air Pollution, Indoor , Cooking , Particulate Matter , Ghana , Humans , Child, Preschool , Infant , Female , Particulate Matter/analysis , Male , Air Pollution, Indoor/statistics & numerical data , Air Pollution, Indoor/analysis , Air Pollution, Indoor/adverse effects , Environmental Exposure/statistics & numerical data , Child Mortality , Air Pollutants/analysis , Family Characteristics , Retrospective Studies , Infant, Newborn , Air Pollution/statistics & numerical data
4.
Sci Adv ; 10(18): eadm8680, 2024 May 03.
Article in English | MEDLINE | ID: mdl-38701214

ABSTRACT

Gas and propane stoves emit nitrogen dioxide (NO2) pollution indoors, but the exposures of different U.S. demographic groups are unknown. We estimate NO2 exposure and health consequences using emissions and concentration measurements from >100 homes, a room-specific indoor air quality model, epidemiological risk parameters, and statistical sampling of housing characteristics and occupant behavior. Gas and propane stoves increase long-term NO2 exposure 4.0 parts per billion volume on average across the United States, 75% of the World Health Organization's exposure guideline. This increased exposure likely causes ~50,000 cases of current pediatric asthma from long-term NO2 exposure alone. Short-term NO2 exposure from typical gas stove use frequently exceeds both World Health Organization and U.S. Environmental Protection Agency benchmarks. People living in residences <800 ft2 in size incur four times more long-term NO2 exposure than people in residences >3000 ft2 in size; American Indian/Alaska Native and Black and Hispanic/Latino households incur 60 and 20% more NO2 exposure, respectively, than the national average.


Subject(s)
Air Pollution, Indoor , Nitrogen Dioxide , Propane , Nitrogen Dioxide/analysis , Humans , United States , Air Pollution, Indoor/analysis , Air Pollution, Indoor/adverse effects , Environmental Exposure/adverse effects , Housing , Cooking , Air Pollutants/analysis
5.
Environ Monit Assess ; 196(6): 511, 2024 May 04.
Article in English | MEDLINE | ID: mdl-38703303

ABSTRACT

Emissions of airborne pollutants from livestock buildings affect indoor air quality, the health and well-being of farmers, animals and the environment. This study aimed to evaluate the microbial count within pig sheds and its relationship with meteorological variables (temperature, relative humidity and air velocity) and particulate matter (PM10 and PM2.5) and microbial diversity. Sampling was conducted both inside and outside of two pig sheds over three seasons (summer, rainy and winter), with regular monitoring at fortnightly intervals. Results showed that the bacterial and fungal counts ranged from 0.07 to 3.98 x 103 cfu/m3 inside the sheds and 0.01 to 1.82 x 103 cfu/m3 outside. Seasonal variations were observed, with higher concentrations of particulate matter detected during the winter season, followed by summer. Climatic variables such as temperature, air velocity and relative humidity demonstrated significant impacts on the abundance of Enterobacteriaceae and fungi, while air velocity specifically influenced the presence of mesophilic bacteria and staphylococci. Importantly, no significant disparities were found between microbial counts and particulate matter levels. Staphylococcaceae emerged as the predominant bacterial family, while Aspergillus and Cladosporium spp. were the dominant fungal species within the pig sheds. The average levels of airborne bacteria and fungi in pig sheds were found to be within the recommended range, which can be attributed to the loose housing design and lower animal population on the farms.


Subject(s)
Air Microbiology , Air Pollution, Indoor , Environmental Monitoring , Particulate Matter , Animals , Particulate Matter/analysis , Swine , Air Pollution, Indoor/analysis , Air Pollution, Indoor/statistics & numerical data , Fungi , Housing, Animal , Bacteria/classification , Bacteria/isolation & purification , Seasons , Animal Husbandry , Air Pollutants/analysis
6.
Article in English | MEDLINE | ID: mdl-38791837

ABSTRACT

Air pollution poses a significant health hazard in urban areas across the globe, with India being one of the most affected countries. This paper presents environmental monitoring study conducted in Jodhpur, Rajasthan, India, to assess air quality in diverse urban environments. The study involved continuous indoor and outdoor air quality monitoring, focusing on particulate matter (PM2.5) levels, bioaerosols, and associated meteorological parameters. Laser sensor-based low-cost air quality monitors were utilized to monitor air quality and Anderson 6-stage Cascade Impactor & Petri Dish methods for bioaerosol monitoring. The study revealed that PM2.5 levels were consistently high throughout the year, highlighting the severity of air pollution in the region. Notably, indoor PM2.5 levels were often higher than outdoor levels, challenging the common notion of staying indoors during peak pollution. The study explored the spatial and temporal diversity of air pollution across various land-use patterns within the city, emphasizing the need for tailored interventions in different urban areas. Additionally, bioaerosol assessments unveiled the presence of pathogenic organisms in indoor and outdoor environments, posing health risks to residents. These findings underscore the importance of addressing particulate matter and bioaerosols in air quality management strategies. Despite the study's valuable insights, limitations, such as using low-cost air quality sensors and the need for long-term data collection, are acknowledged. Nevertheless, this research contributes to a better understanding of urban air quality dynamics and the importance of public awareness in mitigating the adverse effects of air pollution. In conclusion, this study underscores the urgent need for effective air quality management strategies in urban areas. The findings provide valuable insights for policymakers and researchers striving to address air pollution in rapidly urbanizing regions.


Subject(s)
Air Pollutants , Air Pollution , Cities , Environmental Monitoring , Particulate Matter , India , Environmental Monitoring/methods , Environmental Monitoring/instrumentation , Particulate Matter/analysis , Air Pollutants/analysis , Air Pollution/analysis , Air Pollution, Indoor/analysis , Aerosols/analysis
7.
Clin Oral Investig ; 28(5): 292, 2024 May 02.
Article in English | MEDLINE | ID: mdl-38693418

ABSTRACT

OBJECTIVES: Exposure to aerosol particles generated from tooth grinding has a negative impact on the health of dental personnel. The aim of this study was to quantitatively analyze the impact of indoor relative humidity (IRH) on the deposition of these suspended particles in a well-controlled dental environment. MATERIALS AND METHODS: In this study, a humidity control system was employed to effectively regulate and maintain indoor relative humidity (IRH). A novel computer-assisted numerical control system was developed to pre-treat the molar specimens, and accurately simulate clinical tooth grinding procedures. Each procedure was performed in triplicate, with an online real-time particle counter (ORPC; TR-8301, TongrenCo.) measuring aerosol production. All testing devices were controlled remotely. The data obtained were statistically analyzed using descriptive statistics and non-parametric tests (Kruskal-Wallis/ Dunn's post hoc test with Bonferroni correction, p < 0.05). RESULTS: The findings showed that with increasing IRH, the maximum peak concentration of aerosol particles decreased by 397% from 6.51 × 107 particles/m3 at 30% to 1.64 × 107 particles/m3 at 80%. The Kruskal-Wallis test results indicated a statistically significant effect of IRH on the aerosol increment (p < 0.05). CONCLUSIONS: Increasing the IRH level can effectively promote the deposition of aerosol particles, with a return to baseline within 15 min after reaching 60% or above. CLINICAL RELEVANCE: Our study suggested that maintaining IRH above 70% during the cleaning process, allowing natural recovery to ambient humidity levels within 15 min after cleaning, and taking basic precautions, may lead to an adequate reduction in the possible health risks of aerosol contamination.


Subject(s)
Aerosols , Air Pollution, Indoor , Humidity , Humans , Air Pollution, Indoor/analysis
8.
PLoS One ; 19(5): e0303790, 2024.
Article in English | MEDLINE | ID: mdl-38781170

ABSTRACT

We employed carbon dioxide (CO2) concentration monitoring using mobile devices to identify location-specific risks for airborne infection transmission. We lent a newly developed, portable Pocket CO2 Logger to 10 participants, to be carried at all times, for an average of 8 days. The participants recorded their location at any given time as cinema, gym, hall, home, hospital, other indoors, other outgoings, pub, restaurant, university, store, transportation, or workplace. Generalized linear mixed model was used for statistical analysis, with the objective variable set to the logarithm of CO2 concentration. Analysis was performed by assigning participant identification as the random effect and location as the fixed effect. The data were collected per participant (seven males, four females), resulting in a total of 12,253 records. Statistical analysis identified three relatively poorly ventilated locations (median values > 1,000 ppm) that contributed significantly (p < 0.0001) to CO2 concentrations: homes (1,316 ppm), halls (1,173 ppm), and gyms (1005ppm). In contrast, two locations were identified to contribute significantly (p < 0.0001) to CO2 concentrations but had relatively low average values (<1,000 ppm): workplaces (705 ppm) and stores (620 ppm). The Pocket CO2 Logger can be used to visualize airborne infectious transmission risk by location to help guide recommendation regarding infectious disease policies, such as restrictions on human flow and ventilation measures and guidelines. In the future, large-scale surveys are expected to utilize the global positioning system, Wi-Fi, or Bluetooth of an individual's smartphone to improve ease and accuracy.


Subject(s)
Carbon Dioxide , Ventilation , Humans , Carbon Dioxide/analysis , Male , Female , Tokyo/epidemiology , Adult , Air Pollution, Indoor/analysis , Environmental Monitoring/methods , COVID-19/transmission , COVID-19/epidemiology , Middle Aged
9.
Sci Total Environ ; 934: 173183, 2024 Jul 15.
Article in English | MEDLINE | ID: mdl-38777046

ABSTRACT

Cooking with wood biomass fuels releases hazardous air pollutants, including volatile organic compounds (VOCs), that often disproportionally affect women and children. This study, conducted in Kwale and Siaya counties in Kenya, employed thermal desorption gas chromatography - mass spectrometry to analyse VOC emissions from cooking with a wood biomass three-stone open fire vs. top-lit updraft gasifier stove. In kitchens with adequate ventilation, total VOC levels increased from 35-252 µg∙m-3 before cooking to 2235-5371 µg∙m-3 during open fire cooking, whereas use of a gasifier stove resulted in reduced emissions from cooking by 48-77 % (506-2778 µg∙m-3). However, in kitchens with poor ventilation, there was only a moderate difference in total VOC levels between the two methods of cooking (9034-9378 µg∙m-3 vs. 6727-8201 µg∙m-3 for the three-stone open fire vs. gasifier stove, respectively). Using a non-target screening approach revealed significantly increased levels of VOCs, particularly benzenoids, oxygenated and heterocyclic compounds, when cooking with the traditional open fire, especially in closed kitchens, highlighting the effects of poor ventilation. Key hazardous VOCs included benzene, naphthalene, phenols and furans, suggesting potential health risks from cooking. In kitchens with good ventilation, use of the gasifier stove markedly reduced emissions of these priority toxic VOCs compared to cooking with an open fire. Thus, substituting open fires with gasifier stoves could help to improve household air quality and alleviate health risks. The study revealed that VOCs were present prior to cooking, possibly originating from previously cooked food (buildup) or the outside environment. VOC emissions were also exacerbated by reduced air flow in high humidity during rainfall, suggesting an area for further research. The findings underscore the importance of adopting cleaner cooking technologies and enhancing kitchen ventilation to mitigate the impacts of VOCs in developing countries.


Subject(s)
Air Pollutants , Air Pollution, Indoor , Cooking , Volatile Organic Compounds , Wood , Kenya , Volatile Organic Compounds/analysis , Air Pollution, Indoor/analysis , Air Pollutants/analysis , Biomass , Ventilation , Environmental Monitoring , Fires
10.
Sci Rep ; 14(1): 10665, 2024 05 09.
Article in English | MEDLINE | ID: mdl-38724540

ABSTRACT

Bioaerosols generated during toilet flushing can contribute to the spread of airborne pathogens and cross-contamination in indoor environments. This presents an increased risk of fomite-mediated or aerosol disease transmission. This study systematically investigated the factors contributing to increased bioaerosol exposure following toilet flushing and developed an empirical model for predicting the exposure-relevant bioaerosol concentration. Air in a toilet cubicle was sampled by impaction after seeding with Clostridium difficile spores. Design of Experiments (DoE) main effects screening and full factorial design approaches were then employed to investigate the significant factors that heighten the risk of exposure to bioaerosols post-flush. Our findings reveal that the inoculated bacterial concentration (C), time elapsed after flushing (t), lateral distance (d), and mechanical ventilation (v) are significant predictors of bioaerosol concentration, with p-values < 0.05. The interaction term, C × d showed a marked increase in bioaerosol concentration up to 232 CFU/m3 at the closest proximity and highest pathogen load. The interplay of C and t (C × t) demonstrated a time-dependent attenuation of bioaerosol viability, with concentrations peaking at 241 CFU/m3 immediately post-flush and notably diminishing over time. The lateral distance and time post-flush (d × t) interaction also revealed a gradual decrease in bioaerosol concentration, highlighting the effectiveness of spatial and temporal dilution in mitigating bioaerosol exposure risks. Furthermore, there is an immediate rise in relative humidity levels post-flush, impacting the air quality in the toilet environment. This study not only advances our understanding of exposure pathways in determining bioaerosol exposure, but also offers pivotal insights for designing targeted interventions to reduce bioaerosol exposure. Recommendations include designing public toilets with antimicrobial surfaces, optimizing ventilation, and initiating timely disinfection protocols to prioritise surfaces closest to the toilet bowl during peak exposure periods, thereby promoting healthier indoor environments and safeguarding public health in high-traffic toilet settings.


Subject(s)
Aerosols , Air Microbiology , Clostridioides difficile , Toilet Facilities , Aerosols/analysis , Humans , Air Pollution, Indoor/analysis , Bathroom Equipment/microbiology
11.
Environ Sci Pollut Res Int ; 31(24): 35429-35441, 2024 May.
Article in English | MEDLINE | ID: mdl-38727973

ABSTRACT

An extensive analysis of the distribution patterns of three distinct classes of semi-volatile organic chemicals (SVOCs)-phthalates (PAEs), organophosphate flame retardants (OPFRs), and polycyclic aromatic hydrocarbons (PAHs)-across four distinct size fractions of dust (25, 50, 100, and 200 µm) was conducted. The dust samples were sourced from AC filter, covered car parking lots, households, hotels, mosques, and car floors. To generate the four fractions, ten dust samples from each microenvironment were pooled and sieved utilizing sieving apparatus with the appropriate mesh size. Selected SVOCs were quantified utilizing gas chromatography-mass spectrometry in electron impact (EI) mode. Results unveiled diverse contamination levels among dust fractions, showcasing car parking lot dust with the lowest chemical contamination, while car floor dust displayed the highest levels of PAHs and OPFRs, peaking at 28.3 µg/g and 43.2 µg/g, respectively. In contrast, mosque and household floor dust exhibited the highest concentrations of phthalates, with values of 985 µg/g and 846 µg/g, respectively. Across the analyzed microenvironments, we observed a trend where concentrations of SVOCs tended to rise as dust particles decreased in size, forming a visually striking pattern. This phenomenon was particularly pronounced in dust samples collected from car floors and parking lots. Among SVOCs, PAEs emerged as the predominant contributors with > 90% followed by OPFRs and PAHs. The high levels of OPFRs in car floor dust align logically with the fact that numerous interior components of cars are treated with OPFRs, within a compact indoor microenvironment, to comply to fire safety regulations. Furthermore, petroleum products are a major source of PAHs in the environment and all the sampled cars in the study had combustion engines. Consequently, car dust is more likely to be polluted with PAHs stemming from petroleum combustion. Although previous investigations have noted an increase in heavy metals and brominated flame retardants with decreasing dust particles, this is the first study analyzing these SVOCs in different fractions of dust from various microenvironments. However, aside from two specific microenvironments, the observed pattern of escalating SVOC concentrations with smaller dust particle sizes was not corroborated among the examined microenvironments. This divergence in concentration trends suggests the potential involvement of supplementary variables in influencing SVOC distributions within dust particles.


Subject(s)
Air Pollution, Indoor , Dust , Environmental Monitoring , Particle Size , Polycyclic Aromatic Hydrocarbons , Volatile Organic Compounds , Dust/analysis , Volatile Organic Compounds/analysis , Air Pollution, Indoor/analysis , Polycyclic Aromatic Hydrocarbons/analysis , Flame Retardants/analysis , Air Pollutants/analysis
12.
Sci Rep ; 14(1): 11858, 2024 05 24.
Article in English | MEDLINE | ID: mdl-38789478

ABSTRACT

Human occupied built environments are no longer confined to Earth. In fact, there have been humans living and working in low-Earth orbit on the International Space Station (ISS) since November 2000. With NASA's Artemis missions and the age of commercial space stations set to begin, more human-occupied spacecraft than ever will be in Earth's orbit and beyond. On Earth and in the ISS, microbes, especially fungi, can be found in dust and grow when unexpected, elevated moisture conditions occur. However, we do not yet know how indoor microbiomes in Earth-based homes and in the ISS differ due to their unique set of environmental conditions. Here we show that bacterial and fungal communities are different in dust collected from vacuum bags on Earth and the ISS, with Earth-based homes being more diverse (465 fungal OTUs and 237 bacterial ASVs) compared to the ISS (102 fungal OTUs and 102 bacterial ASVs). When dust from these locations were exposed to varying equilibrium relative humidity conditions (ERH), there were also significant fungal community composition changes as ERH and time elevated increased (Bray Curtis: R2 = 0.35, P = 0.001). These findings can inform future spacecraft design to promote healthy indoor microbiomes that support crew health, spacecraft integrity, and planetary protection.


Subject(s)
Air Pollution, Indoor , Dust , Fungi , Microbiota , Spacecraft , Dust/analysis , Fungi/isolation & purification , Fungi/classification , Humans , Air Pollution, Indoor/analysis , Built Environment , Bacteria/classification , Bacteria/isolation & purification , Bacteria/genetics , Air Microbiology , Earth, Planet , Humidity
13.
Sensors (Basel) ; 24(10)2024 May 13.
Article in English | MEDLINE | ID: mdl-38793956

ABSTRACT

This work presents a retrospective analysis of indoor CO2 measurements obtained with a mobile robot in an educational building after the COVID-19 lockdown (May 2021), at a time when public activities resumed with mandatory local pandemic restrictions. The robot-based CO2 measurement system was assessed as an alternative to the deployment of a net of sensors in a building in the pandemic period, in which there was a global stock outage of CO2 sensors. The analysis of the obtained measurements confirms that a mobile system can be used to obtain interpretable information on the CO2 levels inside the rooms of a building during a pandemic outbreak.


Subject(s)
Air Pollution, Indoor , COVID-19 , Carbon Dioxide , Pandemics , Robotics , COVID-19/epidemiology , Carbon Dioxide/analysis , Humans , Retrospective Studies , Robotics/methods , Air Pollution, Indoor/analysis , SARS-CoV-2/isolation & purification , Environmental Monitoring/methods
14.
Sensors (Basel) ; 24(10)2024 May 07.
Article in English | MEDLINE | ID: mdl-38793821

ABSTRACT

Radon is a naturally occurring noble radioactive gas that poses significant health risks, particularly lung cancer, due to its colorless, odorless, and tasteless nature, which makes detection challenging without formal testing. It is found in soil, rock, and water, and it infiltrates indoor environments, necessitating regulatory standards and guidelines from organizations such as the Environmental Protection Agency, the World Health Organization, and the Occupational Health and Safety Agency to mitigate exposure. In this paper, we present various methods and instruments for radon assessment in occupational and environmental settings. Discussion on long- and short-term monitoring, including grab sampling, radon dosimetry, and continuous real-time monitoring, is provided. The comparative analysis of detection techniques-active versus passive-is highlighted from real-time data and long-term exposure assessment, including advances in sensor technology, data processing, and public awareness, to improve radon exposure evaluation techniques.


Subject(s)
Occupational Exposure , Radon , Radon/analysis , Humans , Occupational Exposure/analysis , Occupational Exposure/prevention & control , Radiation Monitoring/methods , Radiation Monitoring/instrumentation , Air Pollution, Indoor/analysis , Air Pollutants, Radioactive/analysis , Environmental Exposure/analysis
15.
Environ Int ; 187: 108673, 2024 May.
Article in English | MEDLINE | ID: mdl-38663235

ABSTRACT

Metro systems play a crucial role in public transportation worldwide. Given that metro stations are unique built environments with a significant volume of daily commuters, ensuring a satisfactory air quality in these spaces becomes paramount. This study involved measurements of indoor air quality (IAQ), staff satisfaction, particulate matter (PM) chemical composition, and heavy metal health risks at a typical metro station in Tianjin over two seasons. Although the air exchange rate was sufficient to maintain a CO2 concentration less than 1000 ppm, the proportion of staff reporting no sick-building symptoms decreased from 83 % in spring to 25 % in winter. An average mass concentration of PM with an aerodynamic diameter smaller than 2.5 µm (PM2.5) of 68.0 ± 42.2 µg/m3 and an average PM1 mass concentration of 51.8 ± 33.3 µg/m3 were observed on the platform in winter. PM2.5 contained more metal in winter than in spring. PM2.5 in winter contained more metal in winter than in spring. With a lower relative humidity in winter, the coefficient of friction between railway wheels and rails increased, thus increasing particle emission. The carcinogenic risk of Cr on the platform was unacceptable. Moreover, the health risks induced by Ba should be investigated. The findings indicate that PM control at metro stationss, particularly on platforms in winter, should be emphasized.


Subject(s)
Air Pollution, Indoor , Particulate Matter , Railroads , Sick Building Syndrome , China , Air Pollution, Indoor/analysis , Air Pollution, Indoor/statistics & numerical data , Humans , Particulate Matter/analysis , Seasons , Air Pollutants/analysis , Metals, Heavy/analysis , Environmental Monitoring
16.
Environ Sci Technol ; 58(18): 7958-7967, 2024 May 07.
Article in English | MEDLINE | ID: mdl-38656997

ABSTRACT

Because humans spend about one-third of their time asleep in their bedrooms and are themselves emission sources of volatile organic compounds (VOCs), it is important to specifically characterize the composition of the bedroom air that they experience during sleep. This work uses real-time indoor and outdoor measurements of volatile organic compounds (VOCs) to examine concentration enhancements in bedroom air during sleep and to calculate VOC emission rates associated with sleeping occupants. Gaseous VOCs were measured with proton-transfer reaction time-of-flight mass spectrometry during a multiweek residential monitoring campaign under normal occupancy conditions. Results indicate high emissions of nearly 100 VOCs and other species in the bedroom during sleeping periods as compared to the levels in other rooms of the same residence. Air change rates for the bedroom and, correspondingly, emission rates of sleeping-associated VOCs were determined for two bounding conditions: (1) air exchange between the bedroom and outdoors only and (2) air exchange between the bedroom and other indoor spaces only (as represented by measurements in the kitchen). VOCs from skin oil oxidation and personal care products were present, revealing that many emission pathways can be important occupant-associated emission factors affecting bedroom air composition in addition to direct emissions from building materials and furnishings.


Subject(s)
Air Pollution, Indoor , Sleep , Volatile Organic Compounds , Volatile Organic Compounds/analysis , Air Pollution, Indoor/analysis , Humans , Environmental Monitoring , Housing , Air Pollutants/analysis
17.
Environ Int ; 186: 108641, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38621323

ABSTRACT

People generally spend most of their time indoors, making a comprehensive evaluation of air pollution characteristics in various indoor microenvironments of great significance for accurate exposure estimation. In this study, field measurements were conducted in Kunming City, Southwest China, using real-time PM2.5 sensors to characterize indoor PM2.5 in ten different microenvironments including three restaurants, four public places, and three household settings. Results showed that the daily average PM2.5 concentrations in restaurants, public spaces, and households were 78.4 ± 24.3, 20.1 ± 6.6, and 18.0 ± 4.3 µg/m3, respectively. The highest levels of indoor PM2.5 in restaurants were owing to strong internal emissions from cooking activities. Dynamic changes showed that indoor PM2.5 levels increased during business time in restaurants and public places, and cooking time in residential kitchens. Compared with public places, restaurants generally exhibit more rapid increases in indoor PM2.5 due to cooking activities, which can elevate indoor PM2.5 to high levels (5.1 times higher than the baseline) in a short time. Furthermore, indoor PM2.5 in restaurants were dominated by internal emissions, while outdoor penetration contributed mostly to indoor PM2.5 in public places and household settings. Results from this study revealed large variations in indoor PM2.5 in different microenvironments, and suggested site-specific measures for indoor PM2.5 pollution alleviation.


Subject(s)
Air Pollutants , Air Pollution, Indoor , Environmental Monitoring , Particulate Matter , Air Pollution, Indoor/analysis , Air Pollution, Indoor/statistics & numerical data , Particulate Matter/analysis , China , Air Pollutants/analysis , Humans , Cities , Cooking , Restaurants/statistics & numerical data , Particle Size
18.
Sci Total Environ ; 927: 172132, 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38569952

ABSTRACT

This study investigated the occurrence and distribution of per- and polyfluoroalkyl substances (PFASs) in house dust samples from six regions across four continents. PFASs were detected in all indoor dust samples, with total median concentrations ranging from 17.3 to 197 ng/g. Among the thirty-one PFAS analytes, eight compounds, including emerging PFASs, exhibited high detection frequencies in house dust from all six locations. The levels of PFASs varied by region, with higher concentrations found in Adelaide (Australia), Tianjin (China), and Carbondale (United States, U.S.). Moreover, PFAS composition profiles also differed among regions. Dust from Australia and the U.S. contained high levels of 6:2 fluorotelomer phosphate ester (6:2 diPAP), while perfluorooctanoic acid (PFOA) and perfluorooctane sulfonic acid (PFOS) were predominant in other regions. Furthermore, our results indicate that socioeconomic factors impact PFAS levels. The assessment of human exposure through dust ingestion and dermal contact indicates that toddlers may experience higher exposure levels than adults. However, the hazard quotients of PFASs for both toddlers and adults were below one, indicating significant health risks are unlikely. Our study highlights the widespread occurrence of PFASs in global indoor dust and the need for continued monitoring and regulation of these chemicals.


Subject(s)
Air Pollution, Indoor , Dust , Environmental Exposure , Environmental Monitoring , Fluorocarbons , Dust/analysis , Humans , Air Pollution, Indoor/analysis , Air Pollution, Indoor/statistics & numerical data , Fluorocarbons/analysis , Environmental Exposure/statistics & numerical data , Environmental Exposure/analysis , Air Pollutants/analysis , Caprylates/analysis , Alkanesulfonic Acids/analysis , Australia , China
19.
J Radiol Prot ; 44(2)2024 Apr 18.
Article in English | MEDLINE | ID: mdl-38632901

ABSTRACT

The high radon concentrations measured in the indoor air of groundwater facilities and the prevalence of the problem have been known for several years. Unlike in other workplaces, in groundwater plants, radon is released into the air from the water treatment processes. During the measurements of this study, the average radon concentrations varied from 500 to 8800 Bq m-3. In addition, the indoor air of the treatment plants is filtered and there are no significant internal aerosol sources. However, only a few published studies on groundwater plants have investigated the properties of the radon progeny aerosol, such as the equilibrium factor (F) or the size distribution of the aerosol, which are important for assessing the dose received by workers. Moreover, the International Commission on Radiological Protection has not provided generic aerosol parameter values for dose assessment in groundwater treatment facilities. In this study, radon and radon progeny measurements were carried out at three groundwater plants. The results indicate surprisingly high unattached fractions (fp= 0.27-0.58), suggesting a low aerosol concentration in indoor air. The correspondingFvalues were 0.09-0.42, well below those measured in previous studies. Based on a comparison of the effective dose rate calculations, either the determination of thefpor, with certain limitations, the measurement of radon is recommended. Dose rate calculation based on the potential alpha energy concentration alone proved unreliable.


Subject(s)
Air Pollutants, Radioactive , Air Pollution, Indoor , Groundwater , Radiation Monitoring , Radon , Humans , Radon Daughters/analysis , Air Pollutants, Radioactive/analysis , Radon/analysis , Aerosols , Radiation Monitoring/methods , Air Pollution, Indoor/analysis
20.
Chemosphere ; 355: 141866, 2024 May.
Article in English | MEDLINE | ID: mdl-38565375

ABSTRACT

Biochar-based materials for air treatment have gained significant attention for removing health-detrimental volatile organic compounds (VOCs) and particulate matter (PM) in indoor air settings. However, high turnaround time, multiple pretreatment processes involved, and high pore size and low surface area (>10 µm, <100 m2 g-1) of lignocellulosic feedstocks demand alternative biochar feedstock material. Considering this, we designed a simple first-of-its-kind indoor air scrubbing material using diatoms-enriched microalgae biochar. In the present study, the microalgae were cultivated on waste anaerobic digestate (biogas slurry) and were pyrolyzed at three different temperatures: 300 °C (BC300), 500 °C (BC500), and 700 °C (BC700). The BC500 and BC700 showed the highest removal efficiencies (99 %) for total volatile organic carbons (TVOCs) and formaldehyde (HCHO) at concentrations of 1.22 mg m-3 HCHO and 8.57 mg m-3 TVOC compared to 50% efficiency obtained with commercially available surgical, cloth, and N95 masks. The biochar obtained showed a high Brunauer-Emmett-Teller (BET) surface area of 238 m2 g-1 (BC500) and 480 m2 g-1 (BC700) and an average pore size of 9-11 nm due to the mesoporous characteristic of diatom frustules. The comparatively poor performance of BC300 was due to lower surface area (150 m2 g-1) arising from incomplete organic removal, as evidenced by FESEM-EDX and FTIR. The high removal efficiencies in BC500 and BC700 were also attributed to the presence of reactive functional groups such as -OH and R-NH2. Concurrently, the average particulate matter (PM10, PM2.5, and PM1) removal efficiency for BC500 and BC 700 ranged between 66 and 82.69 %. The PM removal performance of BC500 and BC700 was lower (15-20%) than commercially available masks. Overall, the present study highlights the importance of diatoms (reactive Si) present inside the pores of microalgal biochar for enhanced removal of PM, TVOCs, and HCHO at temperatures above 500 °C. This complete approach signifies a step towards establishing a self-sustainable and circular process characterized by minimal waste generation for indoor air treatment.


Subject(s)
Air Pollutants , Air Pollution, Indoor , Charcoal , Microalgae , Volatile Organic Compounds , Particulate Matter/analysis , Volatile Organic Compounds/analysis , Air Pollution, Indoor/analysis , Formaldehyde , Air Pollutants/analysis , Environmental Monitoring
SELECTION OF CITATIONS
SEARCH DETAIL
...