Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 5.478
Filter
1.
Scand Cardiovasc J ; 58(1): 2347295, 2024 Dec.
Article in English | MEDLINE | ID: mdl-38706409

ABSTRACT

Objectives. This study investigated the influence of higher pressure protection with a small diameter balloon of side branch (SB) on bifurcation lesions. Background. Of the different coronary stent implantation techniques, the modified jailed balloon technique has become a viable option for bifurcation lesions. However, there was no detailed study on the relationship between the balloon inflation pressure of the main vessel (MV) and SB. Methods. In this study, we collected information of patients who underwent percutaneous coronary intervention (PCI) for bifurcated lesions between March 2019 and December 2022. They were divided into two groups according to the operation way: active jailed balloon technique (A-JBT) group and jailed wire technique (JWT) group. Results. A total of 216 patients were enrolled. The A-JBT group had a larger SB stenosis diameter (1.53 ± 0.69 vs. 0.95 ± 0.52, p < .001), the lower degree of stenosis (44.34 ± 18.30 vs. 63.69 ± 17.34, p < .001) compared to the JWT group. However, the JWT group had a higher incidence of SB occlusion (18.0% vs. 1.9%, p < .001) compared to the A-JBT group. Nevertheless, the success rate for both groups was 100%. Conclusions. This novel high inflation pressure and small diameter balloon approach we propose has significant advantages. There is a lower rate of SB occlusion and SB dissection, which is more cost-effective and provides better clinical outcomes for the patient. This method should be considered in the future for treating bifurcation lesions.


Subject(s)
Angioplasty, Balloon, Coronary , Cardiac Catheters , Coronary Artery Disease , Humans , Male , Female , Aged , Middle Aged , Treatment Outcome , Coronary Artery Disease/therapy , Coronary Artery Disease/diagnostic imaging , Angioplasty, Balloon, Coronary/instrumentation , Angioplasty, Balloon, Coronary/adverse effects , Retrospective Studies , Stents , Coronary Stenosis/diagnostic imaging , Coronary Stenosis/therapy , Coronary Stenosis/surgery , Risk Factors , Pressure , Time Factors , Percutaneous Coronary Intervention/adverse effects , Percutaneous Coronary Intervention/instrumentation
2.
Circ Cardiovasc Interv ; 17(5): e013302, 2024 May.
Article in English | MEDLINE | ID: mdl-38771909

ABSTRACT

Drug-coated balloons (DCBs) are specialized coronary devices comprised of a semicompliant balloon catheter with an engineered coating that allows the delivery of antiproliferative agents locally to the vessel wall during percutaneous coronary intervention. Although DCBs were initially developed more than a decade ago, their potential in coronary interventions has recently sparked renewed interest, especially in the United States. Originally designed to overcome the limitations of conventional balloon angioplasty and stenting, they aim to match or even improve upon the outcomes of drug-eluting stents without leaving a permanent implant. Presently, in-stent restenosis is the condition with the most robust evidence supporting the use of DCBs. DCBs provide improved long-term vessel patency compared with conventional balloon angioplasty and may be comparable to drug-eluting stents without the need for an additional stent layer, supporting their use as a first-line therapy for in-stent restenosis. Beyond the treatment of in-stent restenosis, DCBs provide an additional tool for de novo lesions for a strategy that avoids a permanent metal scaffold, which may be especially useful for the management of technically challenging anatomies such as small vessels and bifurcations. DCBs might also be advantageous for patients with high bleeding risk due to the decreased necessity for extended antiplatelet therapy, and in patients with diabetes and patients with diffuse disease to minimize long-stented segments. Further studies are crucial to confirm these broader applications for DCBs and to further validate safety and efficacy.


Subject(s)
Angioplasty, Balloon, Coronary , Cardiac Catheters , Cardiovascular Agents , Coated Materials, Biocompatible , Coronary Artery Disease , Coronary Restenosis , Humans , Coronary Artery Disease/therapy , Coronary Artery Disease/diagnostic imaging , Angioplasty, Balloon, Coronary/instrumentation , Angioplasty, Balloon, Coronary/adverse effects , Treatment Outcome , Coronary Restenosis/etiology , Coronary Restenosis/therapy , Cardiovascular Agents/administration & dosage , Cardiovascular Agents/adverse effects , Equipment Design , Risk Factors , Vascular Patency , Drug-Eluting Stents
3.
EuroIntervention ; 20(9): 602-612, 2024 May 10.
Article in English | MEDLINE | ID: mdl-38726721

ABSTRACT

BACKGROUND: Late lumen enlargement (LLE) - a positive remodelling phenomenon - after drug-coated balloon (DCB) angioplasty for stable coronary disease contributes to a lower restenosis rate. However, lesion characteristics promoting LLE remain unclear. AIMS: This study aimed to investigate predictive lesion characteristics for LLE using serial optical frequency domain imaging (OFDI) following DCB angioplasty for de novo coronary artery lesions. METHODS: This retrospective, single-centre observational study included patients with angina pectoris who underwent paclitaxel-coated balloon angioplasty without stenting under OFDI guidance as well as follow-up OFDI. OFDI endpoints were lumen volume, plaque phenotype, and procedure-associated dissection. LLE was defined as a ≥10% increase in the lumen volume of the treated lesion at follow-up. RESULTS: Between August 2016 and December 2019, among patients with successful DCB angioplasty, 108 lesions (83 patients) had available follow-up imaging after a median of 6.1 months. LLE was detected in 44 (40.7%) lesions. Fibrous/fibrocalcific and layered plaques had significantly larger lumen volumes at follow-up than immediately after the index procedure, whereas lipid plaques exhibited no significant difference. Medial dissection with an arc >90° revealed an increased lumen volume. Multivariate analysis showed that layered plaques (odds ratio [OR] 8.73, 95% confidence interval [CI]: 1.92-39.7; p=0.005) and medial dissection with an arc >90° (OR 4.65, 95% CI: 1.63-13.3; p=0.004) were independent LLE predictors. CONCLUSIONS: Layered plaques and extensive medial dissection after DCB angioplasty were associated with higher LLE occurrence in de novo coronary lesions. These findings may be clinically applicable to DCB therapeutic strategies based on plaque features.


Subject(s)
Angioplasty, Balloon, Coronary , Coronary Artery Disease , Paclitaxel , Humans , Male , Female , Aged , Middle Aged , Retrospective Studies , Angioplasty, Balloon, Coronary/instrumentation , Angioplasty, Balloon, Coronary/adverse effects , Angioplasty, Balloon, Coronary/methods , Coronary Artery Disease/therapy , Coronary Artery Disease/diagnostic imaging , Paclitaxel/therapeutic use , Paclitaxel/administration & dosage , Coronary Vessels/diagnostic imaging , Treatment Outcome , Coated Materials, Biocompatible , Plaque, Atherosclerotic , Tomography, Optical Coherence , Coronary Angiography
7.
Heart Vessels ; 39(6): 496-504, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38411631

ABSTRACT

Limited data exist regarding drug-coated balloon (DCB) treatment in de novo large coronary arteries. We sought to demonstrate procedural characteristics, residual stenosis, and clinical outcomes following DCB angioplasty for de novo lesions in large versus small coronary arteries. The study included 184 consecutive patients with 223 de novo coronary lesions undergoing paclitaxel DCB angioplasty between January 2019 and August 2020, who were divided according to whether the DCB diameter was ≥ 3.0 mm (large group, n = 58) or < 3.0 mm (small group, n = 125). The large group had a higher proportion of acute coronary syndrome more commonly with ostial, bifurcation, and calcified lesions in large vessels and received lesion preparation with more frequent use of scoring or cutting balloons and atherectomy devices compared to the small group. Postprocedural angiographic diameter stenosis was smaller in the large group compared to the small group (31% [22-37] vs. 35% [26-42], p = 0.032), and intravascular ultrasound revealed no significant difference in postprocedural area stenosis between the groups (66.2 ± 7.7% vs. 67.9 ± 7.8%; p = 0.26). The median follow-up duration was 995 days. The incidence of a composite of all-cause death, myocardial infarction, stroke, or target lesion revascularization was similar between the groups (log-rank p = 0.41) and was influenced by the presence of acute coronary syndrome and anemia but not by DCB diameter. The rate of cardiovascular outcomes after DCB treatment was comparable in de novo large and small coronary arteries. Notably, well-planned lesion preparation with intravascular imaging guidance was prevalent in large vessels.


Subject(s)
Angioplasty, Balloon, Coronary , Coated Materials, Biocompatible , Coronary Angiography , Coronary Artery Disease , Coronary Vessels , Humans , Male , Female , Angioplasty, Balloon, Coronary/adverse effects , Angioplasty, Balloon, Coronary/methods , Angioplasty, Balloon, Coronary/instrumentation , Aged , Coronary Vessels/diagnostic imaging , Treatment Outcome , Coronary Artery Disease/therapy , Coronary Artery Disease/diagnosis , Retrospective Studies , Middle Aged , Paclitaxel/administration & dosage , Follow-Up Studies
9.
J Invasive Cardiol ; 36(5)2024 May.
Article in English | MEDLINE | ID: mdl-38422535

ABSTRACT

A 73-year-old man, with a previous long drug-eluting stent (DES) from the mid-portion of the left main stem artery (LMS) to proximal left anterior descending artery (LAD), underwent elective coronary angiogram due to worsening anginal symptoms and an abnormal myocardial perfusion single photon emission computed tomography (SPECT) showing ischemia in the LAD territory.


Subject(s)
Angioplasty, Balloon, Coronary , Coronary Angiography , Drug-Eluting Stents , Humans , Aged , Male , Angioplasty, Balloon, Coronary/methods , Angioplasty, Balloon, Coronary/instrumentation , Equipment Failure , Tomography, Emission-Computed, Single-Photon , Coronary Vessels/diagnostic imaging , Coronary Artery Disease/diagnosis , Coronary Artery Disease/therapy , Coronary Artery Disease/surgery
11.
Int Heart J ; 63(1): 163-167, 2022.
Article in English | MEDLINE | ID: mdl-35095066

ABSTRACT

The incidence of acute coronary obstruction during transcatheter aortic valve implantation (TAVI) is low (< 1.0%); however, it is associated with high mortality. An 83-year-old female with a history of chest pain and syncope was diagnosed with severe aortic stenosis. Computed tomography showed severely calcified aortic leaflets with a low left coronary ostial height of 7.8 mm, which indicates a high risk of coronary obstruction. TAVI was performed using the right femoral artery approach under general anesthesia. To prevent coronary obstruction and minimize coronary flow obstruction, coronary protection of the left main tract (LMT) via the left radial artery was established with a perfusion balloon. We crossed a 23 mm Sapien 3 transcatheter heart valve and settled it at an appropriate position on the aortic valve. After inflation of the perfusion balloon at the LMT, we started rapid ventricular pacing, and deployed the Sapien 3 using the KBI technique. Hemodynamics were stable and aortography showed excellent coronary flow with no stenosis of the LMT ostium. This strategy may serve as a useful method to prevent coronary obstruction and minimize coronary ischemia.


Subject(s)
Angioplasty, Balloon, Coronary/instrumentation , Aortic Valve Stenosis/surgery , Coronary Occlusion/prevention & control , Transcatheter Aortic Valve Replacement/methods , Aged, 80 and over , Aortic Valve Stenosis/diagnostic imaging , Coronary Occlusion/etiology , Female , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/instrumentation
13.
J Diabetes Res ; 2021: 8636050, 2021.
Article in English | MEDLINE | ID: mdl-34859105

ABSTRACT

BACKGROUND: Cardiovascular disease (CVD) with significant involvement of coronary artery disease (CAD) remains a major cause of death and disability among the diabetic population. Although percutaneous coronary intervention (PCI) continues to evolve, type 2 diabetes mellitus (T2DM) is a well-established marker of poor clinical prognosis after PCI, which is mainly attributed to the rapid progression of atherosclerosis requiring recurrent revascularizations. Hence, the use of bioresorbable materials could provide some solution to this problem. Material and Methods. The study was divided into two arms. For the first one, we qualified 169 patients with NSTE-ACS treated with PCI who received the drug-eluting stent (DES) coated with a biodegradable polymer Ultimaster (Terumo, Tokyo, Japan). The second arm was composed of 193 patients with ACS who underwent PCI with a magnesium bioresorbable scaffold Magmaris (Biotronik, Berlin, Germany). Both arms were divided into two subsequent groups: the T2DM (59 and 72) and the non-DM (110 and 121, respectively). The primary outcomes were cardiovascular death, myocardial infarction, and in-stent thrombosis. The main secondary outcomes included target lesion failure (TLF) and were recorded at a 1-year-follow-up. RESULTS: There were no significant differences between the diabetic and nondiabetic populations in primary endpoints or main secondary endpoints (TLF, scaffold restenosis, death from any reason, and other cardiovascular events) either in the Ultimaster or Magmaris group. At a 1-year-follow-up, the primary endpoint in the DM t.2 population was recorded in 2.7% Ultimaster vs. 5.1% Magmaris, respectively. At the same time, the TLF occurred in the diabetic group in 4.1% Magmaris and 3.3% in the Ultimaster arm, respectively. CONCLUSION: Both, Ultimaster and Magmaris revealed relative safety and efficiency at a one-year follow-up in the diabetic population in ACS settings. The observed rates of TLF were low, which combined with a lack of in-stent thrombosis suggests that both investigated devices might be an interesting therapeutic option for diabetics with ACS. Nevertheless, further large randomized clinical trials are needed to confirm fully our results.


Subject(s)
Absorbable Implants , Acute Coronary Syndrome/therapy , Angioplasty, Balloon, Coronary/instrumentation , Cardiovascular Agents/administration & dosage , Diabetes Mellitus , Drug-Eluting Stents , Non-ST Elevated Myocardial Infarction/therapy , Sirolimus/administration & dosage , Acute Coronary Syndrome/diagnosis , Acute Coronary Syndrome/mortality , Aged , Angioplasty, Balloon, Coronary/adverse effects , Angioplasty, Balloon, Coronary/mortality , Cardiovascular Agents/adverse effects , Coronary Restenosis/etiology , Coronary Thrombosis/etiology , Diabetes Mellitus/diagnosis , Diabetes Mellitus/mortality , Female , Humans , Magnesium , Male , Middle Aged , Non-ST Elevated Myocardial Infarction/diagnosis , Non-ST Elevated Myocardial Infarction/mortality , Polymers , Prosthesis Design , Recurrence , Retrospective Studies , Risk Factors , Sirolimus/adverse effects , Time Factors , Treatment Outcome
14.
BMC Cardiovasc Disord ; 21(1): 360, 2021 07 30.
Article in English | MEDLINE | ID: mdl-34330212

ABSTRACT

BACKGROUND: The interventional treatment of calcified lesions with severe tortuosity in the left anterior descending artery (LAD) was challenging and the report of rotational atherectomy with mother-and-child technique has been scarce. CASE PRESENTATION: An 84-year-old woman was hospitalized for non-ST-segment acute coronary syndrome. Coronary angiography revealed a calcified nodule in the LAD. During rotational atherectomy of the calcified and tortuous lesion in the proximal LAD, eccentric cutting due to wire bias nearly caused perforation. The burr seemed to protrude from the contrast media during angiography. Intravascular ultrasound imaging revealed that extremely eccentric ablation almost reached the adventitia. We successfully ablated the distal calcified nodule by preventing proximal overcutting of the tortuous lesion with support from a guide extension catheter, i.e., the mother-and-child technique, followed by the deployment of the drug-eluting stent. The patient was discharged without chest symptoms and no symptom recurred during 12-month follow-up. CONCLUSION: This case demonstrated that safe ablation of a calcified nodule located distal to a tortuous and calcified lesion in the proximal LAD with the mother-and-child technique.


Subject(s)
Atherectomy, Coronary/instrumentation , Cardiac Catheterization/instrumentation , Cardiac Catheters , Coronary Artery Disease/therapy , Vascular Calcification/therapy , Aged, 80 and over , Angioplasty, Balloon, Coronary/instrumentation , Coronary Artery Disease/diagnostic imaging , Drug-Eluting Stents , Female , Humans , Treatment Outcome , Vascular Calcification/diagnostic imaging
15.
Am Heart J ; 241: 101-107, 2021 11.
Article in English | MEDLINE | ID: mdl-34314727

ABSTRACT

BACKGROUND: Drug-coated balloon (DCB) technology was developed as an alternative treatment for obstructive coronary artery disease (CAD) and in-stent restenosis (ISR). Management of coronary ISR is clinically challenging and frequently encountered in practice. The Agent DCB uses an inactive excipient to effectively deliver a targeted, therapeutic dose of paclitaxel to the vessel wall. STUDY DESIGN: AGENT IDE is a prospective, multicenter, randomized controlled trial to evaluate superiority of the Agent DCB to balloon angioplasty in treating patients with ISR. A total of 480 patients with ISR of a previously treated lesion length <26 mm and reference vessel diameter >2.0 mm to ≤4.0 mm will be initially randomized. Subjects presenting with recent myocardial infarction (MI), complex lesions, or thrombus in the target vessel will be excluded. An adaptive group sequential design with one formal interim analysis for sample size re-estimation will be conducted, and the sample size may be increased to a maximum of 600 subjects. The primary endpoint is the rate of 12-month target lesion failure (TLF; composite of any ischemia-driven revascularization of the target lesion (TLR), target vessel related MI, or cardiac death) and will be tested for superiority in the test arm against the control. Functional status and general health-related quality of life will be measured by changes in the EQ-5D scores. Subjects will be followed for 5 years following the index procedure. CONCLUSION: This study will prospectively evaluate the safety and efficacy of Agent DCB in patients treated for coronary ISR.


Subject(s)
Angioplasty, Balloon, Coronary , Cardiac Catheters/classification , Coronary Artery Disease/surgery , Coronary Restenosis , Paclitaxel/pharmacology , Reoperation , Angioplasty, Balloon, Coronary/adverse effects , Angioplasty, Balloon, Coronary/instrumentation , Angioplasty, Balloon, Coronary/methods , Antineoplastic Agents, Phytogenic/pharmacology , Coated Materials, Biocompatible/pharmacology , Coronary Restenosis/diagnosis , Coronary Restenosis/etiology , Coronary Restenosis/surgery , Drug-Eluting Stents/adverse effects , Female , Humans , Male , Middle Aged , Multicenter Studies as Topic , Randomized Controlled Trials as Topic , Reoperation/adverse effects , Reoperation/instrumentation , Reoperation/methods
16.
J Interv Cardiol ; 2021: 9962313, 2021.
Article in English | MEDLINE | ID: mdl-34121951

ABSTRACT

OBJECTIVES: The present study was designed to compare the characteristics and performance regarding drug delivery of a novel drug-coated balloon (DCB) to a benchmark device (Restore® versus SeQuent® Please) in an in vitro and in vivo model. BACKGROUND: Although Restore® and SeQuent® are both paclitaxel-coated, they use different coating excipient, shellac-ammonium salt and iopromide, respectively. Preclinical study comparing these two different commercial DCBs regarding their characteristics and effects on early vascular response is sparse. METHODS: Restore® and SeQuent® DCBs were scanned with electron microscopy for surface characteristic assessment. Both DCBs were transported in an in vitro vessel model for the evaluation of drug wash-off rate and particulate formation. Eighteen coronary angioplasties with either Restore® or SeQuent® DCBs were conducted in 6 swine (three coronary vessels each). Histopathological images of each vessel were evaluated for vessel injury. RESULTS: The surface of Restore® DCB was smooth and evenly distributed with hardly visible crystal, while SeQuent® DCB showed a rougher surface with relatively larger apparent crystals. Restore® DCB had a lower drug wash-off rate and fewer large visible particles, compared to the SeQuent® DCB. No significant difference in mean injure score was found between Restore® and SeQuent® group. CONCLUSION: Our results suggest that Restore® is better in preclinical performance regarding less release of particles and lower drug wash-off rate as compared to SeQuent® Please. The Restore® DCB, using stable amorphous coating and shellac-ammonium salt as an excipient, appears to provide an advantage in drug delivery efficacy; however, further clinical studies are warranted.


Subject(s)
Ammonium Compounds/pharmacology , Angioplasty, Balloon, Coronary/instrumentation , Cardiac Catheters , Coronary Vessels/surgery , Paclitaxel/pharmacology , Resins, Plant/pharmacology , Angioplasty, Balloon, Coronary/methods , Animals , Antineoplastic Agents, Phytogenic/pharmacology , Coated Materials, Biocompatible/pharmacology , Drug Delivery Systems , Materials Testing/methods , Surface Properties , Swine
17.
BMC Cardiovasc Disord ; 21(1): 290, 2021 06 11.
Article in English | MEDLINE | ID: mdl-34116631

ABSTRACT

BACKGROUND: To compare the effect and outcomes of optical coherence tomography (OCT)-guided rotational atherectomy (RA) with intravascular ultrasound (IVUS)-guided RA in the treatment of calcified coronary lesions. METHODS: Data of calcified coronary lesions treated with RA that underwent OCT-guided or IVUS-guided from January 2016 to December 2019 at a single-center registry were retrospectively analyzed. The effect and outcomes between underwent OCT-guided RA and IVUS-guided RA were compared. RESULTS: A total of 33 lesions in 32 patients received OCT-guided RA and 51 lesions in 47 patients received IVUS-guided RA. There was no significant difference between OCT-guided RA group and IVUS-guided RA group in clinical baselines characteristics. Comparing the procedural and lesions characteristics of the two groups, the contrast volume was larger [(348.8 ± 110.6) ml vs. (275.2 ± 76.8) ml, P = 0.002] and the scoring balloon was more frequently performed (33.3% vs. 3.9%, P = 0.001) after RA and before stenting in the OCT-guided RA group. Comparing the intravascular imaging findings of the two groups, stent expansion was significantly larger in the OCT-guided RA group ([82 ± 8]% vs. [75 ± 9]%, P = 0.001). Both groups achieved procedural success immediately. There were no significantly differences in the incidence of complications. Although there was no statistical difference in the occurrence of MACE at 1 year between OCT-guided RA group and IVUS-guided RA group (3.1% vs. 6.4%, P = 0.517), no cardiovascular death, TVR and stent thrombosis occurred in OCT-guided RA group. CONCLUSIONS: OCT-guided RA compared to IVUS-guided RA for treating calcified coronary lesions resulted in better stent expansion and may have improved prognosis.


Subject(s)
Angioplasty, Balloon, Coronary , Atherectomy, Coronary , Coronary Artery Disease/therapy , Tomography, Optical Coherence , Ultrasonography, Interventional , Vascular Calcification/therapy , Aged , Aged, 80 and over , Angioplasty, Balloon, Coronary/adverse effects , Angioplasty, Balloon, Coronary/instrumentation , Atherectomy, Coronary/adverse effects , Coronary Artery Disease/diagnostic imaging , Female , Humans , Male , Middle Aged , Registries , Retrospective Studies , Stents , Tomography, Optical Coherence/adverse effects , Treatment Outcome , Ultrasonography, Interventional/adverse effects , Vascular Calcification/diagnostic imaging
18.
Angiology ; 72(10): 971-978, 2021 11.
Article in English | MEDLINE | ID: mdl-33957806

ABSTRACT

Limited data exist about the effect of intracoronary imaging (ICI)-guided drug-coated balloon (DCB) intervention on clinical end points. In all, 1157 patients with coronary artery disease treated with DCB between December 2014 and December 2017 at Beijing Anzhen Hospital were included in the final analysis in this cohort study. The primary end point was the incidence of target lesion failure (TLF), a composite of cardiac death, target vessel myocardial infarction (MI), and target lesion revascularization, and the key secondary end point was the incidence of cardiac death or target vessel MI. The median follow-up for clinical events was 32.0 months (IQR 25.0-40.0). Intracoronary imaging was used in 90 (7.8%) patients. There was no statistically significant difference in TLF (12.2% vs 12.5%, P = .80) between ICI-guided and angiography-guided group. Cardiac death or target vessel MI rates (1.1% vs 3.7%, P = .17) were numerically lower for the ICI-guided cohort. In the propensity score-based analysis, TLF (10.5% vs 16.2%, P = .19) and cardiac death or target vessel MI rates (1.2% vs 2.3%, P = .51) tended to be lower for the ICI-guided cohort. In this observational study, TLF rate tended to decrease in the ICI-guided DCB treatment group compared with angiography-guided procedures. Larger studies are needed.


Subject(s)
Angioplasty, Balloon, Coronary/instrumentation , Cardiac Catheters , Coated Materials, Biocompatible , Coronary Angiography , Coronary Artery Disease/therapy , Aged , Angioplasty, Balloon, Coronary/adverse effects , Angioplasty, Balloon, Coronary/mortality , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/mortality , Female , Humans , Male , Middle Aged , Myocardial Infarction/microbiology , Pilot Projects , Predictive Value of Tests , Propensity Score , Risk Assessment , Risk Factors , Time Factors , Treatment Outcome
19.
BMC Cardiovasc Disord ; 21(1): 232, 2021 05 07.
Article in English | MEDLINE | ID: mdl-33962571

ABSTRACT

BACKGROUND: The jailed balloon technique is widely used for coronary bifurcation lesions, but a residual risk of SB occlusion remains, necessitating SB rewiring and further interventions, including balloon inflation or stenting, which may result in failure and SB loss. This study introduced a novel modified technique of small side branch (SB) protection, namely, double kissing inflation outside the stent (DKo) technique, for coronary bifurcations without the need for SB rewiring. METHODS: We performed the DKo technique in consecutive patients in our center from 1/2019 to 12/2019. The procedure was as follows. We inserted a guide wire into both branches followed by proper preparation. The SB balloon was simultaneously inflated with main vessel (MV) stenting. The SB balloon remained in situ until it was kissing inflated with postdilation of the bifurcation core, which is different from traditional strategies. The proximal optimization technique was performed with a short noncompliant balloon strictly not exceeding the bifurcation. Rates of SB loss and in-hospital outcomes were evaluated. RESULTS: The technique was successfully performed in all 117 enrolled patients without any rewiring or SB loss. The mean lesion lengths of the MV and SB were 38.3 ± 19.9 mm and 11.7 ± 7.1 mm, respectively. On average, 1.5 ± 0.6 stents were used per patient, while the mean pressure of the SB balloon was 7.4 ± 3.1 atm. DKo achieved excellent procedural success in the proximal and distal MVs: increased minimal lumen diameter (0.64 ± 0.58 mm to 3.05 ± 0.38 mm, p < 0.001; 0.57 ± 0.63 mm to 2.67 ± 0.35 mm, p < 0.001) and low residual stenosis (11.4 ± 3.4%; 7.2 ± 4.6%). DKo secured the patency of the SB without any rewiring and improved the SB stenosis with minimal lumen diameter (0.59 ± 0.48 mm to 1.20 ± 0.42 mm, p < 0.001) and stenosis (71.9 ± 19.4% to 42.2 ± 14.0%, p < 0.001). No MACE was noted in the hospital. CONCLUSIONS: DKo for bifurcation lesions was shown to be acceptable with high procedural success and excellent SB protection.


Subject(s)
Angioplasty, Balloon, Coronary/instrumentation , Coronary Artery Disease/therapy , Stents , Vascular Patency , Aged , Angioplasty, Balloon, Coronary/adverse effects , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/physiopathology , Female , Humans , Male , Middle Aged , Retrospective Studies , Time Factors , Treatment Outcome
20.
Angiology ; 72(10): 986-993, 2021 11.
Article in English | MEDLINE | ID: mdl-33982603

ABSTRACT

We evaluated the angiographic parameter and clinical outcomes of drug-coated balloon (DCB) to assess the optimal angiographic criteria in de novo small vessel disease (SVD). Patients (n = 424, mean age: 64.4 ± 11.2 years, men: 69.8%) at 20 sites in Korea were prospectively enrolled. The primary end point was late luminal loss (LLL) at 9-month follow-up angiography. Secondary end points included restenosis rates, target lesion failure (TLF), and DCB-related thrombosis during the 12-month follow-up period. We included 403 patients for analysis excluding 21 patients who required bailout stenting. Baseline mean reference vessel .diameter was 2.52 ± 0.39 mm and mean minimal luminal diameter (MLD) was 0.71 ± 0.40 mm. The mean MLD was 1.54 ± 0.37 mm after DCB. Late luminal loss was -0.01 ± 0.43 mm and restenosis was noted in 26 patients (12.2%). Minimal luminal diameter >1.6 mm and %diameter stenosis (DS) <45% after DCB was associated maintenance of MLD without LLL at 9-months. Multivariate analysis demonstrated that %DS at baseline and post-MLD was associated with the restenosis. During 12-month follow-up, TLF was 2.6% including 1 cardiac death, 1 myocardial infarction, and 10 ischemia-driven target lesion revascularizations. Drug-coated balloon showed a low restenosis and lower LLL despite high in-segment DS. Post-MLD and % DS may be helpful to get optimal results in de novo SVD after DCB.


Subject(s)
Angioplasty, Balloon, Coronary/instrumentation , Cardiac Catheters , Cardiovascular Agents/administration & dosage , Coated Materials, Biocompatible , Coronary Angiography , Coronary Artery Disease/therapy , Coronary Vessels/diagnostic imaging , Paclitaxel/administration & dosage , Aged , Angioplasty, Balloon, Coronary/adverse effects , Cardiovascular Agents/adverse effects , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/mortality , Coronary Restenosis/diagnostic imaging , Coronary Restenosis/etiology , Equipment Design , Female , Humans , Male , Middle Aged , Paclitaxel/adverse effects , Predictive Value of Tests , Prospective Studies , Registries , Republic of Korea , Risk Assessment , Risk Factors , Time Factors , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...