Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 9.894
Filter
2.
J Cardiovasc Med (Hagerstown) ; 25(7): 529-538, 2024 Jul 01.
Article in English | MEDLINE | ID: mdl-38829939

ABSTRACT

AIMS: This study assessed the outcomes of concomitant mitral valve disease and severe aortic stenosis in patients undergoing transcatheter aortic valve replacement (TAVR). METHODS: Echocardiographic data of 813 patients with severe aortic stenosis undergoing transfemoral TAVR were collected, and clinical outcomes were analyzed for individuals with mitral stenosis and mitral regurgitation. RESULTS: The final cohort includes 788 patients with severe calcific aortic stenosis. Among single parameters of mitral stenosis, a smaller baseline mitral valve area (MVA) by the continuity equation and higher postprocedural mean mitral gradients (MMG) were associated with an increased risk of death at 1 year (P-values 0.02 and <0.01, respectively), but no correlation with outcomes was demonstrated after multivariate adjustment for major prognosticators. Mitral stenosis (based on MVA + MMG) was not associated with complications or mortality. Mitral regurgitation was present in 94.6% of the population at baseline and regressed by at least one grade post-TAVR in 28% of the patients. The improvement in mitral regurgitation was associated with a greater prosthetic effective orifice area (P-value 0.03). Significant (at least moderate) residual mitral regurgitation was correlated with short-term complications and shown to be an independent predictor of 1-year mortality (P-value 0.02, odds ratio (OR) 5.37, confidence interval 1.34-21.5). CONCLUSION: Mitral regurgitation has a greater impact on TAVR patients than mitral stenosis as assessed by functional methods.


Subject(s)
Aortic Valve Stenosis , Mitral Valve Insufficiency , Mitral Valve Stenosis , Transcatheter Aortic Valve Replacement , Humans , Male , Female , Mitral Valve Stenosis/surgery , Mitral Valve Stenosis/diagnostic imaging , Mitral Valve Stenosis/mortality , Mitral Valve Stenosis/physiopathology , Mitral Valve Stenosis/complications , Mitral Valve Insufficiency/surgery , Mitral Valve Insufficiency/physiopathology , Mitral Valve Insufficiency/mortality , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/complications , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/mortality , Aged, 80 and over , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/mortality , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/physiopathology , Aortic Valve Stenosis/complications , Aged , Treatment Outcome , Severity of Illness Index , Retrospective Studies , Prognosis , Risk Factors , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Aortic Valve/pathology , Calcinosis/mortality , Calcinosis/diagnostic imaging , Calcinosis/complications , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Mitral Valve/physiopathology , Echocardiography
3.
Echocardiography ; 41(6): e15859, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38853624

ABSTRACT

Aortic stenosis (AS) stands as the most common valvular heart disease in developed countries and is characterized by progressive narrowing of the aortic valve orifice resulting in elevated transvalvular flow resistance, left ventricular hypertrophy, and progressive increased risk of heart failure and sudden death. This narrative review explores clinical challenges and evolving perspectives in moderate AS, where discrepancies between aortic valve area and pressure gradient measurements may pose diagnostic and therapeutic quandaries. Transthoracic echocardiography is the first-line imaging modality for AS evaluation, yet cases of discordance may require the application of ancillary noninvasive diagnostic modalities. This review underscores the importance of accurate grading of AS severity, especially in low-gradient phenotypes, emphasizing the need for vigilant follow-up. Current clinical guidelines primarily recommend aortic valve replacement for severe AS, potentially overlooking latent risks in moderate disease stages. The noninvasive multimodality imaging approach-including echocardiography, cardiac magnetic resonance, computed tomography, and nuclear techniques-provides unique insights into adaptive and maladaptive cardiac remodeling in AS and offers a promising avenue to deliver precise indications and exact timing for intervention in moderate AS phenotypes and asymptomatic patients, potentially improving long-term outcomes. Nevertheless, what we may have gleaned from a large amount of observational data is still insufficient to build a robust framework for clinical decision-making in moderate AS. Future research will prioritize randomized clinical trials designed to weigh the benefits and risks of preemptive aortic valve replacement in the management of moderate AS, as directed by specific imaging and nonimaging biomarkers.


Subject(s)
Aortic Valve Stenosis , Aortic Valve , Echocardiography , Humans , Aortic Valve Stenosis/physiopathology , Aortic Valve Stenosis/surgery , Echocardiography/methods , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve/physiopathology , Severity of Illness Index
7.
Laeknabladid ; 110(5): 247-253, 2024 May.
Article in Icelandic | MEDLINE | ID: mdl-38713559

ABSTRACT

INTRODUCTION: One of the most serious complications of surgical aortic valve replacement (SAVR) is stroke that can result in increased rates of complications, morbidity and mortality postoperatively. The aim of this study was to investigate incidence, risk factors and short-term outcome in a well defined cohort of SAVR-patients. MATERIALS AND METHOD: A retrospective study on 740 consecutive aortic stenosis patients who underwent SAVR in Iceland 2002-2019. Patients with stroke were compared with non-stroke patients; including preoperative risk factors of cardiovascular disease, echocardiogram-results, rate of early postoperative complications other than stroke and 30 day mortality. RESULTS: Mean age was 71 yrs (34% females) with 57% of the patients receiving stented bioprosthesis, 31% a stentless Freestyle®-valve and 12% a mechanical valve. Mean EuroSCORE-II was 3.6, with a maximum preop-gradient of 70 mmHg and an estimated valvular area of 0.73 cm2. Thirteen (1.8%) patients were diagnosed with stroke where hemiplegia (n=9), loss of consciousness (n=3) and/or aphasia (n=4) were the most common presenting symptoms. In 70% of cases the neurological symptoms resolved or disappeared in the first weeks and months after surgery. Only one patient out of 13 died within 30-days (7.7%). Stroke-patients had significantly lower BMI than non-stroke patients, but other risk factors of cardiovascular diseases, intraoperative factors or the rate of other severe postoperative complications than stroke were similar between groups. Total length of stay was 14 days vs. 10 days median, including 2 vs. 1 days in the ICU, in the stroke and non-stroke-groups, respectively. CONCLUSIONS: The rate of stroke after SAVR was low (1.8%) and in line with other similar studies. Although a severe complication, most patients with perioperative stroke survived 30 days postoperatively and in majority of cases neurological symptoms recovered.


Subject(s)
Aortic Valve Stenosis , Aortic Valve , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Stroke , Humans , Female , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/mortality , Aortic Valve Stenosis/diagnostic imaging , Male , Aged , Risk Factors , Retrospective Studies , Iceland/epidemiology , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/mortality , Heart Valve Prosthesis Implantation/instrumentation , Stroke/epidemiology , Stroke/mortality , Stroke/etiology , Incidence , Time Factors , Treatment Outcome , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Risk Assessment , Aged, 80 and over , Middle Aged
8.
Ann Card Anaesth ; 27(1): 51-52, 2024 Jan 01.
Article in English | MEDLINE | ID: mdl-38722121

ABSTRACT

ABSTRACT: The quadricuspid aortic valve is a rare congenital anomaly, usually associated with aortic regurgitation requiring surgical intervention. It may be associated with other congenital anomalies such as coronary anomalies, patent ductus arteriosus, ventricular septal defect, pulmonary stenosis, and subaortic stenosis. The diagnosis is generally established by either transthoracic or transesophageal echocardiography. Herein, we report a case of a 52-year-old woman who was diagnosed to have quadricuspid aortic valve by intraoperative transesophageal echocardiography.


Subject(s)
Aortic Valve , Echocardiography, Transesophageal , Humans , Female , Aortic Valve/abnormalities , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Middle Aged , Echocardiography, Transesophageal/methods , Aortic Valve Insufficiency/surgery , Aortic Valve Insufficiency/diagnostic imaging , Heart Defects, Congenital/diagnostic imaging , Heart Defects, Congenital/surgery
9.
J Cardiothorac Surg ; 19(1): 281, 2024 May 07.
Article in English | MEDLINE | ID: mdl-38715080

ABSTRACT

Injury to coronary arteries during mitral surgery is a rare but life-threatening procedural complication, an anomalous origin and course of the left circumflex artery (LCx) increase this risk. Recognizing the anomaly by the characteristic angiographic pattern and identifying its relationship with the surrounding anatomical structure using imaging techniques, mainly transesophageal echocardiography (TOE) or coronary computed tomography angiography (CCTA), is of crucial importance in setting up the best surgical strategy. We report a case of anomalous origin of a circumflex artery (LCx) from the proximal portion of the right coronary artery (RCA) with a pathway running retroaortically through the mitro-aortic space. An integrated diagnostic approach using a multidisciplinary team with a cardiologist and an imaging radiologist allowed us to decide the surgical strategy. We successfully performed a mitral valvular repair using a minimally invasive minithoracotomic approach and implanting a complete semirigid ring.


Subject(s)
Aortic Valve , Coronary Vessel Anomalies , Echocardiography, Transesophageal , Mitral Valve , Humans , Mitral Valve/surgery , Mitral Valve/diagnostic imaging , Mitral Valve/abnormalities , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Aortic Valve/abnormalities , Coronary Vessel Anomalies/surgery , Coronary Vessel Anomalies/diagnostic imaging , Coronary Angiography , Computed Tomography Angiography , Male , Mitral Valve Insufficiency/surgery , Mitral Valve Insufficiency/diagnostic imaging , Female , Coronary Vessels/surgery , Coronary Vessels/diagnostic imaging
10.
Circ Cardiovasc Imaging ; 17(5): e016267, 2024 May.
Article in English | MEDLINE | ID: mdl-38771899

ABSTRACT

BACKGROUND: Aortic valve calcification (AVC) indexation to the aortic annulus (AA) area measured by Doppler echocardiography (AVCdEcho) provides powerful prognostic information in patients with aortic stenosis (AS). However, the indexation by AA measured by multidetector computed tomography (AVCdCT) has never been evaluated. The aim of this study was to compare AVC, AVCdCT, and AVCdEcho with regard to hemodynamic correlations and clinical outcomes in patients with AS. METHODS: Data from 889 patients, mainly White, with calcific AS who underwent Doppler echocardiography and multidetector computed tomography within the same episode of care were retrospectively analyzed. AA was measured both by Doppler echocardiography and multidetector computed tomography. AVCdCT severity thresholds were established using receiver operating characteristic curve analyses in men and women separately. The primary end point was the occurrence of all-cause mortality. RESULTS: Correlations between gradient/velocity and AVCd were stronger (both P≤0.005) using AVCdCT (r=0.68, P<0.001 and r=0.66, P<0.001) than AVC (r=0.61, P<0.001 and r=0.60, P<0.001) or AVCdEcho (r=0.61, P<0.001 and r=0.59, P<0.001). AVCdCT thresholds for the identification of severe AS were 334 Agatston units (AU)/cm2 for women and 467 AU/cm2 for men. On a median follow-up of 6.62 (6.19-9.69) years, AVCdCT ratio was superior to AVC ratio and AVCdEcho ratio to predict all-cause mortality in multivariate analyses (hazard ratio [HR], 1.59 [95% CI, 1.26-2.00]; P<0.001 versus HR, 1.53 [95% CI, 1.11-1.65]; P=0.003 versus HR, 1.27 [95% CI, 1.11-1.46]; P<0.001; all likelihood test P≤0.004). AVCdCT ratio was superior to AVC ratio and AVCdEcho ratio to predict survival under medical treatment in multivariate analyses (HR, 1.80 [95% CI, 1.27-1.58]; P<0.001 compared with HR, 1.55 [95% CI, 1.13-2.10]; P=0.007; HR, 1.28 [95% CI, 1.03-1.57]; P=0.01; all likelihood test P<0.03). AVCdCT ratio predicts mortality in all subgroups of patients with AS. CONCLUSIONS: AVCdCT appears to be equivalent or superior to AVC and AVCdEcho to assess AS severity and predict all-cause mortality. Thus, it should be used to evaluate AS severity in patients with nonconclusive echocardiographic evaluations with or without low-flow status. AVCdCT thresholds of 300 AU/cm2 for women and 500 AU/cm2 for men seem to be appropriate to identify severe AS. Further studies are needed to validate these thresholds, especially in diverse populations.


Subject(s)
Aortic Valve Stenosis , Aortic Valve , Calcinosis , Echocardiography, Doppler , Multidetector Computed Tomography , Predictive Value of Tests , Severity of Illness Index , Humans , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/physiopathology , Aortic Valve Stenosis/mortality , Male , Female , Multidetector Computed Tomography/methods , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Aortic Valve/pathology , Retrospective Studies , Aged , Calcinosis/diagnostic imaging , Calcinosis/physiopathology , Calcinosis/mortality , Echocardiography, Doppler/methods , Aged, 80 and over , Prognosis , ROC Curve , Hemodynamics , Middle Aged , Risk Factors
13.
Sci Rep ; 14(1): 10409, 2024 05 06.
Article in English | MEDLINE | ID: mdl-38710782

ABSTRACT

In transcatheter aortic valve implantation (TAVI), final device position may be affected by device interaction with the whole aortic landing zone (LZ) extending to ascending aorta. We investigated the impact of aortic LZ curvature and angulation on TAVI implantation depth, comparing short-frame balloon-expanding (BE) and long-frame self-expanding (SE) devices. Patients (n = 202) treated with BE or SE devices were matched based on one-to-one propensity score. Primary endpoint was the mismatch between the intended (HPre) and the final (HPost) implantation depth. LZ curvature and angulation were calculated based on the aortic centerline trajectory available from pre-TAVI computed tomography. Total LZ curvature ( k L Z , t o t ) and LZ angulation distal to aortic annulus ( α L Z , D i s t a l ) were greater in the SE compared to the BE group (P < 0.001 for both). In the BE group, HPost was significantly higher than HPre at both cusps (P < 0.001). In the SE group, HPost was significantly deeper than HPre only at the left coronary cusp (P = 0.013). At multivariate analysis, α L Z , D i s t a l was the only independent predictor (OR = 1.11, P = 0.002) of deeper final implantation depth with a cut-off value of 17.8°. Aortic LZ curvature and angulation significantly affected final TAVI implantation depth, especially in high stent-frame SE devices reporting, upon complete release, deeper implantation depth with respect to the intended one.


Subject(s)
Aortic Valve Stenosis , Aortic Valve , Transcatheter Aortic Valve Replacement , Transcatheter Aortic Valve Replacement/methods , Humans , Male , Female , Aged, 80 and over , Aged , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Aortic Valve Stenosis/surgery , Tomography, X-Ray Computed , Aorta/diagnostic imaging , Aorta/surgery , Treatment Outcome , Heart Valve Prosthesis , Retrospective Studies
14.
Ann Card Anaesth ; 27(1): 53-57, 2024 Jan 01.
Article in English | MEDLINE | ID: mdl-38722122

ABSTRACT

ABSTRACT: Aortic valve (AV) repair is the desired surgical treatment option for young patients with aortic regurgitation (AR). It is considered as a class I indication for the surgical treatment of severeAR. The success of an AV repair depends on the detailed intraoperative transesophageal echocardiographic (TEE) examination which should fulfil the information required by the surgeon. The objective of this echo round is to describe the role of intraoperative TEE in systematic evaluation of the AV, before and after repair.


Subject(s)
Aortic Valve Insufficiency , Aortic Valve , Echocardiography, Transesophageal , Monitoring, Intraoperative , Child , Humans , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Aortic Valve Insufficiency/surgery , Aortic Valve Insufficiency/diagnostic imaging , Echocardiography, Transesophageal/methods , Monitoring, Intraoperative/methods
15.
Eur J Cardiothorac Surg ; 65(5)2024 May 03.
Article in English | MEDLINE | ID: mdl-38710669

ABSTRACT

OBJECTIVES: The objective of this analysis was to assess the normal haemodynamic performance of contemporary surgical aortic valves at 1 year postimplant in patients undergoing surgical aortic valve replacement for significant valvular dysfunction. By pooling data from 4 multicentre studies, this study will contribute to a better understanding of the effectiveness of surgical aortic valve replacement procedures, aiding clinicians and researchers in making informed decisions regarding valve selection and patient management. METHODS: Echocardiograms were assessed by a single core laboratory. Effective orifice area, dimensionless velocity index, mean aortic gradient, peak aortic velocity and stroke volume were evaluated. RESULTS: The cohort included 2958 patients. Baseline age in the studies ranged from 70.1 ± 9.0 to 83.3 ± 6.4 years, and Society of Thoracic Surgeons risk of mortality was 1.9 ± 0.7 to 7.5 ± 3.4%. Twenty patients who had received a valve model implanted in fewer than 10 cases were excluded. Ten valve models (all tissue valves; n = 2938 patients) were analysed. At 1 year, population mean effective orifice area ranged from 1.46 ± 0.34 to 2.12 ± 0.59 cm2, and dimensionless velocity index, from 0.39 ± 0.07 to 0.56 ± 0.15. The mean gradient ranged from 8.6 ± 3.4 to 16.1 ± 6.2 mmHg with peak aortic velocity of 1.96 ± 0.39 to 2.65 ± 0.47 m/s. Stroke volume was 75.3 ± 19.6 to 89.8 ± 24.3 ml. CONCLUSIONS: This pooled cohort is the largest to date of contemporary surgical aortic valves with echocardiograms analysed by a single core lab. Overall haemodynamic performance at 1 year ranged from good to excellent. These data can serve as a benchmark for other studies and may be useful to evaluate the performance of bioprosthetic surgical valves over time. CLINICAL TRIAL REGISTRATION NUMBER: NCT02088554, NCT02701283, NCT01586910 and NCT01531374.


Subject(s)
Aortic Valve , Bioprosthesis , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Hemodynamics , Humans , Hemodynamics/physiology , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Aged , Female , Male , Aged, 80 and over , Heart Valve Prosthesis Implantation/methods , Echocardiography , Middle Aged , Prosthesis Design
16.
EuroIntervention ; 20(9): 579-590, 2024 May 10.
Article in English | MEDLINE | ID: mdl-38726714

ABSTRACT

BACKGROUND: Data on the performance of the latest-generation SAPIEN 3 Ultra RESILIA (S3UR) valve in patients who undergo transcatheter aortic valve replacement (TAVR) are scarce. AIMS: We aimed to assess the clinical outcomes, including valve performance, of the S3UR. METHODS: Registry data of 618 consecutive patients with S3UR and of a historical pooled cohort of 8,750 patients who had a SAPIEN 3 (S3) valve and underwent TAVR were collected. The clinical outcomes and haemodynamics, including patient-prosthesis mismatch (PPM), were compared between the 2 groups and in a propensity-matched cohort. RESULTS: The incidence of in-hospital death, vascular complications, and new pacemaker implantation was similar between the S3UR and the S3 groups (allp>0.05). However, both groups showed significant differences in the degrees of paravalvular leakage (PVL) (none-trivial: 87.0% vs 78.5%, mild: 12.5% vs 20.5%, ≥moderate: 0.5% vs 1.1%; p<0.001) and the incidence of PPM (none: 94.3% vs 85.1%, moderate: 5.2% vs 12.8%, severe: 0.5% vs 2.0%; p<0.001). The prevalence of a mean pressure gradient ≥20 mmHg was significantly lower in the S3UR group (1.6% vs 6.2%; p<0.001). Better haemodynamics were observed with the smaller 20 mm and 23 mm S3UR valves. The results were consistent in a matched cohort of patients with S3UR and with S3 (n=618 patients/group). CONCLUSIONS: The S3UR has equivalent procedural complications to the S3 but with lower rates of PVL and significantly better valve performance. The better valve performance of the S3UR, particularly in smaller valve sizes, overcomes the remaining issue of balloon-expandable valves after TAVR.


Subject(s)
Aortic Valve Stenosis , Aortic Valve , Heart Valve Prosthesis , Registries , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/instrumentation , Transcatheter Aortic Valve Replacement/methods , Female , Male , Aged, 80 and over , Aged , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/physiopathology , Treatment Outcome , Aortic Valve/surgery , Aortic Valve/physiopathology , Aortic Valve/diagnostic imaging , Prosthesis Design , Hemodynamics , Postoperative Complications/epidemiology , Postoperative Complications/etiology , Hospital Mortality
17.
Europace ; 26(5)2024 May 02.
Article in English | MEDLINE | ID: mdl-38691562

ABSTRACT

AIMS: We examined whether thickness of the basal muscular interventricular septum (IVS), as measured by pre-procedural computed tomography (CT), could be used to identify the risk of conduction disturbances following transcatheter aortic valve replacement (TAVR). The IVS is a pivotal region of the electrical conduction system of the heart where the atrioventricular conduction axis is located. METHODS AND RESULTS: Included were 78 patients with severe aortic stenosis who underwent CT imaging prior to TAVR. The thickness of muscular IVS was measured in the coronal view, in systolic phases, at 1, 2, 5, and 10 mm below the membranous septum (MS). The primary endpoint was a composite of conduction disturbance following TAVR. Conduction disturbances occurred in 24 out of 78 patients (30.8%). Those with conduction disturbances were significantly more likely to have a thinner IVS than those without conduction disturbances at every measured IVS level (2.98 ± 0.52 mm vs. 3.38 ± 0.52 mm, 4.10 ± 1.02 mm vs. 4.65 ± 0.78 mm, 6.11 ± 1.12 mm vs. 6.88 ± 1.03 mm, and 9.72 ± 1.95 mm vs. 10.70 ± 1.55 mm for 1, 2, 5 and 10 mm below MS, respectively, P < 0.05 for all). Multivariable logistic regression analysis showed that pre-procedural IVS thickness (<4 mm at 2 mm below the MS) was a significant independent predictor of post-procedural conduction disturbance (adjOR 7.387, 95% CI: 2.003-27.244, P = 0.003). CONCLUSION: Pre-procedural CT assessment of basal IVS thickness is a novel predictive marker for the risk of conduction disturbances following TAVR. The IVS thickness potentially acts as an anatomical barrier protecting the underlying conduction system from mechanical compression during TAVR.


Subject(s)
Aortic Valve Stenosis , Transcatheter Aortic Valve Replacement , Ventricular Septum , Humans , Male , Female , Transcatheter Aortic Valve Replacement/adverse effects , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/diagnostic imaging , Ventricular Septum/diagnostic imaging , Aged, 80 and over , Risk Factors , Aged , Arrhythmias, Cardiac/etiology , Arrhythmias, Cardiac/physiopathology , Arrhythmias, Cardiac/diagnostic imaging , Heart Conduction System/physiopathology , Heart Conduction System/diagnostic imaging , Treatment Outcome , Predictive Value of Tests , Risk Assessment , Severity of Illness Index , Retrospective Studies , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Multidetector Computed Tomography , Tomography, X-Ray Computed , Action Potentials
18.
BMC Cardiovasc Disord ; 24(1): 253, 2024 May 16.
Article in English | MEDLINE | ID: mdl-38750455

ABSTRACT

BACKGROUND: Primary coronary slow flow (CSF) is defined as delayed opacification of the distal epicardial vasculature during coronary angiography in the absence of relevant coronary artery stenoses. Microvascular disease is thought to be the underlying cause of this pathology. Epicardial fat tissue (EFT) is an active endocrine organ directly surrounding the coronary arteries that provides pro-inflammatory factors to the adjacent tissue by paracrine and vasocrine mechanisms. The aim of the present study was to investigate a potential association between EFT and primary CSF and whether EFT can predict the presence of primary CSF. METHODS: Between 2016 and 2017, n = 88 patients with high-grade aortic stenosis who were planned for transcatheter aortic valve implantation (TAVI) were included in this retrospective study. EFT volume was measured by pre-TAVI computed tomography (CT) using dedicated software. The presence of primary CSF was defined based on the TIMI frame count from the pre-TAVI coronary angiograms. RESULTS: Thirty-nine of 88 TAVI patients had CSF (44.3%). EFT volume was markedly higher in patients with CSF (142 ml [IQR 107-180] vs. 113 ml [IQR 89-147]; p = 0.009) and was strongly associated with the presence of CSF (OR 1.012 [95%CI 1.002-1.021]; p = 0.014). After adjustment, EFT volume was still an independent predictor of CSF (OR 1.016 [95%CI 1.004-1.026]; p = 0.009). CONCLUSION: Primary CSF was independently associated with increased EFT volume. Further studies are needed to validate this finding and elucidate whether a causal relationship exists.


Subject(s)
Adipose Tissue , Aortic Valve Stenosis , Coronary Angiography , Coronary Circulation , Pericardium , Predictive Value of Tests , Severity of Illness Index , Transcatheter Aortic Valve Replacement , Humans , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/physiopathology , Aortic Valve Stenosis/diagnostic imaging , Female , Male , Retrospective Studies , Pericardium/diagnostic imaging , Transcatheter Aortic Valve Replacement/adverse effects , Aged , Adipose Tissue/diagnostic imaging , Adipose Tissue/physiopathology , Aged, 80 and over , Risk Factors , Treatment Outcome , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Aortic Valve/pathology , Computed Tomography Angiography , Coronary Vessels/diagnostic imaging , Coronary Vessels/physiopathology , Epicardial Adipose Tissue
19.
Trials ; 25(1): 324, 2024 May 16.
Article in English | MEDLINE | ID: mdl-38755709

ABSTRACT

BACKGROUND: The optimal antithrombotic strategy early after aortic valve replacement surgery with a biological valve remains controversial due to lack of high-quality evidence. Either oral anticoagulants or acetylsalicylic acid should be considered for the first 3 months. Hypo-attenuated leaflet thickening on cardiac computed tomography has been associated with latent bioprosthetic valve thrombosis and may be prevented with anticoagulation. We hypothesize that anticoagulation with apixaban is superior to single antiplatelet therapy with acetylsalicylic acid in reducing hypo-attenuated leaflet thickening of bioprosthetic aortic valve prostheses. METHODS: In this prospective, open-label, randomized trial, patients undergoing isolated aortic valve replacement surgery with rapid deployment bioprosthetic valves will be randomized. The treatment group will receive 5 mg of apixaban twice a day for the first 3 months and 100 mg of acetylsalicylic acid thereafter. The control group will be administered 100 mg of acetylsalicylic acid once a day, indefinitely. After the 3-month treatment period, a contrast-enhanced electrocardiogram-gated cardiac computed tomography will be performed to identify hypo-attenuated leaflet thickening of the bioprosthetic valve. The primary objective of the study is to assess the impact of apixaban on the prevention of hypo-attenuated leaflet thickening at 3 months. The secondary and exploratory endpoints will be clinical outcomes and safety profiles of the two strategies. DISCUSSION: Antithrombotic therapy after aortic valve replacement is used to prevent valve thrombosis and systemic thromboembolism. Latent bioprosthetic valve thrombosis is a precursor of clinically significant prosthetic valve dysfunction or thromboembolic events. The hallmark feature of latent bioprosthetic valve thrombosis is hypo-attenuated leaflet thickening on cardiac computed tomography. Subclinical leaflet thrombosis occurs frequently in bioprosthetic aortic valves, more commonly in transcatheter than in surgical valves. There is no evidence on the effect of direct oral anticoagulants on the incidence of hypo-attenuated leaflet thickening after surgical aortic valve replacement with rapid deployment bioprostheses. TRIAL REGISTRATION: ClinicalTrials.gov NCT06184113. Registered on December 28, 2023.


Subject(s)
Aortic Valve , Aspirin , Bioprosthesis , Factor Xa Inhibitors , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Pyrazoles , Pyridones , Randomized Controlled Trials as Topic , Thrombosis , Humans , Aspirin/administration & dosage , Aspirin/therapeutic use , Aspirin/adverse effects , Pyridones/therapeutic use , Pyridones/administration & dosage , Pyridones/adverse effects , Prospective Studies , Heart Valve Prosthesis/adverse effects , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Thrombosis/prevention & control , Thrombosis/etiology , Pyrazoles/therapeutic use , Pyrazoles/administration & dosage , Pyrazoles/adverse effects , Factor Xa Inhibitors/administration & dosage , Factor Xa Inhibitors/adverse effects , Factor Xa Inhibitors/therapeutic use , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis Implantation/methods , Treatment Outcome , Platelet Aggregation Inhibitors/administration & dosage , Platelet Aggregation Inhibitors/therapeutic use , Platelet Aggregation Inhibitors/adverse effects , Female , Male , Middle Aged , Time Factors , Aged , Adult , Fibrinolytic Agents/administration & dosage , Fibrinolytic Agents/adverse effects
20.
Comput Biol Med ; 177: 108608, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38796880

ABSTRACT

BACKGROUND AND OBJECTIVE: Cardiac computed tomography angiography (CTA) is the preferred modality for preoperative planning in aortic valve stenosis. However, it cannot provide essential functional hemodynamic data, specifically the mean transvalvular pressure gradient (MPG). This study aims to introduce a computational fluid dynamics (CFD) approach for MPG quantification using cardiac CTA, enhancing its diagnostic value. METHODS: Twenty patients underwent echocardiography, cardiac CTA, and invasive catheterization for pressure measurements. Cardiac CTA employed retrospective electrocardiographic gating to capture multi-phase data throughout the cardiac cycle. We segmented the region of interest based on mid-systolic phase cardiac CTA images. Then, we computed the average flow velocity into the aorta as the inlet boundary condition, using variations in end-diastolic and end-systolic left ventricular volume. Finally, we conducted CFD simulations using a steady-state model to obtain pressure distribution within the computational domain, allowing for the derivation of MPG. RESULTS: The mean value of MPG, measured via invasive catheterization (MPGInv), echocardiography (MPGEcho), and cardiac CTA (MPGCT), were 51.3 ± 28.4 mmHg, 44.8 ± 19.5 mmHg, and 55.8 ± 25.6 mmHg, respectively. In comparison to MPGInv, MPGCT exhibited a higher correlation of 0.91, surpassing that of MPGEcho, which was 0.82. Moreover, the limits of agreement for MPGCT ranged from -27.7 to 18.7, outperforming MPGEcho, which ranged from -40.1 to 18.0. CONCLUSIONS: The proposed method based on cardiac CTA enables the evaluation of MPG for aortic valve stenosis patients. In future clinical practice, a single cardiac CTA examination can comprehensively assess both the anatomical and functional hemodynamic aspects of aortic valve disease.


Subject(s)
Computed Tomography Angiography , Hemodynamics , Humans , Computed Tomography Angiography/methods , Male , Female , Aged , Hemodynamics/physiology , Middle Aged , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Aortic Valve Disease/diagnostic imaging , Aortic Valve Disease/physiopathology , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/physiopathology , Models, Cardiovascular , Echocardiography/methods
SELECTION OF CITATIONS
SEARCH DETAIL
...