Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 12.472
Filter
1.
Article in English | MEDLINE | ID: mdl-38839349

ABSTRACT

T-tubes and airway stents are commonly used but have limited effectiveness and frequent complications. A 50-year-old male patient presented with severe tracheal stenosis, affecting an 8.7 cm length of the airway. We employed an innovative approach known as external suspension fixation of tracheal stent using robotic assistance. This method involves surgically attaching the stent to the exterior of the trachea to provide support and stabilize the softened or collapsed tracheal segments. We designed a C-shaped nickel-titanium alloy exterior stent and successfully fixed it using robotic assistance. This intervention effectively restored tracheal function and led to a favorable postoperative recovery. The technique does not affect tracheal membrane function or airway mucociliary clearance. It could potentially be considered as a new option for treating long-segment benign tracheal softening or collapse.


Subject(s)
Nickel , Prosthesis Design , Robotic Surgical Procedures , Stents , Titanium , Tracheal Stenosis , Humans , Male , Middle Aged , Tracheal Stenosis/surgery , Tracheal Stenosis/diagnostic imaging , Tracheal Stenosis/etiology , Tracheal Stenosis/physiopathology , Treatment Outcome , Alloys
2.
J Long Term Eff Med Implants ; 34(4): 83-94, 2024.
Article in English | MEDLINE | ID: mdl-38842236

ABSTRACT

Powder-mixed electrical discharge machining (PMEDM) enhances the effectiveness of the electric discharge machining process. It has been used on the Mg alloy AZ91D to address biodegradation concerns in implants. By combining nano-conductive powder particles with the dielectric fluid, PMEDM creates a functional surface. Process parameters like pulse on time, pulse off time, peak current, and powder concentration are examined to optimize material removal rate (MRR), surface roughness (SR), and white layer thickness (WLT). The optimization of input parameters was completed using the Taguchi L9 technique and further analyzed using ANOVA technique that illustrates Ton and pulse-off time as more significant process parameters for powder mixed electric discharge machining as compared with electric potential and peak current. The optimal surface roughness value is found to be 2.215 µm at 3A pulse current and 15 µs Toff time which suggest the material to be suitable for implants.


Subject(s)
Absorbable Implants , Alloys , Magnesium , Surface Properties , Magnesium/chemistry , Materials Testing , Powders
3.
J Appl Biomater Funct Mater ; 22: 22808000231214359, 2024.
Article in English | MEDLINE | ID: mdl-38702952

ABSTRACT

Exploring high strength materials with a higher concentration of reinforcements in the alloy proves to be a challenging task. This research has explored magnesium-based composites (AZ31B alloy) with tungsten carbide reinforcements, enhancing strength for medical joint replacements via league championship optimisation. The primary objective is to enhance medical joint replacement biomaterials employing magnesium-based composites, emphasising the AZ31B alloy with tungsten carbide reinforcements. The stir casting method is utilised in the manufacture of magnesium matrix composites (MMCs), including varied percentages of tungsten carbide (WC). The mechanical characteristics, such as micro-hardness, tensile strength, and yield strength, have been assessed and compared with computational simulations. The wear studies have been carried out to analyse the tribological behaviour of the composites. Additionally, this study investigates the prediction of stress and the distribution of forces inside bone and joint structures, therefore offering significant contributions to the field of biomedical research. This research contemplates the use of magnesium-based MMCs for the discovery of biomaterials suitable for medical joint replacement. The study focuses on the magnesium alloy AZ31B, with particles ranging in size from 40 to 60 microns used as the matrix material. Moreover, the outcomes have revealed that when combined with MMCs based on AZ31B-magnesium matrix, the WC particle emerges as highly effective reinforcements for the fabrication of lightweight, high-strength biomedical composites. This study uses the league championship optimisation (LCO) approach to identify critical variables impacting the synthesis of Mg MMCs from an AZ31B-based magnesium alloy. The scanning electron microscopy (SEM) images are meticulously analysed to depict the dispersion of WC particulates and the interface among the magnesium (Mg) matrix and WC reinforcement. The SEM analysis has explored the mechanisms underlying particle pull-out, the characteristics of inter-particle zones, and the influence of the AZ31B matrix on the enhancement of the mechanical characteristics of the composites. The application of finite element analysis (FEA) is being used in order to make predictions regarding the distribution of stress and the interactions of forces within the model of the hip joint. This study has compared the physico-mechanical and tribological characteristics of WC to distinct combinations of 0%, 5%, 10% and 15%, and its impact on the performance improvements. SEM analysis has confirmed the findings' improved strength and hardness, particularly when 10%-15% of WC was incorporated. Following the incorporation of 10% of WC particles within Mg-alloy matrix, the outcomes of the study has exhibited enhanced strength and hardness, which furthermore has been evident by utilising SEM analysis. Using ANSYS, structural deformation and stress levels are predicted, along with strength characteristics such as additional hardness of 71 HRC, tensile strength of 140-150 MPa, and yield strength closer to 100-110 MPa. The simulations yield significant insights into the behaviour of the joint under various loading conditions, thus enhancing the study's significance in biomedical environments.


Subject(s)
Alloys , Magnesium , Materials Testing , Alloys/chemistry , Magnesium/chemistry , Tungsten Compounds/chemistry , Biocompatible Materials/chemistry , Humans , Tensile Strength , Hip Joint
4.
BMC Surg ; 24(1): 169, 2024 May 29.
Article in English | MEDLINE | ID: mdl-38811965

ABSTRACT

BACKGROUND: Whether polyetheretherketone (PEEK) rods have potential as an alternative to titanium alloy (Ti) rods in transforaminal lumbar interbody fusion (TLIF) remains unclear, especially in cases with insufficient anterior support due to the absence of a cage. The purpose of this study was to investigate biomechanical differences between PEEK rods and Ti rods in TLIF with and without a cage. METHODS: An intact L1-L5 lumbar finite element model was constructed and validated. Accordingly, four TLIF models were developed: (1) Ti rods with a cage; (2) PEEK rods with a cage; (3) Ti rods without a cage; and (4) PEEK rods without a cage. The biomechanical properties were then compared among the four TLIF constructs. RESULTS: With or without a cage, no obvious differences were found in the effect of PEEK rods and Ti rods on the range of motion, adjacent disc stress, and adjacent facet joint force. Compared to Ti rods, PEEK rods increase the average bone graft strain (270.8-6055.2 µE vs. 319.0-8751.6 µE). Moreover, PEEK rods reduced the stresses on the screw-rod system (23.1-96.0 MPa vs. 7.2-48.4 MPa) but increased the stresses on the cage (4.6-35.2 MPa vs. 5.6-40.9 MPa) and endplates (5.7-32.5 MPa vs. 6.6-37.6 MPa). CONCLUSIONS: Regardless of whether a cage was used for TLIF, PEEK rods theoretically have the potential to serve as an alternative to Ti rods because they may provide certain stability, increase the bone graft strain, and reduce the posterior instrumentation stress, which might promote bony fusion and decrease instrumentation failure.


Subject(s)
Alloys , Benzophenones , Finite Element Analysis , Ketones , Lumbar Vertebrae , Polyethylene Glycols , Polymers , Spinal Fusion , Titanium , Humans , Spinal Fusion/instrumentation , Spinal Fusion/methods , Biomechanical Phenomena , Lumbar Vertebrae/surgery , Range of Motion, Articular , Biocompatible Materials
5.
Mikrochim Acta ; 191(6): 330, 2024 05 14.
Article in English | MEDLINE | ID: mdl-38744738

ABSTRACT

In view of a large number of people infected with Helicobacter pylori (H. pylori) with great harm followed, there is an urgent need to develop a non-invasive, easy-to-operate, and rapid detection method, and to identify effective sterilization strategies. In this study, highly specific nanoprobes with nanozyme activity, Ag@Pt nanoparticles (NPs) with the antibody, were utilized as a novel lateral flow immunoassay (LFIA). The optical label (Ag@Pt NPs) was enhanced by the introduction of the chromogenic substrate 3,3',5,5'-tetramethylbenzidine (TMB) and compared with a gold nanoparticles (Au NPs) optical label. Under the optimal condition, Ag@Pt-LFIA and TMB-enhanced Ag@Pt-LFIA for H. pylori were successfully established, two of which were over twofold and 100-fold more sensitive than conventional visual Au NP-based LFIA, respectively. Furthermore, Ag@Pt NPs with the antibody irradiated with NIR laser (808 nm) at a power intensity of 550 mW/cm2 for 5 min exhibited a remarkable antibacterial effect. The nanoprobes could close to bacteria through effective interactions between antibodies and bacteria, thereby benefiting photothermal sterilization. Overall, Ag@Pt NPs provide promising applications in pathogen detection and therapeutic applications.


Subject(s)
Alloys , Helicobacter pylori , Metal Nanoparticles , Platinum , Silver , Helicobacter pylori/radiation effects , Helicobacter pylori/drug effects , Silver/chemistry , Metal Nanoparticles/chemistry , Platinum/chemistry , Alloys/chemistry , Anti-Bacterial Agents/pharmacology , Anti-Bacterial Agents/chemistry , Immunoassay/methods , Benzidines/chemistry , Gold/chemistry , Humans , Sterilization/methods , Limit of Detection
6.
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi ; 38(5): 535-541, 2024 May 15.
Article in Chinese | MEDLINE | ID: mdl-38752238

ABSTRACT

Objective: To evaluate the effectiveness of using titanium alloy trabecular bone three-dimensional (3D) printed artificial vertebral body in treating cervical ossification of the posterior longitudinal ligament (OPLL). Methods: A retrospective analysis was conducted on clinical data from 45 patients with cervical OPLL admitted between September 2019 and August 2021 and meeting the selection criteria. All patients underwent anterior cervical corpectomy and decompression, interbody bone graft fusion, and titanium plate internal fixation. During operation, 21 patients in the study group received titanium alloy trabecular bone 3D printed artificial vertebral bodies, while 24 patients in the control group received titanium cages. There was no significant difference in baseline data such as gender, age, disease duration, affected segments, or preoperative pain visual analogue scale (VAS) score, Japanese Orthopaedic Association (JOA) score, Neck Disability Index (NDI), vertebral height, and C 2-7Cobb angle ( P>0.05). Operation time, intraoperative blood loss, and occurrence of complications were recorded for both groups. Preoperatively and at 3 and 12 months postoperatively, the functionality and symptom relief were assessed using JOA scores, VAS scores, and NDI evaluations. The vertebral height and C 2-7 Cobb angle were detected by imaging examinations and the implant subsidence and intervertebral fusion were observed. Results: The operation time and incidence of complications were significantly lower in the study group than in the control group ( P<0.05), while the difference in intraoperative blood loss between the two groups was not significant ( P>0.05). All patients were followed up 12-18 months, with the follow-up time of (14.28±4.34) months in the study group and (15.23±3.54) months in the control group, showing no significant difference ( t=0.809, P=0.423). The JOA score, VAS score, and NDI of the two groups improved after operation, and further improved at 12 months compared to 3 months, with significant differences ( P<0.05). At each time point, the study group exhibited significantly higher JOA scores and improvement rate compared to the control group ( P<0.05); but there was no significantly difference in VAS score and NDI between the two groups ( P>0.05). Imaging re-examination showed that the vertebral height and C 2-7Cobb angle of the two groups significantly increased at 3 and 12 months after operation ( P<0.05), and there was no significant difference between 3 and 12 months after operation ( P>0.05). At each time point, the vertebral height and C 2-7Cobb angle of the study group were significantly higher than those of the control group ( P<0.05), and the implant subsidence rate was significantly lower than that of the control group ( P<0.05). However, there was no significant difference in intervertebral fusion rate between the two groups ( P>0.05). Conclusion: Compared to traditional titanium cages, the use of titanium alloy trabecular bone 3D-printed artificial vertebral bodies for treating cervical OPLL results in shorter operative time, fewer postoperative complications, and lower implant subsidence rates, making it superior in vertebral reconstruction.


Subject(s)
Alloys , Cervical Vertebrae , Ossification of Posterior Longitudinal Ligament , Printing, Three-Dimensional , Spinal Fusion , Titanium , Humans , Ossification of Posterior Longitudinal Ligament/surgery , Cervical Vertebrae/surgery , Retrospective Studies , Spinal Fusion/methods , Spinal Fusion/instrumentation , Decompression, Surgical/methods , Cancellous Bone , Treatment Outcome , Vertebral Body/surgery , Female , Male , Bone Plates , Middle Aged
7.
ACS Appl Bio Mater ; 7(5): 3096-3109, 2024 May 20.
Article in English | MEDLINE | ID: mdl-38764432

ABSTRACT

Wire arc additive manufacturing (WAAM) holds promise for producing medium to large industrial components. Application of WAAM in the manufacturing of biomedical materials has not yet been evaluated. The current study addresses two key research questions: first, the suitability of the WAAMed Ti6Al4V alloy for biomedical applications, and second, the effect of Ti6Al4V's constituents (α and ß phases) on the cell viability. The WAAMed Ti6Al4V alloy was fabricated (as-deposited: AD) using a metal inert gas (MIG)-based wire arc system using an in-house designed shielding chamber filled with argon. Subsequently, samples were subjected to solution treatment (950 °C for 1 h), followed by aging at 480 °C (T1), 530 °C (T2), and 580 °C (T3) for 8 h and subsequent normalization to ambient conditions. Microstructural analysis revealed ∼45.45% of α'-Ti colonies in the as-deposited samples, reducing to 23.26% postaging at 580 °C (T3). The α-lath thickness and interstitial oxygen content in the sample were observed to be proportional to the aging temperature, peaking at 580 °C (T3). Remarkably, during tribocorrosion analysis in simulated body fluid, the 580 °C-aged T3 sample displayed the lowest corrosion rate (7.9 µm/year) and the highest coefficient of friction (CoF) at 0.58, showing the effect of increasing oxygen content in the alloy matrix. Cell studies showed significant growth at 530 and 580 °C by day 7, correlated with higher oxygen content, while other samples had declining cell density. Additionally, optimal metallurgical property ranges were identified to enhance the Ti6Al4V alloy's biocompatibility, providing crucial insights for biomedical implant development.


Subject(s)
Alloys , Biocompatible Materials , Cell Survival , Hot Temperature , Materials Testing , Titanium , Titanium/chemistry , Alloys/chemistry , Cell Survival/drug effects , Biocompatible Materials/chemistry , Biocompatible Materials/pharmacology , Animals , Particle Size , Mice , Surface Properties
8.
PLoS One ; 19(5): e0302729, 2024.
Article in English | MEDLINE | ID: mdl-38743667

ABSTRACT

The constitutive model and modulus parameter equivalence of shape memory alloy composites (SMAC) serve as the foundation for the structural dynamic modeling of composite materials, which has a direct impact on the dynamic characteristics and modeling accuracy of SMAC. This article proposes a homogenization method for SMA composites considering interfacial phases, models the interface stress transfer of three-phase cylinders physically, and derives the axial and shear stresses of SMA fiber phase, interfacial phase, and matrix phase mathematically. The homogenization method and stress expression were then used to determine the macroscopic effective modulus of SMAC as well as the stress characteristics of the fiber phase and interface phase of SMA. The findings demonstrate the significance of volume fraction and tensile pre-strain in stress transfer between the fiber phase and interface phase at high temperatures. The maximum axial stress in the fiber phase is 705.05 MPa when the SMA is fully austenitic and the pre-strain increases to 5%. At 10% volume fraction of SMA, the fiber phase's maximum axial stress can reach 1000 MPa. Ultimately, an experimental verification of the theoretical calculation method's accuracy for the effective modulus of SMAC lays the groundwork for the dynamic modeling of SMAC structures.


Subject(s)
Alloys , Stress, Mechanical , Tensile Strength , Alloys/chemistry , Materials Testing/methods , Elastic Modulus , Smart Materials/chemistry , Models, Theoretical
9.
BMC Oral Health ; 24(1): 564, 2024 May 14.
Article in English | MEDLINE | ID: mdl-38745154

ABSTRACT

BACKGROUND: Alterations in the mechanical properties of the materials utilized in orthodontic appliances could affect the working properties of the appliances, thereby affecting clinical progress and outcome. Numerous studies have confirmed the correlation between alloy corrosion and raised surface roughness, which has a direct impact on the working characteristics of orthodontic archwires. METHODS: Thirty nickel-titanium (NiTi) orthodontic archwires were utilized in this study. Patients were randomly selected and allocated into three groups according to the randomization plan; (The control group): subjects practiced regular oral hygiene; (The fluoride group): subjects used fluoride for intensive prophylaxis; (The chlorhexidine group): subjects used chlorhexidine. Representative samples were evaluated by SEM, and then SEM images with high resolution were examined using Image J software to determine the surface roughness and obtain the results for further statistical analysis. RESULTS: Our findings indicated a significant difference was found between the three groups regarding the anterior and posterior parts between the control and the two other groups and a non-significant difference between NaF and CHX groups. Overall, the p-value for group comparisons was 0.000 for both parts, indicating a highly significant difference especially between the control and NaF groups. CONCLUSION: Mouthwashes containing sodium fluoride demonstrated more significant surface alterations than the control and CHX groups and should be prescribed in accordance with orthodontic materials to reduce side effects.


Subject(s)
Alloys , Chlorhexidine , Dental Alloys , Microscopy, Electron, Scanning , Nickel , Orthodontic Wires , Sodium Fluoride , Surface Properties , Humans , Sodium Fluoride/therapeutic use , Chlorhexidine/therapeutic use , Corrosion , Dental Alloys/chemistry , Nickel/chemistry , Titanium/chemistry , Cariostatic Agents/therapeutic use , Cariostatic Agents/chemistry , Male , Female , Young Adult , Mouthwashes/therapeutic use , Mouthwashes/chemistry , Image Processing, Computer-Assisted/methods , Adolescent , Adult , Oral Hygiene
10.
J Biomed Mater Res B Appl Biomater ; 112(6): e35415, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38773744

ABSTRACT

This study reports the synthesis and characterization of hydroxyapatite (HA)-based bio-composites reinforced with varying amounts (by weight, 1-15 wt.%) of bio-medium entropy alloy (BioMEA) for load-bearing implant applications. BioMEA powders consisting of Ti, Nb, Zr, and Mo were mechanically alloyed for 100 h and subsequently added to HA using powder metallurgy techniques. To show the effect of BioMEA, the microstructure, density, and mechanical tests have been conducted and the synthesized BioMEA was characterized by scanning electron microscope (SEM), x-ray diffractometer (XRD), and Fourier-transform infrared spectroscopy (FTIR) analysis. In addition, in vitro degradation behavior and bioactivity analyses of bio-composites have been conducted. XRD analysis revealed the formation of BioMEA after 20 h of mechanical alloying. The highest density value of 2.47 g/cm3 was found in 15 wt.% BioMEA-reinforced bio-composite. The addition of BioMEA reinforcement led to a significant increase in hardness and tensile strength values, with the highest values observed at 15 wt.% reinforcement. Compression tests demonstrated a significant increase in compressive strength and deformation capability of the bio-composites with the highest values observed at 15 wt.% BioMEA addition. The highest toughness of 7.68 kJ/m2 was measured in 10 wt.% MEA-reinforced bio-composites. The produced bio-composite materials have an elastic modulus between 3.5-5.5 GPa, which may provide a solution to the stress shielding problems caused by the high elastic modulus of metallic implant materials. The most severe degradation occurred in 15 wt.% MEA-reinforced bio-composites, and the effect of degradation caused a decrease in Ca and an increase in Ti-Ni-Zr-Mo in all bio-composites. These findings suggest that HA/BioMEA bio-composites have the potential to be developed as advanced biomaterials with moderate mechanical and biological properties for load-bearing implant applications.


Subject(s)
Alloys , Durapatite , Materials Testing , Titanium , Zirconium , Zirconium/chemistry , Durapatite/chemistry , Alloys/chemistry , Titanium/chemistry , Entropy , Niobium/chemistry , Biocompatible Materials/chemistry
11.
Sci Rep ; 14(1): 11748, 2024 05 23.
Article in English | MEDLINE | ID: mdl-38783056

ABSTRACT

The present study aimed to evaluate the outcomes of percutaneous treatment of aortic coarctation using self-expandable uncovered Nitinol stents. We conducted a retrospective clinical data review of all patients with aortic coarctation and treated with self-expandable uncovered Nitinol stents at our institution between 2009 and 2019. The gradient pressure across the coarctation site was measured using aortography. Follow-up echocardiography and computed tomography angiography were performed to assess possible stent complications. A total of 127 stents were successfully implanted in 125 patients (64.8% males) with a mean age of 35.36 ± 11.9 years. The gradient across the coarctation site decreased significantly from 67.48 ± 14.79 to 5.04 ± 3.01 mmHg (P < 0.001) after self-expandable stent implantation. Systolic blood pressure (SBP) decreased significantly from 175.53 ± 15.99 to 147.22 ± 12.83 mmHg (P < 0.001) after self-expandable stenting. There were no major technical or clinical complications, including balloon rupture, aneurysmal formation, infection, secondary stent migration, thrombosis, death during the procedure, and in-hospital mortality. On a mean follow-up of 48 ± 23.6 months (12-120 months), the gradient [from 59.43 ± 15.42 to 3.72 ± 1.38 mmHg (P < 0.001)] and SBP [from 175.53 ± 15.99 to 127.99 ± 7.82 mmHg (P < 0.001)] decreased significantly. There was no mortality, aneurysmal formation in the stent site, dislocation, or aortic re-stenosis requiring intervention during mid-term follow-up. Treatment of aortic coarctation using a self-expandable uncovered nitinol stent is safe and effective with promising mid-term outcomes.


Subject(s)
Aortic Coarctation , Humans , Aortic Coarctation/surgery , Aortic Coarctation/therapy , Male , Female , Adult , Retrospective Studies , Treatment Outcome , Middle Aged , Self Expandable Metallic Stents/adverse effects , Alloys , Stents/adverse effects , Computed Tomography Angiography , Young Adult , Follow-Up Studies
12.
ACS Sens ; 9(5): 2395-2401, 2024 May 24.
Article in English | MEDLINE | ID: mdl-38722860

ABSTRACT

PdNi alloy thin films demonstrate exceptional hydrogen sensing performance and exhibit significant potential for application in surface acoustic wave (SAW) hydrogen sensors. However, the long-term stability of SAW H2 sensors utilizing PdNi films as catalysts experiences a substantial decrease during operation. In this paper, X-ray photoelectron spectroscopy (XPS) is employed to investigate the failure mechanisms of PdNi thin films under operational conditions. The XPS analysis reveals that the formation of PdO species on PdNi thin films plays a crucial role in the failure of hydrogen sensing. Additionally, density functional theory (DFT) calculations indicate that hydrogen atoms encounter a diffusion energy barrier during the penetration process from the PdNiOx surface to the subsurface region. The identification of PdNi film failure mechanisms through XPS and DFT offers valuable insights into the development of gas sensors with enhanced long-term stability. Guided by these mechanisms, we propose a method to restore the hydrogen sensing response time and magnitude to a certain extent by reducing the partially oxidized surface of the PdNi alloy under a hydrogen atmosphere at 70 °C, thereby restoring Pd to its metallic state with zero valence.


Subject(s)
Hydrogen , Nickel , Oxidation-Reduction , Palladium , Sound , Hydrogen/chemistry , Palladium/chemistry , Nickel/chemistry , Surface Properties , Density Functional Theory , Photoelectron Spectroscopy , Alloys/chemistry
13.
Acta Biomater ; 181: 469-482, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38723926

ABSTRACT

Medium-entropy alloys (MEAs) typically exhibit outstanding mechanical properties, but their high Young's modulus results in restricted clinical applications. Mismatched Young's modulus between implant materials and human bones can lead to "stress shielding" effects, leading to implant failure. In contrast, ß-Ti alloys demonstrate a lower Young's modulus compared to MEAs, albeit with lower strength. In the present study, based on the bimodal grain size distribution (BGSD) strategy, a series of high-performance TiZrNbTa/Ti composites are obtained by combining TiZrNbTa MEA powders with nano-scale grain sizes and commercially pure Ti (CP-Ti) powders with micro-scale grain sizes. Concurrently, Zr, Nb, and Ta that are ß-Ti stabilizer elements diffuse into Ti, inducing an isomorphous transformation in Ti from the high Young's modulus α-Ti phase to the low Young's modulus ß-Ti phase at room temperature, optimizing the mechanical biocompatibility. The TiZrNbTa/ß-Ti composite demonstrates a yield strength of 1490 ± 83 MPa, ductility of 20.7 % ± 2.9 %, and Young's modulus of 87.6 ± 1.6 GPa. Notably, the yield strength of the TiZrNbTa/ß-Ti composite surpasses that of sintered CP-Ti by 2.6-fold, and its ductility outperforms TiZrNbTa MEA by 2.3-fold. The Young's modulus of the TiZrNbTa/ß-Ti composite is reduced by 28 % and 36 % compared to sintered CP-Ti and TiZrNbTa MEA, respectively. Additionally, it demonstrates superior biocompatibility compared to CP-Ti plate, sintered CP-Ti, and TiZrNbTa MEA. With a good combination of mechanical properties and biocompatibility, the TiZrNbTa/ß-Ti composite exhibits significant potential for clinical applications as metallic biomaterials. STATEMENT OF SIGNIFICANCE: This work combines TiZrNbTa MEA with nano-grains and commercially pure Ti with micro-grains to fabricate a TiZrNbTa/ß-Ti composite with bimodal grain-size, which achieves a yield strength of 1490 ± 83 MPa and a ductility of 20.7 % ± 2.9 %. Adhering to the ISO 10993-5 standard, the TiZrNbTa/ß-Ti composite qualifies as a non-cytotoxic material, achieving a Class 0 cytotoxicity rating and demonstrating outstanding biocompatibility akin to commercially pure Ti. Drawing on element diffusion, Zr, Nb, and Ta serve not only as solvent atoms to achieve solid-solution strengthening but also as stabilizers for the transformation of the ß-Ti crystal structure. This work offers a novel avenue for designing advanced biomedical Ti alloys with elevated strength and plasticity alongside a reduced Young's modulus.


Subject(s)
Alloys , Biocompatible Materials , Materials Testing , Titanium , Titanium/chemistry , Titanium/pharmacology , Alloys/chemistry , Alloys/pharmacology , Biocompatible Materials/chemistry , Biocompatible Materials/pharmacology , Animals , Elastic Modulus , Humans , Niobium/chemistry , Niobium/pharmacology , Zirconium/chemistry , Zirconium/pharmacology , Phase Transition , Mice
14.
Int J Mol Sci ; 25(10)2024 May 13.
Article in English | MEDLINE | ID: mdl-38791360

ABSTRACT

Overly fast corrosion degradation of biodegradable magnesium alloys has been a major problem over the last several years. The development of protective coatings by using biocompatible, biodegradable, and non-toxic material such as chitosan ensures a reduction in the rate of corrosion of Mg alloys in simulated body fluids. In this study, chitosan/TiO2 nanocomposite coating was used for the first time to hinder the corrosion rate of Mg19Zn1Ca alloy in Hank's solution. The main goal of this research is to investigate and explain the corrosion degradation mechanism of Mg19Zn1Ca alloy coated by nanocomposite chitosan-based coating. The chemical composition, structural analyses, and corrosion tests were used to evaluate the protective properties of the chitosan/TiO2 coating deposited on the Mg19Zn1Ca substrate. The chitosan/TiO2 coating slows down the corrosion rate of the magnesium alloy by more than threefold (3.6 times). The interaction of TiO2 (NPs) with the hydroxy and amine groups present in the chitosan molecule cause their uniform distribution in the chitosan matrix. The chitosan/TiO2 coating limits the contact of the substrate with Hank's solution.


Subject(s)
Alloys , Chitosan , Coated Materials, Biocompatible , Magnesium , Titanium , Chitosan/chemistry , Titanium/chemistry , Alloys/chemistry , Corrosion , Magnesium/chemistry , Coated Materials, Biocompatible/chemistry , Zinc/chemistry , Materials Testing , Calcium/chemistry , Nanocomposites/chemistry
15.
Sci Rep ; 14(1): 12243, 2024 05 28.
Article in English | MEDLINE | ID: mdl-38806607

ABSTRACT

Stress shielding and aseptic loosening are complications of short stem total hip arthroplasty, which may lead to hardware failure. Stems with increased porosity toward the distal end were discovered to be effective in reducing stress shielding, however, there is a lack of research on optimized porous distribution in stem's coating. This study aimed to optimize the distribution of the coefficient of friction of a metaphyseal femoral stem, aiming for reducing stress shielding in the proximal area. A finite element analysis model of an implanted, titanium alloy short-tapered wedge stem featuring a porous coating made of titanium was designed to simulate a static structural analysis of the femoral stem's behavior under axial loading in Analysis System Mechanical Software. For computational feasibility, 500 combinations of coefficients of friction were randomly sampled. Increased strains in proximal femur were found in 8.4% of the models, which had decreased coefficients of friction in middle medial areas of porous coating and increased in lateral proximal and lateral and medial distal areas. This study reported the importance of the interface between bone and middle medial and distal lateral areas of the porous coating in influencing the biomechanical behavior of the proximal femur, and potentially reducing stress shielding.


Subject(s)
Arthroplasty, Replacement, Hip , Femur , Finite Element Analysis , Friction , Hip Prosthesis , Titanium , Humans , Femur/physiology , Porosity , Arthroplasty, Replacement, Hip/methods , Titanium/chemistry , Stress, Mechanical , Prosthesis Design , Coated Materials, Biocompatible/chemistry , Biomechanical Phenomena , Alloys/chemistry
16.
ACS Appl Mater Interfaces ; 16(19): 24274-24294, 2024 May 15.
Article in English | MEDLINE | ID: mdl-38699930

ABSTRACT

In the field of bone tissue engineering, recently developed Zn alloy scaffolds are considered potential candidates for biodegradable implants for bone regeneration and defect reconstruction. However, the clinical success of these alloys is limited due to their insufficient surface bioactivities. Further, the higher concentration of Zn2+ produced during degradation promotes antibacterial activity, but deteriorates osteogenic properties. This study fabricated an Azadirachta indica (neem)-assisted brushite-hydroxyapatite (HAp) coating on the recently developed Zn-2Cu-0.5Mg alloy to tackle the above dilemma. The microstructure, degradation behavior, antibacterial activity, and hemocompatibility, along with in vitro and in vivo cytocompatibility of the coated alloys, are systematically investigated. Microstructural analysis reveals flower-like morphology with uniformly grown flakes for neem-assisted deposition. The neem-assisted deposition significantly improves the adhesion strength from 12.7 to 18.8 MPa, enhancing the mechanical integrity. The potentiodynamic polarization study shows that the neem-assisted deposition decreases the degradation rate, with the lowest degradation rate of 0.027 mm/yr for the ZHN2 sample. In addition, the biomineralization process shows the apatite formation on the deposited coating after 21 days of immersion. In vitro cytotoxicity assay exhibits the maximum cell viability of 117% for neem-assisted coated alloy in 30% extract after 5d and the improved cytocompatibility which is due to the controlled release of Zn2+ ions. Meanwhile, neem-assisted coated alloy increases the ZOI by 32 and 24% for Gram-positive and Gram-negative bacteria, respectively. Acceptable hemolysis (<5%) and anticoagulation parameters demonstrate a promising hemocompatibility of the coated alloy. In vivo implantation illustrates a slight inflammatory response and vascularization after 2 weeks of subcutaneous implantation, and neo-bone formation in the defect areas of the rat femur. Micro-CT and histology studies demonstrate better osseointegration with satisfactory biosafety response for the neem-assisted coated alloy as compared to that without neem-assisted deposition. Hence, this neem-assisted brushite-Hap coating strategy elucidates a new perspective on the surface modification of biodegradable implants for the treatment of bone defects.


Subject(s)
Alloys , Calcium Phosphates , Coated Materials, Biocompatible , Zinc , Alloys/chemistry , Alloys/pharmacology , Zinc/chemistry , Zinc/pharmacology , Animals , Coated Materials, Biocompatible/chemistry , Coated Materials, Biocompatible/pharmacology , Calcium Phosphates/chemistry , Calcium Phosphates/pharmacology , Anti-Bacterial Agents/chemistry , Anti-Bacterial Agents/pharmacology , Humans , Durapatite/chemistry , Durapatite/pharmacology , Materials Testing , Mice , Green Chemistry Technology , Absorbable Implants
17.
ACS Appl Mater Interfaces ; 16(19): 24321-24340, 2024 May 15.
Article in English | MEDLINE | ID: mdl-38700914

ABSTRACT

In current clinical practices related to orthopedics, dental, and cardiovascular surgeries, a number of biomaterial coatings, such as hydroxyapatite (HAp), diamond-like carbon (DLC), have been used in combination with metallic substrates (stainless steel, Ti6Al4V alloy, etc.). Although SiBCN coatings are widely explored in material science for diverse applications, their potential remains largely unexplored for biomedical applications. With this motivation, the present work reports the development of SiBxCyNzOm coatings on a Ti6Al4V substrate, employing a reactive radiofrequency (RF) magnetron sputtering technique. Three different coating compositions (Si0.27B0.10C0.31N0.07O0.24, Si0.23B0.06C0.21N0.22O0.27, and Si0.20B0.05C0.19N0.20O0.35) were obtained using a Si2BC2N target and varying nitrogen flow rates. The hydrophilic properties of the as-synthesized coatings were rationalized in terms of an increase in the number of oxygen-containing functional groups (OH and NO) on the surface, as probed using XPS and FTIR analyses. Furthermore, the cellular monoculture of SVEC4-10 endothelial cells and L929 fibroblasts established good cytocompatibility. More importantly, the coculture system of SVEC4-10 and L929, in the absence of growth factors, demonstrated clear cellular phenotypical changes, with extensive sprouting leading to tube-like morphologies on the coating surfaces, when stimulated using a customized cell stimulator (StimuCell) with 1.15 V/cm direct current (DC) electric field strength for 1 h. In addition, the hemocompatibility assessment using human blood samples revealed clinically acceptable hemolysis, less erythrocyte adhesion, shorter plasma recalcification, and reduced risk for thrombosis on the SiBxCyNzOm coatings, when compared to uncoated Ti6Al4V. Taken together, the present study unambiguously establishes excellent cytocompatibility, hemocompatibility, and defines the preangiogenic properties of SiBxCyNzOm bioceramic coatings for potential biomedical applications.


Subject(s)
Alloys , Coated Materials, Biocompatible , Materials Testing , Titanium , Coated Materials, Biocompatible/chemistry , Coated Materials, Biocompatible/pharmacology , Alloys/chemistry , Alloys/pharmacology , Titanium/chemistry , Titanium/pharmacology , Humans , Animals , Mice , Endothelial Cells/drug effects , Endothelial Cells/cytology , Cell Line , Surface Properties , Fibroblasts/drug effects , Fibroblasts/cytology , Neovascularization, Physiologic/drug effects
18.
J Orthop Surg Res ; 19(1): 304, 2024 May 20.
Article in English | MEDLINE | ID: mdl-38769535

ABSTRACT

BACKGROUND: Periprosthetic joint infection is a serious complication following joint replacement. The development of bacterial biofilms bestows antibiotic resistance and restricts treatment via implant retention surgery. Electromagnetic induction heating is a novel technique for antibacterial treatment of metallic surfaces that has demonstrated in-vitro efficacy. Previous studies have always employed stationary, non-portable devices. This study aims to assess the in-vitro efficacy of induction-heating disinfection of metallic surfaces using a new Portable Disinfection System based on Induction Heating. METHODS: Mature biofilms of three bacterial species: S. epidermidis ATCC 35,984, S. aureus ATCC 25,923, E. coli ATCC 25,922, were grown on 18 × 2 mm cylindrical coupons of Titanium-Aluminium-Vanadium (Ti6Al4V) or Cobalt-chromium-molybdenum (CoCrMo) alloys. Study intervention was induction-heating of the coupon surface up to 70ºC for 210s, performed using the Portable Disinfection System (PDSIH). Temperature was monitored using thermographic imaging. For each bacterial strain and each metallic alloy, experiments and controls were conducted in triplicate. Bacterial load was quantified through scraping and drop plate techniques. Data were evaluated using non-parametric Mann-Whitney U test for 2 group comparison. Statistical significance was fixed at p ≤ 0.05. RESULTS: All bacterial strains showed a statistically significant reduction of CFU per surface area in both materials. Bacterial load reduction amounted to 0.507 and 0.602 Log10 CFU/mL for S. aureus on Ti6Al4V and CoCrMo respectively, 5.937 and 3.500 Log10 CFU/mL for E. coli, and 1.222 and 0.372 Log10 CFU/mL for S. epidermidis. CONCLUSIONS: Electromagnetic induction heating using PDSIH is efficacious to reduce mature biofilms of S aureus, E coli and S epidermidis growing on metallic surfaces of Ti6Al4V and CoCrMo alloys.


Subject(s)
Alloys , Biofilms , Disinfection , Escherichia coli , Prosthesis-Related Infections , Staphylococcus aureus , Titanium , Biofilms/drug effects , Disinfection/methods , Escherichia coli/growth & development , Staphylococcus aureus/drug effects , Prosthesis-Related Infections/prevention & control , Prosthesis-Related Infections/microbiology , Staphylococcus epidermidis/drug effects , Joint Prosthesis/microbiology , Arthroplasty, Replacement/instrumentation , Arthroplasty, Replacement/methods , Heating/instrumentation , Heating/methods , Humans , Electromagnetic Phenomena , Vitallium
19.
Biomater Adv ; 161: 213899, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38772133

ABSTRACT

Large bone defects, particularly those exceeding the critical size, present a clinical challenge due to the limited regenerative capacity of bone tissue. Traditional treatments like autografts and allografts are constrained by donor availability, immune rejection, and mechanical performance. This study aimed to develop an effective solution by designing gradient gyroid scaffolds with titania (TiO2) surface modification for the repair of large segmental bone defects. The scaffolds were engineered to balance mechanical strength with the necessary internal space to promote new bone formation and nutrient exchange. A gradient design of the scaffold was optimized through Finite Element Analysis (FEA) and Computational Fluid Dynamics (CFD) simulations to enhance fluid flow and cell adhesion. In vivo studies in rabbits demonstrated that the G@TiO2 scaffold, featuring a gradient structure and TiO2 surface modification, exhibited superior healing capabilities compared to the homogeneous structure and TiO2 surface modification (H@TiO2) and gradient structure (G) scaffolds. At 12 weeks post-operation, in a bone defect representing nearly 30 % of the total length of the radius, the implantation of the G@TiO2 scaffold achieved a 27 % bone volume to tissue volume (BV/TV) ratio, demonstrating excellent osseointegration. The TiO2 surface modification provided photothermal antibacterial effects, enhancing the scaffold's biocompatibility and potential for infection prevention. These findings suggest that the gradient gyroid scaffold with TiO2 surface modification is a promising candidate for treating large segmental bone defects, offering a combination of mechanical strength, bioactivity, and infection resistance.


Subject(s)
Alloys , Surface Properties , Tissue Scaffolds , Titanium , Titanium/chemistry , Animals , Rabbits , Tissue Scaffolds/chemistry , Alloys/chemistry , Bone Regeneration/drug effects , Osseointegration/drug effects , Bone and Bones , Tissue Engineering/methods , Finite Element Analysis , Biocompatible Materials/chemistry , Biocompatible Materials/pharmacology
20.
Biomater Adv ; 161: 213882, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38710121

ABSTRACT

Metallic lattice scaffolds are designed to mimic the architecture and mechanical properties of bone tissue and their surface compatibility is of primary importance. This study presents a novel surface modification protocol for metallic lattice scaffolds printed from a superelastic Ti-Zr-Nb alloy. This protocol consists of dynamic chemical etching (DCE) followed by silver nanoparticles (AgNP) decoration. DCE, using an 1HF + 3HNO3 + 12H2O23% based solution, was used to remove partially-fused particles from the surfaces of different as-built lattice structures (rhombic dodecahedron, sheet gyroid, and Voronoi polyhedra). Subsequently, an antibacterial coating was synthesized on the surface of the scaffolds by a controlled (20 min at a fixed volume flowrate of 500 mL/min) pumping of the functionalization solutions (NaBH4 (2 mg/mL) and AgNO3 (1 mg/mL)) through the porous structures. Following these treatments, the scaffolds' surfaces were found to be densely populated with Ag nanoparticles and their agglomerates, and manifested an excellent antibacterial effect (Ag ion release rate of 4-8 ppm) suppressing the growth of both E. coli and B. subtilis bacteria up to 99 %. The scaffold extracts showed no cytotoxicity and did not affect cell proliferation, indicating their safety for subsequent use as implants. A cytocompatibility assessment using MG-63 spheroids demonstrated good attachment, spreading, and active migration of cells on the scaffold surface (over 96 % of living cells), confirming their biotolerance. These findings suggest the promise of this surface modification approach for developing superelastic Ti-Zr-Nb scaffolds with superior antibacterial properties and biocompatibility, making them highly suitable for bone implant applications.


Subject(s)
Anti-Bacterial Agents , Metal Nanoparticles , Silver , Surface Properties , Tissue Scaffolds , Titanium , Zirconium , Silver/chemistry , Silver/pharmacology , Metal Nanoparticles/chemistry , Titanium/chemistry , Titanium/pharmacology , Anti-Bacterial Agents/pharmacology , Anti-Bacterial Agents/chemistry , Tissue Scaffolds/chemistry , Zirconium/chemistry , Zirconium/pharmacology , Humans , Niobium/chemistry , Niobium/pharmacology , Lasers , Escherichia coli/drug effects , Alloys/chemistry , Alloys/pharmacology , Bacillus subtilis/drug effects , Powders , Materials Testing , Cell Proliferation/drug effects
SELECTION OF CITATIONS
SEARCH DETAIL
...